icountPD

Online Particle Detector


For mineral oil, aggressive fluids or fuels
(ATEX approved version available. See page 476)

Independent
monitoring of system
contamination trends
The icountPD Particle Detector
from Parker represents the most
up to date technology in particle
detection. The design dynamics,
attention to detail and moulding
compactness of the permanently
mounted, on-line particle detector
module, combined with on-board,
laser based, leading-edge
technology, brings to all industries a
truly revolutionary, particle detector
as a remarkable cost effective
market solution to fluid management
and contamination control.

icountPD for mineral oil applications

Contact Information: Product Features:


Parker Hannifin
• Independent monitoring of • Continuous performance for
Hydraulic Filter Division Europe
system contamination trends. prolonged analysis.
• Warning LED or digital display • Fuel, Hydraulic and phosphate
European Product indicators for Low, Medium Ester fluid compatible
Information Centre and High contamination levels. construction.
Freephone: 00800 27 27 5374 • Visual indicators with power • Self diagnostic software.
(from AT, BE, CH, CZ, DE, EE, ES, and alarm output warnings.
FI, FR, IE, IT, PT, SE, SK, UK) • Full PC/PLC integration
filtrationinfo@[Link] • Moisture %RH indicator technology such as:- RS232
(optional). and 0-5Volt, 4-20mA,
[Link]/hfde • Cost effective solution to CAN(J1939) (Contact Parker
prolong fluid life and reduce for other options).
machine downtime. • Set up and Data logging
• MI2 8 pin or Deutsch support software included.
Connector options.

Parker Hannifin
Hydraulic Filter Division Europe
436 FDHB500UK/icountPD
icountPD
Online Particle Detector
Features & Benefits
Diagnostic Self Check Start-up Time: Online Flow Range via System 20 Inline Sensors (Hydraulic
Customer selectable 5-900 seconds systems only):
Measurement Period: Size 0 = 6 to 25 l/min - (Optimum Flow = 15 l/min)
5 to 180 seconds Size 1 = 24 to 100 l/min - (Optimum Flow = 70 l/min)
Reporting interval through RS232: Size 2 = 170 to 380 l/min - (Optimum Flow = 250 l/min)
0 to 3600 seconds Required Differential Pressure across Inline Sensors:
Digital -/LED display update time: 0.4 bar (Minimum)
Every second Viscosity Range:
Limit Relay Output: 1-500 cSt
Changes occur +/- 1 ISO code at set limit (Hysteresis ON) or customer Temperature:
set (Hysteresis OFF) Ambient storage temperature -20°C to +40°C (-4°F to +104°F)
Particle / % RH Output Signal: Environment operating temperature +5°C to +60°C (+41°F to +140°F)
Continuous Fluid operating temperature +5°C to +80°C (+41°F to +176°F)
Principle of operation: Working pressure:
Laser diode optical detection of actual particulates 2 to 420 bar (30-6000 PSI)
International Codes: Moisture sensor calibration (Not offered with the fuel version):
ISO 7 – 22, NAS 0 – 12 ±5% RH (over compensated temperature range of +10°C to +80°C)
Calibration: (+50°F to +176°F)
By recognised online methods confirmed by the relevant ISO proce- Operating humidity range:
dures 5% RH to 100% RH
MTD – Via a certified primary ISO 11171 automatic particle detector Moisture sensor stability:
using ISO 11943 principles, with particle distribution reporting to ISO ±0.2% RH typical at 50% RH in one year
4406:1996 Certification:
ACFTD – Conforming to ISO 4402 principles with particle distribution IP66 rated. Refer to the EC Declaration of Conformity.
reporting to ISO 4406:1996 EMC/RFI – EN61000-6-2:2001
Recalibration: EN61000-6-3:2001
Contact Parker Hannifin Materials:
Performance: User friendly Abs construction.
+/- 1 ISO Code (Dependant on stability of flow) Stainless Steel hydraulic block.
Reproducibility / Repeatability: Dimensions:
Better than 1 ISO Code 182mm x 155mm x 86mm (7.2” x 6.1” x 3.4”)
Power Requirement: Weight:
Regulated 9 to 40Vdc 1.3kg (2.9lb)
Current Rating: Seals:
Typically 120mA Mineral: Fluorocarbon. Aggressive: EPDM. Fuel: Fluorocarbon.
Hydraulic Connection: Computer Compability:
Mineral M16x2 test Points Parker recommends the use of a 9-way D-type connector. This can be
Aggressive: 5/8” BSF test Points connected to a USB port using a USB-serial adaptor. Note that these
Fuel: No test Points 1/8 BSP (Female) Ports (Plugged) connectors/adaptors are NOT supplied with icountPD units: contact
Required Flow Range through the icountPD: Parker Hannifin for advice.
40 to 140 ml/min (Optimum Flow = 60ml/min)

