This document provides the drawing index for construction documents for the Rose-Hulman Institute of Technology Moench Hall Renovation project in Terre Haute, Indiana. The drawing index lists over 30 drawings organized by discipline including general, structural, fire protection, mechanical, electrical, and telecommunications. It also includes 3 general project notes that specify the contractor's responsibility to review and coordinate the work of all subcontractors and trades and make them aware of all contract requirements.

Uploaded by

Rohan Dutt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
237 views99 pages

Drawings Volume 1

This document provides the drawing index for construction documents for the Rose-Hulman Institute of Technology Moench Hall Renovation project in Terre Haute, Indiana. The drawing index lists over 30 drawings organized by discipline including general, structural, fire protection, mechanical, electrical, and telecommunications. It also includes 3 general project notes that specify the contractor's responsibility to review and coordinate the work of all subcontractors and trades and make them aware of all contract requirements.

Uploaded by

Rohan Dutt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

VOLUME

1
RHIT MOENCH RENOVATION

SET NO.
Terre Haute, Indiana

04/01/21
DATE

Construction Documents
PACKAGE
RATIO PROJECT NO.

19010.000
SEAL | DATE 04/01/21
PACKAGE

Construction Documents
OWNER ARCHITECT VOLUME
Rose-Hulman Institute of RATIO 1
Technology 101 South Pennsylvania Street
Indianapolis, Indiana 46204
5500 Wabash Avenue (317) 633-4040
Terre Haute, Indiana 47803 RATIO PROJECT NO.

RHIT MOENCH RENOVATION


(812)877-1511 STRUCTURAL ENGINEER
19010.000
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
(317)-600-4545 OWNER PROJECT NO.

MECHANICAL / ELECTRICAL ENGINEER

R.E. Dimond and Associates, Inc.


732 North Capitol Avenue DATE

PROJECT NAME
Indianapolis, Indiana 46204
(317)-634-4672 04/01/21

PROJECT ADDRESS

5500 Wabash Avenue


Terre Haute, Indiana 47803
DRAWING INDEX
Sheet # Sheet Name Sheet # Sheet Name Sheet # Sheet Name Sheet # Sheet Name GENERAL PROJECT NOTES

GENERAL FD-204.2 SECOND LEVEL - AREA 2 - FIRE PROTECTION DEMOLITION M-702 CONTROLS - MISCELLANEOUS T-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - TELECOM.
A. THE FOLLOWING GENERAL NOTES APPLY TO THESE
CONTRACT DOCUMENTS AND ARE NOT SPECIFIC TO ANY
RHIT MOENCH
RENOVATION
ONE DISCIPLINE.
G-002 SHEET INDEX AND PROJECT LOCATION FP-101 OVERALL LOWER LEVEL 2 - FIRE PROTECTION M-703 CONTROL SEQUENCES - AIR HANDLING UNITS (AHU) T-203.1 FIRST LEVEL - AREA 1 - TELECOM. B. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND
G-003 LIFE SAFETY PLANS AND CODE SUMMARY FP-102 OVERALL LOWER LEVEL1 - FIRE PROTECTION T-203.2 FIRST LEVEL - AREA 2 - TELECOM. COORDINATE THE WORK OF ALL SUB-CONTRACTORS,
TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE

STRUCTURAL
FP-103
FP-104
OVERALL FIRST LEVEL - FIRE PROTECTION
OVERALL SECOND LEVEL - FIRE PROTECTION
ELECTRICAL
E-001 SYMBOLS, ABBREVIATIONS, & GENERAL NOTES - ELECTRICAL
T-203.3
T-204.1
CRAPO LEVEL 3 - AREA 3 (L1) - TELECOM.
SECOND LEVEL - AREA 1 - TELECOM.
CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO
ASSURE THAT ALL PARTIES ARE AWARE OF ALL
5500 Wabash Avenue
S-001 GENERAL NOTES FP-201.1 LOWER LEVEL 2 - AREA 1 - FIRE PROTECTION ED-201.1 LOWER LEVEL 2 - AREA 1 - ELECTRICAL DEMOLITION T-204.2 SECOND LEVEL - AREA 2 - TELECOM.
REQUIREMENTS, REGARDLESS OF WHERE THE
REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS,
WHICH MIGHT AFFECT THE WORK OF THAT PARTY.
Terre Haute, Indiana
S-002 GENERAL NOTES FP-201.2 LOWER LEVEL 2 - AREA 2 - FIRE PROTECTION ED-201.2 LOWER LEVEL 2 - AREA 2 - ELECTRICAL DEMOLITION T-301 ENLARGED PLANS - TECHNOLOGY
S-003 DESIGN INFORMATION FP-202.1 LOWER LEVEL 1 - AREA 1 - FIRE PROTECTION ED-201.3 CRAPO LEVEL 1 - AREA 3 (LL2) - ELECTRICAL DEMOLITION T-302 BUILDING SECTION - TELECOM.
C. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND
SHOULD NOT BE DISTRIBUTED OR UTILIZED BY THE 47803
CONTRACTOR.
SD-112 LOWER LEVEL 1 DEMOLITION PLAN FP-202.2 LOWER LEVEL 1 - AREA 2 - FIRE PROTECTION ED-202.1 LOWER LEVEL 1- AREA 1 - ELECTRICAL DEMOLITION T-401 DETAILS - TELECOM. BONDING AND GROUNDING D. THE CONSTRUCTION DOCUMENTS ESTABLISH DETAILED Owner
SD-113 FIRST LEVEL DEMOLITION PLAN FP-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - FIRE PROTECTION ED-202.2 LOWER LEVEL 1 - AREA 2 - ELECTRICAL DEMOLITION T-402 DETAILS - PHYSICAL SECURITY MINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE
Rose-Hulman Institute of Technology
PROJECT.
SD-114 SECOND LEVEL DEMOLITION PLAN FP-203.1 FIRST LEVEL - AREA 1 - FIRE PROTECTION ED-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - ELECTRICAL DEMOLITION T-403 DETAILS - TELECOM. BACKBONE AND ROUGH-INS E. THE GENERAL NOTES, SYMBOLS AND DEFINITIONS 5500 Wabash Avenue
SD-115 ROOF DEMOLITION PLAN FP-203.2 FIRST LEVEL - AREA 2 - FIRE PROTECTION ED-203.1 FIRST LEVEL - AREA 1 - ELECTRICAL DEMOLITION T-404 IDENTIFICATION DETAILS - TELECOM. APPLICABLE ONLY TO EACH DISCIPLINE CAN BE FOUND AT Terre Haute, Indiana 47803
THE FRONT OF EACH DISCIPLINES PORTION OF THE SET OF 812-877-1511
SD-200 ENLARGED DEMOLITION PLANS FP-203.3 CRAPO LEVEL 3 - AREA 3 (L1) - FIRE PROTECTION ED-203.2 FIRST LEVEL - AREA 2 - ELECTRICAL DEMOLITION DRAWINGS AND IS LISTED AS PART OF THE OVERALL
PROJECT INDEX OF DRAWINGS. ▐►VERIFY◄▌
SD-500 STRUCTURAL DEMOLITION ELEV, SECTIONS AND DETAILS FP-204.1 SECOND LEVEL - AREA 1 - FIRE PROTECTION ED-203.3 CRAPO LEVEL 3 - AREA 3 (L1) - ELECTRICAL DEMOLITION F. BASIC FIRE PROTECTION AND THE EXITING SCHEME ARE
S-102 LOWER LEVEL 1 FLOOR PLAN FP-204.2 SECOND LEVEL - AREA 2 - FIRE PROTECTION ED-204.1 SECOND LEVEL - AREA 1 - ELECTRICAL DEMOLITION ILLUSTRATED BY THE EGRESS PLAN(S) AND APPLICABLE
FIRE AND BUILDING CODE SUMMARY ON SHEET ▐►G-002◄▌
S-102.3 LOWER LEVEL 1 FLOOR PLAN - AREA 3 FP-204.3 SKYLIGHT LEVEL - AREAS 1 & 2 - FIRE PROTECTION ED-204.2 SECOND LEVEL - AREA 2 - ELECTRICAL DEMOLITION G. THE ARCHITECTURAL DRAWINGS ESTABLISH, COORDINATE
S-103 FIRST LEVEL FLOOR PLAN ALTERNATE ED-220.1 ROOF - AREA 1 - ELECTRICAL DEMOLITION AS WELL AS TAKE PRECEDENCE FOR THE FINISH
APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK OF
S-103.1 FIRST LEVEL FLOOR PLAN - AREA 1 FP-205 ATTIC LEVEL - AREA 1 - FIRE PROTECTION ED-220.2 ROOF - AREA 2 - ELECTRICAL DEMOLITION ALL TRADES INCLUDING THAT WORK WHICH IS ILLUSTRATED
S-103.2 FIRST LEVEL FLOOR PLAN - AREA 2 FP-501 FIRE RISER DIAGRAM ED-231.1 LOWER LEVEL 2 - AREA 1 - FIRE ALARM DEMOLITION PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES.
H. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR
S-104 SECOND LEVEL FLOOR PLAN ED-231.2 LOWER LEVEL 2 - AREA 2 - FIRE ALARM DEMOLITION ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF Architect
PLUMBING THE CONTRACT. THESE NOT IN CONTRACT ITEMS ARE
S-104.1 SECOND LEVEL FLOOR PLAN - AREA 1 ED-231.3 CRAPO LEVEL 1 - AREA 3 (LL2) - FIRE ALARM DEMOLITION REFERENCED AND/OR ILLUSTRATED FOR THE RATIO
S-104.2 SECOND LEVEL FLOOR PLAN - AREA 2 PD-201.1 LOWER LEVEL 2 - AREA 1 - PLUMBING DEMOLITION ED-232.1 LOWER LEVEL 1 - AREA 1 - FIRE ALARM DEMOLITION CONTRACTORS REFERENCE, INFORMATION AND 101 South Pennsylvania Street
COORDINATION ONLY. Indianapolis, Indiana 46204
S-105 ROOF FRAMING PLAN PD-201.2 LOWER LEVEL 2 - AREA 2 - PLUMBING DEMOLITION ED-232.2 LOWER LEVEL 1 - AREA 2 - FIRE ALARM DEMOLITION I. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH
317-633-4040
S-200 ENLARGED PLANS PD-201.3 CRAPO LEVEL 1 - AREA 3 (LL2) - PLUMBING DEMOLITION ED-232.3 CRAPO LEVEL 2 - AREA 3 (LL1) - FIRE ALARM DEMOLITION APPLICABLE LAWS, CODES, REGULATIONS AND ORDINANCES
OF THE PLACE (CITY, COUNTY, DISTRICT AND STATE) WHERE
S-500 TYPICAL STRUCTURAL STEEL DETAILS PD-202.1 LOWER LEVEL 1 - AREA 1 - PLUMBING DEMOLITION ED-233.1 FIRST LEVEL - AREA 1 - FIRE ALARM DEMOLITION THE PROJECT IS LOCATED - ALTHOUGH SUCH
REQUIREMENTS MAY NOT BE REFLECTED BY THESE Structural Engineer
S-501 STRUCTURAL STEEL SECTIONS AND DETAILS PD-202.2 LOWER LEVEL 1 - AREA 2 - PLUMBING DEMOLITION ED-233.2 FIRST LEVEL - AREA 2 - FIRE ALARM DEMOLITION CONTRACT DOCUMENTS. Fink Roberts & Petrie, Inc.
S-502 STRUCTURAL STEEL SECTIONS AND DETAILS PD-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - PLUMBING DEMOLITION ED-233.3 CRAPO LEVEL 3 - AREA 3 (L1) - FIRE ALARM DEMOLITION J. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE
RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE 9449 Priority Way W Dr #200
S-503 STRUCTURAL STEEL SECTIONS AND DETAILS PD-203.1 FIRST LEVEL - AREA 1 - PLUMBING DEMOLITION ED-234.1 SECOND LEVEL - AREA 1 - FIRE ALARM DEMOLITION CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS Indianapolis, Indiana 46240
PD-203.2 FIRST LEVEL - AREA 2 - PLUMBING DEMOLITION ED-234.2 SECOND LEVEL - AREA 2 - FIRE ALARM DEMOLITION AT THE SITE PRIOR TO SUBMITTING A BID. THE CONTRACTOR 317-872-8400
SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
ARCHITECTURAL PD-204.1 SECOND LEVEL - AREA 1 - PLUMBING DEMOLITION ED-501 RISER DIAGRAM - MAIN DISTRIBUTION & 480V ELECTRICAL K. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS
A-001 GENERAL NOTES, SYMBOLS, AND STANDARD MOUNTING PD-204.2 SECOND LEVEL - AREA 2 - PLUMBING DEMOLITION DEMOLITION AND SIMILAR RELEASES REQUIRED FOR THE
Mechanical / Electrical Engineer
CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE
HEIGHTS PD-205.1 ATTIC LEVEL - AREA 1 - PLUMBING DEMOLITION ED-502 ELEVATIONS - WIREWAY DEMOLITION CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS R.E. Dimond & Associates, Inc.
TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF
A-002 INTERIOR PARTITION TYPES AND STANDARD PARTITION PD-220.1 ROOF - AREA 1 - PLUMBING DEMOLITION E-201.1 LOWER LEVEL 2 - AREA 1 - LIGHTING RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT 732 N Capitol Avenue
DETAILS PD-220.2 ROOF - AREA 2 - PLUMBING DEMOLITION E-201.2 LOWER LEVEL 2 - AREA 2 - LIGHTING TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF Indianapolis, Indiana 46204
AE-101 LOWER LEVEL 2 EXISTING PLAN PERMITS ARE DELAYED FOR ANY REASON, THE 317-634-4672
P-100.2 UNDERSLAB - AREA 2 - PLUMBING E-201.3 CRAPO LEVEL 1 - AREA 3 (LL2) - LIGHTING CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT.
AE-102 LOWER LEVEL 1 EXISTING PLAN P-201.1 LOWER LEVEL 2 - AREA 1 - PLUMBING E-202.1 LOWER LEVEL 1 - AREA 1 - LIGHTING L. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN
AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS
AE-103 FIRST LEVEL EXISTING PLAN P-201.2 LOWER LEVEL 2 - AREA 2 - PLUMBING E-202.2 LOWER LEVEL 1 - AREA 2 - LIGHTING AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO
AE-104 SECOND LEVEL EXISTING PLAN P-202.1 LOWER LEVEL 1 - AREA 1 - PLUMBING E-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - LIGHTING SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY
REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT.
AD-111 LOWER LEVEL 2 DEMOLITION PLAN P-202.2 LOWER LEVEL 1 - AREA 2 - PLUMBING E-203.1 FIRST LEVEL - AREA 1 - LIGHTING IF SATISFACTORY REPAIRS CANNOT BE MADE, THE
AD-112 LOWER LEVEL 1 DEMOLITION PLAN CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS
P-203.1 FIRST LEVEL - AREA 1 - PLUMBING E-203.2 FIRST LEVEL - AREA 2 - LIGHTING WITH LIKE NEW QUALITY ACCEPTABLE TO THE ARCHITECT.
AD-113 FIRST LEVEL DEMOLITION PLAN P-203.2 FIRST LEVEL - AREA 2 - PLUMBING E-203.3 CRAPO LEVEL 3 - AREA 3 (L1) - LIGHTING ALL REPAIRS AND REPLACEMENT COST SHALL BE THE
FINANCIAL RESPONSIBILITY OF THE CONTRACTOR.
AD-114 SECOND LEVEL DEMOLITION PLAN P-204.1 SECOND LEVEL - AREA 1 - PLUMBING E-204.1 SECOND LEVEL - AREA 1 - LIGHTING
AD-115 ROOF DEMOLITION PLAN P-204.2 SECOND LEVEL - AREA 2 - PLUMBING E-204.2 SECOND LEVEL - AREA 2 - LIGHTING REV. 03/31/09
AD-201 EXTERIOR DEMO ELEVATIONS P-205.1 ATTIC LEVEL - AREA 1 - PLUMBING E-211.1 LOWER LEVEL 2 - AREA 1 - POWER
A-101 LOWER LEVEL 2 OVERALL FLOOR PLAN P-220.1 ROOF - AREA 1 - PLUMBING E-211.2 LOWER LEVEL 2 - AREA 2 - POWER
A-101.1 LOWER LEVEL 2 FLOOR PLAN - AREA 1 P-220.2 ROOF - AREA 2 - PLUMBING E-211.3 CRAPO LEVEL 1 - AREA 3 (LL2) - POWER
A-101.2 LOWER LEVEL 2 FLOOR PLAN - AREA 2 P-301 ENLARGED PLANS - PLUMBING E-212.1 LOWER LEVEL 1 - AREA 1 - POWER
A-102 LOWER LEVEL 1 OVERALL FLOOR PLAN P-401 DETAILS - PLUMBING E-212.2 LOWER LEVEL 1 - AREA 2 - POWER
A-102.1 LOWER LEVEL 1 FLOOR PLAN - AREA 1 P-601 SCHEDULES - PLUMBING E-212.3 CRAPO LEVEL 2 - AREA 3 (LL1) - POWER
A-102.2 LOWER LEVEL 1 FLOOR PLAN - AREA 2 E-213.1 FIRST LEVEL - AREA 1 - POWER
A-102.3 CRAPO LEVEL 2 FLOOR PLAN - AREA 3 (LL1) MECHANICAL E-213.2 FIRST LEVEL - AREA 2 - POWER
A-103 FIRST LEVEL OVERALL FLOOR PLAN PM-001 SYMBOLS, ABBREVIATIONS, & GENERAL NOTES - MECHANICAL E-213.3 CRAPO LEVEL 3 - AREA 3 (L1) - POWER
A-103.1 FIRST LEVEL FLOOR PLAN - AREA 1 MD-201.1 LOWER LEVEL 2 - AREA 1 - MECHANICAL DEMOLITION E-214.1 SECOND LEVEL - AREA 1 - POWER
A-103.2 FIRST LEVEL FLOOR PLAN - AREA 2 MD-201.2 LOWER LEVEL 2 - AREA 2 - MECHANICAL DEMOLITION E-214.2 SECOND LEVEL - AREA 2 - POWER
A-103.3 CRAPO LEVEL 3 FLOOR PLAN - AREA 3 (L1) MD-202.1 LOWER LEVEL 1 - AREA 1 - MECHANICAL DEMOLITION E-220.1 ROOF - AREA 1 - ELECTRICAL
A-104 SECOND LEVEL OVERALL FLOOR PLAN MD-202.2 LOWER LEVEL 1 - AREA 2 - MECHANICAL DEMOLITION E-220.2 ROOF - AREA 2 - ELECTRICAL
A-104.1 SECOND LEVEL FLOOR PLAN - AREA 1 MD-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - MECHANICAL DEMOLITION E-231.1 LOWER LEVEL 2 - AREA 1 - FIRE ALARM
A-104.2 SECOND LEVEL FLOOR PLAN - AREA 2 MD-203.1 FIRST LEVEL - AREA 1 - MECHANICAL DEMOLITION E-231.2 LOWER LEVEL 2 - AREA 2 - FIRE ALARM REGION MAP
A-105 ROOF PLAN - OVERALL MD-203.2 FIRST LEVEL - AREA 2 - MECHANICAL DEMOLITION E-231.3 CRAPO LEVEL 1 - AREA 3 (LL2) - FIRE ALARM
A-105.1 SKYLIGHT PLAN MD-203.3 CRAPO LEVEL 1 - AREA 3 (L1) - MECHANICAL DEMOLITION E-232.1 LOWER LEVEL 1 - AREA 1 - FIRE ALARM
A-131.1 LOWER LEVEL 2 REFLECTED CEILING PLAN - AREA 1 MD-204.1 SECOND LEVEL - AREA 1 - MECHANICAL DEMOLITION E-232.2 LOWER LEVEL 1 - AREA 2 - FIRE ALARM
A-131.2 LOWER LEVEL 2 REFLECTED CEILING PLAN - AREA 2 MD-204.2 SECOND LEVEL - AREA 2 - MECHANICAL DEMOLITION E-232.3 CRAPO LEVEL 2 - AREA 3 (LL1) - FIRE ALARM
A-132.1 LOWER LEVEL 1 REFLECTED CEILING PLAN - AREA 1 MD-205.1 ATTIC LEVEL - AREA 1 MECHANICAL DEMOLITION E-233.1 FIRST LEVEL - AREA 1 - FIRE ALARM
A-132.2 LOWER LEVEL 1 REFLECTED CEILING PLAN - AREA 2 MD-220.1 ROOF - AREA 1 - MECHANICAL DEMOLITION E-233.2 FIRST LEVEL - AREA 2 - FIRE ALARM
A-132.3 LOWER LEVEL 1 REFLECTED CEILING PLAN - AREA 3 MD-220.2 ROOF - AREA 2 - MECHANICAL DEMOLITION E-233.3 CRAPO LEVEL 3 - AREA 3 (L1) - FIRE ALARM
A-133.1 FIRST LEVEL REFLECTED CEILING PLAN - AREA 1 M-201.1 LOWER LEVEL 2 - AREA 1 - AIR DISTRIBUTION E-234.1 SECOND LEVEL - AREA 1 - FIRE ALARM
A-133.2 FIRST LEVEL REFLECTED CEILING PLAN - AREA 2 M-201.2 LOWER LEVEL 2 - AREA 2 - AIR DISTRIBUTION E-234.2 SECOND LEVEL - AREA 2 - FIRE ALARM
A-133.3 FIRST LEVEL REFLECTED CEILING PLAN - AREA 3 M-202.1 LOWER LEVEL 1 - AREA 1 - AIR DISTRIBUTION E-235.1 ATTIC LEVEL - AREA 1 - FIRE ALARM
A-134.1 SECOND LEVEL REFLECTED CEILING PLAN - AREA 1 M-202.2 LOWER LEVEL 1 - AREA 2 - AIR DISTRIBUTION E-310 LOWER LEVEL 2 BOILER ROOM UNIT F - ELECTRICAL SEAL | DATE 04/01/21
A-134.2 SECOND LEVEL REFLECTED CEILING PLAN - AREA 2 M-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - AIR DISTRIBUTION E-401 DETAILS - GROUNDING PROJECT
LOCATION
A-152.2 LOWER LEVEL 1 FINISH PLAN - AREA 2 M-203.1 FIRST LEVEL - AREA 1 - AIR DISTRIBUTION E-402 DETAILS - LIGHTING
A-152.3 LOWER LEVEL 1 FINISH PLAN - AREA 3 M-203.2 FIRST LEVEL - AREA 2 - AIR DISTRIBUTION E-403 DETAILS - ELECTRICAL
A-153.2 FIRST LEVEL FINISH PLAN - AREA 2 M-203.3 CRAPO LEVEL 3 - AREA 3 (L1) - AIR DISTRIBUTION E-404 DETAILS - ELECTRICAL
A-153.3 FIRST LEVEL FINISH PLAN - AREA 3 M-204.1 SECOND LEVEL - AREA 1 - AIR DISTRIBUTION E-501 RISER DIAGRAM - MAIN DISTRIBUTION & 480V ELECTRICAL
A-154.1 SECOND LEVEL FINISH PLAN - AREA 1 M-204.2 SECOND LEVEL - AREA 2 - AIR DISTRIBUTION E-502 RISER DIAGRAM - 208V ELECTRICAL
A-154.2 SECOND LEVEL FINISH PLAN - AREA 2 M-205.1 ATTIC LEVEL - AREA 1 - AIR DISTRIBUTION E-503 RISER DIAGRAM - EMERGENCY ELECTRICAL
A-172 LOWER LEVEL 1 FURNITURE PLAN M-211.1 LOWER LEVEL 2 - AREA 1 - HYDRONICS E-504 RISER DIAGRAM - CRAPO HALL
A-173 FIRST LEVEL FURNITURE PLAN M-211.2 LOWER LEVEL 2 - AREA 2 - HYDRONICS E-505 TRANSFORMER SCHEDULE
A-174 SECOND LEVEL FURNITURE PLAN M-212.1 LOWER LEVEL 1 - AREA 1 - HYDRONICS E-506 ELEC. PANELBOARD INTERIOR RETROFIT SCHEDULE SHEET ISSUE
A-201 EXTERIOR ELEVATIONS M-212.2 LOWER LEVEL 1 - AREA 2 - HYDRONICS E-601 SCHEDULES - LIGHTING 1 Construction Documents 04/01/21
A-202 EXTERIOR ELEVATIONS M-212.3 CRAPO LEVEL 2 - AREA 3 (LL1) - HYDRONICS E-611 SCHEDULES - PANELBOARDS - MAIN DISTRIBUTION
A-301 BUILDING SECTIONS M-213.1 FIRST LEVEL - AREA 1 - HYDRONICS E-612 SCHEDULES - PANELBOARDS - EMERGENCY
A-321 ROOF MONITOR SECTIONS M-213.2 FIRST LEVEL - AREA 2 - HYDRONICS E-613 SCHEDULES - PANELBOARDS - EMERGENCY
A-322 ROOF MONITOR SECTIONS M-213.3 CRAPO LEVEL 3 - AREA 3 (L1) - HYDRONICS E-614 SCHEDULES - PANELBOARDS - AREA A
A-350 EXTERIOR DETAILS M-214.1 SECOND LEVEL - AREA 1 - HYDRONICS E-615 SCHEDULES - PANELBOARDS - AREA B
A-351 EXTERIOR DETAILS M-214.2 SECOND LEVEL - AREA 2 - HYDRONICS E-616 SCHEDULES - PANELBOARDS - AREA B
A-401 ENLARGED PLANS M-220.1 ROOF - AREA 1 - AIR DISTRIBUTION E-617 SCHEDULES - PANELBOARDS - AREA C
A-402 CAFE M-220.2 ROOF - AREA 2 - AIR DISTRIBUTION E-618 SCHEDULES - PANELBOARDS - AREA C PROJECT LOCATION
A-403 CAFE M-301 ATTIC MECHANICAL ROOM UNIT A (AHU-1) E-619 SCHEDULES - PANELBOARDS - AREA D
A-404 LIVING WALL M-302 MECHANICAL ROOM B207 (AHU-3) E-620 SCHEDULES - PANELBOARDS - AREA D
A-421 STAIR AND RAMP PLANS AND SECTIONS M-303 MECHANICAL ROOM C201 (AHU-5) E-621 SCHEDULES - PANELBOARDS - AREA E
A-422 STAIR AND RAMP PLANS, SECTIONS, AND DETAILS M-304 MECHANICAL ROOM C218 (AHU-6) E-622 SCHEDULES - PANELBOARDS - AREA E
A-423 STAIR AND RAMP DETAILS M-305 MECHANICAL ROOM C214 (AHU-7) E-623 SCHEDULES - PANELBOARDS - AREA F
A-501 INTERIOR ELEVATIONS M-306 MECHANICAL ROOM C215 (AHU-8) E-624 SCHEDULES - PANELBOARDS - TELECOM B107A
A-502 INTERIOR ELEVATIONS M-307 MECHANICAL ROOM E201 (AHU-9) E-625 SCHEDULES - PANELBOARDS - CRAPO
A-530 MILLWORK DETAILS M-308 MECHANICAL ROOM G116 (AHU-10)
A-531 MILLWORK DETAILS M-309 MECHANICAL ROOM FL201 (AHU-11 E.) TELECOMMUNICATIONS PROJECT
A-532 PLAN DETAILS M-310 SECOND LEVEL - CENTRAL MONITOR - AIR DISTRIBUTION T-001 SYMBOLS, ABBREVIATIONS, & GENERAL NOTES - TELECOM. LOCATION
A-540 CEILING DETAILS M-311 SECOND LEVEL - CENTRAL MONITOR - HYDRONICS TD-201.1 LOWER LEVEL 2 - AREA 1 - TELECOM. DEMOLITION
A-601 DOOR SCHEDULE M-321 SECTIONS - MECHANICAL TD-201.2 LOWER LEVEL 2 - AREA 2 - TELECOM. DEMOLITION
A-602 DOOR DETAILS M-322 SECTIONS - MECHANICAL TD-201.3 CRAPO LEVEL 1 - AREA 3 (LL2) - TELECOM. DEMOLITION
A-621 WINDOW ELEVATIONS AND DETAILS M-323 SECTIONS - MECHANICAL TD-202.1 LOWER LEVEL 1 - AREA 1 - TELECOM. DEMOLITION COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
A-622 EXTERIOR WINDOW ELEVATIONS AND DETAILS M-324 SECTIONS - MECHANICAL TD-202.2 LOWER LEVEL 1 - AREA 2 - TELECOM. DEMOLITION AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A-650 FINISH SCHEDULE AND FINISH DETAILS M-401 DETAILS - AIR DISTRIBUTION TD-202.3 CRAPO LEVEL 2 - AREA 3 (LL1) - TELECOM. DEMOLITION
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

A-901 3D ROOF AXONS M-402 DETAILS - AIR DISTRIBUTION TD-203.1 FIRST LEVEL - AREA 1 - TELECOM. DEMOLITION PROJECT NO. 19010.000
M-411 DETAILS - HYDRONICS TD-203.2 FIRST LEVEL - AREA 2 - TELECOM. DEMOLITION SHEET TITLE
FIRE PROTECTION
FD-201.1 LOWER LEVEL 2 - AREA 1 - FIRE PROTECTION DEMOLITION
M-412
M-415
DETAILS - HYDRONICS
AHU - PROFILES
TD-203.3
TD-204.1
CRAPO LEVEL 3 - AREA 3 (L1) - TELECOM. DEMOLITION
SECOND LEVEL - AREA 1 - TELECOM. DEMOLITION
SHEET INDEX AND
FD-201.2 LOWER LEVEL 2 - AREA 2 - FIRE PROTECTION DEMOLITION M-416 AHU - PROFILES TD-204.2 SECOND LEVEL - AREA 2 - TELECOM. DEMOLITION PROJECT LOCATION
FD-202.1 LOWER LEVEL 1 - AREA 1 - FIRE PROTECTION DEMOLITION M-417 AHU - PROFILES T-201.1 LOWER LEVEL 2 - AREA 1 - TELECOM.
FD-202.2 LOWER LEVEL 1 - AREA 2 - FIRE PROTECTION DEMOLITION M-601 SCHEDULES - AIR DISTRIBUTION T-201.2 LOWER LEVEL 2 - AREA 2 - TELECOM.
4/1/2021 12:32:11 PM

FD-203.1 FIRST LEVEL - AREA 1 - FIRE PROTECTION DEMOLITION M-602 SCHEDULES - AIR DISTRIBUTION T-201.3 CRAPO LEVEL 1 - AREA 3 (LL2) - TELECOM.
FD-203.2 FIRST LEVEL - AREA 2 - FIRE PROTECTION DEMOLITION M-611 SCHEDULES - HYDRONICS T-202.1 LOWER LEVEL 1 - AREA 1 - TELECOM.
FD-204.1 SECOND LEVEL - AREA 1 - FIRE PROTECTION DEMOLITION SHEET NUMBER
M-701 CONTROLS - GENERAL T-202.2 LOWER LEVEL 1 - AREA 2 - TELECOM.

G-002
CODE SUMMARY GENERAL LIFE SAFETY PLAN NOTES
A. REFER TO SHEET G-003 FOR CODE SUMMARY.
B. REFER TO DOOR SCHEDULE FOR REQUIRED DOOR RATING.
RHIT MOENCH

2222222222222222

2222222222222222
C. REFER TO INTERIOR PARTITION TYPES AND FLOOR PLAN
FOR ADDITIONAL PARTITION REQUIREMENTS INCLUDING
WALL HEIGHT, UL DESIGN, AND FIRE RATING.
D. REFER TO [site plan] FOR BUILDING ADJACENCIES AND
RENOVATION
PROPERTY LINES.
E. REFER TO [demolition plans, site plan, phasing drawings] FOR
5500 Wabash Avenue
TEMPORARY CONSTRUCTION REQUIREMENTS.
F. REFER TO FLOOR PLANS FOR FIRE EXTINGUISHER Terre Haute, Indiana

2222

2222
LOCATIONS.

333333333333333333333333333333333333333333333333 333333333333333333333333333333333333333333333333 REV. 03/17/2010 47803

DW
222 FEC 222 Owner
LIFE SAFETY PLAN LEGEND

22

22
22

22
222 222 Rose-Hulman Institute of Technology
5500 Wabash Avenue
RM NAME ROOM NAME, AREA & Terre Haute, Indiana 47803
2222 150 SF OCCUPANT CAPACITY 812-877-1511

22222
20
EXIT DIRECTION ARROW
3333333333333333333333333 3333333333333333333333333333333333333333333333 45 EXIT POPULATION
120 EXIT CAPACITY [POPULATION]

PATH OF TRAVEL

2 2 2 EXISTING FIRE WALL


RATING REQUIRED..30-MIN, 1-HR, Architect
2-HR, ETC.
RATIO
3S 3S 3S SMOKE BARRIER 101 South Pennsylvania Street
RATING IF REQUIRED..1-HR, 2-HR, ETC. Indianapolis, Indiana 46204
317-633-4040
1 1 1 EXISTING FIRE WALL
PATTERN INDICATES CODE REQUIRED
SEPARATION AS NOTED Structural Engineer
FIRE BA.... FIRE SEPARATION AND OTHER Fink Roberts & Petrie, Inc.
ANNOTATION SO NOTED 9449 Priority Way W Dr #200
2222222

22
Indianapolis, Indiana 46240
2222222 FIRE RATED CEILING. RATING AS
1-HR NOTED...1-HR, 2-HR, ETC. 317-872-8400

DN
Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
OCCUPANT LOAD SCHEDULE 732 N Capitol Avenue
Indianapolis, Indiana 46204
FLOOR LEVEL OCCUPANT LOAD 317-634-4672
LOWER LEVEL 2 200
LOWER LEVEL 350
550

TRAVEL DISTANCE SCHEDULE


22
EXIT ROUTE DISTANCE

22
22
22
TRAVEL DIST. A 112' - 0"
333333333333333
TRAVEL DIST. B 80' - 0"

D2 LOWER LEVEL 2 LIFE SAFETY PLAN TRAVEL DIST. C 40' - 6"

G-003
1/32" = 1'-0"

APPROVED VARIANCES
VARIANCE
NUMBER DESCRIPTION
13-xx-xx(a)
13-xx-xx(b)
13-xx-xx(c)
13-xx-xx(d)
13-xx-xx(e)
D4 LOWER LEVEL 1 LIFE SAFETY PLAN
G-003
1/32" = 1'-0"

11
11
2222

2222
333333333333333333333333333333333333333333333333 333333333333333333333333333333333333333333333333
SEAL | DATE 04/01/21
222 222
22

22
22

22
222 222

3333333333333333333333333333333333333333333333 3333333333333333333333333333333333333333333333

SHEET ISSUE
1 Construction Documents 04/01/21

TO48
TO48
TO48

22 22
22

22
22

22

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


22 22 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
333333333333333333333333333333333333333333333333 333333333333333333333333333333333333333333333333
PROJECT NO. 19010.000
SHEET TITLE

LIFE SAFETY PLANS


AND CODE
SUMMARY
4/1/2021 11:52:32 AM

SHEET NUMBER
A2 FIRST LEVEL LIFE SAFETY PLAN A4 SECOND LEVEL LIFE SAFETY PLAN
G-003
1/32" = 1'-0"
G-003
1/32" = 1'-0" G-003
1.0 GENERAL PROJECT INFORMATION 13. PRINCIPAL OPENING SIZES AND LOCATIONS ARE INDICATED ON THE STRUCTURAL 1.3 SUBMITTALS 1.5 DEMOLITION AND STRUCTURAL REINFORCEMENT:
DRAWINGS. ADDITIONAL SMALLER OPENINGS, BLOCK OUTS AND SLEEVES MAY BE
1. STRUCTURAL DRAWINGS ARE PART OF A SINGLE DOCUMENT ISSUE INCLUDING REQUIRED BY OTHER TRADES AND SHALL BE CONSTRUCTED USING THE CRITERIA 1. THE CONTRACTOR SHALL SUBMIT FOR STRUCTURAL ENGINEER'S REVIEW A 1. REFER TO "SD" DRAWINGS FOR STRUCTURAL DEMOLITION WORK.
MULTIPLE DISCIPLINES. STRUCTURAL DRAWINGS AND SPECIFICATIONS ARE FULLY INDICATED IN THE STRUCTURAL DOCUMENTS. IF NO DETAILS ARE APPLICABLE, SCHEDULE WHICH DETAILS THE ESTIMATED QUANTITY OF SHOP DRAWINGS FOR
COMPLIMENTARY AND SUPPLEMENTAL TO EACH OTHER AND SHALL BE TAKEN AS A SUBMIT PROPOSED METHOD TO THE STRUCTURAL ENGINEER FOR APPROVAL. EACH SUBMITTAL AND THE DATE SHOP DRAWINGS WILL BE RECEIVED BY THE 2. CONTRACTOR SHALL DOCUMENT EXISTING CRACKS AND STRUCTURAL DAMAGE
WHOLE. WHERE CONFLICTS OCCUR, STRICTER REQUIREMENTS APPLY.
STRUCTURAL WORK PERFORMED UNDER THESE DRAWINGS AND SPECIFICATIONS
SHALL BE COORDINATED WITH EACH INDIVIDUAL CONTRACTOR. SEE DIVISION 1 OF
14. THERE SHALL BE NO VERTICAL OR HORIZONTAL SLEEVES SET, OR HOLES CUT OR
DRILLED IN ANY BEAM OR COLUMN UNLESS IT IS SHOWN ON THE STRUCTURAL
STRUCTURAL ENGINEER. THE STRUCTURAL ENGINEER SHALL HAVE THE
OPPORTUNITY TO REVIEW THE PROPOSED SCHEDULE AND SUBMIT COMMENTS TO
THE CONTRACTOR. THE FINAL SHOP DRAWING SCHEDULE SHALL BE MUTUALLY 3.
PRIOR TO BEGINNING DEMOLITION WORK.

DIMENSIONED OPENINGS ON THE DEMOLITION PLANS SHALL BE SAWCUT AND


RHIT MOENCH
THE PROJECT MANUAL FOR DETAILED SUMMARY OF WORK AND SCOPE OF BID
PACKAGES.
15.
DRAWINGS OR APPROVED BY THE ARCHITECT AND STRUCTURAL ENGINEER.

MECHANICAL, ELECTRICAL, AND PLUMBING OPENINGS THROUGH CONCRETE 2.


AGREED UPON BY THE CONTRACTOR AND STRUCTURAL ENGINEER.

THE CONTRACTOR IS TO REVIEW EACH SUBMITTAL PRIOR TO FORWARDING TO


GROUND SMOOTH AS NECESSARY TO WITHIN NORMAL ACI FORMWORK
TOLERANCES FOR NEW CONSTRUCTION. RENOVATION
2. TYPICAL DETAIL SECTION CUTS ARE NOT NECESSARILY SHOWN AT EACH AND EVERY
APPLICABLE LOCATION ON THE PLANS AND ELEVATIONS. TYPICAL DETAIL TITLES
IMPLY THE INTENT OF APPLICABILITY. APPLY DETAILS, SECTIONS, AND NOTES ON THE
SLABS AND WALLS LARGER THAN 12 INCHES IN DIAMETER OR LENGTH, NOT
SHOWN ON THE STRUCTURAL DRAWINGS, MUST BE APPROVED BY THE
STRUCTURAL ENGINEER. OPENINGS 12 INCHES IN DIAMETER OR LESS SHALL
ARCHITECT AND STRUCTURAL ENGINEER. THE CONTRACTOR IS TO STAMP EACH
SUBMITTAL TO VERIFY THAT THE FOLLOWING IS ADDRESSED:
4. THE CONTRACTOR IS FULLY RESPONSIBLE FOR THE MEANS AND METHODS OF
DEMOLITION AND THE INTEGRITY AND STABILITY OF THE EXISTING STRUCTURE
DURING EACH STAGE OF DEMOLITION UNTIL THE FULL EXTENT OF THE
5500 Wabash Avenue
DRAWINGS WHERE CONDITIONS ARE SIMILAR TO THOSE INDICATED BY DETAIL,
DETAIL TITLE, OR NOTES.
HAVE AT LEAST 1’-0” CLEAR BETWEEN OPENINGS UNLESS APPROVED BY THE
STRUCTURAL ENGINEER.
A.
B.
THE SHOP DRAWINGS ARE REQUESTED BY THE STRUCTURAL ENGINEER.
THE SHOP DRAWINGS ARE BASED ON THE LATEST DESIGN AND CORRECT
REINFORCEMENT DEMOLITION WORK, AND NEW CONSTRUCTION WORK IS
COMPLETED.
Terre Haute, Indiana
VERSION OF THE DOCUMENTS.

3. CONTRACTOR SHALL REFER TO SEPARATE SETS OF REPRODUCED ORIGINAL


16. VERIFY DIMENSIONS AND LOCATIONS OF OPENINGS THROUGH CONCRETE SLABS
SHOWN ON THE STRUCTURAL DRAWINGS WITH MEP CONTRACTORS. PROVIDE
C. THE ARCHITECT'S AND STRUCTURAL ENGINEER'S COMMENTS FROM ANY
PREVIOUS SUBMITTALS ARE ADDRESSED.
5. THE CONTRACTOR SHALL DESIGN, PROVIDE AND INSTALL ANY TEMPORARY
SHORING AND/OR BRACING FOR PORTIONS OF THE EXISTING STRUCTURE WHICH
47803
CONSTRUCTION DRAWINGS AVAILABLE IN ELECTRONIC FORMAT FOR MORE DETAILED ONE SINGLE PENETRATION SUBMITTAL FOR EACH CONCRETE POUR D. THE WORK IS COORDINATED AMONG ALL CONSTRUCTION TRADES. REQUIRE COMPLETION OF AND/OR ATTACHMENT TO THE NEW STRUCTURE FOR
INFORMATION ON STRUCTURAL SYSTEMS FOR EXISTING BUILDINGS. INCORPORATING ALL TRADES IN ONE SUBMITTAL FOR REVIEW. E. COMPONENT ENGINEER'S PROFESSIONAL ENGINEERING STAMP AND Owner
STABILITY. CONTRACTOR SHALL RETAIN A PROFESSIONAL ENGINEER LICENSED IN
SIGNATURE IS INCLUDED FOR DELEGATED DESIGN COMPONENT THE STATE WHERE THE PROJECT IS LOCATED TO DESIGN SUCH SHORING. Rose-Hulman Institute of Technology
4. PORTIONS OF EXISTING STRUCTURAL SYSTEMS HAVE BEEN MODELED BASED ON THE 17. THE FOLLOWING CONNECTION COMPONENTS, TO BE EMBEDDED IN CONCRETE DRAWINGS. 5500 Wabash Avenue
ORIGINAL CONSTRUCTION DRAWINGS. INFORMATION SHOWN ON THE "SD" SERIES ARE DETAILED ON THE STRUCTURAL DRAWINGS. CONCRETE CONTRACTOR SHALL F. REVISIONS FROM PREVIOUS SUBMITTAL ARE CLEARLY IDENTIFIED. 6. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS TO ANY AND ALL STRUCTURAL
DRAWINGS IS PROVIDED FOR REFERENCE ONLY. CONTRACTOR SHALL REFER TO COORDINATE THE FURNISHING AND INSTALLATION OF THESE ITEMS WITH THE G. SUBMITTAL IS COMPLETE AND ALL SCOPE ASSIGNED TO THE
Terre Haute, Indiana 47803
ELEMENTS DAMAGED DURING THE DEMOLITION PROCESS WHICH ARE TO REMAIN
SEPARATE SETS OF ORIGINAL DRAWINGS FOR COMPLETE INFORMATION. RESPECTIVE SUBCONTRACTOR. SUBCONTRACTOR HAS BEEN COVERED. IN THE FINAL CONDITION. REPAIRS SHALL MADE TO THE COMPLETE SATISFACTION
812-877-1511
H. THE STRUCTURAL ENGINEER MAY RETURN, WITHOUT COMMENT, OF THE OWNER AND BE AT NO EXPENSE TO THE OWNER. ALL REPAIR WORK
5. EXISTING BUILDING DESCRIPTIONS: A. ANCHOR RODS FOR STRUCTURAL STEEL. SUBMITTALS WHICH THE CONTRACTOR HAS NOT STAMPED OR WHICH DO SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE
NOT MEET THE ABOVE REQUIREMENTS. THE STRUCTURAL ENGINEER'S WHERE THE PROJECT IS LOCATED AND SUBMITTED TO THE STRUCTURAL
A. FOR 1922 CONSTRUCTION REFER TO DRAWINGS TITLED NEW BUILDING FOR 18. WELDS OR CONNECTIONS FOR ANCHORING PIPE RAILING TO EMBEDDED PLATES REVIEW OF SUBMITTALS SHALL BE FOR GENERAL CONFORMANCE WITH ENGINEER FOR REVIEW AND APPROVAL PRIOR TO COMMENCING REPAIR WORK.
ROSE POLYTECHNIC INSTITUTE, DATED MAY, 1922. OR STEEL ARE TO BE DESIGNED BY THE PIPE RAILING CONTRACTOR. THE DESIGN INTENT. NO WORK SHALL BE STARTED WITHOUT SUCH
REVIEW. 7. EXISTING FRAMING IS INDICATED FOR REFERENCE ONLY AND IS TO BE FIELD
B. FOR 1983 AND 1985 CONSTRUCTION REFER TO DRAWINGS BY 19. PROVIDE SUPPORT FRAMING FOR MECHANICAL OPENINGS THROUGH ROOF I. THE FOLLOWING ITEMS REQUIRE SUBMITTALS TO BE SUBMITTED BY VERIFIED BY THE CONTRACTOR. THE EXACT EXTENT OF DEMOLITION SHALL BE
VICKREY/OVRESAT/AWSUMB ASSOCIATES INC., DATED MAY, 1983 AND JULY AREAS INDICATED BY STRUCTURAL DRAWINGS AS INDICATED IN TYPICAL ROOF CONTRACTOR WHOSE SCOPE INCLUDES LISTED ITEM FOR STRUCTURAL VERIFIED AT THE SITE. DETERMINE THE NATURE AND EXTENT OF DEMOLITION
1985. DECK OPENING DETAIL. REVIEW AS OUTLINED IN THE SPECIFICATIONS: THAT WILL BE NECESSARY BY COMPARING THE CONTRACT DOCUMENTS WITH THE
EXISTING CONSTRUCTION. IMMEDIATELY NOTIFY THE ARCHITECT, STRUCTURAL
20. SPRINKLER AND OTHER MEP SYSTEMS LINE SHALL BE HUNG FROM STRUCTURAL DIV DESCRIPTION ENGINEER, AND MEP ENGINEER OF ANY INCONSISTENCIES.
STEEL, STRUCTURAL JOISTS OR JOIST GIRDERS, NOT FROM ROOF DECK WITHOUT 03 CONCRETE REINFORCING PLACEMENT DRAWINGS Architect
CONCRETE SLAB ABOVE. 03 CONCRETE MIX DESIGNS 8. ELECTRONIC COPIES OF THE EXISTING DRAWINGS AND/OR AS-BUILTS AND/OR RATIO
1.1 CONTRACTOR RESPONSIBILITIES AND COORDINATION 03 COORDINATED DRAWINGS FOR ALL SLEEVES, SHOP DRAWINGS ARE AVAILABLE TO BIDDERS.
PENETRATIONS AND EMBEDS 101 South Pennsylvania Street
1. THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS FOR SUCCESSFUL 03 ANCHOR ROD LAYOUT 9. THE CONTRACTOR SHALL USE THE STRUCTURAL CONTRACT DOCUMENTS IN Indianapolis, Indiana 46204
COMPLETION OF THIS PROJECT INCLUDING ANY ADDITIONAL LABOR AND MATERIAL 03 CONCRETE CONSTRUCTION JOINT LAYOUT CONJUNCTION WITH THE DEMOLITION CONTRACT DRAWINGS FROM THE 317-633-4040
NOT SHOWN ON THE DOCUMENTS THAT IS REQUIRED FOR TEMPORARY STABILITY 1.2 PERFORMANCE SPECIFIED DELEGATED DESIGN COMPONENTS 04 CMU ATTACHMENTS TO PRIMARY STRUCTURAL SYSTEMS ARCHITECTURAL AND MEP ENGINEER. IN THE EVENT OF CONFLICTS, THE
PRIOR TO COMPLETION OF THE STRUCTURE. CONTRACTOR SHALL DESIGN AND 04 CMU REINFORCEMENT CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT, STRUCTURAL
PROVIDE SPECIFIED ITEMS LISTED IN GENERAL NOTES SECTION 1.2. 1. EMPLOY OR RETAIN A LICENSED PROFESSIONAL ENGINEER IN THE STATE WHERE 05 STRUCTURAL STEEL ENGINEER, AND MEP ENGINEER. Structural Engineer
THIS PROJECT IS LOCATED TO DESIGN AND DETAIL THE FOLLOWING STRUCTURAL 05 STRUCTURAL STEEL CONNECTIONS (CALCULATIONS
2. THE SPECIFICATIONS AND STRUCTURAL DRAWINGS REPRESENT THE WHEN SPECIFIED) 10. THE CONTRACTOR SHALL USE QUALIFIED, EXPERIENCED, PERSONNEL FOR Fink Roberts & Petrie, Inc.
CLADDING, CLADDING BACKUP AND SITE COMPONENTS:
REQUIREMENTS FOR THE COMPLETED STRUCTURE AND DO NOT INDICATE THE 05 STEEL ROOF DECK DEMOLITION AND REMOVAL OPERATIONS. PERFORM DEMOLITION AND REMOVAL 9449 Priority Way W Dr #200
METHOD OF CONSTRUCTION, UNLESS OTHERWISE NOTED. THE CONTRACTOR IS A. FOUNDATIONS AND EARTHWORK: 05 COLD FORMED METAL FRAMING OPERATIONS IN A CAREFUL AND ORDERLY MANNER TO PREVENT DAMAGE TO Indianapolis, Indiana 46240
SOLELY RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES, SEQUENCES, • TEMPORARY EXCAVATION SUPPORT 05 MISCELLANEOUS STRUCTURAL STEEL PROPERTY, HAZARDS TO PERSONS, AND THE SPREADING OF DUST AND DEBRIS.
31 FOUNDATION LAYOUT, SIZES, LENGTHS AND REINFORCING
317-872-8400
AND OPERATION OF CONSTRUCTION AS WELL AS SAFETY PRECAUTIONS AND • UNDERPINNING AND PERMANENT EXCAVATION SUPPORT
PROGRAMS INCIDENTAL THERETO. 11. IT IS NOT PERMISSIBLE TO ALLOW PORTIONS OF THE STRUCTURE TO FALL, NOR
B. DIVISION 2: ALLOW DEBRIS TO DROP, EXCEPT BY METHODS WHICH WILL NOT COMPROMISE
3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND • TEMPORARY BRACING/SHORING DURING DEMOLITION 3. THE FOLLOWING ITEMS REQUIRE SHOP DRAWINGS TO BE SUBMITTED BY THE INTEGRITY OF THE STRUCTURE. Mechanical / Electrical Engineer
REMOVAL OF ALL TEMPORARY BRACING AND CONSTRUCTION SUPPORTS FOR CONTRACTOR FOR LIMITED REVIEW BY THE STRUCTURAL ENGINEER ONLY FOR
NEW AND EXISTING STRUCTURES, AS NECESSARY TO COMPLETE THE PROJECT. IMPACT OF ATTACHMENTS TO THE STRUCTURE: 12. PRIOR TO THE START OF THE WORK, VERIFY THAT THE SCOPE OF DEMOLITION
R.E. Dimond & Associates, Inc.
C. DIVISION 4:
NO PORTION OF THE PROJECT WHILE UNDER CONSTRUCTION IS NECESSARILY • MASONRY ATTACHMENTS TO STRUCTURAL FRAME INDICATED ON THE CONTRACT DOCUMENTS SHALL NOT DAMAGE, CUT OR DISRUPT 732 N Capitol Avenue
STABLE IN THE ABSENCE OF THE CONTRACTOR’S TEMPORARY BRACES AND • STONE CLADDING SYSTEMS DESCRIPTION SERVICE OF ANY MECHANICAL SYSTEM, ELECTRICAL SYSTEM, OR UTILITY Indianapolis, Indiana 46204
SUPPORTS. WHERE SPECIFICALLY NOTED, THE DESIGN OF SUCH TEMPORARY • STONE CLADDING BACKUP SYSTEMS EMBEDDED IN THE EXISTING STRUCTURE THAT IS REQUIRED TO REMAIN IN USE 317-634-4672
BRACING AND CONSTRUCTION SUPPORT SHALL BE PERFORMED BY A ARCHITECTURAL ORNAMENTATION (FLAGPOLES, BANNERS, MASTS, ETC.) DURING OR AFTER CONSTRUCTION.
PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS D. DIVISION 5 STONE CLADDING AND CLADDING BACKUP SYSTEMS
LOCATED. • STRUCTURAL STEEL ERECTION AND TEMPORARY BRACING COLD-FORMED METAL FRAMING 13. DO NOT REMOVE MORE OF THE EXISTING STRUCTURE THAN INDICATED ON
REQUIRED DURING ERECTION ROOFTOP FALL PROTECTION CONTRACT DOCUMENTS UNLESS APPROVED IN WRITING BY THE STRUCTURAL
4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS, NEW AND • STRUCTURAL STEEL CONNECTIONS STAIR FRAMING HANDRAILS AND GUARDRAILS ENGINEER. DO NOT DAMAGE, MAR, CUT, OR DEFACE THE REMAINING STRUCTURE
EXISTING, BY MEASUREMENTS AND SURVEYS AT THE JOB SITE, PRIOR TO • NON-LOAD BEARING COLD FORMED METAL STUDS FOR EXTERIOR CURTAINWALLS AND OTHER GLAZING SYSTEMS OR MATERIALS TO BE REUSED.
SUBMITTAL OF SHOP DRAWINGS. THE CONTRACTOR SHALL TAKE ANY AND ALL WALLS SKYLIGHTS AND MONITORS
OTHER MEASUREMENTS NECESSARY TO VERIFY CONFORMANCE WITH THE • COLD FORMED METAL STUD WALL CONNECTIONS AND WINDOW WASHING DAVIT SYSTEMS 14. THE COST FOR REMOVING DEMOLISHED MATERIALS FROM THE SITE IN
DRAWINGS AND TO PERFORM THE WORK PROPERLY. NOTIFY OWNER'S ATTACHMENTS TO STRUCTURAL FRAME GRATING ACCORDANCE WITH ALL APPLICABLE LAWS, CODES, AND REGULATIONS SHALL BE
REPRESENTATIVE, ARCHITECT AND STRUCTURAL ENGINEER OF ANY • STAIRS AND HANDRAIL SYSTEMS INCLUDED IN THE CONTRACTOR’S BID.
DISCREPANCIES PRIOR TO PROCEEDING WITH WORK IN THE AREA OF QUESTION. • COLD FORMED METAL FLOOR AND ROOF FRAMING CONNECTIONS SHOP DRAWINGS SHALL SHOW THE MAGNITUDES, DIRECTIONS AND
CONNECTION CONDITIONS OF ALL LOADS IMPOSED ON THE SUPPORTING
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE E. EXTERIOR BUILDING ENVELOPE: STRUCTURE.
STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND • CURTAINWALL AND GLAZING BACKUP SYSTEMS
PLUMBING DRAWINGS, AS WELL AS ANY OTHER APPLICABLE TRADES. IN CASE OF • CURTAINWALL AND OTHER GLAZING CLADDING SYSTEMS THE SUBMITTAL SHALL LIST THE DESIGN LOADS USED AND BE SIGNED AND 2.0 FOUNDATIONS
CONFLICT BETWEEN STRUCTURAL WORK AND DRAWINGS RELATED TO OTHER • CLADDING ATTACHMENTS TO PRIMARY STRUCTURAL SYSTEM OR SEALED BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE IN WHICH
TRADES, THE CONTRACTOR SHALL MAKE ALLOWANCES IN THEIR BID FOR THE CLADDING BACKUP SYSTEM THE PROJECT IS LOCATED. 1. PREPARE AREAS OF THE SITE SUPPORTING STRUCTURE BY REMOVING TOPSOIL,
MORE SEVERE REQUIREMENTS. CONFLICTS BETWEEN THE STRUCTURAL WORK • ALL OTHER CLADDING SYSTEMS SUCH AS TERRA COTTA PANELS, EXISTING FILL, ORGANIC MATERIAL, OR FROZEN, WET, SOFT, LOOSE OR
AND THE DRAWINGS OF OTHER TRADES SHALL NOT BE REASON FOR EXTRA COST METAL PANELS, ETC. 4. OMISSION OF ANY MATERIALS REQUIRED BY THE CONTRACT DOCUMENTS FROM OTHERWISE UNSUITABLE MATERIALS.
OR DELAY IN THE EXECUTION OF THE WORK. • ROOFTOP FALL PROTECTION SYSTEM SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY
• STRUCTURAL MONITOR SYSTEMS FOR FURNISHING THESE MATERIALS REGARDLESS OF WHETHER THE SUBMITTALS 2. PROOF ROLL THE EXPOSED SUBGRADE WITH SUITABLE EQUIPMENT APPROVED BY
6. ALL FIELDWORK SHALL BE COORDINATED AND CONTINUOUSLY SUPERVISED BY HAVE BEEN REVIEWED. THE OWNER’S TESTING AGENCY TO DETERMINE IF ANY POCKETS OF SOFT,
THE CONTRACTOR. F. DIVISION 9 UNSUITABLE MATERIAL EXISTS BENEATH THE EXPOSED SUBGRADE. REMOVE ANY
• NON-LOAD BEARING COLD FORMED METAL STUDS FOR INTERIOR 5. THE USE OF ELECTRONIC FILES OR REPRODUCTIONS OF THE CONTRACT UNSUITABLE MATERIAL ENCOUNTERED AND REPLACE WITH A WELL COMPACTED
7. MATERIALS AND EQUIPMENT SHALL BE STORED AND TRANSPORTED IN A MANNER WALLS DOCUMENTS BY THE CONTRACTOR SIGNIFIES CONTRACTOR'S ACCEPTANCE OF GRANULAR MATERIAL.
SO AS NOT TO EXCEED THE ALLOWABLE FLOOR LOADINGS INDICATED IN THE ALL THE INFORMATION SHOWN "AS IS". CONTRACTOR WILL BE RESPONSIBLE FOR
DRAWINGS. 2. DRAWING SUBMITTALS FOR DELEGATED DESIGN COMPONENTS SHALL BE VERIFYING THE ACCURACY AND COMPLETENESS OF THE INFORMATION PROVIDED. 3. PLACEMENT AND COMPACTION OF ENGINEERED FILL SHALL BE OVERSEEN BY THE
REVIEWED AND SEALED BY THE COMPONENT ENGINEER PRIOR TO THE LIMITED ISSUED DRAWINGS AND SPECIFICATIONS TAKE PRECEDENCE OVER ANY OWNER’S TESTING AGENCY. PLACE FILL MATERIAL IN LAYERS NOT EXCEEDING 8
8. THE CONTRACTOR SHALL VERIFY WITH THE GEOTECHNICAL ENGINEER THAT THE REVIEW BY THE PROJECT’S STRUCTURAL ENGINEER OF RECORD. DELEGATED ELECTRONIC INFORMATION PROVIDED. ADDENDA, CHANGE ORDERS, INCHES IN LOOSE THICKNESS. MECHANICALLY COMPACT EACH LAYER TO AT
PROPOSED CONSTRUCTION PROCEDURES AND SEQUENCES FOLLOW THE DESIGN SUBMITTALS WILL BE REVIEWED ONLY FOR DESIGN LOADING SUPPLEMENTAL INSTRUCTIONS ARE NOT NECESSARILY INCLUDED IN THE LEAST THE REQUIRED MINIMUM DRY DENSITY. REQUIREMENTS FOR MATERIALS,
RECOMMENDATIONS WITHIN THE GEOTECHNICAL REPORT. CONFORMANCE TO SPECIFIED PROJECT PERFORMANCE CRITERIA AS WELL AS ELECTRONIC FILES. COMPACTION METHODS AND FIELD QUALITY CONTROL ARE OUTLINED IN DIVISION
IMPACT TO THE PRIMARY STRUCTURE FROM THE COMPONENT ATTACHMENTS. 31 OF THE PROJECT MANUAL.
9. THE CONTRACTOR SHALL MAKE NO DEVIATION FROM THE DESIGN DRAWINGS THE ENGINEER OF RECORD SHALL BE ENTITLED TO RELY ON THE ADEQUACY, 6. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL CONTRACT
WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT AND STRUCTURAL ACCURACY, AND COMPLETENESS OF THE DESIGN PROVIDED BY THE DOCUMENTS, INCLUDING LATEST ADDENDA, AND TO DISTRIBUTE TO ALL 4. FOOTINGS NOT SUPPORTED BY ENGINEERED FILL SHOULD BEAR ON FIRM
ENGINEER. CONTRACTOR. SUBCONTRACTORS PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS. UNDISTURBED MATERIAL. MATERIAL SHALL MEET THE REQUIRED SOIL BEARING
PRESSURE. IF UNSUITABLE MATERIAL IS ENCOUNTERED, REESTABLISH THE
10. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE, ARCHITECT 3. THE COMPONENT ENGINEER IS RESPONSIBLE FOR CODE CONFORMANCE FOR ALL BEARING ELEVATION OF THE FOOTING BY LOCALIZED UNDERCUTTING, AND FILLING
AND STRUCTURAL ENGINEER OF ANY DISCREPANCIES BETWEEN THE INDIVIDUAL PARTS AND INTERNAL CONNECTIONS OF THE PERFORMANCE WITH SUITABLE GRANULAR MATERIAL OR LEAN CONCRETE AS RECOMMENDED BY
STRUCTURAL DRAWINGS, DETAILS, AND SPECIFICATIONS, FOR RESOLUTION PRIOR SPECIFIED COMPONENTS. 1.4 CONSTRUCTION QUALITY ASSURANCE AND STRUCTURAL OBSERVATION THE OWNER'S TESTING AGENCY.
TO PROCEEDING WITH THE WORK. DO NOT ASSUME THAT EITHER THE DRAWINGS
OR SPECIFICATIONS TAKE PRECEDENCE. 4. SHOP DRAWINGS FOR DELEGATED DESIGN COMPONENTS SHALL INDICATE 1. SEE DIVISION 1 OF THE SPECIFICATIONS AND EACH TECHNICAL SPECIFICATION 5. PLACE FOOTINGS THE SAME DAY EXCAVATIONS ARE OPENED. IF THIS IS NOT
MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON PRIMARY AND SECTION FOR OWNER’S TESTING AND INSPECTION PROGRAM. CONTRACTOR IS TO POSSIBLE, ADEQUATELY PROTECT THE EXPOSED MATERIAL IN THE BASES OF THE
11. THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY SECONDARY STRUCTURAL ELEMENTS IN ENGLISH IMPERIAL UNITS ALONG WITH COORDINATE THE TESTING AND INSPECTION WORK WITH THE OWNER’S TESTING FOOTING EXCAVATIONS FROM ANY DETRIMENTAL CHANGE IN CONDITION SUCH AS
MECHANICAL UNIT SUPPORTED BY THE STRUCTURE, NOT INDICATED ON THE STRUCTURAL DEFLECTIONS THE COMPONENTS ARE ABLE TO ACCOMMODATE. AND INSPECTION AGENCY. FROM DISTURBANCE, RAIN OR FREEZING OR EXTREME DRYING. SURFACE RUNOFF
STRUCTURAL DRAWINGS, WITH WEIGHT GREATER THAN 500 LB. SHALL NOT BE ALLOWED TO ENTER THE EXCAVATIONS.
5. CALCULATIONS SUBMITTED SHALL CLEARLY CROSS REFERENCE THE SHOP 2. SITE OBSERVATION BY THE STRUCTURAL ENGINEER FOR GENERAL
12. SEE CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND VERTICAL DRAWINGS WITH SPECIFIC DETAIL REFERENCES. CONFORMANCE DOES NOT INCLUDE OR REPLACE THE SPECIAL INSPECTIONS 6. STRUCTURAL SLABS AND SLABS ON GRADE WHICH PROVIDE TOP AND BOTTOM
TRANSPORTATION DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL SPECIFIED FOR STRUCTURAL COMPONENTS. SUCH VISITS AND OBSERVATIONS SUPPORT FOR CONCRETE WALLS RETAINING EARTH, MUST BE IN PLACE AND HAVE
INFORMATION RELATING TO THE COORDINATION OF STRUCTURAL COMPONENTS 6. WHERE NOTED, TYPICAL DETAILS INDICATE GENERAL CRITERIA FOR DESIGN AND ARE NOT INTENDED TO BE AN EXHAUSTIVE CHECK OR DETAILED INSPECTION OF REACHED 70 PERCENT OF THEIR REQUIRED 28 DAY COMPRESSIVE STRENGTH
INCLUDING, BUT NOT LIMITED TO: DETAILING OF STRUCTURAL STEEL CONNECTIONS. TYPICAL DETAILS ARE NOT THE CONTRACTOR’S WORK, AND DO NOT RELIEVE THE CONTRACTOR OF THEIR BEFORE BACKFILLING OPERATIONS BEGIN.
INTENDED TO CONVEY COMPLETE CONNECTOR SIZES, PLATE SIZES, WELD SIZES, RESPONSIBILITY. ALL NOTED NON CONFORMING ITEMS SHALL BE ADDRESSED IN
A. CIVIL NUMBER OF BOLTS, OR ANY OTHER SPECIFIC INFORMATION THAT IS OBTAINED WRITING BY THE CONTRACTOR PRIOR TO SUBSTANTIAL COMPLETION. 7. CONCRETE WALLS RETAINING EARTH MUST HAVE REACHED 100 PERCENT OF
• PROJECT DATUM THROUGH DESIGNING OF AN INDIVIDUAL CONNECTION FOR A GIVEN SET OF THEIR REQUIRED 28 DAY COMPRESSIVE STRENGTH BEFORE BACKFILLING
• SITING OF BUILDING GRID LINES WITH RESPECT TO ADJACENT LOADS. SEE DIVISION 5 SPECIFICATIONS. OPERATIONS BEGIN.
BENCHMARKS SITE PREPARATION SEAL | DATE 04/01/21
• BACKFILLING MATERIALS AND REQUIREMENTS 8. SIMULTANEOUSLY BACKFILL EACH SIDE OF CONCRETE WALLS WITH EARTH ON
• PAVING AND SITE ELEMENTS OUTSIDE OF THE BUILDING ENVELOPE BOTH SIDES TO PLUS OR MINUS TWO FEET.
• TEMPORARY EXCAVATION SUPPORT LOCATION REQUIREMENTS
• UNDERSLAB DRAINAGE SYSTEMS AND PERIMETER FOUNDATION 9. BACKFILL PLACED AGAINST CONCRETE WALLS SHALL BE A WELL-GRADED
DRAINS GRANULAR MATERIAL. REQUIREMENTS FOR MATERIALS AND COMPACTION
• NEW AND EXISTING SITE UTILITIES METHODS ARE OUTLINED IN DIVISION 31 OF THE PROJECT MANUAL.
B. ARCHITECTURAL 10. FOR INFORMATION REGARDING SUBSURFACE CONDITIONS, REFER TO
• PLAN DIMENSIONS AND PROJECT DATUM GEOTECHNICAL ENGINEERING INVESTIGATION REPORT. SEE ALSO GEOTECHNICAL
• FINISH FLOOR ELEVATIONS DESIGN INFORMATION INCLUDED WITH DESIGN INFORMATION PROVIDED.
• VAPOR BARRIER WATERPROOFING, DAMP PROOFING, AND
INSULATION DETAILS
• RAMP GEOMETRY, PITS, SLAB SLOPES, DEPRESSIONS AND
RECESSES 2.1 TEMPORARY EXCAVATION SUPPORT AND PERMANENT FOUNDATION SUPPORT
• EMBEDMENTS, INSERTS, BLOCK OUTS, ETC.
• CONCRETE FINISHES AND TOPPING SLABS 1. THE CONTRACTOR SHALL BE RESPONSIBLE TO ADEQUATELY PROTECT ALL SHEET ISSUE
• CONCRETE CURBS AND HOUSEKEEPING PADS ADJACENT STRUCTURES, PAVEMENT UTILITIES, GRADES AND PLANTINGS. 1 Construction Documents 04/01/21
• INTERIOR NON-STRUCTURAL MASONRY PARTITIONS WHERE NECESSARY, BRACE EXCAVATION SIDES WITH SYSTEMS AS DETERMINED
• FIRE RATINGS BY THE CONTRACTOR’S ENGINEER WITH ALL REQUIRED BRACING AND TIEBACKS.
• METAL PAN STAIRS
• OPERABLE PARTITIONS, SUSPENDED TOILET PARTITIONS 2. DESIGN OF PERMANENT FOUNDATION SUPPORT AND UNDERPINNING SYSTEMS IS
• PERMANENT ROOFTOP FALL PROTECTION SYSTEM LAYOUT BY CONTRACTOR. SYSTEMS SHOWN DRAWINGS ARE PICTORIAL PRESENTATION
• HANDRAIL AND GUARDRAIL LOCATIONS OF ONE POTENTIAL SYSTEM. CONTRACTOR IS RESPONSIBLE FOR ACTUAL
• CLADDING ATTACHMENT LOCATIONS SYSTEM SELECTION.

