General Purpose Relays
MKS
Exceptionally Reliable General Purpose
Relay now available with Lockable Test
Button
• IEC Rating of 7A 250 V AC 50/60 Hz,
General use 100,000 cycles.
• Mechanical indicator standard for all models.
• Optional features include lockable test button, LED
indicator, diode surge suppression, varistor, reverse
polarity, and alternate wiring styles.
• UL (RU/CRU), CE and TUV approved.
• RoHS Compliant.
Features
Two-way Action Test Button
Relay in For Momentary For Lock
Normal Operation Operation Operation
Yellow
button
Pull down the test Pull down the test
button to the first button to the second
position, then press the position.
yellow button with an (The contact is now in
insulated tool to the locked position.)
operate the contact.
Model Number Structure
■ Model Number Legend 5. Coil Polarity
MKS@@@@@-@-@ Blank: Standard
1 2 3 4 5 6 7 1: Reverse polarity (DC coil only)
1. Contact Form 6. Surge Absorption
2: DPDT Blank:Standard
3: 3PDT D: Surge absorber diode (DC coil only)
2. Terminals V: Surge absorber varistor (AC coil only)
P: Plug-in 7. Internal Connections DPDT
3. Mechanical Indicator/Test Button Blank: Standard
Blank:Mechanical indicator 2: Non Standard
I: Mechanical indicator and lockable test button Internal Connections 3PDT
4. LED Indicator 5: Standard
Blank: Standard Blank: Non Standard
N: LED indicator 2: Non Standard
8. Rated Voltage
(Refer to “Coil Ratings”.)
General Purpose Relays MKS 277
Ordering Information
■ List of Models
Type Terminals Contact form Internal connections With mechanical indicator With mechanical indicator Coil ratings
(See note 3.) and lockable test button
Basic Plug-in DPDT Standard MKS2P MKS2PI AC/DC
Models Non Standard MKS2P-2 MKS2PI-2
3PDT Standard MKS3P-5 MKS3PI-5
Non Standard MKS3P-2 MKS3PI-2
MKS3P MKS3PI
Models with DPDT Standard MKS2PN(1) MKS2PIN(1) AC/DC
LED Indicator Non Standard MKS2PN(1)-2 MKS2PIN(1)-2
(See note 2.)
3PDT Standard MKS3PN(1)-5 MKS3PIN(1)-5
Non Standard MKS3PN(1)-2 MKS3PIN(1)-2
MKS3PN(1) MKS3PIN(1)
Models with DPDT Standard MKS2P(1)-D MKS2PI(1)-D DC
Diode Non Standard MKS2P(1)-D-2 MKS2PI(1)-D-2
(See note 2.)
3PDT Standard MKS3P(1)-D-5 MKS3PI(1)-D-5
Non Standard MKS3P(1)-D-2 MKS3PI(1)-D-2
MKS3P(1)-D MKS3PI(1)-D
Models with DPDT Standard MKS2PN-D MKS2PIN-D DC
LED Indicator Non Standard MKS2PN-D-2 MKS2PIN-D-2
and Diode
3PDT Standard MKS3PN-D-5 MKS3PIN-D-5
Non Standard MKS3PN-D-2 MKS3PIN-D-2
MKS3PN-D MKS3PIN-D
Models with DPDT Standard MKS2P-V MKS2PI-V AC
Varistor Non Standard MKS2P-V-2 MKS2PI-V-2
3PDT Standard MKS3P-V-5 MKS3PI-V-5
Non Standard MKS3P-V-2 MKS3PI-V-2
MKS3P-V MKS3PI-V
Models with DPDT Standard MKS2PN-V MKS2PIN-V AC
LED Indicator Non Standard MKS2PN-V-2 MKS2PIN-V-2
and Varistor
3PDT Standard MKS3PN-V-5 MKS3PIN-V-5
Non Standard MKS3PN-V-2 MKS3PIN-V-2
MKS3PN-V MKS3PIN-V
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.
Example: MKS2P DC48
Rated voltage
2. The DC coil comes in two types: standard coil polarity and reverse coil polarity.
Refer to Terminal Arrangement and Internal Connections.
