100% found this document useful (1 vote)
2K views2 pages

BCS 406 - 2

This document provides the results of analyses of a certified reference material called BCS/SS-CRM No. 406/2, which is a low alloy steel. It lists the concentrations of various elements in the material as measured by 12 independent analysts using various analytical techniques. The mean values from all analysts were calculated and certified for carbon, silicon, manganese, phosphorus, sulfur, chromium, molybdenum, nickel, and other elements. Detailed information is given on the analytical methods used by each analyst to determine the concentrations.

Uploaded by

lehdruk7100
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views2 pages

BCS 406 - 2

This document provides the results of analyses of a certified reference material called BCS/SS-CRM No. 406/2, which is a low alloy steel. It lists the concentrations of various elements in the material as measured by 12 independent analysts using various analytical techniques. The mean values from all analysts were calculated and certified for carbon, silicon, manganese, phosphorus, sulfur, chromium, molybdenum, nickel, and other elements. Detailed information is given on the analytical methods used by each analyst to determine the concentrations.

Uploaded by

lehdruk7100
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

MAIN EDITION

BUREAU OF ANALYSED SAMPLES LTD


Directors:-
P.D.RIDSDALE, BSc, FRSC, CEng, MIM, (Chairman)
R.P.MEERES, BA (Oxon), MRSC (Managing) Certificate No. GB94/3993
G.C.FLINTOFT, ACMA

BRITISH CHEMICAL STANDARD CERTIFIED REFERENCE MATERIAL

CERTIFICATE OF ANALYSIS
BCS*/SS§-CRM No. 406/2
LOW ALLOY STEEL
Prepared under rigorous laboratory conditions and, AFTER CERTIFICATION ANALYSIS IN GREAT BRITAIN,
issued by the Bureau of Analysed Samples Ltd.

CO-OPERATING ANALYSTS AND FIRMS


INDEPENDENT ANALYSTS ANALYSTS representing MANUFACTURERS and USERS
1 HAGGAN, F., BSc, AMTAC Laboratories Ltd., Altrincham. 6 AMBROSE, A.D., BSc,
2 HEYWOOD, D., AMet, Pattinson & Stead, Middlesbrough. British Steel Technical, Corby Technical Centre, Corby.
3 KENNEDY, J.S., LRSC BCIRA, Birmingham. 7 DAVIES, T.D., GKN Technology Ltd., Wolverhampton.
4 PAGE-GIBSON, J.E., BSc, CChem, MRSC 8 DYSON, R.,British Steel Technical, Swinden Laboratories, Rotherham.
Ridsdale & Co. Ltd., Middlesbrough. 9 GULLAND, W.S.,
British Steel Technical, Welsh Laboratories, Port Talbot.
GOVERNMENT DEPARTMENT 10 HACON. J., AMet, CEng, FIM,
5 FRYER, R.E.J., BSc, PhD, CChem, MRSC, Rotherham Engineering Steels, Rotherham.
Directorate of Quality Assurance/Technical Support, 10 HANCOCK, R., BMet, CEng, MIM.
M.O.D., Woolwich. Stocksbridge Engineering Steels, Sheffield.
11 SHAW, D.H., Howmet Alloys International, Exeter.