C. MECHANICAL, PLUMBING AND FIRE PROTECTION


• PIPE AND DUCT SIZES FOR OPENING AND SLEEVE COORDINATION
• FLOOR DRAINS, ROOF DRAINS 3.1 CONCRETE FORMWORK
• HOUSEKEEPING PADS FOR EQUIPMENT
• EQUIPMENT CURBS 1. REFER TO FORMED CONCRETE SURFACE CATEGORY TABLE PROVIDED WITH
DESIGN INFORMATION SHEET FOR FORMING REQUIREMENTS.
D. ELECTRICAL AND TELECOM
• CONDUIT PENETRATIONS THROUGH WALLS AND SLABS 2. TOLERANCES: REFER TO DIVISION 3 SPECIFICATION CONCRETE FORM WORK
SPECIAL TOLERANCES FOR ELEVATORS, SHAFT OPENINGS, ROUGH OPENINGS
E. VERTICAL TRANSPORTATION FOR DOORS, WINDOW AND SLAB EDGES.
• INSERTS, HANGERS, TRENCHES, PITS, CONDUITS IN WALLS AND
SLABS

G. EQUIPMENT SUPPORT, EMBEDMENTS, ANCHOR BOLTS

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

GENERAL NOTES
3/31/2021 5:22:19 PM

SHEET NUMBER

S-001
3.2 REINFORCING STEEL 5.0 STRUCTURAL STEEL 5.40 NON LOAD BEARING COLD FORMED METAL STUDS FOR EXTERIOR WALLS
AND SOFFITS
1. PROVIDE MINIMUM CONCRETE COVER FOR REINFORCING STEEL IN 1. STRUCTURAL STEEL CONSTRUCTION SHALL CONFORM TO AISC 360, THE
ACCORDANCE WITH THE ACI “BUILDING CODE REQUIREMENTS FOR AMERICAN INSTITUTE OF STEEL CONSTRUCTION “SPECIFICATION FOR 1. EXTERIOR WALL METAL STUD CLADDING BACKUP SYSTEMS AND THEIR
STRUCTURAL CONCRETE” (ACI 318), UNLESS OTHERWISE INDICATED. STRUCTURAL STEEL BUILDINGS. CONNECTIONS TO THE STRUCTURE ARE TO BE DESIGNED, FURNISHED AND
INSTALLED BY THE CONTRACTOR. SEE CLADDING BACKUP DESIGN CRITERIA
FOR PERFORMANCE REQUIREMENTS
RHIT MOENCH
2. SPREAD REINFORCING STEEL AROUND SMALL OPENINGS AND SLEEVES IN 2. SHOP CONNECTIONS, UNLESS OTHERWISE SHOWN, MAY BE EITHER BOLTED OR
SLABS AND WALLS, WHERE POSSIBLE, AND WHERE BAR SPACING WILL NOT
EXCEED 1.5 TIMES THE NORMAL SPACING. DISCONTINUE BARS AT LARGE
OPENINGS, WHERE NECESSARY, AND PROVIDE AN AREA OF REINFORCEMENT,
WELDED. FIELD CONNECTIONS SHALL BE BOLTED UNLESS OTHERWISE
DETAILED ON THE DRAWINGS. 2. SEE DIVISION 5 SPECIFICATION SECTIONS OF THE PROJECT MANUAL FOR
ADDITIONAL CRITERIA.
RENOVATION
EQUAL TO THE INTERRUPTED REINFORCEMENT, IN FULL LENGTH BARS,
DISTRIBUTING ONE-HALF EACH SIDE OF THE OPENING. WHERE SHRINKAGE AND
3. BOLTED CONNECTIONS SHALL BE BEARING-TYPE CONNECTIONS USING 3/4 INCH
DIAMETER ASTM A325-N BOLTS WITH STANDARD 13/16 INCH DIAMETER HOLES, 3. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND FOR
REQUIRED DEPTHS OF MEMBERS TO BE INTEGRATED INTO THE WALL SECTIONS.
5500 Wabash Avenue
TEMPERATURE REINFORCEMENT IS INTERRUPTED, ADD (2)-#5 x OPENING UNLESS OTHERWISE NOTED OR DETAILED ON THE DRAWINGS, OR APPROVED
DIMENSION +4’-0’ ON EACH SIDE OF THE OPENING. PROVIDE #5 x 4’-0” DIAGONAL
BARS IN BOTH FACES, AT EACH CORNER OF OPENINGS LARGER THAN 12 INCHES
BY THE STRUCTURAL ENGINEER. Terre Haute, Indiana
IN ANY DIRECTION. 4. PREPARATION OF FAYING SURFACES AND TENSIONING OF SLIP CRITICAL BOLTS
SHALL BE IN ACCORDANCE WITH THE “RCSC SPECIFICATION FOR STRUCTURAL 47803
3. MECHANICAL SPLICES, EMBEDDED DOWELS WITH MECHANICAL SPLICES, AND JOINTS USING HIGH STRENGTH BOLTS.” 5.41 COLD-FORMED METAL FRAMING
DOWEL BAR SUBSTITUTES, WHICH ARE USED IN LIEU OF LAP SPLICES, SHALL Owner
DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE REINFORCING BAR 5. TENSION BOLTS IN ACCORDANCE WITH SECTION 8 OF THE “SPECIFICATION FOR
PER ACI REQUIREMENTS, AND SHALL BE USED ONLY WHERE INDICATED OR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS”, UNLESS NOTED 1. SEE SECTION 054100 OF THE PROJECT MANUAL FOR ADDITIONAL Rose-Hulman Institute of Technology
WHERE APPROVED BY THE ENGINEER OF RECORD. OTHERWISE. INFORMATION AND CRITERIA. 5500 Wabash Avenue
2. COLD-FORMED METAL FRAMING (CFMF) MEMBERS THROUGHOUT THE Terre Haute, Indiana 47803
4. POSITION DOWELS FOR VERTICAL WALL REINFORCEMENT IN COLUMN 6. CONNECTIONS WHICH ARE NOT FULLY DETAILED ON THE STRUCTURAL 812-877-1511
FOOTINGS AND WALL FOOTING STEPS WITH 6 INCHES MAXIMUM BOTTOM DRAWINGS SHALL BE DESIGNED BY THE STEEL FABRICATOR IN ACCORDANCE DRAWINGS ARE DESIGNATED IN ACCORDANCE WITH THE STEEL STUD
COVER. WITH THE AISC “MANUAL OF STEEL CONSTRUCTION”, AND SHALL BE DESIGNED MANUFACTURERS ASSOCIATION (SSMA) IDENTIFICATION SYSTEM. ALL
AND DETAILED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE SUBMITTALS AND SHOP DRAWINGS PERTAINING TO CFMF SHALL ADHERE TO THE
5. FIELD BENDING OF REINFORCING STEEL IS PROHIBITED. THE PROJECT IS LOCATED. SAME IDENTIFICATION SYSTEM. ALL SECTIONS FURNISHED SHALL MEET OR
EXCEED THE SSMA LISTED SECTION PROPERTIES.
6. SEE DIVISION 1 AND DIVISION 3 SPECIFICATIONS OF THE PROJECT MANUAL FOR A. ALL STEEL CONNECTION FORCES INDICATED WITHIN THE DRAWINGS 3. REFER TO PLANS FOR WALL AND HEADER TYPES. REFER TO WALL AND
SPECIFIED INSPECTION REQUIREMENTS. COORDINATE POUR SCHEDULES WITH ARE SERVICE LEVEL LOADS (ASD) UNLESS NOTED OTHERWISE. HEADER SCHEDULES FOR MEMBER TYPE, SIZE, AND THICKNESS REQUIRED.
THE A/E AND THE INSPECTION AGENCY TO ALLOW ADEQUATE TIME AND
PREPARATION FOR OBSERVATION AND INSPECTION. B. BEAM END CONNECTIONS SHALL BE DESIGNED FOR THE VERTICAL 4. MINIMUM YIELD STRENGTH (FY) FOR ALL CFMF MEMBERS OF 33 AND 43 MIL (1/1000
SHEAR REACTIONS INDICATED ON THE FRAMING PLANS. WHERE SUCH INCHES) THICKNESS SHALL BE 33KSI. MINIMUM YIELD STRENGTH OF ALL CFMF
REACTIONS HAVE NOT BEEN INDICATED, NON-COMPOSITE BEAM MEMBERS OF 54, 68, AND 97 MIL THICKNESS SHALL BE 50KSI.
CONNECTIONS (BEAMS WITHOUT SHEAR STUDS) SHALL BE DESIGNED
FOR ONE-HALF THE BEAM LOAD CAPACITY AS GIVEN IN THE AISC
Architect
5. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL STRUCTURAL TRACK
“ALLOWABLE LOADS ON BEAMS” TABLE. SECTIONS USED IN LOAD-BEARING AND EXTERIOR WALLS SHALL BE T125 RATIO
3.3 CAST IN PLACE CONCRETE
WITH DEPTH TO MATCH SPECIFIED WALL. 101 South Pennsylvania Street
C. BEAM WEB SHEAR CONNECTIONS SHALL TYPICALLY BE DOUBLE
1. THE MIXING, HANDLING, PLACING, AND CURING OF CONCRETE SHALL BE IN ANGLES, 5/16 INCH MINIMUM THICKNESS, UNLESS DETAILED OTHERWISE, 6. ALL STUDS, TRACKS, BRIDGING AND ACCESSORIES SHALL BE FORMED FROM Indianapolis, Indiana 46204
ACCORDANCE WITH THE ACI “BUILDING CODE REQUIREMENTS FOR STRUCTURAL OR WHERE OTHERWISE PERMITTED BY TYPICAL BEAM CONNECTION STEEL HAVING A GALVANIZED COATING MEETING THE REQUIREMENTS OF 317-633-4040
CONCRETE” (ACI 318). DETAILS. ASTM A653. PROVIDE G60 COATING MINIMUM, UNLESS NOTED OTHERWISE.
PROVIDE G90 COATING AT FRAMING AT FRAMING OUTSIDE OF BUILDING
2. SEE ARCHITECTURAL DRAWINGS FOR CHAMFER REQUIREMENTS FOR CORNERS D. PRIOR TO THE REVIEW OF THE STRUCTURAL STEEL SHOP DRAWINGS, INSULATION ENEVELOPE, SUCH AS OVERHANGS, SOFFITS, ETC.. Structural Engineer
OF CONCRETE. WHERE NOT INDICATED, PROVIDE ¾” CHAMFERS ON EXPOSED SUBMIT CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS
CORNERS OF CONCRETE EXCEPT THOSE ABUTTING MASONRY. TO THE STRUCTURAL ENGINEER FOR REVIEW. 7. A MINIMUM UN-PUNCHED LENGTH OF 10” IS REQUIRED AT EACH END OF ALL
Fink Roberts & Petrie, Inc.
LOAD-BEARING AND EXTERIOR WALL STUDS. NO PUNCHING OF HOLES OF 9449 Priority Way W Dr #200
3. SEE DIVISION 3 SPECIFICATION, CAST-IN-PLACE CONCRETE SECTION, OF THE E. FOR CONNECTION DESIGN AND DETAILING, SET CONNECTION WORK ANY TYPE SHALL BE PERMITTED IN THESE AREAS. CFMF MEMBERS USED IN Indianapolis, Indiana 46240
PROJECT MANUAL FOR CONCRETE MIX PROPORTIONING REQUIREMENTS. POINT AT INTERSECTION OF MEMBER CENTERLINES, UNLESS HEADER CONSTRUCTION SHALL BE UN-PUNCHED FOR THEIR ENTIRE LENGTH. 317-872-8400
OTHERWISE NOTED OR UNLESS ECCENTRICITY IS ACCOUNTED FOR IN
4. SEE DIVISION 3 SPECIFICATION CONCRETE FORMWORK SECTION OF THE PROJECT CONNECTION DESIGN AND DOES NOT ADVERSELY IMPACT MEMBER 8. FIELD WELDING OF COLD FORMED FRAMING ELEMENTS SHALL NOT BE
MANUAL, FOR FORM REMOVAL AND RESHORING REQUIREMENTS. CAPACITY. PERMITTED FOR ANY ELEMENT OF THICKNESS LESS THAN 68 MILS, UNLESS
NOTED OTHERWISE. Mechanical / Electrical Engineer
5. SEE DIVISION 3 SPECIFICATION, CAST-IN-PLACE CONCRETE SECTION OF THE F. ALL BEAM REACTIONS, AXIAL FORCES AND MOMENTS ACT
PROJECT MANUAL, FOR HOT WEATHER CONCRETING REQUIREMENTS. R.E. Dimond & Associates, Inc.
CONCURRENTLY UON. 9. BOTH FLANGES OF LOAD-BEARING WALL STUDS SHALL BE ATTACHED TO
732 N Capitol Avenue
6. SEE DIVISION 3 SPECIFICATION, CAST-IN-PLACE CONCRETE SECTION OF THE THE TOP AND BOTTOM TRACKS WITH ONE #12 SCREW EACH FLANGE OR 1
G. BEAM REACTIONS ACT IN GRAVITY DIRECTION WHEREAS AXIAL FORCES INCH LONG FILLET WELDS EACH FLANGE. WELD OPTION NOT PERMITTED Indianapolis, Indiana 46204
PROJECT MANUAL, FOR COLD WEATHER CONCRETING REQUIREMENTS. AND MOMENTS ARE REVERSIBLE UON. 317-634-4672
FOR FIELD WELDING OF STUDS LESS THAN 68 MILS.
7. FINISHING OF SLABS: AFTER SCREEDING, BULL FLOATING AND FLOATING 7. FOR BEAMS FRAMING OVER THE TOP OF A COLUMN, PROVIDE 3/8 INCH 10. ALL WELDS SHALL BE PERFORMED BY OPERATORS QUALIFIED IN
OPERATIONS HAVE BEEN COMPLETED, APPLY FINAL FINISH AS INDICATED BELOW, STIFFENER PLATES EACH SIDE OF THE BEAM WEB UNLESS DETAILED ACCORDANCE WITH THE AMERICAN WELDING SOCIETY’S “STRUCTURAL
AND AS DESCRIBED IN DIVISION 3 SPECIFICATION, CAST-IN-PLACE CONCRETE OTHERWISE. WELDING CODE - SHEET METAL” (AWS D1.3)
SECTION OF THE PROJECT MANUAL.
8. LOCATE CENTERLINES OF DIAGONAL VERTICAL BRACING MEMBERS ON COLUMN 11. ALL WELDS SHALL BE TOUCHED UP WITH GALVANIZING PAINT.
• FLOOR SLABS, INTERIOR RAMPS AND STEPS TROWEL FINISH CENTERLINES UNLESS OTHERWISE INDICATED.
• EXTERIOR RAMPS AND STEPS BROOM FINISH
12. ALL STUDS SHALL HAVE FULL BEARING AGAINST THE INSIDE TRACK WEB TOP AND
9. SUB-BASE (LEVELING) PLATES WILL NOT BE ALLOWED UNDER COLUMN BASE BOTTOM. ALL STUDS SHALL BE CUT SQUARE.
• FINISHING OF FORMED SURFACES: REFER TO FORMED CONCRETE PLATES, UNLESS APPROVED BY STRUCTURAL ENGINEER.
SURFACE CATEGORY TABLE PROVIDED ON DESIGN INFORMATION
DRAWINGS FOR FINISHING REQUIREMENTS. 10. SPLICES SHALL BE ALLOWED ONLY AT LOCATIONS EXPLICITLY INDICATED ON 13. TRACK SPLICES WITHIN A WALL PANEL SHALL BE SECURELY ANCHORED TO A
THE STRUCTURAL DRAWINGS UNLESS APPROVED OTHERWISE IN WRITING BY COMMON ELEMENT (I.E. STUD OR HEADER) OR BUTT-WELDED TOGETHER.
THE STRUCTURAL ENGINEER.
8. TOLERANCES: REFER TO DIVISION 3 SPECIFICATION CONCRETE FORM WORK FOR 14. LATERAL BRIDGING CONSISTING OF 2 1/2” OR 1 1/2" COLD-ROLLED CHANNELS AND
SPECIAL TOLERANCE REQUIREMENTS AT OPENINGS FOR ELEVATORS, SHAFT 11. ALL STEEL MEMBERS AND EMBEDMENTS EXPOSED TO AN EXTERIOR OR 54 MIL CLIP ANGLES SHALL BE INSTALLED IN ALL LOAD-BEARING AND EXTERIOR
OPENINGS, ROUGH OPENINGS FOR DOORS, WINDOWS AND SLAB EDGES. UNCONDITIONED ENVIRONMENT SHALL BE PROTECTED WITH A HOT-DIPPED WALLS TO RESIST TORSIONAL FORCES. BRIDGING SHALL BE SPACED VERTICALLY
GALVANIZED FINISH OR APPROVED ZINC RICH EXTERIOR COATING SYSTEM, AT ONE-THIRD POINTS OF THE STUD CLEAR HEIGHT OR AT 4’-0” MAXIMUM
9. CURING OF SLABS: CURE SLABS WITH CURING COMPOUND OR MOISTURE UNLESS NOTED OTHERWISE. (WHICHEVER IS THE LESSER SPACING).
RETENTION COVERS AS DESCRIBED IN DIVISION 3 SPECIFICATION, CAST-IN-PLACE
CONCRETE SECTION OF THE PROJECT MANUAL. 15. MINIMUM TRACK FASTENING TO CONCRETE SLABS SHALL BE 0.177” DIAMETER
12. PROVIDE HOLES IN ALL STEEL AS REQUIRED TO PREVENT ANY ACCUMULATION POWDER ACTUATED FASTENERS WITH 1” MINIMUM PENETRATION INTO CONCRETE
OF WATER. PENETRATIONS ADDED TO MEMBERS FOR THIS PURPOSE SHALL BE AT EACH STUD.
10. SEE DIVISIONS 1 AND 3 OF THE PROJECT MANUAL FOR TESTING AND INSPECTION LIMITED IN SIZE SUCH AS NOT TO REDUCE MEMBER AND/OR CONNECTION
PROGRAM REQUIREMENTS. COORDINATE AS REQUIRED WITH THE TESTING AND CAPACITY, AND SHALL BE GROUND SMOOTH. 16. VOIDS BENEATH THE TRACKS SHALL NOT BE PERMITTED. REFER TO THE
INSPECTION AGENCY. CONCRETE SECTION OF THE GENERAL NOTES FOR FLOOR FLATNESS
13. ALL COPES, HOLES, OPENINGS AND MODIFICATIONS REQUIRED IN STRUCTURAL REQUIREMENTS. WHERE UNEVENNESS OF THE SUPPORTING FLOOR SLAB
STEEL MEMBERS FOR ERECTION OR THE WORK OF OTHER TRADES SHALL BE PREVENTS CONTINUOUS SOLID BEARING, THE BOTTOM TRACK SHALL BE
SHOWN ON THE SHOP DRAWINGS FOR APPROVAL BY THE ARCHITECT AND LEVELED IN A MANNER PROPOSED BY THE CONTRACTOR AND APPROVED BY THE
STRUCTURAL ENGINEER. ENGINEER OF RECORD.
3.5 POST INSTALLED ADHESIVE ANCHOR REINFORCING DOWELS
14. STEEL USING COMPLETE JOINT PENETRATION GROOVE WELDS THAT FUSE 17. CUTTING OF LOAD-BEARING OR EXTERIOR WALL STUDS, HEADERS, OR TRACKS IS NOT
1. ANCHOR DRILLED-IN DOWELS TO EXISTING CONCRETE WITH AN ADHESIVE THROUGH THE THICKNESS OF THE FLANGE OR WEB SHALL HAVE A MINIMUM PERMITTED WITHOUT THE EXPRESSED APPROVAL OF THE ENGINEER OF RECORD.
ANCHOR SYSTEM; SEE DIVISION 3 SPECIFICATION SECTION CAST-IN-PLACE CHARPY V-NOTCH IMPACT TESTING VALUE AS SPECIFIED IN AISC 360.
CONCRETE OF THE PROJECT MANUAL, FOR PRODUCT STANDARDS.
18. MULTIPLE STUDS ARRANGED AS A “STUD-COLUMN” SHALL BE WELDED TOGETHER
15. SEE DIVISION 1 OF THE PROJECT MANUAL AND STRUCTURAL STEEL IN GROUPS OF AT LEAST TWO STUDS WITH 2” WELDS AT TOP AND BOTTOM AND 1”
2. DRILLED HOLE SIZE AND INSTALLATION PROCEDURE SHALL BE IN ACCORDANCE SPECIFICATION SECTION, FOR STRUCTURAL STEEL TESTING AND INSPECTION WELDS AT 16” ON CENTER IN BETWEEN. WELDS SHALL BE PLACED ON BOTH SIDES
REQUIREMENTS. COORDINATE AS REQUIRED WITH THE TESTING AND OF STUD-COLUMN ASSEMBLY.
WITH THE MANUFACTURER’S PUBLISHED INSTALLATION INSTRUCTIONS (MPII).
INSPECTION AGENCY.

16. SEE STRUCTURAL STEEL SPECIFICATION SECTION, OF THE PROJECT MANUAL


AND SURFACE PREP AND PRIMER SCHEDULE ON STRUCTURAL DRAWINGS FOR
STRUCTURAL STEEL SHOP PAINTING REQUIREMENTS.
5.5 MISCELLANEOUS METALS FABRICATIONS
17. PROJECT IS CONSIDERED AS A NON-SELF-SUPPORTING STRUCTURE UNTIL
COMPLETION OF ERECTION OF ALL THE STRUCTURAL STEEL AND DECK WHICH 1. SEE DIVISION 1 AND DIVISION 5 SPECIFICATION SECTIONS OF THE PROJECT
IS REQUIRED FOR FRAMING STABILITY. THE LATERAL SYSTEM CONSISTS OF ALL MANUAL FOR SUMMARY OF SCOPE.
BRACING, BEAM-TO-COLUMN MOMENT CONNECTIONS (EXCEPT AT SIMPLE BEAM
CANTILEVER CONDITIONS), STEEL ROOF DECKING, ELEVATED CONCRETE 2. SEE ARCHITECTURAL AS WELL AS STRUCTURAL DRAWINGS FOR ADDITIONAL
SLABS, AND SLAB ON GRADE. ANY TEMPORARY ERECTION AND STABILITY MISCELLANEOUS STEEL CONSIDERED A PART OF THE MISCELLANEOUS STEEL
ELEMENTS REQUIRED BY THE STEEL ERECTOR SHALL REMAIN IN PLACE UNTIL PACKAGE.
ALL COMPONENTS OF THE PERMANENT LATERAL SYSTEM ARE INSTALLED AND
UNTIL CONCRETE WHICH IS PART OF THE LATERAL SYSTEM HAS REACHED 75%
OF DESIGN STRENGTH.

18. REFER TO THE AESS TABLE ON THE DESIGN INFORMATION DRAWING FOR SEAL | DATE 04/01/21
ARCHITECTURALLY EXPOSED STRUCTURAL STEEL REQUIREMENTS.

5.2 STEEL DECK

1. STEEL DECK CONSTRUCTION SHALL CONFORM TO THE STEEL DECK INSTITUTE’S


“DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS”.

2. DECK SHALL BE THREE OR MORE SPANS CONTINUOUS WHERE POSSIBLE, AND


CONFIGURED AS SHOWN ON THE DRAWINGS.

3. SEE DIVISION 1 OF PROJECT MANUAL STEEL DECK SPECIFICATION SECTIONS


FOR INSPECTION PROGRAM. CONTRACTOR SHALL COORDINATE AS REQUIRED SHEET ISSUE
WITH THE INSPECTION AGENCY.
1 Construction Documents 04/01/21
4. FASTEN STEEL ROOF DECK TO EACH SUPPORT AS INDICATED BY THE DETAILS
AND IN STRICT COMPLIANCE WITH THE DECK MANUFACTURER’S INSTRUCTIONS
AND THE SHOP DRAWINGS. REFER TO STEEL ROOF DECK SPECIFICATION
SECTION FOR ADDITIONAL INFORMATION.

5. SUSPENDED LIGHT FIXTURES, DUCTS, SPRINKLERS AND OTHER MEP SYSTEMS


ARE NOT TO BE SUPPORTED DIRECTLY BY THE STEEL ROOF DECK.

6. FOR ALL ROOF DECKS, PROVIDE DECK DEPTH, MINIMUM GAGE AS INDICATED ON
THE DRAWINGS..

7. PROVIDE ADEQUATE DECK ENCLOSURES AND ACCESSORIES FOR


CONSTRUCTION LOADS

8. CONTRACTOR SHALL COORDINATE DECK OPENING SIZES AND LOCATIONS FOR


ITEMS SHOWN ON ARCHITECTURAL AND MEP DRAWINGS AND APPLY TYPICAL
STRUCTURAL DETAILS AS REQUIRED BASED ON THE OPENING SIZE EVEN IF NOT
EXPLICITLY SHOWN ON THE STRUCTURAL DRAWINGS. ALL SUCH OPENINGS
SHALL BE SUBMITTED FOR REVIEW BY THE ARCHITECT, STRUCTURAL
ENGINEER, AND MEP ENGINEER.

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

GENERAL NOTES
3/31/2021 5:22:21 PM

SHEET NUMBER

S-002
RHIT MOENCH
DESIGN INFORMATION
CONCRETE SCHEDULE AESS CATEGORIES TABLE RENOVATION
CLASS f'c AIR CONTENT USED FOR REMARKS CATEGORY 1 2 3 4

1.0 GOVERNING BUILDING CODE


3 3000 PSI OPTIONAL FOOTINGS WATER REDUCING 1.1 SSPC-SP6 SURFACE PREP X X X X 5500 Wabash Avenue
ADMIXTURE REQUIRED 1.2 SHARP EDGES GROUND SMOOTH X X X X
1. 2014 INDIANA BUILDING CODE BASED UPON THE 2012 INTERNATIONAL BUILDING 4 4000 PSI OPTIONAL HIGH RANGE WATER 1.3 CONTINUOUS WELD APPEARANCE
1.4 ALL BOLT HEADS ON SAME SIDE CONSISTENT FROM
X X X X Terre Haute, Indiana
CODE AS WELL AS ASCE7-10 WHERE APPLICABLE. REDUCER REQUIRED

2.0 GEOTECHNICAL DESIGN CRITERIA


CONNECTION TO CONNECTION
1.5 WELD SPATTER REMOVED
X
X
X
X
X
X
X
X
47803
2.2 HALF STANDARD FABRICATION TOLERANCES X X X
Owner
2.3 REMOVED OR HIDDEN FABRICATION MARKS X X X
1. ASSUMED SPREAD FOOTINGS NET ALLOWABLE BEARING PRESSURE: Rose-Hulman Institute of Technology
COLUMNS = 2,000 PSF 4ESOG 4000 PSI 6% ± 1% EXTERIOR SLABS ON MID RANGE WATER 2.4 SMOOTH, UNIFORM WELDS X X X
GRADE INDICATED ON "S" REDUCER REQUIRED, 3.1 REMOVED OR HIDDEN MILL MARKS X X 5500 Wabash Avenue
DRAWINGS. INCLUDES CRUSHED STONE, 3.2 FILL AND GRIND SMOOTH BUTT AND PLUG WELDS X X Terre Haute, Indiana 47803
3.1 CONCRETE REINFORCING (ACI 318-11, PTI MANUAL 6TH ED. PTI M02)
SLABS IN AREAWAYS. SYNTHETIC FIBERS 3.3 ORIENT HSS SEAMS AWAY FROM VIEW X X 812-877-1511
1. REINFORCING BARS: ASTM A615, GRADE 60 REQUIRED 3.4 CROSS SECTIONAL ABUTTING SURFACE ALIGNED X X
2. WELDABLE REINFORCING BARS: ASTM A706, GRADE 60 3.5 JOINT GAP TOLERANCES MINIMIZED X X
3. WELDED WIRE FABRIC: ASTM A1064 4EXPSOG 4000 PSI OPTIONAL SLABS ON GRADE TO MID RANGE WATER
REMAIN EXPOSED REDUCER REQUIRED, 4.1 HSS SEAMS AWAY FROM VIEW X
4. EPOXY COATED REINFORCING ASTM A775, GRADE 60
SYNTHETIC FIBERS 4.2 WELDS CONTOURED AND BLENDED X
5. POST-TENSIONING TENDONS 1/2" Ø, LOW RELAXATION STRAND CONFORMING TO
ASTM A416, GRADE 270 REQUIRED 4.3 SURFACE IMPERFECTIONS FILLED AND WELDED X
4.4 WELD SHOW THROUGH MINIMIZED X
4SOG 4000 PSI OPTIONAL INTERIOR SLABS ON MID RANGE WATER
4.0 MASONRY (TMS402-11/ACI 530-11) GRADE REDUCER REQUIRED
1. SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, f'm = 2000 PSI 4PG 4000 PSI OPTIONAL STAIR TREADS, PEA GRAVEL MIX
LANDINGS AND THIN REINFORCE WITH
• UNITS: ALL EXTERIOR CLADDING BACK-UP AND INTERIOR PARTITION TOPPINGS 6x6/W2.9xW2.9 WELDED Architect
WALL CMU SHALL BE LIGHT WEIGHT, ASTM C90, TYP 1. MINIMUM WIRE FABRIC
RATIO
COMPRESSIVE STRENGTH OF UNITS SHALL BE 2800 PSI. AESS CATEGORIES TABLE NOTES:
• MORTAR: TYPE 'S' MORTAR IN ACCORDANCE WITH ASTM C270
101 South Pennsylvania Street
• GROUT: GROUT SHALL BE PROPORTIONED IN ACCORDANCE WITH ASTM UNLESS NOTED OTHERWISE, PROVIDE CATEGORIES AS Indianapolis, Indiana 46204
C476. GROUT SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF FOLLOWS WHERE STRUCTURAL STEEL IS EXPOSED TO VIEW: 317-633-4040
2500 PSI AT 28 DAYS.
1. EXPOSED TO PUBLIC VIEW BUT NOT CRITICAL.
5.0 METALS NOTES: Structural Engineer
2. MORE THAN 20 FEET FROM HIGHEST VIEWING LEVEL.
5.1 STRUCTURAL STEEL (AISC 360-10, 2009 SPECIFICATION FOR STRUCTURAL JOINTS
Fink Roberts & Petrie, Inc.
1. SEE DIVISION 3 CONCRETE SPECIFICATIONS FOR CONCRETE MIX PROPORTIONING AND
USING HIGH STRENGTH BOLTS.) SUBMITTAL REQUIREMENTS. 3. WITHIN 20 FEET OF VIEWING LEVEL. 9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
1. ANCHOR RODS: ASTM F1554 GRADES 36 TYPICAL, 55 AND 105 AS NOTED. 2. ANY CONCRETE NOT INDICATED IN THE SCHEDULE SHALL BE CLASS 4. 4. TOUCHABLE FROM VIEWING SURFACE. 317-872-8400
2. PLATES: A572 GR 50
3. CHANNELS : ASTM A992 3. INCLUDE AN AIR ENTRAINING ADMIXTURE IN MIX DESIGNS FOR CONCRETE EXPOSED
4. ANGLES: A36 OR A572 GR 50 WHERE NOTED TO FREEZING AND THAWING DURING SERVICE AND FOR CONCRETE EXPOSED TO COLD
5. WIDE FLANGE AND TEE SHAPES: ASTM A992 WEATHER (AS DEFINED IN DIVISION 3 CONCRETE SPECIFICATION) DURING Mechanical / Electrical Engineer
6. SQUARE AND RECTANGULAR HSS: ASTM A500, GRADE C, Fy = 50 KSI CONSTRUCTION BEFORE ATTAINING ITS REQUIRED 28 DAY COMPRESSIVE STRENGTH. R.E. Dimond & Associates, Inc.
7. ROUND HSS: ASTM A500, GRADE C, Fy = 46 KSI THE CONCRETE CONTRACTOR & SUPPLIER SHALL TAKE APPROPRIATE STEPS TO
8. STEEL PIPE: ASTM A53, GRADE B, Fy = 35 KSI COMPENSATE FOR THE LOSS OF AIR-ENTRAINMENT DURING PUMPING. 732 N Capitol Avenue
9. BOLTS: ASTM F3125 GRADE A325 AND A490 Indianapolis, Indiana 46204
10. WELDS: E70XX 4. WHERE INCREASED SLUMP ABOVE ALLOWABLE LIMITS INDICATED IN THE 317-634-4672
SPECIFICATION IS DESIRED TO FACILITATE PLACEMENT OR PUMPING, SLUMP
INCREASE SHALL BE ACHIEVED UTILIZING AN APPROPRIATE APPROVED ADMIXTURE,
5.3 STEEL DECKING (SDI SPECIFICATION RD 1.0-10, NC 1.0-10, C2011, DDM-03) SUBMITTED FOR REVIEW AS PART OF THE CONCRETE MIX DESIGN PRIOR TO USE.
CONCRETE WITH HIGH-RANGE WATER REDUCING ADMIXTURE SHALL HAVE A MAXIMUM
5.4 COLD FORMED METAL STUD FRAMING (AISI S100-07/S2-10, S200-07, S210-07, S211-07, SLUMP OF 3 INCHES PRIOR TO ADDITION OF ADMIXTURE. WATER SHALL NOT BE
S212-07, S214-07) ADDED TO CONCRETE AT THE PROJECT SITE WITHOUT THE ENGINEER'S APPROVAL.

5.5 POST INSTALLED ANCHOR MATERIAL: ASTM F1554, GRADE 55 UNLESS NOTED
OTHERWISE

6.0 DESIGN LOADS FOR STRUCTURAL FRAME:


MINIMUM WALL CLADDING DESIGN PRESSURES
1. FRAME GRAVITY LOADS:
A. LIVE LOAD = 100 PSF
B. SUPERIMPOSED DEAD LOAD = 15 PSF EFFECTIVE ZONE 4 ZONE 5
C. SNOW LOAD:
a. DESIGN GROUND SNOW LOAD, Pg = 20 PSF WIND AREA
b. DESIGN FLAT-ROOF SNOW LOAD, Pf = 16 PSF
c. SNOW EXPOSURE FACTOR, Ce = 1.0 10 SF +25.9 PSF +25.9 PSF
d. SNOW LOAD IMPORTANT FACTOR, Is = 1.1 -28.1 PSF -34.6 PSF
e. THERMAL FACTOR, Ct = 1.0
50 SF +23.3 PSF +23.3 PSF
-25.4 PSF -29.2 PSF
2. FRAME WIND LOADS
A. BASIC WIND SPEED (ULTIMATE) = 115 MPH +22.1 PSF +22.1 PSF
B. WIND EXPOSURE = B 100 SF
-24.3 PSF -26.9 PSF
C. MEAN ROOF HEIGHT (h) = 55 FT
200 SF +21.0 PSF +21.0 PSF
3. FRAME SEISMIC LOADS: (ASCE 7-10) -23.1 PSF -24.7 PSF
A. SEISMIC RISK CATEGORY = III
B. SITE CLASSIFICATION: SITE CLASS C +19.5 PSF +19.5 PSF
500 SF -21.6 PSF -21.6 PSF
C. SEISMIC DESIGN CATEGORY = B
D. SEISMIC IMPORTANCE FACTOR, Ie = 1.25
E. MAPPED SPECTRAL RESPONSE ACCELERATIONS: Ss = 0.225, S1 = 0.113
NOTES:
F. ANALYSIS PROCEDURE: STATIC EQUIVALENT LATERAL FORCE
PROCEDURE IN ACCORDANCE WITH ASCE 7-10 1. PRESSURES ARE ULTIMATE LOADS.

7.0 DESIGN WIND AND SEISMIC LOAD CRITERIA FOR CLADDING AND CLADDING BACKUP: 2. TO OBTAIN WORKING LOADS FOR ASD DESIGN, MULTIPLY PRESSURES BY 0.6
IN ACCORDANCE WITH 2012 IBC LOAD COMBINATIONS.
1. CLADDING WIND LOADS: (ASCE 7-10) 3. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM
A. BUILDING IS TO BE CONSIDERED FULLY ENCLOSED SURFACE RESPECTIVELY.
a. INTERNAL PRESSURE COEFFICIENT, GCpi = + 0.18 4. ZONE LOCATIONS SHALL BE AS DEFINED BY THE DESIGN CRITERIA ELEVATIONS
b. EXTERNAL PRESSURE COEFFICIENTS ARE TO BE BASED ON AND SHALL NOT BE LESS THAN THOSE SHOWN IN ASCE 7-10 FIGURE 30.4-1 FOR
COMPONENT EFFECTIVE WIND AREA AND ASCE 7-10, FIGURE 30.4 MEAN ROOF UP TO 60' AND ASCE 7-10 FIGURE 30.6-1 FOR MEAN ROOF HEIGHT
OR 30.6 GREATER THAN 60'
B. TOPOGRAPHIC FACTOR, Kzt = 1.0
C. WIND DIRECTIONALITY FACTOR, Kd = 0.85
D. NOTE: ALLOWABLE STRESS INCREASE FOR WIND LOADING SHALL NOT
BE USED. (SEE ASCE 7-10, TABLE 26.6-1) MINIMUM ROOF CLADDING DESIGN PRESSURES

EFFECTIVE ROOF ROOF ROOF


WIND AREA ZONE 1 ZONE 2 ZONE 3
SEAL | DATE 04/01/21
10 SF +11.6 PSF +11.6 PSF +11.6 PSF
-28.3 PSF -47.5 PSF -71.5 PSF

50 SF +9.7 PSF +9.9 PSF +9.9 PSF


-26.7 PSF -35.8 PSF -43.0 PSF

100 SF +9.2 PSF +9.2 PSF +9.2 PSF


-25.9 PSF -30.7 PSF -30.7 PSF

200 SF +9.2 PSF +9.2 PSF +9.2 PSF


-25.9 PSF -30.7 PSF -30.7 PSF
+9.2 PSF +9.2 PSF +9.2 PSF
500 SF -25.9 PSF -30.7 PSF -30.7 PSF

NOTES: SHEET ISSUE


1. PRESSURES ARE ULTIMATE LOADS. 1 Construction Documents 04/01/21
2. TO OBTAIN WORKING LOADS FOR ASD DESIGN, MULTIPLY PRESSURES BY 0.6
IN ACCORDANCE WITH 2012 IBC LOAD COMBINATIONS.
3. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM
SURFACE RESPECTIVELY.
4. DESIGN UNDERSIDE OF EXTERIOR SOFFITS FOR ZONE 4 OR ZONE 5 WALL LOADS.
5. ZONE DEFINITIONS SHALL BE AS DEFINED BY THE ROOF UPLIFT KEY PLAN AND SHALL
NOT BE LESS THAN THOSE SHOWN IN ASCE 7-10 FIGURE 30.4-2 FOR MEAN ROOF UP TO
60' AND ASCE 7-10 FIGURE 30.6-1 FOR MEAN ROOF HEIGHT GREATER THAN 60'.

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

DESIGN
INFORMATION
3/31/2021 5:22:25 PM

SHEET NUMBER

S-003
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
2 812-877-1511
SD-200

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

E
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
F

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
G 317-634-4672

F
3 G
M E
2
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

V
PLAN NOTES:

1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA. DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

W PROJECT NO. 19040.000


SHEET TITLE

LOWER LEVEL 1
DEMOLITION PLAN
3/31/2021 5:14:45 PM

LOWER LEVEL 1 DEMOLITION PLAN


1 SCALE: 1/16" = 1'-0" SHEET NUMBER

SD-112
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
4 Terre Haute, Indiana 47803
SD-200 812-877-1511

2 / SD-500
DEMO
9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

E
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
F

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
G 317-634-4672

F
3 G
M E
2
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

6
SD-200

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
PLAN NOTES:
W PROJECT NO. 19040.000
1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE
SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA. SHEET TITLE

FIRST LEVEL
DEMOLITION PLAN
3/31/2021 5:14:55 PM

FIRST LEVEL DEMOLITION PLAN


NORTH

1 SCALE: 1/16" = 1'-0" SHEET NUMBER

SD-113
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

E
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
F

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
G 317-634-4672

F
3 G
M
3
E
2
SD-200
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

T
1
SD-200
9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

U
7
SD-200

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
PLAN NOTES: COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

W 1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE PROJECT NO. 19040.000
SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA.
SHEET TITLE

SECOND LEVEL
DEMOLITION PLAN
3/31/2021 5:15:06 PM

SECOND LEVEL DEMOLITION PLAN


1 SCALE: 1/16" = 1'-0" SHEET NUMBER

SD-114
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D Architect
RATIO
4
101 South Pennsylvania Street
● Indianapolis, Indiana 46204
SD-500
317-633-4040

E
4 Structural Engineer
SD-500 Fink Roberts & Petrie, Inc.
SEE ARCHITECTURAL DRAWINGS 9449 Priority Way W Dr #200
FOR NON-STRUCTURAL EXISTING Indianapolis, Indiana 46240
MONITOR DEMOLITION, TYPICAL 317-872-8400
F

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
G 317-634-4672

F
3 G
M E
2
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

REMOVE MISCELLANEOUS
STEEL FRAMING ABOVE ROOF;
VERIFY EXTENT WITH OWNER
PRIOR TO DEMOLITION
Q 3
SD-500
TYP
SHEET ISSUE
1 Construction Documents 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

5
SD-200
U

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
PLAN NOTES: DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE
W SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA. PROJECT NO. 19040.000
SHEET TITLE

ROOF DEMOLITION
PLAN
3/31/2021 5:15:14 PM

ROOF DEMOLITION PLAN


NORTH

1 SCALE: 1/16" = 1'-0" SHEET NUMBER

SD-115
5.1 4.1
16'-10" FIELD VERIFY

N10
RHIT MOENCH
S8
17'-3 1/4" FIELD VERIFY
S7
17'-3 1/4" FIELD VERIFY
S6

7'-6 1/4"
RENOVATION
3 9/16" 4'-9 7/16" 1 11/16"
FIELD VERIFY M
5500 Wabash Avenue
Terre Haute, Indiana

FIELD VERIFY
REMOVE EXISTING WOOD DECKING REMOVE BRIDGE
REMOVE EXISTING RAMP FRAMING AND SLAB

6'-0"
TO LEVEL SURFACE 47803
T C
Owner

FIELD VERIFY
(E) C12x20.7

4'-11 11/16"
Rose-Hulman Institute of Technology
5500 Wabash Avenue

18'-0" FIELD VERIFY


Terre Haute, Indiana 47803

5'-9 1/4"

FIELD VERIFY
812-877-1511

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) W5x16

(E) W5x16
7'-7 3/8"
5

6'-0"
1 / SD-500
SD-500

DEMO
18'-8 7/8" FIELD VERIFY
17'-7 7/8" FIELD VERIFY

CUT AND REMOVE EXISTING 10x12

FIELD VERIFY
TIMBER BEAM AFTER NEW

7'-8 1/2"
SUPPORT FRAMING IS INSTALLED (E) C12x20.7
(E) 10x12

FIELD VERIFY
9.8

6'-0"
Architect

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12
RATIO
101 South Pennsylvania Street

10'-0 1/2"
N
Indianapolis, Indiana 46204
317-633-4040
3" T&G
CUT AND REMOVE WOOD DECKING
EXISTING 10x16 TIMBER Structural Engineer
2'-0"5 9/16" GIRDER AFTER NEW SUPPORT Fink Roberts & Petrie, Inc.
FRAMING IS INSTALLED
9449 Priority Way W Dr #200
(E) 10x16 (E) 10x16
U Indianapolis, Indiana 46240
2'-6 7/8"

317-872-8400
7'-1 3/16"

12'-1" Mechanical / Electrical Engineer


ENLARGED DEMO PLAN - LOWER LEVEL 1 ENLARGED DEMO PLAN - SECOND LEVEL R.E. Dimond & Associates, Inc.
2 3

(E) 10x12
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672
17'-8 1/4" FIELD VERIFY

N5 N4
9'-5"

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12
S4 S3
REMOVE EXISTING
(E) W8x10 WOOD DECKING TO 2 3/4" 8'-4 1/4"
BEAM CENTERLINE

1'-4"
T
REMOVE EXISTING WOOD C
(E) W8x10
DECKING AFTER NEW REMOVE ROOF DECKING AS

2'-9"
FRAMING BELOW IS INSTALLED REMOVE EXISTING 10" SLAB REQUIRED TO INSTALL MECH

(E) 10x12
AFTER NEW FRAMING IS HOOD; COORDINATE SIZE AND
INSTALLED BELOW LOCATION WITH MEP
CONTRACTOR, SEE 6/S-500 FOR
(E) 10x16 (E) 10x16 TYPICAL ROOF DECK OPENING
V FRAMING

U
D

ENLARGED DEMO PLAN - SECOND LEVEL SOUTH ENLARGED DEMO PLAN - FIRST LEVEL ENLARGED DEMO PLAN - ROOF
1 SCALE: 1/4" = 1'-0"
4 SCALE: 1/8" = 1'-0"
5 SCALE: 1/8" = 1'-0"

S2
S8 S7 S6
17'-3 1/4" 17'-3 1/4" 6'-11 3/8" 1'-10 1/4"
FIELD VERIFY FIELD VERIFY

U SEAL | DATE 04/01/21


EXISTING 3" REMOVE AND REPLACE
EXISTING 3" WOOD DECKING
FIELD VERIFY

WOOD DECKING TO BEAM CENTERLINE AS


6'-2 5/8"
18'-8 7/8"

REQUIRED FOR CRAWL


SPACE ACCESS AND TO
INSTALL NEW COLUMN AND
(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12
(E) 10x12

(E) 10x12

(E) 10x12

FOOTING (3 LOCATIONS)
2'-0"

(E) 10x16 (E) 10x16


U

SHEET ISSUE
(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

1 Construction Documents 04/01/21

REMOVE EXISTING 3" WOOD


DECKING AFTER FRAMING
BELOW IS INSTALLED

ENLARGED DEMO PLAN - FIRST LEVEL ENLARGED DEMO PLAN - SECOND LEVEL
6 SCALE: 1/8" = 1'-0"
7 SCALE: 1/4" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

PLAN NOTES:
ENLARGED
1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE
DEMOLITION PLANS
SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA.
3/31/2021 5:15:22 PM

SHEET NUMBER

SD-200
5.9 5.1

C
7 1/2"
3'-6 1/2" 5'-11"
1'-1 7/8"
RHIT MOENCH
D
RENOVATION
6'-4" 2'-11" 5500 Wabash Avenue
07 ROOF LEVEL
148'-10 1/2"
Terre Haute, Indiana
EXISTING MONITOR;
SEE ARCHITECTURAL
47803
Owner
REMOVE EXISTING 1 1/2" DIAMETER ROD
REMOVE EXISTING VARYING
Rose-Hulman Institute of Technology
REMOVE EXISTING 18 1/2" THICK 5500 Wabash Avenue
MASONRY WALL AFTER NEW THICKNESS MASONRY WALL AFTER
LINTEL IS INSTALLED. NEW LINTEL IS INSTALLED. REMOVE EXISTING W10x49, EA SIDE Terre Haute, Indiana 47803
FIELD VERIFY WALL THICKNESS. FIELD VERIFY WALL THICKNESS. 812-877-1511

REMOVE EXISTING 4L CRUCIFORM


COLUMN EXTENSION, EA SIDE
7'-0"

EXISTING MECHANICAL CHASE;

7'-2"
SEE ARCHITECTURAL

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
02 LOWER LEVEL 1
110'-7 1/16" 03 FIRST LEVEL
120'-11 13/16" Structural Engineer
Fink Roberts & Petrie, Inc.
EXISTING DOOR 9449 Priority Way W Dr #200
OPENING Indianapolis, Indiana 46240
EXISTING W6x20 COLUMN TO REMAIN 317-872-8400

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
NORTHWEST CRAPO HALL ENTRY ELEVATION NORTHEAST STAIR TOWER ENTRY ELEVATION TYPICAL EXISTING MONITOR DEMOLITION SECTION 732 N Capitol Avenue
1 SCALE: 1/2" = 1'-0"
2 SCALE: 1/2" = 1'-0"
3 SCALE: 1/2" = 1'-0"
Indianapolis, Indiana 46204
317-634-4672

5.9

5.1

EXISTING MONITOR,
SEE ARCHITECTURAL

REMOVE EXISTING W10 04 SECOND LEVEL


PER 3/SD-500 130'-6 13/32"
TEMPORARILY SUPPORT
WOOD DECK AS REQUIRED
REMOVE EXISTING
REMOVE EXISITNG C9x13.4 SLAB CONSTRUCTION
PURLING BETWEEN GRIDS D & F

REMOVE EXISTING C10x15.3

DEMOLITION SECTION AT EXISTING MONITOR DEMOLITION SECTION


4 SCALE: 1/2" = 1'-0"
5 SCALE: 3/4" = 1'-0"

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

STRUCTURAL
DEMOLITION ELEV,
SECTIONS AND
3/31/2021 5:15:25 PM

DETAILS
SHEET NUMBER

SD-500
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

E
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
F

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
G 317-634-4672

F
3 G
M E
2
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

W PROJECT NO. 19040.000


SHEET TITLE

LOWER LEVEL 1
FLOOR PLAN
3/31/2021 5:22:34 PM

LOWER LEVEL 1 FLOOR PLAN


1 SCALE: 1/16" = 1'-0" SHEET NUMBER

S-102
RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

N10

Architect
A RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

B Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

4
S-501

9.8

F
3 G
E
2
E D

B 1
A

KEY PLAN

F SEAL | DATE 04/01/21

G
SHEET ISSUE
1 Construction Documents 04/01/21

LOWER LEVEL 1 FLOOR PLAN - AREA 3


1 SCALE: 1/8" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

LOWER LEVEL 1
FLOOR PLAN - AREA
3
3/31/2021 5:22:37 PM

SHEET NUMBER

S-102.3
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

E
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
F

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
G 317-634-4672

F
3 G
M E
2
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

W PROJECT NO. 19040.000


SHEET TITLE

FIRST LEVEL FLOOR


PLAN
3/31/2021 5:22:49 PM

FIRST LEVEL FLOOR PLAN


1 SCALE: 1/16" = 1'-0" SHEET NUMBER

S-103
9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2 PLAN NOTES:

1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE


SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA. RHIT MOENCH
2. SEE DRAWING S500 FOR STRUCTURAL STEEL COLUMN BASE
PLATE AND ANCHOR ROD DETAILS.
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
LEGEND
Owner
BFX INDICATES FOOTING MARK. "B" INDICATES REQUIRED
M BEARING CAPACITY IN KSF AND FX INDICATES BEARING MARK. Rose-Hulman Institute of Technology
5500 Wabash Avenue
TF INDICATES TOP OF FOOTING ELEVATION. Terre Haute, Indiana 47803
812-877-1511
TB INDICATES TOP OF BEAM ELEVATION.

INDICATES OPENING IN SLAB. COORDINATE SIZE AND


LOCATION WITH MECHANICAL CONTRACTOR.

A INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB


METAL ROOF DECK WITH (2) LAYERS OF 3/4" PLYWOOD

INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB


B METAL ROOF DECK
N INDICATES SPAN DIRECTION OF 3", LAMINATES SOUTHERN
C
Architect
PINE T&G ROOF DECKING
RATIO
(S) INDICATES SLOPING MEMBER 101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
SEE FOUNDATION PLAN, SLAB ON GRADE 317-872-8400
O
PLAN OR STEEL COLUMN SCHEDULE FOR
COLUMN BASE PLATE AND ANCHOR ROD
INFORMATION. SEE ANCHOR PLACEMENT Mechanical / Electrical Engineer
DETAILS FOR LAYOUT EMBEDMENT
LENGTH AND PROTECTION LENGTH. R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
SEE FOUNDATION PLAN 317-634-4672
2" NON-SHRINK GROUT
FOR TOP OF FOOTING

3' - 0". (MIN)


ELEVATION

2" CLR
3" CLR
P

3" CLR,
TYP
SEE COLUMN FOOTING SCHEDULE
FOR FOOTING INFORMATION

TYPICAL FOOTING WITH STEEL COLUMN

BEARING CAPACITY
COLUMN SQUARE FOOTING SCHEDULE 2 KSF

BOTTOM
MARK SIZE REMARKS
REINFORCEMENT

2F4 4'-0" x 4'-0" x 1'-6" (4) #6 E.W.

F
R
3 G
E
2
D

B 1
A

S
KEY PLAN

SEAL | DATE 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

6'-7" 27'-1 1/2" 10"

HSS6x6x5/16 HSS6x6x5/16 SHEET ISSUE


2F4 2F4 1 Construction Documents 04/01/21
TF 114'-9" (FV) 11
TF 114'-9" (FV)

S-502
10'-2 1/2"

(TYP)

HSS6x6x5/16
U 2F4
TF 114'-9" (FV)
2'-1 7/8"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

W PROJECT NO. 19040.000


SHEET TITLE

FIRST LEVEL FLOOR


PLAN - AREA 1
3/31/2021 5:22:56 PM

SHEET NUMBER
FIRST LEVEL FLOOR PLAN - AREA 1
1 SCALE: 1/8" = 1'-0"
S-103.1
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RHIT MOENCH
RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

C
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
1
9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2
S-200
Mechanical / Electrical Engineer
5
R.E. Dimond & Associates, Inc.
S-501
732 N Capitol Avenue
Indianapolis, Indiana 46204
D 317-634-4672

PLAN NOTES: F
1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE
3 G

SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA. E


2
2. SEE DRAWING S500 FOR STRUCTURAL STEEL COLUMN BASE
PLATE AND ANCHOR ROD DETAILS.
D

C
G
B 1
A
LEGEND

BFX INDICATES FOOTING MARK. "B" INDICATES REQUIRED


KEY PLAN
BEARING CAPACITY IN KSF AND FX INDICATES BEARING MARK.
SEAL | DATE 04/01/21
TF INDICATES TOP OF FOOTING ELEVATION.

TB INDICATES TOP OF BEAM ELEVATION.

H INDICATES OPENING IN SLAB. COORDINATE SIZE AND


LOCATION WITH MECHANICAL CONTRACTOR.

A INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB


METAL ROOF DECK WITH (2) LAYERS OF 3/4" PLYWOOD

INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB


B METAL ROOF DECK

INDICATES SPAN DIRECTION OF 3", LAMINATES SOUTHERN


C PINE T&G ROOF DECKING
SHEET ISSUE
(S) INDICATES SLOPING MEMBER
1 Construction Documents 04/01/21

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

FIRST LEVEL FLOOR


PLAN - AREA 2
3/31/2021 5:23:00 PM

FIRST LEVEL FLOOR PLAN - AREA 2


1 SCALE: 1/8" = 1'-0" SHEET NUMBER

S-103.2
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

E
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
F

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
G 317-634-4672

F
3 G
M E
2
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

W PROJECT NO. 19040.000


SHEET TITLE

SECOND LEVEL
FLOOR PLAN
3/31/2021 5:23:13 PM

SECOND LEVEL FLOOR PLAN


1 SCALE: 1/16" = 1'-0" SHEET NUMBER

S-104
9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2 RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
M 5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

C12x20.7
S-503

Architect
N
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

O
Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

PLAN NOTES:

1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE


SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA.

2. SEE DRAWING S500 FOR STRUCTURAL STEEL COLUMN BASE


PLATE AND ANCHOR ROD DETAILS.

LEGEND

BFX INDICATES FOOTING MARK. "B" INDICATES REQUIRED


BEARING CAPACITY IN KSF AND FX INDICATES BEARING MARK.

TF INDICATES TOP OF FOOTING ELEVATION. F


TB INDICATES TOP OF BEAM ELEVATION.
3 G

R
INDICATES OPENING IN SLAB. COORDINATE SIZE AND
E
2
LOCATION WITH MECHANICAL CONTRACTOR.
D
A INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB
METAL ROOF DECK WITH (2) LAYERS OF 3/4" PLYWOOD C
INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB
B METAL ROOF DECK B 1
INDICATES SPAN DIRECTION OF 3", LAMINATES SOUTHERN
C PINE T&G ROOF DECKING A
(S) INDICATES SLOPING MEMBER
KEY PLAN
S

SEAL | DATE 04/01/21

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

2 SHEET ISSUE
S-200 1 Construction Documents 04/01/21
9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

3
S-200

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


W SHEET TITLE

SECOND LEVEL
FLOOR PLAN - AREA
1
3/31/2021 5:23:20 PM

SHEET NUMBER
SECOND LEVEL FLOOR PLAN - AREA 1
1 SCALE: 1/8" = 1'-0" S-104.1
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1

RHIT MOENCH
A
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511
B

Architect
RATIO
101 South Pennsylvania Street
C Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2 9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


D R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

PLAN NOTES:

1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE


8 8 SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA.
● RAMP PER ARCH.
S-502 S-502
2. SEE DRAWING S500 FOR STRUCTURAL STEEL COLUMN BASE
8 PLATE AND ANCHOR ROD DETAILS.

S-502

LEGEND

BFX INDICATES FOOTING MARK. "B" INDICATES REQUIRED


1'-0" 7'-0" 7'-0" 7'-0" 7'-0" 1'-0" 1'-6 1/2" BEARING CAPACITY IN KSF AND FX INDICATES BEARING MARK.
F
MC6x15.3
TF INDICATES TOP OF FOOTING ELEVATION.
3 G

3/4" DIA. HANGER


TB INDICATES TOP OF BEAM ELEVATION. E
2
5'-3"

ROD, TYP INDICATES OPENING IN SLAB. COORDINATE SIZE AND


LOCATION WITH MECHANICAL CONTRACTOR. D
G
A INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB
METAL ROOF DECK WITH (2) LAYERS OF 3/4" PLYWOOD C
1
S-503 B
INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB
METAL ROOF DECK
B 1
INDICATES SPAN DIRECTION OF 3", LAMINATES SOUTHERN A
C PINE T&G ROOF DECKING

(S) INDICATES SLOPING MEMBER


KEY PLAN

SEAL | DATE 04/01/21


H

SHEET ISSUE
J
1 Construction Documents 04/01/21

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

SECOND LEVEL
FLOOR PLAN - AREA
2
3/31/2021 5:23:28 PM

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

SHEET NUMBER
SECOND LEVEL FLOOR PLAN - AREA 2
1 SCALE: 1/8" = 1'-0" S-104.2
RHIT MOENCH
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 RENOVATION
5500 Wabash Avenue
A
Terre Haute, Indiana
47803
Owner

B
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

9.8 8.9 7.9 6.9 5.9 5.1 4.1 3.1 2.1 1.2

D 6
● Architect
S-200
RATIO
(SIM)
101 South Pennsylvania Street
7 Indianapolis, Indiana 46204

S-502 317-633-4040

E
Structural Engineer
Fink Roberts & Petrie, Inc.
7 9449 Priority Way W Dr #200
S-502 Indianapolis, Indiana 46240
317-872-8400
F

8 Mechanical / Electrical Engineer


S-200 R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
7
Indianapolis, Indiana 46204
G 317-634-4672
S-200

J
4
S-200

F
3 G
M E
2
D

C
N
B 1
A

O KEY PLAN

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

S
5
S-200
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

T
6 PLAN NOTES:
S-200
1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE
SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA.

2. SEE DRAWING S500 FOR STRUCTURAL STEEL COLUMN BASE


PLATE AND ANCHOR ROD DETAILS.
U

LEGEND
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
BFX INDICATES FOOTING MARK. "B" INDICATES REQUIRED AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
BEARING CAPACITY IN KSF AND FX INDICATES BEARING MARK. DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

TF INDICATES TOP OF FOOTING ELEVATION.


W PROJECT NO. 19040.000
TB INDICATES TOP OF BEAM ELEVATION.
SHEET TITLE
INDICATES OPENING IN SLAB. COORDINATE SIZE AND
LOCATION WITH MECHANICAL CONTRACTOR. ROOF FRAMING
A INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB
METAL ROOF DECK WITH (2) LAYERS OF 3/4" PLYWOOD
PLAN
INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB
3/31/2021 5:23:37 PM

B METAL ROOF DECK


ROOF FRAMING PLAN
1 SCALE: 1/16" = 1'-0" C
INDICATES SPAN DIRECTION OF 3", LAMINATES SOUTHERN
PINE T&G ROOF DECKING
SHEET NUMBER
(S) INDICATES SLOPING MEMBER

S-105
S8 S7 S6
17'-3 1/4" FIELD VERIFY 17'-3 1/4" FIELD VERIFY
4'-8 3/16" 2" 5'-2 11/16" 5'-2 11/16" 3'-9"

1'-5 11/16"
5'-2 11/16" 5'-2 11/16" 3'-0 7/8"
RHIT MOENCH
DBE 132'-8 1/2" DBE 130'-6 7/16"
RENOVATION
N5 N4 T
5500 Wabash Avenue
2 3/4" 8'-4 1/4" 6" Terre Haute, Indiana
RAMP SLOPE DOWN
47803

TB 132'-5 1/2"

6'-10 1/4"
6

TB 132'-5 1/2"

TB 131'-11 5/8"
W6x12
S-503

TB 130'-7 7/8"
TB 131'-6 3/8"

TB 131'-1 1/8"

TB 130'-3 3/8"
W6x12
A Owner

W6x12

W6x12

W6x12

W6x12

W6x12
Rose-Hulman Institute of Technology
(E) W24x84 PLAN NOTES: 5500 Wabash Avenue
C W6x12
1'-4" Terre Haute, Indiana 47803

18'-8 7/8" FIELD VERIFY


6
1. SEE S000 SERIES DRAWINGS FOR GENERAL NOTES, CONCRETE TB 132'-5 1/2"

1'-8 1/8"
● HSS8x4x5/16 812-877-1511
SCHEDULES, DESIGN INFORMATION, AND LOADING CRITERIA. SIM S-502 TB 134'-3 7/8"

4'-9 15/16"
2'-9"

2. SEE DRAWING S500 FOR STRUCTURAL STEEL COLUMN BASE DBE 132'-8 1/2"
HSS12x6x5/16
PLATE AND ANCHOR ROD DETAILS.
TB 133'-0 3/8" 14 15
6"

6
S-502 S-502
W16x31 6 W6x12
S-501
TB 120'-1 3/8" TB 132'-9 7/8"

(E) 10x12

HSS12x6x5/16

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12
S-502

TB 132'-8 3/8"
RAMP SLOPE DOWN
TYP

4'-9 15/16"

(E) 10x12

(E) 10x12
TB 120'-0 7/8"

TB 120'-0 7/8"
EXISTING 10" Architect
W18x35

W18x35
CONCRETE SLAB
LEGEND W6x12 EXISTING 3" RATIO
WOOD DECKING
13'-0 3/8"

6 101 South Pennsylvania Street

2'-7 13/16"
BFX INDICATES FOOTING MARK. "B" INDICATES REQUIRED ● TB 133'-2 3/8"
BEARING CAPACITY IN KSF AND FX INDICATES BEARING MARK. SIM S-502 Indianapolis, Indiana 46204
317-633-4040

A
TF INDICATES TOP OF FOOTING ELEVATION. (E) 10x16 (E) 10x16
T/SLAB 120'-11 13/16" U

2'-2 1/8"
2'-4"
TB INDICATES TOP OF BEAM ELEVATION. Structural Engineer
INDICATES OPENING IN SLAB. COORDINATE SIZE AND W8x10 W6x12 T/DECKING 134'-3 13/16" Fink Roberts & Petrie, Inc.
LOCATION WITH MECHANICAL CONTRACTOR. TB 133'-7 3/8" 9449 Priority Way W Dr #200
4 Indianapolis, Indiana 46240

4'-9 15/16"
1'-1"

13
FV

A INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB S-503 317-872-8400

(E) 10x12
METAL ROOF DECK WITH (2) LAYERS OF 3/4" PLYWOOD S-502

INDICATES SPAN DIRECTION OF 1 1/2", 20 GAGE WIDE RIB


D B

(E) 10x12

(E) 10x12

(E) 10x12

(E) 10x12
METAL ROOF DECK W6x12 Mechanical / Electrical Engineer

9'-11"

W8x10
INDICATES SPAN DIRECTION OF 3", LAMINATED SOUTHERN
4
TB 134'-0 3/8" R.E. Dimond & Associates, Inc.

3" WOOD DECKING INFILL
C S-503 732 N Capitol Avenue

(E) 10x12
12 PINE T&G ROOF DECKING TO MATCH EXISTING
Indianapolis, Indiana 46204

(E) 10x12

(E) 10x12
S-502 INDICATES SLOPING MEMBER DBE 134'-3 13/16"
(S) 317-634-4672
(E) W8x10

W8x10
W8x10
(E) W8x10

6'-5"
2'-10" 5'-1"
FIELD VERIFY

ENLARGED PLAN - FIRST LEVEL ENLARGED PLAN - SOUTH RAMP PLAN


1 SCALE: 1/4" = 1'-0"
2 SCALE: 1/4" = 1'-0"

5.9 5.1
S3 S2
17'-3 1/4" FIELD VERIFY 14'-1" FIELD VERIFY

5'-9 1/16" 5'-9 1/16" 5'-9 1/16" EQ EQ 4.1 3.1 2.1 2'-10 5/16"
16'-10" FIELD VERIFY 17'-0" FIELD VERIFY FIELD VERIFY
FIELD VERIFY FIELD VERIFY FIELD VERIFY
W16x20 COLUMN
7 3/8" 8'-9 11/16" 6'-4 5/16" 10'-5 11/16" 4'-8 5/16" 12'-3 11/16" 2'-10 5/16"
EXTENSION, TYPICAL

HSS8x4x5/16 (S) HSS8x4x5/16 (S)


(E) 10x16 J HSS5x5x5/16 HSS5x5x5/16 TYP HSS5x5x5/16 HSS5x5x5/16
U
1 3

S-501 S-501
3'-3 1/2" 4'-1 7/8"
5'-11 5/8"

HSS8x6x1/2 TB 149'-9"
HSS8x6x1/2 TB 149'-9"

HSS6x4x1/4
TB 153'-6"
W6x16 TB 149'-7" W6x16 TB 149'-7" W6x16 TB 149'-7"
EQ

W8x10 W8x10

EQ
17'-8 1/4" FIELD VERIFY

18'-0" FIELD VERIFY


W8x10

W8x10
2'-6"

12'-8" FIELD VERIFY


HSS8x4x5/16 (S) HSS8x4x5/16 (S)

W6x16 (S)

W6x16 (S)

W6x16 (S)
W6x16 (S)
W8x10 W8x10 2 W6x16 W6x16 W6x16
S-501

T/DECKING 134'-3 13/16"


(E) 10x12

(E) 10x12

(E) 10x12
(E) 10x12

B
HSS6x4x1/4

EQ
TB 153'-6"
EQ

EXISTING 3"
WOOD DECKING (E) W12x19 W/ (E) C8x11.5 TB 146'-7 11/16" FV (E) W12x19 W/ (E) C8x11.5 TB 146'-7 11/16" FV (E) W12x19 W/ (E) C8x11.5 TB 146'-7 11/16" FV SEAL | DATE 04/01/21

(E) 10x16 HSS8x4x5/16 (S) HSS8x4x5/16 (S)


V K
(E)W8X18 (E)W8X18 (E)W8X18 (E)W8X18

S4 S3 S2

SHEET ISSUE
1 Construction Documents 04/01/21
ENLARGED PLAN CENTRAL MONITOR TYPICAL BAY SOUTH MONITOR PLAN
3 4 5 SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"

S6 5.9 5.1 S5 5.9 5.1


1'-5 11/16" 1'-8 9/16" 14'-1" (FV)
14'-1"
(FV) (FV)
FIELD VERIFY
9.8 8.9 7.9
HSS8x6x1/2

HSS6x4x1/4

HSS8x6x1/2

17'-5 13/16" (FV) 16'-7 1/2" (FV)


HSS8x6x1/2

HSS6x4x1/4

HSS8x6x1/2

16
7'-0" 7'-0" 7'-0" 7'-0" 2'-6 1/2"
EXISTING S-502
HSS8x4x5/16 (S) HSS8x4x5/16 (S) MASONRY WALL 3/4" DIA. HANGER
ROD, TYP
9"

HSS8x4x1/2 (S) HSS8x4x1/2 (S)


T G
HSS8x6x1/2

HSS6x4x1/4

HSS8x6x1/2

C4x4.5 C4x4.5 (S) C4x4.5 (S) C4x4.5 (S)


2
(E) C9x13.4

(E) C9x13.4

(E) C9x13.4

(E) C9x13.4

(E) C9x13.4
12 12
5'-3"

● ●
S-503
S-502 S-502
SIM SIM
G

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


ENLARGED PLAN ENLARGED PLAN ENLARGED PLAN - ROOF FRAMING SHEET TITLE
6 7 SCALE: 1/4" = 1'-0" 8
SCALE: 1/4" = 1'-0" SCALE: 1/8" = 1'-0"
ENLARGED PLANS
3/31/2021 5:43:50 PM

SHEET NUMBER

S-200
CENTERLINE OF
GIRDER

1 1/2" (MIN)
(2) HEAVY HEX NUTS
RHIT MOENCH

6" THREADS AND


RENOVATION

PROJECTION
AND 3/8" x 3" x 3" A572 GR 50
PLATE WASHERS
1'-2"
TOP OF FOUNDATION
ANCHOR RODS WITH DOUBLE 2" 5" 5" 2" 5500 Wabash Avenue
SEE PLAN FOR
COLUMN AND
NUTS AND PLATE WASHERS FOR
LEVELING. SEE BASE PLATE DETAILS FOR
ANCHOR ROD LAYOUT. CLEAN OIL FROM
1/4 (2) ANGLES Terre Haute, Indiana
BASE PLATE
47803

2"
ASTM F1554 GR36 ANCHOR RODS PRIOR TO INSTALLATION
1" DIAMETER INFORMATION
NOTE: CLIP PLATE WASHERS

5"
ANCHOR ROD

1'-0"
FINISHED COLUMN END IF NECESSARY TO CLEAR

1'-2"
SEE PLAN FOR COLUMN
Owner
TOP OF CONCRETE Rose-Hulman Institute of Technology

5"
HEAVY HEX NUT ELEVATION
2" NON-SHRINK GROUT 5500 Wabash Avenue

2"
FOR 1" ANCHOR RODS Terre Haute, Indiana 47803
NOTES: 812-877-1511
3" NON-SHRINK GROUT 1" THICK A572 GR50
FOR 1 1/2" ANCHOR RODS BASE PLATE
TACK WELD (BRACED BAYS) SEE FOUNDATION 1. DESIGN CONNECTION AS STANDARD AISC SIMPLE DOUBLE ANGLE UNLESS SPECIFICALLY
PLAN FOR ANCHOR HSS6x6 DETAILED OTHERWISE.
ROD INFORMATION PER PLAN
2. CONTRACTOR HAS OPTION TO BOLT OR WELD ANGLES UNLESS SPECIFICALLY DETAILED
OTHERWISE.
NOTE:
NOTE: PROVIDE HOT DIP GALVANIZED ASSEMBLIES WHERE PROJECTED 3. CONNECTION DEPTH SHALL BE AT LEAST 2/3 x BEAM T-DIMENSION.
PORTION IS EXPOSED TO EXTERIOR OR UNCONDITIONED ATMOSPHERE.
1. PROVIDE 1 13/16" DIA HOLES FOR 1" DIA ANCHOR RODS
4. SAME APPLIES FOR TYPICAL BEAM TO COLUMN CONNECTION

Architect
RATIO
TYPICAL ANCHOR ROD DETAIL TYPICAL COLUMN BASE DETAIL TYP BASE PLATE DETAIL TYPICAL BEAM TO GIRDER CONNECTION 101 South Pennsylvania Street
1 NOT-TO-SCALE
2 NOT-TO-SCALE
3 NOT-TO-SCALE
4 NOT-TO-SCALE
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


e 36/4 PATTERN AT
DESIGN BOLT GROUP ALL END LAP SUPPORT R.E. Dimond & Associates, Inc.
FOR VERTICAL REACTION POINTS AND BUILDING 732 N Capitol Avenue
PERIMETER (ONE
AND MOMENT DUE TO "e" Indianapolis, Indiana 46204
STEEL JOIST OR BEAM ATTACHMENT PER 6"
PARALLEL TO 317-634-4672
PER PLAN
SEE NOTE 3 - TYP DECK SPAN)
L3 1/2 x 3 1/2 x 3/8
(TYPICAL)
T/EXISTING DECKING
HSS COLUMN PER PLAN
SEE PLANS FOR (2) SIDELAP CONNECTIONS
SIZE (SEE CAP (HILTI S-SLC-01 FASTENERS)
PLATE DETAIL BETWEEN EACH SUPPORT
AT TOP OF OPENING TYPICAL (MAX SPACING 36")
COLUMN

2"
3"
SEE FRAMING PLAN
FOR BEAM SIZE AND PROVIDE ANGLE FRAME AS
REACTION VALUES INDICATED UNLESS MEMBER
SIZES ARE GIVEN ON PLAN. TH
FOR SQUARE AND RECTANGULAR HSS ID M
BEAM PER PLAN 36/4 PATTERN AT ALL W MU
PROVIDE WT OR END SHEAR PLATE T I
. NOTES: INTERMEDIATE SUPPORTS
H EE A X
DESIGN WELD TO HSS COLUMN FOR (2) L4x4x5/16 x 7" LONG JOIST OR BEAM SPACING PER PLAN S 6" M
VERTICAL REACTION WITH ECCENTRICITY STRIP BOTTOM END LAPS SHALL OCCUR ONLY AT SUPPORT POINTS. 3
1.
OF HALF THE HSS DIMENSION FLANGE AS REQUIRED
2. SUPPORTS MAY BE WIDE FLANGE BEAMS, STEEL JOIST OR COLD FORMED
PROVIDE CONNECTION DEPTH TO PREVENT (2) 1/2" DIAMETER x 6" LONG NOTES: LIGHT GAGE METAL FRAMING (WIDE FLANGE CONDITION SHOWN).
PLASTIFICATION OF HSS WALL BASED ON VERTICAL LAG SCREWS, EACH SIDE
REACTION TIMES HALF OF HSS DIMENSION 1. PROVIDE ANGLE FRAME FOR OPENINGS 12" SQUARE OR LARGER. 3. FASTEN THRU MULTIPLE SHEETS AT ALL ENDS AND SIDE LAPS.
EXISTING TIMBER BEAM
OR GIRDER PER PLAN 2. COORDINATE SIZE AND LOCATION OF OPENINGS WITH MECHANICAL CONTRACTOR 4. DECK UNITS SHALL BE CONTINUOUS OVER AS MANY SPANS
PRIOR TO FABRICATION. AS THE STRUCTURAL STEEL LAYOUT WILL PERMIT.

3. FOR FRAME ANGLE BEARING LOCATIONS ON STEEL JOISTS THAT DO NOT OCCUR 5. USE HILTI X-HSN 24 FASTENERS AT JOIST AND X-ENP-L15 AT WIDE FLANGE BEAMS, PLATES
AT PANEL POINTS, SEE "TYPICAL JOIST AND DECK REINFORCING DETAIL" FOR AND ANGLES 1/4" THICK OR GREATER AND #10 SCREWS AT COLD FORMED METAL FRAMING SUPPORTS.
REINFORCING REQUIREMENTS.

TYPICAL BEAM TO HSS COLUMN SHEAR


CONNECTION TYPICAL STEEL CONNECTION INTO TIMBER FRAMING TYPICAL ROOF DECK OPENING TYPICAL ROOF DECK FASTENING - HILTI FASTENERS
5 NOT-TO-SCALE 6 7 NOT-TO-SCALE
8 SCALE: 1" = 1'-0"
SCALE: 1 1/2" = 1'-0"

SEE PLAN 3/16 2-12 SEAL | DATE 04/01/21

2" MIN
METAL ROOF
DECK
3"

1/4" BENT PLATE


CONTINUOUS
BEAM PER PLAN

SHEET ISSUE
1 Construction Documents 04/01/21
NOTES:

1. LOCATION OF BENT PLATE EDGE SHALL BE ADJUSTED IN FIELD TO


WITHIN AISC TOLERANCES FOR ADJUSTABLE ITEMS (+/- 3/8") FROM
THEORETICAL CENTERLINE OF BEAM (NOT ERECTED CENTERLINE
OF BEAM). AT ELEVATOR SHAFTS LOCATE WITHIN (+/- 1/2") FROM
INTERIOR OF SHAFT.

TYPICAL ROOF DECK EDGE DETAIL


9 SCALE: 1" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

TYPICAL
STRUCTURAL STEEL
DETAILS
3/31/2021 5:23:40 PM

SHEET NUMBER

S-500
5.9 5.1 5.9 5.1

EQ
14'-1" FIELD VERIFY
EQ EQ
14'-1" FIELD VERIFY
EQ
RHIT MOENCH
RENOVATION
2 2
5500 Wabash Avenue

S
S-502
TB 153'-8 1/16"
TB 153'-6"
S-502 TB 153'-8 1/16"
TB 153'-6"
Terre Haute, Indiana
3" WOOD T&G ROOF DECKING 3" WOOD T&G ROOF DECKING
47803
2x SOUTHERN PINE NAILER 2x SOUTHERN PINE NAILER
Owner
Rose-Hulman Institute of Technology
12'-8" FIELD VERIFY 5500 Wabash Avenue
3/4" DIA. BAR WITH CLEVIS 3/4" DIA. BAR WITH CLEVIS
AT EA END, TYP AT EA END, TYP Terre Haute, Indiana 47803
812-877-1511
4
S-502
3 TB 149'-9" 3 TB 149'-9"

S-502 S-502

07 ROOF LEVEL 1 07 ROOF LEVEL


1/2" GUSSET 148'-10 1/2" ● 1/2" GUSSET 148'-10 1/2"
1 S-502
S-502 BAR ASSEMBLIES MUST CONT. L6x4x3/8 LLH, EA SIDE BAR ASSEMBLIES MUST CONT. L6x4x3/8 LLH, EA SIDE
BE ERECTED PRIOR TO
(SIM) BE ERECTED PRIOR TO
DECKING INSTALLATION DECKING INSTALLATION T/EXISTING STEEL Architect
EL = 146'-7 11/16" (FV)
RATIO
3" DIAMETER HOLE FOR 3" DIAMETER HOLE FOR 101 South Pennsylvania Street
SPRINKLER PIPING, SPRINKLER PIPING, Indianapolis, Indiana 46204
COORDINATE LOCATION COORDINATE LOCATION
WITH PLUMBING CONTRACTOR WITH PLUMBING CONTRACTOR 10 317-633-4040
S-502
Structural Engineer
Fink Roberts & Petrie, Inc.
TB 143'-10" TB 143'-10"
T/EXISTING STEEL 9449 Priority Way W Dr #200
7 7

EL = 143'-1 7/16" (FV) Indianapolis, Indiana 46240
S-501 S-501 317-872-8400
OPP. HAND
CONT. HSS5x5x3/8, EA SIDE CONT. HSS5x5x3/8, EA SIDE
Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
FULL PEN SPLICE WELD 317-634-4672

CENTRAL MONITOR SECTION AT COLUMN CENTRAL MONITOR INTERMEDIATE SECTION MONITOR SOUTH SECTION
1 SCALE: 1/2" = 1'-0"
2 SCALE: 1/2" = 1'-0"
3 SCALE: 1/2" = 1'-0"

N1
FIELD
T FIELD
VERIFY VERIFY

N10 9
04 SECOND LEVEL S-502 06 SOUTH SECOND LEVEL
SEE ARCHITECTURAL 130'-6 13/32" 134'-3 13/16"

4" (FV) 1'-2 1/2" (FV)


EXISTING MASONRY WALL

03 FIRST LEVEL
120'-11 13/16"
L6x6x1/2x7'-0 1/2" EA SIDE;
4" MINIMUM BEARING EA. END

5
EXISTING MASONRY WALL
S-502

L8x8x1/2x10'-8" EA SIDE;
4" MINIMUM BEARING EA. END
7'-1 1/2" AFF

1/2" 1/2" 8
S-501
3/16 SEAL | DATE 04/01/21
5 3/8" x 6'-4" PLATE

S-501 (FIELD VERIFY WIDTH)

(SIM) 3/8" x 9'-11 1/2" PLATE


(FIELD VERIFY WIDTH)
6'-11 1/2"

SECTION SECTION
NEW CONCRETE RAMP, #4 x 1'-0" LONG
5 SCALE: 1" = 1'-0"
6 SCALE: 3/4" = 1'-0"
1" MINIMUM THICKNESS; DOWEL AT 12" OC,
SEE ARCHITECTURAL EMBED 4" SHEET ISSUE
1 Construction Documents 04/01/21

02 LOWER LEVEL 1
4"

110'-7 1/16"
T
1'-1" (FV)
5.9
9" TOP OF RAMP
VARIES SEE PLAN

1/4 6 1/2" TOP OF BEAM


1/4 EXISTING PER PLAN
MASONRY WALL
T/STEEL
EL = 143'-10" L3x3x1/4 x 0'-8" LONG
1/4
SECTION HSS5x5x3/8
4 SCALE: 1/2" = 1'-0" CONTINUOUS

L4x4x3/8 x 0'-8" LONG


1/4
BEAM PER PLAN

1/2"x6" x 0'-8" BEARING PLATE


NEW W6x20 COLUMN w/ (2) 1/2" DIAMETER x 4" LONG
1/4 EXTENSION HEADED STUDS

GROUT CELL(S) A MINIMUM OF


24" BELOW BEAM BEARING
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


DETAIL DETAIL
7 8 SCALE: 1 1/2" = 1'-0"
SHEET TITLE
SCALE: 1 1/2" = 1'-0"
STRUCTURAL STEEL
SECTIONS AND
DETAILS
3/31/2021 5:48:33 PM

SHEET NUMBER

S-501
5.9 1/4

WOOD DECKING
S RHIT MOENCH
RENOVATION
WOOD DECKING 1'-0"
3 SIDES, TYP PER PLAN
PER PLAN
1/4
2x NAILER
2x NAILER 3/16 2-12
WP
3 SIDES,
TYP 1/4 3/4" DIAMETER ROD
5500 Wabash Avenue
3/4" DIAMETER ROD CJP WELD,
1/4 2-12 w/ # 2 1/2" CLEVIS GRIND SMOOTH
w/ # 2 1/2" CLEVIS, TYP
1 1/2" METAL Terre Haute, Indiana

3"
L6x4x3/8 (LLH) ROOF DECK

1 1/2"
CONTINUOUS
1/2" GUSSET PLATE
47803
1/4" BENT PLATE
CONTINUOUS Owner
BOTT/ANGLE L3x3x5/16 x 0'-4" LONG,
EL = 149'-2" 3 SIDES, EACH SIDE Rose-Hulman Institute of Technology
1/4 TYP 1/4 5500 Wabash Avenue
1/2" GUSSET PLATE 1/2" GUSSET PLATE COLUMN BEAM PER
EACH SIDE 1/2" GUSSET PLATE
Terre Haute, Indiana 47803
PER PLAN PLAN, TYP 812-877-1511
1/4" CLOSURE PLATE
NEW W6 COLUMN 3/4" DIAMETER ROD
EXTENSION 1/2" CAP PLATE 1/4 w/ # 2 1/2" CLEVIS

NOTE: ALL VISIBLE STEEL AND CONNECTIONS TO BE AESS CATEGORY 3. NOTE: ALL VISIBLE STEEL AND CONNECTIONS TO BE AESS CATEGORY 3. NOTE: ALL VISIBLE STEEL AND CONNECTIONS TO BE AESS CATEGORY 3.