Example: MKS3PN1-5 DC24
Reverse coil polarity
3. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams.
■ 10A Sockets (Order Separately)
Item Type Model
Track-mounted 8-pin PF083A-E
Socket 11-pin PF113A-E
8-pin PF083A-D
11-pin PF113A-D
Hold-down Clip PFC-A1
(For PF083A-E and PF113A-E)
278 General Purpose Relays MKS
Specifications
■ Ratings
Coil Ratings
Rated voltage Rated current Coil resistance Must operate Must release Max. voltage Power
voltage voltage consumption
50 Hz 60 Hz
AC 6V 443 mA 385 mA 3.1 Ω 80% max. of rated 30% min. of rated 110% of rated volt- Approx. 2.3 VA
12 V 221 mA 193 mA 13.7 Ω voltage voltage at 60 Hz age at 60 Hz
25% min. of rated Approx. 2.7 VA
24 V 110 mA 96.3 mA 48.4 Ω at 50 Hz
voltage at 50 Hz
110 V 24.2 mA 21.0 mA 932 Ω
120 V 22.2 mA 19.3 mA 1,130 Ω
220 V 12.1 mA 10.5 mA 3,550 Ω
230 V 11.5 mA 10.0 mA 4,250 Ω
240 V 11.0 mA 9.6 mA 4,480 Ω
DC 6V 224 mA 26.7 Ω 15% min. of rated Approx. 1.4 W
12 V 112 mA 107 Ω voltage
24 V 55.8 mA 430 Ω
48 V 28.1 mA 1,710 Ω
100 V 13.5 mA 7,390 Ω
110 V 12.3 mA 8,960 Ω
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.
Contact Ratings
Load Resistive load Inductive load
(cosφ = 1) (p.f. = 0.4)
Contact mechanism Single
Contact material AgSnIn
Rated load NO 10 A, 250 VAC 7 A, 250 VAC
10A, 30 VDC
NC 5 A, 250 VAC
5 A, 30 VDC
Rated carry current 10 A
Max. switching voltage 250 VAC, 250 VDC
Max. switching current 10 A
Max. switching capacity NO 2,500 VA/300 W
NC 1,250 VA/150 W
General Purpose Relays MKS 279
■ Characteristics
Contact resistance 100 mΩ max.
Operate time AC: 20 ms max.
DC: 30 ms max.
Release time 20 ms max.(40 ms max. for built-in diode models)
Max. operating frequency Mechanical: 18,000 operations/hr (no load)
Electrical:1,800 operations/hr (at rated load)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC 50/60 Hz for 1 min. between coil and contacts
1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity and terminals of the same polarity
2,500 VAC 50/60 Hz for 1 min. between current-carrying parts, non-current-carrying parts, and opposite
polarity
Insulation method Basic insulation
Impulse withstand voltage 4.5 kV between coil and contacts (with 1.2 × 50 μs impulse wave)
3.0 kV between contacts of different polarity (with 1.2 × 50 μs impulse wave)
Pollution degree 3
Rated insulation voltage 250 V
Vibration resistance Destruction:10 to 55 Hz, 1.5 mm double amplitude
Malfunction:10 to 55 Hz, 1.0 mm double amplitude
Shock resistance Destruction:1,000 m/s2 (approx. 100 G)
Malfunction:100 m/s2 (approx. 10 G)
Life expectancy Mechanical: 5,000,000 operations min.
Electrical:100,000 operations min.
Min. permissible load 10 mA at 1 VDC P level: λ60=0.1 x 10-6 / ops
Ambient temperature Operating: –40 to 60°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 90 g
Note: 1. The values given above are initial values.
