100% found this document useful (1 vote)
2K views3 pages

Thickness Report (New Format)

This report summarizes the results of an ultrasonic thickness survey on underground pipelines. It includes tables showing the line information, component details, original and current thickness readings, calculated corrosion rates, remaining life, and next inspection dates. Notes indicate that where no corrosion was detected, the rate was assumed to match similar lines, thickness readings were reduced by 7% for temperature, and assumptions were made about original thickness where it exceeded current readings. The report was prepared to assess long-term and short-term corrosion rates on the pipelines.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views3 pages

Thickness Report (New Format)

This report summarizes the results of an ultrasonic thickness survey on underground pipelines. It includes tables showing the line information, component details, original and current thickness readings, calculated corrosion rates, remaining life, and next inspection dates. Notes indicate that where no corrosion was detected, the rate was assumed to match similar lines, thickness readings were reduced by 7% for temperature, and assumptions were made about original thickness where it exceeded current readings. The report was prepared to assess long-term and short-term corrosion rates on the pipelines.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Ultrasonic Testing Thickness Survey Report (Long Term Corrosion Rate)

Thickness Measurement (mm)


Line Information CML Description Dates
Current Thickness Readings
Minimum
Original Minimum Corrosion Required Remaining Next Inspection
Design Elbow Outer Elbow Inner Thickness Reading Rate Thickness Life (years) Date Remarks

Bottom
CML ID

North

South
(mm) (mm) (mm/yr)

West
Piping Element Original Date of Last

East
Thickness Radius / Tee Radius

Top
Pipeline Number I/V Size (in) (mm)
Description Reading Dates Inspection
1 2 3 4 5

0 0.00 #DIV/0! #DIV/0! #DIV/0!

Note 1 : Corrosion rate was found 0.00 mm, the corrosion rate was taken to be as similar elements in the same line / service.
Note 2: Temperature correction factor was considered and all actual thickness readings was reduced by 7%.
Inspected By: Prepared By: Reviewed By:
Ultrasonic Testing Thickness Survey Report (Short Term Corrosion Rate)

Corrosion Rates
Line Information CML Description Dates Thickness Readings (mm)

(mm/year)
Minimum
Required Remaining Next Inspection
Thickness Life (years) Date Remarks
Piping Element Date of Previous Date of Last Design Previous Current (mm)
Pipeline Number I/V Description CML ID Size (in) Inspection Inspection Thickness Thickness Thickness

#DIV/0! #DIV/0! #DIV/0!

Note 1 : Corrosion rate was found 0.00 mm, the corrosion rate was taken to be as similar elements in the same line / service.
Note 2: Temperature correction factor was considered and all actual thickness readings was reduced by 7%.
Inspected By: Prepared By: Reviewed By:
NOTES:

Note 1 : The actual thickness was found more than original thickness,higher corrosion rate was taken as similar with the same line and the same calculated in short term.
Note 2 : The actual thickness was found more than original thickness, so the highest pipe schedule were used as new original thickness
Note 2 : The actual thickness was found more than original thickness,so the original thickness are 12.5% increase.
Note 2 : The actual thickness was found more than original thickness,so the original thickness are 12.5% decrease.
Note : Due to 0.00 mm corrosion allowance, as a result remaining life become negative value. The next inspection date were consider as 10 years interval as per API 570.
Note : Due to 0.00 mm corrosion allowance, the minimum required thickness were deducted by 12.5% from it's design thickness.
Note 2: Temperature correction factor was considered and all actual thickness readings was reduced by 7%.