Anode Calculation Template

This document provides calculations for a cathodic protection sacrificial system for a jetty and river water intake piles. It calculates a 25 year lifetime with current densities of 20 mA/sq.m for river mud and 54 mA/sq.m for river water. It determines the required weight of magnesium anodes needed to protect different pile sections of the jetty based on their surface areas, current demands, consumption rates and utilization factors over the calculated 25 year period. The total weight of anodes proposed for protection is 100,620 kg.

Uploaded by

Fian Ardiyana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
723 views1 page

Anode Calculation Template

This document provides calculations for a cathodic protection sacrificial system for a jetty and river water intake piles. It calculates a 25 year lifetime with current densities of 20 mA/sq.m for river mud and 54 mA/sq.m for river water. It determines the required weight of magnesium anodes needed to protect different pile sections of the jetty based on their surface areas, current demands, consumption rates and utilization factors over the calculated 25 year period. The total weight of anodes proposed for protection is 100,620 kg.

Uploaded by

Fian Ardiyana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Date : Nov 11th 2021

Rev :B
CATHODIC PROTECTION SACRIFICIAL SYSTEM FOR JETTY & RWI PILE

DATA :
CALCULATED LIFE TIME (Y) 25 Years
CURRENT DENSITY
- CURRENT DENSITY FOR RIVER MUD 20.00 mA/sq.m
COATING BREAKDOWN 22 %
CURRENT DENSITY BY CALC
- CURRENT DENSITY FOR RIVER MUD (CD1) 4.40 mA/sq.m
- CURRENT DENSITY FOR RIVER WATER 54 mA/sq.m
COATING BREAKDOWN 32 %
CURRENT DENSITY BY CALC
- CURRENT DENSITY FOR RIVER WATER (CD2) 17.22 mA/sq.m
CONSUMPTION RATE OF MAGNESIUM(CON) 7.5 [Link]/Y
UTILIZATION FACTOR (U) 0.60
PROPOSED ANODE WEIGHT (N) 30.0 Kg

NOTES AND FORMULAS :


Dia = Diameter of Pipe
L = Length of Pipe
Ap = Surface Area to be protected = (3.14 x Dia x L)
Ip = Required Protection current (Current Demand) = Ap x CD
Wt = Required Weight of Anode = Ip x Y x Con : U
Nos = Number of anodes required by Weight = Wt : N
N = Proposed Anode Weight

Length Length Nos per Proposed Total Weight of


Dia
SECTION Buried Exposed Number pile Anode Anode proposed
of Piles
(m) (m) (m) (pcs) Qty (kg)
[Link] 0.711 48.0 0.2 53 20.00 1,060.00 31800.00
[Link] 0.711 37.0 8.2 22 16.00 352.00 10560.00
[Link] 0.711 45.0 8.2 34 19.00 646.00 19380.00
[Link] 0.250 35.0 8.2 10 6.00 60.00 1800.00
[Link] 0.610 40.0 8.2 24 15.00 360.00 10800.00
[Link] 0.610 29.0 0.2 48 10.00 480.00 14400.00
[Link] 0.610 30.1 2.2 36 11.00 396.00 11880.00
[Link] 0.610 30.3 0.2 28 11.00 308.00 9240.00
TOTAL 100,620.00