Mitsubishi Electric

HMI
migration guide

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Contents

• End of Life Statement

• Why change to GOT?

• Why change to MAPS?

• E1000 replacements

• iX replacements

• GOT2000 cables

• GOT Migration Campaign

• Differences Beijer - GOT

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


End of Life Statement
Mitsubishi have been selling Beijer manufactured HMIs
for many years now and since their release, the E1000
and iX HMI series have proved to be very popular.
However, as some of these products are now over 10
years old the time is right for us to move on to the
more modern Mitsubishi Electric GOT2000 series.
Therefore as of 30th Nov E1000 and iX HMI products
will be discontinued and be replaced by their GOT2000
equivalents, as these enable us to offer our customers
greater performance, more features and better value
for money.

Phase out schedule:


Last time buy (LTB) – 30/11/15
Last date when Mitsubishi Electric will accept customer
orders.
End of Service (EOS) – 30/11/22
Service and support will be offered until this date,
thereafter at the discretion of Mitsubishi Electric.

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


Why change to GOT?
• Quality
• Mitsubishi Electric stands for superior quality products and
can therefore offer a 3 year warranty period.

• Integration
• The GOT HMI products integrate perfectly with the other
automation products of Mitsubishi Electric such as PLCs.
Servos, Inverters and Robots.

• Security / Stability / Speed


• The VxWorks operating system of the GOTs ensures a secure,
stable, high speed environment.

• State-of-the-Art technical specifications


• GOT products offer state-of-the-art HMI technology such as
TFT LCD colour displays, LED backlights and built-in
interfaces (Ethernet, USB, RS232, RS-422/485 SD card)

• Pre-designed screen templates


• The GOT programming environment offers a comprehensive
library of pre-designed template screens for various kind of
applications e.g. trends, alarms and Mitsubishi Electric
automation product monitoring screens.

• Key functions of GOTs


• Multi-Touch / Gesture Control • FTP Server / Client
• Multimedia Functions • Operation Log
• Debugging Functions • Data Logging
• Document Display • Multi Channel
• VNC Remote Access • FA Transparent
• Email • Operator
• MES Interface Authentication
• Backup / Restore
• Gloves? No problem….
• In dirty environments users can still operate GOT2000 HMIs
reliably due their use of resistive touchscreen technology.

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


Why change to MAPS?
• Openness
• Easy to use on any system irrespective of manufacturer

• Data logging & Database connectivity


• Enables users to accurately measure and record plant
performance

• Reporting & Alarm Management


• Live data that’s easy to understand

• Proven & Reliable


• Peace of mind

• Open scripting
• Allows users to customise applications

• Vector graphics
• Clear, scalable attractive graphics

• Real Time Software


• No compilation, online configuration

• Object oriented programming using Wizards and


Templates
• Minimised engineering time

• Flexibility to grow from MAPS HMI to full blown


SCADA system
• Wide choice of scalable products for any application size

• Windows10 ready
• Future-proof

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


Why change to MAPS HMI?

• Real Time Software


• MAPS HMI needs no compilation and no download, just online
configuration.
• Design changes are reflected instantly to the visualisation interface.

• Openness
• More than 100 drivers to 3rd party automation products are integrated
in MAPS HMI.
• Due to latest .net integration all Microsoft visual studio scripting
languages (C#, [Link]) can be used.

• Database connectivity / Historian functionality


• MAPS HMI connects to all OLE DB compliant databases for data
storage, reporting and recipe handling.

• Reporting
• By using the data in a database, users benefit from the free Microsoft
report builder and can create custom reports as well as pre-defined
reports with the MAPS HMI report suite.

• Alarm Management
• Multiple built-in alarm functionalities with groups, levels, hierarchies
and priorities to display alarm messages in a user friendly and an easy
to understand interface minimising downtime.

• Latest software technology


• Future proof software due to full integration of the latest Microsoft
Windows technologies. MAPS HMI already supports Windows 10.

• Vector graphics
• Over 300 2D & 3D static and dynamic industrial and common use
vector symbols integrated, for efficient engineering. XAML (Microsoft
vector graphics standard) offers import of additional vector graphics.

• Object oriented environment using Wizards and Templates


• Easy standardisation with an object oriented approach creating
intelligent, reusable objects in their own libraries.

• Flexibility to grow from MAPS HMI to full SCADA system


• Seamless upgrade path to expand MAPS HMI to a distributed SCADA
system.