icountPD for use with aviation fuels


Field Data - Major International Airport
First 3 measurements represent fuel >4µ >6µ >14µ >21µ >4µ >6µ >14µ >21µ
from a previous cargo followed by a Test 1 81058.3 62126.1 17817.6 6066.2 Test 5 1226.1 261.5 2.4 0.4
regular clean delivery, thus demonstrating Test 2 87834.5 74763.0 35454.1 18044.4 Test 6 1085.7 210.9 1.3 0.1
the range of fuel cleanliness being Test 3 51383.4 32796.9 4424.8 1213.4 Test 7 1037.9 198.7 1.3 0.1
experienced at this particular location. Test 4 1593.3 422.7 9.6 1.7

icountPD for use with aviation fuels

Parker Hannifin
Hydraulic Filter Division Europe
437 FDHB500UK/icountPD
Dimensions / Installation Details

Maximum Torque 5Nm

Typical Applications
Mobile Equipment Power Generation
o Earth Moving Machinery o Wind Turbines
o Harvesting o Gearboxes
o Forestry o Lubrication Systems
o Agriculture With continuous monitoring the optimum level is
Monitoring of the hydraulics, enabling the vehicles achieved in the least amount of time.
to function to their best capability under load
conditions through pistons, servo valves, control Maintenance
rams and gear pumps.
o Test Rigs
o Flushing Stands
Industrial Equipment
To increase efficiency of your equipment by
o Production Plants continuously monitoring the cleanliness level of the
o Fluid Transfers hydraulic fluid.
o Pulp & Paper
o Refineries Fuel Contamination Detection
To monitor the cleanliness of the equipment o Fuel Storage Tanks
throughout the production line, from the machine o Vehicle fuel tanks
tool controlled hydraulics through to contamination
o Uploading fuel into an aircraft
of fluid transfer. Ensuring the integrity of the fluid is
maintained throughout the refining process. 24/7 detection of particulate levels in most fuels
including aviation fuel - Jet A-1 fuel specification.
Parker Hannifin
Hydraulic Filter Division Europe
438 FDHB500UK/icountPD
Variable mA output settings

ISO V Output mA The following table can be used to equate the analogue
20.0 output to an ISO or NAS Code.
18.0
Example ISO code 12 is equal to 10mA
16.0
Milliamp Output

14.0 mA ISO mA NAS


12.0 4.0 0 4 00
10.0 4.5 1 5 0
8.0 5.0 2 6 1
6.0 5.5 3 7 2
4.0 6.0 4 8 3
2.0 6.5 5 9 4
7.0 6 10 5
0.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 7.5 7 11 6
ISO CODE 8.0 8 12 7
8.5 9 13 8
9.0 10 14 9
NAS V Output mA 9.5 11 15 10
20 10.0 12 16 11
18 10.5 13 17 12
16 11.0 14 18 **
Milliamp Output

