MOTOR INFORMATION
Device Number 88QV-1A
MLI ref.No. A160 Motor Name Mist Eliminator
88QV-1B
MOTOR DATA TO BE SUBMITTED
Manufacturer GE Model 5KS184SA
A1139
HP 5 Volts 460 Phase 3
Service Factor 1.15 Temp. Rise by Resistance at Service Factor 104 (40) °F(°C)
(not to exceed 80°C if service factor is 1.0. not to exceed 90° if service factor is 1.15 for 460 volt motors; not to exceed 80° for all 4000 volt motors.)
NEMA Load AMP, Locked- In Rush
B Rotor Current
46 AMP 40.24 AMP
Letter Current
NEMA Design Full Load Full Load
B 3600 RPM 6.1 AMP
Letter Speed Current
Enclosure Type TEFC Frame Size 184T 10.2
Acceleration Time Sec
Safe Stall Time: 26 cold / 12 hot
Insulation System
Mark with an X on both items (Class & Seal) Add Temperature
Class (check one) Seal (check one) Ambient Temp
With two dips
and bakes of
A B Other VPI epoxy
Others °F (°C)
varnish
H X 149 65
Space Heater Required 10Hp or Larger: Number of 120Volt, single-phase.
Units if 1.000 W or less 1 Unit Rating, Watts 25
Bearings
TYPE: Please select one: Mark with an X
Split-sleeve ring Spherical Roller Thrust Others X Ball
AFBMA L-10 Rating Life : Not less than…Please select one: Mark with an X
100.00 H if direct coupled x 30,000 H if Belt or Chain connected
OTHER
Lubrication Type:Please select one: Mark with an X
Oil Grease x
TOTAL MOTOR WEIGHT
Pounds (Lb) 102 Kilograms (Kg) 46