0% found this document useful (0 votes)
624 views1 page

Grating Design Calculations and Parameters

The document provides design parameters for a welded and press locked grating including the thickness and depth of the bearing bars, center to center distance between bars, number of bars per meter, material properties, and calculations for section modulus, moment of inertia, maximum bending moment and load, and deflection. It evaluates two load cases - a concentrated load at the center and uniform distributed load - and determines that the actual loads are less than the maximum allowable loads based on the material properties so the grating is safe for bending.

Uploaded by

garateta
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
624 views1 page

Grating Design Calculations and Parameters

The document provides design parameters for a welded and press locked grating including the thickness and depth of the bearing bars, center to center distance between bars, number of bars per meter, material properties, and calculations for section modulus, moment of inertia, maximum bending moment and load, and deflection. It evaluates two load cases - a concentrated load at the center and uniform distributed load - and determines that the actual loads are less than the maximum allowable loads based on the material properties so the grating is safe for bending.

Uploaded by

garateta
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Design Nomenclature for grating Thickness of reactangular Bearing Bar(b) Depth of Bearing Bar(d) Center to center distance Between

Bearing Bar in welded & press locked grating (Aw) Number of Bearing Bar per meter grating width (K) Allowable yield stress for SS316L grating (F) Modulus of Elesticity (E)

= =

5 30

mm mm

= = = = = =

30 33 170 170000 200000 200000000

mm nos N/mm2 KN/m2 N/mm2 KN/m2

Section Modulus of grating per meter width (Sw) = Kbd^2/6

0.00002475

m3

Moment of Interia of garing per meter width (Iw) = Kbd^3/12 Maximum Unstiffening Span length (L) Maximum Bending Moment for grating per meter of width (Mw)=F*Sw Design For Load case 1 - Concentrated Load at Center Maximum Bending Moment (Mw) = PL/4

= =

3.7125E-07 1

m4 m

4.2075

KN-m

so Maximum allowable concentrated load on grating per meter(P) = 4 Mw / L = 16.83 Actual concentrated load on grating are (P) actual = 4.5 So Actual laod P(actual) < Max.Allowable load , so grating are safe in Bending as per Table 1 of SAES-M-001 Maximum bending deflection due to actual concentrated load (DL) = PL^3 / 48EI

KN KN

= =

1.263E-03 1.26

mtr mm

Design For Case 2 - Uniform Distributed Load over 1m^2 span Maximum Bending Moment (Mw) = wl^2 / 8 So maximum allowable uniform load on grating per meter sq. w= [(Mw*8)/l^2 ]/l Actual Distributed load on grating are (P) actual per meter sq.

= =

33.66 3.6

KN/m2 KN/m2

So Actual laod P(actual) < Max.Allowable load , so grating are safe in Bending as per Table 1 of SAES-M-001 Maximum bending deflection due to actual uniform load (DL) = 5PL^4 / 384EI

= =

6.3131E-04 0.63

mtr mm

You might also like