ICS-100 ICS-102 ICS102-S15
RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter
Key Features
SerIAL INTerFAce
One RS-232/422/485 port to one 10/100Base-TX or 100Base-FX Media Converter Cost effective solution for RS-232 to Ethernet application Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation Asynchronous serial data rates up to 921600b/s
Cost effective solution for RS-232 / RS-422 / RS-485 to Ethernet application PLANET ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485 communication interface over Fast Ethernet networking. There are RJ-45 and SC connectors and singlemode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily, efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET Media Converter Chassis (MC-700, MC-1000 and MC-1500). Its time saving expense for user and SI, no need to replace the existing Serial equipment and software system. Extend distance It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of distance are provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable and efficient network solutions based on the distance and budgets of installation. Remote Manageable The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a TCP/IP networking immediately. Each Web-Smart converter is able to manage Web Interface. The powerful Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc. It helps reduce the amount of valuable time that a network administrator spends detecting and locating network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection options for large networking environment are available as well.
ETHerNeT INTerFAce
Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX standard Supports auto MDI/MDI-X function on RJ-45 Port Choice of ber-connector from SC, multi-mode / single-mode ber
SmArT FUNcTIONs
Standard TCP/IP interface and versatile operation modes Software Protocol Support ARP, ICMP, TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client Built-in IP-Base Web interface for remote management Serial Operation mode selected via Web management Pair Connection mode for connecting two serial devices over a network PLANET Smart Discovery utility automatically nds xxx devices on the network Firmware upgrade via HTTP protocol
HArDWAre
Compact size for easy Installation: > Standalone - Wall mountable or DIN-Rail mounting (Optional accessory) > Co-work with PLANET MC family Media Chassis ( MC700/1000R/1500) LED indicators for easy network diagnose Reset Button at the front panel for reset to factory default
Data Sheet
1
ICS-100 ICS-102 ICS-102S15
Applications
Access Control System traditional installation
Most of the enterprise and government use access control plate and Mifare or RFID to authorize entrance identity. With traditional deploy, access control machine use RS-232 or RS-485 serial interface and cables connect to login server. With connection to ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extend over longer distances via ber optical interface. The distance can be up to 20km in a local range. Or the ICS10x can be linked to a XDSL router to get the internet access capability; the access control can be set and monitored over the internet.
Process Control
To m o n i t o r, c o n f i g u re a n d m a n a g e t h e Robot conveyer including other machines in manufacturing, PLC (Programmable Logical Control) is required. The PLC is used to drive above the manufacturing process. The ICS-10x can be set to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast Ethernet intranet to control the PLC, the administrator and workstation. There is no need to be always by the side of the I/O machine.
RTU Data Collect UDP Mode
Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, signal and power utilization. ICS-10x can be used setup UDP mode and send data over Fast Ethernet to Local server or over internet to remote server automatically.
Surveillance motion control Pair Connection Mode
Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232 / RS-422 / RS-485 interfaces distance from surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.
Data Sheet
2
11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel: 886-2-2219-9518 Fax: 886-2-2219-9528 Email: sales@[Link] [Link] VoIP Gateway: [Link]
PLANET Technology Corporation
PLANET reserves the right to change specifications without prior notice. All brand names and trademarks are property of their respective owners. Copyright 2008 PLANET Technology Corp. All rights reserved.
Specification
Product
Model Serial Port Interface Connector Baud rate (Data Rate) Data Bits Stop Bit Flow Control Signals Fast Ethernet Port Standard Connector Mode Distance Optical Wavelength Cable Protection Hardware LED Indicators
ICS-100 ICS-102 ICS-102S15
RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter
ICS-100 ICS-102 ICS-102S15
RS-232 / RS-422 / RS-485 3-in-1 DB9 110bps to 921K bps 5,6,7,8 1,2 None, RTS/CTS, Xon/Xoff RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS-422: Tx+, Tx-, Rx+, RxRS-485(2-wire): Data+, DataRS-485(4-wire): Tx+, Tx-, Rx+, Rx10/100Base-TX RJ-45 100m Twisted-pair Built-in 1.5KV magnetic isolation System: Power TP or Fiber Port: Link / Active Serial Port: Serial port mode, RS-232, RS-422 or RS-485 Web Management PLANET Smart Discovery Utility VCOM Virtual COM Port TCP Server TCP Client UDP Client Pair Connection 97 x 70 x 26 mm 200g External Power Adaptor 5V DC / 2A max. 5.5 Watts (max) Metal Operating Temperature: 0~50 Degree C Storage Temperature: -10~70 Degree C Operating Humidity: 10%~90% RH Storage Humidity: 5%~90% RH FCC Class A, CE Certication Class A IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX / 100Base-FX EIA/TIA RS-232/422/485 RoHS MC-700 / 1000R / 1500 Reset Button at the rear panel for reset to factory default 100Base-FX SC Single Mode 15km 1310nm 9/125m single-mode cable
Multi-Mode 2km 1300nm 50/125m or 62.5/125m multi-mode ber cable
Management
Operation Mode
Dimension(W x D x H) Weight Power Supply Power Consumption Mechanical Environment Emissions Standards Regulatory Approval Compatible Media Converter Chassis Note.
Data Sheet
3
Ordering Information
ICS-100 ICS-101* ICS-102 ICS-102S15 ICS-105A* (*): RS-232/422/485 over Fast Ethernet Media Converter (RJ-45) 100m RS-232/422/485 over Fast Ethernet Media Converter (ST, MM) 2km RS-232/422/485 over Fast Ethernet Media Converter (SC, MM) 2km RS-232/422/485 over Fast Ethernet Media Converter (SC, SM) 15km RS-232/422/485 over Fast Ethernet Media Converter (SFP) Vary on module Upon by request
ICS-100 ICS-102 ICS-102S15
Accessories
RKE-DIN DIN-Rail Mounting Kit
Available Modules
FT-80x FT-90x FST-80x IFT-802 MC-700 MC-1000R MC-1500 10/100Base-TX to 100Base-FX Fast Ethernet Media Converter 10/100Base-TX to 100Base-FX Web Smart Media Converter 10/100Base-TX to 100Base-FX Fast Ethernet Media Converter Industrial 10/100Base-TX to 100Base-FX Smart Media Converter 10 7-Slot Media Converter Chassis 19 10-Slot Media Converter Chassis (Optional Redundant Power) 19 14-Slot Media Converter Chassis
Data Sheet
4
11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel: 886-2-2219-9518 Fax: 886-2-2219-9528 Email: sales@[Link] [Link] VoIP Gateway: [Link]
PLANET Technology Corporation
04-08
C-ICS10X
PLANET reserves the right to change specifications without prior notice. All brand names and trademarks are property of their respective owners. Copyright 2008 PLANET Technology Corp. All rights reserved.