0% found this document useful (0 votes)
237 views3 pages

Concrete Pier Design Summary

The document summarizes the design of a concrete pier with a diameter of 24 inches, length of 10 feet, and reinforcement of 8 #7 vertical rebars. It was designed to support factored axial, moment, and shear loads of 100 kips, 200 ft-kips, and 20 kips respectively based on ACI 318-05 code. The summary includes the material strengths, loads, and reinforcement details. It then analyzes the pier capacity for various load conditions and confirms the design is adequate and satisfies all code requirements.

Uploaded by

ARAVIND
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
237 views3 pages

Concrete Pier Design Summary

The document summarizes the design of a concrete pier with a diameter of 24 inches, length of 10 feet, and reinforcement of 8 #7 vertical rebars. It was designed to support factored axial, moment, and shear loads of 100 kips, 200 ft-kips, and 20 kips respectively based on ACI 318-05 code. The summary includes the material strengths, loads, and reinforcement details. It then analyzes the pier capacity for various load conditions and confirms the design is adequate and satisfies all code requirements.

Uploaded by

ARAVIND
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Concrete Pier Design Based on ACI 318-05

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc ' = 3 ksi
VERT. REBAR YIELD STRESS fy = 60 ksi
PIER DIAMETER D = 24 in
PIER LENGTH L = 10 ft
FACTORED AXIAL LOAD Pu = 100 k
FACTORED MOMENT LOAD Mu = 200 ft-k
FACTORED SHEAR LOAD Vu = 20 k
PIER VERT. REINF. 8 # 7
SEISMIC DESIGN (ACI 21.10.4) ? Yes
LATERAL REINF. OPTION (0=Spirals, 1=Ties) 1 Ties
LATERAL REINFORCEMENT # 4 @ 6 in o.c.
(spacing 3.0 in o.c. at top end of 10.0 ft.)
(IBC/CBC 1810 & ACI 21.10.4)

THE PIER DESIGN IS ADEQUATE.

ANALYSIS
CHECK PIER LIMITATIONS
fc' = 3 ksi > 2.5 ksi
[Satisfactory] (IBC 1812.3)
D= 24 in > MAX( L / 12 , 24 in)
[Satisfactory] (IBC 1812.2)

CHECK FLEXURAL & AXIAL CAPACITY


2 0.85 f '
C  '
o  , E c  57 f C , E s  29000ksi
Ec

        2
 ' c  c  ,
0.85 f C  2     for 0   c   o
f C     o    o  
 '


0.85 f C , for  c   o

 s E s , for  s   y

f S 
f , for  s   y
 y

f Pmax =F f [ 0.85 fc' (Ag - Ast) + fy Ast] = 743.26 kips., (at max axial load, ACI 318-05, Sec. [Link])
where F = 0.8 , ACI 318-05, Sec. [Link] or [Link]
f = 0.65 (ACI 318-05, Sec.[Link]) > Pu [Satisfactory]
Ag = 452 in .
2
Ast = 4.80 in .2

1000 f Pn (kips) f Mn (ft-kips)


AT COMPRESSION ONLY 743 0
800
AT MAXIMUM LOAD 743 108
AT 0 % TENSION 639 161
600
f Pn (k) AT 25 % TENSION 527 198
400
AT 50 % TENSION 432 215
AT e t = 0.002 288 222
200 AT BALANCED CONDITION 282 224
AT e t = 0.005 96 234
0 AT FLEXURE ONLY 0 174
0 50 100 150 200 250
AT TENSION ONLY -259 0
-200

-400
0 50 100 150 200 250
-200

-400
f Mn (ft-k)
(cont'd)
a = Cbb1 = 10 in (at balanced strain condition, ACI 10.3.2)
0.7 + ( et - 0.002 ) (200 / 3), for Spiral
f= = 0.656 (ACI 318-05, Fig. R9.3.2)
0.65 + ( et - 0.002 ) (250 / 3), for Ties

where Cb = d ec / (ec + es) = 12 in et = 0.002069 ec = 0.003


d = 20.1 in, (ACI 7.7.1) b1 = 0.85 ( ACI 318-05, Sec. [Link] )

f Mn = 0.9 Mn = 174 ft-kips @ Pn = 0, (ACI 318-05, Sec. 9.3.2) ,& et,max = 0.004, (ACI 318-05, Sec. 10.3.5)
f Mn = 234 ft-kips @ Pu = 100 kips > Mu [Satisfactory]
rmax = 0.08 (ACI 318-05, Section 10.9) rprovd = 0.011
rmin = 0.005 (IBC, Section 1810.1.2.2) [Satisfactory]

CHECK SHEAR CAPACITY


f Vn = f (Vs + Vc) = 86 kips, (ACI 318-05 Sec. 11.1.1)
> Vu [Satisfactory]
where f = 0.75 (ACI 318-05 Sec. [Link])
A0 = 316 in2. Av = 0.40 in2. fy = 60 ksi
Vc = 2 (fc') A0 =
0.5
34.6 kips, (ACI 318-05 Sec. 11.3.1, [Link])
Vs = MIN (d fy Av / s , 8 (fc')0.5A0) = 80.3 kips, (ACI 318-05 Sec. [Link] & [Link])
smax = 10.5 (IBC 06 , Section 1810.1.2.2) sprovd = 6 in
smin = 1 [Satisfactory]
rs = 0.12 fc' / fyt = 0.006 < rs,provd = 0.008 [Satisfactory] (ACI 318-05 Sec. [Link] & [Link])