Siemens Controller Siemens Controller Software

The document provides instructions for connecting a Siemens controller to a network. It outlines three key steps: 1) executing the automation license manager program and confirming the license key; 2) configuring the Siemens 802D-SL connection settings including IP address; and 3) running the RCS program to connect to the controller over the network. It also notes that without a valid license, only a peer-to-peer connection is possible.

Uploaded by

Tony Antony
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
226 views8 pages

Siemens Controller Siemens Controller Software

The document provides instructions for connecting a Siemens controller to a network. It outlines three key steps: 1) executing the automation license manager program and confirming the license key; 2) configuring the Siemens 802D-SL connection settings including IP address; and 3) running the RCS program to connect to the controller over the network. It also notes that without a valid license, only a peer-to-peer connection is possible.

Uploaded by

Tony Antony
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Page 1 of 8

Siemens Controller
Siemens Controller>>Software

Network Connection with License

1. Execute Automation License Manager program


Confirm RCS 802 License key.

Without License key




V1.2 version can’t connect the network.


V1.4 version can only use peer to peer function to connect the network, and the
SNAP SHOT function is not enabled.

2. Siemens 802D-SL connection setting.


Press SHIFT+ALARM
Press Service display
Press Service control

[Link] 2009/3/13
Page 2 of 8

Confirm NC IP address is [Link] (you can change it)

Press Authorization
Press Create
Input User/Password/Confirm is XYZC for example, press OK.

Press Back <<

[Link] 2009/3/13
Page 3 of 8


Press Back << 
Press Previous Screen
Press RCS log in 
Input User/Password is XYZC for example , press Log in.

[Link]
RCS Program  

RCS tool (Remove Control System)

[Link] 2009/3/13
Page 4 of 8

OVERHAUL
Press Connect button
OF

PROCESS


Press Configure… 


[Link] 2009/3/13
Page 5 of 8


Confirm NC IP address is [Link] (you can change it)
If you want PC control three NC through a hub, then each NC must have
different IP address.
For example :
NC 1 IP : [Link]
NC 2 IP : [Link]
NC 3 IP : [Link]
And PC IP address is [Link]
You can send a program file to NC 1 just change the RCS connect IP address
to [Link]

Press OK button.

Input the User name and Password is XYZC for example.


Connect network successfully.


[Link] 2009/3/13
Page 6 of 8



Press SNAP SHOT button (PC window resolution is 640x480) 
Network Connection without License
[Link]
Press SHIFT+ALARM 
Press Service display 
Press Service control 
Press Direct connect 
IP address is [Link] (you can’t change)



2. PC
Run RCS Program(V01.04.11.00)  

Select Ethernet peer to peer ,press connect button.


PS. License is not necessary.


[Link] 2009/3/13
Page 7 of 8


The IP address is fixed , you can’t change it. Press OK 



It shows NC directory and files.


[Link] 2009/3/13
Page 8 of 8

[Link] 2009/3/13