Olympus JF-260V Duodenovideoscope Features

The document summarizes the specifications and features of the Olympus JF-260V duodenoscope. It has a large 3.7mm instrument channel to accommodate various ERCP procedures including stent placement. It features an innovative V-groove forceps elevator that simplifies device manipulation during ERCP procedures. The scope has a slim distal end of 12.6mm for good insertion capability and 4-way angulation for approaching the papilla of Vater.

Uploaded by

HAITHM MURSHED
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
342 views3 pages

Olympus JF-260V Duodenovideoscope Features

The document summarizes the specifications and features of the Olympus JF-260V duodenoscope. It has a large 3.7mm instrument channel to accommodate various ERCP procedures including stent placement. It features an innovative V-groove forceps elevator that simplifies device manipulation during ERCP procedures. The scope has a slim distal end of 12.6mm for good insertion capability and 4-way angulation for approaching the papilla of Vater.

Uploaded by

HAITHM MURSHED
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

EVIS LUCERA DUODENOVIDEOSCOPE

OLYMPUS JF TYPE 260V


3.2mm CV-260/CV-240
12.6mm 3.7 mm
3.2mm CV-200

Wide 3.7 mm channel suits a wide


spectrum of ERCP procedures including
placement of a 10 Fr. stent
Incorporating a large 3.7 mm diameter channel, the JF-260V can be
used in a wide range of ERCP procedures — from cannulation to V-System device replacement procedure

placement of a 10 Fr. stent. It’s also easier to use thanks to the innovative
Confirm the position of the V-Marking
V-Groove forceps elevator which simplifies device manipulation on the Endo-Therapy accessory.
and replacement.

When the V-Marking is completely visible


above the instrument channnel port,
raise the forceps elevator to lock the guidewire.

Be sure that the guidewire is


locked in the V-Groove.

V-Groove forceps elevator Completely remove the device.


The innovative design of the forceps elevator Conventional forceps elevator V-Groove forceps elevator
on the JF-260V allows it to be raised at a V-Groove
sharper angle than a conventional scope
elevator, while its unique V-shaped guidewire
locking groove combines with the dedicated
guidewire’s reactive force to securely lock the
Guide wire Linear GuideV
guidewire in position.
● Large instrument channel measures 3.7 mm
across for expanded treatment options in the
bile and pancreatic ducts.
● Innovative V-Groove forceps elevator offers
reliable duodenoscopic treatment capability
in combination with dedicated V-System
ERCP devices.
● Slim design — measuring 12.6 mm across
at the distal end and 11.3 mm across at the
insertion tube — for excellent insertion
capability.
● 4-way angulation (120° up, 90° down, 110º
right, and 90° left) facilitates approach to
the papilla of Vater.
● Ergonomically designed grip enhances
torque performance and scope
maneuverability while easy-to-access
control knobs improve operability.
● Detachable distal cover
for easiercleaning of Optional System Field of view 100º
the scope tip. Direction of view 15º Backward oblique viewing
Depth of field 5 to 60 mm
Distal End Outer diameter 12.6 mm
● Fully compatible with the CV-260, CV-240
Insertion Tube Outer diameter 11.3 mm
and CV-200. Bending Section Angulation range Up 210º, Down 90º, Right 110º, Left 90º
● Scope ID function retains individual scope Working Length 1240 mm
information in the memory chip and Total Length 1550 mm
displays it on the monitor. Also stores Instrument Channel Inner diameter 3.7 mm
settings such as auto white balance to Minimum visible distance 10 mm from distal end
Endo-Therapy accessory entrance/exit position in field of view
facilitate endoscopy suite management.
Laser Compatibility NO
High-Frequency Compatibility YES
Scope ID Function YES

Objective Lens
Up 120° Air/water Nozzle
Left 90°
Light Guide

Instrument Channel V-Groove


Down 90° Right 110°
Forceps Elevator

3.2mm CV-260/CV-240
12.6mm 3.7 mm
3.2mm CV-200

  
  