Page 1 of 8
Siemens Controller
Siemens Controller>>Software
Network Connection with License
1. Execute Automation License Manager program
Confirm RCS 802 License key.
Without License key
V1.2 version can’t connect the network.
V1.4 version can only use peer to peer function to connect the network, and the
SNAP SHOT function is not enabled.
2. Siemens 802D-SL connection setting.
Press SHIFT+ALARM
Press Service display
Press Service control
[Link] 2009/3/13
Page 2 of 8
Confirm NC IP address is [Link] (you can change it)
Press Authorization
Press Create
Input User/Password/Confirm is XYZC for example, press OK.
Press Back <<
[Link] 2009/3/13
Page 3 of 8
Press Back <<
Press Previous Screen
Press RCS log in
Input User/Password is XYZC for example , press Log in.
[Link]
RCS Program
RCS tool (Remove Control System)
[Link] 2009/3/13
Page 4 of 8
OVERHAUL
Press Connect button
OF
PROCESS
Press Configure…
[Link] 2009/3/13
Page 5 of 8
Confirm NC IP address is [Link] (you can change it)
If you want PC control three NC through a hub, then each NC must have
different IP address.
For example :
NC 1 IP : [Link]
NC 2 IP : [Link]
NC 3 IP : [Link]
And PC IP address is [Link]
You can send a program file to NC 1 just change the RCS connect IP address
to [Link]
Press OK button.
Input the User name and Password is XYZC for example.
Connect network successfully.
[Link] 2009/3/13
Page 6 of 8
Press SNAP SHOT button (PC window resolution is 640x480)
Network Connection without License
[Link]
Press SHIFT+ALARM
Press Service display
Press Service control
Press Direct connect
IP address is [Link] (you can’t change)
2. PC
Run RCS Program(V01.04.11.00)
Select Ethernet peer to peer ,press connect button.
PS. License is not necessary.
[Link] 2009/3/13
Page 7 of 8
The IP address is fixed , you can’t change it. Press OK
It shows NC directory and files.
[Link] 2009/3/13
Page 8 of 8
[Link] 2009/3/13