AML : Principal data
ZD type : ZD 2800 VSD
ZR type : ZR315 VSD-10,4 FF
D type : DN250VSD-10,4
Reference conditions
1 Inlet pressure bar (a) 1
2 Relative air humidity % 0
3 Air inlet temperature °C 20
4 Cooling water inlet temperature °C 20
5 Nominale effective working pressure bar (g) 30 40
6.1 Motor shaft speed ZR rpm 2298 2238
6.2 Motor shaft speed D rpm 1043 1071
Limitations
1 Maximum pressure ratio (1) 48
2 Maximum effective working pressure bar (g) 42
3 Minimum effective working pressure (2) bar (g) 25
4 Maximum allowable air inlet temperature °C 40
5 Minimum allowable air inlet temperature °C 0
6 Maximum allowable ambiant temperature °C 40
7 Maximum allowable cooling water inlet temperature °C 35
8 Minimum allowable cooling water inlet temperature °C 5
9 Maximum allowable cooling water outlet temperature (3) °C 50
10 Maximum effective cooling water inlet pressure bar (g) 6
11 Maximum load / unload cycle quantity min-1 3
Performance data (4)
1 Flow
1.1 FAD (5)
at reference conditions 30B 40B 30B 40B l/s 570 554
at effective motor speeds ZR at 1407 1347 rpm D at 595 595 rpm l/s 325 308
1585 1525 rpm 687 693 rpm l/s 375 359
1763 1703 rpm 778 790 rpm l/s 425 409
1941 1881 rpm 868 885 rpm l/s 474 458
2120 2060 rpm 957 979 rpm l/s 523 507
2298 2238 rpm 1043 1071 rpm l/s 570 554
2476 2416 rpm 1129 1162 rpm l/s 617 602
2654 2594 rpm 1213 1251 rpm l/s 663 648
2832 2772 rpm 1296 1339 rpm l/s 708 693
2951 2951 rpm 1350 1426 rpm l/s 738 738
2970 0005 07
1/5
2970 0005 06
Registration code
Collection : APC ZD 2800 VSD
Tab : 15
1901 0625 92
Ed. : 07
date 25-Mar-11
ZD : ZD 2800 VSD
AML : Principal data
ZD type : ZD 2800 VSD
ZR type : ZR315 VSD-10,4 FF
D type : DN250VSD-10,4
1.2 Flow
at reference conditions 30B 40B 30B 40B Nm3/h 1,887 1,835
at effective motor speeds ZR at 1407 1347 rpm D at 595 595 rpm Nm3/h 1,077 1,020
1585 1525 rpm 687 693 rpm Nm3/h 1,243 1,187
1763 1703 rpm 778 790 rpm Nm3/h 1,408 1,353
1941 1881 rpm 868 885 rpm Nm3/h 1,571 1,516
2120 2060 rpm 957 979 rpm Nm3/h 1,731 1,678
2298 2238 rpm 1043 1071 rpm Nm3/h 1,887 1,835
2476 2416 rpm 1129 1162 rpm Nm3/h 2,043 1,991
2654 2594 rpm 1213 1251 rpm Nm3/h 2,195 2,144
2832 2772 rpm 1296 1339 rpm Nm3/h 2,345 2,295
2951 2951 rpm 1350 1426 rpm Nm3/h 2,443 2,444
2 Power data
2.1 Performance data based on shaft input
2.1.1 Shaft input at reference conditions 30B 40B 30B 40B kW 336 348
at effective motor speeds ZR at 1407 1347 rpm D at 595 595 rpm kW 192 193
1585 1525 rpm 687 693 rpm kW 220 223
1763 1703 rpm 778 790 rpm kW 248 253
1941 1881 rpm 868 885 rpm kW 277 284
2120 2060 rpm 957 979 rpm kW 307 316
2298 2238 rpm 1043 1071 rpm kW 336 348
2476 2416 rpm 1129 1162 rpm kW 367 380
2654 2594 rpm 1213 1251 rpm kW 398 413
2832 2772 rpm 1296 1339 rpm kW 429 447
2951 2951 rpm 1350 1426 rpm kW 450 481
2.1.2 Specific shaft input requirement
at reference conditions 30B 40B 30B 40B J/l 590 627
at effective motor speeds ZR at 1407 1347 rpm D at 595 595 rpm J/l 590 628
1585 1525 rpm 687 693 rpm J/l 585 621
1763 1703 rpm 778 790 rpm J/l 583 620
1941 1881 rpm 868 885 rpm J/l 584 620
2120 2060 rpm 957 979 rpm J/l 586 623
2298 2238 rpm 1043 1071 rpm J/l 590 627
2476 2416 rpm 1129 1162 rpm J/l 594 632
2654 2594 rpm 1213 1251 rpm J/l 599 638
2832 2772 rpm 1296 1339 rpm J/l 605 645
2951 2951 rpm 1350 1426 rpm J/l 609 652
2.1.3 Shaft input at no load and reference conditions (6) kW 42.10
2970 0005 07
2/5
2970 0005 06
Registration code
Collection : APC ZD 2800 VSD
Tab : 15
1901 0625 92
Ed. : 07
date 25-Mar-11
ZD : ZD 2800 VSD
AML : Principal data
ZD type : ZD 2800 VSD
ZR type : ZR315 VSD-10,4 FF
D type : DN250VSD-10,4
2.2 Performance data based on packaged compressor power input (7)
2.2.1 Power at reference conditions 30B 40B 30B 40B kW 365 377
at effective motor speeds ZR at 1407 1347 rpm D at 595 595 rpm kW 211 213
1585 1525 rpm 687 693 rpm kW 240 244
1763 1703 rpm 778 790 rpm kW 271 277
1941 1881 rpm 868 885 rpm kW 302 309
2120 2060 rpm 957 979 rpm kW 333 343
2298 2238 rpm 1043 1071 rpm kW 365 377
2476 2416 rpm 1129 1162 rpm kW 398 412
2654 2594 rpm 1213 1251 rpm kW 430 448