MONITOR CONNECTION DETAIL MONITOR CONNECTION DETAIL MONITOR CONNECTION DETAIL MONITOR CONNECTION DETAIL
1 SCALE: 1" = 1'-0"
2 SCALE: 1" = 1'-0"
3 SCALE: 1 1/2" = 1'-0"
4 SCALE: 1" = 1'-0"
Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
S8

EXISTING 3" WOOD Structural Engineer


DECKING Fink Roberts & Petrie, Inc.
5.9 9449 Priority Way W Dr #200
06 SOUTH SECOND LEVEL Indianapolis, Indiana 46240
TB 133'-0 5/16" 134'-3 13/16" 1/4 317-872-8400
WOOD DECKING
PER PLAN CONT. C6x8.2 (SLOPES)

2"
EXISTING TIMBER
(2) - 1/2" Ø LAG BEAM PER PLAN Mechanical / Electrical Engineer
2x NAILER 3 SIDES, TYP
SCREWS EACH SIDE

3"
1/4 R.E. Dimond & Associates, Inc.
HSS12x6 PER PLAN 732 N Capitol Avenue
DECKING
PER PLAN
1/4 2-12 Indianapolis, Indiana 46204
WP 3/4" DIAMETER ROD
3/8" TAB PLATE 317-634-4672
w/ # 2 1/2" CLEVIS 3/16
1/4 T/BEAM VARIES, L6x4x3/8 (LLH)
(2) - L3x3x5/16 HSS4x4x5/16 AT 4'-0" OC MAX
BEAM SEE PLAN CONTINUOUS
PER PLAN TB VARIES, SEE PLAN 1/2" GUSSET PLATE
3/16
BOTT/ANGLE
EL = 149'-2" 1/4 04 SECOND LEVEL
EACH SIDE 130'-6 13/32"
1/4 1/2" GUSSET PLATE
EACH SIDE
2L3x3x5/16 HANGER 1/2"x5"x0'-10" PLATE
BEAM PER PLAN 1/4" CLOSURE PLATE
(2) - 1/2" DIA. HILTI KH-EZ
SCREW ANCHORS,
2" EMBED, 7" GA
NOTE: ALL VISIBLE STEEL AND CONNECTIONS TO BE AESS CATEGORY 3.

SECTION SECTION SECTION SECTION


5 SCALE: 1 1/2" = 1'-0"
6 SCALE: 1 1/2" = 1'-0"
7 SCALE: 1" = 1'-0"
8 SCALE: 1" = 1'-0"

D
1'-1" (FV)
S6

EXISTING
MASONRY WALL
EACH SIDE
3/16
EXISTING 3" WOOD DECKING EXISTING
L3x3x5/16 x 0'-6" WITH 1/4" 10" SLAB
STIFFENER CENTERED

EXISTING WOOD FLOOR DECKING

L4x4x5/16 x 0'-6" 6" MIN TOP OF BEAM


(EACH SIDE AT PER PLAN
06 SOUTH SECOND LEVEL 1/4 EXISTING TIMBER BEAM
134'-3 13/16" OTHER COLUMNS)
1/4
EL 146'-7 11/16"
FIELD VERIFY
2"

1/2" END PLATE 1/4


3"

4"
BEAM PER PLAN 1/4
(2) - 1/2"x4" LAG SCREWS 5/16" x 0'-6" BENT PLATE 4"
SEAL | DATE 04/01/21
L4x4x3/8x0'-8", EA SIDE

EXISTING W12x19 WITH


C8x11.5 HAT CHANNEL BEAM PER PLAN
EXISTING TIMBER BEAM 1/4
1/2"x6" x 0'-8" BEARING PLATE
w/ (2) 1/2" DIAMETER x 4" LONG
EXISTING W8x18 HEADED STUDS
STUB COLUMN
GROUT CELL(S) A MINIMUM OF
24" BELOW BEAM BEARING

SHEET ISSUE
DETAIL DETAIL SECTION SECTION 1 Construction Documents 04/01/21
9 SCALE: 1 1/2" = 1'-0"
10 SCALE: 1 1/2" = 1'-0"
11 SCALE: 1" = 1'-0"
12 SCALE: 1" = 1'-0"

EXISTING
WOOD DECKING
(2) 3/4" DIAMETER EXISTING
THRU BOLTS WOOD DECKING
(2) 3/4" DIAMETER
1"

THRU BOLTS
3" 2" 3"
1 1/2"
3"

3" 2" 3"


EXISTING 3" 1/4
4"

WOOD DECKING

06 SOUTH SECOND LEVEL WOOD DECKING


4"

1/2" U SEAT PLATE,


134'-3 13/16" FIELD VERIFY PER PLAN
REQUIRED WIDTH
3" 3"

1/2" U SEAT PLATE,


1"

BEAM FIELD VERIFY


L7x4x3/8 x 0'-8" LONG, PER PLAN REQUIRED WIDTH
EACH SIDE
BEAM
(2) 1/2" DIAMETER x 6" LONG PER PLAN
LAG SCREWS, EACH SIDE
1/2" CAP PLATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE

1 1/2"
2x NAILER AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
HSS6x6 COL
3 SIDES COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
3/16
PER PLAN
2x NAILER PROJECT NO. 19040.000
1/4
L5x3x5/16 (LLV)
BEAM SHEET TITLE
PER PLAN

COLUMN
1/4 HSS3x3x1/4 x 0'-10 1/4" LONG
AT 3'-0" OC
STRUCTURAL STEEL
PER PLAN
SECTIONS AND
1/4
DETAILS
3/31/2021 5:43:57 PM

SECTION SECTION SECTION SECTION


13 SCALE: 1" = 1'-0"
14 SCALE: 1" = 1'-0"
15 SCALE: 1" = 1'-0"
16 SCALE: 1" = 1'-0" SHEET NUMBER

S-502
G
5'-0"

5
RHIT MOENCH

S-503 RENOVATION
S8 5500 Wabash Avenue
(FV) (FV) Terre Haute, Indiana
8.9
(4) 1/2" DIAMETER x 6" LONG
47803
LAG SCREWS, 6" GAGE
5.1 Owner
EXISTING C9 DECKING
PURLIN PER PLAN 06 SOUTH SECOND LEVEL
Rose-Hulman Institute of Technology
PER PLAN 3 SIDES, TYP 134'-3 13/16" 5500 Wabash Avenue

EXISTING
3/16

MATCH
Terre Haute, Indiana 47803

20'-3"
C4 PER PLAN 812-877-1511

2"
EXISTING C9
PURLIN

2"
04 SECOND LEVEL

3"
PER PLAN

6 1/2"
130'-6 13/32" 1/4
EXISTING TIMBER
BEAM PER PLAN

3/8" TAB HILTI X-U FASTENER AT 4" OC


3/8" TAB PLATE
PLATE C12 INFILL PER PLAN;
FIELD MEASURE REQUIRED LENGTH BEAM PER PLAN
02 LOWER LEVEL 1 Architect
3/4" DIAMETER
110'-7 1/16" 3/8" TAB PLATE RATIO
HANGER ROD
3/8" x 9" x 1'-0" PLATE 101 South Pennsylvania Street
3/16 Indianapolis, Indiana 46204
1/4 317-633-4040
3/4" DIAMETER
3/16
HANGER ROD Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
SECTION SECTION SECTION SECTION
1 SCALE: 3/4" = 1'-0"
2 SCALE: 1 1/2" = 1'-0"
3 SCALE: 1" = 1'-0"
4 SCALE: 1 1/2" = 1'-0" Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

03 FIRST LEVEL
120'-11 13/16"

EXISTING 10"
CONCRETE SLAB
3/4" DIAMETER ROD

1/2" x 3" x 0'-3" PLATE

2" MIN

3/16

20'-3" AFF
BEAM PER PLAN
MC6, CAP EACH
END WITH 1/4" PLATE (2) CLIP ANGLE CONNECTION,
REMOVE CONCRETE
ENCASEMENT AS REQUIRED TO
FACILITATE CONNECTION.

EXISTING BEAM PER PLAN

DETAIL SECTION
5 SCALE: 1 1/2" = 1'-0"
6 SCALE: 1" = 1'-0"

SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19040.000


SHEET TITLE

STRUCTURAL STEEL
SECTIONS AND
DETAILS
3/31/2021 5:48:38 PM

SHEET NUMBER

S-503
ABBREVIATIONS ARCHITECTURAL MATERIAL LEGEND
A F M T
A/C AIR CONDITIONING F-R FIRE RESISTIVE MAX. MAXIMUM T. THICKNESS
GENERAL ARCHITECTURAL NOTES
FINISHED WOOD
ACOUS.
A.C.T.
ACP
ACOUSTICAL
ACOUSTICAL CEILING TILE
ACOUSTICAL CEILING PANEL
FAB.
F.C.U.
F.D.
FABRICATE/FABRICATOR
FAN COIL UNIT
FLOOR DRAIN
MB.
M.C.
M.D.F.
MARKER BOARD
MECHANICAL CONTRACTOR
MEDIUM DENSITY FIBERBOARD
T.B.
TBD
T.C.
TACK BOARD
TO BE DETERMINED
TOP OF CURB
EARTH SHOWN CUT AND ELEVATION ACOUSTICAL CEILING TILE
A. THESE GENERAL NOTES APPLY TO ARCHITECTURAL
DRAWINGS.
RHIT MOENCH
ADA
ADAAG
AMERICANS W/DISABILITIES ACT
AMERICANS W/DISABILITIES
ACCESSIBILITY GUIDELINES
F.E.
F.E.C.
F.F.E.
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR ELEVATION
MECH.
M.E.P.
MFR.
MECHANICAL
MECH./ELECT./PLUMBING
MANUFACTURER(ING)
T.D.
TECH.
TEL.
TOP OF DECK
TECHNICAL
TELEPHONE
GRANULAR FILL ENGINEERED WOOD: GLUE
LAMINATED
RESINOUS FLOORING:
TERRAZO, TROWEL-ON, UNO
B. WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID
UNLESS SPECIFICALLY NOTED TO BE BY ALTERNATE BID.
C. FIELD VERIFY EXISTING FINISH FLOOR ELEVATIONS PRIOR TO
RENOVATION
SAND, GROUT WOOD FLOOR, WOOD TILE: CERAMIC, QUARRY, UNO STARTING CONSTRUCTION. MATCH NEW FLOOR ELEVATIONS
ADJ.
A/E
ADJUSTABLE
ARCHITECT/ENGINEER
F.F.&E. FURNISHINGS, FIXTURES AND
EQUIPMENT
M.H.
MIN.
MANHOLE
MINIMUM
TEMP.
T&G
TEMPORARY
TONGUE AND GROOVE
AS NOTED SHINGLES, OR SIDING WITH EXISTING UNLESS NOTED OTHERWISE.
D. DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FINISH
5500 Wabash Avenue
CAST-IN-PLACE CONCRETE PARTICLEBOARD CARPET, CARPET TILE (DETAIL)
A.F.F.
ALT.
ABOVE FINISHED FLOOR
ALTERNATE
F.H.C.
FIN.
FIRE HOSE CABINET
FINISH(ED)
MISC.
M.O.
MISCELLANEOUS
MASONRY OPENING
T.M.
TMPRD.
TOP OF MASONRY
TEMPERED
SURFACE. DIMENSIONS TO NEW CONSTRUCTION ARE TO
STRUCTURAL CENTERLINE, FACE OF CONCRETE OR Terre Haute, Indiana
MASONRY CONSTRUCTION, OR TO FACE OF FINISH UNLESS
ALUM.
A.P.
ALUMINUM
ACCESS PANEL
FLR.
FLUOR.
FLOOR
FLUORESCENT
MTL. METAL T/O
T.P.
TOP OF
TOP OF PAVEMENT
PRECAST CONCRETE, CAST
STONE
PLYWOOD GRATING
SHOWN IN PLAN NOTED OTHERWISE. FIELD VERIFY ALL CONDITIONS AND
DIMENSIONS PRIOR TO STARTING WORK AND NOTIFY
47803
ARCH. ARCHITECT/ARCHITECTURAL F/O FACE OF N T.S. TOP OF STEEL CONCRETE MASONRY UNIT GLASS FIBER REINFORCED GRATING ARCHITECT IMMEDIATELY IF DISCREPANCIES ARE FOUND
A.V. AUDIO/VISUAL F.O. FINISH OPENING N.A.F. NO APPLIED FININSH T.W. TOP OF WALL CONCRETE SIDING OR TRIM BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD Owner
F.O.B. FACE OF BLOCK N.I.C. NOT IN CONTRACT TYP. TYPICAL CONDITIONS. Rose-Hulman Institute of Technology
BRICK MASONRY EIFS INSULATED GLASS: E. DO NOT SCALE DRAWINGS. REFER DIMENSION QUESTIONS
B F.O.BR. FACE OF BRICK NO. NUMBER 5500 Wabash Avenue
(SMALL SCALE) TO ARCHITECT FOR INTERPRETATION.
BD. BOARD F.O.C. FACE OF CONCRETE N.T.S. NOT TO SCALE U STONE: LIMESTONE, Terre Haute, Indiana 47803
F. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE
BITUM. BITUMINOUS F.O.F. FACE OF FINISH U.N.O. UNLESS NOTED OTHERWISE GRANITE, MARBLE OR AS SPRAYED FIREPROOFING INSULATED GLASS: ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS, A 812-877-1511
BLDG. BUILDING F.O.G. FACE OF GYPSUM BD. NOTED SHOWN ON ROLLED SHAPE (DETAIL) SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E., A101-B.
O UTIL. UTILITY
B/O BOTTOM OF F.O.S. FACE OF STUD O.A. OVER ALL U.V. UNIT VENTILATOR TERRA COTTA, STRUCTURAL BATT INSULATION: THERMAL MEMBRANE: WATERPROOF, G. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES
B.O.W. BOTTOM OF WALL FPRF. FIREPROOF CLAY TILE OR ACOUSTICAL, UNO ROOF, DAMPPROOFING FROM FINISH FACE OF ADJACENT WALLS UNLESS NOTED
O.C. ON CENTER
OTHERWISE.
BSMT. BASEMENT FT. FOOT/FEET O.D. OUTSIDE DIAMETER V
METAL: TYPE AS NOTED RIGID INSULATION: THERMAL, AIR BARRIER SYSTEM H. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND
F.V. FIELD VERIFY O.F.C.I. OWNER FURNISHED-CONTRACTOR V.C.T. VINYL COMPOSITION TILE SUPPLIERS TO INSURE PROPER ROUGH-IN CLEARANCES FOR
ACOUSTICAL, OR SAFING
C INSTALLED VERT. VERTICAL INSTALLATION, USE AND MAINTENANCE.
CAB. CABINET G O.F.O.I. OWNER FURNISHED-OWNER VEST. VESTIBULE METAL: ROLLED SHAPES GYPSUM WALL BOARD I. PROTECT EXISTING SURFACES TO REMAIN THAT ARE NOT
C.F.C.I. CONTRACTOR GA. GAUGE INSTALLED INCLUDED IN SCOPE OF WORK BUT THAT ARE WITHIN AREAS
VIF VERIFY IN FIELD
FURNISHED-CONTRACTOR INSTALLED O.H. OPPOSITE HAND OF CONSTRUCTION ACTIVITY.
G.C. GENERAL CONTRACTOR WOOD FRAMING / BLOCKING: PLASTER ON METAL LATH J. PATCH, REPAIR AND RESTORE EXISTING FINISHES AND
C.G. CORNER GUARD GEN. GENERAL OPG. OPENING W CONTINOUS SURFACES TO AS NEW CONDITION AS REQUIRED TO MATCH Architect
C.I.P. CAST-IN-PLACE GL. GLASS OPP. OPPOSITE W WIDE/WIDTH SURROUNDING MATERIALS OR TO PROVIDE APPROPRIATE
C.J. CONTROL JOINT G.W.B./ GYPSUM WALL BOARD
WOOD SHIM SHEATHING: GYPSUM, OR AS
SUBSTRATE PRIOR TO INSTALLING NEW FINISHES. AREAS
RATIO
W/ WITH NOTED
CL. CENTERLINE GWB P NOTED TO BE PATCHED OR REPAIRED ON THE DRAWINGS 101 South Pennsylvania Street
W.C. WATER CLOSET
CLG. CEILING P.L. PROPERTY LINE ARE GIVEN FOR REFERENCE AND SHALL NOT BE Indianapolis, Indiana 46204
WD. WOOD
CLR CLEAR(ANCE) H P. LAM PLASTIC LAMINATE NOTE: PATTERNS SHOWN REPRESENT CUT MATERIALS IN
INTERPRETED TO LIMIT THE SCOPE OF WORK. 317-633-4040
W.H. WATER HEATER K. VERTICAL COURSING FOR NEW MASONRY WALL
C.M CONSTRUCTION MANAGER H. HEIGHT PLAS. PLASTER W/O WITHOUT PLAN OR SECTION, UNLESS NOTED OTHERWISE ABOVE. CONSTRUCTION SHALL EQUAL EIGHT INCHES (8") FOR ONE
CMP COMPOSITE METAL PANEL HB HOSE BIBB PR. PAIR WT. WEIGHT CONCRETE MASONRY UNIT PLUS ONE MORTAR JOINT AND Structural Engineer
C.M.U. CONCRETE MASONRY UNIT HDWR. HARDWARE PREFAB. PREFABRICATED W.W.F. WELDED WIRE FABRIC THREE BRICK COURSES PLUS THREE MORTAR JOINTS,
COL. COLUMN H.M. HOLLOW METAL PT. BD. PARTICLE BOARD UNLESS NOTED OTHERWISE. Fink Roberts & Petrie, Inc.
CONC. CONCRETE HORIZ. HORIZONTAL PTD. PAINTED ARCHITECTURAL SYMBOLS LEGEND L. TOOTH NEW MASONRY INTO EVERY OTHER COURSE OF
EXISTING MASONRY UNLESS OTHERWISE INDICATED.
9449 Priority Way W Dr #200
CONST. CONSTRUCTION HT. HEIGHT PWD. PLYWOOD Indianapolis, Indiana 46240
MISCELLANEOUS PROVIDE HORIZONTAL ANCHORS BETWEEN NEW AND
CONT. CONTINUOUS HVAC. HEATING, VENTILATION & A.C. EXISTING MASONRY AT CONDITIONS THAT PROHIBIT 317-872-8400
ANGLE
CONTR. CONTRACTOR H.W. HOT WATER Q TOOTHED-TYPE CONSTRUCTION. HORIZONTAL JOINTS OF
CONTRACTOR CENTER LINE NEW MASONRY SHALL MATCH EXISTING UNLESS OTHERWISE
Q.T. QUARRY TILE
COOR. COORDINATE # NUMBER INDICATED. NEW MASONRY BOND SHALL MATCH EXISTING
I COLUMN GRIDS Mechanical / Electrical Engineer
CPT. CARPET PARTITION TYPE SYMBOL* UNLESS OTHERWISE INDICATED.
I.D. INSIDE DIAMETER R R.E. Dimond & Associates, Inc.

101
A EXISTING DOOR / DOOR NUMBER M. PROVIDE CONTROL JOINTS (C.J.) IN MASONRY
C.T. CERAMIC TILE INCAN. INCANDESCENT R RADIUS CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, 732 N Capitol Avenue
C.W. COLD WATER INFO. INFORMATION R.C.P. REFLECTED CEILING PLAN 1 NEW M8A.D.2.A *REFER TO INTERIOR PARTITION LEGEND PROVIDE MAXIMUM SPACING BETWEEN VERTICAL JOINTS OF Indianapolis, Indiana 46204
INSUL. INSULATION R.D. ROOF DRAIN S2A.P 30'-0” AND MAXIMUM DISTANCE BETWEEN OUTSIDE CORNERS
CT-1 AND JOINTS OF 8'-0”. PROVIDE JOINTS BETWEEN INTERIOR
317-634-4672
D INT. INTERIOR REF. REFERENCE KEY NOTE (SHAPE VARIES)
D.E.F.S. DIERCT EXTERIOR FINISH SYSTEM ELEVATION DATUM LOAD BEARING AND NON-LOAD BEARING PARTITIONS, AT ALL
REFL. REFLECTED
REFERENCE ABRUPT CHANGES IN WALL HEIGHT, AT CHANGES IN
DEPT. DEPARTMENT J REINF. REINFORCED PARTITION THICKNESS AND AT PILASTER LOCATIONS. VERIFY
DET. DETAIL JAN. JANITOR RESIL. RESILIENT FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR
W10 WINDOW NUMBER
D.F. DRINKING FOUNTAIN J.C. JANITOR CLOSET R.H. RIGHT HAND TO STARTING WORK.
DIA. DIAMETER JST. BRG. JOIST BEARING RM ROOM 1 N. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD WALL
DIM. DIMENSION JT. JOINT R.O. ROUGH OPENING A101 ENLARGED DRAWING REFERENCE CONSTRUCTION AS INDICATED. WHERE NOT SHOWN,
DISP. DISPENSER
-

ALIGN DESIGNATED PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 32'-0”.


SURFACES VERIFY FINAL CONTROL JOINT LOCATIONS WHETHER OR NOT
D.M.B. DRY MARKER BOARD L S INDICATED ON THE DRAWINGS WITH ARCHITECT PRIOR TO
DN DOWN L LENGTH SCHED. SCHEDULE STARTING WORK.
BUILDING SECTION CUT REFERENCE
DS DOWNSPOUT LAV. LAVATORY S.D. SOAP DISPENSER NORTH ARROW O. WOOD OR METAL STUD SPACING SHALL BE 16” ON CENTER
DWG. DRAWING LB. POUND SECT. SECTION DRAWING NUMBER UNLESS NOTED OTHERWISE.
1
A101
P. PROVIDE WATER-RESISTANT GYPSUM BOARD ON WALLS
L.H. LEFT HAND S.F. SQUARE FEET SHEET NUMBER INDICATES NORTH DIRECTION
WITH OPERABLE PLUMBING FIXTURES AND WITHIN 4'-0” OF
E L.L.H. LONG LEG HORIZONTAL SHT. SHEET DRINKING FOUNTAINS OR WATER COOLERS.
EA. EACH L.L.O. LONG LEG OUT SIM. SIMILAR Q. PROVIDE FINISHED END PANELS, FILLERS, SUPPORTS, ETC.
E.C. ELECTRICAL CONTRACTOR L.L.V. LONG LEG VERTICAL SPEC. SPECIFICATION WALL SECTION CUT REFERENCE REQUIRED FOR A COMPLETE CABINETRY INSTALLATION.
E.I.F.S. EXTERIOR INSULATION FINISH SYSTEM
1 REVISION REFERENCE PROVIDE CUTOUTS, ACCESS PANELS AND REMOVABLE
SQ. SQUARE DRAWING NUMBER
E.J. EXPANSION JOINT
1 COMPONENTS AS REQUIRED BY NEW OR EXISTING
S.S. STAINLESS STEEL A101 SHEET NUMBER CONDITIONS SUCH AS ELECTRICAL OUTLETS, JUNCTION
EL ELEVATION STD. STANDARD BOXES, CLEANOUTS, ETC. MOUNT TOP OF WALL CABINETS
ELEC. ELECTRIC/ELECTRICAL STL. STEEL AT +7'-0” A.F.F. UNLESS OTHERWISE INDICATED.
ELEV. ELEVATOR/ELEVATION STOR. STORAGE ELEVATION REFERENCE R. VERIFY MOUNTING HEIGHTS OF ACCESSORIES, EQUIPMENT,
ENGR. ENGINEER STRUCT. STRUCTURAL 1/4" / FOOT ROOF SLOPE - ARROW DOOR HARDWARE, CASEWORK, ETC., AND PROVIDE SOLID
E.P. ELECTRICAL PANEL 1 DRAWING NUMBER POINTS TOWARD DRAIN BLOCKING BEHIND ITEMS REQUIRING ANCHORAGE. PROVIDE
SUSP. SUSPEND(ED)
EQ. EQUAL FIRE TREATED WOOD BLOCKING OR METAL STRAPS
SYM. SYMMETRICAL SHEET NUMBER BETWEEN FRAMING MEMBERS AS REQUIRED TO SUPPORT
A101
EQUIP. EQUIPMENT WEIGHT AND USE OF ITEMS TO BE SUPPORTED. WHERE
Room Name ROOM NAME AND NUMBER
E.W.C. ELECTRIC WATER COOLER 101 MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT ITEMS IN
EXIST. EXISTING ACCORDANCE WITH RECOGNIZED INDUSTRY STANDARDS,
EXP. EXPOSED COORDINATE LOCATIONS WITH MANUFACTURER OR
EXT. EXTERIOR SUPPLIER AND REFER MOUNTING HEIGHT QUESTIONS TO
ARCHITECT FOR INTERPRETATION. THIS WOULD ALSO
INCLUDE ALTERNATE BID NO. A-8 TO PROVIDE BLOCKING IN
THE NEW LL1 AND L1 UNIT "F" PRIVATE OFFICE WALLS
STANDARD-PLUMBING FIXTURE REQUIREMENTS WHERE UPPER STORAGE UNITS ARE SHOWN IN A-170 SERIES
DRAWINGS.
S. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME
PERIMETERS AND SURROUNDING WALL CONSTRUCTION
UNLESS OTHERWISE INDICATED.
T. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR
59" MIN. @ FLOOR-MOUNTED TOILET 60" MIN. 24" WINDOW AND STOREFRONT FRAME PERIMETERS AND
SURROUNDING CONSTRUCTION UNLESS OTHERWISE
56" MIN. @ WALL-HUNG TOILET INDICATED.
TOILET PARTITION HAND HELD U. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH
WHERE OCCURS ADJUSTABLE SHOWER AS GYPSUM BOARD AND MASONRY, MASONRY AND
URINAL SCREEN HEAD (ADA)
40" WHERE OCCURS CONCRETE, COUNTERTOPS AND WALLS, ETC.
18" GRAB BAR*
1 1/2" DIAMETER GRAB
CONTROL AREA V. CORRIDOR WALLS SHALL BE ONE-HOUR FIRE-RATED
BAR, 1 1/2" MIN. GAP CONSTRUCTION UNLESS NOTED OTHERWISE.
42" GRAB BAR* ACCESSIBLE SINK
FROM WALL (TYPICAL) W. STAIRWELLS, ELEVATOR HOISTWAYS, ELEVATOR EQUIPMENT
15" MIN. BOWL - 6 1/2" DEEP ROOMS, AND SHAFT WALLS SHALL BE TWO-HOUR FIRE-RATED
34" GRAB BAR* CONSTRUCTION UNLESS OTHERWISE INDICATED.

18"
42" 12" 12" MIN. 24" MIN.
X. REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP SEAL | DATE 04/01/21
TOILET PAPER MIN. ACCESSIBLE MATERIALS WHERE DAMAGED DUE TO INSTALLATION OF NEW
MOUNTING AREA KNEE CLEARANCE MATERIALS TO RESTORE SPECIFIED FIRE RATING.
FOLD DOWN SOAP SHELF, WHERE
70"

Y. THESE NOTES ARE APPLICABLE TO THIS BID PACKAGE ONLY


60" MIN.

SHOWER INDICATED AND MAY NOT BE APPLICABLE TO FUTURE BID PACKAGES.


1 1/2" MIN.

SEAT 18" SOME WORK WHICH WAS INCLUDED IN PREVIOUS BID

38" MAX.
TOE CLEARANCE

48".
PACKAGES OR WILL BE INCLUDED IN FUTURE BID PACKAGES

27" MIN. CLEAR

46"
6" 6" 8"

36" MAX.
SPACE
34" MAX.

33"- 36"
IS SHOWN ON THESE CONSTRUCTION DOCUMENTS FOR
40"

40"
1 1/2" DIAMETER GRAB
34"

11" REFERENCE PURPOSES ONLY AND IS IDENTIFIED AS SUCH.


17" MAX. H.C.

BAR, 1 1/2" MIN. GAP


27"

Z. DO NOT BEGIN WORK THAT MAY REQUIRE COORDINATION,


15" STD.

24" STD.
17" H.C.

FROM WALL (TYPICAL)


SUCH AS CEILING INSTALLATION, PRIOR TO FINAL SUBMITTAL

18"
17"
OF MECHANICAL AND ELECTRICAL COORDINATION DRAWINGS
18" MIN.
9"

9"

9"

TO ARCHITECT NOR PRIOR TO RESOLUTION AND APPROVAL


12" MAX.

OF COORDINATION ISSUES.
7" - 9" AA. REFER TO LIFE SAFETY PLAN DRAWINGS AND CODE
TOE CLEARANCE * 1 1/2" MIN. CLEAR REQUIRED
SUMMARY FOR FIRE-RATED FLOOR, WALL, CEILING AND ROOF
SPACE AROUND ALL GRAB BARS
LOCATIONS. INSTALL FIRESTOPPING AT PENETRATIONS IN SHEET ISSUE
RATED CONSTRUCTION AND AT TOPS OF RATED WALLS.
WATER CLOSET WATER CLOSET URINAL LAVATORY OR VANITY SINK ELECTRIC WATER TRANSFER ADA 1 Construction Documents 04/01/21
BB. REFER TO STRUCTURAL DRAWINGS FOR FOOTING AND
SIDE WALL BACK WALL COOLER SHOWER FOUNDATION DRAINS, UNDERSLAB DRAINAGE AND BACKFILL
ACCESSIBLE FIXTURES INDICATED WITH ACCESSIBLE FIXTURES INDICATED WITH REQUIREMENTS.
HATCH ON FLOOR PLAN HATCH ON FLOOR PLAN CC. REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR SITE
ELEMENTS AND IMPROVEMENTS ADJACENT TO BUILDING
EXTERIOR.
DD. REFER TO A-002 FOR PARTITION CONSTRUCTION TYPE.
EE. WALLS SHOWN WITHIN THE CONFINES OF CONSTRUCTION
THROUGH OMISSION OF GRAY SHADING AT PORTIONS OF
STANDARD TOILET ROOM ACCESSORY MOUNTING HEIGHTS PLAN REQUIRE ARCHITECTURAL WORK. SOME IS REPAIR OF
SELECTIVE WALL DEMO DUE TO REQUIRED SHAFT WORK.
ONCE WORK IS COMPLETED AND STUDS. INSULATION AND
DRYWALL ARE REPAIRED, PROVIDE NEW FINISHES TO MATCH

PER MANUFACTURER'S
EXISTING ADJACENT BASE AND PAINT COLOR. VERIFY

REFLECTIVE SURFACE
DIMENSION FROM

ARCHITECTURAL DESIGN INTENT.

CL OF PUSH BUTTON

RECOMMENDATION
TOP OF CHANGING
COORDINATE WITH

BOTTOM EDGE OF
TOP OF COUNTER
TOP OF CONTROL
FINISH FLOOR

BOTTOM OF UNIT

BOTTOM OF UNIT
TOP OF HANDLE

TOP OF SHELF
TOP OF SHELF

TOP OF HOOK

WHEN IN USE
B.O. MIRROR

TOP OF UNIT

TOP OF UNIT

TOP OF UNIT

CL OF HOOK
CL OF SLOT

CL OF UNIT
CL OF BAR

SURFACE
SURFACE
TO:

OR
MOUNTING

@ COUNTER & LAVS


HEIGHT:

70"
MAX. 48"

MAX. 48"

MAX. 48"

60" TYP.
48" ADA
MAX. 40"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE

54"
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,

33 1/2"
42"

42"
15" MIN.

15" MIN.

40"

40"
MAX
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
34"

34"

34"

34"
30"

25"

COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
24"

PROJECT NO. 19010.000


PAPER TOWEL PAPER TOWEL RECESSED WARM AIR SANITARY NAPKIN/ SANITARY TOILET PAPER TOILET PAPER TOILET TISSUE/ TOILET TISSUE/ GRAB BAR SOAP DISPENSER JANITOR'S MIRROR COAT HOOK/ CLOTHE CHANGING FOLDING WARM-AIR SHEET TITLE
DISPENSER/ DISPENSER PAPER TOWEL HAND DRYER TAMPON VENDOR NAPKIN DISPENSER HOLDER SEAT COVER SANITARY NAPKIN CLOSET SELF DOOR BUMPER S HOOK STATION UTILITY SHELF HAND DRYER
GENERAL NOTES,
ITEM:

WASTE DISPENSER DISPOSAL DISPENSER DISPOSAL/ SEAT


RECEPTACLE COVER
DISPENSER
SYMBOLS, AND
STANDARD
4/1/2021 12:11:25 PM

MOUNTING HEIGHTS
SHEET NUMBER

A-001
INTERIOR PARTITION TYPES INTERIOR PARTITION NOTES

* FIRE RATING AND ACOUSTICAL


ATTENUATION WHEN REQUIRED BY PARTITION
SYMBOL
A. ALL NEW WALLS ARE TYPE S3A.D.A UNLESS NOTED
RHIT MOENCH
REFER TO WALL SECTION FOR CONSTRUCTION
WS OTHERWISE.
B. PARTITION SYMBOLS APPEAR ON LARGEST SCALE FLOOR
PLAN PROVIDED FOR AREA.
RENOVATION
C. REFER TO FINISH AND CEILING PLANS FOR WALL FINISH,
S7FA 7/8" METAL FURRING WITH (1) LAYER 5/8"
GYPSUM WALL BOARD BASE, AND CEILING INFORMATION. SHAFT WALL WORK 5500 Wabash Avenue

1 1/2"
SHOWN IN ARCHITECTURAL PLANS WILL REQUIRE WALL TO
BE REPAINTED CORNER TO CORNER TO MATCH EXISTING
PAINT. Terre Haute, Indiana
D. REFER TO WALL SECTIONS FOR EXTERIOR WALL
S1FA 1 1/2" METAL 'Z' FURRING WITH (1) LAYER
5/8" GYPSUM WALL BOARD ONE SIDE
CONSTRUCTION. 47803

2 1/8"
E. PROVIDE WATER RESISTANT GWB IN ALL ROOMS
CONTAINING OPERABLE PLUMBING FIXTURES AND WITHIN
4 FEET OF DRINKING FOUNTAINS / WATER COOLERS, U.N.O. Owner
F. PROVIDE LATERAL BRACING FOR PARTITIONS WHICH Rose-Hulman Institute of Technology
EXTEND ABOVE CEILING.
3 5/8" METAL STUDS WITH (1) LAYER 5/8" 5500 Wabash Avenue
S3A GYPSUM WALL BOARD EACH SIDE
G. PROVIDE FIRE RESISTIVE RATED GYPSUM WALL BOARD AT
Terre Haute, Indiana 47803

4 7/8"
ALL RATED ASSEMBLIES TO MEET ASSEMBLY
* 1 HR RATED UL419 REQUIREMENTS. 812-877-1511
* ACOUSTIC ATTEN. COMPONENTS STC- H. PROVIDE FIRE RESISTIVE JOINT SYSTEMS EQUAL TO WALL
RATING AT ALL PENETRATIONS AND AT HEAD / FLOOR
INTERSECTIONS WITH RATED ASSEMBLIES.
3 5/8" METAL STUDS WITH (2) LAYERS 5/8"
S3B TYPE X GYPSUM WALL BOARD EACH SIDE
I. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD,
PENETRATIONS AND ADDITIONAL SPECIFIED SOUND

6 1/8"
* 2 HR RATED U419 ATTENUATION COMPONENTS AT SOUND RATED WALLS.
* ACOUSTIC ATTEN. COMPONENTS J. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS
STC-50 SCHEDULED TO HAVE CERAMIC TILE.
K. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM
3 5/8" METAL STUDS WITH (1) LAYER 5/8"
S3C GYPSUM WALL BOARD ONE SIDE
BUILDING STRUCTURE TO PREVENT TRANSFER OF

4 1/4"
VERTICAL LOADS WHILE PROVIDING LATERAL SUPPORT AS
* ACOUSTIC ATTEN. COMPONENTS SPECIFIED. Architect
STC-32 L. STUD SPACING 16" O.C. UNLESS NOTED OTHERWISE
RATIO
REV. 04/03/09 101 South Pennsylvania Street
Indianapolis, Indiana 46204
4" METAL SHAFT WALL STUDS WITH (2)
S4Y LAYERS 5/8" GYPSUM WALL BOARD ONE
317-633-4040

5 1/4"
SIDE AND 1" GYPSUM SHAFT LINER
* 2 HR RATED U417 INTERIOR PARTITION LEGEND
* ACOUSTIC ATTEN. COMPONENTS Structural Engineer
STC-39 PARTITION TYPE SYMBOL
Fink Roberts & Petrie, Inc.
PARTITION DESIGNATION
6" METAL STUDS WITH (1) LAYER 5/8" 9449 Priority Way W Dr #200
S6A GYPSUM WALL BOARD EACH SIDE
PARTITION TYPE Indianapolis, Indiana 46240
317-872-8400

7 1/4"
* ACOUSTIC ATTEN. COMPONENTS FIRE RATING (I.E. 1= 1 HOUR)
STC-44 ACOUSTICAL ATTENUATION
REQ'D
M8A.D.2.A
Mechanical / Electrical Engineer
8" METAL STUDS WITH (1) LAYER 5/8" PARTITION HEIGHT CODE
S8A GYPSUM WALL BOARD EACH SIDE S2A.P R.E. Dimond & Associates, Inc.
732 N Capitol Avenue

9 1/4"
ADDITIONAL PARTITION
DESIGNATION, WHERE
Indianapolis, Indiana 46204
OCCURS 317-634-4672

NEW PARTITIONS

DOUBLE 3 5/8" METAL STUDS WITH (1)


S33A LAYER 5/8" GYPSUM WALL BOARD EACH
SIDE
3 1/2" SPACE BETWEEN STUDS EXISTING PARTITIONS TO REMAIN

1'-0"
PARTITIONS TO BE DEMOLISHED

5 5/8" CONCRETE MASONRY UNIT,


M6A RUNNING BOND INTERIOR PARTITION HEIGHT CODES

5 5/8"
* 2 HR RATED UL906
* ACOUSTIC ATTEN. COMPONENTS
STC-46 (D) TERMINATE AT FLOOR / ROOF DECK

7 5/8" CONCRETE MASONRY UNIT,


M8A RUNNING BOND
(P) TERMINATE 6" ABOVE CEILING

7 5/8"
(C) TERMINATE AT CEILING

6"
HEIGHT AS
7 5/8" CONCRETE MASONRY UNIT WITH INDICATED IN
M8E (1) LAYER 5/8" GYPSUM WALL BOARD INCHES OR (V)
INDICATES

9 3/4"
OVER 1 1/2" METAL FURRING ONE SIDE
HEIGHT THAT
VARIES

8" CAST IN PLACE CONCRETE


C8A * 2 HR RATED (refer to 'equivalent
thickiness' tables in IBC-721.2.1.1)

8"
* ACOUSTIC ATTEN. COMPONENTS STC
>54 (rating based on concrete density-verify
concrete density)

6" METAL STUDS WITH (1) LAYER 5/8"


F6A GYPSUM WALL BOARD EACH SIDE

7 1/4"
SEAL | DATE 04/01/21

SHEET ISSUE
1 Construction Documents 04/01/21

STANDARD-DEVICE MOUNTING GUIDELINES

WALL END OR WALL END OR


OR RECEPTACLES OVER
ELECTRICAL, SWITCHES

EDGE (WHERE EDGE (WHERE


COUNTERS OR SIMILAR
CABINET, HOSE VALVE

COMBINATION OF THE

OCCURS) OCCURS)
FIRE EXTINGUISHER

FIRE EXTINGUISHER
CABINET, FIREHOSE

NOTES:
RECEPTACLE TRIM
WORK SURFACES
CABINET, OR ANY

ELECTRICAL OR

DOOR FRAME OR FIRE ALARM WALL SEGMENT 24" WIDE OR LESS


1. USE THIS DETAIL TO LOCATE
WINDOW FRAME NOTE: ENTIRE LENS TO BE NOT LESS THAN 80" EQ EQ
DEVICES THAT ARE INDICATED ON
AND NOT GREATER THAN 96" AFF
THE DRAWINGS BUT NOT LOCATED
PLATES

BY DIMENSION, OR TO LOCATE
ABOVE

REQUIRED DEVICES THAT ARE NOT


INDICATED ON THE DRAWINGS. 6"

2. ALIGN MULTIPLE DEVICES


COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
HORIZONTALLY AND/OR VERTICALLY THERMOSTAT OR AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
AS DETAILED. TEMPERATURE CONTROL DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
2" COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

3. ITEMS OTHER THAN ELECTRICAL


RECEPTACLES SHALL BE MOUNTED PROJECT NO. 19010.000
NEAR DOORWAYS OR TELEPHONES, DOOR SWITCHES,

6'-8"
SHEET TITLE
INTERSECTING WALLS AS DETAILED DOOR CONTROLLERS, FIRE ALARM
SO AS NOT TO INTERFERE WITH THE PULL SWITCHES AND SIMILAR ITEMS
INTERIOR PARTITION
6"

PLACEMENT OF ART OR FUNITURE - 2" (THE INTENT IS TO ALIGN TOPS OF 2"


EXCEPT THAT WHERE THE WALL ALL OPERABLE ITEMS WHILE
TYPES AND
4'-0"

4'-0"
SEGMENT IS LESS THAN 24" WIDE, ALLOWING THE OPERABLE PARTS WINDOW, DOOR
CENTER THE DEVICES AS DETAILED. TO BE LESS THAN 4'-0" AFF) OR "FEATURE"
THAT SEPARATES
WALL INTO STANDARD
4/1/2021 12:10:17 PM

ELECTRICAL RECEPTACLES - SINGLE, SEGMENTS


1'-3"

GANGED, OR SEPARATED BY 2" PARTITION DETAILS


SHEET NUMBER

A-002
RHIT MOENCH
RENOVATION
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 5500 Wabash Avenue
Terre Haute, Indiana
A A 47803
Owner
Rose-Hulman Institute of Technology
SERVER 5500 Wabash Avenue
OFFICE RECEIVING ROOM
G138 G134
Terre Haute, Indiana 47803
G110 MECHANICAL B B 812-877-1511
TECH SHOP ROOM CHEMICAL
G130 G106 STORAGE STORAGE
FL206 FL205 ELECTRICAL
SWITCH GEAR MECHANICAL
OFFICE OFFICE FL203 FL201
STORAGE OFFICE
G136 G132 WORK AREA
G100B G100A G108
C C
CIRCULATION CIRCULATION RESTROOM MECHANICAL
G100 G111 G101
OFFICE FL202
OFFICE OFFICE
G153 G151 G133 OFFICE Architect
G131 OFFICE OFFICE BREAK AREA RATIO
G123 G113 G103A MAIL DIST.
OFFICE OFFICE OFFICE D CENTER D 101 South Pennsylvania Street
G149 G147 G137 ANNEX Indianapolis, Indiana 46204
OFFICE OFFICE OFFICE EL204 317-633-4040
G135 G121 G115 CONFERENCE N10 N9 N8 N7 N6 N5 N4 N3 N2 N1
OFFICE ROOM DELIVERY DELIVERY
OFFICE G103 STORAGE ELEV 1
OFFICE G143 CAGE CAGE Structural Engineer
G141 OFFICE OFFICE OFFICE G105 -
G145 - -
G139 G119 G117 E E Fink Roberts & Petrie, Inc.
OFFICE ELEVATOR 9449 Priority Way W Dr #200
EL202A MECHANICAL FAB. LAB Indianapolis, Indiana 46240
EL203 STOCK 317-872-8400
STORAGE
CL208
MACHINE FABRICATION Mechanical / Electrical Engineer
F F
TOOL LAB II LAB
EL202 EL207
R.E. Dimond & Associates, Inc.
STAIR CIRCULATION TOOL ROOM 732 N Capitol Avenue
- EL211 EL205 Indianapolis, Indiana 46204
317-634-4672

G G
INSTRUCTIONAL
TECHNOLOGY
DL204

MACHINE
H TOOL SHOP H
I.T. DL202
MENS R.R. EQUIP./OFFICE
DL203 DL204A

J MANAGER J
OFFICE OFFICE
DL204B DL205

WORK SHOP OFFICE


DL206A DL206 MANUFACTURING
K LAB K
DL201

ROBOTICS
CLASSROOM
L DL207 L

MATERIALS
ROBOTICS
M LAB M
WORKROOM/STORAGE
CL207
DL207A
STAIR
CL211

STORAGE
N CL202B N
CUSTODIAL
CUSTODIAL STORAGE
SERVICES CL212
CL202

O O SEAL | DATE 04/01/21

CUSTODIAL OFFICE INSTRUMENT


STORAGE CL203 STORAGE WORK SHOP
CL202A CL205 CL206

P P

5.9 5.5 5.1 4.1 3.1 2.1 1.2

SHEET ISSUE
1 Construction Documents 04/01/21

B5 LOWER LEVEL 2 EXISTING PLAN


AE-101
1/16" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

LOWER LEVEL 2
EXISTING PLAN
4/1/2021 11:29:49 AM

SHEET NUMBER

AE-101
RHIT MOENCH
RENOVATION
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 5500 Wabash Avenue
Terre Haute, Indiana
A A 47803
Owner
CLOSET ANALYTICAL CHEMISTRY Rose-Hulman Institute of Technology
G220A OFFICE OFFICE
LAB LAB
G218 G212 MENS R.R. 5500 Wabash Avenue
FL106 FL104 Terre Haute, Indiana 47803
G206
B B 812-877-1511
OFFICE
CLASSROOM G216 OFFICE STUDY AREA
G222 CLASSROOM G210B G204
G220 BIOCHEMISTRY LAB SUPPORT
WOMENS R.R. OFFICE LAB OFFICE
OFFICE OFFICE CLOSET FL101A
G202 FL107 FL110 FL103
G214 G210A -
C C
OFFICE OFFICE OFFICE OFFICE
FL108 FL109 FL102 FL101

STORAGE Architect
9.8 8.9 7.9 FL102A
6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
OFFICE OFFICE OFFICE OFFICE RATIO
G215B G215A G211 G205 D D 101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
CLASSROOM CLASSROOM N10 N9 N8 N7 N6 N5 N4 N3 N2 N1
G221 G219
OFFICE ELEV 1
OFFICE OFFICE OFFICE OFFICE - Structural Engineer
G205A MAIL
G217 G213 G209 G207 E LOUNGE DISTRIBUTION E Fink Roberts & Petrie, Inc.
EL112 CENTER HOUSEKEEPING 9449 Priority Way W Dr #200
EL106 EQUIPMENT
VENDING
Indianapolis, Indiana 46240
ROOM
MACHINE EL102
317-872-8400
COOK
GREENHOUSE ROOM
G219A EL103
F F Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
WOMENS R.R. MENS R.R.
Indianapolis, Indiana 46204
EL105 EL104
317-634-4672

G G
SEMICONDUCTOR
OFFICE OFFICE OPTICS LAB
OFFICE OFFICE
OFFICE DL110D DL110F DL110G DL108
DL110E OFFICE
DL110C DL107

H H
OFFICE
DL110B OFFICE NUCLEAR OFFICE
DL110A PHYSICS LAB
ADMIN OFFICE DL106
DL105
OPTICAL DL110
J ENGINEERING J
LAB 3
OFFICE OPTICAL
DL115 OFFICE METROLOGY
DL116
DL120 LAB OFFICE
DL104 DL103
ELECTRICAL
EQUIPMENT
K ROOM K
OPTICAL DL118
ENGINEERING
LAB 1 SENIOR OFFICE
DL117 DARK ROOM DESIGN LAB DL102
DL117A DL101
CLASSROOM
L L
DL119 ACOUSTICS
OPTICAL HOLOGRAPHIC PROJECTS
ENGINEERING INTERFEROMETRY LAB OFFICE
LAB 2 LAB CL110 CL109
CL118 CL112
CIRCULATION
CL111
M M
M.T.F.
MEASUREMENT NON-LINEAR CONFERENCE
LAB OPTICS LAB ROOM H BAR
CL114 CL115 CL116 EL108

N N

OFFICE ADMIN OFFICE OFFICE


OFFICE CL108 CL106 CL105
CL107
PHYSICS LAB
O 3 E.I.T. O SEAL | DATE 04/01/21
CIRCULATION
CL117 CL102A BL119
CLASSROOM
CL119 OFFICE
ELECTRICAL OPTICAL
ROOM STORAGE COMMUNICATIONS CL104
CL101 CL102B LAB
CL103
P P
ENGINEERING OFFICE
PHYSICS LAB BL103 OFFICE
MATERIALS 1 BL102
PROCESSING BL110
PHYSICS LAB LAB
BL112 OFFICE
Q 1 Q
BL113 BL104 SHEET ISSUE
PHYSICS 1 Construction Documents 04/01/21
STOCK ROOM OFFICE OFFICE
BL108 BL109 OFFICE BL101
BL105

R R

MACHINE
ELECTRICAL SHOP OFFICE OFFICE
ROOM BL107 BL106 BL100
PHYSICS LAB BL115
2 CUSTODIAL
S STORAGE S
BL114
BL116 ELEV 2
BL118
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
OFFICE OFFICE OFFICE
AL104 AL103 AL102
T T
ELEVATOR
MECHANICAL STORAGE
BL117 AL101A
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
ART CURATOR WATER ROOM
AL101 AL106
U U

V V
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE
W W
LOWER LEVEL 1
EXISTING PLAN
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
4/1/2021 11:29:55 AM

A5 LOWER LEVEL 1 EXISTING PLAN


AE-102
1/16" = 1'-0" SHEET NUMBER

AE-102
RHIT MOENCH
RENOVATION
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 5500 Wabash Avenue
Terre Haute, Indiana
A A 47803
Owner
NMR LAB RESEARCH
LAB CHEMICAL Rose-Hulman Institute of Technology
F106 STORAGE
F105 5500 Wabash Avenue
F102A
Terre Haute, Indiana 47803
B B 812-877-1511
LAB LAB ORGANIC LAB GENERAL
CLASSROOM CLASSROOM STOCKROOM
G306 G304 F108 COMPUTER CHEMISTRY
G310 G308 F102
AND Room LAB
STOCKROOM
REFERENCE F101A F101
OFFICE MANAGER
CLOSET ROOM
F104 F103
G304A F107
C C
CUSTODIAL
STORAGE
F113
PREPARATION
OFFICE OFFICE ADMIN OFFICE COPYROOM LAB
Architect
9.8 8.9 F109 7.9 F110 6.9 F111 F112
5.9 5.5 5.1 F114 4.1 3.1 2.1 1.2
RATIO
OFFICE
D D 101 South Pennsylvania Street
G309
EQUIPMENT SERVER/EQUIP. Indianapolis, Indiana 46204
CLASSROOM CLASSROOM CLASSROOM REPAIR ROOM STORAGE 317-633-4040
OFFICE
N10 N9 N8 N7
E107A
N6 E107C
N5 N4 N3 CLASSROOMN2 N1
G317 G315 G313
G305 ELEV 1 E104
OFFICE - Structural Engineer
G311 OFFICE WOMENS R.R.
E E109 E Fink Roberts & Petrie, Inc.
G307 TECHNICIAN
OFFICE 9449 Priority Way W Dr #200
WORKSHOP E107B MENS R.R. Indianapolis, Indiana 46240
E107 E108 317-872-8400

F F Mechanical / Electrical Engineer


Room
E102
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
Room 317-634-4672
E101
G G
OFFICE
OFFICE OFFICE
D113
ENERGY D108 D107
CONVERSION REFERENCE
AND POWER CLASSROOM (CONFERENCE)
SYSTEMS D112 ROOM
LABORATORY OFFICE D110 OFFICE
H D114
OFFICE OFFICE D106 H
D111-1 D111 D109

OFFICE
D105

J J
ELECTRONIC OFFICE
CALIBRATION D104
LABORATORY
D116
CIRCUITS
ECE LAB TECH
LEARNING
LABORATORY D117
CENTER DESIGN LAB OFFICE
K D115 D101-A D101 D103 K
OFFICE
D118

STORAGE OFFICE
D116 D102

L L
INSTRUMENT
ROOM OFFICE
EQUIPMENT C114 C110
WORKSHOP/STORAGE
STORAGE
C112
C115A

DIGITAL
ELECTRONIC
MECHATRONICS OFFICE
M C111 C109 M
MICROCOMPUTER
LABORATORY
C115
OFFICE
C108

N N

DYNAMIC MAIL ROOM


SYSTEMS AND OFFICE OFFICE C104
CONTROLS C117 C118
LABORATORY
O O SEAL | DATE 04/01/21
C116
OFFICE ADMIN
SERVER WORKROOM / C103
ROOM BREAKROOM
OFFICE OFFICE
B107B C103A
C101A C105

P P
ELECTRICAL
STAIR
ROOM
-
B107A STORAGE
ELECTRICAL B105A
ROOM
CLASSROOM
B107
B106 ADVANCED
Q CIRCUIT Q
STUDY AREA SHEET ISSUE
- OFFICE LABORATORY
B108B B105 1 Construction Documents 04/01/21
OFFICE
B108C
OFFICE E.I.T.
B108A B103C
R R
TEST OFFICE
BUSINESS SOLDERING OFFICE
AND FINANCE ENGINEERING B103A
LAB LAB B101 OFFICE
CONFERENCE
B104 B102 B100
ROOM
OFFICE
B109
B103B
S CUSTODIAL
S
ELEV 2 CIRCULATION
STORAGE
GM ROOM - B103
B110
S10 S9 B111 S8 S7 S6 S5 S4 S3 S2 S1

T T
CIRCULATION WORKROOM / OFFICE
SERVER
OFFICE A100 BREAKROOM A105
ROOM OFFICE
9.8 A140 8.9 7.9 6.9 5.9 A100A
5.5 5.1 4.1 A102B
3.1 OFFICE 2.1 1.2
A102A
OFFICE OFFICE A103
OFFICE OFFICE OFFICE
A136 A138 ADMIN OFFICE
A124 A126 A106
A102
U WORKROOM / STORAGE U
BREAKROOM OFFICE A104B OFFICE
APPLICATIONS A122 A101 A107
ELECTRICAL
READING A118A
STORAGE
ROOM OFFICE STORAGE OFFICE ELEC. AND SAFE OFFICE OFFICE
A130 A128 A120B A118 STORAGE A104A A104
A120A A108
A101A
V CIRCULATION V
ADMIN OFFICE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
A120 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
A113 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
OFFICE COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
OFFICE A109
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
A121 PROJECT NO. 19010.000
A123 A125 A127 A129 A117 A116 A115 A114 A112 A111 A110
SHEET TITLE
W W
FIRST LEVEL
EXISTING PLAN
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
4/1/2021 11:30:02 AM

A5 FIRST LEVEL EXISTING PLAN


AE-103
1/16" = 1'-0" SHEET NUMBER

AE-103
RHIT MOENCH
RENOVATION
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 5500 Wabash Avenue
Terre Haute, Indiana
A
CONFERENCE
A 47803
ROOM OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE Owner
F230 F228 F226 F224 F222 F220 F218 F216 F214 F212 F210
Rose-Hulman Institute of Technology
5500 Wabash Avenue
STORAGE Terre Haute, Indiana 47803
B ADMIN OFFICE F208 B 812-877-1511
F231 BREAK AREA
USABILITY F207
LAB OFFICE
WORKROOM / F225A F206
BREAKROOM OFFICE
F233 CSSE LAB F205
CSSE LAB
C USABILITY F225 C
LAB CONTROL F217 OFFICE
ROOM F204
STAIRWELL F225B
F235 CUSTODIAL OFFICE
F237 F203 Architect
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
RATIO
D D 101 South Pennsylvania Street
Indianapolis, Indiana 46204
MECHANICAL 317-633-4040
N10 N9 N8 N7
ROOM N6 N5 N4 N3 CLASSROOMN2 N1
E203 E104
ELEV 1 WOMENS R.R.
E203 E202 Structural Engineer
E E Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
OFFICE OFFICE MECHANICAL Indianapolis, Indiana 46240
OFFICE E206 E205 ROOM 317-872-8400
E207 E201

F F Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
MOENCH 732 N Capitol Avenue
CAFE
Indianapolis, Indiana 46204
E200
317-634-4672

G G
STORAGE OFFICE
OFFICE
D223A D208
D222
OFFICE OFFICE OFFICE OFFICE
OFFICE D220 D221 D209 OFFICE
D224
D223 D207
H H
STORAGE OFFICE
OFFICE D226A OFFICE
D219A
D225 STUDENT D206
OFFICE
STUDY AREA
OFFICE D219
D210
OFFICE D227 OFFICE OFFICE
D226 D219B D205
J STORAGE
J
STORAGE /
D217A OFFICE OFFICE
WORKROOM
D218 D204
OFFICE D226C OFFICE
D228 ADMIN OFFICE OFFICE D211
D229 D216 OFFICE OFFICE
D217 D203
K STORAGE
K
OFFICE OFFICE
D226D
D230 D202
CONFERENCE
OFFICE
OFFICE OFFICE D215B ROOM
OFFICE D212 OFFICE
OFFICE D232 D214 D215A
D201
D231
L L
MECHANICAL OFFICE
ROOM MECHANICAL C211
ROOM OFFICE
C215
C214 C212
OFFICE
C210
M IT CLOSET M
C200B OFFICE
STAFF C209
STUDY AREA RESOURCES
- C200
OFFICE
STORAGE C208
C200A
N N
CIRCULATION
B210
OFFICE
C216 OFFICE
C217

O O SEAL | DATE 04/01/21


MECHANICAL MECHANICAL ADMIN
ROOM ROOM C205 OFFICE
C218 C201 C206

P P
STORAGE
MECHANICAL
W9NAA ROSE C205B
ROOM
TECH RADIO
MECHANICAL B202
CLUB
ROOM B204
B203
Q PROJECTION
Q
STUDENT
SHEET ISSUE
ROOM
CONFERENCE BBE HIVE OFFICE 1 Construction Documents 04/01/21
B111A
ROOM B201
B205
B205A

R R
SYNTHETIC
DIGITAL
BIOLOGY
SIGNAL
LABORATORY
PROCESSING
B206
LAB
B200
S S
ELEV 2
GM ROOM B208
S10 S9 B111 S8 MECHANICAL
S7 S6 S5 S4 S3 S2 S1
ROOM
B207

T T
CUSTODIAL
STORAGE MECHANICAL
OFFICE A223A ROOM
9.8 ADMIN OFFICE8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
A218A CLASSROOM MENS R.R. A301
A218 CLASSROOM
A219 WOMENS R.R. A223 CLASSROOM
A220 A222 A202
STORAGE /
U STORAGE / STORAGE / PROJECTOR U
PROJECTOR PROJECTOR ELECTRICAL A202A
OFFICE OFFICE A219A A220A SITTING AREA ROOM OFFICE
A218C A218B - BREAKROOM A200A A201
A200 WORK AREA / OFFICE
STORAGE A203A
STORAGE CIRCULATION A203
A219B A220F
V V
OFFICE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
A203B DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
WORKROOM COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
OFFICE OFFICE
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE A207 OFFICE OFFICE
A209 OFFICE A203D
A217 A216 A215 A214 A213 A212 A211 A210 ADMIN OFFICE A206 A205 A204 OFFICE PROJECT NO. 19010.000
A208 A203C
SHEET TITLE
W W
SECOND LEVEL
EXISTING PLAN
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
4/1/2021 11:30:10 AM

A5 SECOND LEVEL EXISTING PLAN


AE-104
1/16" = 1'-0" SHEET NUMBER

AE-104
GENERAL DEMOLITION NOTES
A. THESE GENERAL DEMOLITION NOTES APPLY TO DEMOLITION DRAWINGS.
B. FIELD VERIFY CONDITIONS AND COORDINATE DEMOLITION OR REMOVAL WORK
RHIT MOENCH
WITH CORRESPONDING NEW CONSTRUCTION AND WITH APPROPRIATE TRADES
PRIOR TO STARTING DEMOLITION WORK. IF DISCREPANCIES ARE FOUND
BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, NOTIFY
RENOVATION
ARCHITECT IMMEDIATELY.
C. OWNER WILL REMOVE LOOSE SALVAGEABLE ITEMS, I.E., EQUIPMENT, FURNITURE,
CABINETRY, FILE CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK,
5500 Wabash Avenue
PLAQUES, ETC., PRIOR TO CONTRACTOR STARTING DEMOLITION WORK IN EACH
AREA. OWNER WILL STORE AND REINSTALL SUCH ITEMS. [OR] OWNER WILL STORE
MAJORITY OF LOOSE SALVAGEABLE ITEMS IN THE CENTER OF EACH ROOM
Terre Haute, Indiana
CONTAINING SAID ITEMS, I.E., EQUIPMENT, FURNITURE, CABINETRY, FILE
CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK, ETC., PRIOR TO
47803
CONTRACTOR STARTING WORK. CONTRACTOR SHALL PROTECT SUCH ITEMS
DURING CONSTRUCTION. Owner
D. DEMOLISHED MATERIALS ARE THE PROPERTY OF THE CONTRACTOR UNLESS
NOTED OTHERWISE AND SHALL BE PROMPTLY DISPOSED OF OFF-SITE.
Rose-Hulman Institute of Technology
E. ITEMS NOTED TO BE REMOVED AND TURNED OVER TO OWNER SHALL BE 5500 Wabash Avenue
DELIVERED AS DIRECTED BY OWNER. Terre Haute, Indiana 47803
F. REMOVE ITEMS IN THEIR ENTIRETY UNLESS OTHERWISE INDICATED. 812-877-1511
DESCRIPTION OF PRIMARY ITEMS TO BE REMOVED IS GENERAL IN NATURE, AND
REMOVAL OF SECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS,
ANCHORS, TRIM, ADHESIVE, PIPING, WIRING, ETC., RELATED TO PRIMARY ITEMS
SHALL BE INCLUDED.
G. PROTECT EXISTING SURFACES TO REMAIN IN AREAS ADJACENT TO DEMOLITION
WORK.
H. REPAIR FINISHES AND SURFACES LEFT EXPOSED BY DEMOLITION OR REMOVAL OF
EQUIPMENT, USING NEW MATERIALS TO MATCH SURROUNDING SURFACES.
REPAIR EXISTING FLOOR, BASE, WAINSCOT, WALL AND CEILING FINISHES TO
CORRECT DEFECTS EITHER CAUSED OR EXPOSED BY DEMOLITION WORK OR
EQUIPMENT REMOVAL. REPAIRED SURFACES SHALL BE SMOOTH AND
UNDETECTABLE UNDER FINAL FINISHES. AREAS NOTED ON THE DRAWINGS TO BE Architect
REPAIRED OR PATCHED ARE GIVEN FOR REFERENCE AND SHALL NOT BE
AD-201 INTERPRETED TO LIMIT THE SCOPE OF WORK. RATIO
I. PATCH EXISTING FLOOR, WALL, CEILING AND ROOF CONSTRUCTION AT 101 South Pennsylvania Street
ABANDONED PENETRATION LOCATIONS WITH NEW MATERIALS AS REQUIRED TO Indianapolis, Indiana 46204
A3 RECEIVE NEW FINISHES AND TO MAINTAIN ORIGINAL FIRE RATING OF ASSEMBLY 317-633-4040
WHERE APPLICABLE.
J. PORTIONS OF EXISTING MASONRY WALLS NOTED TO BE REMOVED AND OPENINGS
TO BE CUT INTO EXISTING MASONRY WALLS SHALL BE REMOVED BACK TO THE
NEAREST VERTICAL MORTAR JOINT. PROVIDE A MINIMUM BEARING OF 8 AT EACH Structural Engineer
END FOR NEW MASONRY LINTELS AND FIELD VERIFY FINAL LENGTH. ALLOW A Fink Roberts & Petrie, Inc.
07 MINIMUM OF 4 NEW MASONRY AT JAMB CONDITIONS OR END WALL CONDITIONS
OF MASONRY WALLS. REFER TO DEMOLITION PLANS FOR LOCATIONS OF WALL, 9449 Priority Way W Dr #200
FLOOR, CEILING OR ROOF OPENINGS. Indianapolis, Indiana 46240
07 K. PROVIDE SMOOTH TRANSITIONS BETWEEN FLOOR, WALL AND CEILING SURFACES 317-872-8400
07 C3 AD-201 PRIOR TO INSTALLING NEW FINISHES WHERE WALLS OR OTHER ITEMS ARE
AD-201 C6 REMOVED. FILL FLOOR VOIDS WITH CONCRETE OR MATERIAL MATCHING
07 ADJACENT MATERIALS AND LEVEL FLOOR SURFACES TO PROVIDE A SMOOTH
07 TRANSITION FROM ONE SIDE OF WALL TO THE OTHER WHERE PORTIONS OF Mechanical / Electrical Engineer
WALLS ARE REMOVED. R.E. Dimond & Associates, Inc.
07 L. ADDITIONAL FLOOR TILE MAY BE PRESENT BENEATH FINISHES IN ROOMS WITH
EXISTING FLOOR TILE OR CARPET. REMOVE ALL LAYERS OF EXISTING FLOOR 732 N Capitol Avenue
COVERINGS TO PROVIDE APPROPRIATE SUBSTRATE FOR NEW FLOOR FINISHES. Indianapolis, Indiana 46204
07 07 M. SELECTIVE DEMOLITION FOR INSTALLATION OF NEW MECHANICAL OR ELECTRICAL 317-634-4672
N.I.C. 07 WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR TRADE
REQUIRING THE DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, FLOOR
SLAB AND PAVEMENT CUTTING FOR UNDERGROUND PIPING, CORING FOR WALL
AND FLOOR PENETRATIONS, ROOF PENETRATIONS, ETC. REFER TO MECHANICAL
07 07 07
AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION.
N. DISCONNECT AND CAP-OFF OR REMOVE OBSOLETE EXISTING UTILITY AND
11 SERVICE LINES PRIOR TO STARTING DEMOLITION WORK.
07 08 O. REMOVE ABANDONED UNDERGROUND UTILITIES AND INSTALL ENGINEERED FILL.
P. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE SUSPECTED OR
07 DISCOVERED TO CONTAIN ASBESTOS OR OTHER HAZARDOUS MATERIALS, STOP
07 08 DEMOLITION AND NOTIFY OWNER AND ARCHITECT IMMEDIATELY.
07 08 07 08 Q. REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP MATERIALS WHERE
DAMAGED DUE TO SELECTIVE DEMOLITION ACTIVITIES TO RESTORE ORIGINAL
FIRE RATING UNLESS OTHERWISE INDICATED.
07 R. THE FOLLOWING DEMOLITION WORK SHALL BE PERFORMED AS PART OF THE
07 08 08 07 WORK UNDER THE APPROPRIATE PROJECT MANUAL SECTIONS: A.) REMOVAL OF
EXISTING ROOFING. B.) REMOVAL OF EXISTING WINDOWS, TEMPORARY WINDOW
OPENING CLOSURES AND OPENING PREPARATION TO RECEIVE NEW WINDOW
UNITS.
07 S. REFER TO WALL SECTIONS NOTED ON DEMOLITION PLANS FOR ADDITIONAL
DEMOLITION INFORMATION.
T. REFER TO PROJECT MANUAL DIVISION 4 FOR SPECIAL REQUIREMENTS
07 08 REGARDING DISPOSAL OF DEMOLISHED MASONRY RUBBLE.
07 U. ALL WALL AND FLOOR FINISHES ARE TO REMAIN UNLESS NOTED OTHERWISE.
07
38 08
REV. 11/08/05

KEYNOTES - DEMOLITION
07 08
07
08
01 REMOVE EXISTING WALL CONSTRUCTION, DOORS AND FRAMES COMPLETELY. F
02 REMOVE EXISTING BRICK WIINDOW FILL IN IT'S ENTIRETY.
03 DUCTED FUME HOODS TO BE REMOVED BY THE HAZARDOUS MATERIAL ABATEMENT
3 G

12 07
CONTRACTOR.
04 REMOVE EXISTING BUILT-IN EQUIPMENT/CABINETRY IN IT'S ENTIRETY.
E
2
07 08 07 08
05 REMOVE EXISTING LOOSE EQUIPMENT, MACHINES, FURNITURE AND INSTALLED D
MARKERBOARDS STORE AS REQUESTED BY OWNER.
06 EXISTING WOOD FLOORING AND STRUCTURE ABOVE TO REMAIN
07 REMOVE ALL EXISTING MECHANICAL, TIE UP AND SALVAGE LIGHT FIXTURES ONLY
C
WHERE CEILING GRID REPLACEMENT OCCUR, WHERE CEILING IS TO REMAIN EXPOSED
07 08 07 08 TO DECK, ASSUME NEW MECHANICAL AND OTHER COMPONENTRY IS TO BE DRYFALL
PAINTED TO MATCH EXISTING EXPOSED STRUCTURE. WHERE CEILING IS EXPOSED
B 1
WOOD TIMBER, COLOR OF DUCTS IS TO BE DETERMINED.
07 08 REMOVE EXISTING ACOUSTICAL TILE CEILING AND SUPPORTS IN IT'S ENTIRETY. TIE UP A
07 08 07 08 AND SALVAGE LIGHT FIXTURES AS DESCRIBED IN NOTE 07. ASSUME NEW CEILING
GRID AND TILES ARE TO BE INSTALLED AND WILL CONCEAL NEW MECHANICAL
EQUIPMENT..
KEY PLAN
08 09 REMOVE EXISTING LIGHTING IN THIS SHADED AREA. REFERENCE RCP FOR CEILING IN
07 THIS AREA.
10 REMOVE EXISTING FLOORING, BASE AND WALL FINISHES IN THEIR ENTIRETY AND SEAL | DATE 04/01/21
08 PREPARE FOR NEW.
07 11 DESIGN INTENT IS TO MAINTAIN VERTICAL FACE AND UNDERSIDE OF BULKHEADS/
DRYWALL CEILINGS WHERE POSSIBLE AND PATCH TO AS-NEW CONDITION IF ANY
WORK ABOVE THE CEILING IS REQUIRED, IN LIEU OF REBUILDING IF ANY LIGHT
FIXTURES EXIST, SALVAGE AND REUSED IN PATCHED CEILING IF POSSIBLE..
12 REMOVE EXISTING DRYWALL CEILING AND SUPPORTS. REFERENCE RCP FOR FINAL
DESIGN INTENT. IF IN EXISTENCE, WALL SCONCES ARE TO REMAIN.. IF CEILING
07 LIGHTS EXIST, SALVAGE FOR REUSE IN NEW CEILING UNLESS SHOWN OTHERWISE IN
NEW CEILING PLAN..
13 EXISTING TO REMAIN.
08 07
14 REMOVE HORIZONTAL PORTION OF HARDLID CEILINGS FOR HVAC WORK. REMOVE
WOOD PANELING IN CEILINGS. EXISTING STEPPED COFFER, DRYWALL WRAPPED
08 TRUSSES AND VERTICAL PORTIONS OF HARDLID CEILINGS TO REMAIN FOR REUSE.
38 07 07 15 REMOVE EXISTING CERAMIC TILE ON WALLS AND FLOOR IN ITS ENTIRETY.
SHEET ISSUE
16 REMOVE EXISTING LEVEL 2 BRIDGE CONSTRUCTION AND RAILING IN ITS ENTIRETY TO
CREATE OPENING TO BELOW 1 Construction Documents 04/01/21
07 07 17 CAREFULLY SALVAGE ACOUSTICAL PANELS MOUNTED TO WALLS FOR POSSIBLE
08
REUSE BY OWNER. VERIFY RELOCATION DIRECTION WITH OWNER.
07 18 WALLS N THIS AREA REPRESENT TEMPORARY OFFICES CREATED IN INTIAL PHASE OF
CONSTRUCTION. THESE ARE TO BE REMOVED, ALONG WITH CEILINGS AND FINISHES
29 AT CORRECT PHASE TO CONVERT THESE ROOMS TO CLASSROOMS. EXISTING
CEILINGS CAN REMAIN AND LIGHTING RECONFIGURED DURING TEMPORARY OFFICE
N.I.C.
PHASE AND ALL IS TO BE REMOVED FOR FINAL CLASSROOM PHASE.
19 REMOVE EXISTING GLAZING AND FRAMING AS REQUIRED TO ACCEPT NEW
MECHANICAL LOUVER.
07 07
08 20 REMOVE EXISTING WINDOWS AND FRAMES IN THEIR ENTIRETY.
08 21 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
07
STRUCTURAL.
07 08 22 REMOVE EXISTING SKYLIGHT FRAME, GLAZING, AND ACCESSORIES DOWN TO EXISTING
CURB IN ENTIRETY.
23 REMOVE EXISTING ROOF DUCT CHASE, FRAMING, AND ROOFING IN ENTIRETY.
24 REMOVE EXISTING ROOFING, INSULATION, AND CRICKET MATERIAL IN ENTIRETY TO
RECEIVE NEW ROOF AND FLASHINGS.
25 REMOVE EXISTING METAL LADDER, PLATFORM, AND SUPPORTS COMPLETE.
26 REMOVE EXISTING DOOR PANEL AND HARDWARE AT TOP OF PLATFORM, FRAME TO
REMAIN.
27 REMOVE EXISTING CONCRETE HOUSEKEEPING PAD FLUSH TO SURROUNDING FLOOR
ELEVATION TO RECEIVE NEW HOUSEKEEPING PAD.
29 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF ACADEMIC
BUILDING CONSTRUCTION. EXISTING TO REMAIN WITHOUT DISRUPTION IF POSSIBLE.
IF NOT POSSIBLE, ASSUME NARRATIVE FROM 07 AND 08 TO BE APPLIED TO THIS AREA.
30 ALTERNATE BID # A-2: REPLACE EXISTING LINEAR PENDANT WITH NEW SPECIALTY
LIGHTING FOR LIVING WALL PER ELECTRICAL LIGHTING PLANS
31 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF 2020
SUMMER CONSTRUCTION. AS MUCH OF EXISTING CENTER PORTION TO REMAIN
WITHOUT DISRUPTION IF POSSIBLE.
33 REMOVE EXISTING SKYLIGHT AND LIGHTING. REFERENCE ARCHITECTURAL AND
B5 LOWER LEVEL 2 DEMOLITION PLAN DETAILED SECTIONS FOR ARCHITECTURAL DESIGN INTENT TO DETERMINE EXTENT OF
DEMOLITION.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AD-111 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
1/16" = 1'-0" 34 FLOORING TO REMAIN AT STAIRS. REMOVE EXISTING DISPLAY PILASTERS UNDER
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
STAIRS.
35 REMOVE ALL EXISTING CEILING, LIGHTING, REMAINING WALL FINISHES AND FLOOR PROJECT NO. 19010.000
FINISHES. PREP AREA FOR NEW CEILING, FINISHES, HVAC AND FLOOR PLAN LAYOUT
AS NEEDED. SHEET TITLE
36 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL. REMOVE EXSTING LIGHTING IN THIS AREA. LOWER LEVEL 2
37 INVESTIGATE CONSTRUCTION OF THIS HORIZONTAL BEAM TO DETERMINE FEASIBILITY
OF REMOVING BOTTOM FURRING STRIPS AND RECONSTRUCTION TO MATCH HEIGHT
OF HORIZONTAL BEAM TO
DEMOLITION PLAN
38 PROVIDE ALT. BID NO A-5 TO REMOVE EXISITNG QUARRY TILE ON STAIRS AND
4/1/2021 11:29:00 AM

PREPARE FOR NEW TREADS, RISERS, LANDING AND STRINGERS AS REQUIRED PER
THE FINISH PLANS. THIS INCLUDES REMOVAL OF PEDESTALS ON LEVEL 1.
39 REMOVE ROOFING, INSULATION, AND STRUCTURE AS REQUIRED FOR NEW ROOF
HATCH.
40 SELECTIVELY DEMO AS REQUIRED FOR HVAC WORK. IF FLOORING ABOVE IS SHEET NUMBER
AFFECTED, CAREFULLY SALVAGE FLOORING FOR REINSTALLATION AFTER HVAC WORK

AD-111
IS COMPLETE.
41 SELECTIVELY DEMO BEHIND COLUMNS TO ALLOW FOR FULL PENETRATION WELDING
OF COLUMN STUBS.
GENERAL DEMOLITION NOTES
A. THESE GENERAL DEMOLITION NOTES APPLY TO DEMOLITION DRAWINGS.
B. FIELD VERIFY CONDITIONS AND COORDINATE DEMOLITION OR REMOVAL WORK
RHIT MOENCH
WITH CORRESPONDING NEW CONSTRUCTION AND WITH APPROPRIATE TRADES
PRIOR TO STARTING DEMOLITION WORK. IF DISCREPANCIES ARE FOUND
BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, NOTIFY
RENOVATION
ARCHITECT IMMEDIATELY.

