The hardware models V1280/E2900 etc uses the Lights-out management to manage the hardware. LOM is
a set of software tools on the Sun Fire V1280/E2900 servers. LOM is used to perform user maintenance and
administrative activities.
2 de 14
Show the current network configuration
lom>shownetworkv
To assign an IP address to ILOM
lom>setupnetwork
NetworkConfiguration
Isthesystemcontrolleronanetwork?[no]:yes
UseDHCPorstaticnetworksettings?[DHCP]:static
Hostname[]:somename
IPAddress[]:129.xxx.xxx.xxx
Netmask[255.255.255.0]:255.255.255.0
Gateway[]:129.xxx.xxx.xxx
3 de 14
DNSDomain[]:somewhere.nowhere.com
PrimaryDNSServer[]:129.xxx.xxx.xxx
SecondaryDNSServer[]:129.xxx.xxx.xxx
RebootingtheSCisrequiredforchangesinnetworksettingstotakeeffect.
To login to the OS console from ILOM
lom>console
To logout from the ILOM
lom>logout
To check the current escape character
lom>showescape
#.
To set a new escape character
lom>setescape~.
To set/reset password of the current user
lom>password
Enternewpassword:admin
4 de 14
Enternewpasswordagain:admin
To see all the hardware
lom>showboards
To only see the CPUs
lom>showboardspcpu
To only see the memory modules
lom>showboardspmemory
To only see the power supply units
lom>showboardsppower
To see the version of each individual component
lom>showboardspversion
To see individual component status of a system board
5 de 14
lom>showcomponentsb0
To check the various sensors
lom>showenvironment
To see the logs
lom>showlogs
To poweron the system and boot solaris OS
lom>poweron
To poweron only a specific component
lom>poweronsb2
To shutdown Solaris OS and poweroff the system to standby mode
lom>shutdown
To poweroff the entire system
6 de 14
lom>poweroff
To poweroff a specific hardware component
lom>poweroffsb2
The hardware models Sun Fire 3800, 4800/E4900, 4810, and 6800/E6900 uses the system controller to
manage the hardware components of individual domains that may have been created. So we have 2 login to
a specific domain system controller from platform shell in order to manage the hardware of that domain. The
showplatform command shows all the configured domains on the system.
To check all the domain and platform related information
schostname:SC>showplatformv
7 de 14
To view system controller details
schostname:SC>showscv
To view SC logs
schostname:SC>showlogsv
To view current SC connections
schostname:SC>connections
To reboot a system controller
schostname:SC>reboot
To see all the hardware details of a domain
schostname:SC>showboards
To see only the CPUs in a specific domain
schostname:SC>showboardspcpu
To see only the memory in a specific domain
8 de 14
schostname:SC>showboardspmemory
To see only the power supply unit in a specific domain
schostname:SC>showboardsppower
To see the version of each individual component
schostname:SC>showboardspversion
To see individual component status of a system board
schostname:SC>showcomponentsb0
To start a domain (Domain A)
schostname:A>setkeyswitchon
To stop a domain (Domain A)
schostname:A>setkeyswitchoff
To see the logs of a specific domain (Domain A)
9 de 14
schostname:A>showlogs
To test a CPU/memory board SB0 in domain A
schostname:A>testboardsb0
To reset a domain
schostname:A>reset
To send break to the OS from Domain SC
schostname:A>sendbreak
To flash update the system
schostname:SC>flashupdateyfftp://root:
[email protected]/firmwarescapprtos
Most Commonly used ALOM commands (Cheat Sheet)
Most Commonly used LOM commands (Cheat Sheet)
Most Commonly used ILOM commands (Cheat Sheet)
Most commonly used XSCF commands (Cheat Sheet)
Most Commonly used RSC commands (Cheat sheet)
10 de 14
Filed Under: Hardware
M4000 / M5000 : How to assign IP address to XSCFU
Complete Hardware Reference : SPARC T3-1 / T3-2 / T3-4
Most commonly used XSCF commands (Cheat Sheet)
How to login into console from ILOM, ALOM, LOM, ELOM, XSCF, RSC
How to collect XSCF snapshot on M-series servers (M3000 / M4000 / M5000 / M8000 / M9000)
11 de 14
Your email address will not be published. Required fields are marked *
Comment
Name *
Email *
Website
12 de 14
1. LDoms Cheat Sheet
2. SVM Cheat Sheet
3. ZFS cheat sheet
13 de 14
How to move a datafile from file system to ASM
RHEL 7 RHCSA Notes : Create hard and soft
Thegeekdiary
546 Me gusta
links.
CentOS / RHEL 7 : How to boot into Rescue
Mode or Emergency Mode
S el primero de tus amigos en indicar que te gusta esto.
How To Check World Wide Port Names (WWPN)
of Tape Drives Attached to Linux host
India based Unix Admin, Cloud Evangelist and a
14 de 14
Virtualization lover. Read more about me here ...
@patilsandeep911