40LM 040~100 – PRODUCT DATA DIGEST

The World Leading Air-conditioning Company


TABLE OF CONTENTS

DESCRIPTIONS PAGE
FEATURES & SPECIFICATIONS 2

PHYSICAL DIMENSION - UNIT SIZE 40LM040 3

PHYSICAL DIMENSION - UNIT SIZE 40LM050 4

PHYSICAL DIMENSION - UNIT SIZE 40LM060 5

PHYSICAL DIMENSION - UNIT SIZE 40LM070 6

PHYSICAL DIMENSION - UNIT SIZE 40LM090 7

PHYSICAL DIMENSION - UNIT SIZE 40LM100 8

PERFORMANCE DATA COOLING CAPACITIES 9

PERFORMANCE DATA COIL PRESSURE DROP 10 - 11

FAN PERFORMANCE 12 - 13

SOUND PRESSURE LEVEL DATA 14

ELECTRICAL DATA 15

GUIDE SPECIFICATIONS 16
FEATURES & SPECIFICATIONS

Any Room, Every Room Flexibility In An Air Conditioning System


 Chilled Water Furred-in model with Plenum Fan Coil units
 The low silhouette styling of this unit makes it a popular choice for “in-the-ceiling” or “over the closet”
applications in all types of building
 Horizontal ducted application
 Insulated & painted condensate drain pan and a factory fitted frame complete with filter media
 Installed with direct driven forward curved centrifugal fans and 3 speed motor ensures quiet operation
 Standard copper tube aluminum fins (Cu/Al) evaporator coil for maximum heat transfer
 Carrier Lanced Sine Wave fin pattern ensures energy efficient performance
 Units shall be manufactured as left-hand side (in the direction of air flow) piping connection as standard

GENERAL
Type Chilled Water Fan Coil
Model 040 050 060 070 090 100
Nominal Capacity kW 12.2 14.7 17.6 20.9 26.5 29.9
Btu/hr 41,580 50,251 60,218 71,467 90,367 102
Air Quantity (Range)l/s 430 - 657 421 - 659 563 - 780 784 - 1283 825 - 1232 1271 - 1813
Power Supply V/Ph/Hz 230/1/50
FAN
Type Centrifugal Forward Curved Blades
Drive Direct Drive
Quantity pcs 1 2
Max Rev rpm 1500
Diameter mm 241
MOTOR
Type Permanent Split Capacitor, 3 Speeds
Quantity pcs 1
Power Input kW 0.47 0.47 0.83 1.01 1.01 1.41
Power Output kW 0.32 0.32 0.46 0.75 0.75 0.80
Full Load Amps A 2.46 2.46 4.40 4.55 4.55 7.40
Rev rpm 1350 1350 1200 1360 1360 1405
COIL
Type Copper Tube, Aluminium Plate Fins
Row - Fins/in 2 - 15 3 - 15 4 - 15 3 - 15 4 - 15 3 - 15
Face Area m2 0.343 0.343 0.343 0.437 0.437 0.613
FILTER
Type Washable / Throw Away
Size (H x W x D) mm 398 x 744 x 12 398 x 944 x 12 398 x 1344 x 12
Quantity pcs 1
CONNECTIONS
Supply Inch 1" BSPT MPT
Return Inch 1" BSPT MPT
Drain Pipe Inch 3/4" NPT MPT
Net weight Kg 66.00 67.00 69.00 92.00 97.00 115.00
DIMENSIONS
Height mm 480
Width mm 1000 1200 1600
Length mm 680
FLA: FULL LOAD AMPS

2
PHYSICAL DIMENSION – UNIT SIZE 40LM 040

20.0 960.0

109.1 748.9

53.7

680.7
420.0

130.7
23.2

235.0 382.5
WATER OUT
1000.0 1 INCH BSP GRADE B (MPT)
1012.0 53.8
WATER IN
1 INCH BSP GRADE B (MPT)
102.1

TOP VIEW CONTROL BOX


31.2

54.9

260.0

480.0 109.1 368.0


241.3

183.9
112.8

188.8 16.4
237.9
120.7
FRONT VIEW
3/4 INCH NPT (MPT) DRAIN TUBE

RIGHT SIDE VIEW

3
PHYSICAL DIMENSION – UNIT SIZE 40LM 050

20.0 960.0

109.1 748.9

53.7

680.7 420.0

130.7 23.2

WATER OUT
235.0 382.5
1 INCH BSP GRADE B (MPT)
1000.0 53.8
WATER IN
1012.0 1 INCH BSP GRADE B (MPT) 101.7
CONTROL BOX

TOP VIEW 31.2

54.9

260.0

480.0 241.3 109.1 368.0

183.9
112.8

189.3
16.4
237.9
120.7
3/4 INCH NPT (MPT) DRAIN TUBE
FRONT VIEW

RIGHT SIDE VIEW

4
PHYSICAL DIMENSION – UNIT SIZE 40LM 060

20.0 960.0

109.1 748.3

53.7

680.7 420.0

130.7

348.5 303.0 23.2


WATER OUT
1000.0 1 INCH BSP GRADE B (MPT)

1012.8
WATER IN
1 INCH BSP GRADE B (MPT) 53.8
TOP VIEW 101.7

CONTROL BOX

20.2

54.9

260.0

480.0 109.1 368.0 480.0


241.3

183.9
112.8

16.4
188.8 237.9
120.7
FRONT VIEW

3/4 INCH NPT (MPT) DRAIN TUBE

RIGHT SIDE VIEW

5
PHYSICAL DIMENSION – UNIT SIZE 40LM 070

20.0 1160.0

109.1 948.9

53.0

680.0 420.0

130.0

250.5 235.0 229.0 235.0 23.9

1200.0 WATER OUT


1 INCH BSP GRADE B (MPT)
1212.0
WATER IN
1 INCH BSP GRADE B (MPT) 47.7
TOP VIEW
CONTROL BOX
101.7
33.2

54.9

260.0

480.0 275.8 109.1 368.0

183.5

91.0

188.4 237.3 16.4

120.7
FRONT VIEW
3/4 INCH NPT (MPT) DRAIN TUBE

RIGHT SIDE VIEW

6
PHYSICAL DIMENSION – UNIT SIZE 40LM 090

20.0 1160.0

109.1 948.9

680.0 420.0

130.0

23.8
189.5 303.0 215.0 303.0

1200.0 WATER OUT


1 INCH BSP GRADE B (MPT) 47.7
1212.0
WATER IN 101.7
1 INCH BSP GRADE B (MPT)
TOP VIEW
CONTROL BOX
23.8

54.9

260.0

480.0 109.1 368.0


275.8

183.5
91.0

16.4
188.4 237.9 120.7

FRONT VIEW
RIGHT SIDE VIEW

3/4 INCH NPT (MPT) DRAIN TUBE

7
PHYSICAL DIMENSION – UNIT SIZE 40LM 100

20.0 1560.0

109.1 1348.9

54.0

680.0 420.0

130.4

23.4
389.5 303.0 215.0 303.0

1600.0
WATER OUT
1612.0
1 INCH BSP GRADE B (MPT)

WATER IN
47.7
TOP VIEW 1 INCH BSP GRADE B (MPT)

CONTROL BOX 101.7

23.8
23.8

54.9

260.0

480.0 277.1 109.1 368.0

182.3 16.4
94.4

190.2 237.9

FRONT VIEW 120.7


RIGHT SIDE VIEW

3/4 INCH NPT (MPT) DRAIN TUBE

8
PERFORMANCE DATA COOLING CAPACITIES

PERFORMANCE DATA 40LM 040~100


Water Water
Fan ESP Airflow Capacity (kW) Air Off FCU (°C)
Unit Sizes Flow Pressure
Speed
Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 597 9.18 7.46 16.5 15.2 0.39 42.7
40 Medium 50 472 7.9 6.27 15.9 14.7 0.34 32.4
Low 368 6.76 5.18 15.2 14.2 0.29 24.3
High 598 11.79 9.01 14.4 13.8 0.5 22.6
50 Medium 50 473 10.17 7.58 13.6 13.2 0.43 17.6
Low 402 9.15 6.7 13.1 12.8 0.39 14.3
High 689 14.27 10.69 14 13.5 0.61 9.1
60 Medium 50 635 13.55 10.06 13.8 13.3 0.58 8.5
Low 578 12.77 9.39 13.4 13.1 0.55 7.5
High 1115 19.19 15.05 15.7 14.6 0.82 67.1
70 Medium 50 1039 18.12 14.21 15.5 14.5 0.77 60.2
Low 957 17.14 13.35 15.3 14.4 0.73 53.8
High 1056 22.54 16.69 13.8 13.3 0.96 74.5
90 Medium 50 993 21.66 15.96 13.6 13.1 0.93 69.4
Low 913 20.55 15 13.3 12.9 0.88 63.3
High 1584 26.75 21.15 15.8 14.7 1.14 33.6
100 Medium 50 1422 26.96 19.52 15.5 14.5 1.07 31.1
Low 1200 22.47 17.26 15 14.1 0.96 24.7
TC : TOTAL HEAT CAPACITY (Kw) SHC : SENSIBLE HEAT COOLING CAPACITY (kW)

9
PERFORMANCE DATA PRESSURE DROP

40LM040

250
Water Pressure Drop (kPA)

200

150

100

50

0
0 10 20 30 40 50 60
Water Flow (l /min)

40LM050
120
Water Pressure Drop (kPA)

100

80

60

40

20

0
0 10 20 30 40 50 60 70
Water Flow (l /min)

40LM060

60
Water Pressure Drop (kPA)

50

40

30

20

10

0
0 10 20 30 40 50 60 70 80 90
Water Flow (l /min)

10
PERFORMANCE DATA COIL PRESSURE DROP

40LM070
250
Water Pressure Drop (kPA)

200

150

100

50

0
0 10 20 30 40 50 60 70 80 90
Water Flow (l /min)

40LM090
350
Water Pressure Drop (kPA)

300

250

200

150

100

50

0
0 20 40 60 80 100 120
Water Flow (l /min)

40LM100
140
Water Pressure Drop (kPA)

120

100

80

60

40

20

0
0 20 40 60 80 100 120 140
Water Flow (l /min

11
FAN PERFORMANCE

40LM040

40LM050

40LM060

12
FAN PERFORMANCE

40LM070

40LM090

40LM100

13
SOUND PRESSURE LEVEL DATA

Octave Band Centre Frequency, Hz


Model Speed
63 125 250 500 1K 2K 4K 8K dBA
H 22 32 42 45 46 42 38 28 50
040 M 20 28 36 41 42 39 33 22 46
L 19 25 32 38 39 37 28 16 43
H 22 31 38 44 48 42 37 26 50
050 M 30 29 35 41 43 39 32 20 47
L 17 24 31 40 38 35 28 15 43
H 24 35 41 47 46 43 39 28 51
060 M 21 32 37 45 43 41 36 25 49
L 16 29 35 42 40 39 34 23 46
H 27 42 44 47 46 44 39 28 52
070 M 26 37 39 45 44 42 37 27 50
L 24 32 37 42 42 40 35 24 47
H 26 36 44 44 46 44 38 26 51
090 M 25 35 32 44 45 43 37 26 50
L 24 34 42 42 45 41 35 24 49
H 30 37 46 48 51 47 42 30 55
100 M 28 35 34 45 48 45 39 29 52
L 23 34 40 43 45 43 37 25 50

Note: Sound measurement in accordance with standard JIS B8616-2006 (1.5 Meter below the unit bottom) at 8mm ESP

14
ELECTRICAL DATA

40LM - 040 40LM - 050


Nominal Pow er RPM FLA Nominal Pow er RPM FLA
Speed Pow er Input (A) Speed Pow er Input
Output (Watts) Output (Watts) (A)
(Watts) (Watts)
High 805 1098 High 764 1184

Medium 315 587 1029 2.46 Medium 315 600 1022 2.46

Low 474 930 Low 475 912

*FLA: Full Load Amps *FLA: Full LoadAmps

40LM - 060 40LM - 070


Nominal Pow er RPM FLA Nominal Pow er RPM FLA
Speed Pow er Input (A) Speed Pow er Input
Output (Watts) Output (Watts) (A)
(Watts) (Watts)
High 679 1323 High 988 1380

Medium 462 617 1278 4.4 Medium 750 859 1348 4.55

Low 563 1212 Low 766 1300

*FLA: Full Load Amps *FLA: Full LoadAmps

40LM - 090 40LM - 100


Nominal Pow er RPM FLA Nominal Pow er RPM FLA
Speed Pow er Input (A) Speed Pow er Input
Output (Watts) Output (Watts) (A)
(Watts) (Watts)
High 1070 1372 High 1610 1334

Medium 750 919 1326 4.55 Medium 800 1290 1259 7.4

Low 825 1272 Low 1120 1169


*FLA: Full LoadAmps *FLA: Full LoadAmps

15
GUIDE SPECIFICATIONS

Part 1 – GENERAL
1.1 System Description 2.4 Fan
Horizontal, furred-in, above ceiling for ducting Direct driven, double width fan wheel with forward
room fan coil unit. curved blades shall be statically and dynamically
balanced. Fan wheels shall be constructed of high
density reinforced polypropylene.
1.2 Quality Assurance
Unit shall be tested in accordance with ARI
Standard 440. Each coil shall be factory tested for 2.5 Coils
leakage at 400 psig air pressure with coil Drain pan covers entire length and width of coil till
submerged in water. Factory is ISO-9001 certified. the headers. Drain pan inside coated and outside
insulated. Standard base unit shall be equipped with
a 4-row coil for installation in a 2-pipe system. Coils
1.3 Delivery Storage and Handling shall have 9.5mm copper tubes, aluminum fins
bonded to the tubes by mechanical expansion.
Each unit shall be individually packaged from point
Each coil shall have a manual air vent and threaded
of manufacture. Units shall be handled and stored
connections field piping. Working pressure 1.72
in accordance with the manufacturer’s instructions.
Mpa, 0.105mm fin thickness and 0.24mm tube wall
thickness.