2. Ambient temperature of models with LED indicator is −25 to 60°C.
■ Approved Standards
UL Recognized (File No. E41515) - - Ambient Temp. = 40°C IEC Standard/TUV Certification: IEC61810-1
(Certification No. R50104853)
Coil ratings Contact ratings Operations
6 to 110 VDC N.O. 10 A, 250 V AC 50/60 Hz (Resistive) 100,000 Coil ratings Contact ratings Operations
6 to 240 VAC contact 10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use) 6, 12, 24, 48, N.O. 10 A, 250 V AC 50/60 Hz (Resistive) 100,000
100, 110 VDC contact 10 A, 30 V DC (Resistive)
N.C. 10 A, 250 V AC 50/60 Hz (Resistive) 100,000 6, 12, 24, 100, 7 A, 250 V AC 50/60 Hz (General Use)
contact 10 A, 30 V DC (Resistive) 110, 200, 220,
7 A, 250 V AC 50/60 Hz (General Use) 240 VAC N.C. 5 A, 250 V AC 50/60 Hz (Resistive) 100,000
contact 5 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
Note: 10A UL ratings are with no load on the other contact set.
Note: Maximum carrying current per TUV Certification is 9 A when
CSA Certified by new MK-S relays are mounted in PF083A-E or PF113A-E
Sockets.
Engineering Data
■ Reference Data Rated Carry Current vs. Ambient Rated Temperature
Rated carry current (A)
Maximum Switching Power
Switching current (A)
100 10
50
UL derating curve
30
DC resistive load
with NO contact AC resistive load
with NO contact 5
10
5 AC inductive
load
3 (p.f. = 0.4)
DC resistive AC resistive load
0
load with with NC contact
−40 −20 0 20 40 60 80
NC contact
Ambient temperature (°C)
1
10 30 50 100 300 500 1.000
Switching voltage (V)
Note: The lower limit of the ambient operating temperature for models
with built-in operation indicators is −25°C.
280 General Purpose Relays MKS
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Models without Test Button Models with Lockable Test Button
34.5 max.
34.5 max.
34.5 max. 0.8 52.5 max.
34.5 max. 0.8 52.5 max.
Track Mounted Sockets
See below for Socket dimensions.
Poles Finger-protection models —
Maximum carry current 10 A 5A
2 poles PF083A-E PF083A-D PF083A
3 poles PF113A-E PF113A-D PF113A
Note: If using the PF083A or PF113A Sockets, be sure the maximum carrying current is 5 A or less. When using finger-protection sockets, make
sure the connecting wire terminals are Y-shaped.
PF083A-E (Conforming to EN 50022) PF113A-E (Conforming to EN 50022)
Eight, M3.5 × 7 sems Terminal Arrangement Terminal Arrangement
7 4 Eleven, M3.5 × 7 sems
7 4
52 max. 35.4
52 max. 35.4
33 3.5 2
41 max.
21 max. Mounting Holes 4 34 3.5 2 Mounting Holes
Two, M4 or two 4.5-dia. holes 42.8 max. Two, M4 or two 4.5-dia. holes
31 max.
33±0.2 33±0.2
General Purpose Relays MKS 281
PF083A-D PF113A-D
8 Terminal Arrangement
8
24 22 12 14
Terminal Arrangement
5.5 6 5 4 3
32 24 21 22 12
5.5
8 7 6 5 4
4 27
27
4
Eight, M4 screws
7 8 1 2 Eight, M4 screws
A2 21 11 A1 9 10 2 3
34 A2 11 1 A1 14
31 11
65 Mounting Holes
65
Two, M4 or two 4.5-dia. hole Mounting Holes
Two, M4 or two 4.5-dia. hole
30
30
38
38
Hold-down Clips
PFC-A1
(2 pieces per set)
4.6
60.8
62
6 4.5
Mounting Tracks
PFP-100N, PFP-50N PFP-100N2
(Conforming to EN 50022) (Conforming to EN 50022)
16
7.3±0.15
4.5
4.5
35±0.3 27±0.15 35±0.3 27 24 29.2
15 25 25 25 25 * 15 25 25 25 25 15 1 1.5
15 (5) 1 10 10
10 10 1000±4
1000 (500)*
* The figure in parenthesis is for PFP-50N.
Mounting Height with Sockets
Three
poles
77.8 Two 87.8
(See poles (See 84.3
note.) 74.3 note.)
PF083A(-E) PF113A(-E)
Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.
