ReleaseNote PipeWIZARD 4x

This document provides release notes for PipeWIZARD software versions 4.5R1 through 4.3R2. The updates include: 1) New features like automatic height sizing, keyboard shortcuts, cumulative length readings, and API 1104 default indications. 2) Bug fixes to issues with calibration boxes, auto-calibration, defect tables, group parameters, and software stability. 3) Each release improves compatibility with newer versions of Windows and fixes bugs related to calibration, inspection data, reports, and software performance.

Uploaded by

Dennis Chai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
246 views5 pages

ReleaseNote PipeWIZARD 4x

This document provides release notes for PipeWIZARD software versions 4.5R1 through 4.3R2. The updates include: 1) New features like automatic height sizing, keyboard shortcuts, cumulative length readings, and API 1104 default indications. 2) Bug fixes to issues with calibration boxes, auto-calibration, defect tables, group parameters, and software stability. 3) Each release improves compatibility with newer versions of Windows and fixes bugs related to calibration, inspection data, reports, and software performance.

Uploaded by

Dennis Chai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PipeWIZARD Release Notes

PipeWIZARD 4.5R1 2019-12-05

Compatible with Windows 7 -SP1 (64-bit), Windows 8.1 (64-bit) and Windows 10 (64-bit)

- New: Overtrace values are now automatically available in Calibration Table (G)
- New: Automatic height sizing using overtrace values from last calibration and merge function
- New: Reduced time to display Calibration Table (G)
- New: dB correction column in Calibration Table (G) is now editable
- New: Calibration Table (G) is now also available from INSP files (weld scan).
- New: Max amplitude per group is now available in defect table and reports
- New: ID and OD ligaments are now displayed in defect table and reports
- New: keyboard shortcut (Ctrl+U) is now active to open/close UT-Settings window
- New: Cumulative length reading is now available for multiple selection of groups (merged value)
- New: New default indications list now based on API 1104 (legend available)
- 34082 Cal boxes – Fixed intermittent issue showing cal boxes after loading “Original Data”
- 35593 Cal boxes – Fixed intermittent issue showing cal boxes on Inspection data
- 35594 Cal boxes – Fixed intermittent issue not showing cal boxes on Calibration data
- 35612 Auto-Cal – Fixed issue in auto-calibration feature when changing digitizing frequency
- 35611 Auto-Cal thresholds in Preferences are now saved in Setup file
- 31156 The default repertory to save a report after PrintToPDF or ExportToExcel is now the last one used
- 33130 DLA probes are now properly named in SetupCreator/Probes.
- 33762 Wedge and probe lists are now fully updated
- 31159 Defect Table – Fixed issue on indication name (“type”) resetting when editing indication with custom name

PipeWIZARD 4.4R3 2017-08-04

Compatible with Windows 7 -SP1 (64-bit), Windows 8.1 (64-bit) and Windows 10 (64-bit)

- 34751 Amplitude reading of UT groups – Fixed issue in cal box table when scan resolution is less than 1mm

PipeWIZARD 4.4R2 2016-11-29

Compatible with Windows 7 -SP1 (64-bit), Windows 8.1 (64-bit) and Windows 10 (64-bit)

- New: Possibility to add a flat area to HP zone on bevel configuration


- New: Possibility to add a horizontal dash line on bevel drawing representing a clad interface
- New: Coupling readings available in main interface
- New: WT (wall thickness) group type now available in SetupCreator
- New: Software can now be used with Windows 8 and Windows 10 in addition to Windows 7
- 33598 Offline version of SetupCreator is now available. Import/export of .sce file is fixed
- 33408 Global Report – Fixed issue with data file date
- 33663 Cal boxes – Fixed issue with cal boxes when a group is added in SetupCreator
- 33707 Cal boxes – Fixed issue with cal boxes when a group is modified in SetupCreator
- 33766 Help menu is now functional
- 33496 Report Configuration – Fixed issue when loading setup file with different report configuration
- 33874 Cal boxes – Fixed issue with calibration table size
- 33876 Cal boxes – Fixed issue with cal boxes when a strip is added to layout created automatically