Part 2 – PRODUCTS
Equipment 2.6 Operating Characteristics
2.1 General A one coil unit installed in a 2-pipe system shall be
Factory assembled, horizontal draw through type
capable of providing cooling as determined by the
fan coil for furred-in ducted installations. Units
operating mode of the central water supply system.
shall be completed with water coil(s), fan(s),
motor(s), drain pan, filters and all required wiring,
collars for ducted units. Unit insulation and unit’s
drain pan insulation are UL94 compliance. 2.7 Electrical Requirements
Standard unit shall operate on 230V±10%, single
phase, 50Hz electric power.
2.2 40LM Furred-in Units
Base 40LM unit with factory installed plenum
section and cleanable filter as shown on 2.8 Motor(s)
equipment drawings. The plenum shall be rear air Fan motors shall be 3-speed, 230V, single phase,
return. Shall enclose the fan/motor assemblies, 50Hz permanent split capacitor type, with ball type
and shall be lined with 12.7mm thick PU insulation bearings and over-sized oil reservoirs to ensure
20kg/m³ density and 6.0mm PE insulation lubrication. The fan motor(s) shall be equipped with
28.6kg/m³ density on the drain pan. Unit shall integral automatic temperature reset for motor
have a removable panel to provide access to protection. Motor insulation is Class E and motor is
fan/motor assemblies and unit identification label. open drip proof type.

2.3 40LM Horizontal Base Unit with Plenum 2.9 Filter


for Concealed Installations Permanent washable synthetic media filters with
Unit has a factory installed, galvanized steel 12mm thick and G2 filter class as per European
plenum section and one-in permanent filter. The Union EN779
plenum shall be rear return, lined with 12.7mm PU
insulation 20kg/m³ and 6.0mm PE insulation
28.6kg/m³ on the drain pan, and include a
removable panel to provide access to the
fan/motor assembly.

16
Carrier International Sdn. Bhd. (3385-T)
Lot 4, Jalan P/6, 43650 Bandar Baru Bangi,
Selangor Darul Ehsan, Malaysia.
Tel: 03-8913 7600

40LM1 REV-6

01 2015

Manufacturer reserves the right to discontinue, or


change at any time, specifications or designs
40LM1-A15-7PD SUPERCEDES 40LM-G12-5PD without notice and without incurring obligations.

40LM1-A15-7PD
42C/D SERIES
Ducted Chilled Water Fan Coil Unit
With District Cooling Application
(300 to 2000 CFM)

42DF

42CGT

42DE

42CET

42DC

MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT

Copyright © 2013 Carrier International Sdn Bhd.


MODEL NUMBER NOMENCLATURE

MODEL : 42CET/CED
4 2 C E T 0 0 3 4 - - 7 2 1 2 5
CISB Code
42 series 25 — AC Motor
Fan Coil Unit E5 — EC Motor

Packing Method
Model 1 — Standard Packing
CE — Furred-in Ceiling
model with plenum Development Series
0 — 42CET/CED (EC motor)
2 — 42CET/CED (AC motor)
T — Standard application
D — District Cooling application Electrical Characteristics
7 — 220/240V-1PH-50Hz

Piping Handling
Unit Size (Airflow, cfm) - — Left
003 — 300 R — Right
004 — 400
005 — 500 - — Opposite end connection
006 — 600 K — Same end connection
008 — 800
010 — 1000 Coil
012 — 1200 3 — 3 row coil
* 014 — 1400 4 — 4 row coil

Note:
* Not applicable for EC motor.

COMPUTER SELECTION
We have made available a computer program to finalize your selections.
Please contact your Carrier representative for a computer selection based on
your “Quick Selection” plus the design parameters of your application.

TABLE OF CONTENTS
Page
Model Number Nomenclature………………………………………..……………………..……...... 2 - 3
Product Features………………………………………………………….………………………………. 4
Technical Data…………………………………………………………………………………….…. 5 - 15
Unit Dimension and Weight………………………………………………………………...….…... 16 - 20
Performance Rating………………………………………………………………………….….…..
g 21 - 26
Electrical Data……………………………………………………………………………….………. 27 - 28
Wiring Diagram……………………………………………………………………………….………29 - 31
Guide Specifications…………………………………………………………….………………….. 32 - 33

2
MODEL NUMBER NOMENCLATURE

MODEL : 42CGT/CGD
4 2 C G T 0 0 3 4 - - 7 0 1 2 5

42 series CISB Code


Fan Coil Unit 25 — AC Motor

Packing Method
Model 1
CG — Cabinet model
Development Series
0 — 42CGT, 42CGD
T — Standard Application
D — District Cooling Application Electrical Characteristics
7 — 220/240V-1Ph-50Hz

Unit Size (Airflow, cfm) Piping Handling


003 — 300 - — Left Handling
004 — 400 R — Left Handling
005 — 500
006 — 600 Not used
008 — 800
010 — 1000 Coil
012 — 1200 4 — 4 row coil

MODEL : 42D SERIES


4 2 D C - 0 1 0 4 - - 7 5 1 2 5
CISB Code
25 — AC Motor
E5 — EC Motor
42 series Fan Coil Unit
Packing Method
1 — Standard Packing
Model
DC — Furred-in Ceiling model Development Series
* DE — Ceiling model with painted 1 — 42DC/DCD (EC motor)
galvanized full casing 3 — 42DF/DFD (AC motor)
* DF — Exposed Ceiling Cabinet model 4 — 42DE/DED (AC motor)
5 — 42DC/DCD (AC motor)
- — Standard application
D — District Cooling application Electrical Characteristics
7 — 220/240V-1Ph-50Hz

Unit Size (Airflow, cfm) Piping Handling


006 — 600 - — Left
008 — 800 R — Right
010 — 1000
012 — 1200 - — Opposite end connection
014 — 1400 ** K — Same end connection
016 — 1600
018 — 1800 Coil
020 — 2000 4 — 4 row coil

Note:
* Not aplicable for EC motor.
** Applicable for 42DC/DCD model only.

3
PRODUCT FEATURES

If fan coil terminals are the answer to your job requirements, you can’t afford to pass
over Carrier’s versatile and extensive range of fan coil units.

With Carrier’s 42 series fan coil units, you can select furred-in or cabinet style, in capacities from 300 to 2,000
cfm. Units are ideal for installations in residential, hotels, motels, apartments, offices, hospitals, schools and
other multi-room buildings.

Carrier room fan coil terminals provide unsurpassed year round comfort, with high cooling performance.
Carrier 42 series terminal requires very little space and is easy to install. Piping, drain and wiring connections
are readily accessible to save installation time and field labor expense.

Forget about expensive ductwork, forget about complex system controls, forget the aggravation and choose
Carrier’s easy to install room fan coil units – in pipe systems. Opt for quiet. Carrier room fan coil units
operate at exceptionally low sound levels. Generous amount of insulation absorbs operating sound and
rugged, rigid construction ensures vibration free operation at all fan speeds.

Carrier room fan coil units are economical. Three speed fans deliver just the right amount of conditioned air
for your comfort needs at any load. And each individual unit can be shut off when not in use. Permanent Split
Capacitor motors deliver peak operating efficiency. In choosing Carrier units, you can match your application
with a wide range of custom-designed options and accessories.

When you go for Carrier 42 series, the advantages to owner, installer and the room occupants are too great to
ignore.

Carrier 42 series fan coils give you design and Save operating costs with Carrier fan coils
equipment location flexibility • Higher efficiency & reliability Electronically
• Wide range of popular capacities, 300 – 2000 cfm Commuted Motor (42CET/CED, DC/DCD) -
• Available up to 11 sizes. optional.
• Cabinet or furred-in units • Individual unit shut-off when not in use
• Choose from numerous control systems • Efficient, 3 speed centrifugal fans
• Select 3 row coils (42CET), 4 row coils (42CET, • Permanent Split Capacitor motors
CGT, DC, DE & DF) • High efficiency heat transfer surface
• Accommodates 2 pipe systems
• Fully insulated/low fan speed means quiet operation Carrier fan coils save your service and
• Draw outside air for odor dilution maintenance expense
• Uses only minimal space • Nationwide Carrier service
• Insulated drain pan
Select Carrier fan coils for easy, low cost installation • Easy access to components
• Easy wiring, piping connections • Rugged construction
• Mounting holes, slots speed hanging • Factory leak test for coil
• Requires
R i no expensive
i d ductwork
k • Cleanable
C f
filters
• Ideal for new construction or renovation • Long life, heavy duty bearings

4
TECHNICAL DATA

42CET Furred-in Ceiling FCU with Plenum


3 Rows at nominal CFM
MODEL: 42CET
PERFORMANCE
003 004 005 006 008 010 012 014
Nominal CFM 300 400 500 600 800 1000 1200 1400
High
Air Volume ℓ/s 142 189 236 283 378 472 566 661
kW 3.07 3.97 4.34 4.79 7.26 7.89 9.76 10.95
Cooling Capacity (Fluid)*
Btu/hr 10,474 13,539 14,808 16,341 24,766 26,909 33,296 37,352
Motor nominal power output W 32 45 70 72 55 (x2) 70 (x2) 72 (x2) 70 (x3)
Motor current Amp - Refer to page 27 -
High 37 4
37.4 37 9
37.9 39 8
39.8 41 7
41.7 42 2
42.2 43 5
43.5 44 9
44.9 46 4
46.4
Sound
Med dB(A) 34.9 35.8 37.4 38.9 40.1 41.7 43.0 44.7
Pressure **
Low 33.4 33.9 35.2 37.2 37.4 39.2 39.6 41.7
Water Flow ℓ/s 0.13 0.17 0.19 0.20 0.31 0.34 0.42 0.47
Water Pressure Drop kPa 15.6 34.6 20.2 21.3 21.0 22.8 28.2 37.6
Fan Type Centrifugal Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 3
Coil
Working Pressure 1.72MPa
In-Out (Thread)/ Material ¾” FPT (BSP) / Brass
Connections
Condensate Drain / Material ¾” MPT (BSP) / Steel
Height mm 241.4
Cabinet Size Width mm 556.8
Length mm 770 890 970 1,170 1,410 1,530 1,770 2,010
Casing Material / Thickness Galvanized Steel / 0.8 & 1.0mm
Casing Treatment / External Finish Non-painted / -
Net Weight kg 16.5 19.1 19.7 22.6 31.1 34.5 39.4 46.3

NOTE:
* Based on motor at high speed, standard air and dry coil operation; 5.6˚C water temperature rise; entering air temperature 26.7˚C DB;
19.4˚C WB; Entering water temperature 7.2˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

Electronically Commuted Motor (ECM) is available for unit size 003 to 012 - optional.

LT101
Controller

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

5
TECHNICAL DATA (cont’)

42CET Furred-in Ceiling FCU with Plenum


4 Rows at nominal CFM

MODEL: 42CET
PERFORMANCE
003 004 005 006 008 010 012 014
Nominal CFM 300 400 500 600 800 1000 1200 1400
High
Air Volume ℓ/s 142 189 236 283 378 472 566 661
kW 3.38 4.25 4.58 4.99 7.55 8.58 11.5 13.53
Cooling Capacity (Fluid)*
Btu/hr 11,530 14,486 15,637 17,009 25,758 29,270 39,232 46,157
Motor nominal power output W 32 45 70 72 55 (x2) 70 (x2) 72 (x2) 70 (x3)
Motor current Amp - Refer to page 27 -
High 37.1 37.4 39.1 40.4 41.3 43.1 43.4 43.6
Sound
Med dB(A) 34.6 34.9 35.7 38.8 38.8 40.8 39.9 41.8
Pressure **
Low 33.0 32.1 32.4 35.4 34.6 37.2 37.6 39.9
Water Flow ℓ/s 0.14 0.18 0.20 0.21 0.32 0.37 0.49 0.58
Water Pressure Drop kPa 13.5 23.8 17.6 9.3 17.4 24.5 30.8 46.4
yp
Fan Type Centrifugal
g Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72 MPa
In-Out (Thread) / Material ¾” FPT (BSP) / Brass
Connections
Condensate Drain / Material ¾” MPT (BSP) / GI Steel
Height mm 241 4
241.4
Cabinet Size Width mm 556.8
Length mm 770 890 970 1,170 1,410 1,530 1,770 2,010
Casing Material / Thickness Galvanized Steel / 0.8 & 1.0mm
Casing Treatment / External Finish Non-painted / -
Net Weight kg 17.8 20.5 21.7 23.7 33.0 36.7 42.0 49.1
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 5.6˚C water temperature rise; entering air temperature 26.7˚C DB;
19.4˚C WB; Entering water temperature 7.2˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

Electronically Commuted Motor (ECM) is available for unit size 003 to 012 - optional.

LT101
Controller

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

6
TECHNICAL DATA (cont’)

42CED Furred-in Ceiling FCU with Plenum


4 Rows at nominal CFM

MODEL: 42CED (District Cooling Application)


PERFORMANCE
003 004 005 006 008 010 012 014
Nominal CFM 300 400 500 600 800 1000 1200 1400
High
Air Volume ℓ/s 142 189 236 283 378 472 566 661
kW 2.32 3.13 3.40 3.84 5.64 5.99 7.22 8.27
Cooling Capacity (Fluid)*
Btu/hr 7,930 10,685 11,614 13,088 19,245 20,454 24,645 28,227
Motor nominal power output W 32 45 70 72 55 (x2) 70 (x2) 72 (x2) 70 (x3)
Motor current Amp - Refer to page 27 -
High 37.1 37.4 39.1 40.4 41.3 43.1 43.3 43.6
Sound
Med dB(A) 34.6 34.9 35.7 38.8 38.8 40.8 39.9 41.8
Pressure **
Low 33.0 32.1 32.4 35.4 34.6 37.2 37.6 39.9
Water Flow ℓ/s 0.06 0.08 0.09 0.10 0.15 0.16 0.19 0.22
Water Pressure Drop kPa 4.8 10.4 6.1 5.9 12.9 15.8 9.5 13.7
yp
Fan Type Centrifugal
g Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72MPa
In-Out (Thread) / Material ¾” FPT (BSP) / Brass
Connections
Condensate Drain / Material ¾” MPT (BSP) / GI Steel
Height mm 241 4
241.4
Cabinet Size Width mm 556.8
Length mm 770 890 970 1,170 1,410 1,530 1,770 2,010
Casing Material / Thickness Galvanized Steel / 0.8 & 1.0mm
Casing Treatment / External Finish Non-painted / -
Net Weight kg 17.8 20.5 21.7 23.7 33.0 36.7 42.0 49.1
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 8.9˚C water temperature rise; entering air temperature 24.4˚C DB;
17.2˚C WB; Entering water temperature 5.5˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

Electronically Commuted Motor (ECM) is available for unit size 003 to 012 - optional.

