Fire Pump System Offer Details

This document provides a technical quote for a fire pump system for R.P. Alejandro Construction Inc. The system includes a vertical turbine fire pump that can supply 500 GPM at 125 PSI, driven by a 50 HP motor. It also includes a fire pump controller, jockey pump, and various accessories like a relief valve, waste cone, and flow meter. The total estimated weight of the system is 1836 pounds. Engineering tests on the pump and certified performance testing are included.

Uploaded by

LEONEL SOTTO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
223 views3 pages

Fire Pump System Offer Details

This document provides a technical quote for a fire pump system for R.P. Alejandro Construction Inc. The system includes a vertical turbine fire pump that can supply 500 GPM at 125 PSI, driven by a 50 HP motor. It also includes a fire pump controller, jockey pump, and various accessories like a relief valve, waste cone, and flow meter. The total estimated weight of the system is 1836 pounds. Engineering tests on the pump and certified performance testing are included.

Uploaded by

LEONEL SOTTO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Encompass 2.0 - 21.2.

Customer Technical Offer


Customer R.P. Alejandro Construction Inc Size / Stages /
Item number Copy (2) of 001-W - 380v Pump speed
Customer reference Quote number 2177-06-21-48OO51

Pump
Qty Description
1 Vertical Turbine Fire Pump 11M
COS
Conditions of service
Flow: 500 USgpm (114 m3/h)
Pressure required at flange: 125 psi (8.62 bar)
Pump Speed: 1770 RPM
Maximum lift: 7.73 ft. (2.36 m.)
Bowl pressure: 128.35 psi (8.85 bar)
Overall Length: 125.8 in (10.48 ft. / 3.2 m.)
UL Listed: Yes
FM Approved: Yes
Elevation: 300 ft. (91.44 m.)
Ambient temp: 77°F (25°C)
Pump BHP: 57 Hp
Overall length confirmation: Confirming overall length of pump is 125.8 in (10.48 ft. / 3.2 m.) as measured from the bottom of the soleplate to the
bottom of the suction strainer.
Fire pump configuration
Pump
Vertical pump module
Bowl assembly: 6 stage, 11M
Basket Strainer: Bronze
Discharge head: 16.5" X 6", "D"
Discharge head rating: 125 Lb.
Threaded column: Length 5 Ft., Size 6"
Open line shaft: Length 5 Ft., Size 1-1/4"
Total column: Length 4.42 Ft.
Fittings module: Discharge pressure gauge & 2" Automatic air release valve

Driver
Qty Description
1 Driver
Driver type
Motor: Special Motor - Selected parameters: 50 hp, 1770 RPM, 3/60/380, WP-1, Wye-Delta-Open:
XDD Motor - VHS motor with Non-Reverse Ratchet - NEMA B Design, WP-1 Enclosure (IP23), 326TP Frame, 1800 rpm, High Thrust, Class B
Temp, Class F Insulation, 6-leads, Wye-Delta, Energy Efficient IE2, UL listed, 1.15SF, 50 HP, 3/60/380V, 16.5 in BD, VHS-326TP-4-50-X-3-G-L-
B-N-STD-STD
Motor shipping: Ship from factory

Fire Pump Controller


Qty Description
1 Fire pump controller
Fire pump controller
Fire pump controller: Eaton FD70, Wye-Delta-Open, 380V, 60Hz, 50 HP
Transfer Switch: No
Fire pump controller - alarm and indicators
Standard status LED's
Power on
Pump running

Triumph Machinery Corporation · 1354 Pablo Ocampo Sr. Ext. · Makati City, San Antonio Village 1203
phone: +632 899 6286 ·
Encompass 2.0 - 21.2.4

Fire Pump Controller


Qty Description
Local start
Remote start
Deluge valve
Emergency start
Interlock on
Low pressure
Auto shutdown enabled
Standard alarm LED's
Phase reversal
Phase failure
Fail to start
Undervoltage
Overvoltage
Low room temperature
Locked rotor trip
Low suction pressure
Source 2 disconnected
Standard output relays
Startup
Acceleraion
Phase failure
Phase reversal
Common alarm
Pump running
Future 1
Fire pump controller - additional option selections
Enclosure: NEMA 2 - Standard
Space heater: 120 / 220VSpace heater
Pressure transducer: 300 PSI for fresh water
Pressure transducer mounting: Externally mounted
Language: English

Jockey Pump
Qty Description
1 Jockey pump
Pump and Motor
Pump type: None
Motor Voltage: 380 Volt

Jockey Pump Controller


Qty Description
1 Jockey pump
Pump and Motor
Motor HP: 5 Hp
Controller
JP controller details: Eaton Model XTJP-G06, Across-The-Line, 380-415V, 3 Phase, 50/60 Hz, 5 Hp
Manufacturer: Eaton
Starting method: Across-The-Line
Voltage: 380 V
Horsepower: 5 Hp
Jockey pump controller options
Pressure transducer rating: 0-500 psi - Fresh water

Triumph Machinery Corporation · 1354 Pablo Ocampo Sr. Ext. · Makati City, San Antonio Village 1203
phone: +632 899 6286 ·
Encompass 2.0 - 21.2.4

System Accessories
Qty Description
1 Accessories
System Accessories
Hose valve manifold: None
Angle type hose valves: None
Ball drip valve: None
Main relief valve: 3", 125 lb, Kunkle valve Flow range (250 - 500 US GPM)
Enclosed waste cone details: 3" X 5", waste cone
Flow meter details: Global Vision Venturi type, Grooved, 500 GPM, size 6"
Vertical turbine water level kit: None

Engineering Tests
Qty Description
1 Testing and Certifications
Driver and Engineering Tests / SASO Compliance
Is any additional testing required?: Yes
Driver to be used for engineering tests: Calibrated test lab motor
Engineering tests
Certified performance test
Performance test of Bowl Assembly, non-witnessed
Hydrostatic test of Bowl and Head, non-witnessed

Weight, Freight, Boxing


Qty Description
1 Fire pump weight: 1362 lb / 617.79 kg
Driver weight: 0 lb / 0 kg
Fire pump controller weight: 315 lb / 142.88 kg
Jockey pump controller weight: 0 lb / 0 kg
Angle type hose valve weight: 0 lb / 0 kg
Main relief valve weight: 95 lb / 43.09 kg
Waste cone weight: 42 lb / 19.05 kg
Flow meter weight: 22 lb / 9.98 kg
Total weight: 1836 lb / 832.8 kg

Added specials
Qty Description
1 Motor shipping fee Deduct