AD-201
C. OWNER WILL REMOVE LOOSE SALVAGEABLE ITEMS, I.E., EQUIPMENT, FURNITURE,
CABINETRY, FILE CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK,
5500 Wabash Avenue
02 02 02
A3
PLAQUES, ETC., PRIOR TO CONTRACTOR STARTING DEMOLITION WORK IN EACH
AREA. OWNER WILL STORE AND REINSTALL SUCH ITEMS. [OR] OWNER WILL STORE
MAJORITY OF LOOSE SALVAGEABLE ITEMS IN THE CENTER OF EACH ROOM
Terre Haute, Indiana
CONTAINING SAID ITEMS, I.E., EQUIPMENT, FURNITURE, CABINETRY, FILE
CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK, ETC., PRIOR TO
47803
CONTRACTOR STARTING WORK. CONTRACTOR SHALL PROTECT SUCH ITEMS
01 DURING CONSTRUCTION. Owner
03
D. DEMOLISHED MATERIALS ARE THE PROPERTY OF THE CONTRACTOR UNLESS
01 35
04 05 03 NOTED OTHERWISE AND SHALL BE PROMPTLY DISPOSED OF OFF-SITE.
Rose-Hulman Institute of Technology
35 05 05 05 35 01 35 04 01 E. ITEMS NOTED TO BE REMOVED AND TURNED OVER TO OWNER SHALL BE 5500 Wabash Avenue
DELIVERED AS DIRECTED BY OWNER. Terre Haute, Indiana 47803
02 01 01 F. REMOVE ITEMS IN THEIR ENTIRETY UNLESS OTHERWISE INDICATED. 812-877-1511
01
05 05 03 N.I.C. C3 AD-201 DESCRIPTION OF PRIMARY ITEMS TO BE REMOVED IS GENERAL IN NATURE, AND
05 REMOVAL OF SECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS,
35 35 AD-201 C6
35 01 ANCHORS, TRIM, ADHESIVE, PIPING, WIRING, ETC., RELATED TO PRIMARY ITEMS
05 SHALL BE INCLUDED.
35 05 04 05 05
35 G. PROTECT EXISTING SURFACES TO REMAIN IN AREAS ADJACENT TO DEMOLITION
01 01 01 35 01 01 35 WORK.
35 05 35 05 H. REPAIR FINISHES AND SURFACES LEFT EXPOSED BY DEMOLITION OR REMOVAL OF
35 05 EQUIPMENT, USING NEW MATERIALS TO MATCH SURROUNDING SURFACES.
01 35 05
35 35 05 35 REPAIR EXISTING FLOOR, BASE, WAINSCOT, WALL AND CEILING FINISHES TO
05 05 01 35 35 CORRECT DEFECTS EITHER CAUSED OR EXPOSED BY DEMOLITION WORK OR
N.I.C. 10
07 EQUIPMENT REMOVAL. REPAIRED SURFACES SHALL BE SMOOTH AND
07 10 UNDETECTABLE UNDER FINAL FINISHES. AREAS NOTED ON THE DRAWINGS TO BE
01 Architect
05 01 35 01 REPAIRED OR PATCHED ARE GIVEN FOR REFERENCE AND SHALL NOT BE
05 INTERPRETED TO LIMIT THE SCOPE OF WORK. RATIO
05 I. PATCH EXISTING FLOOR, WALL, CEILING AND ROOF CONSTRUCTION AT
35 05 01 101 South Pennsylvania Street
35 35 ABANDONED PENETRATION LOCATIONS WITH NEW MATERIALS AS REQUIRED TO
35 17 10 07 Indianapolis, Indiana 46204
05
07 10 11 10 07 07 07 RECEIVE NEW FINISHES AND TO MAINTAIN ORIGINAL FIRE RATING OF ASSEMBLY 317-633-4040
01 35 WHERE APPLICABLE.
09 J. PORTIONS OF EXISTING MASONRY WALLS NOTED TO BE REMOVED AND OPENINGS
05 05 01 TO BE CUT INTO EXISTING MASONRY WALLS SHALL BE REMOVED BACK TO THE
05 01 07 NEAREST VERTICAL MORTAR JOINT. PROVIDE A MINIMUM BEARING OF 8 AT EACH Structural Engineer
05 05 35 35
35 END FOR NEW MASONRY LINTELS AND FIELD VERIFY FINAL LENGTH. ALLOW A Fink Roberts & Petrie, Inc.
35 01 01 01
35 MINIMUM OF 4 NEW MASONRY AT JAMB CONDITIONS OR END WALL CONDITIONS
04 05 09 OF MASONRY WALLS. REFER TO DEMOLITION PLANS FOR LOCATIONS OF WALL, 9449 Priority Way W Dr #200
05 10 07 10 01 07 05 FLOOR, CEILING OR ROOF OPENINGS. Indianapolis, Indiana 46240
17 08 10 K. PROVIDE SMOOTH TRANSITIONS BETWEEN FLOOR, WALL AND CEILING SURFACES 317-872-8400
04 01 PRIOR TO INSTALLING NEW FINISHES WHERE WALLS OR OTHER ITEMS ARE
01 REMOVED. FILL FLOOR VOIDS WITH CONCRETE OR MATERIAL MATCHING
11 ADJACENT MATERIALS AND LEVEL FLOOR SURFACES TO PROVIDE A SMOOTH
01 37 TRANSITION FROM ONE SIDE OF WALL TO THE OTHER WHERE PORTIONS OF Mechanical / Electrical Engineer
07
09 10
10 09 10 12 12 WALLS ARE REMOVED. R.E. Dimond & Associates, Inc.
07 L. ADDITIONAL FLOOR TILE MAY BE PRESENT BENEATH FINISHES IN ROOMS WITH
EXISTING FLOOR TILE OR CARPET. REMOVE ALL LAYERS OF EXISTING FLOOR 732 N Capitol Avenue
34 38 38 34 Indianapolis, Indiana 46204
12 12 COVERINGS TO PROVIDE APPROPRIATE SUBSTRATE FOR NEW FLOOR FINISHES.
M. SELECTIVE DEMOLITION FOR INSTALLATION OF NEW MECHANICAL OR ELECTRICAL 317-634-4672
17 10 WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR TRADE
REQUIRING THE DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, FLOOR
SLAB AND PAVEMENT CUTTING FOR UNDERGROUND PIPING, CORING FOR WALL
AND FLOOR PENETRATIONS, ROOF PENETRATIONS, ETC. REFER TO MECHANICAL
07 07 07 07 07 07 07 AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION.
08 08 08 08 08 08 08 N. DISCONNECT AND CAP-OFF OR REMOVE OBSOLETE EXISTING UTILITY AND
07 SERVICE LINES PRIOR TO STARTING DEMOLITION WORK.
06 O. REMOVE ABANDONED UNDERGROUND UTILITIES AND INSTALL ENGINEERED FILL.
07 P. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE SUSPECTED OR
DISCOVERED TO CONTAIN ASBESTOS OR OTHER HAZARDOUS MATERIALS, STOP
11 08
DEMOLITION AND NOTIFY OWNER AND ARCHITECT IMMEDIATELY.
07 Q. REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP MATERIALS WHERE
08 07 07 07 07 07 DAMAGED DUE TO SELECTIVE DEMOLITION ACTIVITIES TO RESTORE ORIGINAL
07 08 08 FIRE RATING UNLESS OTHERWISE INDICATED.
08 08
08 R. THE FOLLOWING DEMOLITION WORK SHALL BE PERFORMED AS PART OF THE
WORK UNDER THE APPROPRIATE PROJECT MANUAL SECTIONS: A.) REMOVAL OF
EXISTING ROOFING. B.) REMOVAL OF EXISTING WINDOWS, TEMPORARY WINDOW
07 OPENING CLOSURES AND OPENING PREPARATION TO RECEIVE NEW WINDOW
UNITS.
08 07 07 07 S. REFER TO WALL SECTIONS NOTED ON DEMOLITION PLANS FOR ADDITIONAL
08 08 06 08 DEMOLITION INFORMATION.
07 07 T. REFER TO PROJECT MANUAL DIVISION 4 FOR SPECIAL REQUIREMENTS
07 REGARDING DISPOSAL OF DEMOLISHED MASONRY RUBBLE.
08
07 07 U. ALL WALL AND FLOOR FINISHES ARE TO REMAIN UNLESS NOTED OTHERWISE.
08 11 11 08
REV. 11/08/05
07
07
08 07
08 KEYNOTES - DEMOLITION
07 08
08
07
08
06 01 07 08 01 REMOVE EXISTING WALL CONSTRUCTION, DOORS AND FRAMES COMPLETELY. F
07
07 08
07 02 REMOVE EXISTING BRICK WIINDOW FILL IN IT'S ENTIRETY.
03 DUCTED FUME HOODS TO BE REMOVED BY THE HAZARDOUS MATERIAL ABATEMENT
3 G

08
07
08
12 12 11
11 12
CONTRACTOR.
04 REMOVE EXISTING BUILT-IN EQUIPMENT/CABINETRY IN IT'S ENTIRETY.
E
2
11 05 REMOVE EXISTING LOOSE EQUIPMENT, MACHINES, FURNITURE AND INSTALLED D
11 MARKERBOARDS STORE AS REQUESTED BY OWNER.
06 EXISTING WOOD FLOORING AND STRUCTURE ABOVE TO REMAIN
06 C
07 07 07 38 07 REMOVE ALL EXISTING MECHANICAL, TIE UP AND SALVAGE LIGHT FIXTURES ONLY
07 07
08 08 08 WHERE CEILING GRID REPLACEMENT OCCUR, WHERE CEILING IS TO REMAIN EXPOSED
11 11
TO DECK, ASSUME NEW MECHANICAL AND OTHER COMPONENTRY IS TO BE DRYFALL
PAINTED TO MATCH EXISTING EXPOSED STRUCTURE. WHERE CEILING IS EXPOSED
B 1
11

1/8"
WOOD TIMBER, COLOR OF DUCTS IS TO BE DETERMINED.
12 12 11 12 08 REMOVE EXISTING ACOUSTICAL TILE CEILING AND SUPPORTS IN IT'S ENTIRETY. TIE UP A
11 07 AND SALVAGE LIGHT FIXTURES AS DESCRIBED IN NOTE 07. ASSUME NEW CEILING
07 GRID AND TILES ARE TO BE INSTALLED AND WILL CONCEAL NEW MECHANICAL
08 07
08 EQUIPMENT..
07 08
07 08 08 N.I.C. KEY PLAN
06 09 REMOVE EXISTING LIGHTING IN THIS SHADED AREA. REFERENCE RCP FOR CEILING IN
THIS AREA.
07
11 11 11 11 10 REMOVE EXISTING FLOORING, BASE AND WALL FINISHES IN THEIR ENTIRETY AND SEAL | DATE 04/01/21
PREPARE FOR NEW.
11 07 08 07 08
07 08 11 DESIGN INTENT IS TO MAINTAIN VERTICAL FACE AND UNDERSIDE OF BULKHEADS/
07 DRYWALL CEILINGS WHERE POSSIBLE AND PATCH TO AS-NEW CONDITION IF ANY
01 08 WORK ABOVE THE CEILING IS REQUIRED, IN LIEU OF REBUILDING IF ANY LIGHT
07 07 07 07 FIXTURES EXIST, SALVAGE AND REUSED IN PATCHED CEILING IF POSSIBLE..
12 REMOVE EXISTING DRYWALL CEILING AND SUPPORTS. REFERENCE RCP FOR FINAL
11 DESIGN INTENT. IF IN EXISTENCE, WALL SCONCES ARE TO REMAIN.. IF CEILING
LIGHTS EXIST, SALVAGE FOR REUSE IN NEW CEILING UNLESS SHOWN OTHERWISE IN
07 07 NEW CEILING PLAN..
06 07 13 EXISTING TO REMAIN.
07 08 08
07 08 08 07 14 REMOVE HORIZONTAL PORTION OF HARDLID CEILINGS FOR HVAC WORK. REMOVE
08 WOOD PANELING IN CEILINGS. EXISTING STEPPED COFFER, DRYWALL WRAPPED
TRUSSES AND VERTICAL PORTIONS OF HARDLID CEILINGS TO REMAIN FOR REUSE.
07 11 15 REMOVE EXISTING CERAMIC TILE ON WALLS AND FLOOR IN ITS ENTIRETY.
08 SHEET ISSUE
16 REMOVE EXISTING LEVEL 2 BRIDGE CONSTRUCTION AND RAILING IN ITS ENTIRETY TO
CREATE OPENING TO BELOW 1 Construction Documents 04/01/21
07 08 07 08 07 17 CAREFULLY SALVAGE ACOUSTICAL PANELS MOUNTED TO WALLS FOR POSSIBLE
07 08 07 REUSE BY OWNER. VERIFY RELOCATION DIRECTION WITH OWNER.
08
08 18 WALLS N THIS AREA REPRESENT TEMPORARY OFFICES CREATED IN INTIAL PHASE OF
11 CONSTRUCTION. THESE ARE TO BE REMOVED, ALONG WITH CEILINGS AND FINISHES
07 08 11
AT CORRECT PHASE TO CONVERT THESE ROOMS TO CLASSROOMS. EXISTING
07 CEILINGS CAN REMAIN AND LIGHTING RECONFIGURED DURING TEMPORARY OFFICE
07 PHASE AND ALL IS TO BE REMOVED FOR FINAL CLASSROOM PHASE.
08 07
06 07 08 07 19 REMOVE EXISTING GLAZING AND FRAMING AS REQUIRED TO ACCEPT NEW
07 08 08
08 MECHANICAL LOUVER.
07
20 REMOVE EXISTING WINDOWS AND FRAMES IN THEIR ENTIRETY.
11 21 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL.
12 12 11 07 07
22 REMOVE EXISTING SKYLIGHT FRAME, GLAZING, AND ACCESSORIES DOWN TO EXISTING
CURB IN ENTIRETY.
07 38 23 REMOVE EXISTING ROOF DUCT CHASE, FRAMING, AND ROOFING IN ENTIRETY.
11
07 08 07 08 07 08 24 REMOVE EXISTING ROOFING, INSULATION, AND CRICKET MATERIAL IN ENTIRETY TO
07 12 RECEIVE NEW ROOF AND FLASHINGS.
07
25 REMOVE EXISTING METAL LADDER, PLATFORM, AND SUPPORTS COMPLETE.
26 REMOVE EXISTING DOOR PANEL AND HARDWARE AT TOP OF PLATFORM, FRAME TO
07 REMAIN.
07 27 REMOVE EXISTING CONCRETE HOUSEKEEPING PAD FLUSH TO SURROUNDING FLOOR
ELEVATION TO RECEIVE NEW HOUSEKEEPING PAD.
07 29 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF ACADEMIC
BUILDING CONSTRUCTION. EXISTING TO REMAIN WITHOUT DISRUPTION IF POSSIBLE.
IF NOT POSSIBLE, ASSUME NARRATIVE FROM 07 AND 08 TO BE APPLIED TO THIS AREA.
30 ALTERNATE BID # A-2: REPLACE EXISTING LINEAR PENDANT WITH NEW SPECIALTY
LIGHTING FOR LIVING WALL PER ELECTRICAL LIGHTING PLANS
31 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF 2020
SUMMER CONSTRUCTION. AS MUCH OF EXISTING CENTER PORTION TO REMAIN
WITHOUT DISRUPTION IF POSSIBLE.
33 REMOVE EXISTING SKYLIGHT AND LIGHTING. REFERENCE ARCHITECTURAL AND
DETAILED SECTIONS FOR ARCHITECTURAL DESIGN INTENT TO DETERMINE EXTENT OF
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
DEMOLITION. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
34 FLOORING TO REMAIN AT STAIRS. REMOVE EXISTING DISPLAY PILASTERS UNDER COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
STAIRS.
35 REMOVE ALL EXISTING CEILING, LIGHTING, REMAINING WALL FINISHES AND FLOOR PROJECT NO. 19010.000
FINISHES. PREP AREA FOR NEW CEILING, FINISHES, HVAC AND FLOOR PLAN LAYOUT
AS NEEDED. SHEET TITLE
36 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL. REMOVE EXSTING LIGHTING IN THIS AREA.
37 INVESTIGATE CONSTRUCTION OF THIS HORIZONTAL BEAM TO DETERMINE FEASIBILITY
LOWER LEVEL 1
OF REMOVING BOTTOM FURRING STRIPS AND RECONSTRUCTION TO MATCH HEIGHT
OF HORIZONTAL BEAM TO
DEMOLITION PLAN
A5 LOWER LEVEL 1 DEMOLITION PLAN 38 PROVIDE ALT. BID NO A-5 TO REMOVE EXISITNG QUARRY TILE ON STAIRS AND
PREPARE FOR NEW TREADS, RISERS, LANDING AND STRINGERS AS REQUIRED PER
4/1/2021 11:29:09 AM

AD-112
1/16" = 1'-0" THE FINISH PLANS. THIS INCLUDES REMOVAL OF PEDESTALS ON LEVEL 1.
39 REMOVE ROOFING, INSULATION, AND STRUCTURE AS REQUIRED FOR NEW ROOF
HATCH.
40 SELECTIVELY DEMO AS REQUIRED FOR HVAC WORK. IF FLOORING ABOVE IS SHEET NUMBER
AFFECTED, CAREFULLY SALVAGE FLOORING FOR REINSTALLATION AFTER HVAC WORK

AD-112
IS COMPLETE.
41 SELECTIVELY DEMO BEHIND COLUMNS TO ALLOW FOR FULL PENETRATION WELDING
OF COLUMN STUBS.
GENERAL DEMOLITION NOTES
A. THESE GENERAL DEMOLITION NOTES APPLY TO DEMOLITION DRAWINGS.
B. FIELD VERIFY CONDITIONS AND COORDINATE DEMOLITION OR REMOVAL WORK
RHIT MOENCH
WITH CORRESPONDING NEW CONSTRUCTION AND WITH APPROPRIATE TRADES
PRIOR TO STARTING DEMOLITION WORK. IF DISCREPANCIES ARE FOUND
BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, NOTIFY
RENOVATION
ARCHITECT IMMEDIATELY.

AD-201
C. OWNER WILL REMOVE LOOSE SALVAGEABLE ITEMS, I.E., EQUIPMENT, FURNITURE,
CABINETRY, FILE CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK,
5500 Wabash Avenue
02 02 02
A3
02 02 PLAQUES, ETC., PRIOR TO CONTRACTOR STARTING DEMOLITION WORK IN EACH
AREA. OWNER WILL STORE AND REINSTALL SUCH ITEMS. [OR] OWNER WILL STORE
MAJORITY OF LOOSE SALVAGEABLE ITEMS IN THE CENTER OF EACH ROOM
Terre Haute, Indiana
CONTAINING SAID ITEMS, I.E., EQUIPMENT, FURNITURE, CABINETRY, FILE
CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK, ETC., PRIOR TO
47803
03 03 03 CONTRACTOR STARTING WORK. CONTRACTOR SHALL PROTECT SUCH ITEMS
03 DURING CONSTRUCTION. Owner
04 01 01
D. DEMOLISHED MATERIALS ARE THE PROPERTY OF THE CONTRACTOR UNLESS
04 07 04 NOTED OTHERWISE AND SHALL BE PROMPTLY DISPOSED OF OFF-SITE.
Rose-Hulman Institute of Technology
05 5500 Wabash Avenue
05 35 05 04 01 E. ITEMS NOTED TO BE REMOVED AND TURNED OVER TO OWNER SHALL BE
18 18 18 18 35
35 35 05 02 DELIVERED AS DIRECTED BY OWNER. Terre Haute, Indiana 47803
02 F. REMOVE ITEMS IN THEIR ENTIRETY UNLESS OTHERWISE INDICATED. 812-877-1511
35 04
18 18 18 18 C3 AD-201 DESCRIPTION OF PRIMARY ITEMS TO BE REMOVED IS GENERAL IN NATURE, AND
07 05 REMOVAL OF SECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS,
AD-201 C6
35 04 01 35 35 ANCHORS, TRIM, ADHESIVE, PIPING, WIRING, ETC., RELATED TO PRIMARY ITEMS
18 04
SHALL BE INCLUDED.
18 18 18 05 05
18 18 01 G. PROTECT EXISTING SURFACES TO REMAIN IN AREAS ADJACENT TO DEMOLITION
18 18 35 35 35 03 WORK.
H. REPAIR FINISHES AND SURFACES LEFT EXPOSED BY DEMOLITION OR REMOVAL OF
01 35 05 N.I.C. EQUIPMENT, USING NEW MATERIALS TO MATCH SURROUNDING SURFACES.
01 01 35 REPAIR EXISTING FLOOR, BASE, WAINSCOT, WALL AND CEILING FINISHES TO
N.I.C.
01 CORRECT DEFECTS EITHER CAUSED OR EXPOSED BY DEMOLITION WORK OR
01 35 35 EQUIPMENT REMOVAL. REPAIRED SURFACES SHALL BE SMOOTH AND

8'-1 3/4"
35 35 01 35 01 01 UNDETECTABLE UNDER FINAL FINISHES. AREAS NOTED ON THE DRAWINGS TO BE Architect
35 04 05 35 REPAIRED OR PATCHED ARE GIVEN FOR REFERENCE AND SHALL NOT BE
05 05 35 05 05 INTERPRETED TO LIMIT THE SCOPE OF WORK. RATIO
04 01
I. PATCH EXISTING FLOOR, WALL, CEILING AND ROOF CONSTRUCTION AT 101 South Pennsylvania Street
05 ABANDONED PENETRATION LOCATIONS WITH NEW MATERIALS AS REQUIRED TO Indianapolis, Indiana 46204
07
35 12 12 RECEIVE NEW FINISHES AND TO MAINTAIN ORIGINAL FIRE RATING OF ASSEMBLY 317-633-4040
17 WHERE APPLICABLE.
01
07 31 11 J. PORTIONS OF EXISTING MASONRY WALLS NOTED TO BE REMOVED AND OPENINGS
04 08 08 TO BE CUT INTO EXISTING MASONRY WALLS SHALL BE REMOVED BACK TO THE
17 01 07 Structural Engineer
05 NEAREST VERTICAL MORTAR JOINT. PROVIDE A MINIMUM BEARING OF 8 AT EACH
35 07 01 08 END FOR NEW MASONRY LINTELS AND FIELD VERIFY FINAL LENGTH. ALLOW A Fink Roberts & Petrie, Inc.
01 MINIMUM OF 4 NEW MASONRY AT JAMB CONDITIONS OR END WALL CONDITIONS
08 07 12 OPEN TO 9449 Priority Way W Dr #200
OF MASONRY WALLS. REFER TO DEMOLITION PLANS FOR LOCATIONS OF WALL,
08 01 LEVEL 2 FLOOR, CEILING OR ROOF OPENINGS. Indianapolis, Indiana 46240
04 07 CEILING 317-872-8400
K. PROVIDE SMOOTH TRANSITIONS BETWEEN FLOOR, WALL AND CEILING SURFACES
OPEN FROM LL1 08
05 PRIOR TO INSTALLING NEW FINISHES WHERE WALLS OR OTHER ITEMS ARE
THROUGH LEVEL 2 REMOVED. FILL FLOOR VOIDS WITH CONCRETE OR MATERIAL MATCHING
35
07 ADJACENT MATERIALS AND LEVEL FLOOR SURFACES TO PROVIDE A SMOOTH
TRANSITION FROM ONE SIDE OF WALL TO THE OTHER WHERE PORTIONS OF Mechanical / Electrical Engineer
07 08
WALLS ARE REMOVED. R.E. Dimond & Associates, Inc.
L. ADDITIONAL FLOOR TILE MAY BE PRESENT BENEATH FINISHES IN ROOMS WITH
EXISTING FLOOR TILE OR CARPET. REMOVE ALL LAYERS OF EXISTING FLOOR 732 N Capitol Avenue
38 38 11 31 11 COVERINGS TO PROVIDE APPROPRIATE SUBSTRATE FOR NEW FLOOR FINISHES. Indianapolis, Indiana 46204
07 08 M. SELECTIVE DEMOLITION FOR INSTALLATION OF NEW MECHANICAL OR ELECTRICAL 317-634-4672
17 WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR TRADE
REQUIRING THE DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, FLOOR
SLAB AND PAVEMENT CUTTING FOR UNDERGROUND PIPING, CORING FOR WALL
11 AND FLOOR PENETRATIONS, ROOF PENETRATIONS, ETC. REFER TO MECHANICAL
07 08 07 07
AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION.
07 08 08
N. DISCONNECT AND CAP-OFF OR REMOVE OBSOLETE EXISTING UTILITY AND
08 SERVICE LINES PRIOR TO STARTING DEMOLITION WORK.
07 O. REMOVE ABANDONED UNDERGROUND UTILITIES AND INSTALL ENGINEERED FILL.
07 08 06 07
08 07 08 07 08 P. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE SUSPECTED OR
OPEN TO 07 07 01 08 DISCOVERED TO CONTAIN ASBESTOS OR OTHER HAZARDOUS MATERIALS, STOP
LEVEL 2 08 DEMOLITION AND NOTIFY OWNER AND ARCHITECT IMMEDIATELY.
CEILING 08 07 Q. REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP MATERIALS WHERE
07 11 08 DAMAGED DUE TO SELECTIVE DEMOLITION ACTIVITIES TO RESTORE ORIGINAL
07 FIRE RATING UNLESS OTHERWISE INDICATED.
07 08 11 11 08 R. THE FOLLOWING DEMOLITION WORK SHALL BE PERFORMED AS PART OF THE
WORK UNDER THE APPROPRIATE PROJECT MANUAL SECTIONS: A.) REMOVAL OF
EXISTING ROOFING. B.) REMOVAL OF EXISTING WINDOWS, TEMPORARY WINDOW
11
OPENING CLOSURES AND OPENING PREPARATION TO RECEIVE NEW WINDOW
06 UNITS.
07
S. REFER TO WALL SECTIONS NOTED ON DEMOLITION PLANS FOR ADDITIONAL
07 08 DEMOLITION INFORMATION.
DESIGN LAB
T. REFER TO PROJECT MANUAL DIVISION 4 FOR SPECIAL REQUIREMENTS
07 08 D101 REGARDING DISPOSAL OF DEMOLISHED MASONRY RUBBLE.
07 08
08 U. ALL WALL AND FLOOR FINISHES ARE TO REMAIN UNLESS NOTED OTHERWISE.
08 01 07
OPEN TO 07
LEVEL 2 07 01 08
07 08 REV. 11/08/05
CEILING 07 08
01 08
08 07 KEYNOTES - DEMOLITION
07
07 08
11
01
07 01 REMOVE EXISTING WALL CONSTRUCTION, DOORS AND FRAMES COMPLETELY.
07 08 01 F
08
06
07
07
01 08
MECHATRONICS
C111
08 02 REMOVE EXISTING BRICK WIINDOW FILL IN IT'S ENTIRETY.
03 DUCTED FUME HOODS TO BE REMOVED BY THE HAZARDOUS MATERIAL ABATEMENT
3 G

07 08
07
01 07 08
CONTRACTOR.
04 REMOVE EXISTING BUILT-IN EQUIPMENT/CABINETRY IN IT'S ENTIRETY.
E
2
07
OPEN TO 05 REMOVE EXISTING LOOSE EQUIPMENT, MACHINES, FURNITURE AND INSTALLED D
LEVEL 2 08 MARKERBOARDS STORE AS REQUESTED BY OWNER.
12 11 11
CEILING 08 01 06 EXISTING WOOD FLOORING AND STRUCTURE ABOVE TO REMAIN
OPEN TO
16 LEVEL 2 07 07 REMOVE ALL EXISTING MECHANICAL, TIE UP AND SALVAGE LIGHT FIXTURES ONLY C
07 11 38 38 07
CEILING 08 WHERE CEILING GRID REPLACEMENT OCCUR, WHERE CEILING IS TO REMAIN EXPOSED

11 11
08 TO DECK, ASSUME NEW MECHANICAL AND OTHER COMPONENTRY IS TO BE DRYFALL
PAINTED TO MATCH EXISTING EXPOSED STRUCTURE. WHERE CEILING IS EXPOSED B 1
11 WOOD TIMBER, COLOR OF DUCTS IS TO BE DETERMINED.
08 REMOVE EXISTING ACOUSTICAL TILE CEILING AND SUPPORTS IN IT'S ENTIRETY. TIE UP A
12 11 AND SALVAGE LIGHT FIXTURES AS DESCRIBED IN NOTE 07. ASSUME NEW CEILING
11 12 GRID AND TILES ARE TO BE INSTALLED AND WILL CONCEAL NEW MECHANICAL
08 07 08 07 EQUIPMENT..
N.I.C. 09 REMOVE EXISTING LIGHTING IN THIS SHADED AREA. REFERENCE RCP FOR CEILING IN KEY PLAN
07 08 07 08 07 08 THIS AREA.
OPEN TO 10 REMOVE EXISTING FLOORING, BASE AND WALL FINISHES IN THEIR ENTIRETY AND
LEVEL 2 08 SEAL | DATE 04/01/21
01 01 PREPARE FOR NEW.
CEILING 07 07 08
11 DESIGN INTENT IS TO MAINTAIN VERTICAL FACE AND UNDERSIDE OF BULKHEADS/
07 08 07 08 DRYWALL CEILINGS WHERE POSSIBLE AND PATCH TO AS-NEW CONDITION IF ANY
07 WORK ABOVE THE CEILING IS REQUIRED, IN LIEU OF REBUILDING IF ANY LIGHT
07 08 07 08
01 07 FIXTURES EXIST, SALVAGE AND REUSED IN PATCHED CEILING IF POSSIBLE..
01 12 REMOVE EXISTING DRYWALL CEILING AND SUPPORTS. REFERENCE RCP FOR FINAL
DESIGN INTENT. IF IN EXISTENCE, WALL SCONCES ARE TO REMAIN.. IF CEILING
LIGHTS EXIST, SALVAGE FOR REUSE IN NEW CEILING UNLESS SHOWN OTHERWISE IN
38 07 NEW CEILING PLAN..
06 13 EXISTING TO REMAIN.
01
14 REMOVE HORIZONTAL PORTION OF HARDLID CEILINGS FOR HVAC WORK. REMOVE
07 08 07 08 WOOD PANELING IN CEILINGS. EXISTING STEPPED COFFER, DRYWALL WRAPPED
11 12 11
TRUSSES AND VERTICAL PORTIONS OF HARDLID CEILINGS TO REMAIN FOR REUSE.
11 15 REMOVE EXISTING CERAMIC TILE ON WALLS AND FLOOR IN ITS ENTIRETY.
12 07 16 REMOVE EXISTING LEVEL 2 BRIDGE CONSTRUCTION AND RAILING IN ITS ENTIRETY TO SHEET ISSUE
08 CREATE OPENING TO BELOW 1 Construction Documents 04/01/21
07
01 07 08 17 CAREFULLY SALVAGE ACOUSTICAL PANELS MOUNTED TO WALLS FOR POSSIBLE
08 REUSE BY OWNER. VERIFY RELOCATION DIRECTION WITH OWNER.
07 11
11 01 18 WALLS N THIS AREA REPRESENT TEMPORARY OFFICES CREATED IN INTIAL PHASE OF
08 12 12 CONSTRUCTION. THESE ARE TO BE REMOVED, ALONG WITH CEILINGS AND FINISHES
OPEN TO AT CORRECT PHASE TO CONVERT THESE ROOMS TO CLASSROOMS. EXISTING
LEVEL 2 08 CEILINGS CAN REMAIN AND LIGHTING RECONFIGURED DURING TEMPORARY OFFICE
CEILING 08 08 PHASE AND ALL IS TO BE REMOVED FOR FINAL CLASSROOM PHASE.
07
08 08 07 07 07 19 REMOVE EXISTING GLAZING AND FRAMING AS REQUIRED TO ACCEPT NEW
01 07 08 08 MECHANICAL LOUVER.
07 08
07 20 REMOVE EXISTING WINDOWS AND FRAMES IN THEIR ENTIRETY.
07
14 21 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
06 STRUCTURAL.
01 11 11 22 REMOVE EXISTING SKYLIGHT FRAME, GLAZING, AND ACCESSORIES DOWN TO EXISTING
CURB IN ENTIRETY.
OPEN TO
38 BELOW 23 REMOVE EXISTING ROOF DUCT CHASE, FRAMING, AND ROOFING IN ENTIRETY.
11 11 12 12
24 REMOVE EXISTING ROOFING, INSULATION, AND CRICKET MATERIAL IN ENTIRETY TO
RECEIVE NEW ROOF AND FLASHINGS.
25 REMOVE EXISTING METAL LADDER, PLATFORM, AND SUPPORTS COMPLETE.
3'-0"

3'-0" 26 REMOVE EXISTING DOOR PANEL AND HARDWARE AT TOP OF PLATFORM, FRAME TO
07 36 3'-0" 21 13 08 07 REMAIN.
21 06 07
3'-0"

06 27 REMOVE EXISTING CONCRETE HOUSEKEEPING PAD FLUSH TO SURROUNDING FLOOR


12 ELEVATION TO RECEIVE NEW HOUSEKEEPING PAD.
06
01 08 07 06 07
08 01 08 07 29 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF ACADEMIC
06 08 07 08 07 06 07 BUILDING CONSTRUCTION. EXISTING TO REMAIN WITHOUT DISRUPTION IF POSSIBLE.
07 07 08 07 06 40
IF NOT POSSIBLE, ASSUME NARRATIVE FROM 07 AND 08 TO BE APPLIED TO THIS AREA.
3'-0"

06 30 ALTERNATE BID # A-2: REPLACE EXISTING LINEAR PENDANT WITH NEW SPECIALTY
21 08 07 40 06 07 LIGHTING FOR LIVING WALL PER ELECTRICAL LIGHTING PLANS
3'-0"
08 31 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF 2020
08 08 07 08 07
07 06 SUMMER CONSTRUCTION. AS MUCH OF EXISTING CENTER PORTION TO REMAIN
06 WITHOUT DISRUPTION IF POSSIBLE.
07 08 07 08 07 08 07 13 07 06 06 07
08 33 REMOVE EXISTING SKYLIGHT AND LIGHTING. REFERENCE ARCHITECTURAL AND
DETAILED SECTIONS FOR ARCHITECTURAL DESIGN INTENT TO DETERMINE EXTENT OF
07 08 07 DEMOLITION. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
06 06 40 06 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
34 FLOORING TO REMAIN AT STAIRS. REMOVE EXISTING DISPLAY PILASTERS UNDER DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
STAIRS.
06 06 06 06 06 06 08 07 06 06 06 06 06 06 35 REMOVE ALL EXISTING CEILING, LIGHTING, REMAINING WALL FINISHES AND FLOOR
07 07 07 07 07 07 07 07 07 07 07 07 FINISHES. PREP AREA FOR NEW CEILING, FINISHES, HVAC AND FLOOR PLAN LAYOUT PROJECT NO. 19010.000
AS NEEDED. SHEET TITLE
36 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL. REMOVE EXSTING LIGHTING IN THIS AREA.
37 INVESTIGATE CONSTRUCTION OF THIS HORIZONTAL BEAM TO DETERMINE FEASIBILITY
FIRST LEVEL
OF REMOVING BOTTOM FURRING STRIPS AND RECONSTRUCTION TO MATCH HEIGHT
OF HORIZONTAL BEAM TO DEMOLITION PLAN
38 PROVIDE ALT. BID NO A-5 TO REMOVE EXISITNG QUARRY TILE ON STAIRS AND
PREPARE FOR NEW TREADS, RISERS, LANDING AND STRINGERS AS REQUIRED PER
FIRST LEVEL DEMOLITION PLAN
4/1/2021 11:29:18 AM

A5 THE FINISH PLANS. THIS INCLUDES REMOVAL OF PEDESTALS ON LEVEL 1.


AD-113
1/16" = 1'-0" 39 REMOVE ROOFING, INSULATION, AND STRUCTURE AS REQUIRED FOR NEW ROOF
HATCH.
40 SELECTIVELY DEMO AS REQUIRED FOR HVAC WORK. IF FLOORING ABOVE IS
SHEET NUMBER
AFFECTED, CAREFULLY SALVAGE FLOORING FOR REINSTALLATION AFTER HVAC WORK
IS COMPLETE.
41 SELECTIVELY DEMO BEHIND COLUMNS TO ALLOW FOR FULL PENETRATION WELDING
OF COLUMN STUBS. AD-113
GENERAL DEMOLITION NOTES
A. THESE GENERAL DEMOLITION NOTES APPLY TO DEMOLITION DRAWINGS.
B. FIELD VERIFY CONDITIONS AND COORDINATE DEMOLITION OR REMOVAL WORK
RHIT MOENCH
WITH CORRESPONDING NEW CONSTRUCTION AND WITH APPROPRIATE TRADES
PRIOR TO STARTING DEMOLITION WORK. IF DISCREPANCIES ARE FOUND
BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, NOTIFY
RENOVATION
ARCHITECT IMMEDIATELY.

AD-201
C. OWNER WILL REMOVE LOOSE SALVAGEABLE ITEMS, I.E., EQUIPMENT, FURNITURE,
CABINETRY, FILE CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK,
5500 Wabash Avenue
A3
PLAQUES, ETC., PRIOR TO CONTRACTOR STARTING DEMOLITION WORK IN EACH
AREA. OWNER WILL STORE AND REINSTALL SUCH ITEMS. [OR] OWNER WILL STORE
MAJORITY OF LOOSE SALVAGEABLE ITEMS IN THE CENTER OF EACH ROOM
Terre Haute, Indiana
CONTAINING SAID ITEMS, I.E., EQUIPMENT, FURNITURE, CABINETRY, FILE
CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK, ETC., PRIOR TO
47803
CONTRACTOR STARTING WORK. CONTRACTOR SHALL PROTECT SUCH ITEMS
DURING CONSTRUCTION. Owner
D. DEMOLISHED MATERIALS ARE THE PROPERTY OF THE CONTRACTOR UNLESS
NOTED OTHERWISE AND SHALL BE PROMPTLY DISPOSED OF OFF-SITE.
Rose-Hulman Institute of Technology
E. ITEMS NOTED TO BE REMOVED AND TURNED OVER TO OWNER SHALL BE 5500 Wabash Avenue
DELIVERED AS DIRECTED BY OWNER. Terre Haute, Indiana 47803
F. REMOVE ITEMS IN THEIR ENTIRETY UNLESS OTHERWISE INDICATED. 812-877-1511
C3 AD-201 DESCRIPTION OF PRIMARY ITEMS TO BE REMOVED IS GENERAL IN NATURE, AND
AD-201 C6 REMOVAL OF SECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS,
ANCHORS, TRIM, ADHESIVE, PIPING, WIRING, ETC., RELATED TO PRIMARY ITEMS
SHALL BE INCLUDED.
G. PROTECT EXISTING SURFACES TO REMAIN IN AREAS ADJACENT TO DEMOLITION
WORK.
N.I.C. H. REPAIR FINISHES AND SURFACES LEFT EXPOSED BY DEMOLITION OR REMOVAL OF
39 EQUIPMENT, USING NEW MATERIALS TO MATCH SURROUNDING SURFACES.
REPAIR EXISTING FLOOR, BASE, WAINSCOT, WALL AND CEILING FINISHES TO
CORRECT DEFECTS EITHER CAUSED OR EXPOSED BY DEMOLITION WORK OR
EQUIPMENT REMOVAL. REPAIRED SURFACES SHALL BE SMOOTH AND
UNDETECTABLE UNDER FINAL FINISHES. AREAS NOTED ON THE DRAWINGS TO BE Architect
REPAIRED OR PATCHED ARE GIVEN FOR REFERENCE AND SHALL NOT BE
INTERPRETED TO LIMIT THE SCOPE OF WORK. RATIO
I. PATCH EXISTING FLOOR, WALL, CEILING AND ROOF CONSTRUCTION AT 101 South Pennsylvania Street
ABANDONED PENETRATION LOCATIONS WITH NEW MATERIALS AS REQUIRED TO Indianapolis, Indiana 46204
11 12 RECEIVE NEW FINISHES AND TO MAINTAIN ORIGINAL FIRE RATING OF ASSEMBLY 317-633-4040
01 WHERE APPLICABLE.
12
07 01 J. PORTIONS OF EXISTING MASONRY WALLS NOTED TO BE REMOVED AND OPENINGS
08 TO BE CUT INTO EXISTING MASONRY WALLS SHALL BE REMOVED BACK TO THE
01 Structural Engineer
07 NEAREST VERTICAL MORTAR JOINT. PROVIDE A MINIMUM BEARING OF 8 AT EACH
13 END FOR NEW MASONRY LINTELS AND FIELD VERIFY FINAL LENGTH. ALLOW A Fink Roberts & Petrie, Inc.
REMOVE MINIMUM OF 4 NEW MASONRY AT JAMB CONDITIONS OR END WALL CONDITIONS
01 OF MASONRY WALLS. REFER TO DEMOLITION PLANS FOR LOCATIONS OF WALL, 9449 Priority Way W Dr #200
STAIRS &
RAILING FLOOR, CEILING OR ROOF OPENINGS. Indianapolis, Indiana 46240
05 05 K. PROVIDE SMOOTH TRANSITIONS BETWEEN FLOOR, WALL AND CEILING SURFACES 317-872-8400
12 20 05 07
below 05 09 08 01 31 PRIOR TO INSTALLING NEW FINISHES WHERE WALLS OR OTHER ITEMS ARE
08
REMOVED. FILL FLOOR VOIDS WITH CONCRETE OR MATERIAL MATCHING
11
ADJACENT MATERIALS AND LEVEL FLOOR SURFACES TO PROVIDE A SMOOTH
13 TRANSITION FROM ONE SIDE OF WALL TO THE OTHER WHERE PORTIONS OF Mechanical / Electrical Engineer
W01 W02
10 04 15 04 04 WALLS ARE REMOVED. R.E. Dimond & Associates, Inc.
11 L. ADDITIONAL FLOOR TILE MAY BE PRESENT BENEATH FINISHES IN ROOMS WITH
12 12 05 12 EXISTING FLOOR TILE OR CARPET. REMOVE ALL LAYERS OF EXISTING FLOOR 732 N Capitol Avenue
OPEN TO BELOW OPEN TO BELOW Indianapolis, Indiana 46204
38 11 07 10 05 COVERINGS TO PROVIDE APPROPRIATE SUBSTRATE FOR NEW FLOOR FINISHES.
11 11 M. SELECTIVE DEMOLITION FOR INSTALLATION OF NEW MECHANICAL OR ELECTRICAL 317-634-4672
30 30 15 04 WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR TRADE
04 04
REQUIRING THE DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, FLOOR
SLAB AND PAVEMENT CUTTING FOR UNDERGROUND PIPING, CORING FOR WALL
08 07 01 07 AND FLOOR PENETRATIONS, ROOF PENETRATIONS, ETC. REFER TO MECHANICAL
01 07 07 11 11
08 08 08 AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION.
01 N. DISCONNECT AND CAP-OFF OR REMOVE OBSOLETE EXISTING UTILITY AND
07 07 07 07 07 01 07 SERVICE LINES PRIOR TO STARTING DEMOLITION WORK.
08 08 08 08 O. REMOVE ABANDONED UNDERGROUND UTILITIES AND INSTALL ENGINEERED FILL.
08 08
41 41 P. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE SUSPECTED OR
OPEN TO BELOW DISCOVERED TO CONTAIN ASBESTOS OR OTHER HAZARDOUS MATERIALS, STOP
07 07 07 07 DEMOLITION AND NOTIFY OWNER AND ARCHITECT IMMEDIATELY.
08 07 Q. REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP MATERIALS WHERE
08 08 08
07 DAMAGED DUE TO SELECTIVE DEMOLITION ACTIVITIES TO RESTORE ORIGINAL
08
07 07 FIRE RATING UNLESS OTHERWISE INDICATED.
07 07 08 01 07 R. THE FOLLOWING DEMOLITION WORK SHALL BE PERFORMED AS PART OF THE
08 08
08 08 01 08 WORK UNDER THE APPROPRIATE PROJECT MANUAL SECTIONS: A.) REMOVAL OF
41 41
33 EXISTING ROOFING. B.) REMOVAL OF EXISTING WINDOWS, TEMPORARY WINDOW
OPENING CLOSURES AND OPENING PREPARATION TO RECEIVE NEW WINDOW
07 07 01 01 07
07 UNITS.
08 08 08 S. REFER TO WALL SECTIONS NOTED ON DEMOLITION PLANS FOR ADDITIONAL
01 08 07 07 DEMOLITION INFORMATION.
07
08 08 07 07 T. REFER TO PROJECT MANUAL DIVISION 4 FOR SPECIAL REQUIREMENTS
08
08 REGARDING DISPOSAL OF DEMOLISHED MASONRY RUBBLE.
01 08
OPEN TO BELOW 41 41 U. ALL WALL AND FLOOR FINISHES ARE TO REMAIN UNLESS NOTED OTHERWISE.

07 07 08 07 07 REV. 11/08/05
08 07
08 08
07
07 07
08 KEYNOTES - DEMOLITION
08 07 01 07
07 08 08
01 08 41 08 01 08
41

01 07
01 REMOVE EXISTING WALL CONSTRUCTION, DOORS AND FRAMES COMPLETELY.
F
07 07
01
07
08 02 REMOVE EXISTING BRICK WIINDOW FILL IN IT'S ENTIRETY.
03 DUCTED FUME HOODS TO BE REMOVED BY THE HAZARDOUS MATERIAL ABATEMENT
3 G
07 01
41 41
01
08 08 07
08
CONTRACTOR.
04 REMOVE EXISTING BUILT-IN EQUIPMENT/CABINETRY IN IT'S ENTIRETY.
E
2
OPEN TO BELOW
05 REMOVE EXISTING LOOSE EQUIPMENT, MACHINES, FURNITURE AND INSTALLED D
11 01 01 07 MARKERBOARDS STORE AS REQUESTED BY OWNER.
16 12 09
08 06 EXISTING WOOD FLOORING AND STRUCTURE ABOVE TO REMAIN
12 09 38 07 07 REMOVE ALL EXISTING MECHANICAL, TIE UP AND SALVAGE LIGHT FIXTURES ONLY C
11
29 08 WHERE CEILING GRID REPLACEMENT OCCUR, WHERE CEILING IS TO REMAIN EXPOSED

41
33
41 01
07
01 08
TO DECK, ASSUME NEW MECHANICAL AND OTHER COMPONENTRY IS TO BE DRYFALL
PAINTED TO MATCH EXISTING EXPOSED STRUCTURE. WHERE CEILING IS EXPOSED
B 1
WOOD TIMBER, COLOR OF DUCTS IS TO BE DETERMINED.
07 08 08 REMOVE EXISTING ACOUSTICAL TILE CEILING AND SUPPORTS IN IT'S ENTIRETY. TIE UP A
AND SALVAGE LIGHT FIXTURES AS DESCRIBED IN NOTE 07. ASSUME NEW CEILING
31 GRID AND TILES ARE TO BE INSTALLED AND WILL CONCEAL NEW MECHANICAL
07 07 EQUIPMENT..
07 08 08 N.I.C. KEY PLAN
09 REMOVE EXISTING LIGHTING IN THIS SHADED AREA. REFERENCE RCP FOR CEILING IN
41 41 THIS AREA.
OPEN TO BELOW
10 REMOVE EXISTING FLOORING, BASE AND WALL FINISHES IN THEIR ENTIRETY AND SEAL | DATE 04/01/21
PREPARE FOR NEW.
11 DESIGN INTENT IS TO MAINTAIN VERTICAL FACE AND UNDERSIDE OF BULKHEADS/
07 01 07
33 DRYWALL CEILINGS WHERE POSSIBLE AND PATCH TO AS-NEW CONDITION IF ANY
07 07 08 08 WORK ABOVE THE CEILING IS REQUIRED, IN LIEU OF REBUILDING IF ANY LIGHT
01 01 FIXTURES EXIST, SALVAGE AND REUSED IN PATCHED CEILING IF POSSIBLE..
41 41 12 REMOVE EXISTING DRYWALL CEILING AND SUPPORTS. REFERENCE RCP FOR FINAL
DESIGN INTENT. IF IN EXISTENCE, WALL SCONCES ARE TO REMAIN.. IF CEILING
LIGHTS EXIST, SALVAGE FOR REUSE IN NEW CEILING UNLESS SHOWN OTHERWISE IN
38 13 NEW CEILING PLAN..
13 EXISTING TO REMAIN.
13 07
14 REMOVE HORIZONTAL PORTION OF HARDLID CEILINGS FOR HVAC WORK. REMOVE
OPEN TO BELOW WOOD PANELING IN CEILINGS. EXISTING STEPPED COFFER, DRYWALL WRAPPED
07 08 07 08 01
41 TRUSSES AND VERTICAL PORTIONS OF HARDLID CEILINGS TO REMAIN FOR REUSE.
41
14 15 REMOVE EXISTING CERAMIC TILE ON WALLS AND FLOOR IN ITS ENTIRETY.
OPEN TO BELOW SHEET ISSUE
16 REMOVE EXISTING LEVEL 2 BRIDGE CONSTRUCTION AND RAILING IN ITS ENTIRETY TO
07 01 CREATE OPENING TO BELOW 1 Construction Documents 04/01/21
07 08 07 07
08 17 CAREFULLY SALVAGE ACOUSTICAL PANELS MOUNTED TO WALLS FOR POSSIBLE
08 08 07
REUSE BY OWNER. VERIFY RELOCATION DIRECTION WITH OWNER.
11 01 18 WALLS N THIS AREA REPRESENT TEMPORARY OFFICES CREATED IN INTIAL PHASE OF
14 41 41 CONSTRUCTION. THESE ARE TO BE REMOVED, ALONG WITH CEILINGS AND FINISHES
AT CORRECT PHASE TO CONVERT THESE ROOMS TO CLASSROOMS. EXISTING
CEILINGS CAN REMAIN AND LIGHTING RECONFIGURED DURING TEMPORARY OFFICE
PHASE AND ALL IS TO BE REMOVED FOR FINAL CLASSROOM PHASE.
14 07 07 19 REMOVE EXISTING GLAZING AND FRAMING AS REQUIRED TO ACCEPT NEW
08 08 MECHANICAL LOUVER.
20 REMOVE EXISTING WINDOWS AND FRAMES IN THEIR ENTIRETY.
41 41 21 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL.
33 22 REMOVE EXISTING SKYLIGHT FRAME, GLAZING, AND ACCESSORIES DOWN TO EXISTING
CURB IN ENTIRETY.
14 11 11 OPEN TO BELOW
07 01 38 23 REMOVE EXISTING ROOF DUCT CHASE, FRAMING, AND ROOFING IN ENTIRETY.
01 41 24 REMOVE EXISTING ROOFING, INSULATION, AND CRICKET MATERIAL IN ENTIRETY TO
41 RECEIVE NEW ROOF AND FLASHINGS.
38
25 REMOVE EXISTING METAL LADDER, PLATFORM, AND SUPPORTS COMPLETE.
26 REMOVE EXISTING DOOR PANEL AND HARDWARE AT TOP OF PLATFORM, FRAME TO
31 REMAIN.
11 B2
AD-114 27 REMOVE EXISTING CONCRETE HOUSEKEEPING PAD FLUSH TO SURROUNDING FLOOR
08 08 21
ELEVATION TO RECEIVE NEW HOUSEKEEPING PAD.
07 07 07 ABOVE 08
07 08 08 07 29 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF ACADEMIC
10 10 07 BUILDING CONSTRUCTION. EXISTING TO REMAIN WITHOUT DISRUPTION IF POSSIBLE.
08
05 09 05 09 IF NOT POSSIBLE, ASSUME NARRATIVE FROM 07 AND 08 TO BE APPLIED TO THIS AREA.
08 30 ALTERNATE BID # A-2: REPLACE EXISTING LINEAR PENDANT WITH NEW SPECIALTY
08 21 10 09 09 10 07 07 07 07 LIGHTING FOR LIVING WALL PER ELECTRICAL LIGHTING PLANS
07 08
31 08 08 08 31 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF 2020
07 08 SUMMER CONSTRUCTION. AS MUCH OF EXISTING CENTER PORTION TO REMAIN
10 09 09 10
MECHANICAL 21 WITHOUT DISRUPTION IF POSSIBLE.
07
ROOM 31 01 31 33 REMOVE EXISTING SKYLIGHT AND LIGHTING. REFERENCE ARCHITECTURAL AND
08
A301 DETAILED SECTIONS FOR ARCHITECTURAL DESIGN INTENT TO DETERMINE EXTENT OF
07 DEMOLITION. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
27 11 11 11 11 11 11 11 11 08 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
34 FLOORING TO REMAIN AT STAIRS. REMOVE EXISTING DISPLAY PILASTERS UNDER DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
07 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
STAIRS.
25 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08
01 08 35 REMOVE ALL EXISTING CEILING, LIGHTING, REMAINING WALL FINISHES AND FLOOR
07 07 07 07 07 07 07 07 07 07 07 07 PROJECT NO. 19010.000
26 07 07 07 07 FINISHES. PREP AREA FOR NEW CEILING, FINISHES, HVAC AND FLOOR PLAN LAYOUT
AS NEEDED. SHEET TITLE
36 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL. REMOVE EXSTING LIGHTING IN THIS AREA.
37 INVESTIGATE CONSTRUCTION OF THIS HORIZONTAL BEAM TO DETERMINE FEASIBILITY
SECOND LEVEL
OF REMOVING BOTTOM FURRING STRIPS AND RECONSTRUCTION TO MATCH HEIGHT
OF HORIZONTAL BEAM TO DEMOLITION PLAN
38 PROVIDE ALT. BID NO A-5 TO REMOVE EXISITNG QUARRY TILE ON STAIRS AND
B2 ATTIC MEZZANINE DEMOLITION PLAN A5 SECOND LEVEL DEMOLITION PLAN PREPARE FOR NEW TREADS, RISERS, LANDING AND STRINGERS AS REQUIRED PER
4/1/2021 11:29:30 AM

AD-114 AD-114
THE FINISH PLANS. THIS INCLUDES REMOVAL OF PEDESTALS ON LEVEL 1.
3/32" = 1'-0" 1/16" = 1'-0" 39 REMOVE ROOFING, INSULATION, AND STRUCTURE AS REQUIRED FOR NEW ROOF
HATCH.
40 SELECTIVELY DEMO AS REQUIRED FOR HVAC WORK. IF FLOORING ABOVE IS SHEET NUMBER
AFFECTED, CAREFULLY SALVAGE FLOORING FOR REINSTALLATION AFTER HVAC WORK
IS COMPLETE.
41 SELECTIVELY DEMO BEHIND COLUMNS TO ALLOW FOR FULL PENETRATION WELDING
OF COLUMN STUBS. AD-114
GENERAL DEMOLITION NOTES
A. THESE GENERAL DEMOLITION NOTES APPLY TO DEMOLITION DRAWINGS.
B. FIELD VERIFY CONDITIONS AND COORDINATE DEMOLITION OR REMOVAL WORK
RHIT MOENCH
WITH CORRESPONDING NEW CONSTRUCTION AND WITH APPROPRIATE TRADES
PRIOR TO STARTING DEMOLITION WORK. IF DISCREPANCIES ARE FOUND
BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, NOTIFY
RENOVATION
ARCHITECT IMMEDIATELY.

AD-201
C. OWNER WILL REMOVE LOOSE SALVAGEABLE ITEMS, I.E., EQUIPMENT, FURNITURE,
CABINETRY, FILE CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK,
5500 Wabash Avenue
A3
PLAQUES, ETC., PRIOR TO CONTRACTOR STARTING DEMOLITION WORK IN EACH
AREA. OWNER WILL STORE AND REINSTALL SUCH ITEMS. [OR] OWNER WILL STORE
MAJORITY OF LOOSE SALVAGEABLE ITEMS IN THE CENTER OF EACH ROOM
Terre Haute, Indiana
CONTAINING SAID ITEMS, I.E., EQUIPMENT, FURNITURE, CABINETRY, FILE
CABINETS, WALL-MOUNTED PROJECTION SCREENS, ARTWORK, ETC., PRIOR TO
47803
CONTRACTOR STARTING WORK. CONTRACTOR SHALL PROTECT SUCH ITEMS
DURING CONSTRUCTION. Owner
D. DEMOLISHED MATERIALS ARE THE PROPERTY OF THE CONTRACTOR UNLESS
NOTED OTHERWISE AND SHALL BE PROMPTLY DISPOSED OF OFF-SITE.
Rose-Hulman Institute of Technology
E. ITEMS NOTED TO BE REMOVED AND TURNED OVER TO OWNER SHALL BE 5500 Wabash Avenue
DELIVERED AS DIRECTED BY OWNER. Terre Haute, Indiana 47803
F. REMOVE ITEMS IN THEIR ENTIRETY UNLESS OTHERWISE INDICATED. 812-877-1511
C3 AD-201 DESCRIPTION OF PRIMARY ITEMS TO BE REMOVED IS GENERAL IN NATURE, AND
AD-201 C6 REMOVAL OF SECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS,
ANCHORS, TRIM, ADHESIVE, PIPING, WIRING, ETC., RELATED TO PRIMARY ITEMS
SHALL BE INCLUDED.
G. PROTECT EXISTING SURFACES TO REMAIN IN AREAS ADJACENT TO DEMOLITION
WORK.
H. REPAIR FINISHES AND SURFACES LEFT EXPOSED BY DEMOLITION OR REMOVAL OF
EQUIPMENT, USING NEW MATERIALS TO MATCH SURROUNDING SURFACES.
REPAIR EXISTING FLOOR, BASE, WAINSCOT, WALL AND CEILING FINISHES TO
CORRECT DEFECTS EITHER CAUSED OR EXPOSED BY DEMOLITION WORK OR
EQUIPMENT REMOVAL. REPAIRED SURFACES SHALL BE SMOOTH AND
UNDETECTABLE UNDER FINAL FINISHES. AREAS NOTED ON THE DRAWINGS TO BE Architect
REPAIRED OR PATCHED ARE GIVEN FOR REFERENCE AND SHALL NOT BE
INTERPRETED TO LIMIT THE SCOPE OF WORK. RATIO
I. PATCH EXISTING FLOOR, WALL, CEILING AND ROOF CONSTRUCTION AT 101 South Pennsylvania Street
ABANDONED PENETRATION LOCATIONS WITH NEW MATERIALS AS REQUIRED TO Indianapolis, Indiana 46204
24 RECEIVE NEW FINISHES AND TO MAINTAIN ORIGINAL FIRE RATING OF ASSEMBLY 317-633-4040
WHERE APPLICABLE.
J. PORTIONS OF EXISTING MASONRY WALLS NOTED TO BE REMOVED AND OPENINGS
22 24 TO BE CUT INTO EXISTING MASONRY WALLS SHALL BE REMOVED BACK TO THE
NEAREST VERTICAL MORTAR JOINT. PROVIDE A MINIMUM BEARING OF 8 AT EACH Structural Engineer
END FOR NEW MASONRY LINTELS AND FIELD VERIFY FINAL LENGTH. ALLOW A Fink Roberts & Petrie, Inc.
24 MINIMUM OF 4 NEW MASONRY AT JAMB CONDITIONS OR END WALL CONDITIONS
OF MASONRY WALLS. REFER TO DEMOLITION PLANS FOR LOCATIONS OF WALL, 9449 Priority Way W Dr #200
FLOOR, CEILING OR ROOF OPENINGS. Indianapolis, Indiana 46240
23 24 K. PROVIDE SMOOTH TRANSITIONS BETWEEN FLOOR, WALL AND CEILING SURFACES 317-872-8400
8 PRIOR TO INSTALLING NEW FINISHES WHERE WALLS OR OTHER ITEMS ARE
REMOVED. FILL FLOOR VOIDS WITH CONCRETE OR MATERIAL MATCHING
ADJACENT MATERIALS AND LEVEL FLOOR SURFACES TO PROVIDE A SMOOTH
TRANSITION FROM ONE SIDE OF WALL TO THE OTHER WHERE PORTIONS OF Mechanical / Electrical Engineer
W01 W02 3
WALLS ARE REMOVED. R.E. Dimond & Associates, Inc.
L. ADDITIONAL FLOOR TILE MAY BE PRESENT BENEATH FINISHES IN ROOMS WITH
EXISTING FLOOR TILE OR CARPET. REMOVE ALL LAYERS OF EXISTING FLOOR 732 N Capitol Avenue
COVERINGS TO PROVIDE APPROPRIATE SUBSTRATE FOR NEW FLOOR FINISHES. Indianapolis, Indiana 46204
M. SELECTIVE DEMOLITION FOR INSTALLATION OF NEW MECHANICAL OR ELECTRICAL 317-634-4672
22 22 WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR TRADE
REQUIRING THE DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, FLOOR
SLAB AND PAVEMENT CUTTING FOR UNDERGROUND PIPING, CORING FOR WALL
AND FLOOR PENETRATIONS, ROOF PENETRATIONS, ETC. REFER TO MECHANICAL
AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION.
22 N. DISCONNECT AND CAP-OFF OR REMOVE OBSOLETE EXISTING UTILITY AND
SERVICE LINES PRIOR TO STARTING DEMOLITION WORK.
23 O. REMOVE ABANDONED UNDERGROUND UTILITIES AND INSTALL ENGINEERED FILL.
P. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE SUSPECTED OR
DISCOVERED TO CONTAIN ASBESTOS OR OTHER HAZARDOUS MATERIALS, STOP
DEMOLITION AND NOTIFY OWNER AND ARCHITECT IMMEDIATELY.
Q. REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP MATERIALS WHERE
DAMAGED DUE TO SELECTIVE DEMOLITION ACTIVITIES TO RESTORE ORIGINAL
FIRE RATING UNLESS OTHERWISE INDICATED.
R. THE FOLLOWING DEMOLITION WORK SHALL BE PERFORMED AS PART OF THE
WORK UNDER THE APPROPRIATE PROJECT MANUAL SECTIONS: A.) REMOVAL OF
EXISTING ROOFING. B.) REMOVAL OF EXISTING WINDOWS, TEMPORARY WINDOW
OPENING CLOSURES AND OPENING PREPARATION TO RECEIVE NEW WINDOW
UNITS.
S. REFER TO WALL SECTIONS NOTED ON DEMOLITION PLANS FOR ADDITIONAL
REMOVE ALL EXISTING DEMOLITION INFORMATION.
ROOF DRAINS TO BE T. REFER TO PROJECT MANUAL DIVISION 4 FOR SPECIAL REQUIREMENTS
REPLACED WITH REGARDING DISPOSAL OF DEMOLISHED MASONRY RUBBLE.
COMBINATION ROOF U. ALL WALL AND FLOOR FINISHES ARE TO REMAIN UNLESS NOTED OTHERWISE.
DRAIN AND OVERFLOW
UNITS TYPICAL REV. 11/08/05

KEYNOTES - DEMOLITION

01 REMOVE EXISTING WALL CONSTRUCTION, DOORS AND FRAMES COMPLETELY.


02 REMOVE EXISTING BRICK WIINDOW FILL IN IT'S ENTIRETY. F
03 DUCTED FUME HOODS TO BE REMOVED BY THE HAZARDOUS MATERIAL ABATEMENT
CONTRACTOR.
3 G

24 24 04 REMOVE EXISTING BUILT-IN EQUIPMENT/CABINETRY IN IT'S ENTIRETY.


E
2
05 REMOVE EXISTING LOOSE EQUIPMENT, MACHINES, FURNITURE AND INSTALLED
MARKERBOARDS STORE AS REQUESTED BY OWNER. D
2 06 EXISTING WOOD FLOORING AND STRUCTURE ABOVE TO REMAIN
07 REMOVE ALL EXISTING MECHANICAL, TIE UP AND SALVAGE LIGHT FIXTURES ONLY C
22 WHERE CEILING GRID REPLACEMENT OCCUR, WHERE CEILING IS TO REMAIN EXPOSED
TO DECK, ASSUME NEW MECHANICAL AND OTHER COMPONENTRY IS TO BE DRYFALL

22 22
PAINTED TO MATCH EXISTING EXPOSED STRUCTURE. WHERE CEILING IS EXPOSED
WOOD TIMBER, COLOR OF DUCTS IS TO BE DETERMINED.
B 1
08 REMOVE EXISTING ACOUSTICAL TILE CEILING AND SUPPORTS IN IT'S ENTIRETY. TIE UP
AND SALVAGE LIGHT FIXTURES AS DESCRIBED IN NOTE 07. ASSUME NEW CEILING A
7
6 GRID AND TILES ARE TO BE INSTALLED AND WILL CONCEAL NEW MECHANICAL
EQUIPMENT..
23
09 REMOVE EXISTING LIGHTING IN THIS SHADED AREA. REFERENCE RCP FOR CEILING IN KEY PLAN
THIS AREA.
10 REMOVE EXISTING FLOORING, BASE AND WALL FINISHES IN THEIR ENTIRETY AND
PREPARE FOR NEW. SEAL | DATE 04/01/21
11 DESIGN INTENT IS TO MAINTAIN VERTICAL FACE AND UNDERSIDE OF BULKHEADS/
DRYWALL CEILINGS WHERE POSSIBLE AND PATCH TO AS-NEW CONDITION IF ANY
WORK ABOVE THE CEILING IS REQUIRED, IN LIEU OF REBUILDING IF ANY LIGHT
FIXTURES EXIST, SALVAGE AND REUSED IN PATCHED CEILING IF POSSIBLE..
12 REMOVE EXISTING DRYWALL CEILING AND SUPPORTS. REFERENCE RCP FOR FINAL
DESIGN INTENT. IF IN EXISTENCE, WALL SCONCES ARE TO REMAIN.. IF CEILING
LIGHTS EXIST, SALVAGE FOR REUSE IN NEW CEILING UNLESS SHOWN OTHERWISE IN
NEW CEILING PLAN..
13 EXISTING TO REMAIN.
14 REMOVE HORIZONTAL PORTION OF HARDLID CEILINGS FOR HVAC WORK. REMOVE
WOOD PANELING IN CEILINGS. EXISTING STEPPED COFFER, DRYWALL WRAPPED
TRUSSES AND VERTICAL PORTIONS OF HARDLID CEILINGS TO REMAIN FOR REUSE.
15 REMOVE EXISTING CERAMIC TILE ON WALLS AND FLOOR IN ITS ENTIRETY.
23 CONFIRM WITH
OWNER WHICH 16 REMOVE EXISTING LEVEL 2 BRIDGE CONSTRUCTION AND RAILING IN ITS ENTIRETY TO SHEET ISSUE
CREATE OPENING TO BELOW
ROOF-MOUNTED 1 Construction Documents 04/01/21
EQUIPMENT AND 17 CAREFULLY SALVAGE ACOUSTICAL PANELS MOUNTED TO WALLS FOR POSSIBLE
24 REUSE BY OWNER. VERIFY RELOCATION DIRECTION WITH OWNER.
MISC. STEEL NEEDS
TO BE REMOVED. 18 WALLS N THIS AREA REPRESENT TEMPORARY OFFICES CREATED IN INTIAL PHASE OF
CONSTRUCTION. THESE ARE TO BE REMOVED, ALONG WITH CEILINGS AND FINISHES
AT CORRECT PHASE TO CONVERT THESE ROOMS TO CLASSROOMS. EXISTING
CEILINGS CAN REMAIN AND LIGHTING RECONFIGURED DURING TEMPORARY OFFICE
PHASE AND ALL IS TO BE REMOVED FOR FINAL CLASSROOM PHASE.
22 19 REMOVE EXISTING GLAZING AND FRAMING AS REQUIRED TO ACCEPT NEW
MECHANICAL LOUVER.
20 REMOVE EXISTING WINDOWS AND FRAMES IN THEIR ENTIRETY.
4 22
21 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL.
22 REMOVE EXISTING SKYLIGHT FRAME, GLAZING, AND ACCESSORIES DOWN TO EXISTING
CURB IN ENTIRETY.
24 5
23 REMOVE EXISTING ROOF DUCT CHASE, FRAMING, AND ROOFING IN ENTIRETY.
24 REMOVE EXISTING ROOFING, INSULATION, AND CRICKET MATERIAL IN ENTIRETY TO
RECEIVE NEW ROOF AND FLASHINGS.
25 REMOVE EXISTING METAL LADDER, PLATFORM, AND SUPPORTS COMPLETE.
26 REMOVE EXISTING DOOR PANEL AND HARDWARE AT TOP OF PLATFORM, FRAME TO
REMAIN.
27 REMOVE EXISTING CONCRETE HOUSEKEEPING PAD FLUSH TO SURROUNDING FLOOR
ELEVATION TO RECEIVE NEW HOUSEKEEPING PAD.
29 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF ACADEMIC
BUILDING CONSTRUCTION. EXISTING TO REMAIN WITHOUT DISRUPTION IF POSSIBLE.
IF NOT POSSIBLE, ASSUME NARRATIVE FROM 07 AND 08 TO BE APPLIED TO THIS AREA.
30 ALTERNATE BID # A-2: REPLACE EXISTING LINEAR PENDANT WITH NEW SPECIALTY
LIGHTING FOR LIVING WALL PER ELECTRICAL LIGHTING PLANS
31 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF 2020
SUMMER CONSTRUCTION. AS MUCH OF EXISTING CENTER PORTION TO REMAIN
WITHOUT DISRUPTION IF POSSIBLE.
33 REMOVE EXISTING SKYLIGHT AND LIGHTING. REFERENCE ARCHITECTURAL AND
DETAILED SECTIONS FOR ARCHITECTURAL DESIGN INTENT TO DETERMINE EXTENT OF
DEMOLITION. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
34 FLOORING TO REMAIN AT STAIRS. REMOVE EXISTING DISPLAY PILASTERS UNDER AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
STAIRS. COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
35 REMOVE ALL EXISTING CEILING, LIGHTING, REMAINING WALL FINISHES AND FLOOR
FINISHES. PREP AREA FOR NEW CEILING, FINISHES, HVAC AND FLOOR PLAN LAYOUT PROJECT NO. 19010.000
AS NEEDED.
36 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH SHEET TITLE
STRUCTURAL. REMOVE EXSTING LIGHTING IN THIS AREA.
37 INVESTIGATE CONSTRUCTION OF THIS HORIZONTAL BEAM TO DETERMINE FEASIBILITY ROOF DEMOLITION
OF REMOVING BOTTOM FURRING STRIPS AND RECONSTRUCTION TO MATCH HEIGHT
OF HORIZONTAL BEAM TO
38 PROVIDE ALT. BID NO A-5 TO REMOVE EXISITNG QUARRY TILE ON STAIRS AND
PLAN
PREPARE FOR NEW TREADS, RISERS, LANDING AND STRINGERS AS REQUIRED PER
4/1/2021 11:29:38 AM

THE FINISH PLANS. THIS INCLUDES REMOVAL OF PEDESTALS ON LEVEL 1.