LT101
Controller

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

7
TECHNICAL DATA (cont’)

42CGT Horizontal Cabinet Model


4 Rows at nominal CFM

MODEL: 42CGT
PERFORMANCE
003 004 005 006 008 010 012
Nominal CFM 300 400 500 600 800 1000 1200
High
Air Volume ℓ/s 142 182 236 283 378 472 566
kW 3.34 4.64 5.64 5.91 8.38 11.47 13.04
Cooling Capacity (Fluid)*
Btu/hr 11,388 15,842 19,242 20,153 28,585 39,151 44,487
Motor nominal power output W 35 48 68 75 58 (x2) 75 (x2) 78 (x3)
Motor current Amp - Refer to page 27 -
High 44.3 43.6 44.5 46.0 49.1 49.5 50.1
Sound
Med dB(A) 42.3 41.5 41.7 41.0 45.5 45.6 48.4
Pressure **
Low 40.2 39.0 38.6 40.5 41.8 40.2 44.3
Water Flow ℓ/s 0.14 0.20 0.24 0.25 0.36 0.49 0.56
Water Pressure Drop kPa 12.7 22.6 46.9 8.8 21.6 47.3 48.1
yp
Fan Type Centrifugal
g Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.6MPa
In-Out (Sweat) / Material 3/4” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 310
Cabinet Size Width mm 582
Length mm 1,030 1,150 1,230 1,350 1,670 2,030 2,270
Casing Material / Thickness Galvanized Steel / 0.9 & 1.0 mm
Casing Treatment / External Finish Powder Painted / Morning Mist
Net Weight kg 39.7 44.6 46.9 50.9 65.0 79.8 90.7
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 5.6˚C water temperature rise; entering air temperature
23.89˚C DB; 17.2˚C WB; Entering water temperature 7.2˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

8
TECHNICAL DATA (cont’)

42CGD Horizontal Cabinet Model


4 Rows at nominal CFM

MODEL: 42CGD (District Cooling Application)


PERFORMANCE
003 004 005 006 008 010 012
Nominal CFM 300 400 500 600 800 1000 1200
High
Air Volume ℓ/s 142 182 236 283 378 472 566
kW 2.28 3.12 3.89 4.07 5.92 7.91 8.36
Cooling Capacity (Fluid)*
Btu/hr 7,776 10,629 13,259 13,884 20,209 26,991 28,514
Motor nominal power output W 35 48 68 75 58 (x2) 75 (x2) 78 (x3)
Motor current Amp - Refer to page 27 -
High 44.3 43.6 44.5 46.0 49.1 49.5 50.1
Sound
Med dB(A) 42.3 41.5 41.7 41.0 45.5 45.6 48.4
Pressure **
Low 40.2 39.0 38.6 40.5 41.8 40.2 44.3
Water Flow ℓ/s 0.06 0.08 0.10 0.11 0.16 0.21 0.22
Water Pressure Drop kPa 7.6 14.8 27.5 6.7 23.5 21.0 14.4
yp
Fan Type Centrifugal
g Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.6MPa
In-Out (Sweat) / Material 3/4” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 310
Cabinet Size Width mm 582
Length mm 1,030 1,150 1,230 1,350 1,670 2,030 2,270
Casing Material / Thickness Galvanized Steel / 0.9 & 1.0 mm
Casing Treatment / External Finish Powder Painted / Morning Mist
Net Weight kg 39.7 44.6 46.9 50.9 65.0 79.8 90.7
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 8.9˚C water temperature rise; entering air temperature
24.4˚C DB; 17.2˚C WB; Entering water temperature 5.5˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

9
TECHNICAL DATA (cont’)

42DC Furred-in Ceiling FCU with Plenum


4 Rows at nominal CFM

MODEL: 42DC
PERFORMANCE
006 008 010 012 014 016 018 020
Nominal
N i l CFM 600 800 1000 1200 1400 1600 1800 2000
High
Air Volume ℓ/s 283 378 472 566 661 755 852 943
kW 6.57 7.88 9.94 12.39 14.10 17.71 19.03 20.42
Cooling Capacity (Fluid)*
Btu/hr 22,404 26,890 33,900 42,291 48,106 60,427 64,924 69,688
Motor nominal power output W 120 200 120 (x2) 300 450
Motor current Amp - Refer to page 27 -
High 40.3 42.0 48.4 47.2 49.2 48.6 48.9 49.7
Sound
Med dB(A) 38.3 38.9 44.8 43.1 46.4 46.9 47.6 48.1
Pressure **
Low 35.5 36.5 38.6 39.8 44.6 44.8 44.7 45.6
Water Flow ℓ/s 0.28 0.34 0.42 0.53 0.60 0.76 0.81 0.87
Water Pressure Drop kPa 25.6 33.3 52.7 85.7 82.0 114.6 96.6 117.6
Fan Type Centrifugal Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72 MPa
In-Out (Sweat) / Material 5/8” / Copper 1” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 416 3
416.3
Cabinet Size Width mm 762.4
Length mm 641 768 870 997 1,124 1,251 1,378 1,479
Casing Material / Thickness Galvanized Steel / 1.0 mm
Casing Treatment / External Finish Non-painted / -
Net Weight kg 39 44 63 72 75 76 83 95
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 5.6˚C water temperature rise; entering air temperature 26.7˚C DB;
19.4˚C WB; Entering water temperature 7.2˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

Electronically Commuted Motor (ECM) is available for all sizes - optional.

LT101
Controller

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

10
TECHNICAL DATA (cont’)

42DCD Furred-in Ceiling FCU with Plenum


4 Rows at nominal CFM

MODEL: 42DCD (District Cooling Application)


PERFORMANCE
006 008 010 012 014 016 018 020
Nominal
N i l CFM 600 800 1000 1200 1400 1600 1800 2000
High
Air Volume ℓ/s 283 378 472 566 661 755 852 943
kW 4.89 6.68 8.02 9.50 11.2 14.26 15.15 15.76
Cooling Capacity (Fluid)*
Btu/hr 16,678 22,785 27,375 32,416 38,215 48,650 51,681 53,757
Motor nominal power output W 120 200 120 (x2) 300 450
Motor current Amp - Refer to page 28 -
High 40.3 42.0 48.4 47.2 49.2 48.6 48.9 49.7
Sound
Med dB(A) 38.3 38.9 44.8 43.1 46.4 46.9 47.6 48.1
Pressure **
Low 35.5 36.5 38.6 39.8 44.6 44.8 44.7 45.6
Water Flow ℓ/s 0.13 0.18 0.22 0.26 0.30 0.38 0.41 0.42
Water Pressure Drop kPa 26.8 55.2 53.5 47.4 41.7 55.1 62.6 55.5
Fan Type Centrifugal Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72 MPa
In-Out (Sweat) / Material 5/8” / Copper 1” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 416 3
416.3
Cabinet Size Width mm 762.4
Length mm 641 768 870 997 1,124 1,251 1,378 1,479
Casing Material / Thickness Galvanized Steel / 1.0 mm
Casing Treatment / External Finish Non-painted / -
Net Weight kg 39 44 63 72 75 76 83 95
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 8.9˚C water temperature rise; entering air temperature 24.4˚C DB;
17.2˚C WB; Entering water temperature 5.5˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

Electronically Commuted Motor (ECM) is available for all sizes - optional.

LT101
Controller

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

11
TECHNICAL DATA (cont’)

42DE Ceiling Model with Double Skin Galvanized Full Casing


4 Rows at nominal CFM

MODEL: 42DE
PERFORMANCE
006 008 010 012 014 016 018 020
Nominal
N i l CFM 600 800 1000 1200 1400 1600 1800 2000
High
Air Volume ℓ/s 283 378 472 566 661 755 852 943
kW 6.53 7.85 9.78 12.03 15.23 17.03 19.62 20.51
Cooling Capacity (Fluid)*
Btu/hr 22,286 26,769 33,367 41,063 51,963 58,118 66,954 69,969
Motor nominal power output W 120 200 120 (x2) 300 450
Motor current Amp - Refer to page 28 -
High 44.1 41.1 47.6 47.6 47.6 54.3 51.8 52.1
Sound
Med dB(A) 41.2 38.5 45.5 44.5 44.8 52.8 49.5 49.4
Pressure **
Low 37.6 34.8 40.6 42.4 41.0 47.6 45.3 45.2
Water Flow ℓ/s 0.28 0.33 0.42 0.51 0.65 0.73 0.84 0.88
Water Pressure Drop kPa 17.5 23.9 30.1 38.7 34.9 46.8 29.7 33.5
Fan Type Centrifugal Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72 MPa
In-Out (Sweat) / Material 5/8” / Copper 7/8” / Copper 1 1/8” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 479
Cabinet Size Width mm 965
Length mm 787 914 1,016 1,143 1,270 1,397 1,524 1,626
Casing Material / Thickness Galvanized Steel / 1.0 mm
Casing Treatment / External Finish Powder Painted / Morning Mist
Net Weight kg 62 71 78 89 95 101 110 114
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 5.6˚C water temperature rise; entering air temperature 26.7˚C DB;
19.4°C WB; Entering water temperature 7.2˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

12
TECHNICAL DATA (cont’)

42DED Ceiling Model with Double Skin Galvanized Full Casing


4 Rows at nominal CFM

MODEL: 42DED (District Cooling Application)


PERFORMANCE
006 008 010 012 014 016 018 020
Nominal
N i l CFM 600 800 1000 1200 1400 1600 1800 2000
High
Air Volume ℓ/s 283 378 472 566 661 755 852 943
kW 4.86 6.39 7.86 9.33 11.85 13.60 14.83 15.05
Cooling Capacity (Fluid)*
Btu/hr 16,566 21,789 26,820 31,820 40,423 46,402 50,590 51,355
Motor nominal power output W 120 200 120 (x2) 300 450
Motor current Amp - Refer to page 28 -
High 44.1 41.1 47.6 47.6 47.6 54.3 51.8 52.1
Sound
Med dB(A) 41.2 38.5 45.5 44.5 44.8 52.8 49.5 49.4
Pressure **
Low 37.6 34.8 40.6 42.4 41.0 47.6 45.3 45.2
Water Flow ℓ/s 0.13 0.17 0.21 0.25 0.32 0.37 0.40 0.40
Water Pressure Drop kPa 15.1 30.1 50.2 18.7 30.1 42.6 53.7 35.2
Fan Type Centrifugal Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72 MPa
In-Out (Sweat) / Material 5/8” / Copper 7/8” / Copper 1 1/8” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 479
Cabinet Size Width mm 965
Length mm 787 914 1,016 1,143 1,270 1,397 1,524 1,626
Casing Material / Thickness Galvanized Steel / 1.0 mm
Casing Treatment / External Finish Powder Painted / Morning Mist
Net Weight kg 62 71 78 89 95 101 110 114
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 8.9˚C water temperature rise; entering air temperature 24.4˚C DB;
17.2˚C WB; Entering water temperature 5.5˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

13
TECHNICAL DATA (cont’)

42DF Exposed Ceiling Cabinet Model


4 Rows at nominal CFM

MODEL: 42DF
PERFORMANCE
006 008 010 012 014 016 018 020
Nominal
N i l CFM 600 800 1000 1200 1400 1600 1800 2000
High
Air Volume ℓ/s 283 378 472 566 661 755 852 943
kW 5.07 7.20 8.82 10.62 12.67 14.49 17.48 19.59
Cooling Capacity (Fluid)*
Btu/hr 17,282 24,577 30,102 36,235 43,227 49,450 59,635 66,856
Motor nominal power output W 80 120 80 (x2) 120 (x2) 200 (x2)
Motor current Amp - Refer to page 28 -
High 44.1 41.1 47.6 47.6 47.6 54.3 51.8 52.1
Sound
Med dB(A) 41.2 38.5 45.5 44.5 44.8 52.8 49.5 49.4
Pressure **
Low 37.6 34.8 40.6 42.4 41.0 47.6 45.3 45.2
Water Flow ℓ/s 0.22 0.31 0.38 0.45 0.54 0.62 0.75 0.84
Water Pressure Drop kPa 10.6 20.9 24.6 31.3 25.7 35.0 24.2 30.8
Fan Type Centrifugal Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72 MPa
In-Out (Sweat) / Material 5/8” / Copper 7/8” / Copper 1 1/8” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 479
Cabinet Size Width mm 965
Length mm 787 914 1,016 1,143 1,270 1,397 1,524 1,626
Casing Material / Thickness Galvanized Steel / 1.0 mm
Casing Treatment / External Finish Powder Painted / Morning Mist
Net Weight kg 59 66 73 82 88 96 103 108
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 5.6˚C water temperature rise; entering air temperature 26.7˚C DB;
19.4˚C WB; Entering water temperature 7.2˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

14
TECHNICAL DATA (cont’)

42DFD Exposed Ceiling Cabinet Model


4 Rows at nominal CFM

MODEL: 42DFD (District Cooling Application)


PERFORMANCE
006 008 010 012 014 016 018 020
Nominal
N i l CFM 600 800 1000 1200 1400 1600 1800 2000
High
Air Volume ℓ/s 283 378 472 566 661 755 852 943
kW 4.19 5.86 7.09 8.23 9.86 11.57 13.21 14.38
Cooling Capacity (Fluid)*
Btu/hr 14,286 20,005 24,196 28,079 33,627 39,482 45,060 49,070
Motor nominal power output W 80 120 80 (x2) 120 (x2) 200 (x2)
Motor current Amp - Refer to page 28 -
High 44.1 41.1 47.6 47.6 47.6 54.3 51.8 52.1
Sound
Med dB(A) 41.2 38.5 45.5 44.5 44.8 52.8 49.5 49.4
Pressure **
Low 37.6 34.8 40.6 42.4 41.0 47.6 45.3 45.2
Water Flow ℓ/s 0.11 0.16 0.19 0.22 0.26 0.31 0.36 0.39
Water Pressure Drop kPa 11.2 26.1 41.9 15.2 21.7 31.4 43.5 31.7
Fan Type Centrifugal Forward-curved blades
Motor Type Permanent Split Capacitor
No. of Row 4
Coil
Working Pressure 1.72 Mpa
In-Out (Sweat) / Material 5/8” / Copper 7/8” / Copper 1 1/8” / Copper
Connections
Condensate Drain / Material 7/8” / GI Steel
Height mm 479
Cabinet Size Width mm 965
Length mm 787 914 1,016 1,143 1,270 1,397 1,524 1,626
Casing Material / Thickness Galvanized Steel / 1.0 mm
Casing Treatment / External Finish Powder Painted / Morning Mist
Net Weight kg 59 66 73 82 88 96 103 108
NOTE:
* Based on motor at high speed, standard air and dry coil operation; 8.9˚C water temperature rise; entering air temperature 24.4˚C DB;
17.2˚C WB; Entering water temperature 5.5˚C.
** Sound measurement in accordance with Standard JIS8616-2006 (1.5m below the unit bottom).