1|Page
- 33938 Sectorial group – Fixed calculation issue when range is changed on sectorial group
- 33974 Cal boxes – Fixed issue with cal boxes when using layout #2 and #3
- 33986 Stability – Fixed issues to increase significantly the overall stability of the software
- 34053 Linear group – Fixed issue with wedge delay calculation when elt start or elt stop of a linear group is modified
- 34094 Calibration Report – Fixed issue with layout #2 and #3 in calibration report
- 31167 Scan sequence parameters – Fixed issue when loading a data file having different scan sequence parameters
- 34106 DLA wedges – Fixed issue with custom wedges for DLA probes that didn’t appear in the wedge list

PipeWIZARD 4.4R1 2016-08-18

Compatible only with Windows 7 (64bits) and Windows 8 (analysis and viewer modes only).

- New: Calibration auto-verdict (cal box) and calibration table report are now available
- New: Customizable sizing table is now available (in Expert mode)
- 33476 Encoder resolution – Fixed issue with encoder resolution parameter when loading a setup file
- 33333 Asymmetric gates – Fixed display issue with “live” stripchart during inspection for groups with asymmetric gates

Note: The offline version of SetupCreator is not available in 4.4R1 version for maintenance reasons. It will be available in a future
version.

PipeWIZARD 4.3R6 2016-04-18

Compatible only with Windows 7 (64bits) and Windows 8 (analysis and viewer modes only).

- 31720 Adv. Calculator – Fixed issue that freezes A-scan signal when changing some parameters in Adv. Cal.
- 32729 Scanning Sensitivity – Fixed issue with scanning sensitivity readings in analysis mode
- 30551 Scanning Sensitivity settings are now saved in Setup file
- 32570 Voltage – Fixed issue giving inconsistency between groups
- 31991 Fixed issue with automatic layout generation when groups are added manually in SetupCreator
- 32689 Fixed issue with automatic layout generation after import from offline version of SetupCreator (missing strips)
- 32691 Fixed issue with automatic layout generation after import from offline version of SetupCreator (all strips were
identical)
- 29328 Layouts – Fixed issue in the Group list in pane properties (duplicate names)
- 31926 Bevel Definition – Fixed issue leading to random crash when changing bevel type (J to CRC, or CRC to J).
- 32635 Optimize software performance – delay when changing mode (inspection to analysis, analysis to setup, etc)
- 29384 Optimize software performance – Reduce display flicks when changing mode (calibration, inspection, setup)
- 32918 Suggested saving folder for pdf data reports is now the same as data folder
- 33098 [Range] Fixed issue with Full Range option that stayed active after a calibration.
- 33106 Transverse and Coupling groups are not reprogrammed anymore after the next "Apply" in SetupCreator if Start
and/or Range parameters have been modified.

Note: The offline version of SetupCreator is not available in 4.3R6 version for maintenance reasons. It will be available again in a future
version.

PipeWIZARD 4.3R5 2016-02-03

Compatible only with Windows 7 (64bits) and Windows 8 (analysis and viewer modes only).

- New: A27-DLA probe and associated wedges are now available directly from SetupCreator/Probes drop-down menus.
- New: [Reports] 2 new editable fields added (total of 9) to the report header in report configuration window.
- 31510 [SetupCreator] Fixed issue occurring when changing type of a group automatically generated.
- 31369 [SetupCreator] Fixed issue with gates position and AdjustFocus button occurring when changing Tx/Rx for a group.
- 31628 [SetupCreator] Fixed issue with added group when using “beam” button.

2|Page
- 32747 [Reporting] Fixed issue with data file integrity when moved to another location.
- 32847 [Reporting] Fixed issue (blank strip appearing in strip-chart view) with data pdf reports.
- 32848 [Reporting] Fixed issue with report configuration being lost after inspection run.
- 32849 [Reporting] Fixed issue with data report preview (error message).
- 32865 [Auto Backup] Fixed issue with auto backup activation when loading a data file.

PipeWIZARD 4.3R4 2015-11-16

- 32829 [Reporting] Fixed a runtime error occurring when opening data report while one of the analysis layouts has empty
view (no data).