39 REMOVE ROOFING, INSULATION, AND STRUCTURE AS REQUIRED FOR NEW ROOF
HATCH.
40 SELECTIVELY DEMO AS REQUIRED FOR HVAC WORK. IF FLOORING ABOVE IS
A5 ROOF DEMOLITION PLAN AFFECTED, CAREFULLY SALVAGE FLOORING FOR REINSTALLATION AFTER HVAC WORK
IS COMPLETE.
SHEET NUMBER
AD-115
1/16" = 1'-0" 41 SELECTIVELY DEMO BEHIND COLUMNS TO ALLOW FOR FULL PENETRATION WELDING
OF COLUMN STUBS. AD-115
KEYNOTES - DEMOLITION

01 REMOVE EXISTING WALL CONSTRUCTION, DOORS AND FRAMES COMPLETELY.


RHIT MOENCH
02 REMOVE EXISTING BRICK WIINDOW FILL IN IT'S ENTIRETY.
03 DUCTED FUME HOODS TO BE REMOVED BY THE HAZARDOUS MATERIAL ABATEMENT
CONTRACTOR.
RENOVATION
04 REMOVE EXISTING BUILT-IN EQUIPMENT/CABINETRY IN IT'S ENTIRETY.
05 REMOVE EXISTING LOOSE EQUIPMENT, MACHINES, FURNITURE AND INSTALLED
5500 Wabash Avenue
MARKERBOARDS STORE AS REQUESTED BY OWNER.
06 EXISTING WOOD FLOORING AND STRUCTURE ABOVE TO REMAIN
Terre Haute, Indiana
07 REMOVE ALL EXISTING MECHANICAL, TIE UP AND SALVAGE LIGHT FIXTURES ONLY
WHERE CEILING GRID REPLACEMENT OCCUR, WHERE CEILING IS TO REMAIN EXPOSED
TO DECK, ASSUME NEW MECHANICAL AND OTHER COMPONENTRY IS TO BE DRYFALL
47803
PAINTED TO MATCH EXISTING EXPOSED STRUCTURE. WHERE CEILING IS EXPOSED Owner
WOOD TIMBER, COLOR OF DUCTS IS TO BE DETERMINED.
08 REMOVE EXISTING ACOUSTICAL TILE CEILING AND SUPPORTS IN IT'S ENTIRETY. TIE UP Rose-Hulman Institute of Technology
AND SALVAGE LIGHT FIXTURES AS DESCRIBED IN NOTE 07. ASSUME NEW CEILING 5500 Wabash Avenue
GRID AND TILES ARE TO BE INSTALLED AND WILL CONCEAL NEW MECHANICAL Terre Haute, Indiana 47803
EQUIPMENT.. 812-877-1511
09 REMOVE EXISTING LIGHTING IN THIS SHADED AREA. REFERENCE RCP FOR CEILING IN
THIS AREA.
10 REMOVE EXISTING FLOORING, BASE AND WALL FINISHES IN THEIR ENTIRETY AND
PREPARE FOR NEW.
11 DESIGN INTENT IS TO MAINTAIN VERTICAL FACE AND UNDERSIDE OF BULKHEADS/
DRYWALL CEILINGS WHERE POSSIBLE AND PATCH TO AS-NEW CONDITION IF ANY
WORK ABOVE THE CEILING IS REQUIRED, IN LIEU OF REBUILDING IF ANY LIGHT
FIXTURES EXIST, SALVAGE AND REUSED IN PATCHED CEILING IF POSSIBLE..
12 REMOVE EXISTING DRYWALL CEILING AND SUPPORTS. REFERENCE RCP FOR FINAL
DESIGN INTENT. IF IN EXISTENCE, WALL SCONCES ARE TO REMAIN.. IF CEILING
LIGHTS EXIST, SALVAGE FOR REUSE IN NEW CEILING UNLESS SHOWN OTHERWISE IN
NEW CEILING PLAN.. Architect
E D C B A
A B C D 13 EXISTING TO REMAIN. RATIO
14 REMOVE HORIZONTAL PORTION OF HARDLID CEILINGS FOR HVAC WORK. REMOVE 101 South Pennsylvania Street
WOOD PANELING IN CEILINGS. EXISTING STEPPED COFFER, DRYWALL WRAPPED Indianapolis, Indiana 46204
T/O NORTH GABLE T/O NORTH GABLE TRUSSES AND VERTICAL PORTIONS OF HARDLID CEILINGS TO REMAIN FOR REUSE. 317-633-4040
163'-5 13/16" 163'-5 13/16" 15 REMOVE EXISTING CERAMIC TILE ON WALLS AND FLOOR IN ITS ENTIRETY.
16 REMOVE EXISTING LEVEL 2 BRIDGE CONSTRUCTION AND RAILING IN ITS ENTIRETY TO
CREATE OPENING TO BELOW Structural Engineer
17 CAREFULLY SALVAGE ACOUSTICAL PANELS MOUNTED TO WALLS FOR POSSIBLE
REUSE BY OWNER. VERIFY RELOCATION DIRECTION WITH OWNER.
Fink Roberts & Petrie, Inc.
18 WALLS N THIS AREA REPRESENT TEMPORARY OFFICES CREATED IN INTIAL PHASE OF 9449 Priority Way W Dr #200
CONSTRUCTION. THESE ARE TO BE REMOVED, ALONG WITH CEILINGS AND FINISHES Indianapolis, Indiana 46240
AT CORRECT PHASE TO CONVERT THESE ROOMS TO CLASSROOMS. EXISTING 317-872-8400
CEILINGS CAN REMAIN AND LIGHTING RECONFIGURED DURING TEMPORARY OFFICE
PHASE AND ALL IS TO BE REMOVED FOR FINAL CLASSROOM PHASE.
19 REMOVE EXISTING GLAZING AND FRAMING AS REQUIRED TO ACCEPT NEW
MECHANICAL LOUVER.
Mechanical / Electrical Engineer
20 REMOVE EXISTING WINDOWS AND FRAMES IN THEIR ENTIRETY. R.E. Dimond & Associates, Inc.
21 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH 732 N Capitol Avenue
STRUCTURAL. Indianapolis, Indiana 46204
T/O PARAPET T/O PARAPET 22 REMOVE EXISTING SKYLIGHT FRAME, GLAZING, AND ACCESSORIES DOWN TO EXISTING 317-634-4672
142'-8" 142'-8" CURB IN ENTIRETY.
23 REMOVE EXISTING ROOF DUCT CHASE, FRAMING, AND ROOFING IN ENTIRETY.
24 REMOVE EXISTING ROOFING, INSULATION, AND CRICKET MATERIAL IN ENTIRETY TO
RECEIVE NEW ROOF AND FLASHINGS.
25 REMOVE EXISTING METAL LADDER, PLATFORM, AND SUPPORTS COMPLETE.
26 REMOVE EXISTING DOOR PANEL AND HARDWARE AT TOP OF PLATFORM, FRAME TO
N SECOND LEVEL N SECOND LEVEL REMAIN.
133'-6 13/16" 133'-6 13/16"
27 REMOVE EXISTING CONCRETE HOUSEKEEPING PAD FLUSH TO SURROUNDING FLOOR
ELEVATION TO RECEIVE NEW HOUSEKEEPING PAD.
29 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF ACADEMIC
02 02 02 02 BUILDING CONSTRUCTION. EXISTING TO REMAIN WITHOUT DISRUPTION IF POSSIBLE.
IF NOT POSSIBLE, ASSUME NARRATIVE FROM 07 AND 08 TO BE APPLIED TO THIS AREA.
30 ALTERNATE BID # A-2: REPLACE EXISTING LINEAR PENDANT WITH NEW SPECIALTY
LIGHTING FOR LIVING WALL PER ELECTRICAL LIGHTING PLANS
31 EXISTING CEILING AND LIGHTING ARE NEWLY CONSTRUCTED AT TIME OF 2020
FIRST LEVEL FIRST LEVEL SUMMER CONSTRUCTION. AS MUCH OF EXISTING CENTER PORTION TO REMAIN
120'-11 13/16" 120'-11 13/16" WITHOUT DISRUPTION IF POSSIBLE.
33 REMOVE EXISTING SKYLIGHT AND LIGHTING. REFERENCE ARCHITECTURAL AND
DETAILED SECTIONS FOR ARCHITECTURAL DESIGN INTENT TO DETERMINE EXTENT OF
DEMOLITION.
20
34 FLOORING TO REMAIN AT STAIRS. REMOVE EXISTING DISPLAY PILASTERS UNDER
02 STAIRS.
20 02 35 REMOVE ALL EXISTING CEILING, LIGHTING, REMAINING WALL FINISHES AND FLOOR
LOWER LEVEL LOWER LEVEL FINISHES. PREP AREA FOR NEW CEILING, FINISHES, HVAC AND FLOOR PLAN LAYOUT
110'-7 1/16" 110'-7 1/16" AS NEEDED.
36 REMOVE SECTION OF EXISTING WOOD FLOOR AND STRUCTURE-COORDINATE WITH
STRUCTURAL. REMOVE EXSTING LIGHTING IN THIS AREA.
37 INVESTIGATE CONSTRUCTION OF THIS HORIZONTAL BEAM TO DETERMINE FEASIBILITY
OF REMOVING BOTTOM FURRING STRIPS AND RECONSTRUCTION TO MATCH HEIGHT
OF HORIZONTAL BEAM TO
38 PROVIDE ALT. BID NO A-5 TO REMOVE EXISITNG QUARRY TILE ON STAIRS AND
PREPARE FOR NEW TREADS, RISERS, LANDING AND STRINGERS AS REQUIRED PER
LOWER LEVEL 2 LOWER LEVEL 2 THE FINISH PLANS. THIS INCLUDES REMOVAL OF PEDESTALS ON LEVEL 1.
100'-0" 100'-0"
39 REMOVE ROOFING, INSULATION, AND STRUCTURE AS REQUIRED FOR NEW ROOF
HATCH.
40 SELECTIVELY DEMO AS REQUIRED FOR HVAC WORK. IF FLOORING ABOVE IS
AFFECTED, CAREFULLY SALVAGE FLOORING FOR REINSTALLATION AFTER HVAC WORK
IS COMPLETE.
41 SELECTIVELY DEMO BEHIND COLUMNS TO ALLOW FOR FULL PENETRATION WELDING
C3 EAST DEMO ELEVATION C6 WEST DEMO ELEVATION OF COLUMN STUBS.
AD-201 AD-201
1/8" = 1'-0" 1/8" = 1'-0"

N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 SEAL | DATE 04/01/21

T/O NORTH GABLE


163'-5 13/16"

SHEET ISSUE
1 Construction Documents 04/01/21

T/O PARAPET
142'-8"

N SECOND LEVEL
133'-6 13/16"

20 20 20 20
02 02 02 02 02 02 02 02 02

FIRST LEVEL
120'-11 13/16"

19 20 02 20 02 20 02
20 02 20 02
LOWER LEVEL
110'-7 1/16"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

LOWER LEVEL 2 PROJECT NO. 19010.000


100'-0"
SHEET TITLE

EXTERIOR DEMO
ELEVATIONS
A3 NORTH DEMO ELEVATION
4/1/2021 11:29:44 AM

AD-201
1/8" = 1'-0"

SHEET NUMBER

AD-201
KEYNOTE LEGEND
RHIT MOENCH
RENOVATION
N10 N9 N8 N7 N6 N5 A-201 N4 N3 N2 N1 5500 Wabash Avenue
AREA 3 AREA 2 A3
Terre Haute, Indiana
A 47803
Owner
Rose-Hulman Institute of Technology
SERVER 5500 Wabash Avenue
OFFICE RECEIVING ROOM
G138 G134
Terre Haute, Indiana 47803
G110 MECHANICAL B 812-877-1511
268 SF 372 SF
TECH SHOP 509 SF
ROOM C3 A-201
G130 G106 STORAGE
A-201 C6 ELECTRICAL
730 SF 666 SF FL206
2872 SF SWITCH GEAR MECHANICAL
STORAGE OFFICE OFFICE FL203 FL201
G100B OFFICE
G136 G132 WORK AREA 282 SF 2933 SF
27 SF 142 SF 146 SF G100A G108
79 SF
189 SF C
CIRCULATION CIRCULATION RESTROOM MECHANICAL
G100 G111 G101
OFFICE 1227 SF FL202
OFFICE OFFICE 153 SF 61 SF 316 SF
G153 G151 G133 OFFICE Architect
119 SF 92 SF 93 SF G131 OFFICE OFFICEBREAK AREA RATIO
173 SF
G123 G113 G103A MAIL DIST.
OFFICE OFFICE OFFICE 106 SF 105 SF 58 SF
D CENTER 101 South Pennsylvania Street
G149 G147 G137 ANNEX Indianapolis, Indiana 46204
116 SF 93 SF 93 SF OFFICE OFFICE OFFICE 317-633-4040
EL204
G135 G121 G115 CONFERENCE DELIVERY 82 SF
144 SF 107 SF 105 SF CAGE
OFFICE ROOM DELIVERY
OFFICE G103 STORAGE - ELEV 1 CAGE
OFFICE G143 255 SF G105 129 SF - Structural Engineer
101 SF G141 OFFICE OFFICE OFFICE -
G145 145 SF
204 SF 84 SF 129 SF Fink Roberts & Petrie, Inc.
180 SF G139 G119 G117 E
184 SF 162 SF 159 SF ELEVATOR
OFFICE 9449 Priority Way W Dr #200
MECHANICAL FAB. LAB
EL202A
EL203
Indianapolis, Indiana 46240
120 SF STOCK
88 SF STORAGE 317-872-8400
AREA 3 AREA 2
CL208
215 SF

MACHINE Mechanical / Electrical Engineer


F
TOOL LAB II FABRICATION
EL202 LAB R.E. Dimond & Associates, Inc.
STAIR CIRCULATION 826 SF TOOL ROOM EL207 732 N Capitol Avenue
EL211 957 SF
A5 - EL205 Indianapolis, Indiana 46204
211 SF 175 SF
A-301 119 SF 317-634-4672

G
INSTRUCTIONAL
TECHNOLOGY
DL204 MACHINE
248 SF TOOL SHOP
DL202
1058 SF

H
I.T.
MENS R.R. EQUIP./OFFICE
DL203 DL204A
151 SF
415 SF

C2
J A-301

OFFICE
MANAGER
DL205
OFFICE 134 SF
DL204B
60 SF WORK SHOP OFFICE
DL206A DL206 MANUFACTURING
129 SF 97 SF
K LAB
DL201
1101 SF

AREA 2 ROBOTICS AREA 2


CLASSROOM
L DL207 AREA 1
AREA 1 825 SF
F
3 G

ROBOTICS MATERIALS
E
2
M WORKROOM/STORAGE LAB D
DL207A CL207
197 SF 1076 SF

A2 STAIR C
A-301 CL211

STORAGE
133 SF
B 1
N CL202B
120 SF CUSTODIAL A
CUSTODIAL
STORAGE
SERVICES
CL212
CL202
436 SF
41 SF DN KEY PLAN

O SEAL | DATE 04/01/21

CUSTODIAL OFFICE INSTRUMENT WORK SHOP


STORAGE CL203 STORAGE CL206
177 SF 258 SF
CL202A CL205
454 SF 246 SF

5.9 5.5 5.1 4.1 3.1 2.1 1.2 SHEET ISSUE


1 Construction Documents 04/01/21

B5 LOWER LEVEL 2 OVERALL PLAN


A-101
1/16" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

LOWER LEVEL 2
OVERALL FLOOR
PLAN
4/1/2021 11:41:34 AM

SHEET NUMBER

A-101
KEYNOTE LEGEND RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
DL201A Rose-Hulman Institute of Technology
AREA 2 5500 Wabash Avenue
AREA 2 Terre Haute, Indiana 47803
ROBOTICS 812-877-1511
CLASSROOM
L DL207 CL207C
AREA 1
AREA 1 825 SF

CL207B

Architect
RATIO
MATERIALS 101 South Pennsylvania Street
ROBOTICS LAB Indianapolis, Indiana 46204
M CL207
WORKROOM/STORAGE 317-633-4040
1076 SF
DL207A
197 SF
Structural Engineer
Fink Roberts & Petrie, Inc.
A2 STAIR CL207A 9449 Priority Way W Dr #200
A-301 CL211 Indianapolis, Indiana 46240
133 SF
CUSTODIAL 317-872-8400
STORAGE
CL212
CL202B 41 SF
Mechanical / Electrical Engineer
STORAGE R.E. Dimond & Associates, Inc.
CL212
N CL202B
120 SF 732 N Capitol Avenue
Indianapolis, Indiana 46204
CL202 317-634-4672
CUSTODIAL
SERVICES
CL202
436 SF CIRCULATION
-
DN

CL205

OFFICE WORK SHOP


CUSTODIAL CL203 INSTRUMENT CL206
177 SF 258 SF
STORAGE STORAGE
CL202A CL205
454 SF 246 SF

5.9 5.5 5.1 4.1 3.1 2.1 1.2 F


3 G
E
2
D

B 1
A

KEY PLAN

SEAL | DATE 04/01/21

C4 LOWER LEVEL 2 PLAN


A-101.1
1/8" = 1'-0"

SHEET ISSUE
1 Construction Documents 04/01/21

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

LOWER LEVEL 2
FLOOR PLAN - AREA
1
4/1/2021 11:41:37 AM

SHEET NUMBER

A-101.1
KEYNOTE LEGEND
N10 N9 N8 N7 N6 N5 A-201
N4 N3 N2 N1
RHIT MOENCH
A3 RENOVATION
AREA 2 5500 Wabash Avenue
A
FL206E
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

STORAGE
STORAGE FL205
FL206
2872 SF
ELECTRICAL Architect
SWITCH GEAR
FL203
MECHANICAL RATIO
282 SF FL201 101 South Pennsylvania Street
2933 SF
Indianapolis, Indiana 46204
317-633-4040
FL202

C Structural Engineer
FL203 Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
MECHANICAL 317-872-8400
FL202
316 SF

FL205
Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
FL201
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672
D

EL203 EL204

ELEVATOR MAIL DIST.


DELIVERY
ELEV 1 MECHANICAL CENTER
CAGE
- EL203 ANNEX
84 SF -
DELIVERY 88 SF EL204 129 SF
82 SF
CAGE
E - EL207A
129 SF

FAB. LAB
OFFICE STOCK
EL202A STORAGE
120 SF CL208
215 SF

AREA 2
EL211B
F
MACHINE
TOOL LAB II
EL202 FABRICATION
F
826 SF LAB
EL207
957 SF
3 G
CIRCULATION
STAIR
-
EL211
211 SF
TOOL ROOM
EL205
175 SF
E
2
A5 119 SF
A-301 D

G
EL211A
B 1
DL202B
A
INSTRUCTIONAL
TECHNOLOGY DL202A
DL204 KEY PLAN
248 SF

MACHINE
TOOL SHOP
SEAL | DATE 04/01/21
DL202
1058 SF

MENS R.R. I.T.


DL203 EQUIP./OFFICE
151 SF DL204A
415 SF

SHEET ISSUE
1 Construction Documents 04/01/21

C2
A-301
J DL201B

MANAGER
OFFICE OFFICE
DL204B DL205
60 SF 134 SF

WORK SHOP OFFICE


DL206A DL206
129 SF 97 SF

MANUFACTURING
K LAB
DL201
1101 SF

DL201A
AREA 2
AREA 2
ROBOTICS
CLASSROOM
L DL207 CL207C
AREA 1
AREA 1 825 SF
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
CL207B AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


5.9 5.5 5.1 4.1 3.1 2.1 1.2 SHEET TITLE

LOWER LEVEL 2
A3 LOWER LEVEL 2 PLAN
FLOOR PLAN - AREA
A-101.2
1/8" = 1'-0" 2
4/1/2021 11:41:41 AM

SHEET NUMBER

A-101.2
KEYNOTE LEGEND
RHIT MOENCH
AREA 3 AREA 2 RENOVATION
N10 N9 N8 N7 N6 N5 A-201 N4 N3 N2 N1
5500 Wabash Avenue
A3 Terre Haute, Indiana
A
DEPT.
47803
HEAD FACULTYFACULTYFACULTYFACULTYFACULTYFACULTYFACULTYFACULTY
FL116B OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE Owner
CLOSET FL115 FL113 FL111 FL109 FL107 FL105 FL103 FL101
G220A Rose-Hulman Institute of Technology
32 SF MENS R.R.
G206
5500 Wabash Avenue
165 SF STUDY AREA B ADMIN Terre Haute, Indiana 47803
C3 A-201 812-877-1511
CLASSROOM CLASSROOM G204 OFFICE
CLASSROOM 299 SF A-201 FL116
G222 G203 C6
938 SF G220 FACULTY
733 SF
FACULTYFACULTYFACULTY
WOMENS R.R. FACULTY OFFICE FACULTY
OFFICE OFFICE OFFICE
G202 OFFICE COLLISION
110 SF
C FL114
FL112
FL108
FL106 FL104 FL102

14

Architect
STG. RATIO
G210A D
KITCHEN
101 South Pennsylvania Street
CAFE Indianapolis, Indiana 46204
EL127 EL125
CLASSROOM CLASSROOM CLASSROOM 278 SF 317-633-4040

DW
HOUSEKEEPING
G221 G219 G208
858 SF 852 SF STUDENT ELEV 1 EQUIPMENT
AREA - ROOM
G210 84 SF EL102 Structural Engineer
E 184 SF
Fink Roberts & Petrie, Inc.
STORAGE MAIL SORT 9449 Priority Way W Dr #200
EL126 CORRIDOR EL103
-- Indianapolis, Indiana 46240
93 SF 466 SF
COOK 317-872-8400
LOUNGE
GREENHOUSE
EL112
G219A 2409 SF
1266 SF
F Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
WOMENS R.R. MENS R.R. 732 N Capitol Avenue
A5
A-301
EL105 EL104 Indianapolis, Indiana 46204
225 SF 256 SF
317-634-4672
G
SEMICONDUCTOR
OFFICE OFFICE OFFICE OFFICE OPTICS LAB
AREA 3 AREA 2 OFFICE DL110D DL110E DL110F DL110G DL108
DL110C 228 SF
OFFICE
DL107
217 SF

H
OFFICE
DL110B OFFICEADMIN OFFICE NUCLEAR
DL110A DL110 PHYSICS LAB OFFICE
DL105 DL106
230 SF
OPTICAL 253 SF

J ENGINEERING
LAB 3 OPTICAL
DL115 OFFICE METROLOGY
OFFICE
1095 SF DL116 LAB
DL120 OFFICE
DL104 DL103
255 SF
230 SF
ELECTRICAL
EQUIPMENT
K ROOM
DL118
OPTICAL
ENGINEERING SENIOR OFFICE
LAB 1 DARK ROOM DESIGN LAB
AREA 2 G112 DL102 AREA 2
DL117 195 SF
DL101 230 SF
544 SF 253 SF
CLASSROOM
L
DL119 ACOUSTICS
AREA 1 AREA 1
OPTICAL 384 SF PROJECTS
ENGINEERING LAB OFFICE F
LAB 2
CL118
CL110
223 SF
CL109
230 SF
3 G

M
748 SF E
2
M.T.F. D
MEASUREMENT NON-LINEAR CONFERENCE
A2 LAB OPTICS LAB ROOM H BAR
A-301 CL114 CL115 CL116 EL108 C
182 SF 346 SF 289 SF 183 SF

N
B 1
A
OFFICE ADMIN OFFICE OFFICE
OFFICE CL108 CL106 CL105
CL107 207 SF 266 SF 288 SF
213 SF
KEY PLAN
PHYSICS LAB
O 3 E.I.T.
CL117 CL102A SEAL | DATE 04/01/21
1712 SF CLASSROOM 48 SF
CL119 OPTICAL
ELECTRICAL OFFICE
454 SF COMMUNICATIONS
ROOM CL104
STORAGE LAB
CL101 184 SF
81 SF CL102B CL103
107 SF 218 SF
P
ENGINEERING
PHYSICS LAB OFFICE
1 BL103 OFFICE
MATERIALS BL110 158 SF BL102
604 SF 191 SF
PROCESSING
PHYSICS LAB LAB
BL112 OFFICE
Q 1
BL113 509 SF BL104
163 SF
1672 SF
PHYSICS
SHEET ISSUE
STOCK ROOM OFFICE OFFICE 1 Construction Documents 04/01/21
BL108 BL109 OFFICE BL101
385 SF 231 SF 171 SF
BL105
163 SF
R

MACHINE
ELECTRICAL SHOP OFFICE OFFICE
ROOM BL107 BL106 BL100
706 SF 182 SF 193 SF
PHYSICS LAB BL115
195 SF
S 2
BL114 ELEV 2
1652 SF
CUSTODIAL -
STORAGE 45 SF
BL116
159 SF OFFICE OFFICE OFFICE
9.8 8.9 6.9 5.9 5.5
AL104 5.1 AL103 4.1AL102 3.1 2.1 1.2
112 SF
111 SF 109 SF
T
ELEVATOR
STORAGE
MECHANICAL
ART CURATOR AL101A
BL117 215 SF
32 SF AL101
341 SF

7.9
U
WATER ROOM
AL106
50 SF

V
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000

W SHEET TITLE
C2
A-301
LOWER LEVEL 1
OVERALL FLOOR
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
PLAN
4/1/2021 11:41:52 AM

A5 LOWER LEVEL 1 OVERALL PLAN SHEET NUMBER


A-102
1/16" = 1'-0"

A-102
OPTICAL
ENGINEERING SENIOR OFFICE
DARK ROOM
LAB 1 DESIGN LAB DL102
G112 230 SF
DL117 195 SF DL101
AREA 2 544 SF 253 SF AREA 2
KEYNOTE LEGEND RHIT MOENCH
L
DL117B
CLASSROOM
DL119
384 SF
RENOVATION
HOLOGRAPHIC ACOUSTICS
5500 Wabash Avenue
OPTICAL PROJECTS OFFICE
ENGINEERING
LAB 2
INTERFEROMETRY
LAB
S3C
LAB
CL110
CL109
230 SF
Terre Haute, Indiana
CL112
CL118
748 SF
223 SF
47803
CL110 Owner
CL112A
CL112 Rose-Hulman Institute of Technology
CL109
5500 Wabash Avenue
M CL114 Terre Haute, Indiana 47803
812-877-1511

M.T.F.
MEASUREMENT NON-LINEAR CONFERENCE
A2 LAB OPTICS LAB ROOM CIRCULATION STAIR H BAR
A-301 CL114 CL115 CL116 - - EL108
4200 SF 107 SF 183 SF
182 SF 346 SF 289 SF

Architect
N RATIO
101 South Pennsylvania Street
CL105B Indianapolis, Indiana 46204
CL117 317-633-4040

OFFICE ADMIN OFFICE OFFICE Structural Engineer


CL108 CL106 CL105
OFFICE 207 SF 266 SF 288 SF Fink Roberts & Petrie, Inc.
CL107 9449 Priority Way W Dr #200
213 SF Indianapolis, Indiana 46240
317-872-8400
CL106 CL105A
O PHYSICS LAB
3 Mechanical / Electrical Engineer
CL117 CL104
1712 SF
2'-0" CIRCULATION R.E. Dimond & Associates, Inc.
S3A - 732 N Capitol Avenue
CLASSROOM 718 SF
CL119 Indianapolis, Indiana 46204
CL101 CL103
454 SF S3A 317-634-4672
FIRE RISER OFFICE
OPTICAL
CLOSET CL104
COMMUNICATIONS 184 SF
CL101A ELECTRICAL LAB
E.I.T. STORAGE
CL119 ROOM CL103
CL102A CL102B
CL101A CL101 48 SF 107 SF 218 SF
81 SF
S3C

ENGINEERING OFFICE
PHYSICS LAB BL103
1 158 SF OFFICE
BL110 BL102
604 SF BL103 191 SF

BL110
MATERIALS
PROCESSING BL104
LAB
BL102
PHYSICS LAB BL112 OFFICE
Q 1 509 SF
BL104
BL113 163 SF
1672 SF BL101

PHYSICS
BL112 BL105
STOCK ROOM OFFICE OFFICE
BL108 BL109 BL101
385 SF 231 SF 171 SF
OFFICE
BL105 F
BL113
BL108
163 SF
3 G

R X
BL100A
E
2
BL100
D
BL106
BL114
C

BL107 MACHINE
SHOP OFFICE OFFICE
B 1
ELECTRICAL BL107 BL106 BL100
706 SF 182 SF 193 SF A
ROOM
BL115
195 SF
BL115 KEY PLAN
PHYSICS LAB
S 2
BL114 SEAL | DATE 04/01/21
1652 SF
CIRCULATION
ELEV 2
-
- 1018 SF
45 SF
CUSTODIAL
STORAGE
BL116
159 SF
OFFICE
9.8 8.9 6.9 5.9 5.5OFFICE 5.1 AL103 4.1 OFFICE 3.1 2.1 1.2
AL104 112 SF AL102
BL117 111 SF 109 SF

AL101
T
ELEVATOR
MECHANICAL SHEET ISSUE
BL117 STORAGE 1 Construction Documents 04/01/21
32 SF AL101A
XAL101A 215 SF
ART CURATOR
AL101
341 SF
AL106

WATER ROOM
7.9 AL106
50 SF

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE
W
LOWER LEVEL 1
C2
FLOOR PLAN - AREA
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
A-301
1
4/1/2021 11:41:58 AM

A3 LOWER LEVEL 1 PLAN SHEET NUMBER


A-102.1
1/8" = 1'-0"

A-102.1
RHIT MOENCH
KEYNOTE LEGEND
RENOVATION
00-A1
00-A2
CENTER WALL ON COLUMN GRID LINE
CENTER WALL ON MULLION CENTER LINE
5500 Wabash Avenue
A-201
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 097553.A01
105500.16
VEGETATIVE WALL SYSTEM
PRIVATE DELIVERY POSTAL SPECIALTIES
Terre Haute, Indiana
A3
47803
AREA 2 TYP.
A3 TYP. A5 C5 A3 A3 A3 Owner
EW01 EW01 A-622 A-622A-622 EW01 A-622 EW01 A-622 EW01 A-622
Rose-Hulman Institute of Technology
A 5500 Wabash Avenue
Terre Haute, Indiana 47803
00-A2 00-A2 00-A2 00-A2 812-877-1511
COMMUNICATIONS
A-502 B1
CABLE
FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY
DEPT. HEAD OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
EW01
FL116B FL115 FL113 FL111 FL109 FL107 FL105 FL103 FL101
136 SF 136 SF 136 SF 137 SF 137 SF 136 SF 136 SF 128 SF

A-502 B1 B1 A-502 A-502 B1 B1 A-502 A-502 B1 B1 A-502 A-502 B1 B1 A-502

O.H. O.H. O.H. O.H.


FL116B
00-A1
FL115 FL113 FL111 FL109 FL107 FL105 FL103 FL101 Architect
B 00-A1 00-A1 00-A1
A5 A5 RATIO

4'-6 1/2"
ADMIN OFFICE A-532 A5 A-201
C3

ALIGN
A-532
A-532 A5 101 South Pennsylvania Street
FL116 A-532
A3 A-502 O.H. Indianapolis, Indiana 46204

ALIGN
A-622 FL112 FL108 FL106 FL104 FL102 317-633-4040
FL116
00-A2 B1
EW01
B1 FACULTY FACULTY FACULTY FACULTY FACULTY Structural Engineer
FACULTY FL114 OFFICE COLLISION OFFICE OFFICE OFFICE Fink Roberts & Petrie, Inc.
OFFICE FL112 FL108 FL106 FL104 FL102
FL114 A-502 131 SF 270 SF 131 SF 132 SF 131 SF 9449 Priority Way W Dr #200
140 SF Indianapolis, Indiana 46240
C A-501 A7 A7 A7 A7 A-501 317-872-8400
A-501 A-501
A5
A-532 O.H. S3A O.H.

1'-5 7/8"
00-A1 A5
00-A1 Mechanical / Electrical Engineer
A-532
S3A.C
D6 R.E. Dimond & Associates, Inc.
A-422 732 N Capitol Avenue
B2 S3C.C Indianapolis, Indiana 46204
105500.16
2'-0" CLEAR E1 317-634-4672

9'-10 5/8"
CORRIDOR
A-401 A-501
FL120

1'-5 3/8"
1686 SF
3'-2 7/8"
105500.16 A1
S3A.C S3C.C
3/4"
FL120A
4'-0 3/8" FL120B
D

EL127
KITCHEN EL125 CORRIDOR
EL125 -
278 SF 261 SF

EL102

DW
CAFE HOUSEKEEPING
EL127 EQUIPMENT
ELEV 1 S3C ROOM
EL126
MOENCH - EL102
CAFE EL128 STORAGE 84 SF 184 SF

ELXXX EL126
93 SF
E
S3A.C 2'-0" S3C.D S3C.C
S3C.C
C1 B3 A-501 D4 MAIL SORT
F2 EL103 EL103
A-402 466 SF 1'-0"
A-402 D5

A-403 C1 LOUNGE
EL112 S3C.C S3C.C
S3A.C
2409 SF F
S1FA.D.A A3 A-402
EL104
3 G

F
A7
A-532
S7FA A7
A-532
E
2
2'-6" D
S3C.C

A5
AREA 2 WOMENS R.R.
EL105
MENS R.R.
EL104
B 1
A-301 225 SF 256 SF
E1
A-404
A
097553.A01

EL112 KEY PLAN


G
SEAL | DATE 04/01/21

SEMICONDUCTOR
OFFICE OPTICS LAB
OFFICE OFFICE DL108
DL110D OFFICE DL110F DL110G 228 SF
OFFICE DL110E
OFFICE
DL110C DL107
217 SF
DL108

DL107

DL106 SHEET ISSUE


OFFICE DL105 1 Construction Documents 04/01/21
DL110B
OFFICE ADMIN OFFICE
DL110A DL110
NUCLEAR OFFICE
PHYSICS LAB DL106
DL105 230 SF
253 SF

J
OPTICAL
ENGINEERING
LAB 3 OFFICE ELECTRICAL OPTICAL
DL115 DL116 EQUIPMENT OFFICE METROLOGY
1095 SF ROOM DL120 LAB
DL118 DL104 OFFICE
255 SF DL103
230 SF

DL104
DL120
DL115 DL103

DL117A DL102

DL119 DL101

OPTICAL
ENGINEERING SENIOR OFFICE
DARK ROOM
LAB 1 DESIGN LAB DL102
G112 230 SF
DL101 COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
DL117 195 SF
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
AREA 2 544 SF 253 SF AREA 2 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


L CLASSROOM
DL117B DL119 SHEET TITLE
384 SF

HOLOGRAPHIC ACOUSTICS
LOWER LEVEL 1
OPTICAL
ENGINEERING
LAB 2
INTERFEROMETRY
LAB
S3C
PROJECTS
LAB
CL110
OFFICE
CL109
230 SF
FLOOR PLAN - AREA
CL112 C2
CL118 A-301 223 SF
2
4/1/2021 11:42:05 AM

748 SF

9.8 8.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2

A3 LOWER LEVEL 1 PLAN - AREA 2 SHEET NUMBER


A-102.2

A-102.2
1/8" = 1'-0"
KEYNOTE LEGEND
RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
N10 101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

AREA 3 AREA 2 Structural Engineer


Fink Roberts & Petrie, Inc.
A 9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
EW01
CLOSET 732 N Capitol Avenue
G220A Indianapolis, Indiana 46204
32 SF 317-634-4672
CLASSROOM MENS R.R.
G203 G206
871 SF 165 SF

B
G3 STUDY AREA
G204
299 SF
CLASSROOM A-501
G222 A-201 C6
CLASSROOM
938 SF
G220 A3
733 SF EW01 A-622

WOMENS R.R.
G202
110 SF

M8A C

X G203

STAIR CIRCULATION D6
X
- - A-422
179 SF 1404 SF

X G208 G210

G210A

STG.
F
A-501 G210A
STAIR
-
D
3 G

G1 B7
A-401
128 SF
E
2
N10 D
CLASSROOM CLASSROOM CLASSROOM
G221 G219 STUDENT C
G208
858 SF 852 SF
809 SF AREA
G210
G5 A-501 588 SF B 1
E5 A
E

KEY PLAN

SEAL | DATE 04/01/21

COOK
GREENHOUSE
G219A
1266 SF

SHEET ISSUE
AREA 3 AREA 2 1 Construction Documents 04/01/21

C3 CRAPO LEVEL 2 PLAN (LL1)


A-102.3
1/8" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

CRAPO LEVEL 2
FLOOR PLAN - AREA
3 (LL1)
4/1/2021 12:07:04 PM

SHEET NUMBER

A-102.3
KEYNOTE LEGEND RHIT MOENCH
RENOVATION
N10 N9 N8 N7 N6 N5 A-201 N4 N3 N2 N1
5500 Wabash Avenue
A3
Terre Haute, Indiana
A 47803
AREA 3 AREA 2 FACULTYFACULTYFACULTY
FACULTYFACULTY
FACULTY FACULTYFACULTYFACULTYFACULTY FACULTYFACULTYFACULTYFACULTYFACULTYFACULTY DEPT. HEAD Owner
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE F105A
F137 F135 F133 F129 F127 F125 F123 F121 F119 F117 F115 F113 F111 F109 F107 238 SF
Rose-Hulman Institute of Technology
F131
133 SF 134 SF 133 SF 133 SF 134 SF 5500 Wabash Avenue
Terre Haute, Indiana 47803
CLASSROOM
STUDENT B ADMIN OFFICE 812-877-1511
G310 WORK AREA
940 SF F105 C3 A-201
CLASSROOM G304
CLASSROOM G306 A-201 193 SF
649 SF C6
G308
FACULTY FACULTY
OFFICE OFFICE FACULTYFACULTYFACULTYFACULTYFACULTY FACULTY FACULTY FACULTYFACULTYFACULTY FACULTY
CLOSET DATA
F132 F130 OFFICE OFFICE OFFICE OFFICE OFFICE COLLISION OFFICE OFFICE OFFICE OFFICE OFFICE
F114
G304A C F128 F126 F124 F122 F120 F116 F112 F110 F108 F106 F103
8 SF
FACULTY
ROOF
OFFICE
ACCESS
F101
G304B CORRIDOR
F132 Architect
RATIO
D 101 South Pennsylvania Street
Indianapolis, Indiana 46204
EQUIPMENT SERVER/EQUIP. WOMENS R.R.
REPAIR ROOM
317-633-4040
CLASSROOM CLASSROOM CLASSROOM 13 SEAT STORAGE E109
G317 G315 G313 E107A E107C 123 SF
CLASSROOM
CONF. 209 SF E104
860 SF 854 SF 824 SF 98 SF
G305 ELEV 1 1958 SF Structural Engineer
-
TECHNICIAN 84 SF
Fink Roberts & Petrie, Inc.
E OFFICE 9449 Priority Way W Dr #200
E107B Indianapolis, Indiana 46240
WORKSHOP 96 SF MENS R.R.
STORAGE AREA 3 AREA 2 317-872-8400
E107 E108
G305A 481 SF 242 SF

Mechanical / Electrical Engineer


F
OFFICE R.E. Dimond & Associates, Inc.
E102
158 SF
732 N Capitol Avenue
Indianapolis, Indiana 46204
A5
A-301 OFFICE 317-634-4672
E101
160 SF
G
OFFICE
REFERENCE OFFICE OFFICE
D113
ENERGY 150 SF (CONFERENCE) D108 D107
155 SF
CONVERSION ROOM 173 SF
AND POWER CLASSROOM D110
SYSTEMS D112 395 SF
LABORATORY OFFICE
H
580 SF
OFFICE OFFICE OFFICE
D114 D106
1469 SF
D111-1 D111 D109 164 SF
132 SF 149 SF
165 SF

OFFICE
D105
143 SF
J
OFFICE
ELECTRONIC D104
CALIBRATION 144 SF
LABORATORY
CIRCUITS D116 ECE LAB TECH
LEARNING
LABORATORY 115 SF D117
130 SF
CENTER DESIGN LAB OFFICE
K D115 D101-A D101 D103
1409 SF 612 SF 943 SF 165 SF
OFFICE
D118
98 SF
STORAGE OFFICE
AREA 2 AREA 2
D115A D102
97 SF 145 SF
L
INSTRUMENT
AREA 1 AREA 1
ROOM OFFICE F
EQUIPMENT
STORAGE
C114
517 SF
WORKSHOP/STORAGE C110
142 SF
3 G
C112
C115A
200 SF
236 SF
E
2
DIGITAL
ELECTRONIC
MECHATRONICS OFFICE D
M C111 C109
MICROCOMPUTER 945 SF 165 SF
LABORATORY
C115 C
A2
1300 SF
A-301 OFFICE
C108
142 SF
B 1
N
A

DYNAMIC MAIL ROOM KEY PLAN


SYSTEMS AND OFFICE OFFICE C104
CONTROLS C117 C118 51 SF

O LABORATORY 109 SF 116 SF SEAL | DATE 04/01/21


C116
1492 SF OFFICE ADMIN
SERVER WORKROOM / C103
168 SF
ROOM BREAKROOM
OFFICE C103A OFFICE
B107B
298 SF
C101A 279 SF C105
222 SF 227 SF

P ELECTRICAL
ROOM
B107A ELECTRICAL
227 SF STORAGE
ROOM B105A
B107 216 SF
33 SF CLASSROOM
B106 ADVANCED
Q 581 SF CIRCUIT SHEET ISSUE
STUDY AREA
144 OFFICE LABORATORY
B108B B105 1 Construction Documents 04/01/21
226 SF
154 SF 1278 SF
OFFICE
B108C E.I.T.
187 SF OFFICE
B108A B103C
154 SF 17 SF
R
BUSINESS TEST OFFICE
AND FINANCE ENGINEERING B103A SOLDERING OFFICE
CONFERENCE LAB 128 SF LAB B101 OFFICE
ROOM B104 B102 162 SF B100
B109 241 SF OFFICE 193 SF
196 SF
472 SF B103B
123 SF
S CUSTODIAL
ELEV 2
STORAGE
GM ROOM -
B110 47 SF
B111 123 SF
1794 SF

9.8 8.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
T
NEW MTL STUD CIRCULATION WORKROOM / OFFICE
OFFICE WRAP AT STEEL - OFFICE BREAKROOM A105
A140 COLUMNS 964 SF A102A A102B OFFICE 134 SF
229 SF
SERVER 149 SF 131 SF
OFFICE OFFICE ROOM ADMIN OFFICE A103
OFFICE OFFICE 181 SF
OFFICE
A136 A138 A100A A102 A106
A124 7.9A126 114 SF 113 SF 97 SF 252 SF 139 SF
U 137 SF 117 SF
WORKROOM / STORAGE
OFFICE A104B OFFICE
BREAKROOM
APPLICATIONS ELEC. A101 11 SF
A107
A122 348 SF
READING 288 SF A118A 138 SF
ROOM 14 SF ELEC. AND
STORAGE OFFICE STORAGE OFFICE STORAGE SAFE OFFICE OFFICE
A130 A120B A104
A120A 265 SF
A128 A118 A101A A104A A108
12 SF 137 SF
19 SF 108 SF 117 SF 14 SF 54 SF 141 SF
V CIRCULATION ADMIN OFFICE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
A120 A113 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
257 SF 179 SF COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
OFFICE
OFFICE A109
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE PROJECT NO. 19010.000
A121 205 SF
185 SF A123 A125 A127 A129 A117 A116 A115 A114 A112 A111 A110
125 SF 128 SF 127 SF 139 SF 124 SF 152 SF
125 SF 137 SF 125 SF 126 SF 138 SF SHEET TITLE
W FIRST LEVEL
C2 OVERALL FLOOR
A-301
PLAN
4/1/2021 11:42:21 AM

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

A5 FIRST LEVEL OVERALL PLAN SHEET NUMBER


A-103
1/16" = 1'-0"

A-103
AREA 2 STORAGE AREA 2
D115A
97 SF
CIRCULATION
-
1132 SF
OFFICE
D102
145 SF
KEYNOTE LEGEND RHIT MOENCH
D115A D102

L S3C C112A
RENOVATION
AREA 1
INSTRUMENT
S3C
C110
AREA 1 5500 Wabash Avenue
ROOM
C114
OFFICE
C110
Terre Haute, Indiana
517 SF

47803
142 SF
EQUIPMENT WORKSHOP/STORAGE
STORAGE C112
C115A S3C 236 SF
200 SF Owner
C112B Rose-Hulman Institute of Technology
S3C 5500 Wabash Avenue
Terre Haute, Indiana 47803
MECHATRONICS OFFICE
M C114 812-877-1511
C111 C109
DIGITAL 945 SF 165 SF
ELECTRONIC S3C
MICROCOMPUTER C109
LABORATORY
C115
1300 SF
A2
A-301 C108

OFFICE
CIRCULATION
C108
- 142 SF
5589 SF Architect
RATIO
N C111
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
MAIL ROOM 9449 Priority Way W Dr #200
C104 Indianapolis, Indiana 46240
OFFICE
OFFICE 51 SF 317-872-8400
DYNAMIC C118
C117
SYSTEMS AND 109 SF
116 SF
CONTROLS
O LABORATORY Mechanical / Electrical Engineer
C116 C101A
S3C R.E. Dimond & Associates, Inc.
1492 SF S3C C104
732 N Capitol Avenue
OFFICE ADMIN Indianapolis, Indiana 46204
C103 317-634-4672
SERVER 168 SF
ROOM
WORKROOM /
B107B BREAKROOM
4'-0" 298 SF S3C
OFFICE C103A OFFICE
CLEAN AGENT 279 SF
C101A C105
CLOSET S3C 222 SF 227 SF
S3A C116A C105
C116A
2'-0"

S3A

P
ELECTRICAL
ROOM
B107A
227 SF B107

ELECTRICAL STORAGE
ROOM B105A
216 SF
B107
33 SF
S3C
CLASSROOM
B106
581 SF

Q
ADVANCED
STUDY AREA CIRCUIT
144 OFFICE LABORATORY
226 SF
B108B B105
154 SF 1278 SF
S3C
(8) QTY VENDING MACHINES B106
TO BE RELOCATED HERE OFFICE
FROM THEIR EXISTING B108C
LOCATION IN ROOM EL103. F
3
187 SF
E.I.T. G
OFFICE
B103C
B108A
154 SF B108A
17 SF S3C E
2
R D

OFFICE C
B103A
128 SF
BUSINESS
AND FINANCE
TEST
ENGINEERING
SOLDERING
LAB
OFFICE
B101
162 SF
B 1
CONFERENCE LAB B102 OFFICE
ROOM B104 193 SF B100 A
241 SF 196 SF
S3C B109 B104
472 SF OFFICE
B103B
123 SF KEY PLAN
S3C

S SEAL | DATE 04/01/21

CUSTODIAL S3C ELEV 2


STORAGE -
B110 47 SF X318
GM ROOM 123 SF
B111 B110
1794 SF

9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2

T A100
SHEET ISSUE
A105
1 Construction Documents 04/01/21
C1 CIRCULATION A1 OFFICE
A-422 A-422 WORKROOM /
- A105
964 SF
OFFICE BREAKROOM
OFFICE A102A A102B
134 SF
A140 149 SF 131 SF
X 229 SF OFFICE
X
A103
SERVER A102A 181 SF
OFFICE OFFICE OFFICE ROOM ADMIN OFFICE OFFICE
OFFICE A126 A136 A138 A100A A102
114 SF
A106
A124 117 SF 113 SF 97 SF 252 SF 139 SF
A106
137 SF
D1 03
A-422
U A103
STORAGE
A104B A107
WORKROOM / OFFICE 11 SF
BREAKROOM A101 OFFICE
A122 348 SF A104 A107
ELEC. 138 SF
288 SF
A118A
APPLICATIONS 14 SF 03
READING
ROOM STORAGE ELEC. AND
STORAGE A130 OFFICE OFFICE SAFE OFFICE
A120B STORAGE A104 OFFICE
A120A 265 SF A128 12 SF A118 A101A A104A
19 SF 108 SF 117 SF 54 SF
137 SF A108
14 SF
141 SF
A118A A101A A108

V A118
CIRCULATION ADMIN OFFICE
A113 A113 A109
A120 03
257 SF 179 SF
A117 A115 A114 A112 A111 A110

OFFICE
A109
OFFICE 205 SF COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
A121 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
185 SF OFFICE A115 A114 A112 A111 A110 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A123 A125 A127 A129 A117 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
125 SF 128 SF 127 SF 139 SF 124 SF A116 125 SF 137 SF 125 SF 126 SF 138 SF
152 SF
PROJECT NO. 19010.000
SHEET TITLE
W FIRST LEVEL FLOOR
PLAN - AREA 1
4/1/2021 11:42:29 AM

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1

C2
A2 FIRST LEVEL PLAN A-301
SHEET NUMBER
A-103.1

A-103.1
1/8" = 1'-0"
KEYNOTE LEGEND
RHIT MOENCH
00-A1
00-A2
CENTER WALL ON COLUMN GRID LINE
CENTER WALL ON MULLION CENTER LINE
RENOVATION
N10 N9 N8 N7 N6 N5 A-201
N4 N3 N2 N1 00-B2 ALIGN FINISH FACE OF WALL TYPE WITH FACE OF
WINDOW OPENING JAMB 5500 Wabash Avenue
A3 Terre Haute, Indiana
A3 A3 A7 A3 A3 A3 A3 A3
47803
A-622 A-622 A-622 A-622
A3
EW01 EW01 A-622 EW01 EW01 A-622 EW01 EW01 A-622 EW01 A-622 EW01
6" CLEAR EW01
TYP. A-622 Owner
A
Rose-Hulman Institute of Technology
00-A2 00-A2 00-A2 00-A2 00-A2 00-A2 00-A2 00-A2 5500 Wabash Avenue

9'-0" CLEAR
AREA 3 AREA 2 Terre Haute, Indiana 47803
S3C S3C.A 812-877-1511
FACULTY FACULTY FACULTY FACULTY
FACULTY FACULTY FACULTY FACULTY FACULTY DEPT. HEAD
OFFICE OFFICE OFFICE OFFICE FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY
OFFICE OFFICE OFFICE OFFICE OFFICE F105A
F135 F133 F131 F129 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
F137 133 SF F127 F125 F123 F107 E8 A-502 238 SF
EW01
130 SF
134 SF 133 SF 133 SF
134 SF 134 SF 133 SF F121 F119 F117 F115 F113 F111 F109 131 SF
EW01
133 SF 133 SF 133 SF 132 SF 132 SF 135 SF 135 SF

B1 A-502 B1 B1 B1 S3A.1.A
A-502 B1 A-502 A-502 A-502 A-502 B1 B1 A-502 B1 A-502 B1 B1 B1 A-502 A-502 B1 B1 A-502
A-502 B1 A-502 A-502 A-502 B1 00-B2
O.H. O.H. O.H. O.H. O.H. 6" CLEAR O.H. O.H. O.H. F105A
F137 F135 F133 F131 F129 F127 F125 F123 F121 F119 F117 F115 F113 F111 F109 F107

4'-5 1/8"
B 00-A1 00-A1 00-A1 00-A1 00-A1 00-A1

3'-0" MIN
00-A1
3'-8"

S3C.A

6" CLEAR

6'-1 3/4"
A-201 Architect
B3 A2 A2 A2 A2 A2 A2 C3
F132 F130
A-532 A-532 A-532 A-532 A-532 A-532 A-532 ADMIN OFFICE RATIO

ALIGN
O.H. F105 101 South Pennsylvania Street
F128 F126 F124 F122 F120 F116 F114 F112 F110 F108

ALIGN
A-201 F106
C6 F105
193 SF Indianapolis, Indiana 46204
A-502 B1 O.H. O.H. O.H. O.H. O.H. 00-A2 317-633-4040
1'-1"
EW01 EW01
FACULTY FACULTY A-502 B3 B3 A-502 A-502 B3 B3 A-502 B3 E4 A-502 B3 B3 A-502 A-502 B3 B3 A-502
A-502
OFFICE OFFICE FACULTY A-401 Structural Engineer
F132 FACULTY COLLISION FACULTY FACULTY FACULTY FACULTY A-502 FACULTY A3
F130 FACULTY FACULTY FACULTY FACULTY DATA Fink Roberts & Petrie, Inc.
134 SF 5'-0 1/4" (+/-) OFFICE F116 OFFICE OFFICE OFFICE OFFICE OFFICE A-622
131 SF OFFICE OFFICE OFFICE OFFICE
F122 271 SF F114 F112 F110 F108 F106 F103 9449 Priority Way W Dr #200
EQ EQ F128 F124 F120 F103
F126 133 SF 108 SF 132 SF 132 SF 134 SF 134 SF B1 143 SF
Indianapolis, Indiana 46240
C 132 SF 132 SF
133 SF 132 SF
JAN
F100 317-872-8400
A5 A5 B1
A-532 A5 A5 FACULTY
CIRCULATION 00-A1 00-A1 A-532 00-A1 A-532 00-A1 A-532
F101
OFFICE 7
- X
A-401 Mechanical / Electrical Engineer
128 SF O.H. A-502 F101
141 SF
X R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
F100

13'-1 3/4"
Indianapolis, Indiana 46204

6'-0" 6"
F100A 317-634-4672
STAIR
-
119 SF

F100C F100B E104A


D

EQUIPMENT
REPAIR ROOM SERVER/EQUIP.
E107A STORAGE
209 SF E107C CLASSROOM
98 SF E104
1958 SF
S3C
ELEV 1 S3C
E107A -
84 SF
S3C WOMENS R.R.
E E109
123 SF
TECHNICIAN
OFFICE
E107B E107B
AREA 3 AREA 2 96 SF
S3C
WORKSHOP MENS R.R.
E107 E108
481 SF 242 SF

E107
CIRCULATION
-
F
3
1514 SF
G
F
INCLUDE IN ALT. BID NO. A-5 REMOVAL OF
EXISTING DISPLAY PEDESTALS UNDER STAIRS OFFICE
E
2
E102 E102A
AND REPLACING WITH PLATFORM TO MATCH ONE
SHOWN UNDER STAIRS IN LL1 CAFE AREA 158 SF D

C
A5
A-301
OFFICE
B 1
E101
160 SF A

G E100
KEY PLAN

OFFICE SEAL | DATE 04/01/21


D113 OFFICE OFFICE
150 SF D108 D107
155 SF
173 SF
REFERENCE
(CONFERENCE)
ROOM
D110 D108 D107
ENERGY CLASSROOM 395 SF S3C
CONVERSION D112
AND POWER 580 SF
SYSTEMS S3C
LABORATORY OFFICE
H OFFICE
D114 OFFICE D106
D111 OFFICE 164 SF
1469 SF D111-1 149 SF
132 SF D109
165 SF D106
SHEET ISSUE
D109 1 Construction Documents 04/01/21
D112 D110
D105

OFFICE
D114 D105
143 SF

J D114A

OFFICE
D104
144 SF
D104
D116B D117

ECE LAB TECH


D117 S3C D103
CIRCUITS ELECTRONIC 130 SF LEARNING S3C
LABORATORY CALIBRATION CENTER DESIGN LAB OFFICE
K D115 LABORATORY D101-A D101 D103
1409 SF 612 SF 943 SF
D116 165 SF
115 SF

OFFICE
D118 S3C
98 SF

D116A D118
AREA 2 STORAGE AREA 2
CIRCULATION OFFICE
D115A - D102
97 SF
1132 SF 145 SF COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
D115A D102 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

L S3C C112A
PROJECT NO. 19010.000
S3C AREA 1
AREA 1
INSTRUMENT C110 SHEET TITLE
ROOM
C114
517 SF
OFFICE
C110
142 SF
FIRST LEVEL FLOOR
EQUIPMENT
STORAGE
C115A
WORKSHOP/STORAGE

S3C
C112
236 SF
PLAN - AREA 2
200 SF
4/1/2021 11:42:37 AM

9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
C2
A-301
A2 FIRST LEVEL PLAN SHEET NUMBER
A-103.2
1/8" = 1'-0"

A-103.2
RHIT MOENCH
KEYNOTE LEGEND
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

N10
Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

A
Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
AREA 3 AREA 2
732 N Capitol Avenue
Indianapolis, Indiana 46204
FACULTY
OFFICE
317-634-4672
EW01
F137
130 SF
PATCH FLOOR WHERE
DRAIN REMOVED IN
THIS AREA

D3 D1 F137
B
A-502 E4 A-502 E5
A-502
F132
CLASSROOM CLASSROOM STUDENT
G310 G306 WORK AREA A-201
940 SF CLASSROOM C6
853 SF G304
G308 649 SF
ROOF EW01
ACCESS FACULTY
A7 CLOSET
A-351 G304B OFFICE
G304A

4'-4"
8 SF F132
134 SF

G304B C
G308B G308A G306B G306A G304

CIRCULATION 5'-2"
-
1390 SF X

G305
F
3 G
E
2
D
13 SEAT D
CONF.
G305
C
N10
CLASSROOM
G317
CLASSROOM
G315
CLASSROOM
G313
G3
G305A
B 1
860 SF 854 SF 824 SF
S3A.C
G4 A-502 G1 A

KEY PLAN
STORAGE
G305A
E SEAL | DATE 04/01/21

AREA 3 AREA 2

E7
A-401

F
SHEET ISSUE
1 Construction Documents 04/01/21

C3 CRAPO LEVEL 3 PLAN (L1)


A-103.3
1/8" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

CRAPO LEVEL 3
FLOOR PLAN - AREA
3 (L1)
4/1/2021 11:42:41 AM

SHEET NUMBER

A-103.3
RHIT MOENCH
KEYNOTE LEGEND
RENOVATION
N10 N9 N8 N7 N6 N5 A-201 N4 N3 N2 N1 5500 Wabash Avenue
A3
Terre Haute, Indiana
A
CONFERENCE
47803
AREA 3 AREA 2 ROOM OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE Owner
F230 F228 F226 F224 F222 F220 F218 F216 F214 F212 F210
285 SF 202 SF 164 SF 163 SF 162 SF 162 SF 163 SF 163 SF 162 SF 162 SF 164 SF Rose-Hulman Institute of Technology
5500 Wabash Avenue
CIRCULATION STORAGE Terre Haute, Indiana 47803
B ADMIN OFFICE - F208 812-877-1511
F231 1224 SF 25 SF C3 A-201
BREAK AREA
182 SF
A-201 C6 F207
WORKROOM / USABILITY 58 SF
OFFICE
BREAKROOM LAB F206
153 SF
F233 F225A OFFICE
C 170 SF 69 SF
CSSE LAB CSSE LAB F205
148 SF
USABILITY F225 F217 OFFICE
LAB CONTROL 1428 SF 1337 SF
F204
ROOM 158 SF
STAIRWELL F225B
- CUSTODIAL 70 SF
OFFICE
275 SF - F203 Architect
149 SF
35 SF
RATIO
D 101 South Pennsylvania Street
Indianapolis, Indiana 46204
MECHANICAL 317-633-4040
ROOM CLASSROOM
G116 E104
556 SF ELEV 1 WOMENS R.R. 1958 SF
- E202 Structural Engineer
84 SF 140 SF
E Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
MECHANICAL Indianapolis, Indiana 46240
ROOM 317-872-8400
AREA 3 AREA 2
E201
451 SF

F Mechanical / Electrical Engineer


W01 W02
CIRCULATION R.E. Dimond & Associates, Inc.
-
1838 SF
732 N Capitol Avenue
SEATING Indianapolis, Indiana 46204
A5
E200
A-301 317-634-4672

G
OFFICE OFFICE
D222 D208
119 SF
STORAGE 106 SF
D223A OFFICE OFFICE OFFICE OFFICE
OFFICE 10 SF D220 D221 D209 OFFICE
D224
D223 131 SF
146 SF 149 SF 157 SF D207
119 SF 123 SF
H
OFFICE CONFERENCE STUDENT OFFICE
D225 STORAGE D219A STUDY AREA D206
125 SF 134 SF 124 SF
D226A D210
10 SF
OFFICE 263 SF
OFFICE D227 OFFICE
D226 144 SF D205
120 SF
127 SF
J STORAGE /
WORKROOM OFFICE OFFICE
D226C D218 D204
OFFICE 78 SF 137 SF OFFICE 120 SF
D228 ADMIN OFFICE D211
257 SF D229 134 SF OFFICE
209 SF D203
120 SF
K
OFFICE FACULTY OFFICE
CONFERENCE
D230 STORAGE OFFICE D202
ROOM
124 SF D215B 124 SF
D226D 145 SF
D212
10 SF OFFICE 287 SF OFFICE
AREA 2 OFFICE D232 AREA 2
D201
D231 144 SF 120 SF
126 SF
L
AREA 1 OFFICE AREA 1
F
MECHANICAL
ROOM
C215
MECHANICAL
ROOM
C214
OFFICE
C212
C211
120 SF 3 G

557 SF 561 SF 158 SF OFFICE


C210
E
2
124 SF
M IT CLOSET D
C200B OFFICE
STAFF 35 SF C209
STUDY AREA RESOURCES C
A2 119 SF
A-301 - OPEN TO C200
217 SF BELOW OFFICE
259 SF
STORAGE
C200A
C208
119 SF
B 1
N 36 SF
A
OFFICE
C216 OFFICE
255 SF
C217
KEY PLAN
232 SF

O SEAL | DATE 04/01/21


MECHANICAL MECHANICAL ADMIN
ROOM ROOM C205 OFFICE
C218 C201 219 SF C206
562 SF 569 SF 270 SF

P
STORAGE
MECHANICAL C205B
ROOM 18 SF
W9NAA ROSE
MECHANICAL TECH RADIO B202
ROOM CLUB
335 SF
B203 B204
128 SF
Q PROJECTION 96 SF

ROOM STUDENT
SHEET ISSUE
B111A CONFERENCE BBE HIVE OFFICE 1 Construction Documents 04/01/21
234 SF
ROOM B205 B201
229 SF
B205A 284 SF
136 SF

R
DIGITAL
SYNTHETIC
SIGNAL
BIOLOGY
PROCESSING
LABORATORY
LAB
B206
460 SF
B200
1109 SF

S
ELEV 2
-
GM ROOM MECHANICAL 42 SF
B111 ROOM
1794 SF
B207
469 SF
9.8 8.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
T
CUSTODIAL
CIRCULATION STORAGE MECHANICAL
- A223A ROOM
ADMIN OFFICE OFFICE 151 SF 27 SF MENS R.R.
A301
A218 A218A A223 590 SF CLASSROOM
409 SF 187 SF WOMENS R.R. 317 SF A202
A222 672 SF
7.9 SITTING AREA 125 SF STORAGE /
U A220 PROJECTOR
BREAKROOM A202A
OFFICE OFFICE OFFICE
A200 17 SF
A218C A218B 166 SF A201
122 SF 153 SF 134 SF
WORK AREA / OFFICE
ELECTRICAL STORAGE A203A
CIRCULATION ROOM A203 116 SF
V - A200A 97 SF
55 SF OFFICE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
A203B DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
WORKROOM 115 SF COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
OFFICE A207 OFFICE
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE A209 ADMIN OFFICE113 SF OFFICE OFFICE OFFICE A203D
A217 A216 A215 A214 A213 A212 A211 A210 226 SF A206 A205 A204 137 SF OFFICE PROJECT NO. 19010.000
108 SF 112 SF 115 SF 112 SF 115 SF 113 SF 113 SF 120 SF A208 114 SF 112 SF A203C
114 SF
119 SF
135 SF SHEET TITLE
W
SECOND LEVEL
C2
OVERALL FLOOR
S10 S9 S8 S7 S6
A-301
S5 S4 S3 S2 S1 PLAN
4/1/2021 11:42:54 AM

A5 SECOND LEVEL OVERALL PLAN


A-104
1/16" = 1'-0"
SHEET NUMBER

A-104
FACULTY
OFFICE CONFERENCE
STORAGE D215B ROOM
D226D 145 SF D212
10 SF OFFICE OFFICE 287 SF
D214 D215A
OFFICE
D231
D232
S3C D201 OFFICE
KEYNOTE LEGEND
S8A
OFFICE
D231
126 SF D226D
144 SF

D232 D214 S8A


D201
120 SF
RHIT MOENCH
L RENOVATION
S8A

INFILL WITH LIKE WALL OFFICE 5500 Wabash Avenue


CONSTRUCTION, C211
MECHANICAL
VERIFY WALL TYPE IN
FIELD, ALIGN TO MECHANICAL
OFFICE
S3C C211
120 SF
Terre Haute, Indiana
ROOM ROOM
C215
557 SF
EXISTING FINISH
FACES C214
561 SF
C212
158 SF
47803
S3C C210
OFFICE Owner
C210
C215 C214 C212 124 SF Rose-Hulman Institute of Technology
5500 Wabash Avenue
M Terre Haute, Indiana 47803
IT CLOSET 812-877-1511
S8A
S3C C200B S3C
35 SF OFFICE
C209
C209 119 SF
STAFF
STUDY AREA
RESOURCES
A2 - D3
A-301 217 SF
A-422 C200
259 SF

OPEN TO OFFICE
BELOW C208
S3C STORAGE S3C 119 SF
S8A
C200A Architect
36 SF
N RATIO
101 South Pennsylvania Street
C216 Indianapolis, Indiana 46204
317-633-4040

OFFICE Structural Engineer


C216
255 SF Fink Roberts & Petrie, Inc.
OFFICE
C217 9449 Priority Way W Dr #200
232 SF Indianapolis, Indiana 46240
C217 317-872-8400

O
Mechanical / Electrical Engineer
INFILL WITH LIKE WALL S3C R.E. Dimond & Associates, Inc.
CONSTRUCTION, 732 N Capitol Avenue
VERIFY WALL TYPE IN ADMIN Indianapolis, Indiana 46204
MECHANICAL FIELD, ALIGN TO MECHANICAL
ROOM ROOM C205 OFFICE 317-634-4672
EXISTING FINISH 219 SF
C218 FACES C201 C206
562 SF 569 SF 270 SF

C218 C201

STORAGE
C205B
18 SF

MECHANICAL
ROOM
B203
B202
335 SF
MECHANICAL W9NAA ROSE
ROOM TECH RADIO B202
B203 CLUB
128 SF B204 S3A
96 SF

Q
PROJECTION B111A
B201
ROOM
B111A
234 SF OFFICE
STUDENT BBE HIVE B201
CONFERENCE B205 229 SF S3C
ROOM 284 SF
B205A
136 SF

F
S300-1
STAIR
300-1
S3C
3 G

R
E
2
D

C
SYNTHETIC DIGITAL
BIOLOGY
LABORATORY
B206
SIGNAL
PROCESSING
LAB
B 1
460 SF B200
1109 SF
A

KEY PLAN
S
SEAL | DATE 04/01/21
ELEV 2
-
42 SF

GM ROOM
B111 MECHANICAL
S5 S4 S3 1794 SF
ROOM
B207 B207
469 SF

S3A
T 9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2

T A220
A202B
SHEET ISSUE
A223
MECHANICAL CIRCULATION 1 Construction Documents 04/01/21
ROOM - MECHANICAL
151 SF
A301 ROOM
A222
S3A OFFICE A301
ADMIN OFFICE A5 MENS R.R. 590 SF
A218 A218A A223
A2 187 SF CLASSROOM
409 SF 317 SF
A-351 A3 A7 A202
A301
A-422 CUSTODIAL
WOMENS R.R. STORAGE
672 SF
A222 A223A
U 125 SF A301
A218A 27 SF
SITTING AREA
LADDER

2'-0" CLEAR
11'-10 3/4" +/-

U
11'-5 1/4" +/-

A218C A218B A220 STORAGE /


SAFETY B1
A5 PROJECTOR
GATE A-104.1
A-421 A202A
S3C BREAKROOM
ABOVE 17 SF
A218
OFFICE OFFICE A200 OFFICE
A218C A218B 166 SF A202C A202 A202A
A3 A201
A3 A-351
122 SF 153 SF 134 SF
A-351 SIM.
2'-0" CLEAR S3C
A203
WORK AREA / OFFICE
A200 A201
STORAGE A203A
ELECTRICAL 116 SF
V +/- 16'-6 7/8" V.I.F. ROOM A203 A203A
A200A 97 SF
55 SF
V
A203B
OFFICE
A203D
A203B
A217 A216 A215 A214 A213 A212 A211 A210 A208 A207 A206 A205 A204 115 SF

B1 ATTIC MEZZANINE OFFICE OFFICE A203C


A-104.1 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE A209 OFFICE OFFICE A203D
1/8" = 1'-0" 226 SF WORKROOM OFFICE 137 SF COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
A217 A216 A215 A214 A213 A212 A211 A210 ADMIN OFFICE A206 A205 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
108 SF 112 SF 115 SF 112 SF 115 SF 113 SF 113 SF 120 SF A207 114 SF 112 SF A204 OFFICE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A208 113 SF 114 SF COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
119 SF A203C
135 SF
PROJECT NO. 19010.000
SHEET TITLE
W
SECOND LEVEL
FLOOR PLAN - AREA
1
4/1/2021 11:43:03 AM

C2
A-301

S10 S9 S8 S7 S6 S5 S4 S3 S2 S1 SHEET NUMBER


SECOND LEVEL PLAN
A3
A-104.1
1/8" = 1'-0" A-104.1
KEYNOTE LEGEND
RHIT MOENCH
N10 N9 N8 N7 N6 N5 A-201
N4 N3 N2 N1
RENOVATION
A3 5500 Wabash Avenue
Terre Haute, Indiana
C7
A-622 47803
A
Owner
Rose-Hulman Institute of Technology
CONFERENCE 5500 Wabash Avenue
ROOM OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE Terre Haute, Indiana 47803
F230 F228 F226 F224 F222 F220 F218 F216 F214 F212 F210 812-877-1511
285 SF 202 SF 164 SF 163 SF 162 SF 162 SF 163 SF 163 SF 162 SF 162 SF 164 SF
E8 A-502

A-502 B1

CIRCULATION STORAGE
B - F208
ADMIN OFFICE 1224 SF 25 SF
F231 C3 A-201
182 SF
BREAK AREA Architect
A-201 USABILITY F207 RATIO
C6 58 SF
LAB 101 South Pennsylvania Street
OFFICE
F225A Indianapolis, Indiana 46204
69 SF F206
WORKROOM / 153 SF 317-633-4040
BREAKROOM
F233
170 SF
OFFICE Structural Engineer
F205
USABILITY 148 SF
Fink Roberts & Petrie, Inc.
C LAB CONTROL CSSE LAB CSSE LAB
F225 9449 Priority Way W Dr #200
ROOM F217 Indianapolis, Indiana 46240
1428 SF
F225B 1337 SF
70 SF OFFICE 317-872-8400
F204 B4
158 SF

Mechanical / Electrical Engineer


A-502
STAIRWELL R.E. Dimond & Associates, Inc.
-
275 SF
OFFICE 732 N Capitol Avenue
CUSTODIAL F203
- Indianapolis, Indiana 46204
149 SF
35 SF 317-634-4672

S3C

C5 MECHANICAL
ROOM CLASSROOM
G116 WOMENS R.R. E104
A-403 556 SF E202 1958 SF
A1 A-502 A5 140 SF
ELEV 1
- S3C
84 SF

G116

E
S2C

C6 MECHANICAL
ROOM
E201
C5 A-422 451 SF
A-403 C1

2'-0" CLEAR
C3
E201

F F
W01 D3
W02 A-423
S3C.A 3 G

E5
A-421
CIRCULATION
- S3C.A
E
2
1838 SF
D
A-404
SEATING A-502 B7 B5 A-502
A5 E200 C
A-301 E4

B 1
A
G E200

S8A S8A
KEY PLAN
OFFICE D222 OFFICE
D222 D208
D208
119 SF D221 106 SF SEAL | DATE 04/01/21
STORAGE
S8A S3C
D223A
10 SF OFFICE OFFICE OFFICE
OFFICE D220
D223 D224 D221 D209 S3C OFFICE
OFFICE 146 SF
149 SF 157 SF
131 SF D207
D223
D224 D220 D209 123 SF
119 SF D223A

D225
OFFICE CONFERENCE OFFICE
D225 D219A D206
125 SF 134 SF D206 124 SF
STORAGE OFFICE STUDENT S3C
D226A
SHEET ISSUE
D219U STUDY AREA
10 SF D210 1 Construction Documents 04/01/21
OFFICE 263 SF
D226 D227 S3C D205
OFFICE OFFICE
OFFICE 144 SF
D219V D205
D226 120 SF
127 SF D226A D227 S8A

J
STORAGE / S3C
WORKROOM 1'-8" CLEAR
S8A
D226C OFFICE OFFICE
78 SF S3C
D218 D204
D204
137 SF 120 SF
OFFICE
OFFICE D211
S8A 134 SF
D228
257 SF ADMIN OFFICE OFFICE S3C
D217 D203
D229 D216 OFFICE
209 SF OFFICE D203
D229 D216 D217 D211 S8A 120 SF
D217A

K
STORAGE
D230
D217A D212
OFFICE OFFICE
D230 FACULTY D202
124 SF OFFICE CONFERENCE 124 SF
STORAGE D215B ROOM S3C
D226D 145 SF D212
10 SF OFFICE OFFICE 287 SF
D214 D215A
OFFICE D201 OFFICE
D231 S3C
OFFICE D232 D201
144 SF
D231 120 SF
126 SF D226D D232 D214 S8A
S8A COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
L DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

S8A
PROJECT NO. 19010.000
INFILL WITH LIKE WALL OFFICE
CONSTRUCTION, C211
C211 SHEET TITLE
VERIFY WALL TYPE IN S3C 120 SF
MECHANICAL
ROOM
FIELD, ALIGN TO
EXISTING FINISH
MECHANICAL
ROOM OFFICE SECOND LEVEL
C212
C215
557 SF
FACES C214
561 SF 158 SF
FLOOR PLAN - AREA
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
2
4/1/2021 11:43:11 AM

C2
A-301

A3 SECOND LEVEL PLAN SHEET NUMBER


A-104.2

A-104.2
1/8" = 1'-0"
GENERAL ROOFING NOTES
A. THESE GENERAL NOTES APPLY TO ROOF DRAWINGS.
B. VERIFY SIZE, LOCATION AND NUMBER OF ROOF
RHIT MOENCH
RENOVATION
PENETRATIONS INCLUDING VENTS, PIPES, CURBS, ROOF
DRAINS, CONDUITS, ETC. PROVIDE NEW FLASHING AND
SEAL PENETRATIONS WHETHER OR NOT INDICATED ON THE
DRAWINGS.

A-201
C. COMPLETE WORK ABOVE ROOF, SUCH AS MASONRY,
WELDING, MASONRY RESTORATION, ETC., PRIOR TO
5500 Wabash Avenue
A3
STARTING ROOFING WORK.
D. VERIFY AND MAINTAIN ROOF SLOPES AND DRAINAGE
PATTERNS. TEST FOR AND CORRECT ANY PONDING
Terre Haute, Indiana
CONDITIONS.
E. REPAIR AND REPLACE ROOFING SYSTEM OR STRUCTURE 47803
DAMAGED BY IMPROPER STORAGE, CONSTRUCTION
ACTIVITIES, OR LACK OF ADEQUATE TEMPORARY Owner
PROTECTION. THIS ALSO INCLUDES INTERIOR DAMAGE TO
FINISHES, EQUIPMENT, FURNISHINGS, ETC., RESULTING
Rose-Hulman Institute of Technology
FROM LEAKS. 5500 Wabash Avenue
F. NEW BLOCKING SHALL BE PRESERVATIVE-TREATED WOOD. Terre Haute, Indiana 47803
G. PAINT EXTERIOR LADDERS, BRACKETS, ETC., UNLESS 812-877-1511
C3 A-201 NOTED OTHERWISE.
A-201 H. CAP FASTENERS THAT PENETRATE ROOF DECK IN AREAS
C6 NOT CONCEALED BY CEILINGS WITH WIRE NUTS OR OTHER
MEANS ACCEPTABLE TO ARCHITECT UNLESS OTHERWISE
INDICATED. AREAS SUCH AS JANITOR CLOSETS, STORAGE
ALTERNATE: SHINGLE ROOF REPLACEMENT ROOMS, MECHANICAL AND ELECTRICAL EQUIPMENT
ROOMS, ETC., ARE EXEMPT FROM THIS REQUIREMENT
09 UNLESS OTHERWISE INDICATED.
I. REFER TO WALL SECTIONS NOTED ON ROOF PLANS FOR
INFORMATION.
J. REFER TO MECHANICAL DRAWINGS TO COORDINATE ROOF
CONDUCTOR LOCATIONS. Architect
T REV. 03/31/09 RATIO
101 South Pennsylvania Street
D.S. GENERAL RE-ROOFING NOTES Indianapolis, Indiana 46204
317-633-4040
1/2" : 1'-0" 01

DW
(VIF) A. THESE GENERAL NOTES APPLY TO ROOF DRAWINGS.

1/4" : 1'-0"
01 B. WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID Structural Engineer
UNLESS SPECIFICALLY NOTED TO BE BY ALTERNATE BID.
Fink Roberts & Petrie, Inc.

1/4" : 1'-0"

1/4" : 1'-0"
C. FIELD VERIFY CONDITIONS AND COORDINATE WITH
1/2" : 1'-0" 1/2" : 1'-0"
D.S. APPROPRIATE TRADES PRIOR TO STARTING 9449 Priority Way W Dr #200
(VIF) (VIF) CONSTRUCTION. IF DISCREPANCIES ARE FOUND BETWEEN Indianapolis, Indiana 46240
01 1/2" : 1'-0" 01 CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS,
317-872-8400

1/4" : 1'-0" 1/4" : 1'-0"


(VIF) NOTIFY ARCHITECT IMMEDIATELY.
02 8
A-202 D. PAINT EXTERIOR LADDERS, BRACKETS, ETC., UNLESS
OTHERWISE INDICATED.
A3

1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
E. PROTECT EXISTING SURFACES TO REMAIN IN AREAS Mechanical / Electrical Engineer
02 W01 D.S. D1 A-322 02
W02 3 ADJACENT TO DEMOLITION WORK. PROVIDE PLYWOOD
PROTECTION OVER EXISTING ROOF MEMBRANE AS R.E. Dimond & Associates, Inc.
REQUIRED. 732 N Capitol Avenue

7" / 12"

7" / 12"
A6 F. REPAIR FINISHES AND SURFACES LEFT EXPOSED BY
A5 A-322 Indianapolis, Indiana 46204
A-301 DEMOLITION OR REMOVAL OF EQUIPMENT USING NEW 317-634-4672
D.S. MATERIALS TO MATCH SURROUNDING SURFACES
10 10 INCLUDING ROOF DECK, SUBSTRATE, BLOCKING, ETC.
REPAIR EXISTING FINISHES TO CORRECT DEFECTS EITHER
1/2" : 1'-0" 1/2" : 1'-0" 1/2" : 1'-0" CAUSED OR EXPOSED BY DEMOLITION WORK OR
D.S.
(VIF) (VIF) (VIF) 1/2" : 1'-0" EQUIPMENT REMOVAL INCLUDING MASONRY, SHEET
(VIF) METAL, ETC. AREAS NOTED ON THE DRAWINGS TO BE
07 07 REPAIRED OR PATCHED ARE GIVEN FOR REFERENCE AND

1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
TYP. TYP. SHALL NOT BE INTERPRETED TO LIMIT THE SCOPE OF
WORK.
G. PATCH EXISTING CEILING AND ROOF CONSTRUCTION AT
ROOF PLAN NOTES ABANDONED PENETRATION LOCATIONS WITH NEW
MATERIALS AS REQUIRED TO RECEIVE NEW FINISHES AND
A3 TO MAINTAIN ORIGINAL FIRE RATING OF ASSEMBLY WHERE
01 NEW SINGLE PLY MEMBRANE ROOFING OVER A-321 APPLICABLE.
H. REFER TO WALL SECTIONS NOTED ON ROOF PLANS FOR
SLOPED INSULATION UTILIZING EXISTING ADDITIONAL DEMOLITION INFORMATION.
WOOD OR METAL DECK. FLASH AROUND ALL I. SELECTIVE DEMOLITION, SUCH AS ROOF PENETRATIONS

1/4" : 1'-0"

1/4" : 1'-0"
EXISTING PENETRATIONS AND CURBS D.S. FOR INSTALLATION OF NEW MECHANICAL OR ELECTRICAL
05 08 06 06 08 05 WORK, SHALL BE THE RESPONSIBILITY OF THE
02 NEW STANDING SEAM METAL ROOFING OVER

1/4" : 1'-0"

1/4" : 1'-0"
TYP. TYP. TYP. TYP. CONTRACTOR OR TRADE REQUIRING THE DEMOLITION.
NEW ROOF SUBSTRATE REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR
1/2" : 1'-0" ADDITIONAL DEMOLITION INFORMATION.
05 REPAIR EXISTING MASONRY SURROUNDING (VIF) J. REMOVE EXISTING GRAVEL BALLAST, ROOF MEMBRANE,
LIMESTONE OVERFLOWS AND DOWN FACE OF 1/2" : 1'-0" 1/2" : 1'-0" 1/2" : 1'-0"
INSULATION, THERMAL AND VAPOR BARRIERS, CANTS,
BUILDING AS REQUIRED FLASHING, COUNTERFLASHING AND COPING DOWN TO
(VIF) (VIF) (VIF)
A6 EXISTING STRUCTURAL ROOF DECK UNLESS NOTED
06 NEW SINGLE PLY MEMBRANE ROOFING OVER A-350 OTHERWISE. PLACE NEW ROOFING SYSTEM DIRECTLY
01 OVER EXISTING ROOF DECK.
NEW DUCT CHASE ENCLOSURE AS REQUIRED
K. REMOVE EXISTING SHINGLES, UNDERLAYMENT, FLASHING,
BY MEP NOTES AND DRAWINGS, REFERENCE

1/4" : 1'-0"

1/4" : 1'-0" 1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
GUTTERS, AND INSULATION DOWN TO EXISTING
MEP NARRATIVE STRUCTURAL ROOF DECK UNLESS NOTED OTHERWISE.
A-202 A-202 PLACE NEW ROOFING SYSTEM DIRECTLY OVER EXISTING
07 NEW DUAL ROOF DRAIN WITH OVERFLOW IN B1 D.S. A1
ROOF DECK.
EXISTING ROOF DRAIN LOCATION L. REMOVE EXISTING ASPHALT AND MASTIC MATERIAL FROM
PARAPET WALLS AND SURROUNDING MATERIALS AS
08 PROVIDE HANDS-FREE FALL PROTECTION REQUIRED BY ROOF MEMBRANE SYSTEM
SYSTEM WITH DAVITS 7" / 12" 7" / 12" MANUFACTURER'S WARRANTY.
M. AT CONTRACTOR'S OPTION, REINSTALL EXISTING GRAVEL
09 NEW ROOF HATCH A-202 BALLAST IF TYPE AND SIZE IS APPROPRIATE, AND IF REUSE
D3
10 EXTEND ROOF MEMBRANE OVER EXISTING 01 A-322 IS ALLOWED UNDER REQUIRED WARRANTY. DO NOT STORE
09
PARAPET D2 BALLAST IN A MANNER THAT COULD CAUSE DAMAGE TO
2
EXISTING STRUCTURE. PROPERLY DISPOSE OF UNUSED
1/4" : 1'-0"

1/4" : 1'-0"
7" / 12"
7" / 12"
A2 D6 BALLAST OFF-SITE.
A-301 A-322 N. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE
02
SUSPECTED OR DISCOVERED TO CONTAIN ASBESTOS OR
OTHER HAZARDOUS MATERIALS, STOP DEMOLITION AND
1/2" : 1'-0" 1/2" : 1'-0" 1/2" : 1'-0" NOTIFY OWNER AND ARCHITECT IMMEDIATELY.
(VIF) 02(VIF) D.S. 02 (VIF) O. VERIFY SIZE, LOCATION AND NUMBER OF EXISTING ROOF
1/2" : 1'-0" PENETRATIONS INCLUDING VENTS, PIPES, CURBS, ROOF
7
6 (VIF) DRAINS, CONDUITS, ETC. PROVIDE NEW FLASHING AND
SEAL EXISTING PENETRATIONS WHETHER OR NOT
INDICATED ON THE DRAWINGS.
1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
A6 P. COMPLETE WORK ABOVE ROOF, SUCH AS MASONRY WALL
A-350
REPAIR, WELDING, REPOINTING, ETC., PRIOR TO STARTING

1/4" : 1'-0"
RE-ROOFING WORK. SEAL | DATE 04/01/21
Q. RAISE EXISTING ROOF CURBS AND PROVIDE ADDITIONAL
BLOCKING FOR FANS, VENTS, INTAKES AND MECHANICAL
EQUIPMENT AS REQUIRED BY NEW ROOF SYSTEM AND
INSULATION THICKNESS.
R. RAISE EXISTING ROOF DRAINS, OVERFLOW DRAINS AND
SCUPPER OPENINGS AS REQUIRED BY NEW ROOF SYSTEM

1/4" : 1'-0"

1/4" : 1'-0"
AND INSULATION THICKNESS. EXTEND DRAIN PIPING AND
D.S.
REINSULATE AS REQUIRED.
S. PROVIDE NEW GRAVEL STOP AT EXTERIOR FASCIA
1/4" : 1'-0"

1/4" : 1'-0"
CONDITIONS AS REQUIRED BY NEW ROOF SYSTEM AND
INSULATION THICKNESS.
T. REMOVE EXISTING CAULKING AND PROVIDE NEW SEALANT
AT EXISTING FLASHING TO REMAIN.
1/2" : 1'-0" U. THE EXISTING ROOF SYSTEM MEMBRANE IS REPORTED TO
1/2" : 1'-0" 06 06 1/2" : 1'-0" 1/2" : 1'-0"
(VIF) BE ▐►FIRESTONE◄▌▐►CARLISLE] ▐►GOODYEAR◄▌
(VIF) (VIF) (VIF)
▐►OTHER◄▌AND IS STILL UNDER WARRANTY. WORK ON SHEET ISSUE
EXISTING ROOF AND CONNECTIONS TO EXISTING 1 Construction Documents 04/01/21
07 MEMBRANE SHALL BE PERFORMED AS REQUIRED TO
07 01
TYP. MAINTAIN CURRENT WARRANTY.
1/4" : 1'-0"

TYP. V. VERIFY AND MAINTAIN EXISTING ROOF SLOPES AND


08 DRAINAGE PATTERNS UNLESS OTHERWISE INDICATED.
D.S. TEST FOR AND CORRECT ANY PONDING CONDITIONS.
TYP.
PROVIDE SMOOTH TRANSITIONS BETWEEN NEW ROOFING
05 08 05 AND EXISTING FEATURES AS DETAILED OR AS REQUIRED BY
TYP. TYP. A-202 TYP. CONDITIONS.
E1 W. RESTORE ROOF TO A WEATHERTIGHT CONDITION AT THE
D4 A-321 CONCLUSION OF EACH DAY'S ROOF REMOVAL AND RE-
02
4 ROOFING ACTIVITIES.
X. REPAIR AND REPLACE EXISTING ROOFING OR STRUCTURE
DAMAGED BY IMPROPER STORAGE, CONSTRUCTION
12"

01 ACTIVITIES, OR LACK OF ADEQUATE TEMPORARY


PROTECTION. THIS ALSO INCLUDES INTERIOR DAMAGE TO
2 1/2" /

E5
3" / 12"
5
A-321 FINISHES, EQUIPMENT, FURNISHINGS, ETC., RESULTING
01 FROM LEAKS.
A-202
D3 Y. EXISTING WOOD BLOCKING SHALL REMAIN UNLESS
D.S. D.S. CONDITIONS REQUIRE REPLACEMENT OR UNLESS NOTED
OTHERWISE. NEW BLOCKING SHALL BE PRESERVATIVE-
TREATED WOOD.
Z. CAP FASTENERS THAT PENETRATE ROOF DECK IN AREAS
FRAMED OVERBUILD NOT CONCEALED BY CEILINGS WITH WIRE NUTS OR OTHER
ROOF CRICKET. MEANS ACCEPTABLE TO ARCHITECT UNLESS OTHERWISE
VERTICAL END OF INDICATED. AREAS SUCH AS JANITOR CLOSETS, STORAGE
CENTRAL MONITOR ROOMS, MECHANICAL AND ELECTRICAL EQUIPMENT
CLAD IN METAL PANEL. ROOMS, ETC., ARE EXEMPT FROM THIS REQUIREMENT
NORTH AND SOUTH UNLESS OTHERWISE INDICATED.
ENDS SIM. AA. REFER TO MECHANICAL DRAWINGS TO COORDINATE ROOF
CONDUCTOR LOCATIONS.