- - For other design conditions, please apply the selection program to finalize your applications - -

Performance Assurance
Rated in accordance with
ARI Standard 440-2008

15
UNIT DIMENSIONS AND WEIGHT

42CET/CED Furred-in Ceiling FCU with Plenum

335 4-12 x 22 mm

27.4

164.0

TOP VIEW 558.0


FILTER
CONTROL
BOX 13.0

55

128.4
223 118.5 241.5

272 23

FRONT VIEW HEADER VIEW

MODEL DIMENSIONS (mm) NET WEIGHT (kg)


42CET/CED A B C 3 Rows 4 Rows
003 636 770 600 16.5 17.8
004 756 890 720 19.1 20.5
005 836 970 800 19.7 21.7
006 956 1170 1000 22.6 23.7
008 1276 1410 1240 31 1
31.1 33 0
33.0
010 1396 1530 1360 34.5 36.7
012 1636 1770 1600 39.4 42.0
014 1876 2010 1840 46.3 49.1

16
UNIT DIMENSIONS AND WEIGHT (cont’)

42CGT/CGD Horizontal Cabinet Unit

A
101

C B C

582
422

FRONT VIEW
59

49 47
TOP PANEL

30

110

310

BACK PANEL
RIGHT SIDE VIEW

104

71

61

257 259

218
220.0
165
141

85 82

79.0

D 40
E E BACK PANEL DETAIL

67 (TYPICAL BOTH SIDES)


BOTTOM VIEW OF ACCESS PANEL
CONTROL BOX 92

UNIT SIZE DIMENSIONS (mm) NET WEIGHT


42CGT A B C D G (kg)
003 1030 658 186 881 74 39.7
004 1150 769 190 881 134 44.6
005 1230 880 175 881 174 46.9
006 1350 992 179 1102 123 50.9
008 1670 1325 172 1325 172 65.0
010 2030 1659 185 1325 352 79.8
012 2270 1882 193 1548 360 90.7

17
UNIT DIMENSIONS AND WEIGHT (cont’)

42DC/DCD Furred-in ceiling FCU with Plenum

F
F
D
D

683 683

C C
183.4 183.4

114 B 114
32 32 114 B 114
A
A
36
13 142
64
104

134
268
306
402 356

583.7 423 FILTER


REMOVAL

MTG
HOLE
CONTROL
BOX

683

183.4 C

32 114 B 114

UNIT SIZE DIMENSION (mm) NET WEIGHT


42DC/DCD A B C D E F (kg)
006 584 356 381 432 533 641 41
008 711 483 508 559 660 768 46
010 813 584 610 660 762 870 66
012 940 711 737 737 889 997 74
014 1067 838 864 914 1016 1124 76
016 1194 965 991 1041 1143 1251 77
018 1321 1092 1178 1168 1270 1378 83
020 1422 1194 1219 1270 1372 1479 94

18
UNIT DIMENSIONS AND WEIGHT (cont’)

42DE/DED Furred-in ceiling FCU with Plenum

76

65

C F

CONTROL
BOX

A B D E

C F

813
965

TOP VIEW

20
FILTER (Dimension shown are all in mm)

33
67

66 197

322 64
460 356 391
22mm DIA KO 64
E 64
38mm DIA KO
66
98
44

57 77 77
49 RIGHT SIDE VIEW REAR PANEL ELEVATION

UNIT SIZE DIMENSIONS (mm) NET WEIGHT


42DE/DED A B C D E F (kg)
006 787 381 203 381 381 203 62
008 914 508 203 508 508 203 71
010 1016 610 203 610 610 203 78
012 1143 737 203 737 737 203 89
014 1270 837 203 837 837 203 95
016 1397 991 203 991 991 203 101
018 1524 1118 203 1118 1118 203 110
020 1626 1219 203 1219 1219 203 114

19
UNIT DIMENSIONS AND WEIGHT (cont’)

42DF/DFD Furred-in ceiling FCU with Plenum

76

65

C F

CONTROL BOX

A B D E

C F

812 76
965

TOP VIEW

20 (Dimension shown are all in mm)

67

66

322 64
460 356
22mm DIA KO 64

64
38mm DIA KO
66
98

FILTER 36
76.9
RIGHT SIDE VIEW REAR PANEL ELEVATION
(TYP)

UNIT SIZE DIMENSIONS (mm) NET WEIGHT


42DF/DFD A B C D E F (kg)
006 787 343 222 381 356 216 59
007 914 470 222 508 508 203 66
010 1016 572 222 610 610 203 73
012 1143 699 222 737 737 216 82
014
0 1270
0 826
8 6 222 864
86 864
86 203
03 88
016 1397 953 222 991 991 216 96
018 1524 1078 222 1118 1118 203 103
020 1626 1181 222 1219 1219 203 108

20
PERFORMANCE RATING

42CET Furred-in Ceiling Model (3-Rows)


Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42CET Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 122 3.07 2.07 12.9 12.1 0.13 15.6
003 Medium 50 89 2.56 1.62 11.8 10.8 0.11 10.8
Low 54 1.69 1.05 10.7 9.8 0.07 4.8
High 162 3.97 2.56 13.8 12.3 0.17 34.6
004 Medium 50 115 3.27 1.97 12.7 10.9 0.14 23.8
L
Low 71 2 18
2.18 1 28
1.28 11 9
11.9 10 0
10.0 0 09
0.09 10 6
10.6
High 189 4.34 3.08 13.4 12.8 0.19 20.2
005 Medium 50 141 3.71 2.46 12.5 11.7 0.16 14.7
Low 103 2.82 1.90 11.7 11.3 0.12 8.5
High 245 4.79 3.28 15.7 13.9 0.20 21.3
006 Medium 50 190 4.13 2.69 15.1 13.2 0.18 16.4
Low 145 3.40 2.17 14.5 12.6 0.15 11.1
High 332 7.26 4.91 14.6 13.1 0.31 21.0
008 Medium 50 235 5.96 3.76 13.6 12.0 0.25 14.4
Low 150 4.09 2.60 12.5 11.3 0.17 6.9
High 369 7.89 5.40 14.7 14.3 0.34 22.8
010 Medium 50 271 6.58 4.25 13.9 12.4 0.28 16.6
Low 182 4.68 3.01 13.2 11.8 0.20 8.5
High 498 9.76 6.99 15.2 13.8 0.42 28.2
012 Medium 50 411 8.70 6.03 14.7 13.4 0.37 23.6
Low 311 7.27 4.84 14.0 12.6 0.31 16.9
High 514 10.95 7.49 14.8 13.3 0.47 37.6
014 Medium 50 430 9.93 6.53 14.3 12.7 0.42 32.0
Low 343 8.37 5.43 13.8 12.3 0.36 23.8
NOTE: Air Conditions: EDB/EWB 26.7/19.4°C * Water Conditions: EWT/LWT 7.2/12.8˚C ∆T: 5.6˚C
* As per AHRI 440 Standard Cooling Rating 80.0°F (26.7ºC) dry bulb, 67.0ºF(19.4ºC) wet-bulb and entering water temp 45ºF (7.2ºC).

42CET Furred-in Ceiling Model (4-Rows)


Model ESP Air Flow Capacity (kW) Air off FCU ((°C)
C) Water Flow Water Pressure
Speed
42CET (Pa) (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 118 3.38 2.11 12.1 10.9 0.14 13.5
003 Medium 50 83 2.76 1.60 11.0 9.2 0.12 9.0
Low 51 1.84 1.02 10.3 8.1 0.08 4.0
High 156 4.25 2.61 13.0 11.3 0.18 23.8
004 Medium 50 112 3.53 2.02 12.0 9.8 0.15 16.5
Low 67 2.32 1.26 11.4 8.7 0.10 7.2
Hi h
High 183 4 58
4.58 3 05
3.05 13 1
13.1 12 1
12.1 0 20
0.20 17 6
17.6
005 Medium 50 137 3.88 2.44 12.2 10.9 0.17 12.6
Low 102 2.99 1.91 11.4 10.6 0.13 7.6
High 235 4.99 3.50 14.5 13.3 0.21 9.3
006 Medium 50 185 4.36 2.91 13.8 12.6 0.19 7.1
Low 139 3.49 2.31 13.1 12.0 0.15 4.6
High 328 7.55 5.25 13.6 12.7 0.32 17.4
008 Medium 50 230 6.18 3.99 12.5 11.4 0.26 11.9
Low 148 4.26 2.77 11.4 10.8 0.18 5.7
High 360 8.58 5.68 13.8 12.5 0.37 24.5
010 Medium 50 269 7.19 4.51 13.0 11.5 0.31 17.5
Low 178 5.08 3.14 12.3 10.8 0.22 9.0
High 471 11.50 7.51 13.7 12.3 0.49 30.8
012 Medium 50 393 10.36 6.52 13.2 11.6 0.44 25.3
Low 299 8.56 5.24 12.4 10.8 0.37 17.8
High 510 13.53 8.72 12.7 11.6 0.58 46.4
014 Medium 50 432 12.36 7.67 12.2 10.9 0.53 40.1
Low 346 10.46 6.40 11.6 10.3 0.45 29.1
NOTE: Air Conditions: EDB/EWB 26.7/19.4°C * Water Conditions: EWT/LWT 7.2/12.8˚C ∆T: 5.6˚C
* As per AHRI 440 Standard Cooling Rating 80.0°F (26.7ºC) dry bulb, 67.0ºF(19.4ºC) wet-bulb and entering water temp 45ºF (7.2ºC).

- - For other design conditions, please apply the selection program to finalize your applications - -
21
PERFORMANCE RATING (cont’)

42CED Furred-in Ceiling Model (4-Rows) – District Cooling Application


Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42CED Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 118 2.32 1.67 12.9 11.1 0.06 4.8
003 Medium 50 83 1.90 1.27 11.9 9.9 0.05 3.5
Low 51 1.26 0.81 11.4 9.2 0.03 2.1
High 156 3 13
3.13 2 24
2.24 12 6
12.6 10 9
10.9 0 08
0.08 10 4
10.4
004 Medium 50 112 2.60 1.74 11.7 9.8 0.07 7.3
Low 67 1.71 1.09 11.2 9.0 0.05 3.5
High 183 3.40 2.72 12.2 11.4 0.09 6.1
005 Medium 50 137 2.88 2.18 11.4 10.6 0.08 4.4
Low 102 2.22 1.70 10.7 10.3 0.06 2.8
High 235 3.84 3.15 13.4 12.2 0.10 5.9
006 Medium 50 185 3.35 2.62 12.8 11.6 0.09 4.6
Low 139 2 69
2.69 2 08
2.08 12 2
12.2 11 2
11.2 0 07
0.07 31
3.1
High 328 5.64 4.70 12.7 11.9 0.15 12.9
008 Medium 50 230 4.61 3.57 11.7 10.9 0.12 8.8
Low 148 3.18 2.48 10.7 10.4 0.09 4.2
High 360 5.99 4.91 13.3 12.1 0.16 15.8
010 Medium 50 269 5.03 3.90 12.5 11.4 0.14 11.1
Low 178 3.55 2.71 11.9 11.0 0.10 5.6
High 471 7.22 5.82 14.3 12.6 0.19 9.5
012 Medium 50 393 6.51 5.05 13.9 12.1 0.17 7.7
Low 299 5.38 4.06 13.3 11.6 0.14 5.3
High 510 8.27 6.57 13.9 12.3 0.22 13.7
014 Medium 50 432 7.56 5.77 13.5 11.8 0.20 11.5
Low 346 6.40 4.82 13.0 11.5 0.17 8.2
NOTE: Air Conditions: EDB/EWB 24.4/17.2°C Water Conditions: EWT/LWT 5.5/14.4˚C ∆T: 8.9˚C

- - For other design conditions, please apply the selection program to finalize your applications - -

22
PERFORMANCE RATING (cont’)

42CGT Cabinet Model (4-Rows)


Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42CGT Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 143 3.34 2.43 12.8 12.6 0.14 12.7
003 Medium 0 137 3.25 2.36 12.7 12.5 0.14 12.1
Low 116 2.91 2.07 12.1 12.05 0.12 9.8
Hi h
High 188 4 64
4.64 3 28
3.28 12 5
12.5 12 2
12.2 0 20
0.20 22 6
22.6
004 Medium 0 163 4.22 2.94 12.0 11.8 0.18 18.3
Low 133 3.75 2.51 11.3 11.0 0.16 12.3
High 225 5.64 3.97 12.3 12.1 0.24 46.9
005 Medium 0 183 4.95 3.39 11.6 11.4 0.21 36.1
Low 144 4.35 2.82 10.8 10.3 0.19 26.9
High 262 5.91 4.33 13.2 12.9 0.25 8.8
006 Medium 0 203 5.05 3.55 12.4 12.1 0.22 6.6
Low 156 4.26 2.88 11.6 11.3 0.18 4.7
High 340 8.38 5.94 12.4 12.2 0.36 21.6
008 Medium 0 279 7.42 5.09 11.8 11.5 0.32 16.9
Low 209 6.19 4.07 10.8 10.5 0.26 11.8
High 453 11.47 7.96 12.4 12.0 0.49 47.3
010 Medium 0 378 10.20 6.94 11.7 11.4 0.44 37.4
Low 302 9.01 5.82 10.9 10.4 0.38 29.1
High 523 13.04 9.15 12.4 12.1 0.56 48.1
012 Medium 0 448 11.81 8.13 11.9 11.6 0.50 41.5
Low 397 11.04 7.39 11.5 11.1 0.47 34.4
NOTE: Air Conditions: EDB/EWB 26.7/19.4°C * Water Conditions: EWT/LWT 7.2/12.8˚C ∆T: 5.6˚C
* As per AHRI 440 Standard Cooling Rating 80.0°F (26.7ºC) dry bulb, 67.0ºF(19.4ºC) wet-bulb and entering water temp 45ºF (7.2ºC).

