05–60
DIAGNOSTICS – SFI SYSTEM (April, 2003) 05AI8–04
DTC P0031 OXYGEN SENSOR HEATER CONTROL
CIRCUIT LOW (BANK 1 SENSOR 1)
DTC P0032 OXYGEN SENSOR HEATER CONTROL
CIRCUIT HIGH (BANK 1 SENSOR 1)
DTC P0037 OXYGEN SENSOR HEATER CONTROL
CIRCUIT LOW (BANK 1 SENSOR 2)
DTC P0038 OXYGEN SENSOR HEATER CONTROL
CIRCUIT HIGH (BANK 1 SENSOR 2)
CIRCUIT DESCRIPTION
Refer to DTC P0130 on page 05–101.
HINT:
The ECM provides a pulse width modulated control circuit to adjust current through the heater. The heated
oxygen sensor heater circuit uses a relay on the B+ side of the circuit.
Reference (Bank 1 Sensor 1 System Drawing):
EFI Relay ECM
Heated Oxygen Sensor
From EFI Fuse Heater HT1A
Battery
Sensor OX1A
From
Duty
Terminal 6 of
Control
Ignition Switch
Ground Ground
A82244
DTC No. DTC Detection Condition Trouble Area
P0031 Heated current is 0.25 A or less when heater operates with B+ Open or short in heater circuit of heated oxygen sensor
P0037 greater than 11.5 V (1 trip detection logic) Heated oxygen sensor heater
P0032 Heated current exceeds 3.5 A when heater operates EFI relay
P0038 (1 trip detection logic) ECM
2004 COROLLA (RM1037U)
Author: Date: 225