T
T
ALTERNATE: SHINGLE ROOF REPLACEMENT

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

ROOF PLAN -
C2
A-301
OVERALL
4/1/2021 11:43:18 AM

A5 ROOF PLAN SHEET NUMBER

A-105
A-105
1/16" = 1'-0"
RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
6.9 5.9 5.5 5.1 4.1 3.1 2.1
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240

1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
317-872-8400
N7 N6 N5 N4 1'-7 1/2"
A-202 B1 A1 A-202
L L Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
6.9 5.9 5.5 5.1 4.1 1'-7 1/2"
Indianapolis, Indiana 46204
317-634-4672

D D4 D
A-350
3"

D1
A-350
A-202
N7 N6 N5 N4

1/4" : 1'-0"
D2
M D3 M
A-322
A1 A-502 A5
2

7" / 12"
7" / 12"

1/4" : 1'-0"

1/4" : 1'-0"
8'-1 1/2"
8'-1 1/2"
A2 D6
E E A-301 A-322
1/4" : 1'-0"

1/2" : 1'-0" 1/2" : 1'-0"


F7
(VIF) (VIF)
A-540 13'-10 1/2" 13'-10 1/2"
1'-7 1/2"

N 1/2" : 1'-0" 1/2" : 1'-0" 1/2" : 1'-0" N


1/4" : 1'-0"

8 (VIF) (VIF) (VIF)


A-202
1/4" : 1'-0"

7
6
D1
20'-0"
F F
20'-0"
3
F
3 G

1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
1/4" : 1'-0"

E
2
7" / 12"
10'-1 1/4"

A6
A-322 O O D
A5
A-301
C
E6
A-351 1'-7 1/2"
A3 B 1
G A-322 G
A
1/2" : 1'-0" 7'-10" 1/2" : 1'-0"
(VIF) (VIF)
E4
A-351
KEY PLAN

P P SEAL | DATE 04/01/21

7'-5 3/4" 7'-5 3/4"


1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
H H

A3
A-321 Q 1/2" : 1'-0" 1/2" : 1'-0" 1/2" : 1'-0" Q
(VIF) (VIF) (VIF) SHEET ISSUE
1 Construction Documents 04/01/21

J J
1/4" : 1'-0"

1/4" : 1'-0"

1/4" : 1'-0"
1/4" : 1'-0"

1/4" : 1'-0"

R R

A-202

D4
K 1/2" : 1'-0" 1/2" : 1'-0" K
(VIF) (VIF)
E1
A-321
4

S S
46'-7 1/4"
1/4" : 1'-0"

1/4" : 1'-0"

14'-2 3/16"
1'-7 1/2" E5
A-202 A-202 A-321
B1 A1
L L S7 S6 S5 S4 S3 S2 COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
A-202 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
D3 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

1'-7 1/2" PROJECT NO. 19010.000


D4 SHEET TITLE
T A-350 T
SKYLIGHT PLAN
6.9 5.9 5.5 5.1 4.1 3.1 2.1
6.9 5.9 5.5
C2 5.1 4.1
4/1/2021 11:43:24 AM

A-301

S7 S6 C2 S5 S4 S3 S2
A-301 SHEET NUMBER

SKYLIGHT PLAN AREA 2 SKYLIGHT PLAN AREA 1


2
A-105.1
1/8" = 1'-0"
1
A-105.1
1/8" = 1'-0" A-105.1
GENERAL CEILING PLAN NOTES

A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.

RHIT MOENCH
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
RENOVATION
FINISHES.
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO 5500 Wabash Avenue
5.9 5.5 5.1 4.1 3.1 2.1 1.2 ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
REMAIN..
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
Terre Haute, Indiana
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED 47803
TO BE SHOWN IN THE PLANS AND INSTALLED
PAINT NEW F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING Owner
ACT-01 ACT-01 DUCTWORK TO CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID
MATCH EXISTING ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY Rose-Hulman Institute of Technology
7'-1" A.F.F. 7'-8" A.F.F.
STRUCTURE. CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH 5500 Wabash Avenue
GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN. Terre Haute, Indiana 47803
G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, 812-877-1511
GWB EX
SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
7'-1" A.F.F.
INDICATED.
H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
GWB EX ROBOTICS I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
7'-1 1/2" A.F.F. WORKROOM/STORAGE WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
M M
DL207A CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
ACT-01 ACT-01 INDICATED ON THE DRAWINGS.
7'-1 1/2" A.F.F. 7'-8" A.F.F. J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
MATERIALS
LAB REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
CL207
STARTING WORK.
STAIR ACT-01 K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
A2 8'-10" A.F.F. Architect
A-301 CL211 PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER
LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS. RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
21 CEILING LEGEND 317-633-4040
CUSTODIAL
STORAGE
STORAGE
N CL202B ACT-01 N CEILING TAG
CL212 Structural Engineer
7'-8" A.F.F.
CEILING TYPE Fink Roberts & Petrie, Inc.
XXX-01
10'-10" A.F.F. 9449 Priority Way W Dr #200
CEILING HEIGHT
CUSTODIAL (ABOVE FINISH FLOOR) Indianapolis, Indiana 46240
SERVICES 317-872-8400
CL202

25 25 SPOT ELEVATION MARKER


Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD 732 N Capitol Avenue
OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON Indianapolis, Indiana 46204
O O PLAN 317-634-4672

25 25 25
WORK
OFFICE INSTRUMENT SHOP
CUSTODIAL CL203 STORAGE CL206
EXPOSED STRUCTURE TO REMAIN AS-
STORAGE CL205 IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
CL202A DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
ACT-01 ACT-01 ACT-01 BE PREPPED AND DRYFALL PAINTED
8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. TO MATCH EXISTING EXPOSED
STRUCTURE WHERE APPLICABLE.
U.N.O. EXISTING LIGHTING TO BE
REUSED, BUT MAY NEED TO BE
RELOCATED DURING INSTALLATION OF
P P NEW HVAC AND DRYFALL PAINTING.

EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL


PLANK CLOUD

AREA N.I.C.

Q Q

CEILING PLAN NOTES


F
01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG 3 G
BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
MATCH EXISTING BUIDLING STANDARD.
E
2
02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE D
ORIGINAL CONSTRUCTION AND LIGHTING.
03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS C
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED.
R R
04
B 1
05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME A
INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE KEY PLAN
REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
5.9 5.5
C2 5.1 4.1 3.1 2.1 1.2 SEAL | DATE 04/01/21
A-301
09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
2.
11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
. PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
1 FIRST LEVEL RCP QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
A-131.1
1/8" = 1'-0" FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
NEW RECESSED LIGHTING AS SHOWN.
12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
LIGHTING AS SHOWN IN ELECTRICAL PLANS. SHEET ISSUE
14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS. 1 Construction Documents 04/01/21
17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
AS REQUIRED.
18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
REMOVED.
19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
MITIGATE SOUND TRANSFER BETWEEN OFFICES.
21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
NEW TO MATCH EXISTING.
26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT
CEILING AND EXTENSION TO APPEAR SEAMLESS. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND
ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT PROJECT NO. 19010.000
CAFE. AS SHOWN IN ELECTRICAL DRAWINGS.. SHEET TITLE
31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER
BULKHEADS IN ADJACENT AREA. LOWER LEVEL 2
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF REFLECTED CEILING
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND
PLAN - AREA 1
4/1/2021 12:07:07 PM

COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
NEW 2X2 ACT CEILING.
33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG
CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING SHEET NUMBER
FLOORING FINISHES ON LEVEL ABOVE.
A-131.1
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 GENERAL CEILING PLAN NOTES
A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.

A5
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
RHIT MOENCH
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN

A
A-622

A
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
RENOVATION
FINISHES.
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO 5500 Wabash Avenue
ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
REMAIN..
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
Terre Haute, Indiana
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED 47803
TO BE SHOWN IN THE PLANS AND INSTALLED
F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING Owner
CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID
ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY Rose-Hulman Institute of Technology
CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH 5500 Wabash Avenue
GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN. Terre Haute, Indiana 47803
G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, 812-877-1511
B B SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
INDICATED.
H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
STORAGE WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
FL206 STORAGE ELECTRICAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
FL205 SWITCH INDICATED ON THE DRAWINGS.
GEAR J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
MECHANICAL REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
FL203
FL201 OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
STARTING WORK.
K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER
Architect
LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS. RATIO
C C 101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
CEILING LEGEND
MECHANICAL 1/8" = 1'-0" Structural Engineer
FL202
CEILING TAG Fink Roberts & Petrie, Inc.
CEILING TYPE 9449 Priority Way W Dr #200
XXX-01 Indianapolis, Indiana 46240
10'-10" A.F.F. CEILING HEIGHT 317-872-8400
CIRCULATION
9.8 8.9 7.9 - 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2 (ABOVE FINISH FLOOR)

Mechanical / Electrical Engineer


D D SPOT ELEVATION MARKER
R.E. Dimond & Associates, Inc.
CIRCULATION
732 N Capitol Avenue
-
Indianapolis, Indiana 46204
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD 317-634-4672
OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON
CIRCULATION PLAN
-

DW
MAIL DIST.
ELEVATOR CENTER DELIVERY PAINT NEW
MECHANICAL ANNEX
ELEV 1 CAGE DUCTWORK TO
EL203 EL204
- - MATCH EXISTING
ACT-01 ACT-01 STRUCTURE EXPOSED STRUCTURE TO REMAIN AS-
ACT-01 7'-3" A.F.F. 8'-5" A.F.F. IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
8'-3" A.F.F. DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
E E
BE PREPPED AND DRYFALL PAINTED
FAB. LAB FAB. LAB TO MATCH EXISTING EXPOSED
STOCK STOCK PAINT NEW STRUCTURE WHERE APPLICABLE.
OFFICE STORAGE STORAGE DUCTWORK TO U.N.O. EXISTING LIGHTING TO BE
EL202A CL208 CL208 MATCH EXISTING REUSED, BUT MAY NEED TO BE
STRUCTURE RELOCATED DURING INSTALLATION OF
ACT-01
NEW HVAC AND DRYFALL PAINTING.
8'-0" A.F.F.

EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL


PLANK CLOUD

F MACHINE F
TOOL LAB FABRICATION
II LAB AREA N.I.C.
EL202 EL207
CIRCULATION
EL211 TOOL
ROOM
STAIR EL205
- GWB EX CEILING PLAN NOTES
A5 7'-8" A.F.F.
ACT-01 F
A-301
ACT-01
8'-3" A.F.F. 8'-0" A.F.F.
EXP
PAINT NEW
DUCTWORK TO
3 G
18 01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
9'-0" A.F.F. MATCH EXISTING
STRUCTURE BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
E
2
MATCH EXISTING BUIDLING STANDARD. D
G GWB EX G
7'-2" A.F.F. 02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE
ORIGINAL CONSTRUCTION AND LIGHTING. C
03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS
ACT-01
8'-10" A.F.F.
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED. B 1
04
PAINT NEW A
DUCTWORK TO 05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME
MATCH EXISTING INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
STRUCTURE
08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS KEY PLAN
ACT-01 ACT-01 TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE
7'-6" A.F.F. 7'-8" A.F.F. MACHINE
TOOL REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
SEAL | DATE 04/01/21
H ACT-01 SHOP H 09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
8'-0" A.F.F. DL202
INSTRUCTIONAL NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
MENS R.R. TECHNOLOGY I.T. 2.
DL203 DL204 EQUIP./OFFICE
DL204A 11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
. PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
NEW RECESSED LIGHTING AS SHOWN.
12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
J J
MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
LIGHTING AS SHOWN IN ELECTRICAL PLANS. SHEET ISSUE
ACT-01 1 Construction Documents 04/01/21
MANAGER
7'-10" A.F.F. 14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS.
OFFICE OFFICE
DL204B DL205 17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
ACT-01 COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
7'-6" A.F.F.
PAINT NEW AS REQUIRED.
ACT-01 CIRCULATION DUCTWORK TO 18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
7'-8" A.F.F. - MATCH EXISTING
WORK
STRUCTURE INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
SHOP OFFICE AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
DL206A DL206
REMOVED.
ACT-01
7'-8" A.F.F. MANUFACTURING 19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
K LAB K MITIGATE SOUND TRANSFER BETWEEN OFFICES.
DL201
21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
ACT-01
8'-10" A.F.F. CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
ACT-01 WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
7'-8" A.F.F.
CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
AREA 2
AREA 2 23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
ROBOTICS ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
CLASSROOM
L DL207 L 25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
AREA 1
AREA 1 WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
GWB EX
NEW TO MATCH EXISTING.
7'-1" A.F.F. 26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
PAINT NEW
ACT-01 ACT-01 DUCTWORK TO 27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
7'-1" A.F.F. 7'-8" A.F.F. MATCH EXISTING 29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT
STRUCTURE. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
CEILING AND EXTENSION TO APPEAR SEAMLESS. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL

GWB EX 30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

7'-1" A.F.F. PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND PROJECT NO. 19010.000
ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT
GWB EX ROBOTICS CAFE. AS SHOWN IN ELECTRICAL DRAWINGS.. SHEET TITLE
7'-1 1/2" A.F.F. WORKROOM/STORAGE
DL207A 31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER
BULKHEADS IN ADJACENT AREA.
LOWER LEVEL 2
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG REFLECTED CEILING
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND PLAN - AREA 2
4/1/2021 12:07:11 PM

9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
NEW 2X2 ACT CEILING.
1 FIRST LEVEL RCP 33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG SHEET NUMBER
A-131.2
1/8" = 1'-0" CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING
FLOORING FINISHES ON LEVEL ABOVE.
A-131.2
GENERAL CEILING PLAN NOTES
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.

RHIT MOENCH
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN

OFFICE
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
RENOVATION
ACT-01 GWB EX
GWB EX
7'-6" A.F.F.
7'-6 1/2" A.F.F. 7'-6 1/2" A.F.F.
CL109 FINISHES.
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO 5500 Wabash Avenue
B1 ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
ACT-01
7'-11" A.F.F.
WD BEAM
ACT-01
7'-11" A.F.F.
ACT-01
8'-0" A.F.F.
18 18 A-540 1'-6"
ACT-01
OPEN TO
LEVEL 1
REMAIN..
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
Terre Haute, Indiana
WD BEAM
7'-9" A.F.F. WD BEAM
7'-9" A.F.F.
7'-9" A.F.F. 1'-0"
01
GWB EX
7'-9" A.F.F.
B1
A-540
01
18 7'-10" A.F.F. 2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED 47803
M 01 M TO BE SHOWN IN THE PLANS AND INSTALLED
21 F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING Owner
WD BEAM WD BEAM ACT-01 B1 CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID
7'-9" A.F.F. 7'-9" A.F.F. 8'-0" A.F.F. GWB EX
ACT-01 EXP A-540
21 ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY Rose-Hulman Institute of Technology
7'-6" A.F.F. 7'-9" A.F.F.
7'-11" A.F.F. GWB EX
H BAR
CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH 5500 Wabash Avenue
M.T.F. 8'-0" A.F.F.
NON-LINEAR GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN. Terre Haute, Indiana 47803
MEASUREMENT STAIR EL108
OPTICS CONFERENCE G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, 812-877-1511
LAB CIRCULATION -
A2 LAB ROOM SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
A-301
CL114 - INDICATED.
CL115 CL116 OPEN TO
ACT-01 LEVEL 1 H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
7'-11" A.F.F. I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
GWB EX GWB EX B1 GWB EX GWB EX GWB EX CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
GWB EX EXP GWB EX 7'-6" A.F.F. 7'-6" A.F.F. 7'-6" A.F.F.
7'-6" A.F.F. 7'-6" A.F.F. A-540 INDICATED ON THE DRAWINGS.
7'-6" A.F.F. 7'-9" A.F.F. 7'-6 1/2" A.F.F.
ACT-03 21 J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
N 7'-11" A.F.F. 01 N REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
18 B1 OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
18 01 18 ACT-01 ACT-01
1'-0" 1'-0" A-540 01 ACT-01 STARTING WORK.
GWB EX B1 ACT-01 7'-11" A.F.F. 7'-11" A.F.F.
7'-6" A.F.F. 1'-6" 7'-11" A.F.F. K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
A-540 7'-9" A.F.F. B1 Architect
PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER
A-540
GWB EX 01 ACT-01 ACT-01 ADMIN
LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS. RATIO
7'-7" A.F.F. GWB EX 7'-6 1/2" A.F.F. 7'-11" A.F.F. 101 South Pennsylvania Street
OFFICE OFFICE OFFICE
7'-9" A.F.F. Indianapolis, Indiana 46204
CL108 CL106 CL105
EXP OFFICE CEILING LEGEND 317-633-4040
9'-8" A.F.F. CL107
ACT-03
7'-11" A.F.F. WD BEAM CEILING TAG Structural Engineer
EXP 7'-9" A.F.F.
7'-9" A.F.F. CEILING TYPE Fink Roberts & Petrie, Inc.
WD BEAM XXX-01
O 21 21 21 21 O 10'-10" A.F.F.
9449 Priority Way W Dr #200
7'-9" A.F.F. CEILING HEIGHT
PHYSICS GWB EX GWB EX WD BEAM Indianapolis, Indiana 46240
21 7'-9" A.F.F. (ABOVE FINISH FLOOR) 317-872-8400
LAB 3 7'-1 1/2" A.F.F. 7'-1 1/2" A.F.F.
CL117 ACT-01
CIRCULATION 7'-11" A.F.F. ACT-01
CLASSROOM - 7'-11" A.F.F. SPOT ELEVATION MARKER
CL119 Mechanical / Electrical Engineer
ACT-01 OFFICE
7'-7" A.F.F. EXP ELECTRICAL E.I.T. STORAGE R.E. Dimond & Associates, Inc.
ROOM CL102A CL102B CL104
9'-8" A.F.F.
CL101 48 SF 107 SF ACT-01 OPTICAL 184 SF 732 N Capitol Avenue
EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD
GWB EX 81 SF
EXP EXP 7'-11" A.F.F. COMMUNICATIONS Indianapolis, Indiana 46204
LAB OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON
7'-6" A.F.F. 10'-0" A.F.F. 10'-0" A.F.F. 317-634-4672
EXP CL103 PLAN
10'-0" A.F.F.

P P
ACT-01
8'-0" A.F.F. EXPOSED STRUCTURE TO REMAIN AS-
IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
ACT-01 OFFICE DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
ACT-01
8'-0" A.F.F. EXP 7'-11" A.F.F. BL103 BE PREPPED AND DRYFALL PAINTED
ACT-01 ENGINEERING OFFICE TO MATCH EXISTING EXPOSED
9'-8" A.F.F. ACT-01
7'-10" A.F.F. PHYSICS STRUCTURE WHERE APPLICABLE.
7'-11" A.F.F. ACT-01 ACT-01 BL102
LAB 1 U.N.O. EXISTING LIGHTING TO BE
MATERIALS 7'-11" A.F.F. 7'-11" A.F.F.
BL110 REUSED, BUT MAY NEED TO BE
PROCESSING
ACT-01 RELOCATED DURING INSTALLATION OF
LAB
7'-11" A.F.F. NEW HVAC AND DRYFALL PAINTING.
BL112 GWB EX GWB EX
7'-6" A.F.F. 7'-6" A.F.F.
PHYSICS GWB EX GWB EX
Q LAB 1 7'-7" A.F.F. 7'-6" A.F.F. Q
EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL
BL113 OFFICE
GWB EX GWB EX GWB-X1 ACT-01 PLANK CLOUD
ACT-01 7'-6" A.F.F. BL104 8'-0" A.F.F.
7'-7" A.F.F. 7'-6" A.F.F.
8'-0" A.F.F.
PHYSICS
STOCK OFFICE
ACT-01 ACT-01 ACT-01
7'-10" A.F.F. ROOM BL109 ACT-01 OFFICE AREA N.I.C.
7'-11" A.F.F. BL108 8'-0" A.F.F. 7'-11" A.F.F. BL101
ACT-01
GWB EX 7'-11" A.F.F. OFFICE
18 EXP
7'-9" A.F.F. 9'-8" A.F.F. BL105
GWB EX GWB EX
GWB EX 7'-6" A.F.F.
CIRCULATION 7'-6" A.F.F.
7'-6" A.F.F.
-
R GWB EX 21 R CEILING PLAN NOTES
7'-7" A.F.F.
F
GWB EX
7'-9" A.F.F.
18 GWB EX
7'-6" A.F.F.
GWB EX
7'-6" A.F.F.
GWB EX
7'-6" A.F.F. GWB EX 3 G
01 7'-6" A.F.F. 01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
ACT-01
7'-9" A.F.F.
B1
A-540 BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
E
2
MATCH EXISTING BUIDLING STANDARD.

7'-11" A.F.F.
ACT-01 ACT-01 D
MACHINE

ACT-01
ACT-01 8'-0" A.F.F. 8'-0" A.F.F.
ELECTRICAL SHOP OFFICE 02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE
7'-10" A.F.F. ROOM GWB EX EXP
7'-9" A.F.F. 9'-8" A.F.F. BL107
OFFICE
BL100 ORIGINAL CONSTRUCTION AND LIGHTING. C
BL115
BL106 03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS
EXP
10'-0" A.F.F.
GWB EX
7'-2" A.F.F.
GWB EX
7'-6" A.F.F.
GWB EX
7'-6" A.F.F.
GWB EX ACT-01
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED. B 1
PHYSICS
7'-6" A.F.F. 8'-0" A.F.F. 04
LAB 2 21 A
S 21 S 05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME
BL114 CIRCULATION ACT-01
GWB EX - 01 INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
ACT-01 B1 8'-0" A.F.F.
7'-7" A.F.F. ELEV 2 8'-8" A.F.F. 21 08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
21 A-540 KEY PLAN
- TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE
CUSTODIAL 1'-6" 21
STORAGE OPEN TO LEVEL REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
ACT-01 BL116 2 SKYLIGHT- SEAL | DATE 04/01/21
7'-10" A.F.F. ACT-01 ACT-01 ACT-01
09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
S10 S9 S8 S7 S6 21 7'-8" A.F.F. S5 7'-8" A.F.F. S4 S3 GWB EX S2 S1
EXP
7'-8" A.F.F. 8'-0" A.F.F. NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
8'-8" A.F.F. ELEVATOR OFFICE OFFICE OFFICE 2.
MECHANICAL AL104 AL103 AL102 11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
21
BL117 . PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
T T
FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
GWB EX NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
8'-0" A.F.F. ACT-01
8'-8" A.F.F. NEW RECESSED LIGHTING AS SHOWN.
STORAGE
ART AL101A
CURATOR 12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 AL101 2.1 1.2 MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
LIGHTING AS SHOWN IN ELECTRICAL PLANS. SHEET ISSUE
1 Construction Documents 04/01/21
14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS.
WATER ROOM 17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
AL106
50 SF COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
AS REQUIRED.
U U 18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
EXP
10'-0" A.F.F. INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
REMOVED.
19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
MITIGATE SOUND TRANSFER BETWEEN OFFICES.
21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
V V WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
NEW TO MATCH EXISTING.
26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
CEILING AND EXTENSION TO APPEAR SEAMLESS. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
W W DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND PROJECT NO. 19010.000
ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT
CAFE. AS SHOWN IN ELECTRICAL DRAWINGS.. SHEET TITLE

31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER


BULKHEADS IN ADJACENT AREA.
LOWER LEVEL 1
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG REFLECTED CEILING
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF
S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND PLAN - AREA 1
4/1/2021 12:07:17 PM

COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
NEW 2X2 ACT CEILING.
1 LOWER LEVEL 1 - AREA 1 33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG SHEET NUMBER
A-132.1
1/8" = 1'-0" CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING
FLOORING FINISHES ON LEVEL ABOVE.
A-132.1
GENERAL CEILING PLAN NOTES
A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.

N10 N9 N8 N7 N6 N5 N4 N3 N2 N1
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
RHIT MOENCH
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
RENOVATION
FINISHES.
TYP.
A7 C5
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO
ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
5500 Wabash Avenue
A
TYP.
A-622 A-622
TYP.
A
REMAIN..
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
Terre Haute, Indiana
WT-01
WT-01 WT-01 WT-01 WT-01 EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED
TO BE SHOWN IN THE PLANS AND INSTALLED
47803
F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING
CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID Owner
ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY
FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH
Rose-Hulman Institute of Technology
WT-01 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN. 5500 Wabash Avenue
26 FL115 FL113 FL111 FL109 FL107 FL105 FL103 FL101 G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, Terre Haute, Indiana 47803
19
26 19 26 19 26 19 26 19 26 26 19 19 26 26 SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE 812-877-1511
ACT-01 19 19 INDICATED.
8'-0" A.F.F. ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
B B INDICATED ON THE DRAWINGS.
J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
CONC-01
D4 D4 REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
7'-4" A.F.F. 18
A-540 18 A-540 CONC-01 OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
26 7'-4" A.F.F. STARTING WORK.
ACT-01 19
8'-0" A.F.F. 18 K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
19 26 18 PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER
26
FACULTY 26 19 26 Architect
19 26 FACULTY LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS.
19 19
FACULTY COLLISION
FACULTY OFFICE FACULTY
RATIO
WT-01 19 ACT-01 FL108 FL104 ACT-01
26 CONC-01
OFFICE OFFICE OFFICE 101 South Pennsylvania Street
ACT-01 FL112 8'-0" A.F.F. FL106 8'-0" A.F.F. Indianapolis, Indiana 46204
FACULTY 7'-4" A.F.F. ACT-01 FL102
8'-0" A.F.F. CONC-01 317-633-4040
OFFICE
FL114
ACT-01 7'-4" A.F.F. ACT-01 8'-0" A.F.F. ACT-01 CEILING LEGEND
8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F.

C C Structural Engineer
CEILING TAG
ACT-01 ACT-01 ACT-01 D6 ACT-01 D6
Fink Roberts & Petrie, Inc.
GWB-X1 D6 8'-0" A.F.F. D6 8'-0" A.F.F. 8'-0" A.F.F. A-540 CEILING TYPE
7'-0" A.F.F. A-540 A-540
8'-0" A.F.F. A-540 XXX-01 9449 Priority Way W Dr #200
10'-10" A.F.F. CEILING HEIGHT Indianapolis, Indiana 46240
ACT-01 CONC-01
7'-1" A.F.F. 7'-4" A.F.F. (ABOVE FINISH FLOOR) 317-872-8400

11 11 11
11 EXP SPOT ELEVATION MARKER Mechanical / Electrical Engineer
9'-0" A.F.F.
R.E. Dimond & Associates, Inc.
GWB-X1 GWB-X2 732 N Capitol Avenue
9.8 8.9 7.9 8'-3" A.F.F. 6.9 7'-10" A.F.F.
5.9 5.5 5.1 4.1 3.1 2.1 1.2
ACT-01 EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD Indianapolis, Indiana 46204
3'-3" MIN.
7'-10" A.F.F. OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON 317-634-4672
PLAN
D D
GWB-X1
6"

GWB EX 7'-2" A.F.F. PT-01 18 ALIGN 31


05 KITCHEN F3 CORRIDOR
7'-1 1/2" A.F.F. GWB EX
EQ.

D1 18 EL125 7'-2" A.F.F. A-540 -


N10 N9 18 N8 N7 N6 N5 N4 N3 N2 N1
PT-01 A-540
ACT-02 GWB-X1
261 SF
6" 23 EXPOSED STRUCTURE TO REMAIN AS-
5'-0"

5'-0"

ALIGN 7'-11" A.F.F. 7'-9" A.F.F. BUILDING STANDARD 2'X2' GRID AND
D1 PT-01 F5 IS UNLESS NOTED OTHERWISE. NEW
A-540 GWB-X1 18 A-540 DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
8'-3" A.F.F. HOUSEKEEPING BE PREPPED AND DRYFALL PAINTED
A4 18 EQUIPMENT TO MATCH EXISTING EXPOSED
ACT-02
5'-0"
5'-0"

MOENCH A-540 ACT-02 EXP ELEV 1 ROOM STRUCTURE WHERE APPLICABLE.


7'-11" A.F.F. 18 7'-11" A.F.F.
CAFE 10'-0" A.F.F. - EL102 U.N.O. EXISTING LIGHTING TO BE
ELXXX 84 SF REUSED, BUT MAY NEED TO BE
EQ.

23 RELOCATED DURING INSTALLATION OF


PT-05 18 STORAGE NEW HVAC AND DRYFALL PAINTING.
E 18 E

2'-10 1/4"
EL126 ACT-01
B4 B6 PT-05 1'-6"
GWB EX 7'-1" A.F.F.
A-540 A-540 ALIGN GWB-X1
7'-6 1/2" A.F.F.
7'-6 1/2" A.F.F. 31 EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL
GWB EX
A6 EXP MAIL SORT PLANK CLOUD
ACT-01 F3 7'-0" A.F.F. ACT-01
A-540 31 10'-0" A.F.F. EL103
PT-01 8'-4" A.F.F. A2 A-540 7'-6" A.F.F.
LOUNGE A-540 GWB-X1
EL112 GWB-X1 18 18 7'-9" A.F.F.
8'-3" A.F.F. GWB-X1
8'-3" A.F.F.
AREA N.I.C.
B2 GWB-X1 GWB EX ACT-01
A-540 ACT-01 7'-0" A.F.F. 7'-9" A.F.F. 7'-6" A.F.F.
ALIGN 31 27
8'-4" A.F.F. 21
18
F PT-05 GWB EX PT-01 F
OPEN TO 7'-6 1/2" A.F.F.
LEVEL 2 27 CEILING PLAN NOTES
A2 18
1'-6" ALIGN A-540
1'-6"
18 F
2'-0" GWB-X1
23
01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
3 G
GWB-X1
8'-3" A.F.F. 18 GWB-X1
18
ACT-01
7'-9" A.F.F.
F3
WOMENS R.R.
EL105
ACT-01
7'-7" A.F.F.
BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
MATCH EXISTING BUIDLING STANDARD.
E
2
PT-01 8'-3" A.F.F.
A5 8'-4" A.F.F. A-540 D
A-301
ACT-01 MENS R.R.
02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE
31 18 7'-7" A.F.F. EL104 ORIGINAL CONSTRUCTION AND LIGHTING.
ACT-01 C
8'-4" A.F.F. A2 31 03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS
A-540
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED.
G G 04
B 1
ACT-01 ACT-01 05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME A
7'-9" A.F.F. ACT-01 7'-11" A.F.F. INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
7'-10" A.F.F. ACT-01 ACT-01
7'-10" A.F.F. 7'-10" A.F.F. EXPOSED PAINTED SEMICONDUCTOR 08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
OFFICE WOOD DECK ACT-01 OPTICS LAB KEY PLAN
OFFICE DL110D OFFICE OFFICE OFFICE 7'-11" A.F.F. TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE
DL108
DL110C DL110E DL110F DL110G REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
OFFICE SEAL | DATE 04/01/21
DL107 09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
ACT-01
2.
ACT-01
7'-10" A.F.F.
7'-8" A.F.F. WD BEAM 21 11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
7'-9" A.F.F. ACT-01 . PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
H H
7'-9" A.F.F. GWB-X1 QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
WD BEAM GWB EX
WD BEAM 7'-9" A.F.F. 7'-6" A.F.F. FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
7'-3" A.F.F.
7'-9" A.F.F.
NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
OFFICE ADMIN OFFICE
OFFICE DL110A DL110 NEW RECESSED LIGHTING AS SHOWN.
ACT-01
DL110B 7'-11" A.F.F. 12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
ACT-01 ACT-01 ACT-01 NUCLEAR OFFICE MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
7'-11" A.F.F. ACT-01 7'-9" A.F.F. 7'-10" A.F.F. PHYSICS LAB DL106 LIGHTING AS SHOWN IN ELECTRICAL PLANS. SHEET ISSUE
7'-10" A.F.F. DL105
ACT-01 14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS. 1 Construction Documents 04/01/21
8'-0" A.F.F. ACT-01
GWB EX 7'-11" A.F.F.
GWB EX 17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
7'-6" A.F.F. 7'-6" A.F.F.
COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
J GWB EX GWB EX J
7'-6" A.F.F. ACT-01 7'-9" A.F.F. AS REQUIRED.
GWB EX
7'-11" A.F.F. 7'-6" A.F.F. 18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
OPTICAL GWB EX
ENGINEERING 7'-6" A.F.F. INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
LAB 3 OPTICAL AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
ACT-01 ACT-01 EXPOSED PAINTED METROLOGY
DL115 8'-0" A.F.F. 8'-0" A.F.F. ACT-01 REMOVED.
WOOD DECK LAB
7'-11" A.F.F. OFFICE
DL104 19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
EXP DL103
ACT-01 10'-0" A.F.F. MITIGATE SOUND TRANSFER BETWEEN OFFICES.
7'-11" A.F.F. EXP
9'-8" A.F.F. 21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
GWB EX ACT-01
CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
WD BEAM 7'-3" A.F.F. 21 7'-11" A.F.F. WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
7'-9" A.F.F. 21
ACT-01 GWB EX ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
K 7'-3" A.F.F. K
7'-9" A.F.F. NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
WD BEAM
7'-9" A.F.F. ACT-01 WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
7'-9" A.F.F. ACT-01
7'-11" A.F.F. CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
EXP
OPTICAL
ACT-01 ACT-01
7'-9" A.F.F. 23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
ENGINEERING ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
ACT-01 7'-11" A.F.F. 7'-8" A.F.F.
LAB 1
7'-11" A.F.F. OFFICE
DL117 DARK ROOM CLASSROOM SENIOR
DL102
25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
G112 DL119 EXP DESIGN LAB
WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
9'-8" A.F.F. DL101
GWB EX ACT-01 NEW TO MATCH EXISTING.
GWB EX 7'-6" A.F.F. 7'-11" A.F.F. 26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
7'-6" A.F.F.
ACT-01
7'-11" A.F.F. 27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
GWB EX
L L
7'-6" A.F.F. EXP 29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT
OPTICAL CLASSROOM 7'-9" A.F.F. GWB EX GWB EX CEILING AND EXTENSION TO APPEAR SEAMLESS. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
GWB EX ENGINEERING
GWB EX 7'-6" A.F.F. 7'-6" A.F.F. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
7'-6" A.F.F. 7'-6" A.F.F. DL119 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
LAB 2 30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
ACOUSTICS
CL118 ACT-01
ACT-01 EXP PROJECTS ACT-01 PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND
8'-0" A.F.F. PROJECT NO. 19010.000
7'-8" A.F.F. 9'-8" A.F.F. LAB 7'-9" A.F.F. OFFICE ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT
GWB EX CL110 CL109 CAFE. AS SHOWN IN ELECTRICAL DRAWINGS.. SHEET TITLE
7'-6" A.F.F.
ACT-01
7'-11" A.F.F.
ACT-01
7'-11" A.F.F.
18 18
B1
A-540
31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER
BULKHEADS IN ADJACENT AREA. LOWER LEVEL 1
01
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF
REFLECTED CEILING
9.8 8.9 7.9 6.9 5.9 5.5
C2 5.1 4.1 3.1 2.1 1.2 RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND PLAN - AREA 2
4/1/2021 12:07:24 PM

A-301 COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
NEW 2X2 ACT CEILING.
1 LOWER LEVEL 1 - AREA 2 33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG
A-132.2 SHEET NUMBER
1/8" = 1'-0" CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING
FLOORING FINISHES ON LEVEL ABOVE.
A-132.2
GENERAL CEILING PLAN NOTES

A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.


B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
RHIT MOENCH
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
RENOVATION
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
FINISHES.
5500 Wabash Avenue
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO
ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
REMAIN..
Terre Haute, Indiana
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL 47803
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED
TO BE SHOWN IN THE PLANS AND INSTALLED Owner
F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING
CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID
Rose-Hulman Institute of Technology
ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY 5500 Wabash Avenue
CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH Terre Haute, Indiana 47803
GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN. 812-877-1511
G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS,
SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
INDICATED.
H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
INDICATED ON THE DRAWINGS.
J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
STARTING WORK. Architect
K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER RATIO
LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS. 101 South Pennsylvania Street
Indianapolis, Indiana 46204
CEILING LEGEND 317-633-4040

Structural Engineer
CEILING TAG
CLOSET Fink Roberts & Petrie, Inc.
G220A 17 CEILING TYPE
32 SF XXX-01 9449 Priority Way W Dr #200
10'-10" A.F.F. CEILING HEIGHT
Indianapolis, Indiana 46240
MENS R.R. 317-872-8400
G206 (ABOVE FINISH FLOOR)
165 SF

STUDY AREA SPOT ELEVATION MARKER Mechanical / Electrical Engineer


CLASSROOM G204 R.E. Dimond & Associates, Inc.
G203 299 SF
732 N Capitol Avenue
CLASSROOM CLASSROOM EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD Indianapolis, Indiana 46204
G222 G220 OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON 317-634-4672
938 SF 733 SF
PLAN
18
A7 WOMENS R.R.
A-351 G202
110 SF

ACT-01 EXPOSED STRUCTURE TO REMAIN AS-


9'-0" A.F.F. IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
BE PREPPED AND DRYFALL PAINTED
TO MATCH EXISTING EXPOSED
STRUCTURE WHERE APPLICABLE.
STAIR CIRCULATION ACT-01 U.N.O. EXISTING LIGHTING TO BE
- - 7'-1" A.F.F. REUSED, BUT MAY NEED TO BE
179 SF 1404 SF
GWB-X1
7'-0" A.F.F. RELOCATED DURING INSTALLATION OF
NEW HVAC AND DRYFALL PAINTING.

ACT-01
ACT-01 ACT-01 9'-0" A.F.F.
9'-0" A.F.F. 9'-0" A.F.F. EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL
PLANK CLOUD
18
STG.
G210A
STAIR
18 -
128 SF AREA N.I.C.

CLASSROOM CLASSROOM CLASSROOM


G221 G219 G208 18 STUDENT CEILING PLAN NOTES
858 SF 852 SF AREA
G210 F
01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
3 G

17
BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
E
2
MATCH EXISTING BUIDLING STANDARD.
D
02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE
ORIGINAL CONSTRUCTION AND LIGHTING.
C
03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS

04
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED. B 1
COOK 05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME A
GREENHOUSE INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
G219A
1266 SF 08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE KEY PLAN
REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
SEAL | DATE 04/01/21
09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
2.
11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
. PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
1 LOWER LEVEL 1 - AREA 3 FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
A-132.3
1/8" = 1'-0" NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
NEW RECESSED LIGHTING AS SHOWN.
12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
LIGHTING AS SHOWN IN ELECTRICAL PLANS. SHEET ISSUE
14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS. 1 Construction Documents 04/01/21
17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
AS REQUIRED.
18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
REMOVED.
19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
MITIGATE SOUND TRANSFER BETWEEN OFFICES.
21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
NEW TO MATCH EXISTING.
26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
CEILING AND EXTENSION TO APPEAR SEAMLESS. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND
ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT PROJECT NO. 19010.000
CAFE. AS SHOWN IN ELECTRICAL DRAWINGS.. SHEET TITLE
31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER
BULKHEADS IN ADJACENT AREA.
LOWER LEVEL 1
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF
REFLECTED CEILING
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND PLAN - AREA 3
4/1/2021 12:07:28 PM

COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
NEW 2X2 ACT CEILING.
33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG SHEET NUMBER
CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING
FLOORING FINISHES ON LEVEL ABOVE.
A-132.3
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
GENERAL CEILING PLAN NOTES
STORAGE
D115A OFFICE
A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.

CIRCULATION
D102
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
RHIT MOENCH
-
ACT-01
7'-1" A.F.F.
GWB-X1 GWB-X1
ACT-01
7'-10" A.F.F.
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
RENOVATION
7'-1" A.F.F. 7'-1" A.F.F.
L
EQUIPMENT
INSTRUMENT
ROOM
L REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
FINISHES. 5500 Wabash Avenue
C114 OFFICE D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO
STORAGE
C115A
WORKSHOP/STORAGE
C112
C110 ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
REMAIN..
Terre Haute, Indiana
ACT-01

21
7'-9" A.F.F.
EXP
ACT-01
7'-9" A.F.F.
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED
47803
9'-0" A.F.F. TO BE SHOWN IN THE PLANS AND INSTALLED
ACT-01 ACT-01 Owner
7'-2" A.F.F. 7'-9" A.F.F. F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING
CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID Rose-Hulman Institute of Technology
ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY 5500 Wabash Avenue
OFFICE CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH
OPEN TO LEVEL 2 MECHATRONICS Terre Haute, Indiana 47803
C109 GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN.
C111 812-877-1511
G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS,
M M SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
ACT-01 INDICATED.
DIGITAL B1 7'-9" A.F.F.
18 A-540 H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
ELECTRONIC I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
MICROCOMPUTER 01
ACT-01 WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
LABORATORY 7'-10" A.F.F. CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT

1'-0"
C115 ACT-01 25
7'-1 1/2" A.F.F. 1'-0" INDICATED ON THE DRAWINGS.
A2 OFFICE J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
B1 REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
A-301 A-540 GWB EX C108
7'-9" A.F.F. OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
CIRCULATION STARTING WORK.
21 Architect

1'-0"
01 - GWB EX ACT-01 K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
GWB EX 7'-1" A.F.F. 7'-9" A.F.F.
7'-9" A.F.F. 5589 SF PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER RATIO
LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS.
101 South Pennsylvania Street
Indianapolis, Indiana 46204
N ACT-01 GWB EX N 317-633-4040
8'-0" A.F.F. 7'-9 1/2" A.F.F.
18
01 CEILING LEGEND Structural Engineer
B1
A-540 Fink Roberts & Petrie, Inc.
OPEN TO LEVEL 2 ACT-01
25 CEILING TAG 9449 Priority Way W Dr #200
7'-1 1/2" A.F.F. ACT-01 ACT-01 25 25 25
7'-9" A.F.F. 7'-9" A.F.F. Indianapolis, Indiana 46240
CEILING TYPE
XXX-01 317-872-8400
21 ACT-01 10'-10" A.F.F. CEILING HEIGHT
OFFICE 7'-10" A.F.F.
OFFICE ACT-01 (ABOVE FINISH FLOOR)
DYNAMIC C118
C117 7'-10" A.F.F.
SYSTEMS AND GWB EX Mechanical / Electrical Engineer
CONTROLS GWB EX GWB EX 7'-9" A.F.F.
LABORATORY R.E. Dimond & Associates, Inc.
O 7'-2" A.F.F. 7'-2" A.F.F. O SPOT ELEVATION MARKER
C116 MAIL ROOM 732 N Capitol Avenue
WORKROOM / C104 Indianapolis, Indiana 46204
BREAKROOM 317-634-4672
OFFICE ADMIN 25
C103A ACT-01
C103 EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD
7'-10" A.F.F. OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON
ACT-01
7'-10" A.F.F. PLAN
ACT-01
SERVER
7'-8" A.F.F. ACT-01
ROOM
OFFICE 7'-10" A.F.F. OFFICE
B107B
C101A C105
ACT-01
GWB EX 7'-10" A.F.F. EXPOSED STRUCTURE TO REMAIN AS-
6'-10" A.F.F. IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
P P BE PREPPED AND DRYFALL PAINTED
TO MATCH EXISTING EXPOSED
ELECTRICAL ELECTRICAL
STAIR STRUCTURE WHERE APPLICABLE.
ROOM ROOM
- U.N.O. EXISTING LIGHTING TO BE
B107A B107 REUSED, BUT MAY NEED TO BE
171 SF 227 SF 33 SF ACT-01
RELOCATED DURING INSTALLATION OF
7'-10" A.F.F.
STORAGE NEW HVAC AND DRYFALL PAINTING.
B1 ACT-01 B105A
8'-0" A.F.F. 18 1'-4"
A-540
OPEN TO LEVEL 2
GWB EX 1'-4" GWB EX ACT-01 EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL
7'-9" A.F.F. 7'-9" A.F.F. 9'-1" A.F.F. PLANK CLOUD
01 CLASSROOM
GWB EX B1 01 B1 B106
7'-9" A.F.F. A-540 A-540
1'-4"

GWB EX
Q STUDY AREA 01 Q
7'-7" A.F.F.
144 ADVANCED
18 ACT-01
7'-8" A.F.F. CIRCUIT AREA N.I.C.
6'-0"

OFFICE LABORATORY
ACT-01 B108B ACT-01 B105
8'-0" A.F.F. ACT-01 7'-10" A.F.F. 1278 SF

GWB EX 7'-2" A.F.F.


7'-1 1/2" A.F.F. CEILING PLAN NOTES
OFFICE F
B108C ACT-01
7'-8" A.F.F. GWB EX
OPEN TO
LEVEL 2
3 G
ACT-01
7'-8" A.F.F. OFFICE
B108A
ACT-01
7'-2" A.F.F.
1'-0" 7'-1 1/2" A.F.F.
01
ACT-01
7'-6" A.F.F.
GRID CEILING 01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
E
2
01 18 18 B1
B1 ACT-01 MATCH EXISTING BUIDLING STANDARD. D
A-540 7'-6" A.F.F. A-540
R R 02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE
ACT-01 ORIGINAL CONSTRUCTION AND LIGHTING. C
7'-10" A.F.F. E.I.T.
BUSINESS B103C GWB EX OFFICE 03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS
AND FINANCE
CONFERENCE ACT-01 TEST
ENGINEERING ACT-01
7'-2" A.F.F. B103A
ACT-01 OFFICE
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED. B 1
ROOM 7'-2" A.F.F. SOLDERING 04
LAB 7'-7" A.F.F. 7'-8" A.F.F. LAB B101
B109 OFFICE
A
OPEN TO LEVEL 2 B104 B102 ACT-01
05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME
B100
GWB EX CIRCULATION 7'-9" A.F.F. INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
GWB EX OFFICE ACT-01
7'-1 1/2" A.F.F. - GWB EX 08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
7'-2" A.F.F. B103B 7'-9" A.F.F. ACT-01 KEY PLAN
7'-2" A.F.F.
ACT-01 7'-9" A.F.F. TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE
7'-8" A.F.F. ACT-01 REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
ACT-01 7'-8" A.F.F. 21 SEAL | DATE 04/01/21
S
7'-2" A.F.F.
S 09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
21 21
CUSTODIAL CIRCULATION ACT-01 GWB EX NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
STORAGE ELEV 2 B1 - 7'-9" A.F.F. 7'-1" A.F.F. 2.
B110 GWB EX
123 SF
-
GWB EX 7'-3" A.F.F.
A-540 11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
47 SF
GM ROOM 21 7'-3" A.F.F. . PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
B111 OPEN TO QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
STAIR
S10 S9 S8 S7 S6 S5 -
S4 S3 LEVEL 2 S2 S1 FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
ACT-01 SKYLIGHT
110 SF
7'-8" A.F.F. 6" NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
25 21
18 NEW RECESSED LIGHTING AS SHOWN.
18 01
GM ROOM GWB EX ACT-01 12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
1'-0" B111 7'-9" A.F.F. 7'-4" A.F.F. MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
SHEET ISSUE
T T LIGHTING AS SHOWN IN ELECTRICAL PLANS.
1 Construction Documents 04/01/21
E3
ANGLED PLANK AWP-02 GWB EX
14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS.
A-540 AWP-02
EXP AWP-02 8'-7" TO 10'-9" AFF 8'-7" A.F.F. 8'-0" A.F.F. 18 17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
9'-0" A.F.F. 10'-9" A.F.F. E5 OFFICE
GWB-X1 CIRCULATION A-540 A105 COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
10'-6" A.F.F. PT-01 21 OFFICE
9.8 OFFICE 8.9 7.9 - 6.9 5.9 5.5 5.1 4.1 A102A 3.1 2.1 134 SF
1.2 AS REQUIRED.
1'-0"

A140
ACT-01 SERVER ADMIN OFFICE OFFICE 18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
ACT-01 8'-11" A.F.F. ACT-01 ROOM A102 ACT-01 WORKROOM / A103 INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
8'-11" A.F.F. 8'-11" A.F.F. 7'-4" A.F.F.
OFFICE OFFICE
A100A BREAKROOM 181 SF AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
97 SF A102B OFFICE
OFFICE OFFICE A136 A138 ACT-01 REMOVED.
A106
7'-4" A.F.F.
A124 A126 139 SF 19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
ACT-01 GWB-X1
MITIGATE SOUND TRANSFER BETWEEN OFFICES.
U 31 U
8'-11" A.F.F. 7'-0" A.F.F. 21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
GWB-X1
31 CIRCULATION CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
WORKROOM / 7'-0" A.F.F.
-
CIRCULATION BREAKROOM OFFICE WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
ACT-01 A107
APPLICATIONS -
8'-11" A.F.F.
A122 ACT-01 STORAGE 138 SF
ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
READING 8'-6" A.F.F. A104B NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
ROOM ACT-01 33 WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
A130 8'-0" A.F.F. OFFICE
A101
CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
GWB-X1 OFFICE
OFFICE OFFICE SAFE
A128
6'-10" A.F.F.
A118 ELEC. AND A104A A104 OFFICE 23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
ACT-01 ACT-01 ELEC. STORAGE A108 ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
9'-0" A.F.F. 8'-11" A.F.F. 141 SF
ACT-01 A118A A101A
STORAGE
ACT-01 8'-11" A.F.F. 25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
A120A 8'-11" A.F.F. WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
V V
ADMIN OFFICE NEW TO MATCH EXISTING.
GWB EX CIRCULATION STORAGE CIRCULATION A113
A120 A120B - CIRCULATION
8'-0" A.F.F. ACT-01 -
33 26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
9'-3" A.F.F. 27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
OFFICE 29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
A109 CEILING AND EXTENSION TO APPEAR SEAMLESS. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
OFFICE OFFICE 205 SF
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
ACT-01 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
A121 OFFICE OFFICE OFFICE OFFICE OFFICE A116 OFFICE OFFICE OFFICE OFFICE OFFICE 30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK..
9'-3" A.F.F.
A123 A125 A127 A129 A117 A115 A114 A112 A111 A110
PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND PROJECT NO. 19010.000
ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT
SHEET TITLE
CAFE. AS SHOWN IN ELECTRICAL DRAWINGS..
31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER FIRST LEVEL
W W BULKHEADS IN ADJACENT AREA.
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG REFLECTED CEILING
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF
PLAN - AREA 1
4/1/2021 12:07:34 PM

RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND


COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
NEW 2X2 ACT CEILING.
33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG SHEET NUMBER
1 FIRST LEVEL - AREA 1 CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING
A-133.1
1/8" = 1'-0" S10 S9 S8 S7 S6 S5 S4 S3 S2 S1 FLOORING FINISHES ON LEVEL ABOVE.
A-133.1
GENERAL CEILING PLAN NOTES
N10 N9 N8 N7 N6 N5 N4 N3 N2 N1

GWB-X1
8'-11" A.F.F.
GWB-X1
GWB-X1
11'-3" A.F.F. TYP.
A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
RHIT MOENCH
GWB-X1
11'-3" A.F.F. TYP.
TYP.

TYP.
C7
A-622
11'-3" A.F.F.
TYP. GWB-X1 TYP.
8'-11" A.F.F.
GWB-X1
8'-11" A.F.F. TYP.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
RENOVATION

7"
6"

6"
7"
A A C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
FINISHES.
5500 Wabash Avenue
WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01 WT-01
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO
ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
Terre Haute, Indiana
REMAIN..
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
FACULTY
OFFICE
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
47803
F137 F135 F133 F131 F129 F127 F125 F123 F121 F119 F117 F115 F113 F111 F109 F107 DEPT. HEAD
6" EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED
F105A
TO BE SHOWN IN THE PLANS AND INSTALLED
Owner
7" 26 19 GWB-X1
ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 8'-11" A.F.F. TYP.
F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING Rose-Hulman Institute of Technology
9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. 9'-0" A.F.F. CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID 5500 Wabash Avenue
9'-0" A.F.F. GWB-X1 ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY
26 26 26 19 26 19 26 19 26 19 26 19 26 19 26 19 19 26 19 26 26 19 26 19 26 19 26 19 26 19 11'-3" A.F.F. TYP. CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH
Terre Haute, Indiana 47803
19 19 812-877-1511
GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN.
ACT-01
9'-0" A.F.F. G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS,
B B SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
18 18 26 19 WT-01 INDICATED.
H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
ADMIN OFFICE
I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
WT-01 18 F105 WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
GWB-X1 19 26 ACT-01 CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
8'-11" A.F.F. 9'-0" A.F.F. ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 INDICATED ON THE DRAWINGS.
ACT-01 ACT-01
9'-0" A.F.F. 7'-9" A.F.F. 7'-9" A.F.F. 7'-9" A.F.F. 7'-9" A.F.F. 7'-9" A.F.F. 7'-9" A.F.F. J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
9'-0" A.F.F. FACULTY
GWB-X1 EXP WT-01 ACT-01 REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
11'-3" A.F.F. OFFICE FACULTY FACULTY FACULTY FACULTY FACULTY FACULTY 8'-8" A.F.F. FACULTY FACULTY 9'-0" A.F.F. TYP. OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
OFFICE FACULTY ACT-01
FACULTY F130 OFFICE OFFICE OFFICE OFFICE COLLISION FACULTY OFFICE OFFICE GWB-X1 STARTING WORK. Architect
DATA OFFICE FACULTY 9'-0" A.F.F.
OFFICE F128 F126 F124 F122 F120 F116 OFFICE F108 F106 11'-3" A.F.F. TYP. K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
19 26 ALIGN F114 F112
F110 OFFICE RATIO
F132 PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER
26 26 19 26 19 26 26 26 ALIGN F103 26 19 LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS. 101 South Pennsylvania Street
18 19 19 19 19 26 19 26 19 26 19 26 19 Indianapolis, Indiana 46204
C PT-01 C
317-633-4040
CIRCULATION A2
GWB-X1
?
GWB-X1
7'-9" A.F.F. 18 FACULTY
ACT-01
9'-0" A.F.F.
CEILING LEGEND
ALIGN 7'-9" A.F.F. PT-01
- A-540 ? OFFICE
F101 JAN
128 SF
F100 Structural Engineer
ALIGN CEILING TAG
ACT-01 A2 19 26 EXP Fink Roberts & Petrie, Inc.
8'-8" A.F.F. A-540 8'-8" A.F.F. CEILING TYPE
18 XXX-01 9449 Priority Way W Dr #200
ACT-01 18 10'-10" A.F.F. Indianapolis, Indiana 46240
CEILING HEIGHT
8'-8" A.F.F. 317-872-8400
18 (ABOVE FINISH FLOOR)
STAIR
-
9.8 119 SF 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
GWB-X1 SPOT ELEVATION MARKER Mechanical / Electrical Engineer
7'-2" A.F.F.
R.E. Dimond & Associates, Inc.
D D 732 N Capitol Avenue
ACT-01 EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD Indianapolis, Indiana 46204
EQUIPMENT 8'-8" A.F.F. 18
REPAIR ROOM OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON 317-634-4672
27 E107A PLAN
SERVER/EQUIP. 18
N10 N9 N8 N7 STORAGE
N6 N5 N4 ACT-01 N3 N2 N1

5'-0"
E107C 18 8'-0" A.F.F.
ACT-01 ACT-01 CLASSROOM
27 7'-9" A.F.F. 7'-9" A.F.F. EXP E104
ACT-01 1958 SF
GWB-X1 9'-0" A.F.F. ELEV 1 7'-7" A.F.F. EXPOSED STRUCTURE TO REMAIN AS-
5'-0"
2 1/4" 7'-1" A.F.F. 18 BUILDING STANDARD 2'X2' GRID AND
- IS UNLESS NOTED OTHERWISE. NEW
84 SF DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
27 ACT-01
18 BE PREPPED AND DRYFALL PAINTED
EQ.

7'-10" A.F.F.
WOMENS R.R. TO MATCH EXISTING EXPOSED
E E109 E STRUCTURE WHERE APPLICABLE.
GWB-X1
TECHNICIAN EXP U.N.O. EXISTING LIGHTING TO BE
7'-1" A.F.F.
OFFICE 7'-9" A.F.F. REUSED, BUT MAY NEED TO BE
ACT-01 E107B RELOCATED DURING INSTALLATION OF
7'-10" A.F.F. MENS R.R. NEW HVAC AND DRYFALL PAINTING.
EXP
OPEN TO LEVEL 2 9'-0" A.F.F. E108
21 OPEN TO LEVEL 2
ACT-01
WORKSHOP 18 7'-8" A.F.F. EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL
E107 PLANK CLOUD

GWB-X2 CIRCULATION
7'-3" A.F.F. -
GWB EX
8'-0" A.F.F.
GWB-X1 AREA N.I.C.
F 7'-3" A.F.F. F
OFFICE
E102
ACT-01
EXP
21 7'-10" A.F.F.
9'-0" A.F.F.
CEILING PLAN NOTES F
GWB-X1
7'-3" A.F.F. 3 G
GWB EX
04 04 7'-9" A.F.F.
OFFICE
E101 01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
E
2
ACT-01 BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
7'-10" A.F.F. MATCH EXISTING BUIDLING STANDARD. D
G G 02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE
ORIGINAL CONSTRUCTION AND LIGHTING. C
OFFICE OFFICE OFFICE
D113 D108 D107 03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED.
B 1
ACT-01
7'-9" A.F.F. ACT-01 ACT-01 04
EXP REFERENCE 7'-3" A.F.F. 7'-9" A.F.F. A
9'-0" A.F.F. (CONFERENCE) 05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME
CLASSROOM ROOM
D112
INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
D110
ENERGY 21 OFFICE OFFICE PT-01 08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS KEY PLAN
OFFICE
CONVERSION D111-1 D111 TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE
ACT-01 ACT-01 D106
AND POWER EXP
132 SF 149 SF ACT-01 SEAL | DATE 04/01/21
SYSTEMS
7'-10" A.F.F. 7'-11" A.F.F.
7'-3" A.F.F. REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
7'-9" A.F.F.
LABORATORY 09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
H GWB-X1 ACT-01 H
D114 ACT-01
EXP ACT-01 ACT-01 7'-2" A.F.F. OFFICE 7'-10" A.F.F. NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
7'-1 1/2" A.F.F.
9'-0" A.F.F. 7'-10" A.F.F. 7'-9" A.F.F. D109 2.
11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
GWB-X1 GWB-X1 . PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
7'-1" A.F.F. 7'-1" A.F.F. OFFICE QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
21 D105 FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
OPEN TO LEVEL 2 21 GWB EX
EXP 7'-9" A.F.F. ACT-01 NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
9'-0" A.F.F. 7'-10" A.F.F.
ACT-01 NEW RECESSED LIGHTING AS SHOWN.
21 GWB EX 7'-10" A.F.F.
7'-9" A.F.F. 12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW SHEET ISSUE
J ACT-01 GWB EX GWB-X1 J LIGHTING AS SHOWN IN ELECTRICAL PLANS. 1 Construction Documents 04/01/21
7'-9" A.F.F. 7'-1" A.F.F. 7'-1" A.F.F.
OFFICE 14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS.
D104 17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
EXP
9'-0" A.F.F. ACT-01
COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
ACT-01 7'-10" A.F.F. AS REQUIRED.
GWB-X1 GWB-X1 7'-10" A.F.F. 18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
7'-1" A.F.F. 7'-1" A.F.F. INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
21 EXP
ACT-01 9'-0" A.F.F. AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
7'-2" A.F.F. OFFICE
ELECTRONIC D103 REMOVED.
CIRCUITS CALIBRATION EXP
LABORATORY ECE LAB TECH LEARNING 19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
LABORATORY 7'-9" A.F.F. CENTER DESIGN LAB
K D115 D116 D117
D101-A D101 K MITIGATE SOUND TRANSFER BETWEEN OFFICES.
ACT-01 ACT-01
7'-1 1/2" A.F.F. 7'-10" A.F.F. 21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
GWB-X1 CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
ACT-01 OFFICE 7'-1" A.F.F. WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
7'-11" A.F.F. D118 EXP
ACT-01
ACT-01 ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
9'-0" A.F.F. 7'-10" A.F.F.
OPEN TO LEVEL 2 STORAGE 7'-11" A.F.F. ACT-01
OFFICE
NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
D115A 7'-10" A.F.F.
PT-01 D102 WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
21 CIRCULATION
ACT-01
-
ACT-01
23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
7'-1" A.F.F. 7'-10" A.F.F. ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
GWB-X1 GWB-X1
7'-1" A.F.F. PT-01 PT-01 7'-1" A.F.F. 25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
L INSTRUMENT L
ROOM WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
EQUIPMENT NEW TO MATCH EXISTING.
C114 OFFICE
STORAGE
WORKSHOP/STORAGE C110
C115A
C112
26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
ACT-01 27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
7'-9" A.F.F. ACT-01
7'-9" A.F.F. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
21 EXP 29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
9'-0" A.F.F. CEILING AND EXTENSION TO APPEAR SEAMLESS. DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
ACT-01 ACT-01 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
7'-2" A.F.F. 7'-9" A.F.F. 30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK..
PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND PROJECT NO. 19010.000
OFFICE
OPEN TO LEVEL 2 MECHATRONICS C109
ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT SHEET TITLE
CAFE. AS SHOWN IN ELECTRICAL DRAWINGS..
C111
31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER
FIRST LEVEL
ACT-01
18
B1
A-540
7'-9" A.F.F.
32
BULKHEADS IN ADJACENT AREA.
REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG
REFLECTED CEILING
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF PLAN - AREA 2
4/1/2021 12:07:36 PM

9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND
COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
NEW 2X2 ACT CEILING.
1 FIRST LEVEL - AREA 2 33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG
SHEET NUMBER
A-133.2
1/8" = 1'-0"
CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING
FLOORING FINISHES ON LEVEL ABOVE. A-133.2
GENERAL CEILING PLAN NOTES
A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
RHIT MOENCH
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
RENOVATION
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
FINISHES.
5500 Wabash Avenue
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO
ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
REMAIN..
Terre Haute, Indiana
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL 47803
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED
TO BE SHOWN IN THE PLANS AND INSTALLED Owner
F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING
CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID Rose-Hulman Institute of Technology
ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY 5500 Wabash Avenue
CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH Terre Haute, Indiana 47803
GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN. 812-877-1511
G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS,
SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
INDICATED.
H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
INDICATED ON THE DRAWINGS.
J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
STARTING WORK. Architect
CLASSROOM CLASSROOM K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
G308 G306
STUDENT PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER RATIO
WORK AREA LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS. 101 South Pennsylvania Street
G304 Indianapolis, Indiana 46204
CLASSROOM
317-633-4040
G310
940 SF
17 ACT-01
9'-0" A.F.F.
17 CEILING LEGEND
18 CEILING TAG
18 Structural Engineer
CEILING TYPE
18 XXX-01 Fink Roberts & Petrie, Inc.
ACT-01 A7 ACT-01
9'-0" A.F.F. 9'-0" A.F.F. 10'-10" A.F.F.
A-351 CEILING HEIGHT 9449 Priority Way W Dr #200
(ABOVE FINISH FLOOR) Indianapolis, Indiana 46240
CLOSET 317-872-8400
G304A
8 SF SPOT ELEVATION MARKER
Mechanical / Electrical Engineer
CIRCULATION R.E. Dimond & Associates, Inc.
STAIR - EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD 732 N Capitol Avenue
1390 SF OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON
- Indianapolis, Indiana 46204
178 SF PLAN
317-634-4672

EXPOSED STRUCTURE TO REMAIN AS-


IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
13 SEAT DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
CONF. BE PREPPED AND DRYFALL PAINTED
G305 STAIR TO MATCH EXISTING EXPOSED
- STRUCTURE WHERE APPLICABLE.
123 SF U.N.O. EXISTING LIGHTING TO BE
REUSED, BUT MAY NEED TO BE
RELOCATED DURING INSTALLATION OF
18
CLASSROOM CLASSROOM CLASSROOM NEW HVAC AND DRYFALL PAINTING.
G317 G315 G313
860 SF 854 SF 824 SF
ACT-01
9'-0" A.F.F. STORAGE
G305A
EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL
PLANK CLOUD

ACT-01
9'-0" A.F.F.

AREA N.I.C.

CEILING PLAN NOTES

F
01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG 3 G
BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
1
A-133.3
FIRST LEVEL - AREA 3 MATCH EXISTING BUIDLING STANDARD.
E
2
1/8" = 1'-0"
02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE D
ORIGINAL CONSTRUCTION AND LIGHTING.
03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS C
FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED.
04 B 1
05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME
INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS. A
08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE KEY PLAN
REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH SEAL | DATE 04/01/21
NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
2.
11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
. PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
NEW RECESSED LIGHTING AS SHOWN.
12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
LIGHTING AS SHOWN IN ELECTRICAL PLANS.
SHEET ISSUE
14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS.
1 Construction Documents 04/01/21
17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
AS REQUIRED.
18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
REMOVED.
19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
MITIGATE SOUND TRANSFER BETWEEN OFFICES.
21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
NEW TO MATCH EXISTING.
26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT
CEILING AND EXTENSION TO APPEAR SEAMLESS. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT PROJECT NO. 19010.000
CAFE. AS SHOWN IN ELECTRICAL DRAWINGS..
SHEET TITLE
31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER
BULKHEADS IN ADJACENT AREA. FIRST LEVEL
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF REFLECTED CEILING
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND
COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH PLAN - AREA 3
4/1/2021 12:07:39 PM

NEW 2X2 ACT CEILING.


33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG
CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING SHEET NUMBER
FLOORING FINISHES ON LEVEL ABOVE.

A-133.3
GENERAL CEILING PLAN NOTES
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2

A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.


B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
RHIT MOENCH
RENOVATION
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
STORAGE
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
L
D226D
L FINISHES.
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO
5500 Wabash Avenue
ALIGN ALIGN OFFICE
C212
OFFICE
C211
ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
REMAIN..
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
Terre Haute, Indiana
MECHANICAL
ROOM
EXPOSED
WOOD DECK
ACT-01
7'-10" A.F.F.
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED
47803
ABOVE MECHANICAL TO BE SHOWN IN THE PLANS AND INSTALLED
C215 ROOM
557 SF F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING Owner
C214 CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID
OFFICE ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY
Rose-Hulman Institute of Technology
EXP ACT-01 C210 CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH 5500 Wabash Avenue
9'-7" A.F.F. 7'-10" A.F.F. ACT-01 GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN. Terre Haute, Indiana 47803
ALIGN ALIGN 7'-10" A.F.F. G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, 812-877-1511
SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE
M M INDICATED.
B1 ACT-01 IT CLOSET OFFICE H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
GWB EX A-540 8'-6" A.F.F. C200B ACT-01 I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
8'-6" A.F.F. C209
18 GWB EX C.J. 7'-11" A.F.F. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
C.J. 7'-9" A.F.F. C.J. CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT

1'-0"
C.J. GWB EX 01 ACT-01
01 7'-10" A.F.F. INDICATED ON THE DRAWINGS.
7'-9" A.F.F. 1'-0" J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS

1'-0"
STUDY AREA 1'-0" STAFF
A2 - D6 RESOURCES ACT-01 REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
CIRCULATION B1
A-301 A-322 C200 ACT-01 8'-6" A.F.F. OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
SKYLIGHT - SKYLIGHT A-540
STARTING WORK.
8'-6" A.F.F. OFFICE
C.J. 5103 SF

1'-0"
ACT-01

1'-0"
01 01 01 01 ACT-01 C208 K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH Architect
8'-6" A.F.F. 18 1'-6" 8'-6" A.F.F. PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER
GWB EX C.J. ACT-01 RATIO
C.J. B1 LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS.
B1 A-540 7'-10" A.F.F. 1'-6" D3 18 C.J. STORAGE 7'-10" A.F.F. 101 South Pennsylvania Street
A-540 A-322 C200A Indianapolis, Indiana 46204
N N CEILING LEGEND 317-633-4040
CIRCULATION
GWB EX CIRCULATION
ACT-01 7'-9" A.F.F. -
7'-10" A.F.F. Structural Engineer
CEILING TAG
Fink Roberts & Petrie, Inc.
CEILING TYPE
OFFICE 25 25 XXX-01 9449 Priority Way W Dr #200
ACT-01
C216 8'-0" A.F.F. 10'-10" A.F.F. CEILING HEIGHT
Indianapolis, Indiana 46240
EXPOSED 21 317-872-8400
OFFICE (ABOVE FINISH FLOOR)
WOOD DECK
ACT-01 C217 ABOVE
7'-10" A.F.F.
ACT-01 ALIGN ALIGN SPOT ELEVATION MARKER Mechanical / Electrical Engineer
7'-10" A.F.F.
R.E. Dimond & Associates, Inc.
O MECHANICAL O
ROOM
732 N Capitol Avenue
GWB-X1 ADMIN EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD Indianapolis, Indiana 46204
C201
8'-7 1/2" A.F.F. C205 OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON 317-634-4672
OFFICE
C206 PLAN
MECHANICAL MECHANICAL
ROOM ROOM
C218 C201 ACT-01 ACT-01
8'-0" A.F.F. 7'-10" A.F.F.
EXPOSED STRUCTURE TO REMAIN AS-
IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
ALIGN ALIGN STORAGE BE PREPPED AND DRYFALL PAINTED
C205B TO MATCH EXISTING EXPOSED
P P STRUCTURE WHERE APPLICABLE.
U.N.O. EXISTING LIGHTING TO BE
REUSED, BUT MAY NEED TO BE
RELOCATED DURING INSTALLATION OF
21 GWB EX 21 NEW HVAC AND DRYFALL PAINTING.
8'-7" A.F.F.
GWB EX MECHANICAL
7'-1" A.F.F. ROOM
B202 EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL
25 W9NAA ROSE 335 SF
PLANK CLOUD
MECHANICAL TECH RADIO
GWB EX
21 ROOM CLUB
8'-7" A.F.F.
B203 B204
PT-01 ALIGN ALIGN
ACT-01
7'-7" A.F.F. AREA N.I.C.
Q 32 Q
PROJECTION ADVANCED
ROOM EXISTING CIRCUIT
B111A VERTICAL ACT-01 LABORATORY
ACT-01 CONSTRU 7'-11" A.F.F. B105
8'-0" A.F.F. CTION OF OFFICE 1278 SF CEILING PLAN NOTES
BULKHEAD STUDENT BBE HIVE B201
TO CONFERENCE 229 SF
EXISTING TO REMAIN ROOM B205 F
REMAIN -
REBUILD B205A 01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
3 G

32 NEW ACT
HORIZONT
AL AS
REQUIRED
ACT-01 ACT-01
ACT-01
7'-9" A.F.F.
STAIR
MATCH EXISTING BUIDLING STANDARD.
E
2
.
7'-10" A.F.F. 7'-8" A.F.F. CIRCULATION
ALIGN ALIGN 300-1 02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE D
PT-01 -
EXISTING TO REMAIN 111 SF ORIGINAL CONSTRUCTION AND LIGHTING.
R 32 32 R 03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS C
EXISTING FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED.
VERTICAL
CONSTRU
CTION OF
ACT-01
8'-0" A.F.F. DIGITAL
04
05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME
B 1
SYNTHETIC SIGNAL
BULKHEAD INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
32 NEW ACT TO
BIOLOGY PROCESSING A
LABORATORY LAB
REMAIN - B206 B200 08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
REBUILD ACT-01 TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE
HORIZONT 7'-11" A.F.F. KEY PLAN
AL AS
REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.
REQUIRED 09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
. PT-01 ALIGN ALIGN SEAL | DATE 04/01/21
32 NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
S 32 EXISTING TO REMAIN 32 S 2.
21 GWB EX GWB EX 11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
32 NEW ACT 8'-8" A.F.F. 8'-8" A.F.F.
ELEV 2 GWB EX CLERESTORY GLAZING ABOVE . PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
- 7'-9" A.F.F. QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
42 SF
GM ROOM 21 E5 FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
EXISTING A-321
32 B111 MECHANICAL NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
VERTICAL ROOM
S10 S9 CONSTRUCTION S8 S7 S6 S5 21 S4 S3 S2 S1 NEW RECESSED LIGHTING AS SHOWN.
B207
PT-01 OF BULKHEAD TO 469 SF 12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
REMAIN - REBUILD
HORIZONTAL AS
21
GWB EX
CIRCULATION 21 MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
REQUIRED. 21 - GWB EX LIGHTING AS SHOWN IN ELECTRICAL PLANS.
GWB EX 11'-2" A.F.F. 8'-8" A.F.F.
8'-8" A.F.F. E1 SHEET ISSUE
14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS.
T A-321 T 1 Construction Documents 04/01/21
17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
4'-11" 6'-4" 4'-11" GWB EX COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
10" 2" 24'-0" 2" 10" 7'-2" A.F.F.
CIRCULATION AS REQUIRED.
10"

ACT-01
- 7'-4" A.F.F. 18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 ACT-01
1.2 INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
2"

ADMIN OFFICE OFFICE MENS R.R. 11'-4" A.F.F. AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
ACT-01
A218 A218A AWP-01 7'-4" A.F.F. CIRCULATION
11'-0" A.F.F. E1 A223
-
REMOVED.
A-540
ACT-01 CUSTODIAL CLASSROOM 19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
11'-3" A.F.F. ACT-01 WOMENS R.R.
11'-3" A.F.F. A222 STORAGE A202 MITIGATE SOUND TRANSFER BETWEEN OFFICES.
20'-0"

A223A
ACT-01
21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
11'-4" A.F.F. CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
U 29 25 U
WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
09
29 A2 ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
PT-01b
ABOVE 4'-10" A-351
ELECTRICAL NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
OFFICE OFFICE BREAKROOM ROOM OFFICE WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
GWB-X1 STORAGE /
A218C A218B A200
10" 2"

18 11'-3" A.F.F. A200A A201 PROJECTOR CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
ACT-01 ACT-01 PT-01 ACT-01 ACT-01 A202A OFFICE
GWB EX 11'-3" A.F.F. 11'-3" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. A203A
23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
10'-0" A.F.F. ACT-01 WORK AREA / ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
29 STORAGE
11'-4" A.F.F.
A203 ACT-01 25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
CIRCULATION 11'-4" A.F.F. WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
25 25 - 25 ACT-01 NEW TO MATCH EXISTING.
V 11'-3" A.F.F. V 26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
CIRCULATION
GWB EX GWB EX OFFICE 27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
2'-1"

GWB EX GWB EX GWB EX -


8'-6" A.F.F. 8'-6" A.F.F. 8'-6" A.F.F. 8'-6" A.F.F. 8'-6" A.F.F. A203B
29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT
GWB EX
2'-0" 2'-0"
GWB EX GWB EX
ACT-01
CEILING AND EXTENSION TO APPEAR SEAMLESS.
8'-6" A.F.F. 2'-0" 2'-0" 2'-0" 2'-0" 8'-6" A.F.F. 2'-0" EQ. EQ. 8'-6" A.F.F. 2'-0" 2'-0" 2'-0" 2'-0" COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
11'-4" A.F.F. 30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
OFFICE OFFICE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A209 ADMIN OFFICE OFFICE A203D PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE A208 WORKROOM OFFICE OFFICE A204
A217 A216 A215 A214 A213 A212 A211 A210 2'-0" A207 A206 A205
ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT
OFFICE PROJECT NO. 19010.000
A203C CAFE. AS SHOWN IN ELECTRICAL DRAWINGS..
ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01
ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 ACT-01 14'-0" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. ACT-01 31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER SHEET TITLE
11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F.