42CGD Cabinet Model (4-Rows) - District Cooling Application


Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42CGD Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 143 2.28 2.02 12.9 12.4 0.06 7.6
003 Medium 0 137 2.22 1.96 12.8 12.3 0.06 7.3
Low 116 1.99 1.72 12.3 11.9 0.05 5.8
High 188 3.12 2.72 12.6 12.1 0.08 14.8
004 Medium 0 163 2.83 2.43 12.2 11.9 0.08 12.4
Low 133 2.51 2.08 11.6 11.3 0.07 9.6
g
High 225 3.89 3.33 12.3 11.9 0.10 27.5
005 Medium 0 183 3.41 2.85 11.7 11.4 0.09 18.4
Low 144 3.00 2.37 11.0 10.7 0.08 14.4
High 262 4.07 3.65 13.0 12.5 0.11 6.7
006 Medium 0 203 3.48 3.00 12.4 11.9 0.09 4.9
Low 156 2.93 2.43 11.7 11.4 0.08 3.5
High 340 5.92 5.05 12.3 11.8 0.16 23.5
008 Medium 0 279 5.25 4.33 11.7 11.4 0.14 16.6
Low 209 4.38 3.46 10.9 10.6 0.12 12.0
High 453 7.91 6.70 12.3 11.8 0.21 21.0
010 Medium 0 378 7.03 5.84 11.8 11.4 0.19 13.7
Low 302 6.21 4.90 11.1 10.7 0.17 11.0
High 523 8.36 7.33 13.0 12.3 0.22 14.4
012 Medium 0 448 7.57 6.52 12.5 12.0 0.20 12.0
Low 397 7.07 5.92 12.2 11.7 0.19 10.4
NOTE: Air Conditions: EDB/EWB 24.4/17.2°C Water Conditions: EWT/LWT 5.5/14.4˚C ∆T: 8.9˚C

- - For other design conditions, please apply the selection program to finalize your applications - -

23
PERFORMANCE RATING (cont’)

42DC Furred-in Cabinet Model (4-Rows)


Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42DC Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 313 6.57 4.69 14.5 13.4 0.28 25.6
006 Medium 50 262 5.85 4.10 13.9 13.0 0.25 20.9
Low 205 5.05 3.40 13.2 12.2 0.22 15.6
High 361 7.88 5.62 14.0 13.1 0.34 33.3
008 Medium 50 282 6 76
6.76 4 65
4.65 13 2
13.2 12 4
12.4 0 29
0.29 25 0
25.0
Low 200 5.39 3.55 12.2 11.4 0.23 16.3
High 512 9.94 7.39 14.9 13.9 0.42 52.7
010 Medium 50 441 9.03 6.61 14.4 13.6 0.40 44.2
Low 327 7.54 5.25 13.6 12.7 0.32 31.8
High 572 12.39 9.14 13.7 13.2 0.53 85.7
012 Medium 50 495 11.28 8.18 13.2 12.8 0.48 72.9
Low 397 9.88 6.89 12.5 12.1 0.42 58.1
Hi h
High 755 14 10
14.10 10 68
10.68 15 1
15.1 14 1
14.1 0 60
0.60 82 7
82.7
014 Medium 50 605 12.23 9.06 14.5 13.7 0.52 63.7
Low 550 11.51 8.43 14.2 13.4 0.49 57.9
High 858 17.71 13.21 14.1 13.5 0.76 114.6
016 Medium 50 767 16.51 12.17 13.7 13.2 0.70 100.3
Low 688 15.36 11.20 13.4 13.0 0.66 88.8
High 937 19.03 13.77 14.7 13.6 0.81 96.6
018 Medium 50 875 18.23 13.10 14.5 13.5 0.78 89.7
Low 692 15.65 10.96 13.8 12.9 0.67 68.9
High 970 20.43 14.47 14.5 13.4 0.87 117.6
020 Medium 50 890 19.32 13.56 14.3 13.2 0.83 105.4
Low 693 16.55 11.19 13.5 12.5 0.71 80.4
NOTE: Air Conditions: EDB/EWB 26.7/19.4°C * Water Conditions: EWT/LWT 7.2/12.8˚C ∆T: 5.6˚C
* As per AHRI 440 Standard Cooling Rating 80.0°F (26.7ºC) dry bulb, 67.0ºF(19.4ºC) wet-bulb and entering water temp 45ºF (7.2ºC).

42DCD Furred
Furred-in
in Cabinet Model (4
(4-Rows)
Rows) – District Cooling Applications
Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42DCD Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 313 4.89 4.14 13.6 12.5 0.13 26.8
006 Medium 50 262 4.35 3.62 13.1 12.1 0.12 21.5
Low 205 3.76 3.01 12.4 11.5 0.10 16.0
High 361 6.68 5.08 12.9 11.5 0.18 55.2
008 Medium 50 282 5.73 4.20 12.2 10.9 0.15 43.9
L
Low 200 4 57
4.57 3 20
3.20 11 3
11.3 10 0
10.0 0 12
0.12 28 0
28.0
High 512 8.02 6.94 13.3 12.4 0.22 53.5
010 Medium 50 441 7.29 6.21 12.9 12.1 0.20 45.6
Low 327 6.09 4.93 12.1 11.4 0.16 33.4
High 572 9.50 8.05 12.9 12.1 0.26 47.4
012 Medium 50 495 8.64 7.21 12.5 11.8 0.23 39.1
Low 396 7.58 6.07 11.9 11.3 0.20 32.2
High 755 11.20 9.87 13.7 12.7 0.30 41.7
014 Medium 50 605 9.72 8.37 13.1 12.3 0.26 32.8
Low 550 9.14 7.79 12.8 12.1 0.25 29.2
High 858 14.26 12.06 12.9 12.1 0.38 55.1
016 Medium 50 767 13.29 11.11 12.6 11.9 0.36 48.6
Low 687 12.37 10.22 12.3 11.7 0.33 42.7
High 937 15.15 12.65 13.4 12.3 0.41 62.6
018 Medium 50 875 14.51 12.03 13.2 12.1 0.39 59.1
Low 692 12.46 10.07 12.5 11.6 0.33 44.6
High 970 15.76 13.23 13.3 12.2 0.42 55.5
020 Medium 50 890 14.90 12.40 13.0 12.1 0.40 51.6
Low 693 12.77 10.23 12.3 11.5 0.34 38.8
NOTE: Air Conditions: EDB/EWB 24.4/17.2°C Water Conditions: EWT/LWT 5.5/14.4˚C ∆T: 8.9˚C

- - For other design conditions, please apply the selection program to finalize your applications - -
24
PERFORMANCE RATING (cont’)

42DE Ceiling Model (4


(4-Rows)
Rows)
Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42DE Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 313 5.87 4.68 14.5 14.1 0.25 14.2
006 Medium 50 246 5.03 3.91 13.7 13.6 0.22 10.5
Low 185 4.27 3.13 12.9 12.7 0.18 7.6
High 362 7.85 5.91 13.4 13.2 0.33 23.9
008 Medium 50 275 6 62
6.62 4 79
4.79 12 5
12.5 12 4
12.4 0 28
0.28 17 8
17.8
Low 197 5.28 3.67 11.5 11.5 0.23 11.6
High 470 9.78 7.40 13.9 13.5 0.42 30.1
010 Medium 50 401 8.81 6.55 13.4 13.1 0.38 24.5
Low 277 7.12 4.92 12.2 11.9 0.30 17.0
High 613 12.03 9.30 14.3 13.8 0.51 38.7
012 Medium 50 500 10.56 7.99 13.7 13.4 0.45 30.6
Low 352 8.64 6.10 12.6 12.3 0.37 21.7
High 770 15 23
15.23 11 71
11.71 14 3
14.3 13 8
13.8 0 65
0.65 34 9
34.9
014 Medium 50 618 13.23 9.94 13.6 13.3 0.57 27.5
Low 554 12.32 9.15 13.2 13.0 0.53 24.5
High 851 17.03 13.04 14.2 13.7 0.73 46.8
016 Medium 50 751 15.75 11.91 13.8 13.4 0.67 40.7
Low 676 14.69 10.98 13.4 13.2 0.63 36.3
High 961 19.62 14.84 14.1 13.6 0.84 29.7
018 Medium 50 848 18.16 13.55 13.7 13.3 0.78 25.8
L
Low 679 15 72
15.72 11 45
11.45 12 9
12.9 12 7
12.7 0 67
0.67 20 0
20.0
High 966 20.51 15.35 13.7 13.3 0.88 33.5
020 Medium 50 873 19.19 14.21 13.4 13.1 0.82 30.0
Low 681 16.49 11.73 12.6 12.4 0.70 22.8
NOTE: Air Conditions: EDB/EWB 26.7/19.4°C * Water Conditions: EWT/LWT 7.2/12.8˚C ∆T: 5.6˚C
* As per AHRI 440 Standard Cooling Rating 80.0°F (26.7ºC) dry bulb, 67.0ºF(19.4ºC) wet-bulb and entering water temp 45ºF (7.2ºC).

42DED Ceiling Model (4


(4-Rows)
Rows) – District Cooling Applications
Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42DED Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 313 4.86 4.36 13.0 12.5 0.13 15.1
006 Medium 50 246 4.16 3.64 12.3 12.0 0.11 11.1
Low 185 3.53 2.92 11.5 11.3 0.09 8.1
High 362 6.39 5.45 12.1 11.8 0.17 30.1
008 Medium 50 275 5.39 4.41 11.3 11.1 0.15 22.5
Low 197 4.30 3.38 10.4 10.3 0.12 14.7
High 470 7.86 6.81 12.6 12.1 0.21 50.2
010 Medium 50 401 7.08 6.03 12.1 11.8 0.19 41.9
Low 277 5.72 4.53 11.1 10.7 0.15 28.4
High 613 9.33 8.36 13.3 12.6 0.25 18.7
012 Medium 50 500 8.18 7.18 12.7 12.2 0.22 15.1
Low 352 6.69 5.48 11.7 11.3 0.18 10.0
High 770 11.85 10.56 13.2 12.5 0.32 30.1
014 Medium 50 618 10.29 8.97 12.6 12.1 0.28 23.5
Low 554 9.58 8.25 12.2 11.9 0.26 20.9
High 851 13.60 11.93 13.0 12.3 0.37 42.6
016 Medium 50 751 12.58 10.89 12.6 12.1 0.34 36.2
Low 676 11.73 10.05 12.3 11.9 0.32 32.5
High 961 14.83 12.88 13.4 12.5 0.40 53.7
018 Medium 50 848 13.72 11.77 13.1 12.3 0.37 46.5
Low 679 11.87 9.94 12.4 11.8 0.32 36.2
High 966 15.05 13.42 13.1 12.5 0.40 35.2
020 Medium 50 873 14.09 12.43 12.8 12.3 0.38 31.2
Low 681 12.10 10.26 12.1 11.7 0.32 23.4
NOTE: Air Conditions: EDB/EWB 24.4/17.2°C Water Conditions: EWT/LWT 5.5/14.4˚C ∆T: 8.9˚C

- - For other design conditions, please apply the selection program to finalize your applications - -
25
PERFORMANCE RATING (cont’)

42DF Exposed Ceiling Cabinet Model (4-Rows)


Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42DF Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 248 5.07 3.94 13.8 13.6 0.22 10.6
006 Medium 0 224 4.75 3.64 13.4 13.3 0.20 9.4
Low 187 4.29 3.16 12.9 12.8 0.18 7.7
High 317 7.20 5.35 12.9 12.7 0.31 20.9
008 M di
Medium 0 269 6 54
6.54 4 70
4.70 12 4
12.4 12 3
12.3 0 28
0.28 17 5
17.5
Low 215 5.70 3.95 11.7 11.5 0.24 13.5
High 402 8.82 6.56 13.4 13.1 0.38 24.6
010 Medium 0 314 7.65 5.41 12.6 12.3 0.33 19.3
Low 235 6.16 4.29 11.8 11.6 0.26 13.3
High 505 10.62 8.04 13.7 13.4 0.45 31.3
012 Medium 0 430 9.62 7.11 13.2 12.9 0.41 25.8
Low 381 9.00 6.47 12.8 12.5 0.38 23.3
High 578 12.67 9.45 13.4 13.1 0.54 25.7
014 Medium 0 491 11.47 8.33 12.8 12.6 0.49 21.0
Low 432 10.70 7.54 12.4 12.2 0.46 18.9
High 662 14.49 10.81 13.4 13.1 0.62 35.0
016 Medium 0 530 12.70 9.09 12.7 12.4 0.54 28.3
Low 452 11.66 8.05 12.4 11.8 0.50 23.9
High 801 17.48 12.97 13.5 13.1 0.75 24.2
018 Medium 0 681 15.74 11.47 12.9 12.7 0.67 20.2
Low 538 13.83 9.54 12.2 11.8 0.59 16.0
High 901 19.59 14.56 13.5 13.2 0.84 30.8
020 Medium 0 761 17.58 12.82 13.0 12.7 0.75 25.6
Low 596 15.36 10.59 12.2 11.8 0.66 20.1
NOTE: Air Conditions: EDB/EWB 26.7/19.4°C * Water Conditions: EWT/LWT 7.2/12.8˚C ∆T: 5.6˚C
* As per AHRI 440 Standard Cooling Rating 80.0°F (26.7ºC) dry bulb, 67.0ºF(19.4ºC) wet-bulb and entering water temp 45ºF (7.2ºC).