14 11.5 15 19 **
12.0 16 20 ERROR
12
12.5 17
10
13.0 18 The following table can be used to equate the
8 13.5 19 analogue output to an ISO or NAS Code.
6 14.0 20
4 14.5 21 Example ISO code 12 is equal to 10mA
2 15.0 **
0 15.5 ** 4-20mA output settings
0 1 2 3 4 5 6 7 8 9 10 11 12 13
16.0 **
NAS CODE ISO Setting
16.5 **
mA current = (ISO Code / 2) +4 eg. 10mA = (ISO 12 / 2) +4
17.0 **
or
17.5 **
ISO Code = (mA current - 4) *2 eg. ISO 12 = (10mA -4) *2
18.0 **
18.5 ** NAS Setting
19.0 OVERRANGE mA current = NAS Code +5 eg. 15mA = NAS 10 +5
19.5 OVERRANGE or
Variable voltage output settings 20.0 ERROR NAS Code = mA current -5 eg. NAS 10 = 15mA – 5

The variable voltage output option has the capability of two different voltage ranges: a 0–5Vdc range as
standard, and a user-selectable 0–3Vdc range. The ‘Full list of commands’ on how to change the voltage
output, are available from Parker.
The following tables can be used to relate the analogue ouptut to an ISO or NAS code.
For example, in a 0–5Vdc range, ISO code 16 is equal to an output of 3.5Vdc. In a 0–3Vdc range, ISO code 8
is equal to an output of 1.0Vdc.
Table relating ISO codes to Voltage output
ISO Err 0 1 2 3 4 5 6 7 8 9 10 11 >
0–5Vdc <0.2 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5
0–3Vdc <0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3

cont. ISO 12 13 14 15 16 17 18 19 20 21 22 Err


0–5Vdc 2.7 2.9 3.1 3.3 3.5 3.7 3.9 4.1 4.3 4.5 4.7 >4.8
0–3Vdc 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 >2.45

Table relating NAS codes to Voltage output


NAS Err 00 0 1 2 3 4 5 6 7 8 9 10 11 12 Err
0–5Vdc <0.4 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 >4.6
0–3Vdc <0.2 N.S. 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 2.7 >2.8

Parker Hannifin
Hydraulic Filter Division Europe
439 FDHB500UK/icountPD
icountPD
Online Particle Detector

Digital display parameters (ISO 4406/NAS 1638)

Start up
1. Once the icountPD has been connected to a regulated power supply, the product logo is displayed for
approximately five seconds as the icountPD performs a self system diagnostic check.
2. The icountPD then automatically starts monitoring using factory default test parameters.

(c) MTD calibrated


Channel sizes/Limits Measured ISO codes
%RH Moisture sensor reading
Automatic light sensor

Notes: ISO 17/16/14 and


MS = 43% RH if fitted

Digital display indication


The digital display will show the actual measured codes, the channel (µ) size and the user definable limits.
Note that the channel size and limits are displayed alternately.
The Moisture Sensor reading (%RH) will also be shown – if the Moisture Sensor option is fitted.
The order of trigger for both the codes and Moisture Sensor option is:
• Solid digit(s) = code(s) that are at or below the set point (limit)
• Flashing digit(s) = code(s) that are above the set point (limit)
The display for ISO4406 and NAS1638 are identical.

Error detection:
In the unlikely event of a error occurring, the digital display on the icountPD will simply display the actual
error code only – i.e. ERROR 13 (A full list of error codes are detailed in the icountPD User Manual).

Moisture sensor output settings


The Moisture Sensor is an option that can be included when ordering the icountPD.
The Moisture Sensor reports on the saturation levels of the fluid passing through the icountPD sensing cell.
The output is a linear scale, reporting within the range of 5% saturation to 100% saturation.