282 General Purpose Relays MKS
Terminal Arrangement/Internal Connection (Bottom View)
Basic Models MKS2P(I) MKS2P(I)-2 MKS3P(I) MKS3P(I)-2 MKS3P(I)-5
(AC/DC Coil) 4 5 4 5
5 6 7
3 6 3 6 5 6 6
7 5 7 4 8
4 8 4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8 2 10
2 10 2 10 1 11
1 11 1 11
LED Indicator Type MKS2P(I)N MKS2P(I)N-2 MKS3P(I)N MKS3P(I)N-2 MKS3P(I)N-5
(AC Coil) 4 5 4 5
5 6 7
3 6 3 6 5 6 7 6
5 7 4 8
4 8 4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8 2 10
2 10 2 10 1 11
1 11 1 11
LED Indicator Type MKS2P(I)N MKS2P(I)N-2 MKS3P(I)N MKS3P(I)N-2 MKS3P(I)N-5
(DC Coil: 4 5 4 5
Standard Polarity) 6
3 6 3 6 5 6 6 5 7
7 5 7
4 8 4 8
4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8
2 10 2 10
2 10 1 11
1 11 1 11
LED Indicator Type MKS2P(I)N1 MKS2P(I)N1-2 MKS3P(I)N1 MKS3P(I)N1-2 MKS3P(I)N1-5
(DC Coil: 4 5 4 5
Reverse Polarity) 6
3 6 3 6 5 6 6 5 7
7 5 7
4 8 4 8
4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8
2 10 2 10
2 10 1 11
1 11 1 11
Diode Type MKS2P(I)-D MKS2P(I)-D-2 MKS3P(I)-D MKS3P(I)-D-2 MKS3P(I)-D-5
(DC Coil: 4 5 4 5
Standard Polarity) 6
3 6 3 6 5 6 7 6 5 7
5 7 4 8
4 8 4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8
2 10 2 10
2 10 1 11
1 11 1 11
Diode Type MKS2P(I)1-D MKS2P(I)1-D-2 MKS3P(I)1-D MKS3P(I)1-D-2 MKS3P(I)1-D-5
(DC Coil: 4 5 4 5
Reverse Polarity) 6
3 6 3 6 5 6 6 5 7
7 5 7
4 8 4 8
4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8
2 10 2 10
2 10 1 11
1 11 1 11
General Purpose Relays MKS 283
LED Indicator and MKS2P(I)N-D MKS2P(I)N-D-2 MKS3P(I)N-D MKS3P(I)N-D-2 MKS3P(I)N-D-5
Diode Type
4 5 4 5
(DC Coil) 6
3 6 3 6 6 6 5 7
5 7 5 7 4 8
4 8 4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8 2 10
2 10 2 10 1 11
1 11 1 11
Varistor Type MKS2P(I)-V MKS2P(I)-V-2 MKS3P(I)-V MKS3P(I)-V-2 MKS3P(I)-V-5
(AC Coil) 5 5
4 4
3 6 3 6 5 6 7 5 6 7
5 6 7
4 8 4 4 8
8
2 7 2 7
3 9 3 9
3 9
1 8 1 8
2 10 2 10
2 10
1 11 1 11 1 11
LED Indicator and MKS2P(I)N-V MKS2P(I)N-V-2 MKS3P(I)N-V MKS3P(I)N-V-2 MKS3P(I)N-V-5
Varistor Type 5 5
4 4
(AC Coil) 6
3 6 3 6 6 6 5 7
5 7 5 7 4 8
4 8 4 8
2 7 2 7 3 9
3 9 3 9
1 8 1 8 2 10
2 10 2 10 1 11
1 11 1 11
Safety Precautions
■ Safety Precautions for Correct Use
Installation
Recommend mounting MK-S Relay so that side with wiring diagram is facing down.
Handling
Check coil polarity when wiring LED Indicator and Diode Models.
Test Button
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON.
Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay circuits.
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the
Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only
the requirements for basic insulation are fulfilled.
284 General Purpose Relays MKS
Omron Electronic Components, LLC (b) Use in consumer Products or any use in significant quantities.
(c) Energy control systems, combustion systems, railroad systems, aviation systems,
Terms and Conditions of Sales medical equipment, amusement machines, vehicles, safety equipment, and
installations subject to separate industry or government regulations.