PipeWIZARD 4.3R3 2015-11-02

- 32708 [Stability] Software doesn’t crash anymore after 20 scans

PipeWIZARD 4.3R2 2015-03-17

- New: New reporting tools (Setup Report, Data Report, Global Report)
- 28462 [Stability] Going back quickly to setup after inspection does not cause crash anymore
- 29116 [Data file][Crash] In Analysis Mode, loading a .rdt file does not cause PWZ to crash anymore
- 29800 [File] Increase protection on "pws" and "pwzd" files
- 29918 [Layout] In ViewProperties for VolumetricMerge, "Link to Reference Cursor" in "DataSource" tab is now saved
- 30038 [SetupCreator][Probe] Deleting unused probe resets all beams + Reset button do not cause errors anymore
- 30039 [AutomaticLayout] New Automatic Layout for Analysis 2
- 30040 [DefectReading] Set "Cumulative Threshold" to 20% by default instead of 3%
- 30169 Menu help does not work
- 30172 [Layout] Old Data files and Setup files have now "Show Defect" checked in view properties – It is now possible to
uncheck “Show defect”.
- 30389 [Stability] Performing a second inspection quickly after another does not cause PWZ to crash anymore
- 30434 [SetupCreator] Issue of importing data from a Linear group in SetupCreator is now fixed
- 30467 [Analysis] Issue with saving modifications made in a Data file in Analysis mode is now fixed
- 30468 [Analysis] Issue with defect table when trying to re-open a closed Data file in the same PWZ session is now fixed
- 30472 [Application] Issue with Angle Resolution value reset to 1.0 after reloading a previously saved setup is now fixed
- 30488 [SetupCreator] Re-adding probe just deleted is now working properly.
- 30492 [UT Settings] After duplicating a group, UT Settings is no more resetting the groups below in the list.
- 30499 [File] Attribute files are now saved
- 30900 [SetupCreator] The Gates Auto-setup function does now work properly
- 30950 Data file (*.pwzd) opened in setup mode can now be closed without any issue.
- 31020 [Reports] It is now possible to produce a report from a PWZ4.0 data file.
- 31022 [Display] No more display flicking after a Preview or a Print command
- 31049 [Installation] Improved overall stability of PWZ software after numerous acquisition scans.
- 31100 [SetupCreator] Issue with incorrect Elt Adj. of Rx beams in Variable Wall Thickness mode is now fixed
- 31127 [Display] Boxes related to added defects in a previous acquisition do not appear anymore in next acquisition
- 31152 Remove wrong warning message after closing application in analysis mode
- 31153 Issue with Load original data from setup mode is now fixed
- 31164 [Advanced Calculator] Issue with opening Advanced Calculator in post-inspection is now fixed
- 31166 [Parameters] Default gain changed to 35 dB instead of 25 dB
- 31175 [SetupCreator] Setup imported from standalone SetupCreator now works properly
- 31176 Issue with Load last calibration and load last inspection when returning to setup is now fixed

3|Page
- 31198 Remove software version and thickness value from 2D-view image in Viewer mode.

PipeWIZARD 4.2R5 2014-08-08

- 29773 [SetupCreator] Pitch & Catch Group. Change on Rx velocity is now correctly managed by SetupCreator.
- 29775 [Probe Definition] Wedges list has been updated.
- 29790 [SetupCreator] No more probe_override appearing.
- 29791 [PWZ] Rescan button works correctly now.
- 29814 [Probe Definition] Change on Skew is now possible after a modification on Index offset via UT Settings.

PipeWIZARD 4.2R4 2014-07-22

- 28307 [Probe Definition] Any change on parameters, in Probe definition, only now regenerate the Beams and Gates and
not the Targets.
- 29731 PWZ4.2R4 is now able to open under Window XP.