32
BULKHEADS IN ADJACENT AREA.
REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG
SECOND LEVEL
W W EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND
REFLECTED CEILING
COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH PLAN - AREA 1
4/1/2021 12:07:45 PM

NEW 2X2 ACT CEILING.


33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG
CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING
SHEET NUMBER
FLOORING FINISHES ON LEVEL ABOVE.
1 SECOND LEVEL - AREA 1
A-134.1
1/8" = 1'-0" S10 S9 S8 S7 S6 S5 S4 S3 S2 S1
A-134.1
N10 N9 N8 N7 N6 N5 N3 N2 N1
GENERAL CEILING PLAN NOTES
A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS.
B. INSTALL NEW ACT CEILINGS AT 1" LOWER THAN EXISTING HEIGHT UNLESS NOTED OTHERWISE.

A A
G.C. TO COORDINATE PROVISION OF INFORMATION REGARDING EXISTING CEILING HEIGHTS.
CONFIRM ALL CEILING HEIGHTS INDICATED ON PLAN AND IMMEDIATELY REQUEST
CONFIRMATION FROM ARCHITECT IF THERE IS A CONFLICT BETWEEN HEIGHT SHOWN ON PLAN
RHIT MOENCH
AND ACHIEVING HEIGHT 1" LOWER THAN CURRENTLY IN FIELD.
C. UNLESS NOTED OR SHOWN OTHERWISE, EXISTING BULKHEADS ARE TO REMAIN, UNLESS
REMOVAL IS REQUIRED FOR HVAC INSTALLATION. IF REPAINTING IS REQUIRED, MATCH EXISTING
RENOVATION
CONFERENCE FINISHES.
ROOM
F230
OFFICE
F228
OFFICE
F226
OFFICE
F224
OFFICE
F222
OFFICE
F220
OFFICE
F218
OFFICE
F216
OFFICE
F214
OFFICE
F212
OFFICE
F210
D. UNLESS NOTED OTHERWISE, ALL ROOMS SHOWN AS OPEN DECK TO REMAIN ARE TO ALSO
ASSUME THAT EXISTING LIGHTING IS TO REMAIN AND EXISTING CEILING FINISHES ARE TO
5500 Wabash Avenue
REMAIN..
E. UNLESS NOTED OR SHOWN OTHERWISE, ALL ROOMS SHOWN WITH NEW GRID TO RECIEVE NEW
2'X2' ACOUSTICAL CEILING GRID (BASIS OF DESIGN IS ARMSTRONG 1732 WITH TEGULAR REVEAL
Terre Haute, Indiana
EDGE AND CORRESPONDING CHICAGO METALLIC 15/16" EXPOSED TEE GRID). GRID IS INTENDED
TO BE SHOWN IN THE PLANS AND INSTALLED
47803
F. AT EXISTING LOCATION SUCH THAT EXISTING LIGHTING TO BE RAISED ABOVE GRID DURING
CIRCULATION CEILING WORK AND THEN CLEANED, SERVICED AS REQUIRED AND RELOCATED INTO NEW GRID Owner
- STORAGE ONCE CEILING WORK IS COMPLETED. THIS MEANS THAT THE CEILING GRID IS NOT NECESSARILY
F208 CENTERED IN THE ROOM TO ALLOW FOR REUSE OF LIGHTING CONDUIT. IN NEW AREAS WITH
Rose-Hulman Institute of Technology
B ADMIN OFFICE B 5500 Wabash Avenue
GRID THAT DID NOT PREVIOUSLY HAVE GRID CEILING, CENTER WITHIN SPACE AS SHOWN.
F231 G. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, Terre Haute, Indiana 47803
BREAK AREA SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE 812-877-1511
F207 INDICATED.
USABILITY H. PAINT NEW GYPSUM BOARD CEILING SURFACES AS SHOWN ON RCP'S.
LAB I. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED.
OFFICE
F225A WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL
F206 CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
WORKROOM /
BREAKROOM INDICATED ON THE DRAWINGS.
F233 J. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS
REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER
OFFICE
OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO
F205 STARTING WORK.
USABILITY
LAB CONTROL CSSE LAB CSSE LAB K. NEW EXPOSED DUCTS/ HVAC UNITS AT EXPOSED STAINED WOOD DECK CEILINGS TO BE BRUSH
C ROOM F225 F217 C PAINTED IN APPROPRIATE COATING TO MATCH PT-01, VERIFY COLOR OF PAINT AT ALL OTHER Architect
F225B LOCATIONS OF EXPOSED DUCTWORK AND HVAC UNITS.
OFFICE RATIO
F204 101 South Pennsylvania Street
CEILING LEGEND Indianapolis, Indiana 46204
317-633-4040
STAIRWELL
- CEILING TAG
OFFICE
CUSTODIAL Structural Engineer
F203
- CEILING TYPE Fink Roberts & Petrie, Inc.
XXX-01
10'-10" A.F.F. CEILING HEIGHT 9449 Priority Way W Dr #200
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2
(ABOVE FINISH FLOOR) Indianapolis, Indiana 46240
317-872-8400
D ACT-01 D
8'-0" A.F.F. SPOT ELEVATION MARKER
2'-0"

CIRCULATION 18 Mechanical / Electrical Engineer


-

PT-01

PT-01
R.E. Dimond & Associates, Inc.
N10 N9 N8 N7 N6 GWB-X1 N5 N3 02 N2 N1 EXISTING PAINTED GYB BOARD CEILING NEW OR PATCHED PAINTED GYB BOARD 732 N Capitol Avenue
MECHANICAL 7'-6" A.F.F. 18
ROOM
OR BULKHEAD AS SHOWN ON PLAN CEILING OR BULKHEAD AS SHOWN ON Indianapolis, Indiana 46204
CLASSROOM PLAN 317-634-4672
G116 WOMENS R.R.
GWB-X1 E104
30 E202 1958 SF
7'-6" A.F.F. ELEV 1
-
84 SF
ALIGN ALIGN
1'-6" 2'-0"

EXPOSED STRUCTURE TO REMAIN AS-


IS UNLESS NOTED OTHERWISE. NEW BUILDING STANDARD 2'X2' GRID AND
E 3'-0" E DUCTWORK AND HVAC EQUIPMENT TO CEILING TILES
12 PT-01b BE PREPPED AND DRYFALL PAINTED
EXPOSED
TO MATCH EXISTING EXPOSED
F7 WOOD
STRUCTURE WHERE APPLICABLE.
PT-01b A-540 DECK
U.N.O. EXISTING LIGHTING TO BE
ABOVE

PT-01

PT-01
AWP-01 GWB-X1 REUSED, BUT MAY NEED TO BE
9'-3" A.F.F. 9'-5" A.F.F. MECHANICAL
RELOCATED DURING INSTALLATION OF
ROOM 02 02
NEW HVAC AND DRYFALL PAINTING.
E201
30 PT-01 EXP
E1
12 12'-0" A.F.F.
A-540

2'-8" PT-01b EXISTING EXPOSED WOOD BEAM ARMSTRONG WOODWORKS ACOUSTICAL


PT-01
3'-0"

ALIGN ALIGN PLANK CLOUD


10"
1'-6"

12
F ACT-01 F
ACT-01 C.J 8'-9" A.F.F.
8'-1" A.F.F. CIRCULATION
.
- C.J
1838 SF 21 1'-0" AREA N.I.C.
PT-01 .
18

PT-01

PT-01
E7 01 SKYLIGHT

10'-0 1/8"
01 GWB EX A-540 SEATING 21
30 8'-0" A.F.F. 01 A6
E200 A-322
A5 GWB EX
A-301 SKYLIGHT 21 8'-0" A.F.F.
GWB EX GWB EX C.J CEILING PLAN NOTES
PT-01 8'-0" A.F.F. 8'-0" A.F.F. C.J .01
E6 . F
04
18
A-351 21
A3
02
01 IF POSSIBLE, REUSE EXISTNG VERTICAL AND PORTION OF HORIZONTAL FACE OF EXISITNG
3 G
G A-322 G BULkHEAD TO CREATE PERIMETER OF NEW ACT CEILING AS SHOWN. REPAINT AS REQUIRED TO
MATCH EXISTING BUIDLING STANDARD.
E
2
CIRCULATION 21 21
- GWB EX GWB EX ACT-01 OFFICE
02 RECONSTRUCT PERIMETER BULKHEADS WHERE HVAC WORK REQUIRED REMOVAL TO REPLICATE D
OFFICE ACT-01 7'-9" A.F.F. 7'-9" A.F.F. 7'-11" A.F.F. D208
D222 ACT-01 7'-10" A.F.F. ORIGINAL CONSTRUCTION AND LIGHTING.
7'-10" A.F.F. ACT-01
03 PROVIDE NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER LINEAR LIGHTING ON THIS C
ACT-01 7'-10" A.F.F.
PT-01

PT-01

7'-10" A.F.F. FLOOR. PATCH AND PAINT EXPOED CEILING ELEMENTS AS REQUIRED.
OFFICE OFFICE
OFFICE
D220
OFFICE OFFICE OFFICE
D207
04
B 1
D223 D224 D221 D209
05 NO HEADER AT THIS LOCATION . PROVIDE BLOCKING ABOVE CEIILNG TO SUPPORT DOOR FRAME A
ACT-01 INSERTED WITHINT FINISHED OPENING. DRYWALL CEILING IS CONTINUOUS.
7'-10" A.F.F. STORAGE ALIGN ALIGN ACT-01 ACT-01 ACT-01 ACT-01
D223A
7'-10" A.F.F. 7'-11" A.F.F. 7'-10" A.F.F. 7'-10" A.F.F. 08 PROVIDE ALTERNATE BID TO REPLACE EXISTING LIGHTING WITH NEW SURFACE MOUNTED LINEARS
H H TO MATCH OTHER LINEAR LIGHITNG ON THIS FLOOR. INCLUDE POSSIBLE TOUCH UP THAT MAY BE KEY PLAN
9"

OFFICE CIRCULATION STUDENT REQUIRED TO CEILING AFTER CHANGE IN LIGHTING.


OFFICE
D225 - STUDY AREA SEAL | DATE 04/01/21
EXPOSED OFFICE
CONFERENCE
D210
D206 09 ACOUSTICAL LINEAR WOOD PLANK CEILING EQUAL TO ARMSTRONG WOODWORKS GRILLE WITH
ACT-01 D219A NRC OF .90. WHERE SHOWN, ASSUME RECESSED LINEAR LIGHTING EQUAL TO FOCAL POINT SEEM
WOOD D219U
7'-10" A.F.F. ACT-01
ACT-01 DECK ACT-01 7'-11" A.F.F. 2.
A3 ABOVE 7'-10" A.F.F.
PT-01

PT-01

7'-10" A.F.F.
A-321 ACT-01 ACT-01
11 DESIGN INTENT IS TO EXPOSED STRUCTURE CEILING - PAINT DRYFALL PAINT IF NOT WOOD TIMBER.
OFFICE OFFICE 7'-10" A.F.F. 7'-10" A.F.F. OFFICE . PROVIDE SURFACE MOUNTED LED LINEAR FIXTURES TO MATCH NEW BUILDING STANDARD IN
D226 D227 OFFICE D205 QUANTITIES AND PLACEMENT TO ACHIEVE APPROPRIATE FOOTCANDLE LEVELS RECOMMENDED
ACT-01 D219V ACT-01 ACT-01 FOR INDICATED ROOM FUNCTION PER IES STANDARDS IF EXPOSING THE EXISTING STRUCTURE IS
7'-10" A.F.F. ACT-01 7'-10" A.F.F. 7'-11" A.F.F. NOT POSSIBLE DUE TO UNFORESEEN CIRCUMSTANCES, PROVIDE STANDARD 2'X2' ACT TILE WITH
STORAGE 7'-10" A.F.F. ALIGN ALIGN
D226A NEW RECESSED LIGHTING AS SHOWN.
J 10 SF J
STORAGE / OFFICE
12 EXPOSED STRUCTURE CEILING. RECONFIGURE DUCTS, PIPES AND CONDUIT AS REQUIRED TO
OFFICE
WORKROOM
21
CIRCULATION D218 D204 MINIMIZE IN EXPOSED AREAS WHERE POSSIBLE, DRYFALL PAINT AND PROVIDE PROVIDE NEW
ACT-01 D226C D217 ACT-01 ACT-01
7'-10" A.F.F. 7'-10" A.F.F. 7'-10" A.F.F. LIGHTING AS SHOWN IN ELECTRICAL PLANS. SHEET ISSUE
ACT-01
14 REPAINT DRYWALL AND REPLACE EXISTING DOWNLIGHTS WITH NEW LED DOWNLIGHTS. 1 Construction Documents 04/01/21
PT-01

PT-01

7'-10" A.F.F. ACT-01


OFFICE 7'-10" A.F.F. 17 PROVIDE MOTORIZED PROJECTION SCREEN AT FRONT OF ROOM AND PROJECTOR MOUNT TO
OFFICE D216
D228 COORDINATE WITH PROJECTOR AND SPACED AS REQUIRED. COORDINATE STRUCTURAL SUPPORT
GWB-X1
ADMIN OFFICE
8'-7 1/2" A.F.F. OFFICE
OFFICE OFFICE AS REQUIRED.
D229 ACT-01 D211 D203
ACT-01 7'-10" A.F.F.
D217 18 PROVIDE NEW CEILING WITH NEW LIGHTING AS SHOWN. IF NO NEW LIGHTING IS SHOWN, DESIGN
ACT-01 ACT-01
7'-11" A.F.F. 7'-10" A.F.F. GWB-X1 7'-10" A.F.F. ACT-01 ACT-01 INTENT IS TO REUSE EXISTING WALL SCONCES. COORDINATE WITH ELECTRICAL LIGHTING PLANS
ALIGN ALIGN 7'-10" A.F.F. 7'-10" A.F.F.
7'-1" A.F.F. STORAGE AS REQUIRED. PATCH TOP OF PERIMETER WALLS AS REQUIRED WHERE EXISTING CEILNGS WERE
D217A REMOVED.
K K
A6 ACT-01
A-350 ACT-01 CIRCULATION ACT-01 FACULTY OFFICE 19 PROVIDE SOUND BOOTS AT HVAC ABOVE CEILING AND INSULATE AS REQUIRED ABOVE CEILING TO
7'-10" A.F.F. 7'-10" A.F.F.
ACT-01 - CIRC. 7'-10" A.F.F. OFFICE D202 MITIGATE SOUND TRANSFER BETWEEN OFFICES.
OFFICE CONFERENCE
7'-10" A.F.F. D215 D215B
PT-01

PT-01

D230
145 SF ROOM ACT-01 21 IF POSSIBLE, EXISTING DRYWALL BULIKHEAD AND/OR CEILING AND LIGHTING ARE TO REMAIN;. iF
7'-10" A.F.F.
OFFICE
D212 CEILING MUST BE PARTIALLY DEMOLISHED TO ACCOMODATE NEW HVAC CONFIGURATION, PATCH
OFFICE
ACT-01 D214 ACT-01 WITH NEW AS NEEDED AND REPAINT BULKHEAD. IF ADJACENT DRYWALL CEILING AT HIGHER
7'-10" A.F.F. D215A ACT-01 7'-11" A.F.F.
ACT-01 7'-10" A.F.F. ELEVATION IS BEING REMOVED TO BE REPLACED BY ACT GRID CIELING, DEISGN INTENT IS FOR
7'-10" A.F.F. OFFICE OFFICE NEW ACT CEILING TO BE 1" LOWER THAN REMOVED DRYWALL SUCH THAT MINIMAL TOUCH UP
D232 ACT-01 D201
OFFICE
7'-10" A.F.F.
WORK IS REQUIRED AT PERIMETER OF BULKHEAD TO REMIAN. REUSE LIGHTING IF POSSIBLE.
D231 ACT-01 ACT-01 ACT-01
7'-10" A.F.F. CONFIRM DESIGN INTENT WITH ARCHITECT PRIOR TO REPLACEMENT.
STORAGE 7'-10" A.F.F. 7'-10" A.F.F.
D226D 23 NEW SURFACE MOUNTED LINEAR LIGHTING TO MATCH OTHER FIXTURES ON THIS FLOOR. THESE
L L ARE REPLACING FIXTURES WITH RED HOUSING THAT WERE REMOVED.
OFFICE 25 DESIGN INTENT IS FOR NEWLY CONSTRUCTED CEIING AND LIGHTING TO REMAIN. IF MECHANICAL
ALIGN ALIGN OFFICE
C211
C212 WORK PROHIBITS THIS, SALVAGE REMOVED COMPONENTRY AND REINSTALL OR REPLACE WITH
EXPOSED ACT-01 NEW TO MATCH EXISTING.
MECHANICAL
PT-01

PT-01

WOOD DECK 7'-10" A.F.F.


ROOM MECHANICAL 26 REFERENCE ELECTRICAL DRAWINGS FOR NEW LIGHTING IN NEWLY CONSTRUCTED ROOMS.
C215 ABOVE
ROOM
557 SF
C214
27 ADDED FIXTURE FOR INCREASED LIGHT LEVEL
OFFICE 29 ALIGN EXTENDED NEW GRID WITH EXISTING. GRID AND TILE MUST MATCH EXISTING ADJACENT
EXP ACT-01 C210 CEILING AND EXTENSION TO APPEAR SEAMLESS. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
9'-7" A.F.F. 7'-10" A.F.F. ACT-01 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
ALIGN ALIGN 7'-10" A.F.F. 30 EXISTING HARDLID CEILING AND SUSPENDED CLOUDS REQUIRE REMOVAL FOR HVAC WORK.. DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
PROVIDE NEW 2'X2' ACT GRID AND CEILING AS SHOWN. REUSE EXISTING LINEAR PENDANTS AND
M B1 ACT-01
M ADD ADDITIONAL LIGHTING FOR NEW LIVE VEGETATION WALL AND DECORATIVE PENDANTS AT PROJECT NO. 19010.000
IT CLOSET OFFICE
A-540 8'-6" A.F.F. C200B ACT-01
CAFE. AS SHOWN IN ELECTRICAL DRAWINGS.. SHEET TITLE
C209
7'-11" A.F.F. 31 PROVIDE NEW DRYWALL BULKHEAD AS SHOWN TO MATCH CONSTRUCTION ASSEMBLY OF OTHER
01 BULKHEADS IN ADJACENT AREA. SECOND LEVEL
D6
A-322
32 REMOVE HORIZONTAL PORTIONS OF HARDLID CEILINGS ON SOUTH ABOVE STAGE AND ALONG
EAST WALL. VERTICAL PORTION OF THESE BULKHEADS CAN REMAIN FOR EASE OF
REFLECTED CEILING
RECONSTRUCITON AFTER HVAC WORK IS COMPLETED. DRYWALL WRAPPED TRUSSES AND PLAN - AREA 2
4/1/2021 12:07:51 PM

9.8 8.9 7.9 6.9 5.9 5.5


C2 5.1 4.1 3.1 2.1 1.2 COFFERED CIELING AT NORTH END ARE TO REMAIN. REPLACE EXISTING WOOD SLAT CEILING WITH
A-301 NEW 2X2 ACT CEILING.
33 REPAIR PORTION OF DEMOLISHED CEILING AND FLOOR ABOVE IF APPLICABLE TO MATCH EXISITNG
CONSTRUCTION ASSEMBLY AND MATERIALS SUCH THAT REPAIR IS VISIBLY SEAMLESS, INCLUDING SHEET NUMBER
1 SECOND LEVEL - AREA 2 FLOORING FINISHES ON LEVEL ABOVE.
A-134.2
1/8" = 1'-0"
A-134.2
GENERAL FINISH PLAN NOTES
08-G1 08-G1 08-G1 08-G1 08-G1 08-G1
08-G1 08-G1
08-G1 08-G1
09-N1 09-N1 09-N1 09-N1 09-N1 09-N1
09-N1 09-N1
09-N1 09-N1 A. THESE GENERAL NOTES APPLY TO SERIES A150 PLANS.
08-G1
09-N1
DEPT. HEAD
FACULTY OFFICE
FL115
FACULTY OFFICE
FACULTY OFFICE FL111 FACULTY OFFICE
FACULTY OFFICE
FL107
FACULTY OFFICE
FACULTY OFFICE FL103
B. PAINT NEW AND EXISTING HOLLOW METAL DOORS, DOOR
FRAMES, AND LINTELS EXPOSED TO VIEW IN FINISHED
AREAS AND AT EXTERIOR LOCATIONS UNLESS OTHERWISE
RHIT MOENCH
FACULTY OFFICE INDICATED.
FL116B
W PT-02
B RB-01
W PT-02
B RB-01
F CPT-01
FL113
W PT-02
B RB-01
W PT-02
B
F
RB-01
CPT-01
FL109
W PT-02
B RB-01
W PT-02
B RB-01
F CPT-01
FL105
W PT-02
B RB-01
W
F
PT-02
B RB-01
CPT-01 W
FL101
PT-02
B RB-01
C. PAINT STEEL COLUMNS, BEAMS, STRUCTURE, ETC.,
EXPOSED TO VIEW IN FINISHED AREAS UNLESS OTHERWISE
RENOVATION
F CPT-01 F CPT-01 F CPT-01 F CPT-01 INDICATED.
F CPT-01 D. PAINT EXISTING FIRE EXTINGUISHER CABINETS, METAL
ACCESS PANELS, LOUVERS, UNIT VENTILATORS, AND
5500 Wabash Avenue
OTHER PAINTABLE SURFACES IN ROOMS TO BE FINISHED
UNLESS OTHERWISE INDICATED.
E. FINISH SOFFITS, BULKHEADS, AND SIMILAR CONDITIONS TO
Terre Haute, Indiana
CORRIDOR

08-G1
ADMIN OFFICE
FL116
FL120
W PT-03
MATCH SURROUNDING SURFACES UNLESS OTHERWISE
INDICATED.
47803
W PT-02 CG-01 CG-01 B RB-01 CG-01 CG-01 F. IN STAIRWELLS, PAINT STEEL STAIR AND LANDING PARTS
09-N1
B RB-01 F CPT-03 CG-01 EXPOSED TO VIEW INCLUDING RISERS AND TREADS, Owner
F CPT-01 STRINGERS, UNDERSIDE OF STAIR STRUCTURE,
HANDRAILS, WALL BRACKETS, COMPONENTS VISIBLE FROM
Rose-Hulman Institute of Technology
EXTERIOR, ETC., UNLESS OTHERWISE INDICATED. 5500 Wabash Avenue
FACULTY G. DO NOT APPLY FINISHES BEHIND FIXED EQUIPMENT SUCH Terre Haute, Indiana 47803
FACULTY OFFICE COLLISION AS CABINETRY, CASEWORK, CHALK AND TACKBOARDS, 812-877-1511
FACULTY OFFICE FACULTY OFFICEFACULTY OFFICE
FACULTY OFFICE
FL112 FL108 LOCKERS, ETC.
08-G1 FL114 FL106 FL104 FL102
W PT-02 W PT-03 H. ALIGN FLOOR FINISH TRANSITIONS AT DOOR LOCATIONS
09-N1 W PT-02 W PT-02 W PT-02 W PT-02 WITH CENTERLINE OF DOOR SUCH THAT TRANSITION
CG-01 B RB-01 B RB-01 B RB-01 B RB-01 B RB-01
B RB-01 F CPT-01 F LVT-01 MATERIALS ARE NOT VISIBLE FROM EITHER SIDE WHEN
F CPT-01 F CPT-01 F CPT-01 F CPT-01
DOOR IS IN CLOSED POSITION. TRANSITIONS MUST BE 1/8"
ZINC TERRAZZO STRIP WITH LEVELING LATEX USED AS
REQUIRED TO INSURE SURFACES ARE LEVEL.
I. REFER TO REFLECTED CEILING PLANS AND INTERIOR
PT-03 CG-01 CG-01 ELEVATIONS FOR ADDITIONAL FINISH INFORMATION.
CG-01 J. REFER TO PROJECT MANUAL DIVISION 9 FOR FINISH LEVEL
CPT-03 REQUIREMENTS FOR GYPSUM BOARD SURFACES UNLESS
RB-01 OTHERWISE INDICATED. Architect
CG-01 K. REFERENCE FINISH PLANS FOR CORNER GUARD

EQ
PT-03 CENTER CARPET CORRIDOR LOCATIONS AND PREP CORNER AS NEEDED. RATIO
CG-01 ACROSS CORRIDOR FL120 L. PROVIDE SOLID SURFACE WINDOW SILL SSM-02 AT NEW 101 South Pennsylvania Street
WIDTH W PT-03 OPENINGS. MILLWORKER MUST PROVIDE DETAIL FOR FINAL Indianapolis, Indiana 46204
B RB-01 APPROVAL PRIOR TO FABRICATION. 317-633-4040

EQ
CG-01 F CPT-03 CG-01 M. EXPOSED BRICK TO BE CLEANED AND PAINTED PT-01.
A5 / A-650 N. ALL WALLS WITH PT-04, PT-05, PT-06 INDICATED AS FINISH
ARE TO RECEIVE LEVEL 5 DRYWALL FINISH,
O. REFERENCE ALL DEMOLITION AND ARCHITECTURAL PLANS Structural Engineer
FOR AREAS SHOWN WITH SHAFT WORK. THESE AFFECTED Fink Roberts & Petrie, Inc.
WALLS WILL REQUIRED PAINTING FROM CORNER TO
PT-07 CTB-02 KITCHEN CORNER.NOT ALL LOCATIONS ARE VISIBLE IN FINISH PLANS. 9449 Priority Way W Dr #200
EL125 P. REFERENCE ALL DEMOLITION PLANS FOR REMOVAL OF Indianapolis, Indiana 46240
CPT-03
W FRP-01 PERIMETER DRYWALL BULKHEADS. ALL ADJACENT WALLS 317-872-8400

CT-04
CG-01 B QTB-01 WILL REQUIRE PAINTING FROM CORNER TO CORNER. NOT
CAFE F QT-01 ALL LOCATIONS ARE VISIBLE IN FINISH PLANS.
EL127 HOUSEKEEPING

DW
W PT-07 EQUIPMENT Mechanical / Electrical Engineer
B RB-01 F5 ROOM CPT CON
4'-11" CT-03 F QT-01 A-402 ELEV 1 EL102
R.E. Dimond & Associates, Inc.
FULL TILE STORAGE - W PT-07 732 N Capitol Avenue
EL126 W ETR B RB-01 Indianapolis, Indiana 46204
W FRP-01 B ETR F SC-01
PT-05 F ETR 317-634-4672
B QTB-01
ALIGN F QT-01 CON VINYL
CT-04
C5 / A-650 C6 / A-650
CTB-01

2 FULL TILES
45.
MAIL SORT

00°
LOUNGE EL103
C1 CT-01 W PT-07
A-152.2
EL112 A5 / A-650 CG-01
W PT-07 B RB-01 CPT CPT
B RB-02 ALIGN CG-01 F VCT-01
00°
45. F CT-01
7" CT-04
ALIGN CORRIDOR
A5 / A-650 CG-01 CG-01
--
PT-06 CT-02 W PT-03 CT VINYL
CT-04

PT-05 PT-05 B RB-01


RB-02 F CPT-03 A5 / A-650 A1 / A-650
CPT-02
CT-01
A5 / A-650 CG-01
CG-01

CT-04
ALTERNATE A-5 ALTERNATE A-5
B2
A-152.2 Room name
XXXXX
W Wall Fin ROOM NAME AND
45. A5 / A-650 A5 / A-650 B Base Fin ROOM FINISHES
00°
CT-04 EQ EQ F Floor Fin

FULL TILE
150 SF

4'-11"
45.

2'-0"
00°

CTB-01 RB-02 XX-01 FLOORING MATERIAL


TRANSITION

F
59" FULL TILE
FLOORING DIRECTION
3 G

INSTALL THESE
E
2
FULL TILES FIRST ACCENT WALL FINISH
PT-XX D
DESIGNATION
45.

C
59" FULL TILE
00°

ALIGN EACH
PLANK AT MITRE
EXISTING CARPET B 1
INSTALLED OVER THE
SUMMER, N.I.C. A
3 1/2"

KEY PLAN
3 3/8"
SEAL | DATE 04/01/21
59" FULL TILE

AREA N.I.C.

EXISTING BUILDING
INSTALL THESE QUARRY TILE, N.I.C.
FULL TILES FIRST

00°
45.

KEYNOTE LEGEND SHEET ISSUE


1 Construction Documents 04/01/21

C1 ENLARGED FINISH PLAN - TILE TRANSITION 08-G1 PROVIDE SOLID SURFACE WINDOW SILL AT NEW
OPENINGS WITH SSM-02. MILLWORKER MUST
A-152.2
3/8" = 1'-0" PROVIDE DETAIL FOR FINAL APPROVAL.
09-N1 WHERE FLOOR MOUNTED HVAC UNITS EXIST,
EXTEND CARPET UNDER BASE OF UNIT, SUCH
THAT NO EXPOSED SUBFLOOR IS VISIBLE FROM
ANY LOCATION IN THE ROOM. PROVIDE RUBBER
BASE AS NEEDED WHERE CARPET MEETS
EXPOSED BRICK WALL.

CT-05 CTB-03

CT-05

CT-06
PT-03

CONTINUE BASE AND CT-05


WALL PATTERN USING SAME DETAIL
AND SIZING AS EXISTING. DESIGN
INTENT IS TO CREATE SEAMLESS
CONTINUATION.

B2 ENLARGED FINISH PLAN - MEN'S RESTROOM COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A-152.2 ALTERNATE A-5 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
1/4" = 1'-0"
PROJECT NO. 19010.000
SHEET TITLE

LOWER LEVEL 1
FINISH PLAN - AREA
2
4/1/2021 11:44:28 AM

SHEET NUMBER

1 LOWER LEVEL 1 - FINISH - AREA 2


A-152.2
A-152.2
1/8" = 1'-0"
GENERAL FINISH PLAN NOTES RHIT MOENCH
RENOVATION
A. THESE GENERAL NOTES APPLY TO SERIES A150 PLANS.
B. PAINT NEW AND EXISTING HOLLOW METAL DOORS, DOOR
FRAMES, AND LINTELS EXPOSED TO VIEW IN FINISHED
5500 Wabash Avenue
AREAS AND AT EXTERIOR LOCATIONS UNLESS OTHERWISE
INDICATED. Terre Haute, Indiana
C. PAINT STEEL COLUMNS, BEAMS, STRUCTURE, ETC.,
EXPOSED TO VIEW IN FINISHED AREAS UNLESS OTHERWISE
INDICATED.
47803
D. PAINT EXISTING FIRE EXTINGUISHER CABINETS, METAL
ACCESS PANELS, LOUVERS, UNIT VENTILATORS, AND Owner
OTHER PAINTABLE SURFACES IN ROOMS TO BE FINISHED Rose-Hulman Institute of Technology
UNLESS OTHERWISE INDICATED.
E. FINISH SOFFITS, BULKHEADS, AND SIMILAR CONDITIONS TO 5500 Wabash Avenue
MATCH SURROUNDING SURFACES UNLESS OTHERWISE Terre Haute, Indiana 47803

EQ.
INDICATED. 812-877-1511
F. IN STAIRWELLS, PAINT STEEL STAIR AND LANDING PARTS
EXPOSED TO VIEW INCLUDING RISERS AND TREADS,
STRINGERS, UNDERSIDE OF STAIR STRUCTURE,
HANDRAILS, WALL BRACKETS, COMPONENTS VISIBLE FROM
EXTERIOR, ETC., UNLESS OTHERWISE INDICATED.
G. DO NOT APPLY FINISHES BEHIND FIXED EQUIPMENT SUCH
AS CABINETRY, CASEWORK, CHALK AND TACKBOARDS,
CLASSROOM
LOCKERS, ETC.
G203
H. ALIGN FLOOR FINISH TRANSITIONS AT DOOR LOCATIONS
W PT-02 WITH CENTERLINE OF DOOR SUCH THAT TRANSITION
B RB-01
F CPT-04 MATERIALS ARE NOT VISIBLE FROM EITHER SIDE WHEN
DOOR IS IN CLOSED POSITION. TRANSITIONS MUST BE 1/8" Architect
ZINC TERRAZZO STRIP WITH LEVELING LATEX USED AS
EQ. EQ. REQUIRED TO INSURE SURFACES ARE LEVEL. RATIO
I. REFER TO REFLECTED CEILING PLANS AND INTERIOR 101 South Pennsylvania Street
ELEVATIONS FOR ADDITIONAL FINISH INFORMATION. Indianapolis, Indiana 46204
J. REFER TO PROJECT MANUAL DIVISION 9 FOR FINISH LEVEL 317-633-4040
REQUIREMENTS FOR GYPSUM BOARD SURFACES UNLESS

EQ.
OTHERWISE INDICATED.
K. REFERENCE FINISH PLANS FOR CORNER GUARD
LOCATIONS AND PREP CORNER AS NEEDED.
Structural Engineer
L. PROVIDE SOLID SURFACE WINDOW SILL SSM-02 AT NEW Fink Roberts & Petrie, Inc.
OPENINGS. MILLWORKER MUST PROVIDE DETAIL FOR FINAL
PT-03
APPROVAL PRIOR TO FABRICATION.
9449 Priority Way W Dr #200

A1/A-650
PT-XX Indianapolis, Indiana 46240
M. EXPOSED BRICK TO BE CLEANED AND PAINTED PT-01.
CPT-03 N. ALL WALLS WITH PT-04, PT-05, PT-06 INDICATED AS FINISH 317-872-8400
RB-01 ARE TO RECEIVE LEVEL 5 DRYWALL FINISH,
O. REFERENCE ALL DEMOLITION AND ARCHITECTURAL PLANS
PT-03 FOR AREAS SHOWN WITH SHAFT WORK. THESE AFFECTED
Mechanical / Electrical Engineer
WALLS WILL REQUIRED PAINTING FROM CORNER TO
CORNER.NOT ALL LOCATIONS ARE VISIBLE IN FINISH PLANS. R.E. Dimond & Associates, Inc.
P. REFERENCE ALL DEMOLITION PLANS FOR REMOVAL OF 732 N Capitol Avenue
PERIMETER DRYWALL BULKHEADS. ALL ADJACENT WALLS
WILL REQUIRE PAINTING FROM CORNER TO CORNER. NOT Indianapolis, Indiana 46204
STG. ALL LOCATIONS ARE VISIBLE IN FINISH PLANS. 317-634-4672
G210A
W PT-02
B RB-01
F CPT-04 CPT CON

CLASSROOM
G208 CON VINYL
W PT-02 STUDENT AREA
B RB-01 G210 C5 / A-650 C6 / A-650
F CPT-04 W PT-02
B RB-01
F CPT-04

CPT CPT

CT VINYL

A5 / A-650 A1 / A-650

Room name
XXXXX
W Wall Fin ROOM NAME AND
B Base Fin ROOM FINISHES
F Floor Fin
150 SF F
3 G
XX-01 FLOORING MATERIAL
TRANSITION
E
2
D
FLOORING DIRECTION
C

B 1
ACCENT WALL FINISH
PT-XX DESIGNATION A
1 LOWER LEVEL 1 - FINISH - AREA 3
A-152.3
1/8" = 1'-0"
KEY PLAN
EXISTING CARPET
INSTALLED OVER THE
SUMMER, N.I.C. SEAL | DATE 04/01/21

AREA N.I.C.

EXISTING BUILDING
QUARRY TILE, N.I.C. SHEET ISSUE
1 Construction Documents 04/01/21

KEYNOTE LEGEND

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

LOWER LEVEL 1
FINISH PLAN - AREA
3
4/1/2021 11:44:32 AM

SHEET NUMBER

A-152.3
08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 08-G1 GENERAL FINISH PLAN NOTES
08-G1
09-N1
09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1 09-N1

DEPT. HEAD
RHIT MOENCH
A. THESE GENERAL NOTES APPLY TO SERIES A150 PLANS.
FACULTY OFFICE
F137
W PT-02
FACULTY OFFICE FACULTY OFFICE
F135
W PT-02
F133
FACULTY OFFICEFACULTY OFFICE FACULTY OFFICEFACULTY OFFICEFACULTY OFFICE
F131 F129 F127 F125 F123 F121 F119
FACULTY OFFICEFACULTY OFFICE FACULTY OFFICE
FACULTY OFFICE FACULTY OFFICE
F117
W PT-02
F115 F113
FACULTY OFFICEFACULTY OFFICEFACULTY OFFICE
F111 F109 F107
F105A
W PT-02
B RB-01
B. PAINT NEW AND EXISTING HOLLOW METAL DOORS, DOOR
FRAMES, AND LINTELS EXPOSED TO VIEW IN FINISHED
AREAS AND AT EXTERIOR LOCATIONS UNLESS OTHERWISE
RENOVATION
W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02 W PT-02
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
B RB-01
F CPT-01
F CPT-01
INDICATED.
C. PAINT STEEL COLUMNS, BEAMS, STRUCTURE, ETC.,
5500 Wabash Avenue
EXPOSED TO VIEW IN FINISHED AREAS UNLESS OTHERWISE
INDICATED.
D. PAINT EXISTING FIRE EXTINGUISHER CABINETS, METAL
Terre Haute, Indiana
CORRIDOR
F132
ADMIN OFFICE
F105
ACCESS PANELS, LOUVERS, UNIT VENTILATORS, AND
OTHER PAINTABLE SURFACES IN ROOMS TO BE FINISHED 47803
CG-01 W PT-03 UNLESS OTHERWISE INDICATED.
CG-01 CG-01 CG-01 CG-01 CG-01 CG-01 CG-01 W PT-02 08-G1
B RB-01 B RB-01 E. FINISH SOFFITS, BULKHEADS, AND SIMILAR CONDITIONS TO Owner
F CPT-03 F CPT-01 09-N1 MATCH SURROUNDING SURFACES UNLESS OTHERWISE
INDICATED. Rose-Hulman Institute of Technology
F. IN STAIRWELLS, PAINT STEEL STAIR AND LANDING PARTS 5500 Wabash Avenue
FACULTY OFFICE FACULTY OFFICE
EXPOSED TO VIEW INCLUDING RISERS AND TREADS, Terre Haute, Indiana 47803
FACULTY STRINGERS, UNDERSIDE OF STAIR STRUCTURE, 812-877-1511
F132 F130 FACULTY OFFICEFACULTY OFFICE FACULTY OFFICE
FACULTY OFFICEFACULTY OFFICE FACULTY OFFICE
FACULTY OFFICE FACULTY OFFICE FACULTY OFFICE HANDRAILS, WALL BRACKETS, COMPONENTS VISIBLE FROM
W PT-02 W PT-02 FACULTY OFFICE COLLISION
F126 F124 F122 F120 DATA F112 F110 F108 F106 F103 EXTERIOR, ETC., UNLESS OTHERWISE INDICATED.
B RB-01 B RB-01 F128 F116 08-G1
F CPT-01 F CPT-01 W PT-02 W PT-02 W PT-02 W PT-02 F114 W PT-02 W PT-02 W PT-02 W PT-02 G. DO NOT APPLY FINISHES BEHIND FIXED EQUIPMENT SUCH
W PT-03 W PT-02 09-N1
W PT-02 B RB-01 B RB-01 B RB-01 B RB-01 B RB-01 B RB-01 B RB-01 B RB-01 B RB-01 AS CABINETRY, CASEWORK, CHALK AND TACKBOARDS,
B RB-01 W PT-01 F CPT-01 F CPT-01
B RB-01 F CPT-01 F CPT-01 F CPT-01 F CPT-01 B RB-01 F CPT-01 F CPT-01 F CPT-01 LOCKERS, ETC.
F CPT-01 F LVT-01
F SDT-01 H. ALIGN FLOOR FINISH TRANSITIONS AT DOOR LOCATIONS
WITH CENTERLINE OF DOOR SUCH THAT TRANSITION
MATERIALS ARE NOT VISIBLE FROM EITHER SIDE WHEN
CG-01 2'-0" DOOR IS IN CLOSED POSITION. TRANSITIONS MUST BE 1/8"
FACULTY OFFICE
JAN ZINC TERRAZZO STRIP WITH LEVELING LATEX USED AS
F101 08-G1
F100 REQUIRED TO INSURE SURFACES ARE LEVEL.

EQ.
W PT-01 09-N1
CG-01 B RB-01 W PT-01 I. REFER TO REFLECTED CEILING PLANS AND INTERIOR Architect
CG-01 F CPT-01 B RB-01 ELEVATIONS FOR ADDITIONAL FINISH INFORMATION.
CORRIDOR F SC-01 RATIO
J. REFER TO PROJECT MANUAL DIVISION 9 FOR FINISH LEVEL
CENTER CARPET F132
REQUIREMENTS FOR GYPSUM BOARD SURFACES UNLESS 101 South Pennsylvania Street
ACROSS CORRIDOR W PT-03 CG-01 OTHERWISE INDICATED.
B RB-01 Indianapolis, Indiana 46204
WIDTH K. REFERENCE FINISH PLANS FOR CORNER GUARD
F CPT-03 317-633-4040
LOCATIONS AND PREP CORNER AS NEEDED.
L. PROVIDE SOLID SURFACE WINDOW SILL SSM-02 AT NEW
OPENINGS. MILLWORKER MUST PROVIDE DETAIL FOR FINAL

EQ.
APPROVAL PRIOR TO FABRICATION. Structural Engineer
M. EXPOSED BRICK TO BE CLEANED AND PAINTED PT-01. Fink Roberts & Petrie, Inc.
N. ALL WALLS WITH PT-04, PT-05, PT-06 INDICATED AS FINISH
ARE TO RECEIVE LEVEL 5 DRYWALL FINISH, 9449 Priority Way W Dr #200
O. REFERENCE ALL DEMOLITION AND ARCHITECTURAL PLANS Indianapolis, Indiana 46240
FOR AREAS SHOWN WITH SHAFT WORK. THESE AFFECTED 317-872-8400
PT-03 WALLS WILL REQUIRED PAINTING FROM CORNER TO
PT-XX REFINISH RESTROOM CORNER.NOT ALL LOCATIONS ARE VISIBLE IN FINISH PLANS.
WALLS AS REQUIRED P. REFERENCE ALL DEMOLITION PLANS FOR REMOVAL OF
PERIMETER DRYWALL BULKHEADS. ALL ADJACENT WALLS Mechanical / Electrical Engineer
AFTER PATCHING OF TWO
WALLS AND REPLACEMENT WILL REQUIRE PAINTING FROM CORNER TO CORNER. NOT R.E. Dimond & Associates, Inc.
OF CEILING. ALL LOCATIONS ARE VISIBLE IN FINISH PLANS.
WALL FINISHES INDICATED 732 N Capitol Avenue
IN LL1 FINISH PLAN AND Indianapolis, Indiana 46204
ELEVATION PT-XX
317-634-4672
CPT CON
PT-XX
PAINT ALL WALLS AS
REQUIRED TO MATCH
EXISTING COLOR.
REPAINTING IS REQUIRED
AFTER REPLACEMENT OF CON VINYL
ALL BULKHEADS.
C5 / A-650 C6 / A-650

PT-03

PT-03
CPT CPT

ALTERNATE A-5
INCLUDES REMOVAL OF PEDESTALS CT VINYL
ALTERNATE A-5 AND ADDING PLATFORM TO MATCH
LL1 PLATFORM UNDER STAIRS A5 / A-650 A1 / A-650

Room name
XXXXX
W Wall Fin ROOM NAME AND
B Base Fin ROOM FINISHES
EXISTING WALL
F Floor Fin
FINISHES TO REMAIN
150 SF

XX-01 FLOORING MATERIAL


TRANSITION
F
3 G

PAINT WALLS AFTER FLOORING DIRECTION


E
2
BULKHEAD WORK
COMPLETE D

ACCENT WALL FINISH C


PT-XX DESIGNATION
PT-XX

PT-XX
B 1
A
EXISTING CARPET
INSTALLED OVER THE
SUMMER, N.I.C.
KEY PLAN

SEAL | DATE 04/01/21

AREA N.I.C.

EXISTING BUILDING
QUARRY TILE, N.I.C.

SHEET ISSUE
1 Construction Documents 04/01/21
KEYNOTE LEGEND
PT-XX

PT-XX 08-G1 PROVIDE SOLID SURFACE WINDOW SILL AT NEW


OPENINGS WITH SSM-02. MILLWORKER MUST
PROVIDE DETAIL FOR FINAL APPROVAL.
09-N1 WHERE FLOOR MOUNTED HVAC UNITS EXIST,
EXTEND CARPET UNDER BASE OF UNIT, SUCH
PT-XX THAT NO EXPOSED SUBFLOOR IS VISIBLE FROM
ANY LOCATION IN THE ROOM. PROVIDE RUBBER
BASE AS NEEDED WHERE CARPET MEETS
EXPOSED BRICK WALL.

PT-XX

PT-XX

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


PT-XX AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
PT-03 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
ALTERNATE A-5
PROJECT NO. 19010.000
SHEET TITLE

FIRST LEVEL FINISH


PLAN - AREA 2
4/1/2021 11:44:38 AM

PT-03
SHEET NUMBER
1 FIRST LEVEL FINISH - AREA 2
A-153.2
1/8" = 1'-0" A-153.2
GENERAL FINISH PLAN NOTES
RHIT MOENCH
A. THESE GENERAL NOTES APPLY TO SERIES A150 PLANS.
RENOVATION
B. PAINT NEW AND EXISTING HOLLOW METAL DOORS, DOOR
FRAMES, AND LINTELS EXPOSED TO VIEW IN FINISHED
AREAS AND AT EXTERIOR LOCATIONS UNLESS OTHERWISE
5500 Wabash Avenue
INDICATED.
C. PAINT STEEL COLUMNS, BEAMS, STRUCTURE, ETC., Terre Haute, Indiana
EXPOSED TO VIEW IN FINISHED AREAS UNLESS OTHERWISE
INDICATED.
D. PAINT EXISTING FIRE EXTINGUISHER CABINETS, METAL
47803
ACCESS PANELS, LOUVERS, UNIT VENTILATORS, AND
OTHER PAINTABLE SURFACES IN ROOMS TO BE FINISHED Owner
UNLESS OTHERWISE INDICATED. Rose-Hulman Institute of Technology
E. FINISH SOFFITS, BULKHEADS, AND SIMILAR CONDITIONS TO
MATCH SURROUNDING SURFACES UNLESS OTHERWISE 5500 Wabash Avenue
INDICATED. Terre Haute, Indiana 47803
F. IN STAIRWELLS, PAINT STEEL STAIR AND LANDING PARTS 812-877-1511
EXPOSED TO VIEW INCLUDING RISERS AND TREADS,
STRINGERS, UNDERSIDE OF STAIR STRUCTURE,
HANDRAILS, WALL BRACKETS, COMPONENTS VISIBLE FROM
EXTERIOR, ETC., UNLESS OTHERWISE INDICATED.
G. DO NOT APPLY FINISHES BEHIND FIXED EQUIPMENT SUCH
AS CABINETRY, CASEWORK, CHALK AND TACKBOARDS,
LOCKERS, ETC.
H. ALIGN FLOOR FINISH TRANSITIONS AT DOOR LOCATIONS
WITH CENTERLINE OF DOOR SUCH THAT TRANSITION
MATERIALS ARE NOT VISIBLE FROM EITHER SIDE WHEN
DOOR IS IN CLOSED POSITION. TRANSITIONS MUST BE 1/8"
ZINC TERRAZZO STRIP WITH LEVELING LATEX USED AS Architect
REQUIRED TO INSURE SURFACES ARE LEVEL.
I. REFER TO REFLECTED CEILING PLANS AND INTERIOR RATIO
ELEVATIONS FOR ADDITIONAL FINISH INFORMATION. 101 South Pennsylvania Street
J. REFER TO PROJECT MANUAL DIVISION 9 FOR FINISH LEVEL Indianapolis, Indiana 46204
REQUIREMENTS FOR GYPSUM BOARD SURFACES UNLESS 317-633-4040
OTHERWISE INDICATED.
K. REFERENCE FINISH PLANS FOR CORNER GUARD
LOCATIONS AND PREP CORNER AS NEEDED.
L. PROVIDE SOLID SURFACE WINDOW SILL SSM-02 AT NEW
Structural Engineer
OPENINGS. MILLWORKER MUST PROVIDE DETAIL FOR FINAL Fink Roberts & Petrie, Inc.
APPROVAL PRIOR TO FABRICATION.
9449 Priority Way W Dr #200
M. EXPOSED BRICK TO BE CLEANED AND PAINTED PT-01.
N. ALL WALLS WITH PT-04, PT-05, PT-06 INDICATED AS FINISH Indianapolis, Indiana 46240
ARE TO RECEIVE LEVEL 5 DRYWALL FINISH, 317-872-8400
O. REFERENCE ALL DEMOLITION AND ARCHITECTURAL PLANS
FOR AREAS SHOWN WITH SHAFT WORK. THESE AFFECTED
EQ EQ EQ EQ WALLS WILL REQUIRED PAINTING FROM CORNER TO Mechanical / Electrical Engineer
CORNER.NOT ALL LOCATIONS ARE VISIBLE IN FINISH PLANS.
P. REFERENCE ALL DEMOLITION PLANS FOR REMOVAL OF R.E. Dimond & Associates, Inc.
PERIMETER DRYWALL BULKHEADS. ALL ADJACENT WALLS 732 N Capitol Avenue
WILL REQUIRE PAINTING FROM CORNER TO CORNER. NOT
CLASSROOM
STUDENT WORK
ALL LOCATIONS ARE VISIBLE IN FINISH PLANS.
Indianapolis, Indiana 46204
CLASSROOM AREA 317-634-4672
G308
G306 G304
W PT-02
B RB-01 W PT-02 W PT-02
F CPT-04 B RB-01 ROOF ACCESS B RB-01
F CPT-04 F CPT-04 CPT CON
G304B
W PT-02 CLOSET
B RB-01 G304A
F SC-01 W PT-02
CG-01 B RB-01
F CPT-04
CON VINYL

C5 / A-650 C6 / A-650

CPT CPT

PT-XX

CT VINYL

A5 / A-650 A1 / A-650

Room name
XXXXX F
13 SEAT CONF.
W Wall Fin
B Base Fin
ROOM NAME AND
ROOM FINISHES
3 G

G305
W PT-02
STORAGE
F Floor Fin
150 SF
E
2
G305A
B RB-01 W PT-02 D
F CPT-04 XX-01 FLOORING MATERIAL
B RB-01
F CPT-04 TRANSITION
C

FLOORING DIRECTION
B 1
A

ACCENT WALL FINISH


PT-XX DESIGNATION KEY PLAN

SEAL | DATE 04/01/21

EXISTING CARPET
INSTALLED OVER THE
SUMMER, N.I.C.

AREA N.I.C.

1 FIRST LEVEL FINISH - AREA 3 SHEET ISSUE


A-153.3
1/8" = 1'-0"
1 Construction Documents 04/01/21
EXISTING BUILDING
QUARRY TILE, N.I.C.

KEYNOTE LEGEND

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

FIRST LEVEL FINISH


PLAN - AREA 3
4/1/2021 11:44:42 AM

SHEET NUMBER

A-153.3
GENERAL FINISH PLAN NOTES
RHIT MOENCH
PT-XX
A. THESE GENERAL NOTES APPLY TO SERIES A150 PLANS.
B. PAINT NEW AND EXISTING HOLLOW METAL DOORS, DOOR
FRAMES, AND LINTELS EXPOSED TO VIEW IN FINISHED
RENOVATION
PT-03
RB-01 PT-XX
AREAS AND AT EXTERIOR LOCATIONS UNLESS OTHERWISE
INDICATED.
5500 Wabash Avenue
PT-XX
C. PAINT STEEL COLUMNS, BEAMS, STRUCTURE, ETC.,
EXPOSED TO VIEW IN FINISHED AREAS UNLESS OTHERWISE
INDICATED.
Terre Haute, Indiana
PT-XX PT-03
D. PAINT EXISTING FIRE EXTINGUISHER CABINETS, METAL
ACCESS PANELS, LOUVERS, UNIT VENTILATORS, AND 47803
RB-01 OTHER PAINTABLE SURFACES IN ROOMS TO BE FINISHED
PT-XX UNLESS OTHERWISE INDICATED. Owner
E. FINISH SOFFITS, BULKHEADS, AND SIMILAR CONDITIONS TO
MATCH SURROUNDING SURFACES UNLESS OTHERWISE
Rose-Hulman Institute of Technology
INDICATED. 5500 Wabash Avenue
F. IN STAIRWELLS, PAINT STEEL STAIR AND LANDING PARTS Terre Haute, Indiana 47803
EXPOSED TO VIEW INCLUDING RISERS AND TREADS, 812-877-1511
PT-XX PT-XX PT-XX STRINGERS, UNDERSIDE OF STAIR STRUCTURE,
PT-03 HANDRAILS, WALL BRACKETS, COMPONENTS VISIBLE FROM
PT-03 ALTERNATE A-5 PT-03
RB-01 EXTERIOR, ETC., UNLESS OTHERWISE INDICATED.
G. DO NOT APPLY FINISHES BEHIND FIXED EQUIPMENT SUCH
AS CABINETRY, CASEWORK, CHALK AND TACKBOARDS,
LOCKERS, ETC.
PT-03 PT-03
H. ALIGN FLOOR FINISH TRANSITIONS AT DOOR LOCATIONS
WITH CENTERLINE OF DOOR SUCH THAT TRANSITION
MATERIALS ARE NOT VISIBLE FROM EITHER SIDE WHEN
DOOR IS IN CLOSED POSITION. TRANSITIONS MUST BE 1/8"
PT-03 ZINC TERRAZZO STRIP WITH LEVELING LATEX USED AS
PT-03 PT-XX REQUIRED TO INSURE SURFACES ARE LEVEL.
PT-XX Architect
PT-XX I. REFER TO REFLECTED CEILING PLANS AND INTERIOR
ELEVATIONS FOR ADDITIONAL FINISH INFORMATION. RATIO
J. REFER TO PROJECT MANUAL DIVISION 9 FOR FINISH LEVEL 101 South Pennsylvania Street
REQUIREMENTS FOR GYPSUM BOARD SURFACES UNLESS Indianapolis, Indiana 46204
PT-03 OTHERWISE INDICATED. 317-633-4040
RB-01 K. REFERENCE FINISH PLANS FOR CORNER GUARD
LOCATIONS AND PREP CORNER AS NEEDED.
L. PROVIDE SOLID SURFACE WINDOW SILL SSM-02 AT NEW
OPENINGS. MILLWORKER MUST PROVIDE DETAIL FOR FINAL Structural Engineer
APPROVAL PRIOR TO FABRICATION. Fink Roberts & Petrie, Inc.
M. EXPOSED BRICK TO BE CLEANED AND PAINTED PT-01.
N. ALL WALLS WITH PT-04, PT-05, PT-06 INDICATED AS FINISH 9449 Priority Way W Dr #200
ARE TO RECEIVE LEVEL 5 DRYWALL FINISH, Indianapolis, Indiana 46240
O. REFERENCE ALL DEMOLITION AND ARCHITECTURAL PLANS 317-872-8400
FOR AREAS SHOWN WITH SHAFT WORK. THESE AFFECTED
WALLS WILL REQUIRED PAINTING FROM CORNER TO
CORNER.NOT ALL LOCATIONS ARE VISIBLE IN FINISH PLANS.
P. REFERENCE ALL DEMOLITION PLANS FOR REMOVAL OF Mechanical / Electrical Engineer
PERIMETER DRYWALL BULKHEADS. ALL ADJACENT WALLS R.E. Dimond & Associates, Inc.
PT-03 WILL REQUIRE PAINTING FROM CORNER TO CORNER. NOT
RB-01
PT-XX ALL LOCATIONS ARE VISIBLE IN FINISH PLANS. 732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672
CPT CON

PT-03
PT-XX RB-01
PT-XX
CON VINYL
ALTERNATE A-5
C5 / A-650 C6 / A-650

PT-03
RB-01
CPT CPT

CT VINYL
PT-03
RB-01 PT-XX A5 / A-650 A1 / A-650

Room name
PT-03 XXXXX
W Wall Fin ROOM NAME AND
RB-01 ROOM FINISHES
B Base Fin
F Floor Fin
150 SF
THESE WALLS SHOULD PT-XX
NOT REQUIRE PAINT
XX-01 FLOORING MATERIAL
PT-XX TRANSITION F
3 G

FLOORING DIRECTION
E
2
D
PT-03
RB-01 ACCENT WALL FINISH
C
PAINT ALL WALLS AS PT-XX
REQUIRED TO MATCH DESIGNATION
EXISTING COLOR.
REPAINTING REQUIRED
B 1
AFTER BULKHEADS ARE
REBUILT AFTER HVAC WORK.
A
EXISTING CARPET
INSTALLED OVER THE
SUMMER, N.I.C. KEY PLAN

SEAL | DATE 04/01/21

PT-03 ALTERNATE A-5


RB-01
AREA N.I.C.

PT-03
RB-01
PT-XX
EXISTING BUILDING
QUARRY TILE, N.I.C.

SHEET ISSUE
CPT-01 PT-03 1 Construction Documents 04/01/21

ALIGN EXISTING AND


NEW CARPET PATTERN
INSTALLATIONS

SITTING AREA PT-XX KEYNOTE LEGEND


A220
CPT-01 W PT-03
B RB-01
F CPT-03

2'-0"

ALIGN EXISTING AND


PT-XX NEW CARPET PATTERN
INSTALLATIONS

PT-XX

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

SECOND LEVEL
FINISH PLAN - AREA
1
4/1/2021 12:07:56 PM

1 SECOND LEVEL FINISH - AREA 1


A-154.1 SHEET NUMBER
1/8" = 1'-0"

A-154.1
GENERAL FINISH PLAN NOTES
RHIT MOENCH
A. THESE GENERAL NOTES APPLY TO SERIES A150 PLANS.
B. PAINT NEW AND EXISTING HOLLOW METAL DOORS, DOOR
FRAMES, AND LINTELS EXPOSED TO VIEW IN FINISHED
RENOVATION
AREAS AND AT EXTERIOR LOCATIONS UNLESS OTHERWISE
INDICATED. 5500 Wabash Avenue
C. PAINT STEEL COLUMNS, BEAMS, STRUCTURE, ETC.,
EXPOSED TO VIEW IN FINISHED AREAS UNLESS OTHERWISE
INDICATED.
Terre Haute, Indiana
D. PAINT EXISTING FIRE EXTINGUISHER CABINETS, METAL
ACCESS PANELS, LOUVERS, UNIT VENTILATORS, AND 47803
OTHER PAINTABLE SURFACES IN ROOMS TO BE FINISHED
UNLESS OTHERWISE INDICATED. Owner
E. FINISH SOFFITS, BULKHEADS, AND SIMILAR CONDITIONS TO
MATCH SURROUNDING SURFACES UNLESS OTHERWISE Rose-Hulman Institute of Technology
INDICATED. 5500 Wabash Avenue
F. IN STAIRWELLS, PAINT STEEL STAIR AND LANDING PARTS Terre Haute, Indiana 47803
EXPOSED TO VIEW INCLUDING RISERS AND TREADS, 812-877-1511
STRINGERS, UNDERSIDE OF STAIR STRUCTURE,
HANDRAILS, WALL BRACKETS, COMPONENTS VISIBLE FROM
EXTERIOR, ETC., UNLESS OTHERWISE INDICATED.
G. DO NOT APPLY FINISHES BEHIND FIXED EQUIPMENT SUCH
AS CABINETRY, CASEWORK, CHALK AND TACKBOARDS,
LOCKERS, ETC.
H. ALIGN FLOOR FINISH TRANSITIONS AT DOOR LOCATIONS
WITH CENTERLINE OF DOOR SUCH THAT TRANSITION
MATERIALS ARE NOT VISIBLE FROM EITHER SIDE WHEN
DOOR IS IN CLOSED POSITION. TRANSITIONS MUST BE 1/8"
ZINC TERRAZZO STRIP WITH LEVELING LATEX USED AS
REQUIRED TO INSURE SURFACES ARE LEVEL.
Architect
I. REFER TO REFLECTED CEILING PLANS AND INTERIOR
ELEVATIONS FOR ADDITIONAL FINISH INFORMATION. RATIO
J. REFER TO PROJECT MANUAL DIVISION 9 FOR FINISH LEVEL 101 South Pennsylvania Street
REQUIREMENTS FOR GYPSUM BOARD SURFACES UNLESS
REFINISH RESTROOM Indianapolis, Indiana 46204
OTHERWISE INDICATED.
WALLS AS REQUIRED K. REFERENCE FINISH PLANS FOR CORNER GUARD 317-633-4040
AFTER PATCHING OF TWO LOCATIONS AND PREP CORNER AS NEEDED.
WALLS AND REPLACEMENT L. PROVIDE SOLID SURFACE WINDOW SILL SSM-02 AT NEW
OF CEILING. OPENINGS. MILLWORKER MUST PROVIDE DETAIL FOR FINAL Structural Engineer
APPROVAL PRIOR TO FABRICATION. Fink Roberts & Petrie, Inc.
M. EXPOSED BRICK TO BE CLEANED AND PAINTED PT-01.
N. ALL WALLS WITH PT-04, PT-05, PT-06 INDICATED AS FINISH 9449 Priority Way W Dr #200
ARE TO RECEIVE LEVEL 5 DRYWALL FINISH, Indianapolis, Indiana 46240
A1 / A-650 O. REFERENCE ALL DEMOLITION AND ARCHITECTURAL PLANS 317-872-8400
FOR AREAS SHOWN WITH SHAFT WORK. THESE AFFECTED
CT-05 WALLS WILL REQUIRED PAINTING FROM CORNER TO
PT-03
RB-01 CORNER.NOT ALL LOCATIONS ARE VISIBLE IN FINISH PLANS.
PT-XX Mechanical / Electrical Engineer
P. REFERENCE ALL DEMOLITION PLANS FOR REMOVAL OF
PERIMETER DRYWALL BULKHEADS. ALL ADJACENT WALLS R.E. Dimond & Associates, Inc.
PT-03 WILL REQUIRE PAINTING FROM CORNER TO CORNER. NOT
RB-01 ALL LOCATIONS ARE VISIBLE IN FINISH PLANS. 732 N Capitol Avenue
Indianapolis, Indiana 46204
CT-05 317-634-4672

CPT CON
PT-03
RB-01 PAINT ALL WALLS AS
CPT-01 REQUIRED TO MATCH
EXISTING COLOR.
CIRCULATION REPAINTING IS REQUIRED CON VINYL
- PAINT EXISTING RA-01 AFTER REPLACEMENT OF
W PT-03 HANDRAILS ALL BULKHEADS. C5 / A-650 C6 / A-650
CPT-01 B RB-01
F CPT-03
PT-XX
CPT CPT
PT-03
CPT-01

PT-03 QZ-01
RB-01 CT VINYL
ALTERNATE A-5 PT-03
A5 / A-650 A1 / A-650
PT-03 PAINT EXTG
HANDRAILS RA-01 CPT-03
SEATING
E200
W PT-03 PT-03
B RB-01 Room name
F CPT-03 XXXXX
W Wall Fin ROOM NAME AND
PT-03 QZ-01
B Base Fin ROOM FINISHES
F Floor Fin
150 SF
F
PT-XX
PT-XX 3 G
XX-01 FLOORING MATERIAL
TRANSITION
E
2
PT-XX D
PT-XX PT-XX FLOORING DIRECTION
PT-XX C

ACCENT WALL FINISH


B 1
PT-XX DESIGNATION A

PT-03 KEY PLAN


RB-01 EXISTING CARPET
INSTALLED OVER THE
SUMMER, N.I.C. SEAL | DATE 04/01/21

PT-XX

PT-XX

PT-XX
AREA N.I.C.

PT-XX PT-XX
PT-03
RB-01 PT-XX

EXISTING BUILDING
PT-XX PT-XX QUARRY TILE, N.I.C. SHEET ISSUE
PT-XX 1 Construction Documents 04/01/21

PT-XX
PT-XX

PT-03
RB-01
KEYNOTE LEGEND

PT-XX

PT-XX
PT-XX
PT-XX PT-XX

PT-XX
PT-03
RB-01 PT-XX

PT-XX

PT-XX PT-03
RB-01
PT-XX

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
PT-XX PT-XX PT-XX COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
PT-03
PT-03 ALTERNATE A-5 PT-03
PROJECT NO. 19010.000
RB-01
SHEET TITLE

PT-03 PT-03 SECOND LEVEL


FINISH PLAN - AREA
PT-03
PT-03
PT-XX 2
4/1/2021 12:07:58 PM

PT-XX
PT-XX

SHEET NUMBER
PT-03
RB-01

1
A-154.2
SECOND LEVEL FINISH - AREA 2 A-154.2
1/8" = 1'-0"
RHIT MOENCH
RENOVATION
FACULTY FACULTYFACULTYFACULTYFACULTYFACULTYFACULTY
FACULTY
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
5500 Wabash Avenue
FL115 FL113 FL111 FL109 FL107 FL105 FL103 FL101
FURNITURE SHOWN FOR Terre Haute, Indiana
REFERENCE ONLY. FINAL 47803
LAYOUT AND COORDINATION OF Owner
CLOSET DEPT. HEAD ELECTRICAL/ DATA MUST OCCUR Rose-Hulman Institute of Technology
G220A FL116B
CLASSROOM
G203 MENS R.R.
STUDY AREA
G204
DIRECTLY THROUGH FURNITURE 5500 Wabash Avenue
G206 Terre Haute, Indiana 47803
DEALERSHIP. 812-877-1511

5'-11"
CLASSROOM ADMIN OFFICE
G222 CLASSROOM FL116
G220
FACULTY
WOMENS R.R.
OFFICE
G202
FL114

FACULTY
COLLISION
FL108 Architect
STG.
G210A RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
CLASSROOM CLASSROOM HOUSEKEEPING

DW
G221 G219 EQUIPMENT
ELEV 1
- ROOM Structural Engineer
CLASSROOM EL102
Fink Roberts & Petrie, Inc.
G208
9449 Priority Way W Dr #200
LOUNGE MAIL SORT
Indianapolis, Indiana 46240
EL112 EL103
STUDENT 317-872-8400
COOK AREA
GREENHOUSE G210
G219A
Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
WOMENS R.R. MENS R.R.
Indianapolis, Indiana 46204
EL105 EL104
317-634-4672

SEMICONDUCTOR
OPTICS LAB
DL108
OFFICE
DL107
?
?
?

