Low Voltage Power Cables Guide

This document provides specifications for low voltage single core unarmored cables. The cables have stranded copper conductors that are insulated and sheathed with PVC. They are used for power distribution in indoor and outdoor locations that are damp or wet, such as in industrial plants. The document lists various cable models with different conductor cross-sectional areas and current ratings for different laying conditions.

Uploaded by

amr ibrahim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
254 views1 page

Low Voltage Power Cables Guide

This document provides specifications for low voltage single core unarmored cables. The cables have stranded copper conductors that are insulated and sheathed with PVC. They are used for power distribution in indoor and outdoor locations that are damp or wet, such as in industrial plants. The document lists various cable models with different conductor cross-sectional areas and current ratings for different laying conditions.

Uploaded by

amr ibrahim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Low Voltage Cables

0.6/1 (1.2) KV Single Core Unarmoured Cables

Single Core Cables, with Stranded


Circular Copper Conductors,
PVC Insulated and PVC Sheathed

Description
•Soft annealed stranded Copper conductor. Insulated with PVC compound rated 70 °C and sheathed
with PVC Compound layer.
•Cables are produced according to IEC 60502.
Application
•For outdoor and indoor installations in damp and wet locations. They are normally used for power
distribution in urban networks, industrial plants, as well as in thermopower and hydropower stations.

1 Core - Cu/PVC/PVC

Maximum Conductor Resistance Current Rating


Nominal Laid in ground Laid in free air (Shaded)
Approx.
Cross Approx.
Product DC at AC at Flat Flat Trefoil Overall
sectional Flat Trefoil Duct
Seperated Touched Touched Weight
Code 20 °C 70 °C Diameter
area

mm2 m m A A A A A A mm Kg/Km
CP1-T101-U08 4 4.61 5.51 53 53 38 50 37 35 7.1 87
CP1-T101-U09 6 3.08 3.68 65 66 47 65 48 46 7.6 113
CP1-T101-U10 10 1.83 2.17 88 89 62 89 9 62 8.3 154
CP1-T101-U11 16 1.15 1.37 113 113 77 108 85 79 9.3 216
CP1-T101-U12 25 0.727 0.8701 143 144 101 143 112 109 10.6 320
CP1-T101-U13 35 0.524 0.6273 171 173 123 176 138 134 11.7 410
CP1-T101-U14 50 0.387 0.4635 203 205 148 214 170 165 13.4 545
CP1-T101-U15 70 0.268 0.3214 248 252 183 271 215 209 15 745
CP1-T101-U16 95 0.193 0.232 296 301 224 332 267 259 17.1 1020
CP1-T101-U17 120 0.153 0.1845 337 342 255 386 310 301 18.5 1260
CP1-T101-U18 150 0.124 0.1501 378 383 292 442 357 347 20.5 1550
CP1-T101-U19 185 0.0991 0.1207 426 433 333 510 415 402 22.8 1925
CP1-T101-U20 240 0.0754 0.0931 494 501 393 608 496 481 25.8 2500
CP1-T101-U30 300 0.0601 0.0755 556 565 450 704 575 558 28.8 3110
CP1-T101-U40 400 0.047 0.0608 629 639 516 819 669 648 32 3975
CP1-T101-U50 500 0.0366 0.0495 709 721 594 957 777 753 36 5080
CP1-T101-U60 630 0.0283 0.041 792 807 672 1113 893 864 39.7 6385
CP1-T101-U70 800 0.0221 0.035 874 891 753 1284 1014 982 44.2 8260
CP1-T101-U80 1000 0.0176 0.0308 956 975 845 1478 1154 1116 51.7 10345
The above data is approximate and subjected to manufacturing tolerance.