PipeWIZARD 4.2R3 2014-06-19

- 28268 [Bevel Definition] Height of 0mm is now accepted for bevel sections HP, LCP and ROOT.
- 28269 [View Properties] Multiple Strip Charts deletion is now functional.
- 28273 [Analysis Layouts] TOFD calibration stays active when toggling between Layouts.
- 28276 [Pop up Message] ¨Do not show again¨ option is now available in ¨Save to Archive¨ pop up window.
- 28292 [Viewer] TOFD calibration is now available in Viewer mode.
- 28293 [Supervisor mode] Activation Password is now linked to the computer instead of software session.
- 28397 [Viewer] Improper pop up message when closing a Viewer session has been removed.
- 28463 [Weld Overlay] Weld Overlay is no more by default in TOFD Side B view.
- 28508 [Saved File] Volumetric Merge and TOFD calibration are now saved automatically with the Data file.
- 28510 [Readings] Gate B-A Reading is now functional.
- 28569 [Report] Printing a report from an ¨Original Data¨ file is now functional.
- 28600 [Group Calibration] Beam Skew is no more affected after a single Group calibration.
- 28601 [Calibration] Velocity and Delay calibration is now functional.
- 28616 [SC] 0° Linear Group is now properly generated.
- 28620 [Readings] ¨Acq Date¨reading is now available in a Strip Charts View.
- 28644 [SC] VWT Group tags (HIGH, MED, LOW) are now correctly imported.
- 28645 [Automatic Layouts] Correction of default Color Palette.
- 28685 [Layouts] Color for signal above 100% is now functional in Color Palette.
- 28291 [Windows 8] PWZ software is now also running under Windows 9 (analysis and viewer modes only).
- 28294 [Software session] Only one Inspection session could be opened at the time. Multiple Analysis sessions are
allowed (even during inspection).
- 28306 [Probe Definition] Probe(*) functionality has been disabled.
- 28822 [Report] UTC time and Date have been removed from report.
- 28910 [Scanner Control] Motor control interface behavior has been reviewed and is fully functional.
- 29025 [Layouts] Default boxes in Strip Charts in Strip Charts view are now appearing on every single Layout.
- 29098 [Supervisor Mode] Activation password modification is no more requested after a ¨signed out¨ from the
supervisor mode.
- 29103 [Probe Definition] Changing probe name is now fully functional.
- 29116 [Data file] Loading a .rdt file is now working correctly.
- 28183 [Bootp] Updated with the latest Mac adress Ranges (new Bootp version 6.4R3).
- 29383 [Rescan] Rescan button is now fully functional.

4|Page
PipeWIZARD 4.2R2 2014-01

New features and improvements

- Software now runs under Microsoft OS Windows 7 and Windows XP


- New data file format *.pwzd now includes the setup file
- Data from 270° skew probe are now displayed on the left side of the strip-charts view (as per convention).
- VWT (Variable Wall Thickness) option is now available
- Possibility to have Inspection and Analysis sessions opened simultaneously
- SetupCreator allows re-generation of Beams and Gates without affecting Target positions
- Software can now use Access 2013 (or Runtime) and Access 2010 (or Runtime)
- SetupCreator: probes/wedges database (Probe parameters) have been updated
- Software menus have been simplified
- Sectorial and Linear scans feature issues are fixed
- SetupCreator: the “star” feature (when a group is modified outside SetupCreator) has been removed
- Auto-calibration tool (G button) has now the first selected group displayed in the dialog box.
- Defect ID number (in the Defect table) is now linked and sorted accordingly to the circumferential position (x axis) of the
defect. - Defect ID numbers are reset if a defect is deleted from the table.
- Shortcuts F4 (Save Display Preference) and SHIFT+F4 (Apply Display Preference) are now available.
- SetupCreator: negative probe index offset (Probe parameters) is now accepted, allowing the wedge to sit on the weld.
- SetupCreator: changing the beam aperture (number of elements) keeps the beam centered to its initial position.
- Mouse focus on Group selection box now works correctly (no more unintentional modification on Gain as previously)
- Gates are no more reset after modification done on another group in SetupCreator
- No more issue with root angle of 90° (in Bevel Definition).
- “Apply to all zones” option is no more checked by default in Define Colors settings for the Strip-Charts.
- SetupCreator: “Adjust Focus” no more active for conventional groups.
- SetupCreator: no more re-generation when probe Scan Axis Offset is modified.
- SetupCreator: Hzone modification will no more generate a new set up.
- Analysis default Layout is corrected to Analysis 1 rather than Inspection.
- Automatic Volumetric Merge by Group issue has been fixed
- Modifying a group in the Advanced Calculator, does not create several groups in SetupCreator anymore

5|Page