ANALYSES
Mean of 4 values - mass content in %.
Al
Lab No. C Si Mn P S Cr Mo Ni As Cu Pb V Sn
(Total)
1 … … … … … 2.013 0.98 1.62 … 0.012 0.307 0.0003 0.011 …
2 0.176 0.346 0.459 0.0103 … … … … 0.013 … … … … …
3 … … … … … 2.000 0.98 1.66 … 0.011 0.294 0.0001 0.009 0.001
4 0.175 0.338 0.448 0.0096 0.042 2.007 0.98 1.65 0.013 0.011 0.280 0.0002 0.010 0.002
5 0.173 0.346 0.452 … 0.042 … … … … 0.012 … … … …
6 0.172 0.348 0.448 0.0098 0.042 … 0.99 … 0.014 … 0.286 … … …
7 0.175 0.341 0.436 0.0099 0.045 … … … 0.012 … … … … …
8 … … … … … 1.993 1.00 1.63 … 0.012 0.281 0.0001 0.009 0.001
9 0.172 … … … 0.044 1.992 0.93 1.59 … … 0.281 … 0.010 …
10 0.170 0.337 0.448 0.0109 0.042 … … … … … … … … …
11 0.168 0.340 0.438 0.0105 0.042 1.997 0.98 1.60 0.013 … 0.286 0.0001 0.008 0.001
12 … … … … … 2.005 1.00 1.61 … 0.010 0.300 0.0003 0.012 0.001
MM 0.173 0.342 0.447 0.0102 0.043 2.001 0.98 1.62 0.013 0.012 0.289 0.0002 0.010 …
sM 0.003 0.005 0.008 0.0005 0.001 0.008 0.03 0.03 0.001 0.001 0.010 0.0001 0.002 …
sW 0.003 0.005 0.005 0.0008 0.001 0.007 0.01 0.02 0.001 0.001 0.005 0.0001 0.001 …
The above figures are those which each Analyst has decided upon after careful verification
MM: Mean of the intralaboratory means. sM: standard deviation of the intralaboratory means. sW: intralaboratory standard deviation.
Values given above in small italic type are for information only.
The following additional information was supplied:- Analyst No. 4: Co 0.006%; No. 6 : N 0.009%
CERTIFIED VALUES (Cv)
mass content in %
Al
C Si Mn P S Cr Mo Ni As Cu Pb V
(Total)
Cv 0.173 0.342 0.447 0.0102 0.043 2.001 0.98 1.62 0.013 0.012 0.289 0.0002 0.010
C(95%) 0.003 0.004 0.008 0.0006 0.001 0.008 0.02 0.03 0.001 0.001 0.009 0.0001 0.002
t sM
The half width confidence interval C(95%) = where “t”is the appropriate Student’ s t value and “
n”is the number of acceptable mean values
n
For further information regarding the confidence interval for the certified value see ISO Guide 35:1989 section 4.

Page 1 of 2
BCS/SS-CRM No. 406/2 LOW ALLOY STEEL
NOTES ON METHODS USED
CARBON
Analysts Nos. 2 and 4 determined carbon by non-aqueous titration according to the British Standard Carbon Method 4*. Nos. 5, 6, 7, 10 and 11 used high
frequency combustion/infrared absorption. No. 9 determined carbon coulometrically (Boniface and Jenkins, Analyst, 1971, 96, 37).
SILICON
Analysts Nos. 2, 4, 6, 10 and 11 determined silicon gravimetrically by double dehydration with perchloric acid, according to the British Standard Silicon Method
1*. Nos. 5 and 7 used molybdenum blue photometric methods.
MANGANESE
Analysts Nos. 2 and 7 determined manganese by Flame Atomic Absorption Spectrometry (FAAS). Nos. 4, 5 and 10 determined manganese photometrically,
Nos. 4 and 5 after oxidation with potassium periodate according to the British Standard Manganese Method 2*, No. 10 after oxidation with ammonium persulphate.
Nos. 6 and 11 used Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES).
PHOSPHORUS
All Analysts, except Nos. 6 and 11, determined phosphorus photometrically as phosphovanadomolybdate according to BS 6200:3.24.1:1985 (British Standard
Phosphorus Method 2*). Nos. 6 and 11 used ICP-OES
SULPHUR
Analyst No. 4 determined sulphur gravimetrically according to the British Standard Sulphur Method 1*. Nos. 5, 6, 7, 10 and 11 used high frequency
combustion/infrared absorption. No. 9 determined sulphur coulometrically.
CHROMIUM
Analysts Nos. 1, 3, 4, 8, 9 and 12 determined chromium titrimetrically with ammonium ferrous sulphate after oxidation with persulphate/silver nitrate. Nos. 1, 8,
9 and 12 followed the procedure of BS 6200:3.10.1:1985, No. 3 the procedure in BCIRA Method A‡ and No. 4 that of Analoid Method No. 37. No. 11 determined
chromium by FAAS.
Analyst No. 8 also determined chromium by FAAS and obtained a mean value of 1.997%
Analyst No. 11 also used ICP-OES and obtained a mean value of 1.977%
MOLYBDENUM
Analysts Nos. 1, 3, 4, 8 and 12 determined molybdenum photometrically as oxythiocyanate, No. 3 according to the BCIRA Method B‡ and Nos. 4 and 8
according to the British Standard Molybdenum Method 1*. Nos. 6, 9, and 11 used ICP-OES.
Analyst No. 8 also determined molybdenum by FAAS and obtained a mean value of 0.97%
NICKEL
Analyst No. 1 determined nickel photometrically according to the British Standard Nickel Method 3*. Nos. 3, 4, 8 and 12 determined nickel titrimetrically after
separation with dimethylglyoxime. Nos. 3 and 8 titrated with EDTA. No. 4 dissolved the precipitate in dilute sulphuric acid, boiled with an excess of ferric sulphate
and titrated with potassium dichromate (Analoid Method No. 62). No. 12 titrated nickel cyanometrically according to the British Standard Method 1*. No. 9 used ICP-
OES and No. 11 used FAAS.
Analyst No. 8 also used FAAS and obtained a mean value of 1.62%.
Analyst No. 11 also used ICP-OES and obtained a mean value of 1.60%.
ALUMINIUM (Total)
Analysts Nos. 2, 4, 6 and 7 determined aluminium uising FAAS, Nos. 6 and 7 used an injection technique. No. 11 used ICP-OES.
ARSENIC
Analysts Nos. 1 and 4 determined arsenic photometrically with silver diethyldithiocarbamate after separation of arsenic as arsine by reduction with zinc. No. 3
determined arsenic iodometrically according to the British Standard Arsenic Method 1*. Nos. 5 and 12 used Electrothermal Atomisation-Atomic Absorption
Spectroscopy (ETA-AAS) and No. 8 used FAAS.
COPPER
Analysts Nos. 1, 8 and 12 determined copper by FAAS. Nos. 3 and 4 determined copper photometrically, No. 3 with 2,2′ -diqunnolyly according to BCIRA
Method C‡, No. 4 with bis-cyclohexanone oxalyldihydrazone according to the Analoid Method No. 65. Nos. 6, 9 and 11 used ICP-OES.
Analyst No. 11 also used FAAS and obtained a mean value of 0.280%.
LEAD
All Analysts except Nos. 3 and 12 used FAAS, No.4 made a prior separation of lead with tri-n-octylphosphine oxide and 4-methylpetan-2-one. Analysts Nos. 3
and 12 used ETA-AAS.
VANADIUM
Analysts Nos. 1 and 8 determined vanadium by FAAS. Nos. 3, 9, 11 and 12 used ICP-OES. No.4 determined vanadium photometrically as vanadotungstate
according to the Analoid method No. 59, after carrying out a prior separation of iron by ether extraction.
Tin
Analysts Nos. 3 and 12 determined tin by ETA-AAS. Nos. 4 and 8 used FAAS, No. 4 made a prior separation with of tin with tri-n-octylphosphine oxide and 4-methypentan-2one. No.
11 used ICP-OES.