Table relating Saturation levels in the sensing cell to icountPD outputs


Saturation 4–20mA 0–3Vdc 0–5Vdc
5% 4.8 0.15 0.25
25% 8 0.75 1.25
50% 12 1.50 2.50
75% 16 2.25 3.75
100% 20 3.00 5.00

Parker Hannifin
Hydraulic Filter Division Europe
440 FDHB500UK/icountPD
Flow control ACC6NN019

A pressure compensated, flow control device


(Parker Hannifin part number ACC6NN019)
has been develop to give the icount PD greater
flexibility.
The flow control device enables testing where flow
ranges are out side the icountPD specification i.e.
(40 – 140 ml/min), or where pipe diameters do not
allow the icountPD to be installed.
P/N ACC6NN019
The flow control device fits onto the downstream
(outlet) side of the icountPD. A 06L EO 24 deg
cone and hydraulic adaptor is supplied which
enables connection directly to the icountPD.
Alternatively the flow control device can be fitted
further down stream.
The compact design requires no setting up or
Working pressure range 10 to 300 bar
further user intervention as long as the system
conditions remain within the recommended Differential pressure range 10 to 300 bar

pressure and viscosity ranges as below. Working viscosity range 10 to 150 Cst

icountOS – Oil Sampler (IOS)


• New and under development in the detection of
contaminates distribution in various Aviation fuels.
• Portable monitoring tool providing fluid
qualification to ISO 4406:1999 standards.
• Supplements the icount LCM20 and ACM20
product portfolio.
• Quick, simple to use monitoring tool for sampling
fluids from containers, fuel bunkers and holding
tanks.
• Field solution to Laboratory methods for the
detection of solid contamination and free water
inference.

Parker Hannifin
Hydraulic Filter Division Europe
441 FDHB500UK/icountPD
icountPD
Online Particle Detector

Hydraulic Connection Diagram Dimensions

icountPD

P2 P1

113.2
58.2

78.2
78.2

20.0
High Pressure
Line Side G1/8 ports either side 46.5 90.0
of mounting block 50.0

“In”

4 holes 6.60 Thro’

80.0 Ctrs
In Out

62.0
Low Pressure

49.2
Return Side
Actuator
“Out”
To Atmosphere
38.0 Ctrs
2 bar check valve

Flow Control Actuator Specification (P/N S840074)


Operation Manual flow rate adjustable via control knob
Mounting Type 4 off mounting holes to suit M6 screws (not supplied)
Mounting position Any
Weight 1.7kg (3.7lb)
Fluid Temperature 5°C to +80°C (+41°F to 176°F)
Ambient storage temperature -20°C to +40°C (-4°F to +104°F)
Viscosity range 20cSt to 500cSt (If lower than 20cSt contact Parker)
Differential pressure range 5 to 315 bar
Maximum pressure 315 bar
Flow direction ‘IN’ to ‘OUT’ flow control function
Port thread detail 1/8” BSPP (test points not supplied)
Internal Seals Fluoroelastomer

This application shows uploading


fuel into an aircraft with the
icountPD in use to monitor as a
‘go/no go’ device.

Parker Hannifin
Hydraulic Filter Division Europe
442 FDHB500UK/icountPD
Communication Options

The icountPD may be configured using the icountPD Setup Utility. For more direct control of the device using its
communications protocol, you may also use the Microsoft Windows® HyperTerminal program, but note that this
program is not currently supplied with the Windows Vista™ operating system. These two ways of communicating
with icountPD are described in the following section.

icountPD Setup Utility software (supplied)

Communication Protocol

The Communication protocol for the serial Example:


communication link is to be used with Microsoft [SDF dd/mm/yy] - sets the date format.
Windows HyperTerminal. The settings are as follows:
[RDF] - reads the product date format.
Baud rate 9600
All commands are sent in ASCII characters, and
Data bits 8
the protocol accepts both upper and lower case
Parity None
characters as the examples below:
Stop bits 1
Flowcontrol None SDF
The commands used with this product are made up SdF
of Read, Set and Start / Stop commands.
• Set commands allow the value or values of Note: A full list of commands are detailed in the user
parameters to be set manual
• Read commands allow the value or values or
parameters to be read
• Start/Stop allows the user to start and stop tests.