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


E1012 to GT21 & GS21

Unit Type Display Resolution SD Card

E1012 Key Mono STN 160x32 No

GT2104-RTBD Touch 4.3" TFT Colour 480x272 

Unit RS232 RS422/485 USB Ethernet Network


options
E1012   - - Ethernet

GT2104  RS422   -

Additional Notes

GT2104 (118x92)

E1012 (121x80)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1022 to GT21 & GS21

Unit Type Display Resolution SD Card

E1022 Key Mono STN 240x64 No

GT2104-RTBD Touch 4.3" TFT Colour 480x272 

GT2107-WTBD Touch 7” widescreen TFT 800 x 480 

Unit RS232 RS422/485 USB Ethernet Network


options
E1022   - - Ethernet
GT2104/GS2107  RS422   -

Additional Notes GS2107 (191x137)

GT2104 (118x92)

E1022 (138x120)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1032 to GT21 & GS21

Unit Type Display Resolution SD Card

E1022 Key Mono STN 240x64 No

GT2104-RTBD Touch 4.3" TFT Colour 480x272 

GT2107-WTBD Touch 7” widescreen TFT 800 x 480 

Unit RS232 RS422/485 USB Ethernet Network


options
E1022   - - Ethernet
GT2104/GS2107  RS422   -

Additional Notes GS2107 (191x137)

GT2104 (118x92)

E1032 (166x149)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1041 to GT2104

Unit Type Display Resolution SD Card

E1041 Touch 3.5” TFT Colour 320x240 No

GT2104-RTBD Touch 4.3" TFT Colour 480x272 

Unit RS232 RS422/485 USB Ethernet Network


options
E1041     Profibus

GT2104-RTBD     -

Additional Notes

E1041 (139x105)

GT2104 (118x92)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1043 to GT2104

Unit Type Display Resolution SD Card

E1043 Touch 3.5” TFT Grayscale 320x240 No

GT2104-RTBD Touch 4.3" TFT Colour 480x272 

Unit RS232 RS422/485 USB Ethernet Network


options
E1043     Profibus

GT2104-RTBD     -

Additional Notes

E1043 (139x105)

GT2104 (118x92)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1060 to GS2110

Unit Type Display Resolution SD Card

E1060 Key 5.7” TFT Colour 320x240 No

GS2110-WTBD Touch 10" TFT Colour 800x480 

Unit RS232 RS422/485 USB Ethernet Network


options
E1060     Profibus

GS2110-WTBD  RS422   -

Additional Notes GS2110 (258x200)

E1060 (240x130)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1061 to GT2705

Unit Type Display Resolution SD Card

E1061 Touch 5.7” TFT Colour 320x240 No

GT2705-VTBD Touch 5.7” TFT Colour 640x480 

Unit RS232 RS422/485 USB Ethernet Network


options
E1061     Profibus

GT2705-VTBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes
E1061 (180x130)

GT2705 (153x121)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1062 to GS2110

Unit Type Display Resolution SD Card

E1062 Key 5.7” TFT Grayscale 320x240 No

GS2110-WTBD Touch 10" TFT Colour 800x480 

Unit RS232 RS422/485 USB Ethernet Network


options
E1062     Profibus

GS2110-WTBD  RS422   -

Additional Notes GS2110 (258x200)

E1062 (240x130)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1063 to GT2705

Unit Type Display Resolution SD Card

E1063 Touch 5.7” TFT Grayscale 320x240 No

GT2705-VTBD Touch 5.7” TFT Colour 640x480 

Unit RS232 RS422/485 USB Ethernet Network


options
E1063     Profibus

GT2705-VTBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes
E1063 (180x130)

GT2705 (153x121)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1070 to GT2710

Unit Type Display Resolution SD Card

E1070 Key 6.5” TFT Colour 640x480 No

GT2710-STBD Touch 10.4” TFT Colour 800x600 

Unit RS232 RS422/485 USB Ethernet Network


options
E1070     Profibus

GT2710-STBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes GT2710 (289x200)

E1070 (246x139)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1071 to GT2708

Unit Type Display Resolution SD Card

E1071 Touch 6.5” TFT Colour 640x480 No

GT2708-VTBD Touch 8.4” TFT Colour 640x480 

Unit RS232 RS422/485 USB Ethernet Network


options
E1071     Profibus

GT2708-VTBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes GT2708 (227x176)