2832 2772 rpm 1296 1339 rpm kW 464 484
2951 2951 rpm 1350 1426 rpm kW 486 520
2.2.2 Specific power requirement
at reference conditions 30B 40B 30B 40B J/l 640 681
at effective motor speeds ZR at 1407 1347 rpm D at 595 595 rpm J/l 648 691
1585 1525 rpm 687 693 rpm J/l 640 681
1763 1703 rpm 778 790 rpm J/l 637 676
1941 1881 rpm 868 885 rpm J/l 636 676
2120 2060 rpm 957 979 rpm J/l 637 677
2298 2238 rpm 1043 1071 rpm J/l 640 681
2476 2416 rpm 1129 1162 rpm J/l 644 685
2654 2594 rpm 1213 1251 rpm J/l 649 691
2832 2772 rpm 1296 1339 rpm J/l 655 697
2951 2951 rpm 1350 1426 rpm J/l 659 705
2.2.3 Power at no load and reference conditions (6) kw 50.10
2.2.4 Low load kit kw 9.0
3 Interstage pressure
3.1 1st stage bar (g) 2.3
3.2 2nd stage bar (g) 9.5
3.3 3rd stage bar (g) 18.5 19.9
2970 0005 07
3/5
2970 0005 06
Registration code
Collection : APC ZD 2800 VSD
Tab : 15
1901 0625 92
Ed. : 07
date 25-Mar-11
ZD : ZD 2800 VSD
AML : Principal data
ZD type : ZD 2800 VSD
ZR type : ZR315 VSD-10,4 FF
D type : DN250VSD-10,4
4 Compressed air temperature at high pressure stage outlet
at reference conditions 30B 40B 30B 40B °C 74 93
at effective motor speeds ZR at 1407 1347 rpm D at 595 595 rpm °C 70 89
1585 1525 rpm 687 693 rpm °C 70 89
1763 1703 rpm 778 790 rpm °C 71 90
1941 1881 rpm 868 885 rpm °C 72 91
2120 2060 rpm 957 979 rpm °C 73 92
2298 2238 rpm 1043 1071 rpm °C 74 93
2476 2416 rpm 1129 1162 rpm °C 75 94
2654 2594 rpm 1213 1251 rpm °C 76 95
2832 2772 rpm 1296 1339 rpm °C 77 96
2951 2951 rpm 1350 1426 rpm °C 77 96
5 Compressed air temperature at outlet flange °C 30
6 Cooling water consumption corresponding to a water temperature rise of 15°C (8) l/s 8.4
7 Pressure drop over the cooling water system for the water consumption stated in 6 bar 1,0
8 Sound pressure level (with canopies) (9) dB (A) 83.9
9 Pressure dew point °C 3
Design data compressor
1 Number of compression stages 4
2.1 ZR male rotor speed at minimum speed
LH stage rpm 4835
HP stage rpm 7251
ZR male rotor speed at maximum speed
LH stage rpm 10887
HP stage rpm 16331
2.2 ZR - Displacement
at reference conditions (2238 r/min) l/s 684
at maximum speed (2951 r/min) l/s 902
3.1 D - Speed
minimum speed rpm 400
maximum speed rpm 959
3.2 D - stroke mm 130
3.3 D - piston speed
minimum speed m/s 1.73
maximum speed m/s 4.16
3.4 D - Displacement (LP / HP stage)
minimum speed l/s 48 / 24
maximum speed l/s 115 / 57
4 D - Oil capacity l 35
2970 0005 07
4/5
2970 0005 06
Registration code
Collection : APC ZD 2800 VSD
Tab : 15
1901 0625 92
Ed. : 07
date 25-Mar-11
ZD : ZD 2800 VSD
AML : Principal data
ZD type : ZD 2800 VSD
ZR type : ZR315 VSD-10,4 FF
D type : DN250VSD-10,4
Design data unit
1 ZR - Drive motor type (10) ABB
2 D - Drive motor type (10) ABB
3 ZR - Converter type ABB
ACS800-04
4 D - Converter type ABB
ACS800-04M-0320-5
5 D - Fan motor type (for canopy version only) Siemens
1LA5 090
6 ZD - Total cooling air flow at inlet gratings (11) m3/s 4.03
7 ZR - dimensions without packing (approx.)
length m 4.34
width m 1.65
height m 2.00
8 D - dimensions without packing (approx.)
length m 3.70
width m 2.48
height m 2.13
9 ZR - mass kg 6080
10 MD - mass kg integrated in ZR
11 D - mass (with canopy) kg 16800
12 D - specific load daN/m² 2089
13 Global dimensions (see installation drawing)
(1) at max elevation = 1000m
(2) continuous operation of the unit at an effective working pressure below 30bar (g) might reduce the lifetime of the discharge valves
of the booster second stage.
(3) for customer cooling circuit. If cooling system supplied by Atlas Copco, please contact Atlas Copco
(4) At reference conditions, unless otherwise stated and according to ISO 1217.
(5) Corresponds to 'Actual Volume Flow Rate' (ISO 1217). Tolerance +/- 4%
(6) Tolerance +/- 20%
(7) Supply voltage 400V for 50Hz units, 440/460V for 60Hz units
(8) with 30% glycol in water
(9) A-weighted sound pressure level LpA, sound power level LwA, uncertainty +3dB, reference 20 µPa, according to ISO 3746
(10) ZD VSD not supplied without motor
(11) At reference conditions and 10°C indoor canopies temperature increase