42DFD Exposed Ceiling Cabinet Model (4


(4-Rows)
Rows) – District Cooling Applications
Model ESP Air Flow Capacity (kW) Air off FCU (°C) Water Flow Water Pressure
Speed
42DFD Pa (ℓ/s) Total Sensible DB WB (ℓ/s) (kPa)
High 248 4.19 3.65 12.4 12.3 0.11 11.2
006 Medium 0 224 3.93 3.38 12.1 11.8 0.11 9.9
Low 187 3.55 2.93 11.6 11.3 0.10 8.2
High 317 5.86 4.90 11.8 11.5 0.16 26.1
008 Medium 0 269 5.32 4.30 11.3 11.0 0.14 22.0
Low 215 4.64 3.62 10.7 10.4 0.12 17.2
High 402 7.09 6.01 12.2 11.8 0.19 41.9
010 Medium 0 314 6.15 4.96 11.5 11.1 0.17 32.4
Low 235 4.95 3.93 10.8 10.6 0.13 22.0
High 505 8.23 7.19 12.8 12.2 0.22 15.2
012 Medium 0 430 7.45 6.36 12.3 11.9 0.20 12.4
Low 381 6.97 5.78 12.0 11.5 0.19 10.9
High 578 9.86 8.48 12.4 12.0 0.26 21.7
014 Medium 0 491 8.92 7.47 12.0 11.6 0.24 18.3
Low 432 8.32 6.77 11.6 11.2 0.22 16.6
High 662 11.57 9.84 12.3 11.8 0.31 31.4
016 Medium 0 530 10.14 8.28 11.6 11.2 0.27 25.2
Low 452 9.31 7.33 11.2 10.7 0.25 21.8
High 801 13.21 11.20 13.0 12.2 0.36 43.5
018 Medium 0 681 11.89 9.91 12.5 11.8 0.32 36.3
Low 538 10.45 8.24 11.9 11.2 0.28 28.6
High 901 14.38 12.66 12.9 12.3 0.39 31.7
020 Medium 0 761 12.90 11.15 12.4 12.0 0.35 26.4
Low 596 11.27 9.21 11.8 11.3 0.30 20.3
NOTE: Air Conditions: EDB/EWB 24.4/17.2°C Water Conditions: EWT/LWT 5.5/14.4˚C ∆T: 8.9˚C

- - For other design conditions, please apply the selection program to finalize your applications - -
26
ELECTRICAL DATA (cont’)

42C MOTOR DATA


Nominal Power
Unit Power Supply Fan Fan Speed Power Output Input Running
Model Size (V-Ph-Hz) Speed (rpm) (W) (W) Amps Remarks
Hi 1,320 61 0.27
003 Med 1,190 32 49 0.23
Low 1 080
1,080 40 0 19
0.19
Hi 1,320 82 0.36
004 Med 1,190 45 70 0.32
Low 1,080 61 0.29
Hi 1,320 97 0.42
005 Med 1,190 70 82 0.37
Low 1,080 72 0.33
Hi 1 320
1,320 114 0 50
0.50
006 Med 1,190 72 93 0.42 * Total motor amps and watts shown for
42CET Low 1,080 84 0.38 units with 2 motors (size 008 to 012).
220/240-1-50
42CED Hi 1,320 163 0.71 ** Total motor amps and watts shown for
008 * Med 1,190 55 (x2) 135 0.61 units with 3 motors (size 014).
Low 1,080 114 0.53
Hi 1,320 189 0.83
010 * Med 1 190
1,190 70 (x2) 154 0 68
0.68
Low 1,080 129 0.46
Hi 1,320 261 1.20
012 * Med 1,190 72 (x2) 219 0.96
Low 1,080 190 0.84
Hi 1,320 297 1.32
014 ** Med 1,190 70 (x3) 262 1.14
Low 1 080
1,080 235 1 04
1.04
Hi 1,320 72 0.32
003 Med 1,190 35 50 0.26
Low 1,080 36 0.20
Hi 1,320 81 0.36
004 Med 1,190 48 73 0.34
Low 1,080 64 0.30
Hi 1,320
,3 0 992 00.41
005 Med 1,190 68 81 0.37
Low 1,080 77 0.35 * Total motor amps and watts shown for
Hi 1,320 114 0.51 units with 2 motors (size 008 to 010).
42CGT ** Total motor amps and watts shown for
006 220~240-1-50 Med 1,190 75 95 0.45
42CGD units with 3 motors (size 012).
Low 1,080 90 0.43
Hi 1,320 160 0.71
008 * Med 1,190
, 58 ((x2)) 136 0.61
Low 1,080 113 0.53
Hi 1,320 239 1.05
010 * Med 1,190 75 (x2) 208 0.94
Low 1,080 191 0.88
Hi 1,320 333 1.57
012 ** Med 1,190 78 (x3) 248 1.09
Low 1,080 228 0.99
Note: Motor nameplate amps may vary.

27
ELECTRICAL DATA (cont’)

42D MOTOR DATA


Nominal Power
Unit Power Supply Fan Fan Speed Power Output Input Running
Model Size (V / Ph / Hz) Speed (rpm) (W) (W) Amps Remarks
Hi 1,000 228 1.13
006 Med 870 120 142 0.68
L
Low 750 106 0 52
0.52
Hi 1,000 247 1.21
008 Med 870 120 157 0.75
Low 750 115 0.57
Hi 1,000 446 2.02
010 Med 870 200 363 1.65
Low 750 248 1.14
Hi 1 000
1,000 448 2 27
2.27
012 * Med 870 120 (x2) 278 1.33
* Total motor amps and watts shown for
42DC/DCD Low 750 214 1.04
220~240/1/50 units with 2 motors (size 012).
42DE/DED Hi 1,000 639 2.96
014 Med 870 300 467 2.14
Low 750 410 1.88
Hi 1,000 724 3.29
016 Med 870 450 610 2 77
2.77
Low 750 517 2.36
Hi 1,000 806 3.68
018 Med 870 450 721 3.29
Low 750 517 2.35
Hi 1,000 810 3.69
020 Med 870 450 720 3.27
Low 750 520 2 36
2.36
Hi 1,000 162 0.77
006 Med 870 80 123 0.57
Low 750 91 0.42
Hi 1,000 168 0.78
008 Med 870 80 121 0.56
Low 750 90 0.42
Hi 865 250 1 22
1.22
010 Med 750 120 172 0.84
Low 640 127 0.65
Hi 865 313 1.43
012 * Med 750 80 (x2) 230 1.04
Low 640 178 0.82 * Total motor amps and watts shown for
42DF/DFD 220~240/1/50 Hi 865 312 1.43 units with 2 motors (size 012 to 020).
014 * Med 750 80 (x2) 231 1.05
Low 640 177 0.82
Hi 865 380 1.82
016 * Med 750 120 (x2) 326 1.60
Low 640 214 1.13
Hi 865 475 2.38
018 * Med 750 120 (x2) 326 1.63
Low 640 214 11.12
12
Hi 865 912 4.30
020 * Med 750 200 (x2) 461 2.26
Low 640 288 1.44
Note: Motor nameplate amps may vary.

28
WIRING DIAGRAM

42CET/CED & CGT/CGD Series Wiring Diagram (AC Motor)

OFF L M H TB
(H) RED H
1
(M) BLUE M
2 FM cap
B (L) WHITE L
3
(C)
4 CDM
YEL H
SS 5
M FM cap
6
L

CDM

POWER H
M FM cap
L
FM MOTOR
SS SWITCH CDM
TB TERMINAL BLOCK
cap CAPACITOR

NOTE: 1. Caution – Disconnect ppower before servicing.


g
2. Use 14 AWG, 75˚C MIN, copper conductor.
3. Motor(s) thermally protected.
4. Provide disconnect means and over current protection as required.
5. 42CET/CGT 003 to 006 are single motor; 42CET008 to 012 are double motors & 014 is three fan motors.
Whereas 42CGT008 to 010 are double motor & 012 is three fan motors.
6. Snap apart carefully at hingle to separate cover from the control box.

42CET/CED Series Wiring Diagram (EC Motor)

TB
L BLUE
1
N GRAY
POWER 2
E GREEN/YELLOW
3
WHITE WHITE PWM1 L
4
BLACK BLACK FG1 FM with N
5 Driver 1
E
RED RED COM
6
L
CONTROLLER WHITE
N WHITE PWM2 L
7
BLACK BLACK FG2 FM with N
8
Driver 2 E
RED RED COM
9

LEGEND:
FIELD WIRING
FACTORY WIRING IF REQUIRED FM MOTOR
FACTORY WIRING TB TERMINAL BLOCK

NOTE: 1. Caution – Disconnect power before servicing.


2. 42CET/CED 002~006 – single motor; 008~012 – double motors.
3. Single motor use 6 pole terminal block, double motors use 9 pole terminal block.
6. Snap apart carefully at hingle to separate cover from the control box.

29
WIRING DIAGRAM

42DC/DCD/DE/DED 006~012 and 42DF/DFD Wiring Diagram (AC Motor)

BLK
BRN
BLU

RED FAN
MOTOR 2 CAPACITOR
YEL OR WHT

BRN

TERMINAL
OFF L M H BLOCK
HIGH BLK
H
1 BRN

M MEDIUM BLU
2 FAN
B L LOW RED
MOTOR 1 CAPACITOR
3
C BRN
COMMON YEL OR WHT
4
3 SPEED SWITCH

L1 EQUIP. GND.
L2 OR N
GROUND
42DC UNIT WIRING

POWER SUPPLY LEGEND:


SEE NAMWPLATE FOR FIELD WIRING
CORRECT VOLTAGE FACTORY WIRING IF REQUIRED
FACTORY WIRING

NOTE: 1. Caution – disconnect power before servicing.


2. Use 14 AWG, 75˚C MIN, copper conductor.
3. Motor(s) thermally protected.
4. Provide disconnect means & over current protection as required.
5. Unit 42DC-012 has 2 fan motors, rest are single motor.

42DC/DCD & 42DE/DED 014~020 Wiring Diagram (AC Motor)


FAN MOTOR SPEED USED / COLOR
MODEL
HI MED LOW UNUSED
42DC/DCD014 & 42DE/DED014 RED BROWN ORANGE YELLOW
42DC/DCD016 & 42DE/DED016 YELLOW BROWN ORANGE RED
42DC/DCD018 & 42DE/DED018 RED YELLOW ORANGE BROWN
42DC/DCD020 & 42DE/DED020 RED YELLOW ORANGE BROWN

NOTE: 1. Caution – disconnect power before servicing.


2. Use 14 AWG, 75˚C MIN, copper conductor.
3. Motor(s) thermally protected.
4. Provide disconnect means & over current protection as required.

M RED
OFF L H TB BLK
HIGH
TO TABLE

H YEL
REFER

1
M MEDIUM BRN
2 CAP
B L LOW ORA
3
C COMMON BLU BLK
4

3 SPEED SWITCH EQUIP. GND.

LEGEND:
FIELD WIRING
FACTORY WIRING IF REQUIRED
FACTORY WIRING

30
WIRING DIAGRAM

42DC/DCD006~020 Wiring Diagram (EC Motor)

GREEN/YELLOW E
GROUND 1
L1 BLUE L
2
L2 or N GREY N
3
WHT WHT PWM1
4
BLK BLK FG1 DRIVER FAN
5 1 MTR 1
CONTROLLER

RED RED COM


L 6
WHT WHT PWM2
N 7
BLK BLK FG2 DRIVER FAN
8
2 MTR 2
RED RED COM
9

TB

LEGEND:
FIELD WIRING
FACTORY WIRING IF REQUIRED
FACTORY WIRING

NOTE: 1. Caution – disconnect power before servicing, wait for at least 20 sec to allow current completely drain off from driver.
2. Use 14 AWG, 75˚C MIN, copper conductor.
3. Motor(s) thermally protected.
4. Provide disconnect means & over-current protection as required.
5. All models use 6 pole terminal block except 42DC-012 with 2 fan motors uses 9 pole terminal block.
6. Use cable wire “UL2464”specification to ensure transmission reliability for motor to FCU controller.

31
GUIDE SPECIFICATIONS

HVAC Guide Specifications 2.5 42DE/DED Horizontal Painted Cabinet unit for
Size range: 300 to 2000 Nominal Cfm concealed installation
Unit shall be constructed of galvanized steel with
Part 1 – GENERAL removable panels for access to internal components.
Units have 12.7mm PU insulation 20kg/m³ density on
1.1 System Description chassis and plenum box and 6.0mm PE insulation
Horizontal room fan coil unit with furred-in,
Horizontal, furred in above 28.6kg/m³
g densityy on the drain p pan. Filter track with
ceiling for ducting, or with cabinet for exposed ceiling one-in permanent filter, one-in supply collar and 64mm
installations. return air collar on rear of unit for duct connection.