E1071 (188x137)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1100 to GT2715

Unit Type Display Resolution SD Card

E1100 Key 10.4” TFT Colour 800x600 No

GT2715-XTBD Touch 15” TFT Colour 1024x768 

Unit RS232 RS422/485 USB Ethernet Network


options
E1100     Profibus

GT2715-XTBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes GT2715 (383.5x282.5)

E1100 (343x208)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1101 to GT2710

Unit Type Display Resolution SD Card

E1101 Touch 10.4” TFT Colour 800x600 No

GT2710-STBD Touch 10.4” TFT Colour 800x600 

Unit RS232 RS422/485 USB Ethernet Network


options
E1101     Profibus

GT2710-STBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes GT2710 (289x200)

E1101 (264.5x206)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
E1151 to GT2715

Unit Type Display Resolution SD Card

E1151 Touch 15” TFT Colour 1024x768 No

GT2715-XTBD Touch 15” TFT Colour 1024x768 

Unit RS232 RS422/485 USB Ethernet Network


options
E1151     Profibus

GT2715-XTBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes GT2715 (383.5x282.5)

E1151 (355.5x278.5)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T4A to GT2104

Unit Type Display Resolution SD Card

T4A Touch 4.3" TFT Colour 480x272 

GT2104-RTBD Touch 4.3" TFT Colour 480x272 

Unit RS232 RS422/485 USB Ethernet Network


options
T4A     CAN

GT2104-RTBD     -

Additional Notes GT2104 (153x121)

T4A (130x89)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T7A to GS2107

Unit Type Display Resolution SD Card

T7A Touch 7" TFT Colour 800x480 

GS2107-WTBD Touch 7" TFT Colour 800x480 

Unit RS232 RS422/485 USB Ethernet Network


options
T7A     CAN

GS2107-WTBD  RS422   -

GS2107 (191x137)
Additional Notes

T7A (189x128)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T10A to GT2510

Unit Type Display Resolution SD Card

T10A Touch 10.4" TFT Colour 640x480 

GT2510-VTBD Touch 10.4" TFT Colour 640x480 

Unit RS232 RS422/485 USB Ethernet Network


options
T10A     CAN

GT2510-VTBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes GS2107 (289x200)

T10A (264x211)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T7B to GS2107

Unit Type Display Resolution SD Card

T7B Touch 7" TFT Colour 800x480 

GS2107-WTBD Touch 7" TFT Colour 800x480 

Unit RS232 RS422/485 USB Ethernet Network


options
T7B     CAN

GS2107-WTBD  RS422   -

GS2107 (191x137)
Additional Notes

T7B (189x128)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T12B to GT2712

Unit Type Display Resolution SD Card

T12B Touch 12.1" TFT Colour 1280x800 

GT2712-STBD Touch 12.1" TFT Colour 800x600 

Unit RS232 RS422/485 USB Ethernet Network


options
T12B     CAN

GT2712-STBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus

Additional Notes GT2712 (302x228)

T12B (324x226)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T12B to 15” SoftGOT

alternative

Unit Type Display Resolution SD Card

T12B Touch 12.1" TFT Colour 1280x800 


SoftGOT-15 panel PC Touch 15.6" TFT Colour 1366x768 No

Unit RS232 RS422/485 USB Ethernet Network


options
T12B     CAN
SoftGOT-15 panel PC     WiFi

Additional Notes
SoftGOT-15 panel PC (388x239)

T12B (324x226)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T15B to GT2715

Unit Type Display Resolution SD Card

T15B Touch 15" TFT Colour 1280x800 

GT2715-XTBD Touch 15” TFT Colour 1024x768 

Unit RS232 RS422/485 USB Ethernet Network


options
T15B     CAN

GT2715-XTBD     *

* CC-Link. CC-Link IE. CC-Link IE Field. MELSECNET/H. Bus


GT2715 (383.5x282.5)
Additional Notes

T15B (394x270)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T15B to 15” SoftGOT

alternative

Unit Type Display Resolution SD Card

T15B Touch 15" TFT Colour 1280x800 


SoftGOT-15 panel PC Touch 15.6" TFT Colour 1366x768 No

Unit RS232 RS422/485 USB Ethernet Network


options
T12B     CAN
SoftGOT-15 panel PC     WiFi

Additional Notes

SoftGOT-15 panel PC
(388x239)