*Methods for Sampling and Analysis of Iron, Steel and other Ferrous Metals, B.S. Handbook No. 19, published 1970 by the British Standards Institute, London.

Chemical Analysis for Iron Foundries, published 1976 by BCIRA.
DESCRIPTION OF SAMPLE
*British Chemical Standard –bottles of 100g chips graded 1700 –250µm (10 –60 mesh) for chemical analysis.
§ Spectroscopic Standard –38 mm diameter discs for spectroscopic analysis
INTENDED USE & STABILITY
The chip sample, BCS-CRM 406/2, is intended for the verification of analytical methods, such as those used by the participating laboratories, for the calibration of
analytical instruments in cases where the calibration with primary substances (pure metals or stoichiometric compounds) is not possible and for establishing values for
secondary reference materials.
It will remain stable provided that the bottle remains sealed and is stored in a cool, dry atmosphere. When the bottle has been opened the lid should be secured
immediately after use. If the contents should become discoloured (e.g. oxidised) by atmospheric contamination they should be discarded.
The disc sample, SS-CRM 406/2, is intended for establishing and checking the calibration of Optical Emission and X-Ray Spectrometers for the analysis of similar
materials. The “as received”working surface of the sample should be linished before use to remove any protective coating. It will remain stable provided that it is not
subject to excessive heat (e.g., during preparation of the working surface). An area 6mm in diameter in the centre of the disc should be avoided for optical emission
spectrometry
TRACEABILITY
The traceability of this CRM is ensured by the use of either stoichiometric analytical techniques or methods which are calibrated against pure metals or stoichiometric
compounds.
This Certified Reference Material has been prepared in accordance with the recommendations specified in ISO Guides 30 to 35, available from the International
Standards Organisation in Geneva.
NEWHAM HALL, NEWBY, For BUREAU OF ANALYSED SAMPLES LTD
MIDDLESBROUGH, ENGLAND, TS8 9EA
Email: [email protected] P.D. RIDSDALE,
Website: www.basrid.co.uk Chairman
Preliminary Edition …. .… …. …. … …. …. …. …. …. …. …. …. …. …. …. .… …. …. …. …. …. …. …. …. …. …. July 1990
Main Edition …. .… …. …. …. …. …. …. …. …. …. …. …. …. …. …. …. .… …. …. …. …. …. …. …. …. …. …. July 1991
Revised with C(95%) and sW values for each certified element …. …. …. …. …. …. …. …. …. .… …. …. …. …. …. …. …. …. …. …. February 2006

Page 2 of 2

You might also like