1.2 Quality Assurance 2.6 42DF/DFD Horizontal Cabinet Unit for Exposed
Unit shall be tested in accordance with ARI Standard Installation
440. Each coil shall be factory tested for leakage at Unit shall be constructed of steel with morning mist re-
400 psig air pressure with coil submerged in water. coatable baked enamel finish. Cabinet shall be lined
Factoryy is ISO-9001 certified. with 12.7mm PU insulation 20kg/m³ g densityy on chassis
and plenum box and 6.0mm PE insulation 28.6kg/m³
1.3 Delivery storage and handling
density on the drain pan and have removable bottom
Each unit shall be individually packaged from point of
access panel. Unit shall include hinged bar type return
manufacture. Unit shall be handled and stored in
air grille on rear of unit with one-in permanent filter and
accordance with the manufacturer’s instructions.
integral double deflection supply grille.
Part 2 - PRODUCTS 2.7 Fan
Direct driven, double width fan wheels with forward
Equipment curved d blades
bl d shall
h ll be
b statically
t ti ll andd dynamically
d i ll
2.1 General balanced. Scrolls shall be constructed of galvanized
Factory assembled, horizontal, blow-thru type fan coil steel. Fan wheels shall be constructed of galvanized
for furred-in, exposed ceiling or ducted installations. steel.
Unit shall be complete with water coil(s), fan(s), 2.8 Coils
motor(s), drain pan, filters and all required wiring, Galvanized drain pan covers entire length & width of
collars for ducted units. Unit insulation are UL94 coil till the headers. Drain pan inside powder coated
compliance, whereas drain pan insulation are UL94 & and outside insulated.
NFPA-90A compliance.
2.2 42CET, CED Furred-in Units 42CET/CED & DC/DCD models
Base 42CET, CED unit with factory installed plenum Standard base unit shall be equipped with a 3-row or
section and cleanable filter as shown on equipment 4-row coil for installation in a 2-pipe system. Coils
drawings. The plenum shall be rear air return. Shall shall have 7mm copper tubes, aluminium fins bonded
enclose the fan/motor assemblies, and shall be lined to the tubes by mechanical expansion. Each coil shall
with 10mm thick PU insulation 20kg/m³ density and have a manual air vent and threaded or sweat
6 0mm PE insulation 28.6kg/m
6.0mm 28 6kg/m³ density on the drain connections
co ect o s field
ed p piping
p g ((refer
e e to Technical
ec ca Data).
ata)
pan. Unit shall have a removable panel to provide Working pressure 1.72 MPa, 0.105mm fin thickness
access to fan/motor assemblies and unit identification and 0.24mm tube wall thickness.
label.
42CGT/CGD, DE/DED & DF/DFD models
2.3 42CGT/CGD Decorative Ceiling Fan Coil Unit Standard base unit shall be equipped with 4-row coil
Unit with stamped discharge grille, removable bottom for installation in a 2-pipe system. Coils shall have
access panel with stamped return air grille, filter track 9.5mm copper tubes, aluminium fins bonded to the
and filter. The panel shall be fastened with slotted tubes byy mechanical expansion.
p Each coil shall have
head, positive-locking quarter-turn fasteners. a manual air vent and threaded or sweat connections
Units have 12.7mm PU insulation on chassis and field piping (refer to Technical Data). Working
10mm PU insulation on coil top panel with 20kg/m³, pressure 1.72 MPa, 0.105mm fin thickness and
and 6.0mm PE insulation 28.6kg/m³ density on the 0.28mm tube wall thickness.
drain pan.
2.4 42DC/DCD Horizontal Base Unit with Plenum for 2.9 Operating Characteristics
Concealed Installation A one coil unit installed in a 2-pipe system shall be
Unit have a factory installed,
installed galvanized steel plenum capable
bl off providing
idi cooling
li as determined
d t i d byb the
th
section and one-in permanent filter. The plenum shall operating mode of the central water supply system.
be rear return, lined with 12.7mm PU insulation
20kg/m³ density and plenum box and 6.0mm PE
insulation 28.6kg/m³ density on the drain pan, and
include a removable panel to provide access to the
fan/motor assembly.
32
GUIDE SPECIFICATIONS

3.0 Electrical Requirements


Standard unit shall operate on 220/240v, single phase,
50Hz electric power. All internal wiring shall be in
flexible conduit.
3.1 Motor(s)
Fan motors shall be 3-speed, 220/240v, single phase,
50H permanentt split
50Hz, lit capacitor
it type,
t with
ith ball
b ll type
t
bearings and oversized oil reservoirs to ensure
lubrication.
The fan motor(s) shall be equipped with integral
automatic temperature reset for motor protection.
Motor End Closure
Model Unit Size Insulation Class Type
42C series All B Open Drip Proof
006~012 E
42DC/DCD
014~020 F
006~012 E Open
42DE/DED
014~020 F
42DF/DFD All E

* EC Motor is available as option (42CET/CED &


42DC/DCD) f to
42DC/DCD),refer t factory
f t f EC motor
for t data.
d t

LT101
Controller

3 2 Filter
3.2
Permanently washable aluminium filters with 21mm
thick and 70% gravimetric efficiency as per European
Union EN779 class.

Arrestance or Dust US European Union


Spot Efficiency Ashrae 52.2 EN779 Class
AFI 65% - 70% MERV 2 G2 65%≤Am≤85%

* Refer to factory for synthetic fibre filter option.

33
Carrier International Sdn Bhd, Malaysia
Manufacturer reserves the right to discontinue, or change at anytime, specifications or designs without notice and without incurring obligations.
42CD-E13-7PD
INSTALLATION, START-UP AND
Carrier
International SERVICE INSTRUCTIONS
42C
Sdn. Bhd.
Malaysia FAN COIL AIR CONDITIONERS
M k Piping
Make Pi i C
Connections
ti - Refer
R f tot Table
T bl 1 for
f piping
i i
CONTENTS:
connection physical dimensions.
INSTALLATION 1
DRAIN CONNECTIONS - Install drain line in accordance
PHYSICAL DATA 2 with all applicable codes. Slope drain away from unit.
Insulate the drain line to prevent sweating.
POWER ON 2
START-UP 3 WATER SUPPLY/RETURN CONNETIONS - Install
piping in accordance with all applicable codes. Position
SERVICE 3 valves over the drain pan. Be sure valves are in proper
operating position and are easily accessible for adjustment.
If coil and valve package connections will be made with a
INSTALLATION
solder joint, care should be taken to ensure that
components in the valve package are not subjected to high
Unpack and Inspect Units - Remove shipping wraps temperatures which may damage seals or other materials.
from all units. Check the shipment against shipping order. if Many 2-position electric control valves are provided with a
shipment is damaged or incomplete, file claim with manual operating level. This level should be in the OPEN
transportation company and advise Carrier immediately. position during all soldering operations.
If coil connection is made with a union, the coil side of the
Protect Units Form Damage -To maintain warranty, union must be prevented from turning (it must be backed
protect units against adverse weather, theft or vandalism on up) during tightening. Do not over tighten! Over tightening
jobsite. will distort (egg shape) the union seal surface and destroy
the union.
Prepare Jobsite for Unit Installation - To save time
and to reduce the possibility of costly errors, set a complete Steam Connections - On units with steam heating coils, the
sample installation in a typical room at jobsite. Check all maximum steam pressure applied to the unit should never
critical dimensions such as pipe, wire and duct connection exceed 10 psig.
requirements. Refer to job drawings and product dimension
drawings as required. Instruct all trades in their part of the TEST AND INSULATE -When all joints are complete,
installation. perform hydrostatic test for leaks. Vent all coils at this time.
Check interior unit piping for signs of leakage from shipping
Identify and Prepare Units damage or mishandling. If leaks are found, notify a Carrier
Be sure power requirements match available power source. representative before initiating any repairs. Release
Refer to unit nameplate and wiring diagram. trapped air from system (refer to Make Final Preparations
section).
Place Unit in Position
1
1. Be sure unit is level or pitched towards drain to ensure
proper drainage and operation. Pitch of suspended unit
can change after coil is filled; recheck after filling coil. All water coils must be protected from freezing after
2. When installing ceiling units, use factory-provided initial filling with water. Even if system is drained, unit
mounting holes. Units are not balanced on mounting coils may still have enough water to cause damage
holes. Select suitable vibration isolators at installation. If when exposed to temperatures below freezing
used, adjust isolators so unit is uniformly suspended and
pitched. Following the hydrostatic test, insulate all piping to prevent
3. Models 42CE with bottom inlet may be installed in sweating.
noncombustible areas only.
only To ensure compliance with building codes, restore the
4. Protect units from damage caused by jobsite debris. Do structure’s original fire resistance rating by sealing all holes
not allow foreign material to fall into drain pan. Prevent with materials carrying the same fire rating as the structure.
dust and debris from being deposited on motor or fan
wheels. Make Electrical Connections - Refer to unit serial plate
for required supply voltage, fan and heater amperage and
Table 1 – Physical Data required circuit ampacities. Refer to unit wiring diagram for
Dimension (inch) unit and field wiring.
COIL OUTLET,, INLET 5/8 OD The fan motor(s) should never be controlled by any wiring
or device other than the factory-supplied switch or
DRAIN CONNECTION 42C 7/8 OD thermostat/ switch combination unless prior factory
SUPPLY DUCT authorization is obtained. Fan motor(s) may be temporarily
1
Flange Connection wired for use during construction only with prior factory
approval and only in strict accordance with the instructions
issued at that time
42CGT/CGD
42CET/CED

All field wiring must be in accordance with governing codes POWER ON


and ordinances. Any modification of unit wiring without 1. Turn on unit power. Check fan and motor operation.
factory authorization will invalidate all factory warranties 2. Be sure drain line is clear and is properly and securely
and nullifyy anyy agency
g y listings.
g positioned. Pour water into drain to check operation.
p p
3. Vent all air from unit coil and related piping. If air vent
Make Duct Connections - Install all ductwork to and is manual, release air from system by turning air vent
from unit in accordance with all applicable codes. Duct screw 1 ½ turns counterclockwise with screwdriver.
construction must allow unit to operate within duct external When steady stream of water begins to escape, close
static pressure limits as shown on job submittals. Units valve. If air vent is automatic, trapped air will be vented
designed to operate with ductwork may be damaged if automatically. Vent releases air slowly, usually
operated without intended ductwork attached. dripping water into drain pan in the process. Make sure
Units provided with outside air should have some method all service valves are open and that motorized control
p
of low-temperature protection to p
p prevent coil freeze-up.
p valves,, if supplied,
pp , are set for automatic operation.
p
Insulate all ductwork as required, Use flexible connection to 4. Check all control valves in the system for proper
minimize duct-to-unit alignment problems and noise operation in accordance with valve manufacturer’s
transmission where specified. instructions.
Install ductwork, accessory grilles and plenums so that they 5. For units with factory-installed balancing valves, adjust
do not restrict access to filter. as follows:
Cut openings for supply and return air grilles, thermostats a. Butterfly valves - Turn valve gate by inserting
and switch plates where specified on job drawings. Be screwdriver into slot in valve top and rotating up to
careful not to cut wires, piping or structural supports. Use a 90 degree. Valve is fully open when slot is parallel
steel thermostat shield ring g to pprotect drywall
y from with valve body.
body When slot is perpendicular to
thermostat wiring where applicable. body, flow through valve is at minimum. Valve
Prevent dust and debris from settling in unit. If wall finish or does not seal against flow.
color is to be spray applied, cover all openings to prevent b. Ball valves with lever handles - Valve gate action
spray from entering unit. is similar to butterfly valves above except that
when handle is perpendicular to valve body, there
Make Final Preparations is no flow through valve. Ball valve may be used
POWER ON (open unit electrical disconnect) as shutoff valves.
1. Install thermostats and perform any other final wiring
as applicable.
applicable 6. Install filter in frame at front of coil. If field-supplied
pp
2. Clean dirt, dust and other construction debris from unit filters are used, be sure size is as specified in Table 2.
interior. Be sure to check fan wheel and housing.
Table 2 – Filter Data
3. Rotate fan wheel by hand to be sure it is free and does
not rub housing. Check that wing nuts securing fan Unit Size Nominal  Filter Size (in., 1‐in thick) *
assembly to fan deck are tight. CFM CET/CED CGT/CGD
003 300 7.5 x 23.3 10 x 37
004 400 7.5 x 28.0 10 x 37
005 500 7 5 x 31 2
7.5 x 31.2 10 X 37
10 X 37
006 600 7.5 x 39.1 10 x 40
008 800 7.5 x 48.5 10 x 53
010 1000 7.5 x 53.2 10 x 53
012 1200 7.5 x 62.7 10 x 63
014 1400 7.5 x 72.1 ‐
* Filter size if located in return air plenum.
2
START-UP Check Drain -Lock open and tag unit electrical disconnect.
Check drain pan, drain line and trap at start of each cooling
IMPORTANT: Do not start up or operate unit without filter. season. A standard type pipe cleaner for 3/4-in. ID pipe can
Be sure filter and unit interior are clean. be used to be sure pipe is clear of obstruction so that
condensate is carried away. Check the drain line at filter
Start-up procedures vary depending on time of year cleaning time during the cooling season. Be sure that debris
(summer or winter) and building characteristics (new g supply
has not fallen into unit through pp y air g
grille.
building/old building, occupied/unooccupied, etc.).
Start-up in the cooling mode requires that proper care be Fan Motor Bearings - Standard motors are permanently
given to avoid condensation problems. Condensation forms sealed and lubricated. No lubrication is required unless
on surfaces that are colder than the dew point of the special motors have been supplied or unusual operating
surrounding air. If a unit is started and is piped with low- conditions exist.
temperature chilled water in a hot, humid atmosphere,
condensation will form on many parts of the unit. In order to Clean Fan Wheel -Lock open and tag unit electrical
avoid excessive condensation, higher temperature water disconnect. For access to fan assembly, remove front or
should initially be used (approximately 65-70
65-70°F)
F). Also,
Also the bottom panel.
panel Fan assembly may be removed from its tracks
building should be as completely closed as possible and if unit has a long conduit lead. Use a stiff brush or vacuum to
outside air supply fans, and bathroom and kitchen exhaust remove dirt and debris from scroll. Wipe all fan surfaces with
fans should be off. a damp cloth.
As the building temperature drops, the chilled water
temperature can be gradually reduced until it reaches 50°F. Cleanable Air Filters -Lock open and tag unit electrical
At this point the outside air fans can be turned on. When disconnect. At the start of each cooling season and after
the chilled water temperature is reduced to its design point, month of operation (more or less depending on operating
the exhaust fans can be turned on. conditions) clean permanent filter.

SERVICES PERMANENT FILTER (FIBER TYPE)


Excessive Condensation on Unit -Excessive 1. Tap on solid surface to dislodge heavy particles.
condensation can be caused by running chilled water 2. Wash in hot water. If needed, use mild solution of
through a fan coil unit with the unit fan off. If fan cycling is commercial solvent such as sal soda or trisodium
used, a water flow control valve should be installed to shut phosphate.
off the water when fan stops. 3. Set filter on end so that water drains out through slots in
frame. Allow filter to dry thoroughly.
Other methods of control which avoid condensation
problems
bl are as follows:
f ll
1. Continuous fan operation with motorized chilled water
valve controlled by a thermostat.
2. Continuous fan operation with thermostat control to
switch fan from high to low speed (instead of off).