Parker Hannifin
Hydraulic Filter Division Europe
443 FDHB500UK/icountPD
icountPD
Online Particle Detector

Ordering Information

Standard Products Table


Part number Fluid type Calibration Display Limit relay Communication Moisture Cable connector kit
IPD12222130 Mineral MTD LED YES RS232 / 4 - 20mA NO M12, 8 pin plug connector
IPD12222230 Mineral MTD LED YES RS232 / 4 - 20mA YES M12, 8 pin plug connector
IPD12223130 Mineral MTD LED YES RS232 / 0 - 5V NO M12, 8 pin plug connector
IPD12223230 Mineral MTD LED YES RS232 / 0 - 5V YES M12, 8 pin plug connector
IPD12322130 Mineral MTD Digital YES RS232 / 4 - 20mA NO M12, 8 pin plug connector
IPD12322230 Mineral MTD Digital YES RS232 / 4 - 20mA YES M12, 8 pin plug connector
IPD12323130 Mineral MTD Digital YES RS232 / 0 - 5V NO M12, 8 pin plug connector
IPD12323230 Mineral MTD Digital YES RS232 / 0 - 5V YES M12, 8 pin plug connector

Product Configurator
Key Fluid type Calibration Display Limit relay Communication Moisture Cable connector kit
IPD 1 Mineral 2 MTD 2 LED 2 Yes 2 RS232 / 4-20mA 1 No 10 Deutsch 12-pin DT Series connector
2 Phosphate ester 3 Digital 3 RS232 / 0-5V 2 Yes 30 M12, 8 pin plug connector
3 Aviation fuel RS232/CAN-bus
5
(4 channel) (J1939)

Note - Aviation Fuel option can also be used for Diesel fluids
Note - RS485 option - communication up to 5000 Meters - Contact Parker
Note - Wireless communication (GPRS - LAN - WiFi - Sat) - Contact Parker

Accessories
Part number
Description
Mineral fluids Aggressive fluids
ACC6NE003 ACC6NN002 1 metre hose length
ACC6NN003 ACC6NN004 2 metre hose length
ACC6NN005 ACC6NN006 5 metre hose length
1/4” BSP fitting
ACC6NN007 ACC6NN008
1/8” BSP fitting
ACC6NN009 ACC6NN010
1/8” BNPT fitting
ACC6NN011 ACC6NN012
SPS2021 SPS2061 Single point sampler
S840074 Contact Parker Flow control device
ACC6NN019 Contact Parker Flow control valve
ACC6NN013 12 volt regulated power supply
ACC6NN014 Contact Parker 2 x 5 metre M12 - 8 pin cable kit*
ACC6NN016 Deutsch Connector Kit
ACC6NN017 RS232 To USB cable kit
ACC6NN018 M12 - 8 pin to RS232 engineers tool

* M12 Cable kit consists of two 5 metre cables to enable all output options
(Communications cable and Relay/Power Supply cable)
* * Note that the aggressive fluid hoses are provided as a single hose, not in pairs.
Note: For details on the icountPD Z2 ATEX approved particle detector see page 457.

Reverse Flow
Part number Supersedes Size Flow range l/min Fluid type Port threads capability
STI0144100 STI.0144.100 0 6-25 Mineral 3/8 Yes
STI1144100 STI.1144.100 1 20-100 Mineral 3/4 Yes
STI2144100 STI.2144.100 2 80-380 Mineral 11/4 Yes
STI0148100 STI.0148.100 0 6-25 Aggressive 3/8 Yes
STI1148100 STI.1148.100 1 20-100 Aggressive 3/4 Yes
STI2148100 STI.2148.100 2 80-380 Aggressive 11/4 Yes
STS5117210 STS.5117.210 1 20-100 Mineral 3/4 No
STS5217210 STS.5217.210 2 80-380 Mineral 11/4 No

Parker Hannifin
Hydraulic Filter Division Europe
444 FDHB500UK/icountPD