I. GENERAL (d) Systems, machines, and equipment that could present a risk to life or property.
1. Definitions: The words used herein are defined as follows. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
(a) Terms: These terms and conditions SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
(b) Seller: Omron Electronic Components LLC and its subsidiaries AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
(c) Buyer: The buyer of Products, including any end user in section III through VI PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
(d) Products: Products and/or services of Seller WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
(e) Including: Including without limitation 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY
invoices, purchase orders and other documents, whether electronic or in writing, relating SELLER.
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of
purchase order or other documents which are inconsistent with, or in addition to, these a programmable Product.
Terms.
3. Distributor: Any distributor shall inform its customer of the contents after and including IV. WARRANTY AND LIMITATION
section III of these Terms. 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in
materials and workmanship for a period of twelve months from the date of sale by Seller
II. SALES (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,
Buyer agrees to pay the price in effect at the time the purchase order is accepted by NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
Seller. Payments for Products received are due net 30 days unless otherwise stated in PURPOSE OF THE PRODUCTS.
the invoice. Buyer shall have no right to set off any amounts against the amount owing in 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form
respect of this invoice. originally shipped with Buyer responsible for labor charges for removal or replacement
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an
Buyer after deducting transportation charges, taxes and duties, and will be allowed only amount equal to the purchase price of the Product; provided that there shall be no
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past liability for Seller or its affiliates unless Seller's analysis confirms that the Products were
due amounts owing to Seller. correctly handled, stored, installed and maintained and not subject to contamination,
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum abuse, misuse or inappropriate modification. Return of any Products by Buyer must be
legal rate, whichever is less, on any balance not paid within the stated terms. approved in writing by Seller before shipment.
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF
shall make remittance to Seller at the then current exchange rate most favorable to PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED
Seller; provided that if remittance is not made when due, Buyer will convert the amount WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
to U.S. dollars at the then current exchange rate most favorable to Seller available WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL
during the period between the due date and the date remittance is actually made. LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining THE PRODUCT ON WHICH LIABILITY IS ASSERTED.
any government approvals regarding the importation or sale of the Products. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its
7. Taxes: All taxes, duties and other governmental charges (other than general real employees from and against all liabilities, losses, claims, costs and expenses (including
property and income taxes), including any interest or penalties thereon, imposed directly attorney's fees and expenses) related to any claim, investigation, litigation or proceeding
or indirectly on Seller or required to be collected directly or indirectly by Seller for the (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or
manufacture, production, sale, delivery, importation, consumption or use of the Products omissions under these Terms or in any way with respect to the Products.
sold hereunder (including customs duties and sales, excise, use, turnover and license
taxes) shall be charged to and remitted by Buyer to Seller. V. INFORMATION; ETC.
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive
Seller reserves the right to stop shipments or require satisfactory security or payment in property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way
advance. If Buyer fails to make payment or otherwise comply with these Terms or any without the written permission of Seller. Buyer (at its own expense) shall indemnify and
related agreement, Seller may (without liability and in addition to other remedies) cancel hold harmless Seller and defend or settle any action brought against Seller to the extent
any unshipped portion of Products sold hereunder and stop any Products in transit until that it is based on a claim that any Product made to Buyer specifications infringed
Buyer pays all amounts, including amounts payable hereunder, whether or not then due, intellectual property rights of another party.
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or
accounts. tooling, all engineering and tooling shall remain the exclusive property of Seller. All
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer information and materials supplied by Seller to Buyer relating to the Products are
indemnifies Seller fully against all costs or expenses arising in connection therewith. confidential and proprietary, and Buyer shall limit distribution thereof to its trusted
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from employees and strictly prevent disclosure to any third party.
causes beyond its control, including earthquakes, fires, floods, strikes or other labor 3. Performance Data: Performance data is provided as a guide in determining suitability
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, and does not constitute a warranty. It may represent the result of Seller's test conditions,
delay in or lack of transportation or the requirements of any government authority. and the users must correlate it to actual application requirements.
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: 4. Change In Specifications: Product specifications and descriptions may be changed at
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise any time based on improvements or other reasons. It is Seller’s practice to change part
stated in writing by Seller), at which point title to and all risk of loss of the Products numbers when published ratings or features are changed, or when significant
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in engineering changes are made. However, some specifications of the Product may be
the Products until the full purchase price is paid by Buyer; changed without any notice.
