0% found this document useful (0 votes)
222 views1 page

API-650 Tank Design Specifications

The document provides design data for an above ground storage tank including a nominal diameter of 8,000 mm, height of 7,200 mm, design liquid level of 7,200 mm, maximum capacity of 361.9 m3, and material of construction including a shell of 36 mm thick A36 steel and a bottom/roof plate of 106 mm thick A36 steel. The tank will store potable water at operating temperatures up to 55°C and is located in a seismic zone II area with a design wind speed of 190 km/hr.

Uploaded by

Wh Ng
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
222 views1 page

API-650 Tank Design Specifications

The document provides design data for an above ground storage tank including a nominal diameter of 8,000 mm, height of 7,200 mm, design liquid level of 7,200 mm, maximum capacity of 361.9 m3, and material of construction including a shell of 36 mm thick A36 steel and a bottom/roof plate of 106 mm thick A36 steel. The tank will store potable water at operating temperatures up to 55°C and is located in a seismic zone II area with a design wind speed of 190 km/hr.

Uploaded by

Wh Ng
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

DESIGN DATA Design Code API-650 11TH ED. JUNE 2007 Addendum-1, Nov.

2008 Applicable Appendix Basic Design & App. E NO Appendix M applicable Tank nominal diameter (Uncorroded) D 8000 mm Tank height Ht 7200 mm Min. Filling Level Hmin 500 mm Normal Filling Level 7200 mm Design liquid Level 7200 mm Maximum capacity of Tank Cl.5.2.6.2 361.9 m3 Net working capacity Cl.5.2.6.3 255.0 m3 Design temperature Td (max) 55.0 C Min. Design Metal Temp. Td (min) 0.0 C Design pressure Pi 0.0 mm wc Minimum Vacuum pressure Cl.5.2.1b Pv 25.0 mm wc Is it internal foating Roof with Circulation vent NO Vacuum pressure 25.0 mm wc Design Vacuum pressure 25.0 mm wc Operating pressure atmospheric Po 0.0 mm wc Operating temperature max. To 55.0 C Fluid handled Potable water Specific gravity G 1.0 Primary Design Liquid Column Ho 7200 mm Hydrotest Liquid Column Hoh 7200 mm Hydrotest temperature Tht 40.0 C Design Snow load Sw 0.0 KPa Min. Design Wind Speed Cl.5.2.1K 190 km/hr Actual site wind speed 160 km/hr Topography factor S1 1.0 Ground Roughness S2 1.1 Statistical factor S3 1.0 Seismic Calculation As per App. E Seismic Zone II Max. Pumping Rate In 130.0 m3/hr Out 342.0 m3/hr Insulation thickness NIL 0 mm Density of insulation Material 0 Kg/m3 Radiography As per Section 8 & Fig. 8.1 of API 650 Corrosion allowance (Bottom) 1.6 mm Corrosion allowance (Shell & Internals) 1.6 mm Corrosion allowance (Roof & Structural) 1.0 mm MATERIAL OF CONSTRUCTION Shell All courses Bottom / Roof Plate Roof structure/Compression Ring Nozzle Pipes Nozzle Flanges Manhole Neck and Cover Bolting for nozzle Bolting for manhole External attachments / pads Anchor Bolt

A A A A A A A A A A

36 36 36 106 Gr B 105 36 193 Gr B7/A 194 Gr 2H 193 Gr B7/A 194 Gr 2H 36 307

You might also like