T15B (394x270)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T12C to 15” MAPS IPC

Unit Type Display Resolution SD Card

T12C Cel./i7 Touch 12.1" TFT Colour 1280x800 


MAPS-HMI -Kit-15 Touch 15.6" TFT Colour 1366x768 No

Unit RS232 RS422/485 USB Ethernet Network


options
T12C Cel./i7     CAN
MAPS-HMI -Kit-15     WiFi

Additional Notes
MAPS-HMI -Kit-15 (388x239)

T12C (324x226)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T15C to 15” MAPS IPC

Unit Type Display Resolution SD Card

T15C Celeron Touch 15.4" TFT Colour 1280x800 


MAPS-HMI -Kit-15 Touch 15.6" TFT Colour 1366x768 No

Unit RS232 RS422/485 USB Ethernet Network


options
T15C Celeron     CAN
MAPS-HMI -Kit-15     WiFi

Additional Notes

MAPS-HMI -Kit-15 (388x239)

T15C (394x270)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T15C to 15” MAPS IPC

Unit Type Display Resolution SD Card

T15C i7 Touch 15.4" TFT Colour 1280x800 


MAPS-HMI -Kit-15 Touch 15.6" TFT Colour 1366x768 No

Unit RS232 RS422/485 USB Ethernet Network


options
T15C i7     CAN
MAPS-HMI -Kit-15     WiFi

Additional Notes

MAPS-HMI -Kit-15
(388x239)

T15C (394x270)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T15C to 18.5” MAPS IPC

alternative

Unit Type Display Resolution SD Card

T15C i7 Touch 15.4" TFT Colour 1280x800 


MAPS-HMI -Kit-18 Touch 18.5" TFT Colour 1366x768 No

Unit RS232 RS422/485 USB Ethernet Network


options
T15C i7     CAN
MAPS-HMI -Kit-18     WiFi

Additional Notes
MAPS-HMI -Kit-18 (454x279)

T15C (394x270)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
T21C to 21” MAPS IPC

Unit Type Display Resolution SD Card

T21C Cel./i7 Touch 21.5" TFT Colour 1920x1080 


MAPS-HMI -Kit-22 Touch 21.5" TFT Colour 1920x1080 No

Unit RS232 RS422/485 USB Ethernet Network


options
T21C Cel./i7     CAN
MAPS-HMI -Kit-22     WiFi

Additional Notes
MAPS-HMI -Kit-22 (520x316)

T21C (539x331)
Panel Cut out (Approx. to scale)
COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
GOT Cables

For details please check:

“GOT2000 Connection Manual (Mitsubishi Products)”

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


GOT Migration Campaign
• Project conversion support
• Mitsubishi can provide help with converting a Beijer HMI
project to GOT. Please contact your local sales partner.

• Application consultants
• Our team of local application engineers can help you with
your questions about.

• Free GT Works 3 software and start-up guide


• When converting to GOTs you can receive a free-of-charge
version of GT Works to program GOTs together with a start-
up-guide.
• Hotline support
• There is a team of knowledgeable engineers to assist you
with conversion within Mitsubishi Electric and our sales
partners.

• Product training
• Comprehensive training courses for GOTs and GT Designer
are available.

• 3-year warranty
• Mitsubishi Electric offers an exceptional 3 year warranty on
all GT2000 products.

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.


Differences Beijer - GOT
• Webserver
• Beijer HMIs offer a webserver functionality, whereas GOTs
will offer a more flexible alternative (GT mobile) by the
end of 2015.

• Profibus
• Beijer E1000 products offer optional Profibus connectivity
whilst GOTs can connect by using an HMS fieldbus adapter
(GT25-FNADP).

• WLAN
• GOTs have an optional WLAN module for monitoring and
project up/download which is not available on the Beijer
HMIs.

• Siemens MPI
• Beijer HMI can connect to a Siemens S7 via a CAB36 cable
whereas GOTs require an external MPI adapter.

• Multimedia/documents
• E1000s have no multimedia or document display functions
whereas GOT2000s can display pdf, ppt, xls, doc and
HTML documents (using the built-in conversion utility)

• Materials
• Instead of the alloy housing of the Beijer HMIs. the GOTs
are made of robust plastic.

• Recipe handling systems


• The recipe handling of GOTs will be improved to match the
expectations for former Beijer users by April 2016.

COPYRIGHT © 2012 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.