To Clean Coil
1. Be sure electrical disconnect is open, locked and
tagged while working on unit.
2 Remove return air grille access panel and brush
2.
between coil fins with stiff wire brush. Follow up by
cleaning with vacuum cleaner. If coil is cleaned with air
hose and nozzle, take care not to drive dirt and dust
into other components.
3. Install clean filter as described in the section Clean or
Replace Air Filters.

Carrier
International
Sdn. Bhd.
Malaysia

Carrier International Sdn. Bhd. (3385-T)


Lot 4, Jalan P/6, 43650 Bandar Baru Bangi,
Selangor, Malaysia.
Tel: 603-89258001 42C REV-2
Fax: 603-89253578 02 2012
Manufacturer reserves the right to discontinue,
or change at any time, specifications or designs
without notice and without incurring obligations.
INSTALLATION, START-UP AND
Carrier
International SERVICE INSTRUCTIONS
42D
Sdn. Bhd.
Malaysia FAN COIL AIR CONDITIONERS

CONTENTS:
INSTALLATION 1
PHYSICAL DATA 2
POWER ON 3
START-UP 3
SERVICE 3-4
Fig. 1 – Drain Line Details, Typical
INSTALLATION
Step 6 - Make Piping Connections
Step 1 - Unpack and Inspect Units DRAIN LINE - Install a trapped drain line in accordance with
Remove shipping
R hi i wraps from
f allll units.
it Check
Ch k the
th shipment
hi t all applicable codes.
codes Slope drain line away from unit.
unit Insulate
against shipping order. Check for concealed shipping drain line to prevent sweating. Drain connections are shown
damage. If shipment is damaged or incomplete, file claim in Fig. 1 and 2.
with transportation company and advise Carrier immediately.
WATER SUPPLY/RETURN CONNECTIONS - Maximum
Step 2 - Protect Units from Damage allowable entering hot water temperature is 190°F. Install
To maintain warranty, protect unit against adverse weather, piping in accordance with all applicable codes. See Table 1.
theft or vandalism at jobsite. Position valves over the drain pan. Be sure valves are in
proper operating position and are easily accessible for
adjustment.
Step 3 - Prepare Jobsite for Unit Installation
To save time and reduce the possibility of costly errors, set
If valves cannot be installed over drain pan, insulate valves
up a complete sample installation in a typical room at jobsite.
to prevent sweating.
Check all critical dimensions such as pipe, wire and duct
connection requirements. Refer to job drawings and product
If coil and valve package connections are to be made with a
dimension drawings as required. Instruct all trades in their
solder joint, care should be taken to ensure that no
part of the installation
components in the valve package are subjected to a
Step 4 - Identify and Prepare Units temperature high enough to damage seals or other
1. Be sure unit power requirements match available power materials. Many 2- position electric control valves have a
source. Refer to unit nameplate and wiring diagram. manual operating lever. This lever should be in the OPEN
2. Units are designed for chilled water or hot water (190°F position during all soldering operations.
maximum) only. Unit may be equipped with optional
electric heater. Be sure that the required control If coil connection is made with a union, the coil side of the
packages for the unit have been supplied. union must be prevented from twisting (i.e., it should be
3. Check all tags on unit to determine if shipping screws “backed
backed up up”)) during tightening.
tightening Do NOT over-tighten!
over tighten!
are to be removed. Remove screws as directed. Over-tightening distorts the union seal surface and destroys
the union.
Step 5 - Place Unit in Position
1. Be sure unit is level or pitched towards drain to ensure Steam Connections - On units with steam-heating coils,
proper drainage and operation. (see Fig. 1 and 2.) Pitch the maximum steam pressure applied to the unit should
of suspended unit can change after coil is filled; recheck never exceed 10 psig.
after filling coil.
Unit weight distribution is not uniform at mounting points. Test And Insulate - When Wh allll joints
j i t are completed,
l t d
Suspend unit at factory-provided holes (Fig. 2). If used, perform hydrostatic test for leaks. Vent all coils at this time.
select and adjust vibration isolators so that unit is Check interior unit piping for signs of leakage from shipping
uniformly suspended and pitched. damage or mishandling. If leaks are found, notify a Carrier
2. Models, with bottom inlet, may be installed in representative before initiating any repair. Release trapped
noncombustible return air spaces only. air from system (see Step 9-6).
3. Protect units from damage caused by jobsite debris. Do
not allow foreign material to fall in unit drain pan.
Prevent dust and debris from being deposited on motor All water coils must be protected from freezing after
or fan wheels. initial filling with water. Even if system is drained, unit
coils may still have enough water to cause damage
when exposed to temperatures below freezing
42DF/DFD
42DF 42DE/DED
42DC/DCD
LEGEND:
1 - Coil
2 - Drain, 7/8” O.D.
3 - Hanger Mounting Holes diameter, 7/8”
4 - Junction Box (or power K.O.)
5 - Supply Air Duct Collar, 1”
Note: 6 - Coil Outlet
42DE & DF are supplied complete with the casing and 7 - Coil Inlet
the legend for internal parts are as per 42DC diagram. 8 - Access Panel

42DC/DCD 42DE/DED, DF/DFD Units with aquastats furnished and installed at the factory
Unit may be shipped with the aquastats mounted on a coil
Inlet Outlet Inlet Outlet
Size stubout. If so, remove the aquastat before installing a valve
(in. OD) (in. OD) (in. OD) (in. OD) package.
p g When re-installing
g the aquastats,
q , consult the
006 7/8 7/8 factory piping diagram in the submittals for proper location. If
008 7/8 7/8 the valve package is field supplied, the aquastat must be
installed in a location where it will sense the water
010 7/8 7/8
temperature regardless of the position of the control valve. A
012 7/8 7/8 bleed bypass may be required to ensure proper aquastat
7/8 7/8
014 1 1/8 1 1/8 operation.
016 1 1/8 1 1/8
All field wiring
g should be done in accordance with g governing
g
018 1 1/8 1 1/8 codes and ordinances. Any modification of unit wiring without
020 1 1/8 1 1/8 factory authorization will void all factory warranties and will
nullify any agency listings.

Following the hydrostatic test, insulate all piping, controls Step 8 - Make Duct Connections
and valves to unit to prevent sweating. Install all ductwork to and from unit in accordance with all
applicable codes. Duct construction must allow unit to
To ensure compliance with building codes, restore the operate without duct external static pressure limits as shown
structure’s original fire resistance rating by sealing all holes on job submittals. Units designed to operate with ductwork
with material carrying the same fire rating as the structure. may be damaged if operated without the intended ductwork
attached. Units configured to bring in outside air should have
Step 7 - Make Electrical Connections some method of low temperature protection to prevent coil
See unit serial plate for required supply voltage, fan and freeze-up.
heater amperage, and required circuit ampacities. See unit
wiring diagram for unit wiring and field wiring. Insulate all ductwork as required. Use flexible connections to
minimizee duct
duct-to-unit
to u t aalignment
g e t p problems
ob e s a and
d noise
o se
The fan motor(s) should never be controlled by any wiring or transmission where specified.
device other than the factory-supplied switch or thermostat/
switch combination unless factory authorization has been Install ductwork, accessory grills and plenums so that they
obtained. Fan motor(s) may be wired for temporary use do not restrict access to filter. (See Fig. 2 and Table 2.)
during construction only if: (1) prior factory approval has
been obtained, and (2) wiring and operation are done in strict
accordance with the instructions issued by the factory.

2
Prevent dust and debris from setting in unit. If wall finish or START-UP
color is to be spray applied, cover all openings to prevent Start-up procedures vary depending upon the time of year
spray from entering unit. (summer or winter) and building characteristics (new building
or old building, occupied or unoccupied, etc.).
Table 2 - Filter Data (One-in. thick)
Start up in the cooling mode requires that proper care be
Start-up
Unit Size L x H (inch) given to avoid condensation problems. Condensation forms
Size 42DC/DCD 42DE/DED 42DF/DFD on surfaces that are colder than the dew point of the
surrounding air. If a unit is started and is fed low-temperature
006 14 x 21 14 x 13 ¾
chilled water in a hot, humid setting, condensation will form
008 14 x 26 14 x 19 ¾ on many parts of the unit. In order to avoid excessive
010 14 x 30 14 x 23 ¾ condensation, water of a higher temperature should be used
-approximately 65-70°F. Also, the building should be as
012 14 x 35 14 x 27 ¾ completely
p y enclosed as p possible and outside air supply
pp y fans
014 14 x 40 14 x 33 ¾ and bathroom and kitchen exhaust fans should be off.
016 14 x 45 14 x 37 ¾
As the building temperature drops, the chilled water
018 14 x 50 14 x 43 ¾ temperature can gradually be reduced until it reaches 50°F.
020 14 x 54 14 x 47 ¾ At this point, the outside air fans can be turned on. When the
chilled water temperature is reduced to its design point the
Note: Filter sizes for models 42DC/DCD and DF/DFD are exhaust fans can be turned on.
factory supplied cleanable filters.

Step 9 - Make Final Preparations


POWER OFF (open unit electrical disconnect).
SERVICE
Excessive Condensation on Fan Coil Unit Parts
Excessive condensation can be caused by running chilled
water through a fan coil unit with its fan off. Therefore, if fan
cycling control is used, a water flow control valve should be
Be sure electrical disconnect is open, locked and tagged installed to shut off the water when the fan stops.
when working on unit.
The following 2 practices will also help avoid condensation
1. Install thermostat and perform any other final wiring as problem:
applicable. 1. Continuous fan operation, with motorized chilled water
2. Clean dirt, dust and other construction debris from unit valve controlled by thermostat.
interior. Be sure to check fan wheel and housing. 2. Continuous fan operation, with thermostat control to
3. Rotate fan wheel by hand to be sure it is free and does switch fan from high to low speed (Instead of switching it
not rub housing. Check that nuts securing fan assembly off).
to fan deck are tight.
tight
To Clean Coil
POWER ON 1. Be sure electrical disconnect is open, locked and tagged
4. Turn on unit power. Check fan and motor operation. while working on unit.
5. Be sure drain line is clear and is properly and securely 2. Remove access panels, grilles or fan deck as required
positioned. Pour water into drain to check operation. and brush between coil fins with stiff wire brush. Follow
6. Vent all air from unit coil and related piping. If air vent is up by cleaning with vacuum cleaner. If coil is cleaned with
manual, release air from system by turning air vent air hose and nozzle, take care not to drive dirt and dust
screw 11/2 turns
t counterclockwise
t l k i with
ith screwdriver.
di i t other
into th components. t
When steady stream of water begins to escape, close 3. Install clean filter as described in Clean or Replace Air
valve. If air vent is automatic, trapped air will be vented Filters.
automatically. Vent releases air slowly, usually dripping
water into drain pan in the process. Check Drain -Lock open and tag unit electrical disconnect.
Check drain pan, drain line and trap at start of each cooling
Make sure all service valves are open and that season. A standard-type pipe cleaner for 7/8-in. ID pipe can
motorized control valves, if supplied, are set for be used to be sure pipe is clear of obstruction so that
automatic operation.
operation condensate is carried away. away Check drain line at filter
cleaning time during the cooling season. Be sure that debris
6. Check all control valves in the system for proper has not fallen into unit through supply air grille
operation in accordance with valve manufacturer’s
instructions. Remove Fan Assembly -Lock open and tag unit
7. Check that air filter of correct type and size is installed in electrical disconnect. For access to fan assembly, remove
unit filter rack. Also, see Service, Clean or Replace Air either side or front panel. If unit has an extra long fan motor
Filters. conduit lead, remove fan assembly from its tracks.
Otherwise disconnect motor leads at motor terminals.
Otherwise, terminals Then
Do not start-up or operate unit without filter. Be sure filter and
slide out fan assembly.
unit interior are clean
Fan Motor Bearings - Standard motors are permanently
lubricated and sealed. No lubrication is required unless
special motors have been provided or unusual operating
conditions exist.
3
Clean Fan -Lock open and tag unit electrical disconnect. WASHABLE FILTER - Replace filter with a good quality
Remove dirt and dust accumulation from fan wheel blades, filter of the same size shown in Table 2. Do not attempt to
fan housing and motor using a brush and vacuum cleaner. clean and reuse disposable filters.

Clean Electric Heater -Lock open and tag heater and unit
di
disconnects.
t Check
Ch k that
th t airflow
i fl th
through
h heater
h t elements
l t is
i PERMANENT FILTER (Fiber Type)
unobstructed. Clean heater elements with soft brush or 1. Tap on solid surface to dislodge heavy particles.
vacuum cleaner as necessary. 2. Wash in hot water. If needed, use mild solution of
commercial solvent such as sal soda or trisodium
Clean or Replace Air Filters -Lock open and tag unit phosphate.
electrical disconnect. At the start of each cooling season and 3. Set filter on end so that water drains out through slots in
after each month of operation (more or less depending on frame. Allow filter to dry thoroughly.
operating conditions) replace throwaway filter or clean 4. Recharge filter with Film-Cor or similar recharging oil.
permanent filter. Three ounces is sufficient for medium-size
medium size filter.
filter Oil may
be applied by insect spray gun. For easier spraying, the
To remove filter, remove unit front panel and slip filter oil can be warmed. If filter is dipped in recharging oil,
forward out of filter rack. remove it immediately and allow to drain through slots in
frame.
5. Replace filter in unit. Replace unit front panel. If another
type of filter is used, follow filter manufacturer’s
instruction.

Carrier
International
Sdn. Bhd.
Malaysia

Carrier International Sdn. Bhd. (3385-T)


Lot 4, Jalan P/6, 43650 Bandar Baru Bangi,
Selangor, Malaysia.
T l 603
Tel: 603-89258001
89258001
Fax: 603-89256589

42D Rev-2
04 2012
Manufacturer reserves the right to discontinue,
or change at any time, specifications or designs
without notice and without incurring obligations.