(b) Delivery and shipping dates are estimates only; and 5. Errors And Omissions: The information on Seller’s website or in other documentation
(c) Seller will package Products as it deems proper for protection against normal has been carefully checked and is believed to be accurate; however, no responsibility is
handling and extra charges apply to special conditions. assumed for clerical, typographical or proofreading errors or omissions.
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses
occurring before delivery to the carrier or any claim related to pricing or other charges regarding (a) export of the Products or information provided by Seller; (b) sale of
must be presented in detail in writing to Seller within 30 days of receipt of shipment. Products to forbidden or other proscribed persons or organizations; (c) disclosure to non-
citizens of regulated technology or information.
III. PRECAUTIONS
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY VI. MISCELLANEOUS
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING between Buyer and Seller shall operate as a waiver of rights by Seller.
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. dispute hereunder.
Buyer acknowledges that it alone has determined that the Products will meet their 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller
requirements of the intended use in all cases. Buyer must know and observe all relating to the Products, and no provision may be changed or waived unless in writing
prohibitions of use applicable to the Product/s. signed by the parties.
2. Use with Attention: The followings are some examples of applications for which 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall
particular attention must be given. This is not intended to be an exhaustive list of all not invalidate any other provision.
possible use of any Product, nor to imply that any use listed may be suitable for any
Product:
(a) Outdoor use, use involving potential chemical contamination or electrical
interference.
General Purpose Relays MKS
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's pro-
dards, codes or regulations which apply to the combination of the Product in gramming of a programmable product, or any consequence thereof.
Buyer's application or use of the Product. At Buyer's request, Seller will pro- 3. Performance Data. Performance data given in this publication is provided as
vide applicable third party certification documents identifying ratings and limi- a guide for the user in determining suitability and does not constitute a war-
tations of use which apply to the Product. This information by itself is not ranty. It may represent the result of Seller's test conditions, and the users must
sufficient for a complete determination of the suitability of the Product in com- correlate it to actual application requirements. Actual performance is subject to
bination with the end product, machine, system, or other application or use. Seller's Warranty and Limitations of Liability.
Buyer shall be solely responsible for determining appropriateness of the par- 4. Change in Specifications. Product specifications and accessories may be
ticular Product with respect to Buyer's application, product or system. Buyer changed at any time based on improvements and other reasons. It is our prac-
shall take application responsibility in all cases but the following is a non- tice to change part numbers when published ratings or features are changed,
exhaustive list of applications for which particular attention must be given: or when significant construction changes are made. However, some specifica-
(i) Outdoor use, uses involving potential chemical contamination or electrical tions of the Product may be changed without any notice. When in doubt, spe-
interference, or conditions or uses not described in this document. cial part numbers may be assigned to fix or establish key specifications for
(ii) Energy control systems, combustion systems, railroad systems, aviation your application. Please consult with your Seller representative at any time to
systems, medical equipment, amusement machines, vehicles, safety confirm actual specifications of purchased Product.
equipment, and installations subject to separate industry or government 5. Errors and Omissions. The information in this publication has been carefully
regulations. checked and is believed to be accurate; however, no responsibility is assumed
(iii) Use in consumer products or any use in significant quantities. for clerical, typographical or proofreading errors, or omissions.
(iv) Systems, machines and equipment that could present a risk to life or 6. RoHS Compliance. Where indicated, our products currently comply, to the
property. Please know and observe all prohibitions of use applicable to this best of our knowledge as of the date of this publication, with the requirements
product. of the European Union's Directive on the Restriction of certain Hazardous
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS Substances ("RoHS"), although the requirements of RoHS do not take effect
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM until July 2006. These requirements may be subject to change. Please consult
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT our website for current information.
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at [Link] – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONIC OMRON ON-LINE
COMPONENTS LLC Global - [Link]
55 E. Commerce Drive, Suite B USA - [Link]
Schaumburg, IL 60173
847-882-2288
Cat. No. X301-E-1 06/09 Specifications subject to change without notice Printed in USA
General Purpose Relays MKS