NUCLEAR
PHYSICS LAB OFFICE
DL105 DL106
OPTICAL
ENGINEERING
LAB 3 OPTICAL
DL115 METROLOGY
LAB OFFICE
DL104 DL103

OPTICAL
ENGINEERING
LAB 1 SENIOR OFFICE
DARK ROOM DESIGN LAB
DL117 DL102
G112 DL101

CLASSROOM
DL119
OPTICAL ACOUSTICS
ENGINEERING PROJECTS
LAB OFFICE
LAB 2 CL109
CL118 CL110

M.T.F.
MEASUREMENT NON-LINEAR CONFERENCE
LAB OPTICS LAB ROOM H BAR
CL114 CL115 CL116 EL108

OFFICE ADMIN OFFICE OFFICE


OFFICE CL108 CL106 CL105
CL107
PHYSICS LAB
3 SEAL | DATE 04/01/21
E.I.T.
CL117 CL102A
CLASSROOM
CL119 OPTICAL
COMMUNICATIONS OFFICE
ELECTRICAL CL104
ROOM STORAGE LAB
CL101 CL102B CL103

ENGINEERING OFFICE
PHYSICS LAB BL103 OFFICE
MATERIALS 1 BL102
PROCESSING BL110
PHYSICS LAB LAB
1 BL112 OFFICE
BL113 BL104 SHEET ISSUE
PHYSICS 1 Construction Documents 04/01/21
STOCK ROOM OFFICE OFFICE
BL108 BL109 OFFICE BL101
BL105

MACHINE
ELECTRICAL SHOP OFFICE OFFICE
ROOM BL107 BL106 BL100
PHYSICS LAB BL115
2
BL114 ELEV 2
CUSTODIAL -
STORAGE
BL116
OFFICE OFFICE OFFICE
AL104 AL103 AL102

ELEVATOR STORAGE
MECHANICAL ART CURATOR AL101A
BL117 AL101
WATER ROOM
AL106

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

LOWER LEVEL 1
FURNITURE PLAN
A5 LOWER LEVEL 1 FURNITURE PLAN
4/1/2021 11:45:06 AM

A-172
1/16" = 1'-0"

SHEET NUMBER

A-172
RHIT MOENCH
RENOVATION
FACULTYFACULTYFACULTYFACULTY
FACULTYFACULTYFACULTY FACULTYFACULTYFACULTYFACULTY
FACULTYFACULTYFACULTYFACULTY
FACULTY
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICEOFFICE OFFICE OFFICE OFFICEOFFICE
5500 Wabash Avenue
F137 F135 F133 F131 F129 F127 F125 F123 F121 F119 F117 F115 F113 F111 F109 F107
FURNITURE SHOWN FOR Terre Haute, Indiana
CLASSROOM CLASSROOM
STUDENT
WORK AREA DEPT. HEAD
REFERENCE ONLY. FINAL 47803
G308 G306 G304 F105A LAYOUT AND COORDINATION OF Owner
ELECTRICAL/ DATA MUST OCCUR Rose-Hulman Institute of Technology
DIRECTLY THROUGH FURNITURE 5500 Wabash Avenue

4'-5 1/8"
CLASSROOM Terre Haute, Indiana 47803
G310
ADMIN OFFICE
F105
DEALERSHIP. 812-877-1511
FACULTY
OFFICE
FACULTY 5'-0" F103
OFFICE DATA
JAN

8'-10"
CLOSET F132 F114
G304A F100

8'-10"
ROOF
ACCESS
G304B
FACULTY FACULTY
COLLISION OFFICE Architect
F116 F101 RATIO
101 South Pennsylvania Street
EQUIPMENT SERVER/EQUIP. Indianapolis, Indiana 46204
CLASSROOM CLASSROOM CLASSROOM REPAIR ROOM STORAGE 317-633-4040
G317 G315 G313 E107A E107C CLASSROOM
E104
ELEV 1
TECHNICIAN Structural Engineer
- WOMENS R.R.
STORAGE OFFICE
E109 Fink Roberts & Petrie, Inc.
G305A E107B
9449 Priority Way W Dr #200
WORKSHOP MENS R.R. Indianapolis, Indiana 46240
13 SEAT
CONF. E107 E108 317-872-8400
G305

Mechanical / Electrical Engineer


OFFICE
E102
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
OFFICE 317-634-4672
E101

OFFICE
REFERENCE OFFICE OFFICE
D113
ENERGY (CONFERENCE) D108 D107
CONVERSION ROOM
AND POWER CLASSROOM D110
SYSTEMS D112
LABORATORY OFFICE
OFFICE OFFICE OFFICE
D114 D106
D111-1 D111 D109

OFFICE
D105

OFFICE
ELECTRONIC D104
CALIBRATION
LABORATORY ECE LAB TECH
CIRCUITS LEARNING
LABORATORY D116 D117
CENTER DESIGN LAB OFFICE
D115 D101-A D101 D103
OFFICE
D118

STORAGE OFFICE
D115A D102

INSTRUMENT
ROOM OFFICE
EQUIPMENT C114 C110
WORKSHOP/STORAGE
STORAGE
C112
C115A

DIGITAL
ELECTRONIC
MECHATRONICS OFFICE
MICROCOMPUTER C111 C109
LABORATORY
C115
OFFICE
C108

DYNAMIC
SYSTEMS AND OFFICE MAIL ROOM
OFFICE
CONTROLS C118 C104
C117
LABORATORY
SEAL | DATE 04/01/21
C116
OFFICE ADMIN
SERVER WORKROOM / C103
ROOM BREAKROOM
OFFICE C103A OFFICE
B107B
C101A C105

ELECTRICAL
ELECTRICAL ROOM
ROOM B107
B107A STORAGE
B105A
CLASSROOM
B106 ADVANCED
STUDY AREA CIRCUIT
144 OFFICE LABORATORY SHEET ISSUE
B108B B105 1 Construction Documents 04/01/21
OFFICE
B108C
OFFICE E.I.T.
B108A B103C

TEST OFFICE
BUSINESS SOLDERING OFFICE
AND FINANCE ENGINEERING B103A
LAB LAB B101 OFFICE
CONFERENCE
B104 B102 B100
ROOM
OFFICE
B109
B103B

CUSTODIAL ELEV 2
STORAGE -
GM ROOM B110
B111

WORKROOM / OFFICE
OFFICE A105
OFFICE BREAKROOM
A140 SERVER A102B OFFICE
A102A
OFFICE OFFICE ROOM A103 OFFICE
OFFICE OFFICE ADMIN OFFICE
A136 A138 A100A A106
A124 A126 A102
WORKROOM / STORAGE
OFFICE A104B OFFICE
BREAKROOM
ELEC. A101 A107
A122
APPLICATIONS A118A
READING OFFICE STORAGE OFFICE ELEC. AND SAFE OFFICE
ROOM OFFICE
A128 A120B A118 STORAGE A104A A104
A130 A108
A101A
CIRCULATION ADMIN OFFICE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
STORAGE A120 A113
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A120A OFFICE COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
OFFICE A109
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
A121 PROJECT NO. 19010.000
A123 A125 A127 A129 A117 A116 A115 A114 A112 A111 A110
SHEET TITLE

FIRST LEVEL
FURNITURE PLAN
FIRST LEVEL FURNITURE PLAN
4/1/2021 11:45:21 AM

A5
A-173
1/16" = 1'-0"

SHEET NUMBER

A-173
RHIT MOENCH
RENOVATION
5500 Wabash Avenue
FURNITURE SHOWN FOR Terre Haute, Indiana
CONFERENCE
REFERENCE ONLY. FINAL 47803
ROOM OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE LAYOUT AND COORDINATION OF Owner
F230 F228 F226 F224 F222 F220 F218 F216 F214 F212 F210 ELECTRICAL/ DATA MUST OCCUR Rose-Hulman Institute of Technology
DIRECTLY THROUGH FURNITURE 5500 Wabash Avenue
CIRCULATION STORAGE Terre Haute, Indiana 47803
ADMIN OFFICE - F208 DEALERSHIP. 812-877-1511
F231 1224 SF
BREAK AREA
F207 OFFICE
USABILITY
WORKROOM / LAB F206
BREAKROOM F225A OFFICE
F233
USABILITY CSSE LAB CSSE LAB F205
LAB CONTROL F225 F217 OFFICE
ROOM F204
F225B
STAIRWELL
- CUSTODIAL OFFICE
275 SF - F203 Architect
RATIO
101 South Pennsylvania Street
CIRCULATION
Indianapolis, Indiana 46204
MECHANICAL -
545 SF 317-633-4040
ROOM CLASSROOM
G116 E104
ELEV 1 WOMENS R.R.
- E202 Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
MECHANICAL Indianapolis, Indiana 46240
ROOM 317-872-8400
E201

Mechanical / Electrical Engineer


CIRCULATION
- R.E. Dimond & Associates, Inc.
1838 SF 732 N Capitol Avenue
SEATING
Indianapolis, Indiana 46204
E200
448 SF 317-634-4672

CIRCULATION
STORAGE OFFICE
OFFICE
D223A- D208
D222 131 SF

OFFICE OFFICE OFFICE OFFICE


OFFICE D220 D221 D209 OFFICE
D224
D223 D207

CIRCULATION
OFFICE STORAGE - STUDENT OFFICE
D225 CONFERENCE D206
D226A
138 SF STUDY AREA
D219A
OFFICE 134 SF D210
263 SF OFFICE
OFFICE D227
D226 D205

STORAGE / OFFICE OFFICE


WORKROOM D218 D204
OFFICE D226C 137 SF OFFICE
D228 ADMIN OFFICE D211
D229 134 SF OFFICE
D203

CIRCULATION FACULTY
OFFICE OFFICE OFFICE
- CONFERENCE
D230 D202
138 SF D215B ROOM CIRCULATION
145 SF
D212 -
OFFICE 287 SF 836 SF
OFFICE
OFFICE D232 D201
D231 STORAGE
D226D

MECHANICAL OFFICE
ROOM MECHANICAL C211
ROOM OFFICE
C215
C214 C212
OFFICE
C210

IT CLOSET
C200B OFFICE
STAFF C209
STUDY AREA RESOURCES
- CIRCULATION
OPEN TO C200
- BELOW OFFICE
5103 SF
STORAGE C208
C200A
CIRCULATION

62 SF
OFFICE
C216 OFFICE
C217

SEAL | DATE 04/01/21


MECHANICAL MECHANICAL ADMIN
ROOM ROOM C205 OFFICE
C218 C201 C206

W9NAA ROSE STORAGE


MECHANICAL
TECH RADIO
ROOM C205B
CLUB
MECHANICAL B202
B204
ROOM
B203 ADVANCED
PROJECTION CIRCUIT
ROOM STUDENT LABORATORY SHEET ISSUE
B111A CONFERENCE BBE HIVE OFFICE B105 1 Construction Documents 04/01/21
ROOM B201 1278 SF
B205
B205A
CIRCULATION STAIR
- 300-1
111 SF
32 SF
SYNTHETIC DIGITAL
BIOLOGY SIGNAL
LABORATORY PROCESSING
B206 LAB
B200

ELEV 2
GM ROOM -
MECHANICAL
B111 ROOM
B207
CIRCULATION
-
80 SF
CUSTODIAL
CIRCULATION MECHANICAL
STORAGE
- ROOM CLASSROOM
OFFICE A223A
ADMIN OFFICE 151 SF MENS R.R. A301
A218A A202
A218 A223
WOMENS R.R. CIRCULATION
- STORAGE /
A222
92 SF PROJECTOR
A202A
ELECTRICAL
OFFICE OFFICE BREAKROOM ROOM OFFICE
A218C A218B A200 A200A A201
OFFICE
WORK AREA /
CIRCULATION A203A
STORAGE
- A203
1304 SF CIRCULATIONOFFICE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
- A203B AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
58 SF DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
WORKROOM COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
OFFICE A207 OFFICE OFFICE OFFICE
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE A209 OFFICE A203D
A217 A216 A215 A214 A213 A212 A211 A210 ADMIN OFFICE A206 A205 A204 OFFICE PROJECT NO. 19010.000
A208 A203C
SHEET TITLE

SECOND LEVEL
FURNITURE PLAN
A5 SECOND LEVEL FURNITURE PLAN
4/1/2021 11:45:35 AM

A-174
1/16" = 1'-0"

SHEET NUMBER

A-174
GLAZING SCHEDULE NOTE: ALL EXISTING CONDITIONS AND OPENING
DIMENSIONS SHOWN FOR REFERENCE ONLY.
FINAL DIMENSIONS TO BE VERIFIED IN THE FIELD.
GL-01 CLEAR INSULATING GLASS, LOW-E COATED - EXTERIOR
APPLICATIONS
GL-02 CERAMIC COATED SPANDREL GLASS - EXTERIOR
APPLICATIONS
EXTERIOR ELEVATION NOTES
RHIT MOENCH
GL-03 INSULATING, CERAMIC COATED VISION GLASS -
EXTERIOR APPLICATIONS
GL-04 CLEAR INSULATING GLASS, LOW-E COATED, LAMINATED
01 NEW CURTAIN WALL FRAMED WINDOW
TO MATCH EXISTING WINDOWS IN KIND,
FLASH INTO EXISITNG CONSTRUCTION
RENOVATION
- EXTERIOR APPLICATIONS, FIRE RATED 03 NEW METAL PANEL WALL
GL-11 CLEAR TEMPERED GLASS - INTERIOR APPLICATIONS,
WINDOWS AND DOORS
CONSTRUCTION WITH RIGID
INSULATION OVER METAL STUDS
5500 Wabash Avenue
GL-12 DECORATIVE GLASS, FILM OVERLAY - INTERIOR
APPLICATIONS
04 NEW MECHANICAL LOUVER IN
EXISTING STOREFRONT OPENING,
Terre Haute, Indiana
COORDINATE WITH MECHANICAL
GL-13 CLEAR, LAMINATED - INTERIOR APPLICATIONS, FIRE
RATED DRAWINGS. 47803
GL-15 CLEAR TEMPERED LAMINATED GLASS - INTERIOR 05 INCREASE EXISTING MASONRY
APPLICATIONS, RAILINGS SEPARATION WALL UP AND AROUND Owner
NEW LIGHT MONITOR CONSTRUCTION.
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
E D C B A A B C D 317-633-4040

Structural Engineer
T/O NORTH GABLE T/O NORTH GABLE
163'-5 13/16" 163'-5 13/16" Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

T/O PARAPET T/O PARAPET


142'-8" 142'-8"

N SECOND LEVEL GL-01 TYP. N SECOND LEVEL


133'-6 13/16" 133'-6 13/16"

01 01 01 01

FIRST LEVEL FIRST LEVEL


120'-11 13/16" 120'-11 13/16"

01 01

LOWER LEVEL LOWER LEVEL


110'-7 1/16" 110'-7 1/16"

LOWER LEVEL 2 LOWER LEVEL 2


100'-0" 100'-0"

C3 EAST ELEVATION C6 WEST ELEVATION


A-201 A-201
1/8" = 1'-0" 1/8" = 1'-0"

SEAL | DATE 04/01/21

N1 N2 N3 N4 N5 N6 N7 N8 N9 N10

T/O NORTH GABLE


163'-5 13/16"

SHEET ISSUE
1 Construction Documents 04/01/21

T/O PARAPET
142'-8"

C7
TYP. A-622 GL-01 TYP. N SECOND LEVEL
133'-6 13/16"

01 01 01 01 01 01 01 01 01
A7
A-622

FIRST LEVEL
C5 120'-11 13/16"
TYP. A-622

04 01 01 01 01 01
A5
A-622
LOWER LEVEL
110'-7 1/16"
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE
LOWER LEVEL 2
100'-0" EXTERIOR
ELEVATIONS
4/1/2021 11:33:02 AM

A3 NORTH ELEVATION
A-201
1/8" = 1'-0"
SHEET NUMBER

A-201
GLAZING SCHEDULE NOTE: ALL EXISTING CONDITIONS AND OPENING
DIMENSIONS SHOWN FOR REFERENCE ONLY.
FINAL DIMENSIONS TO BE VERIFIED IN THE FIELD.
GL-01 CLEAR INSULATING GLASS, LOW-E COATED - EXTERIOR
APPLICATIONS
GL-02 CERAMIC COATED SPANDREL GLASS - EXTERIOR
APPLICATIONS
EXTERIOR ELEVATION NOTES
RHIT MOENCH
GL-03 INSULATING, CERAMIC COATED VISION GLASS -
EXTERIOR APPLICATIONS
GL-04 CLEAR INSULATING GLASS, LOW-E COATED, LAMINATED
01 NEW CURTAIN WALL FRAMED WINDOW
TO MATCH EXISTING WINDOWS IN KIND,
FLASH INTO EXISITNG CONSTRUCTION
RENOVATION
- EXTERIOR APPLICATIONS, FIRE RATED 03 NEW METAL PANEL WALL
GL-11 CLEAR TEMPERED GLASS - INTERIOR APPLICATIONS,
WINDOWS AND DOORS
CONSTRUCTION WITH RIGID
INSULATION OVER METAL STUDS
5500 Wabash Avenue
GL-12 DECORATIVE GLASS, FILM OVERLAY - INTERIOR
APPLICATIONS
04 NEW MECHANICAL LOUVER IN
EXISTING STOREFRONT OPENING,
Terre Haute, Indiana
COORDINATE WITH MECHANICAL
GL-13 CLEAR, LAMINATED - INTERIOR APPLICATIONS, FIRE
RATED DRAWINGS. 47803
GL-15 CLEAR TEMPERED LAMINATED GLASS - INTERIOR 05 INCREASE EXISTING MASONRY
APPLICATIONS, RAILINGS SEPARATION WALL UP AND AROUND Owner
NEW LIGHT MONITOR CONSTRUCTION.
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

E5
A-321
E1
A3 D3 A-321
A-322
A-322

GL-01 TYP. GL-01 TYP. GL-01 TYP. GL-01 TYP.

03 03 03 03

NORTH MONITOR- MID MONITOR- SOUTH MONITOR- SOUTH MONITOR-


D1 NORTH ELEV D2 NORTH ELEV D3 EAST/WEST ELEV D4 NORTH ELEV
A-202 A-202 A-202 A-202
1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0"

SEAL | DATE 04/01/21

D E F G H J K L M N O P Q R S T
A5 A3 A2
A-301 A-321 A-301
05
GL-01 TYP.

SHEET ISSUE
1 Construction Documents 04/01/21

B1 CENTRAL MONITOR WEST ELEVATION


A-202
1/8" = 1'-0"

A5
T E5 S R Q P O N M L K J A3 H G A-301 F E D
A-321 D6 A-321
18'-0" A-322 05
GL-01 TYP.

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

EXTERIOR
A1 CENTRAL MONITOR EAST ELEVATION ELEVATIONS
A-202
1/8" = 1'-0"
4/1/2021 11:33:08 AM

SHEET NUMBER

A-202
KEYNOTE LEGEND

RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

W V U T S R Q P O N M L K J H G F E D C B A

A5
A3 A-301
A2 A-321
A-301

N SECOND LEVEL
S SECOND LEVEL 133'-6 13/16"
134'-3 13/16"
SECOND LEVEL
130'-6 13/32"

FIRST LEVEL
120'-11 13/16"

LOWER LEVEL
110'-7 1/16"

LOWER LEVEL 2
100'-0"

C2 LONGITUDINAL BUILDING SECTION


A-301 SEAL | DATE 04/01/21
1/16" = 1'-0"

SHEET ISSUE
1 Construction Documents 04/01/21
9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2 9.8 8.9 7.9 6.9 5.9 5.5 5.1 4.1 3.1 2.1 1.2

C2 C2
A-301 A-301
D3 A3
A-322 A-322

D6 A6
A-322 A-322
T/O PARAPET T/O PARAPET
142'-8" 142'-8"

SECOND LEVEL SECOND LEVEL


130'-6 13/32" 130'-6 13/32"

FIRST LEVEL FIRST LEVEL


120'-11 13/16" 120'-11 13/16"

LOWER LEVEL LOWER LEVEL


110'-7 1/16" 110'-7 1/16"

LOWER LEVEL 2 LOWER LEVEL 2


100'-0" 100'-0"

A2 MID TRANSVERSE BUILDING SECTION A5 NORTH TRANSVERSE BUILDING SECTION COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A-301 A-301 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
1/16" = 1'-0" 1/16" = 1'-0"

PROJECT NO. 19010.000


SHEET TITLE

BUILDING SECTIONS
4/1/2021 11:33:14 AM

SHEET NUMBER

A-301
KEYNOTE LEGEND

RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
S SIM 1 1/2" STANDING SEAM METAL E1 5500 Wabash Avenue
C1 ROOF, 5/8" COVER BOARD, 5"
A-350
A-321 Terre Haute, Indiana 47803
RIGID INSULATION, 1 1/2" 812-877-1511
METAL DECK
E5 5/8" GYPSUM CEILING
A-321

C7
A-351
3" / 1
2 " SIM
A3
A-350

2 1/2" X 6" CURTAIN


WALL SYSTEM Architect
RATIO
+/- 7'-9 1/4"

101 South Pennsylvania Street


Indianapolis, Indiana 46204
317-633-4040
SIM

+/- 4'-0 7/8"


A1 Structural Engineer
A-350
+/- 14'-4 1/4"
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
SIM Indianapolis, Indiana 46240
A1 317-872-8400
A-350

46'-7" REUSE EXISTING METAL STUD


FRAMING OR PROVIDE MORE
Mechanical / Electrical Engineer
AS REQUIRED FOR
SHEATHING AND INSULATION. R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

E1 SOUTH MONITOR SECTION E5 SOUTH MONITOR LONGITUDINAL SECTION


A-321 A-321
1/2" = 1'-0" 1/2" = 1'-0"

STANDING SEAM
E6 METAL GABLE
A-351 E6
A-350 FLASHING
5.9 5.5 5.1
METAL COPING
PREFINISHED STANDING SEAM METAL ROOF PANELS
ACM PANELS ON
PARAPET BEYOND SELF-ADHERING WATERPROOF MEMBRANE
UNDERLAYMENT OVER 5/8" COVER BOARD AND 5"
RIGID INSULATION
NOMINAL 4X6 STRUCTURAL WOOD DECKING
STAINED TO MATCH EXPOSED DECKING ON
FLOORS BELOW

2X WOOD NAILER PARALLEL TO TRUSS

2"
/1
7" 7"

1'-
/1

0"
2"
4'-11 5/16"

SNOW GUARDS

TREATED WOOD
BLOCKING AS REQ.

SPRAY FOAM INSULATION SEAL | DATE 04/01/21


D6
A-350 3" RIGID INSULATION WITH
5/8" EXT. GYPSUM ON 3
5/8" COLD FORM METAL
FRAMING.
5"X5" METAL GUTTER

STEEL ANGLE, SEE STRUCTURAL

HEAVY GUAGE METAL FLASHING


SPRINKLERS TO RUN THROUGH 4"X4" METAL DOWNSPOUT
PRE-DRILLED HOLES IN BEAMS
2 1/2" X 6" CURTAINWALL SYSTEM,
1" INSULATED GLAZING SHEET ISSUE
1 Construction Documents 04/01/21

EXTEND STEEL COLUMNS, SEE


EXTEND DRYWALL STEEL TUBE TRUSS, STRUCTURAL
TO NEW SEE STRUCTURAL
UNDERSIDE OF
6'-9 1/4"

ROOF EXTEND INTERIOR FRAMING UP


TO NEW SILL

CURTAINWALL SUPPORT TUBE,


SEE STRUCTURAL

NEW ROOF MEMBRANE. 5/8" COVER 6" 6 1/8"


BOARD ON TOP OF 3" RIGID INSULATION
WITH 5/8" EXT. GYPSUM ON 3 5/8" COLD 2
FORM METAL FRAMING. A-350
2'-10 1/8"

NEW DUCT CHASE REPLACEMENT


IN EXISTING LOCATION

LEVEL 5 FINISH
LEVEL 5 FINISH

NEW ROOF MEMBRANE ON


NEW INSULATION
2'-5 1/2"

EXISTING WOOD DECKING

6'-4" 6'-4"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

ROOF MONITOR
SECTIONS
4/1/2021 11:33:20 AM

A3 CENTRAL MONITOR SECTION SHEET NUMBER


A-321
3/4" = 1'-0"

A-321
KEYNOTE LEGEND

RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
D3 317-634-4672
C1 A-322
A-350

D6
A-322

1 1/2" STANDING SEAM METAL


ROOF, 5/8" COVER BOARD, 5"
7"

+/- 7'-0 3/8"


/1 RIGID INSULATION, 1 1/2"
2" METAL DECK, 3 5/8" COLD
FORMED METAL FRAMING, 5/8"
GYPSUM BOARD.

2 1/2" X 6" CURTAIN COLD FORMED METAL

+/- 2'-3 1/2"


WALL SYSTEM FRAMED STRUCTURE FROM
T/O EXISTING STEEL UP,
PAINTED GYPSUM DELEGATED DESIGN. +/- 13'-10 1/2"
BOARD BEYOND

A3
A-350

REUSE EXISTING METAL STUD


FRAMING OR PROVIDE MORE
AS REQUURED FOR
SHEATHING AND INSULATION A4
A1 +/- 8'-1 1/2" A-350
A-350

D3 MID MONITOR SECTION D6 MID MONITOR LONGITUDINAL SECTION


A-322 A-322
1/2" = 1'-0" 1/2" = 1'-0"

SEAL | DATE 04/01/21

A3
A-322 SHEET ISSUE
C1 1 Construction Documents 04/01/21
A-350

A6
A-322
1 1/2" STANDING SEAM METAL
ROOF, 5/8" COVER BOARD, 5"
A4
+/- 7'-0 19/32"

RIGID INSULATION, 1 1/2"


A-350
7" METAL DECK, 3 5/8" COLD
/1 FORMED METAL FRAMING, 5/8"
2"
GYPSUM BOARD.

2 1/2" X 6" CURTAIN COLD FORMED METAL


WALL SYSTEM FRAMED STRUCTURE FROM
5'-0"

+/- 1'-1 5/8"

T/O EXISTING STEEL UP,


DELEGATED DESIGN.
PAINTED GYPSUM
BOARD BEYOND A1
A-350
REUSE EXISTING METAL STUD
FRAMING OR PROVIDE MORE
AS REQUURED FOR
A3 SHEATHING AND INSULATION
3/4"

A-350

1'-0"
+/- 10'-1 1/4" +/- 20'-0"
5'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

ROOF MONITOR
SECTIONS
A3 NORTH MONITOR SECTION A6 NORTH MONITOR LONGITUDINAL SECTION
4/1/2021 11:33:25 AM

A-322 A-322
1/2" = 1'-0" 1/2" = 1'-0"

SHEET NUMBER

A-322
KEYNOTE LEGEND

051200.A00 STRUCTURAL STEEL FRAMING


054000.A01
054000.A02
COLD-FORMED METAL FRAMING - 3 5/8"
COLD-FORMED METAL FRAMING - 6"
RHIT MOENCH
D
054000.A03
061053.B01
061053.F05
COLD-FORMED METAL FRAMING - 8"
WOOD BLOCKING
MISCELLANEOUS ROUGH CARPENTRY,
RENOVATION
074113.16.A00 061516.A01
PLYWOOD, 3/4"
WOOD ROOF DECKING (SEE STRUCTURAL) 5500 Wabash Avenue
074113.16.B01
074113.16.E01
061600.B05
072100.C7
WALL SHEATHING, GLASS-MAT GYPSUM, 1/2"
Terre Haute, Indiana
074113.16.A00 STANDING-SEAM METAL ROOF PANELS
074113.16.D01 074113.16.B01 STANDING-SEAM METAL ROOF PANELS,
UNDERLAYMENT
47803
074113.16.D02 RIDGE CAP, TURN DOWN
AT EDGE OF ROOF 074113.16.D01 2” RIGID INSULATION Owner
061053.F05 074113.16.D02 3” RIGID INSULATION
EXTEND MEMBRANE ROOFING UP Rose-Hulman Institute of Technology
061516.A01 WALL TO ROOF PEAK 074113.16.E01 COVER BOARD
C2 5500 Wabash Avenue
074213.23.B01 METAL-FACED COMPOSITE METAL WALL PANEL
A-301 Terre Haute, Indiana 47803
074213.23.C02 METAL COMPOSITE METAL WALL PANEL,
WRAP ROOF UNDERLAYMENT
SUBGIRT 812-877-1511
MEMBRANE 8" MIN DOWN VERTICAL 5.5
RIDGE CAP 075323.A01 EPDM MODIFIED BITUMINOUS MEMBRANE
FACE AND LAP OVER MEMBRANE 074113.16.A00
ROOFING SYSTEM

8"
FLASHING ZEE CLOSURE, 074113.16.B01
SET IN SEALANT 075323.D01 3” RIGID INSULATION
076200.D06 074113.16.E01 075323.E01 COVER BOARD
REMOVE & REINSTALL EXISTING 076200.C01 HANGING GUTTER
ASPHALT SHINGLES AS REQUIRED 074113.16.D01
TO EXTEND MEMBRANE ROOFING 076200.D01 BASE FLASHING
074113.16.D02
3'-0" UNDER SHINGLE ROOFING. 076200.D02 COUNTERFLASHING
061053.F05 076200.D06 FASCIA, METAL
077253.A00 SNOW GUARDS
075323.D01 075323.A01
079200.C01 BACKER ROD AND SEALANT Architect
075323.E01 075323.E01 084413.A00 GLAZED ALUMINUM CURTAIN WALLS RATIO
054000.A02 075323.D01 092216.A01 1 5/8" METAL STUD FRAMING, NON-STRUCTURAL
101 South Pennsylvania Street
092216.B01 2 1/2" METAL STUD FRAMING, NON-STRUCTURAL Indianapolis, Indiana 46204
061053.F05
051200.A00 092216.C01 3 5/8" METAL STUD FRAMING, NON-STRUCTURAL 317-633-4040
N6 5.9
092900.B04 GYPSUM BOARD, 5/8"

Structural Engineer
061053.F05 Fink Roberts & Petrie, Inc.
061516.A01 9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

051200.A00
Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
E6 MONITOR RIDGE 732 N Capitol Avenue
A-350 Indianapolis, Indiana 46204
1 1/2" = 1'-0" 317-634-4672
D D

5.9
074113.16.A00 077253.A00

074113.16.B01

2X ROOF FRAMING FOR NEW CRICKET 074113.16.E01


074113.16.D01
EXISTING ROOF STRUCTURE, REMOVE 074113.16.D02
EXISTING ASPHALT SHINGLES DOWN TO EXISTING MASONRY
ROOF DECK AS REQUIRED TO INSTALL NEW PILASTER
CRICKET
092900.B04
075323.A01
061053.F05 STARTER FLASHING W/DRIP
054000.A01 061053.F05
075323.D01
076200.C01
075323.E01
092900.B04 061516.A01
EXTEND UNDERLAYMENT
092216.B01 051200.A00
MEMBRANE OVER
079200.C01 MEMBRANE FLASHING
084413.A00 061053.B01
076200.D06
WRAP MEMBRANE FLASHING SPRAY-FOAM INSULATION
AROUND BLOCKING

D1 SECTION DETAIL - MONITOR ENDS D4 CLERESTORY JAMB D6 MONITOR DETAIL


A-350 A-350 A-350
1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0"

5.9
WRAP ROOF
UNDERLAYMENT 3" CAP @ BASE EXTEND ROOF MEMBRANE
ZEE CLOSURE, SET IN
MEMBRANE 8" MIN BEHIND SEALANT JOINT
SEALANT
DOWN VERTICAL LINEAR BAR GRILLE
FACE AND LAP OVER 074113.16.A00 074113.16.A00 084413.A00
MEMBRANE FLASHING 074113.16.B01 074113.16.B01
ZEE CHANNEL SET 079200.C01 LINEAR BAR GRILLE
074113.16.E01 IN SEALANT 074113.16.E01
061053.B01 076200.D01
074113.16.D01 074113.16.D01
076200.D06 RAKE FLASHING 092900.B04
074113.16.D02 074113.16.D02
075323.A01 092216.C01
061053.F05 061053.F05
SET PANEL EDGE 075323.E01
074113.16.E01
IN CONT. BEAD 075323.D01
072100.C7 OF SEALANT SEAL | DATE 04/01/21
LINE PLYWOOD
074113.16.E01 TROUGH WITH
SHEET METAL
054000.A03 061053.B01
WRAP MEMBRANE T/O PARAPET
FLASHING AROUND 074213.23.B01 142'-8"
INSULATION AND
TERMINATE AT MULLION 074213.23.C02
061053.F05 4"X12" VENTS @16"
075323.A01 061053.F05 O.C. BETWEEN
CLEAT & DRIP EDGE 075323.E01 STUDS, VERIFY WITH
061053.F05 054000.A01 MECHANICAL
079200.C01 079200.C01 074113.16.A00
054000.A02 @16" O.C. MIN ALIGN WITH FACE OF
092900.B04 074113.16.B01 075323.D01
084413.A00 EXISTING COLUMN
054000.A02 074113.16.E01 WRAP BELOW
SHEET ISSUE
077253.A00 061600.B05 8 1/2" VIF 1 Construction Documents 04/01/21
074113.16.D01
C1 MONITOR HEAD DETAIL 074113.16.D02
2 SectionDtl- Clerestory SIll
A-350 A-350
1 1/2" = 1'-0" 061053.F05 054000.A02 1 1/2" = 1'-0"

EXTEND METAL
MEMBRANE ROOF SYSTEM
ROOFING
TO EXTEND UP BEHIND
UNDERLAYMENT
ACM WALL PANELS AND
OVER MEMBRANE
TERMINATE AT STANDING 092900.B04
ROOFING SYSTEM
084413.A00 SEAM METAL ROOF. SET
ATTACHMENT GIRTS IN EXISTING STONE 9.8
076200.D06
CONTINUOUS BEAD OF COPING
061053.B01
3" CAP @ SILL SEALANT AND FASTEN
092216.A01 T/O PARAPET
INTO PLYWOOD, SEAL
054000.A02 HEADS OF ALL FASTENERS 142'-8"
EXISTING STEEL TO 075323.A01 REPLACE EXISTING SEALANT
REMAIN, REMOVE ALL 092900.B04 JOINT AND SET NEW
079200.C01 EXISTING FINISH COUNTERFLASHING IN JOINT
061053.F05
MATERIALS, ROOFING
MATERIALS AND 076200.D02
075323.D01
5 1/2"

ASSOCIATED SUPPORT
SYSTEMS DOWN TO ROOF DRAIN
075323.A01
075323.A01 ROOF DECK PRIOR TO
092900.B04 075323.E01 075323.E01
075323.E01 INSTALLING NEW WORK TERMINATION BAR EXISTING MASONRY
054000.A01 CRICKET 075323.D01
075323.D01 092216.C01 PARAPET
T/O PARAPET T/O PARAPET T/O PARAPET
142'-8" 142'-8" 142'-8"
075323.E01 EXISTING STEEL TO INFILL EXISTING
REMAIN, REMOVE ALL 061053.F05 SCUPPER WITH
EXISTING FINISH MASONRY - 3-5/8"
092900.B04 MATERIALS, ROOFING 054000.A01 LIMESTONE ON
075323.A01 MATERIALS AND 075323.A01 SALVAGED BRICK
092216.C01 ASSOCIATED SUPPORT WITH METAL COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
SYSTEMS DOWN TO COPING. AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
075323.A01 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
ROOF DECK PRIOR TO COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
INSTALLING NEW WORK
PROJECT NO. 19010.000
EXISTING ROOF DECK
ALIGN FINISH FACE SHEET TITLE
TO SOFFIT BELOW EXISTING WOOD DECK
EXTERIOR DETAILS

EXISTING WOOD DECK


4/1/2021 11:33:33 AM

SHEET NUMBER
A1 SECTION DETAIL - MONITOR SILL A3 SECTION DETAIL - MONITOR BASE A4 SECTION DETAIL - MONITOR SIDES A6 TYP SECTION DETAIL @ EXIST PARAPET
A-350
1 1/2" = 1'-0"
A-350
1 1/2" = 1'-0"
A-350
1 1/2" = 1'-0"
A-350
1 1/2" = 1'-0"
A-350
G

METAL COPING

075323.A01
074213.23.B01
RHIT MOENCH
074213.23.C02
RENOVATION
054000.A02

5.9
061053.F05 5500 Wabash Avenue
075323.D01
074113.16.E01 Terre Haute, Indiana
3 LAYERS TYPE X
47803

2'-6"
BOTH SIDES

074113.16.A00 Owner
092900.B04
074113.16.B01 Rose-Hulman Institute of Technology

4"
092216.C01 5500 Wabash Avenue
074113.16.E01
Terre Haute, Indiana 47803
074113.16.D01 812-877-1511
054000.A03
074113.16.D02

8"
3 LAYERS
084413.A00 BOTH SIDES 061053.F05
076200.C04

G
074213.23.B01
Architect

075323.A01
RATIO
101 South Pennsylvania Street
061053.F05 Indianapolis, Indiana 46204
092900.B04
075323.D01 2" 3 1/2" 3 1/2" 2" CONTINUE 317-633-4040
3 LAYERS
075323.E01 OF GYP 092216.C01
ACROSS TO
Structural Engineer
EXTERIOR
SHEATHING Fink Roberts & Petrie, Inc.
ABOVE 9449 Priority Way W Dr #200
COLUMN
Indianapolis, Indiana 46240
317-872-8400
3 LAYERS 5/8" GYP BD TYPE X
INSET AT COLUMN. EXTEND 2"
ABOVE ROOF DECK Mechanical / Electrical Engineer
R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
TERMINATE RATED
PARTITION AT BACK SIDE OF Indianapolis, Indiana 46204
EXTERIOR SHEATHING 317-634-4672

E4 PLAN DETAIL E6 SECTION DETAIL -RATED CLERESTORY DIVIDER


A-351 A-351
1 1/2" = 1'-0" 1 1/2" = 1'-0"

074113.16.A00

ZEE CHANNEL SET 074113.16.B01


IN SEALANT 074113.16.E01

RAKE FLASHING 074113.16.D01


074113.16.D02

SET PANEL EDGE


IN CONT. BEAD
OF SEALANT

061053.B01
074113.16.E01
072100.C7
074113.16.E01
WRAP MEMBRANE FLASHING
AROUND INSULATION AND
TERMINATE AT MULLION

CLEAT & DRIP EDGE 092900.B04


079200.C01 079200.C01
084413.A00 061053.B01
S5

U C7 ROOF EDGE DETAIL


A-351
1 1/2" = 1'-0"
SEAL | DATE 04/01/21

EXISTING LADDER SAFETY POLE


ROOF DECK
1" OFF FACE OF EXISTING TRUSS
PREFABRICATED ROOF HATCH
WITH 20" HIGH CURBS WITH
INTEGRAL ROOF FLASHING A5
RECEIVERS A-351 SHEET ISSUE
1 Construction Documents 04/01/21

DOOR FRAME 5/8" EXT. GYP


SHEATHING
5/8" GYP BD
PROVIDE MTL.
VAPOR BARRIER COUNTERFLASHING

1'-4"
SAFETY GATE TO ALLOW FOR
FUTURE RE-ROOFING
3-5/8" METAL
STUDS MEMBRANE
ROOFING
SYSTEM

ACCESS
PANEL

MTL. ROOF DECK


DECK CLOSURE CHANNEL (TYP,)
MTL. ROOF FRAMING

5/8" G.W.B. 3/4" DIAMETER RUNGS WELDED TO


1/2" X 2-1/2"
REMOVE & REPLACE SIDE RAILS 2'-0" O.C. VERTICAL
STEEL BAR RAIL
DRYWALL AS REQUIRED
TO INSTALL NEW
BLOCKING BETWEEN 3"x6"x3/8"x3" LONG CLIP ANGLE 1" DIA STEEL RUNG
STUDS FOR CLIP 2 1/2" MTL. FRAMING SUPPORTS WELDED TO RAILS 6" WELDED TO SIDE
SUPPORTS @ 4' 0" O. C. RAIL @ 12" O.C.

1" DIA STEEL RUNG SUSPENDED CEMENT STEEL CLIP SUPPORTS


WELDED TO SIDE PLASTER CEILING 60" OC MAX
RAIL @ 12" O.C. SYS. ANCHOR TO WALL
3/8"x2 1/2" STEEL SIDE RAILS
STEEL CLIP SUPPORTS 18" APART
EXISTING
60" OC MAX COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
FLOOR/CEILING AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
ANCHOR TO WALL 6" CMU SEE FLOOR PLAN DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
FOR WALL TYPE
T/O PARAPET
142'-8" PROJECT NO. 19010.000
ANGLE ATTACHMENT SHEET TITLE
TO FLOOR
1/2" X 2-1/2"
STEEL BAR RAIL
FLOOR LINE
EXTERIOR DETAILS
ANGLE ATTACHMENT
6"

TO FLOOR
4/1/2021 11:33:40 AM

PATCH VAPOR BARRIER &


INSULATION AT ABANDONED
OPENINGS AND WHERE DAMAGED

SHEET NUMBER
A2 MECH ROOM LADDER A3 ATTIC MECH WALL SECTION A5 ROOF HATCH DETAIL A7 CRAPO ROOF HATCH
A-351
1/2" = 1'-0"
A-351
1 1/2" = 1'-0"
A-351
1 1/2" = 1'-0"
A-351
1/2" = 1'-0" A-351
KEYNOTE LEGEND

00-A1 CENTER WALL ON COLUMN GRID LINE


N8 N7 N6 N5 RHIT MOENCH
RENOVATION

1/32"
1'-0"
Toilet Room Accessories (Internal)
5500 Wabash Avenue
1'-0" Type Mark Description Manufacturer Model Assembly Code
1'-6"
1'-6"

MICROWAVE 12C MOP AND BOBRICK B-223x24 C1090.40


Terre Haute, Indiana
47803
5'-11 7/8"

MICROWAVE BROOM
HOLDER
1'-0"
1'-0" Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue

11'-3 3/16"
2'-0"

6"
2'-0" Terre Haute, Indiana 47803
812-877-1511

1'-6" CLEAR
16'-1 27/32"
D7 A-502 D6

60" CLEAR MIN.


1'-6"
2'-0" D5
E7 D2 2'-0"
A-501
6'-9 1/16"

D1

16'-3 5/8"
E2 A-502 G6
1'-5 1/4" Architect
A5 A5 A5
00-A1 00-A1 A5 E1 RATIO
A-532 A-532 A-532
00-A1 00-A1

11'-1 5/8"
A-532
C C C C 1'-6" 101 South Pennsylvania Street
PAPER SHREDDER
PAPER SHREDDER BY OWNER
Indianapolis, Indiana 46204
BY OWNER 317-633-4040
2'-0"
3'-3 5/16"

1'-0" Structural Engineer


FRIG. FRIG. Fink Roberts & Petrie, Inc.
2'-0"

1'-6"
1'-0" 9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400
8'-0 1/8"

Mechanical / Electrical Engineer


N8 N7 N6 N5 R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

E1 ENLARGED PLAN - FACULTY COLLISION LL1 E4 ENLARGED PLAN - FACULTY COLLISION LEVEL 1 E7 ENLARGED PLAN - FIRST LEVEL CONF. ROOM STORAGE
A-401 A-401 A-401
3/8" = 1'-0" 3/8" = 1'-0" 1/4" = 1'-0"

N1

12C
3'-0"

1'-3"
B4

A-502

6"

N1

7 ENPLN - FIRST LEVEL - JANITOR CLOSET SEAL | DATE 04/01/21


A-401
1/4" = 1'-0"

6"
1'-6"

1'-6" CLEAR
E3 A-501 E1
SHEET ISSUE

11'-10 1/2"
E2
1 Construction Documents 04/01/21

6'-10 1/2"
1'-6"

1'-6"
7'-6"

B1 FACULTY COLLISION - LOWER LEVEL 1 B4 FACULTY COLLISION - FIRST LEVEL B7 ENPLARGED PLAN - LOWER LEVEL 1 STORAGE
A-401 A-401 A-401
1/4" = 1'-0"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

ENLARGED PLANS
4/1/2021 11:34:00 AM

SHEET NUMBER

A-401
N9 N8 N7 N6

KEYNOTE LEGEND
8.9 7.9 6.9 5.9
RHIT MOENCH
101419.A00
105113.A00
DIMENSIONAL LETTER SIGNAGE
METAL LOCKER
123623.13.D01 COUNTER TOP FLIP-UP COUNTERBALANCE
RENOVATION
D D
SYSTEM
5500 Wabash Avenue
S3C.C
1'-6" 9'-10" 1'-6"

S3C.C
Terre Haute, Indiana
2'-3"

S3C
REACH-IN FRIG. REACH-IN FRIG.
A7 2'-0"
123623.13.D01 CT-02
KITCHEN
CG-01 Toilet Room Accessories (Internal) 47803

2'-3"
A-530 C5 A-402 B1 A1 START OF QUARRY TILE CG-01 EL125
S3C S3C PT-05 Type Mark Description Manufacturer Model Assembly Code
A2 KITCHEN Owner

1'-0"
EL125 CG-01 W FRP-01
A-602 S3A.C
N9 N8 N7 N6

1'-0"
C4
B QTB-01 Rose-Hulman Institute of Technology
B3 A-402 A5 F QT-01 12C MOP AND BOBRICK B-223x24 C1090.40
1'-0" 4'-1 3/16" BROOM 5500 Wabash Avenue
CG-01 HOLDER Terre Haute, Indiana 47803
3-COMPARTMENT B5 105113.A00 812-877-1511
DISHWASHER SINK S3A.C
C5 CAFE
EL127

DW

DW
FREEZER FRIG. W PT-07
A-403 C1 B RB-01
1'-0" 1'-6" F QT-01
ICE
CT-02
S3A.C CG-01
A-402 A4

B4 MOP ROOM STORAGE


S3A.C
EL128
Architect

7'-11"
EL126
12C STORAGE W FRP-01
W FRP-01
MOP SINK EL126 B QTB-01
B QTB-01 RATIO
F QT-01
2'-6"
10 SF
F QT-01 101 South Pennsylvania Street
Indianapolis, Indiana 46204

1'-6"
1'-0" 1'-8"
1'-0"
317-633-4040

2'-0"
2'-8"
E S3A.C E CG-01

2'-0"
S3C.D.A CT-02 CT-02

9 31/32"
1'-2"
S3C PT-05

3"
2'-10 1/2" 1'-1 3/4" 1'-1 3/4" PT-05 Structural Engineer

1 1/2"
ALIGN PT-05

2"
B7 PT-06 RB-02
C4 A-532
RB-03 Fink Roberts & Petrie, Inc.
B5
A-532
A-530 9449 Priority Way W Dr #200
ALIGN TILE TRANSITION WITH VERTICAL Indianapolis, Indiana 46240
FACE OF RECESSED TOEKICK SHOWN 317-872-8400
WITH DASHED LINE 3" FROM VERTICAL
FACE OF CASEWORK

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
8.9 7.9 6.9 5.9
732 N Capitol Avenue
Indianapolis, Indiana 46204
F2 ENLARGED PLAN - CAFE F5 ENLARGED FINISH PLAN - CAFE 317-634-4672
A-402
A-402 1/4" = 1'-0"
1/4" = 1'-0"

10'-10"
CENTER TILE
BETWEEN
WING WALLS, TYP

8'-0" 4'-6"
PT-05 PT-05
1 1/2"

PL-04 F1
1'-10 1/4"

TILE A7 PL-04 RECESSED FIRE


MITRED 10" 10" 10" 5'-10 3/4" A7 A-531 EXTINGUISHER
CT-02 CT-02 STARTS AT A-531 PL-03 D3 F6 QZ-01
CORNER A-531
COUNTER
4'-0"

QZ-01 VD-02 QZ-01 PL-02 A-531 A-531


PL-02 123623.13.D01
F3 C1 PL-04
PL-03 A-531 A-530 PL-03 PL-04
8"

8"

8"
MERCHANDISER

1'-10 1/4"

4'-0"
3'-6"

ALIGN
2'-10"

2'-10"

2'-10"

2'-10"
PL-02
2'-6"

2'-6"
PL-02 PL-02 PL-02

RB-03
5'-5" 9'-10 7/16" 2'-8" 2'-7 1/2"1'-1 1/4" RB-02 2'-0" 3'-3" 3'-3" 1'-3" PL-02 5'-1" 1'-10" 3'-6" 1'-6" 3'-0"
A1 F1
A-531 A-531 SEAL | DATE 04/01/21
5 1/4" F5 D5 PROVIDE A1 D1 PROVIDE CAMLOCKS 5 1/4" 1 1/2"
A-531 A-531 A-531 A-531
CAMLOCKS ON ON ALL DRAWERS
ALL DRAWERS AND CABINETS
AND CABINETS

C1 INTERIOR ELEVATION C4 INTERIOR ELEVATION C5 INTERIOR ELEVATION


A-402 A-402 A-402
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

SHEET ISSUE
1 Construction Documents 04/01/21
A4 A3
PT-05 A-540 101419.A00 FULL HEIGHT FRP FULL HEIGHT FRP FULL HEIGHT FRP
A-531
PT-06 BEYOND
2'-0 3/4"

PT-05
TILE STARTS AT PL-01
COUNTERTOP
1'-0"

CT-02
3'-4 1/4"

1'-0" EQ EQ 1'-0"
E1
8'-6"

8'-6"
8'-3"

A-530
PL-03
QZ-01 D6
SSM-01 A-531
4'-8"

6"
2'-10"

A8 A8
2'-6"

PL-02 PL-02 A-650


D.W. ICE A-650

2'-6" 2'-0" 2'-6" 2'-6" PROVIDE CAMLOCKS ON


1'-3" A8 SHELVING BY OTHERS
ALL DRAWERS AND A-650
3/4" FILLER PANEL 1" CLEARANCE CABINETS
1" CLEARANCE E6
A-530

B1 INTERIOR ELEVATION B3 INTERIOR ELEVATION B4 INTERIOR ELEVATION B5 INTERIOR ELEVATION


A-402 A-402
A-402 A-402 1/4" = 1'-0"
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

FULL HEIGHT FRP FULL HEIGHT FRP


A3
A-531
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
1'-0"1'-0"1'-0" AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
PL-01 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
1'-0"

1'-0" 1'-0" TILE STARTS


CT-02 AT COUNTER 105113.A00 PROJECT NO. 19010.000
EQ EQ
C1 PL-04 SHEET TITLE
6'-0 1/8"

A-530

CAFE
4'-8"

A8 A8
2'-10"

2'-10"

A-650 PL-02 A-650

4'-0"
4/1/2021 11:34:15 AM

TABLES BY OTHERS A8
A-650

A1 INTERIOR ELEVATION A3 INTERIOR ELEVATION A4 INTERIOR ELEVATION A5 INTERIOR ELEVATION SHEET NUMBER
A-402

A-402
A-402 A-402 1/4" = 1'-0" A-402
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
RHIT MOENCH
RENOVATION
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


R.E. Dimond & Associates, Inc.
732 N Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672

E1 AXON-CAFE
A-403

EXISTING DRYWALL REVEALS

WALLCOVERING CONTINUES BEHIND COLUMN 34'-10 1/2" ALTERNATE A-4. SEAMING DIAGRAM IF ALTERNATE APPROVED 38'-1 7/8"

WALLCOVERING STOPPING
POINT BEHIND COLUMN

8'-0 1/2"
1'-1 1/2"
8'-3"

WC-01

10'-10"
WC-01 WC-01
101419.A00 D1
A-540

10"
1'-10 1/2"

2'-1 1/2"
EXISTING DRYWALL REVEALS
PT-07
PT-07 PT-07 PT-05 PT-07 PT-05 PT-07

10'-4 3/4"

10'-4 3/4"
D3 8"
F6 PL-04 PT-05
A-531
1'-3 3/4"

8'-3 1/4"

A-531
123623.13.D01 QZ-01 QZ-01

7'-2"
PL-04
1'-0"

SEAL | DATE 04/01/21


3'-6"

PL-02 PL-02
2'-6"

PL-03 PL-03
PL-02

RB-03 1'-6" 1'-6"


3'-0" 1'-6" 5'-4" 5'-1" 2'-8 3/8"
FULL TILE STARTS AT FLOOR
1 1/2" 5 1/4" A4
A-530

C5 INTERIOR ELEVATION
C1 INTERIOR ELEVATION A-403
1/4" = 1'-0"
A-403 SHEET ISSUE
1/4" = 1'-0"
1 Construction Documents 04/01/21
CLEAR HEAD HEIGHT BELOW STAIRS

UNDERSIDE OF EXISTING STAIRS

SELF REVEAL
6'-9 3/4"

QZ-01
SEATING PLATFORM
A6
A-530 SEATING PLATFORM A6 QZ-01
A-530 COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
1'-6"

DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
1'-6"

WD-01 WD-01
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
2"

2"

6'-0"
1/2" 4'-0" 1/2" 4'-0" 1/2" 4'-0"
PROJECT NO. 19010.000
SHEET TITLE
WIDTH TO MATCH WIDTH
BETWEEN INTERIOR
FACES OF STRINGERS
14'-6" +/- CAFE
A1 INTERIOR ELEVATION A3 INTERIOR ELEVATION
A-403 A-403
4/1/2021 11:35:08 AM

1/4" = 1'-0" 1/4" = 1'-0"

SHEET NUMBER

A-403
KEYNOTE LEGEND
RHIT MOENCH
051200.A00 STRUCTURAL STEEL FRAMING
092900.B03
092900.B04
GYPSUM BOARD, 1/2"
GYPSUM BOARD, 5/8"
RENOVATION
097553.A01 VEGETATIVE WALL SYSTEM
5500 Wabash Avenue
Terre Haute, Indiana
47803
Owner
Rose-Hulman Institute of Technology
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

9.8 8.9 7.9

Architect
EXISTING DRYWALL REVEALS
RATIO
101 South Pennsylvania Street
SEATING PLATFORM BELOW B4
Indianapolis, Indiana 46204

2" TRIM
A-404 317-633-4040
WD-01
2" TRIM 29'-6" 2" TRIM
Structural Engineer
A-404
Fink Roberts & Petrie, Inc.

6'-3"
ALIGN
9449 Priority Way W Dr #200
E4 A1 1'-0 13/32"
A-403 Indianapolis, Indiana 46240
317-872-8400
8 1/4" PLANTING DPETH

A5
B6
1'-3" CABINET DEPTH

A-301
A-404

14'-4 7/8" Mechanical / Electrical Engineer


A3
R.E. Dimond & Associates, Inc.
A-403
732 N Capitol Avenue
CABINET BELOW
1'-0 3/8" Indianapolis, Indiana 46204

16'-11"
097553.A01 317-634-4672
2" 2"
GREENERY

1'-3"
29'-10" WD-01 WD-01
G G

1'-3 1/2"
WD-01
9.8 8.9 7.9 BASE CABINET

097553.A01

E1 ENLARGED PLAN - LIVING WALL E4 INTERIOR ELEVATION


A-404 A-404
1/4" = 1'-0" 1/4" = 1'-0"

3/4" 7 1/4" 1/4" REVEAL

VERSA 2" RETRUN EDGE TRIM WD-01


VERSA 7" MULTI-PURPOSE TRIM WD-01
GSKY TRIM LIGHT BRACE (3 PER 6") WD-01
GSKY TRIM HEAVY BRACE (2 PER 6") WD-01
2"

VERSA DRIPLINE
4 3/4"

VERSA BACKING SCREWS


SEAL | DATE 04/01/21
VERSA BACKING
VERSA TRAY WITH SELECTED
5 3/4"

PLANTS BY GSKY
051200.A00

092900.B04

092900.B03

VERSA BACKING
SHEET ISSUE
REMOVABLE VERSA 4" WD-01
BOTTOM EDGE TRIM 1 Construction Documents 04/01/21
4 3/4" TYP

DRAINLINE - GSKY 1" PEX PIPE VERSA BACKING


VERSA BACKING SCREWS EXISTING BRICK WALL EXISTING BRICK WALL 092900.B03
REMOVEABLE FRONT COVER WD-01
SUPPLY LINE - GSKY
4 3/4" MANDATORY GAP

3/4" PEX PIPE 092900.B04

1'-0" REFER TO PLUMBING FOR GSKY TRIM LIGHT


PUMP/EQUIPMENT REQUIREMENTS BRACE (3 PER 6')

1/4" REVEAL
1'-3 1/2"

7 1/4"
VERSA 7" MULTIP-
PURPOSE EDGE TRIM
BASE CABINET BY GSKY OR MILLWORKER.
VERSA 2" RETURN

3/4"
EDGE TRIM
VERSA TRAY WITH
HONEYWELL WATER DEFENSE SELECTED PLANTS BY
1/2"

GSKY
BOTTOM TRIM BELOW
MANDATORY GAP 3/4" 2"
10 1/2" ADJUSTABLE FEET, PART OF CABINET. MANDATORY GAP 3/4"

3/4" 3/4"

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


B1 AXON - LIVING WALL B4 INTERIOR DETAIL B6 INTERIOR DETAIL AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A-404 A-404 A-404 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
1 1/2" = 1'-0" 1 1/2" = 1'-0"
PROJECT NO. 19010.000
SHEET TITLE

LIVING WALL
4/1/2021 11:35:54 AM

SHEET NUMBER

A-404
KEYNOTE LEGEND

RHIT MOENCH
7.9 6.9 5.9
D6
A-421 RENOVATION
D2
A-421 T/O PARAPET
142'-8"
5500 Wabash Avenue
7.9 6.9 5.9 5.5 5.1 Terre Haute, Indiana

10"
D6
F7
A-540
A-421
47803
WALL MOUNTED HANDRAIL Owner

6'-8" MIN.
Rose-Hulman Institute of Technology
F6
A-423 5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511
S6A.A
N SECOND LEVEL 2'-4 3/8" 3'-0" A1 A-502 A5
133'-6 13/16"
1" / 12"
+/- 8"

4'-6 1/2"
SECOND LEVEL D5
130'-6 13/32" A-421

13'-5 3/4"
D2
A-421
G116

1'-8"
(2X) LAYERS 3/4" PLYWOOD ON 1 1/2" METAL DECK
Architect
COLD FORMED METAL FRAMING AS REQUIRED TO SUPPORT RAMP E E RATIO
F2 NORTH RAMP - N SECTION 101 South Pennsylvania Street
A-421 S2C Indianapolis, Indiana 46204

3'-9 1/4"
1/4" = 1'-0" 1'-0" 1'-0"
F2 317-633-4040
A-421 5'-0" 28'-6 1/8"

5 TREADS @ 11" = 4'-7"

1'-0"
Structural Engineer

2 3/4"
D2
Fink Roberts & Petrie, Inc.
A-421 A1 9449 Priority Way W Dr #200
5.9 6.9 7.9 A-423 D6 Indianapolis, Indiana 46240
S3A A-423
below 317-872-8400
2 3/4"

8'-4 1/4"
GLASS GUARDRAIL C6
A1
A-423 WRAP HANDRAIL WRAP HANDRAIL INFILL WITH LIKE WALL

11"
EXPOSED EXISTING TRUSS AROUND AROUND CONSTRUCTION, Mechanical / Electrical Engineer
C5 A-422
BEYOND, PREPPED AND S3A GUARDRAIL GUARDRAIL
5'-0" 2 3/4" 13'-6" ALIGN TO EXISTING R.E. Dimond & Associates, Inc.

+/- 1'-1 3/4"


PAINTED HIGH below FINISH FACE
732 N Capitol Avenue

2 3/4"
D5 PERFORMANCE PAINT TO CLEAR C3
A-621 MATCH PT-01 Indianapolis, Indiana 46204
317-634-4672
D5
METAL HANDRAIL 5'-0" 8'-0" A-621

3'-10 3/4"
W01 ATTACHED TO E201
STOREFRONT
SYSTEM STOREFRONT E2
W02 MULLIONS A-421 +/- 11 1/2" 15'-7 3/8" +/- 1'-0 1/4" 15'-7 3/8"

+/- 8"
1" / 12" F F
D3 A-423
SECOND LEVEL W01 W02
130'-6 13/32" 1'-0" 1'-0"
NEW PIPE
RAILING, FINISH
F6 (2X) LAYERS 3/4" PLYWOOD TO MATCH ADJ.
E2 NORTH RAMP - S SECTION A-422
ON 1 1/2" METAL DECK E5 NORTH RAMP PLAN RAILING
A-421 A-421
1/4" = 1'-0" COLD FORMED METAL FRAMING AS 1/4" = 1'-0"
REQUIRED TO SUPPORT RAMP

F2 E D5
A-421 A-421
5.9
E2 F2
F A-421 A-421 E

E6

6 EQ. RISERS @ +/- 3'-0 3/8"


A-621 METAL D6
GLASS A-423
MECHANICAL G116
EXPOSED GUARDRAIL

EQ
RAILING
EXISTING TRUSS,

3'-6"
DOOR AS
PREPPED AND C6
SELF SUPPORTING SCHEDULED
PAINTED

EQ
INFILL OPENINGS FROM A-423
METAL PLATFORM
STOREFRONT REMOVED WINDOWS AND ALTERNATING N SECOND LEVEL N SECOND LEVEL
133'-6 13/16" 133'-6 13/16"

+/- 3'-0 3/8"


SYSTEM TREAD DEVICE
A6
D6 A-423
A-621
SECOND LEVEL SECOND LEVEL SECOND LEVEL
130'-6 13/32" 130'-6 13/32" 130'-6 13/32"

(2X) LAYERS 3/4" PLYWOOD


(2X) LAYERS 3/4" PLYWOOD
ON 1 1/2" METAL DECK
ON 1 1/2" METAL DECK
COLD FORMED METAL FRAMING AS
COLD FORMED METAL FRAMING AS REQUIRED TO SUPPORT FLOOR
REQUIRED TO SUPPORT RAMP EXTENSION
SEAL | DATE 04/01/21
D2 NORTH RAMP - W SECTION D5 MECH RM ENTRY SECTION D6 STAIR AND FLOOR EXTENSION SECTION
A-421 A-421 A-421
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

U
GLASS GUARDRAIL S8 B2
S7 S6
SYSTEM A-421

A2 A3
A-421 A-423 METAL HANDRAIL S3C
T SHEET ISSUE
1 Construction Documents 04/01/21
+/- 1'-7 3/8"

5'-0"
5'-0" 26'-1 1/2" +/- 3'-1 5/8" VIF CUT BACK
S SECOND LEVEL A2
134'-3 13/16" GUARDRAIL AND
E1 1" / 12" A-421
A5 E3 STRINGER AT NEW
5'-0"

A-422 A-423 A-422 RAMP LANDING


+/- 2'-2"

SECOND LEVEL
130'-6 13/32"

GLASS GUARDRAIL GLASS GUARDRAIL


(2X) LAYERS 3/4" PLYWOOD
ON 1 1/2" METAL DECK

+/- 11'-8 1/4" V.I.F.


EXISTING STAIR
A5 AND GUARDRAIL
B2 SOUTH RAMP SECTION - N/S TO REMAIN.
A-421 A3 A-422 A7
1/4" = 1'-0"

A3
19'-4 3/4"

A-423
A3
B2 A-423
S3C
A-421
S6 S7 S8 SIM. O.H.

GLASS GUARDRAIL
U
EXISTING STAIR METAL HANDRAIL, ATTACHED TO A5 NEW RAMP
AND RAILING TO STUD WALL AND GLASS GUARDRAIL A-423 BETWEEN
REMAIN AS REQUIRED ALONG RAMP EXISTING BEAMS
BEYOND

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
EXISTING BEAM DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
WRAP HANDRAIL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
AROUND
S SECOND LEVEL GUARDRAIL
134'-3 13/16"
PROJECT NO. 19010.000
E3 E5
A-422 SHEET TITLE
A-422
1" / 12" STAIR AND RAMP
SECOND LEVEL
130'-6 13/32" 4'-7 7/8" PLANS AND
SECTIONS
4/1/2021 11:36:02 AM

WOOD PLANKING ON TOP OF 1/2"


(2X) LAYERS 3/4" PLYWOOD METAL STUD PLYWOOD BACKING, FINISHED TO
ON 1 1/2" METAL DECK FRAMING CEILING MATCH EXISTING EXPOSED WOOD S3A
SUPPORT FLOOR DECKING
SHEET NUMBER

A2
A-421
SOUTH RAMP SECTION - E/W
1/4" = 1'-0"
A5
A-421
SOUTH RAMP PLAN
1/4" = 1'-0"
A-421
GLAZING SCHEDULE KEYNOTE LEGEND
GL-01 CLEAR INSULATING GLASS, LOW-E COATED - EXTERIOR
APPLICATIONS 02-A1 EXISTING WALL CONSTRUCTION
GL-02 CERAMIC COATED SPANDREL GLASS - EXTERIOR
APPLICATIONS
02-A3
02-B1
EXISTING FLOOR CONSTRUCTION
EXISTING STRUCTURAL FRAMING
RHIT MOENCH
GL-03 INSULATING, CERAMIC COATED VISION GLASS -
EXTERIOR APPLICATIONS
GL-04 CLEAR INSULATING GLASS, LOW-E COATED, LAMINATED
09-A1
09-A3
WALL BASE, REFER TO FINISH PLAN FOR TYPE
FLOOR FINISH, REFER TO FINISH PLAN FOR
TYPE
RENOVATION
- EXTERIOR APPLICATIONS, FIRE RATED
GL-11 CLEAR TEMPERED GLASS - INTERIOR APPLICATIONS,
WINDOWS AND DOORS
033000.A02
051200.A00
CAST-IN-PLACE CONCRETE SLAB
STRUCTURAL STEEL FRAMING 5500 Wabash Avenue
GL-12 DECORATIVE GLASS, FILM OVERLAY - INTERIOR
APPLICATIONS
051200.B01
051200.C01
STRUCTURAL STEEL FRAMING, COLUMN
STRUCTURAL STEEL FRAMING, BEAM Terre Haute, Indiana
053100.A01 STEEL DECKING
GL-13 CLEAR, LAMINATED - INTERIOR APPLICATIONS, FIRE
RATED 055113.A02 METAL PAN STAIR WITH CONCRETE FILLED
TREADS, PAINTED
47803
GL-15 CLEAR TEMPERED LAMINATED GLASS - INTERIOR
APPLICATIONS, RAILINGS 055213.A00 PIPE AND TUBE RAILING Owner
057313.C01 SHOE MOUNTED GLASS RAIL
Rose-Hulman Institute of Technology
061053.B01 WOOD BLOCKING
5500 Wabash Avenue
061053.F03 MISCELLANEOUS ROUGH CARPENTRY,
PLYWOOD, 1/2" Terre Haute, Indiana 47803
061053.F05 MISCELLANEOUS ROUGH CARPENTRY,
812-877-1511
PLYWOOD, 3/4"
079200.A01 SEALANT
092216.B02 2 1/2" METAL STUD FRAMING, NON-STRUCTURAL,
WITH SOUND ATTENUATION
092216.C01 3 5/8" METAL STUD FRAMING, NON-STRUCTURAL
092216.C02 3 5/8" METAL STUD FRAMING, NON-STRUCTURAL,
WITH SOUND ATTENUATION
092216.F02 7/8" METAL FURRING
092900.B04 GYPSUM BOARD, 5/8"

GYPSUM FLOOR Architect


LEVELING COMPOUND, 061053.B01
RATIO

3/4"
MAINTAIN SMOOTH

3/4"
053100.A01 101 South Pennsylvania Street
TRANSITION FROM
061053.F05 Indianapolis, Indiana 46204
PLYWOOD TO EXISTING
FLOOR TO RECEIVE 1" / 12" MIN. 317-633-4040
FLOOR FINISH
SECOND LEVEL
130'-6 13/32"

1 1/2"
Structural Engineer
S8
Fink Roberts & Petrie, Inc.
+/- 5 1/16" 9449 Priority Way W Dr #200
V.I.F. 02-A3
Indianapolis, Indiana 46240
02-A1 317-872-8400
092216.C01 092216.C02 02-A3

092900.B04 092900.B04 S SECOND LEVEL Mechanical / Electrical Engineer


134'-3 13/16"
09-A1 09-A1 F6 NORTH RAMP DETAIL R.E. Dimond & Associates, Inc.
079200.A01 079200.A01 092216.C02 A-422
1 1/2" = 1'-0" 732 N Capitol Avenue
09-A3 09-A3 Indianapolis, Indiana 46204
092216.F02
317-634-4672
02-A1 092900.B04
VARIES VARIES

051200.C01 092216.C02
051200.C01

+/- 1 7/16"
092216.C01 09-A1 033000.A02
092216.C01 061053.F05
051200.A00 079200.A01 1'-6"
061053.F05 053100.A01 02-B1

1" MIN.
SEE STRUCTURAL 09-A3
053100.A01 1" / 12" MIN.
FOR BEARING
DETAIL 061053.F05 051200.A00
SEE STRUCTURAL
BEYOND TO SUPPORT BEYOND TO 053100.A01 FOR FRAMING
WOOD CEILING SUPPORT WOOD
DETAILS
CEILING 02-A3
061053.F03 V.I.F.
061053.F03
02-A1 WOOD CEILING WOOD
REPAIR FINISH AWP-02 CEILING
AS REQUIRED AWP-02 E6 CRAPO RAMP DETAIL
A-422
1 1/2" = 1'-0"

E1 RAMP BEARING WALL DETAIL E3 RAMP WALL DETAIL E5 RAMP BEAM DETAIL
A-422 A-422 A-422
1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0"
N10
N10

FIRST LEVEL
120'-11 13/16" C

S7FA
4" 1'-0" 1'-0"
092216.F02 1'-0 1/4"

10'-1" V.I.F.
092216.B02 EXISTING ACT
EQ EQ +/- 11'-4 1/2"
CEILING
092900.B04
+/- 16'-6 1/8" V.I.F. EXISTING STRUCTURE, REMOVED
051200.B01 F6

+/- 7'-0"
TO HEIGHT OF EXISTING DOOR D5
055213.A00
4 1/4"

EQ EQ EQ EQ A-423 OPENING ACROSS WIDTH OF A-422


D5 CORRIDOR. CLAD WITH
+/- 9 1/8"

A-423 REPAIR WALL


DRYWALL AND PAINT IF ABLE TO CONSISTENT
DRYWALL MAINTAIN 7'-0" HEAD HEIGHT. WITH ADJACENT

+/- 11"
ON METAL FINISH AFTER
FURRING 1" / 12" LOWER LEVEL REMOVAL OF
3'-4"

1'-0" 1'-0"
BEYOND WING WALL S7FA S3C
110'-7 1/16"
S7FA
092900.B04
ALIGN THIS SIDE +/- 6'-2 1/4" VIF
092216.C02 WITH EXISTING
CONCRETE RAMP SEAL | DATE 04/01/21
092216.F02 FINISH FACE BEYOND 057313.C01
02-A1
02-A3 E6
A-422

COLUMN WRAP DETAIL N10


D1 A126 SOUTH D3 BRIDGE INFILL RAILING ELEVATION D5 CRAPO CONNECTOR RAMP SECTION D6 CRAPO CONNECTOR RAMP PLAN
A-422 A-422 A-422 A-422
1 1/2" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

092216.F02 28'-6 1/8" +/- 1'-2 11/16"


051200.B01 SHEET ISSUE
092216.C02 EQ EQ EQ EQ EQ EQ EQ 1 Construction Documents 04/01/21
ALIGN THIS SIDE
092900.B04
WITH EXISTING 8'-9 3/4"
A1
FINISH FACE BEYOND 8'-0" A-423
1'-2 5/8" EQ EQ 1'-2 5/8"
EQ EQ
A1

3'-6"
+/- 9 1/8"

A1 A-423
A-423

3'-6"
3'-6"

055213.A00 055213.A00
3'-6"

057313.C01 055213.A00
057313.C01
092900.B04 057313.C01 055113.A02
092216.C02
092216.F02

COLUMN WRAP DETAIL NORTH RAMP - NORTH RAMP - NORTH RAMP -


C1 A126 NORTH C3 S RAILING ELEVATION C5 W RAILING ELEVATION C6 N RAILING ELEVATION
A-422 A-422 A-422 A-422
1 1/2" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

092216.C02

092216.F02
051200.B01
S6
ALIGN WITH
EXISTING FINISH 10"
FACE BEYOND

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE


A3 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
055213.A00 A-423 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
A3 SIM.
+/- 9 1/8"

A5 057313.C01 COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
BEYOND +/- 19'-4 13/16" V.I.F. 057313.C01 A-423 057313.C01 A-423 O.H.
+/- 29'-7 3/16" V.I.F. +/- 11'-8 1/4" V.I.F.
PROJECT NO. 19010.000
4 1/4"

EQ EQ EQ EQ EQ SHEET TITLE
EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ
STAIR AND RAMP
3'-6"

3'-6"

3'-6"
092900.B04
1'-2 7/8"
092216.B02
PLANS, SECTIONS,
092216.F02 055213.A00
ALIGN WITH
02-A3
BEYOND 02-A3 02-A3 EXISTING
AND DETAILS
4/1/2021 11:36:15 AM

GUARDRAIL BEYOND
EXISTING FINISH TO REMAIN, PAINTED
FACE BEYOND
COLUMN WRAP DETAIL SOUTH RAMP - SOUTH RAMP - SOUTH RAMP -
SHEET NUMBER
A1 A138 A3 W RAILING ELEVATION A5 N RAILING ELEVATION A7 E RAILING ELEVATION
A-422
1 1/2" = 1'-0"
A-422
1/4" = 1'-0"
A-422
1/4" = 1'-0"
A-422
1/4" = 1'-0"
A-422
KEYNOTE LEGEND

02-A3 EXISTING FLOOR CONSTRUCTION


02-B1
09-A3
EXISTING STRUCTURAL FRAMING
FLOOR FINISH, REFER TO FINISH PLAN FOR
RHIT MOENCH
TYPE
09-K2
051200.A00
PAINTED, MATCH SURROUNDING ELEMENTS
STRUCTURAL STEEL FRAMING
RENOVATION
1 1/2" CLEAR
1 1/2" O.D. METAL
HANDRAIL
051200.C01
053100.A01
STRUCTURAL STEEL FRAMING, BEAM
STEEL DECKING 5500 Wabash Avenue
STEEL RAILING
054000.A01
055213.A00
COLD-FORMED METAL FRAMING - 3 5/8"
PIPE AND TUBE RAILING Terre Haute, Indiana
BRACKET @ 5'-0" 055213.A01 STEEL PIPE AND TUBE RAILING
O.C. MAX. 057313.A00 GLAZED DECORATIVE METAL RAILINGS 47803
057313.C01 SHOE MOUNTED GLASS RAIL
2' - 10" ABOVE
061053.F03 MISCELLANEOUS ROUGH CARPENTRY, Owner
TREAD NOSING OR PLYWOOD, 1/2"
LANDING Rose-Hulman Institute of Technology
079200.C01 BACKER ROD AND SEALANT
FACE OF WALL, REFER TO 5500 Wabash Avenue
084113.C02 ALUMINUM-FRAMED ENTRANCES AND
FLOOR PLANS FOR WALL STOREFRONTS - INTERIOR, 4 1/2" FRAME DEPTH Terre Haute, Indiana 47803
TYPE, BACKUP SUPPORT AS 812-877-1511
REQUIRED 092216.B01 2 1/2" METAL STUD FRAMING, NON-STRUCTURAL
092216.C02 3 5/8" METAL STUD FRAMING, NON-STRUCTURAL,
WITH SOUND ATTENUATION
F6 WALL BRACKET DETAIL 092900.B04 GYPSUM BOARD, 5/8"
A-423
1 1/2" = 1'-0" 092900.F04 GYPSUM BOARD TRIM ACCESSORIES, J CASING
BEAD

Architect
RATIO
LOW PROFILE METAL
CAP RAIL, FINISH TO 101 South Pennsylvania Street
MATCH GLAZING SHOE Indianapolis, Indiana 46204
317-633-4040
055213.A00
Structural Engineer
GLASS
SUPPORTED
Fink Roberts & Petrie, Inc.
METAL RAILING 9449 Priority Way W Dr #200
BRACKET Indianapolis, Indiana 46240
317-872-8400

3'-6" @ LANDING / NOSING


Mechanical / Electrical Engineer

3'-0" @ LANDING / NOSING


R.E. Dimond & Associates, Inc.
057313.C01
732 N Capitol Avenue
Indianapolis, Indiana 46204
F 317-634-4672

5.1
3 3/4" MAX PIPE
+/- 2 3/4" 5" 2" LOW PROFILE METAL
SPACING
CAP RAIL, FINISH TO
MATCH GLAZING SHOE

2 3/4"
PRE-FINISHED METAL
1 1/2" SHOE CLADDING
1 1/2" 2"
084113.C02

4 1/4"
057313.C01 LOW PROFILE
ALUMINUM BASE SHOE

055213.A01
09-K2
STEEL CHANNEL
EXISTING STRINGER
RAILING TO
REMAIN

3'-6"

3'-6"
COPE S.S. SILL
AND PLYWOOD
D6 STAIR GUARD RAILING DETAIL
A-423
AROUND PIPES 1 1/2" = 1'-0"

MATCH EXISTING
2 3/4"
PRE-FINISHED METAL
SHOE CLADDING
LOW PROFILE

4 1/4"
ALUMINUM BASE SHOE GLAZING BEYOND

RAILING SHOE
SECOND LEVEL 02-A3 SECOND LEVEL
130'-6 13/32" 130'-6 13/32" (2)X 3/4" PLYWOOD ON
1 1/2" METAL DECK
051200.A00

DELEGATED COLD
FORMED METAL STUD
FRAMING

D3 RAILING INFILL DETAIL D5 BRIDGE INFILL RAILING DETAIL SEAL | DATE 04/01/21
A-423 A-423
1 1/2" = 1'-0" 1 1/2" = 1'-0" CONCRETE FILL

FORMED STEEL SHEET


TREAD AND RISER

REFER TO FINISH PLAN FOR


TREAD AND RISER FINISH
LOW PROFILE METAL
TREAD WIDTH
CAP RAIL, FINISH TO
LOW PROFILE METAL (REFER TO PLAN)
MATCH GLAZING SHOE LOW PROFILE METAL
CAP RAIL, FINISH TO CAP RAIL, FINISH TO
MATCH GLAZING SHOE MATCH GLAZING SHOE
055213.A00
SHEET ISSUE
1 Construction Documents 04/01/21
GLASS
SUPPORTED
METAL RAILING
BRACKET C6 STAIR RISER/TREAD DETAIL AT LANDING
A-423
057313.A00 1 1/2" = 1'-0"
057313.A00
055213.A00

GLAZING BEYOND
3'-6"

GLASS
SUPPORTED
3'-0"

METAL RAILING
3'-6"

3'-6"

RAILING SHOE
BRACKET

REFER TO FINISH PLAN FOR


TREAD AND RISER FINISH
055213.A00

PRE-FINISHED METAL 2 3/4" GLASS


3'-0"

09-A3 SUPPORTED
SHOE CLADDING
2 3/4" METAL RAILING
LOW PROFILE 061053.F03 PRE-FINISHED METAL BRACKET 2 3/4"
4 1/4"

ALUMINUM BASE SHOE CLADDING


3/8"

SHOE 053100.A01 PRE-FINISHED METAL STRINGER


VARIES 09-A3 09-A3
LOW PROFILE SHOE CLADDING
4 1/4"

4 1/4"

ALUMINUM BASE
LOW PROFILE 02-A3
3/8"

SHOE
3/8"

079200.C01 S SECOND LEVEL ALUMINUM BASE SHOE S SECOND LEVEL


REFER TO SECTION

079200.C01 134'-3 13/16" 134'-3 13/16"


(RISER HEIGHT)

092900.F04 054000.A01
079200.C01 CONCRETE FILL
092900.F04 COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
092900.B04 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
092900.B04 02-A3 092900.F04 FORMED STEEL SHEET DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL

EXISTING WOOD TREAD AND RISER COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
051200.A00 ADHERED TIGHT 3" WOOD DECKING 1" TYPICAL
TO EXISTING 092900.B04 BEAM BEYOND
SEE STRUCTURAL PROJECT NO. 19010.000
WOOD BEAM 02-B1
092216.B01 051200.C01 SHEET TITLE
TREAD WIDTH 3"x3"x 1/4" STEEL CLIP
BEYOND
SECOND LEVEL 092216.C02 6" (REFER TO PLAN) ANGLE. ANCHORED TO
CONCRETE AND WELDED
STAIR AND RAMP
130'-6 13/32" TO INSIDE FACE OF BOTH
STRINGERS DETAILS
4/1/2021 11:36:20 AM

A1 NORTH RAMP RAILING DETAIL A3 SOUTH RAMP RAILING DETAIL A5 SOUTH RAMP RAILING DETAIL A6 STAIR RISER/TREAD DETAIL AT FLOOR
A-423 A-423 A-423 A-423
1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0"
SHEET NUMBER

A-423
KEYNOTE LEGEND

101100.A00 VISUAL DISPLAY UNIT

PROJECTION SCREEN PROJECTION SCREEN


105500.16 PRIVATE DELIVERY POSTAL SPECIALTIES RHIT MOENCH
A6
SEEN AT ANGLE SEEN AT ANGLE
RENOVATION
A6 3'-0"
2'-4 1/2" A-531 8'-0" 7'-11 15/16" 8'-0"
8'-0" 8'-0" 8'-0"
A-531 6'-5" 5500 Wabash Avenue
Terre Haute, Indiana
VD-01
47803
4'-0"
VD-01 VD-01 101100.A00
VD-01 VD-01 VD-01

4'-0"
Owner
Rose-Hulman Institute of Technology

5'-0"
101100.A00 101100.A00
5500 Wabash Avenue
3'-6"

3'-0"
Terre Haute, Indiana 47803
812-877-1511

G1 INTERIOR ELEVATION G3 INTERIOR ELEVATION G5 INTERIOR ELEVATION


A-501 A-501 A-501
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

Structural Engineer
8'-0" 8'-0" 8'-0"
Fink Roberts & Petrie, Inc.
F3 EXPOSED CONCRETE BEAM 9449 Priority Way W Dr #200
A6 A-530 COLUMN Indianapolis, Indiana 46240
A-531 317-872-8400
A3 F6 F3
PL-02 A3 A-531 A3 A-530
A-531 PL-02 A-530
PL-02 A-531

1'-11"
1'-8"
PL-01 PL-01 Mechanical / Electrical Engineer
1'-6" EQ EQ EQ EQ

1'-6" EQ EQ EQ EQ

4'-0"
9" CLEAR

1'-6" EQ EQ EQ EQ
VD-01 VD-01 VD-01 R.E. Dimond & Associates, Inc.
PL-04

2'-0"
732 N Capitol Avenue

1'-9"
SSM-01 SSM-01
6'-6 1/4"

6'-6 1/4"
Indianapolis, Indiana 46204

6'-6 1/4"
317-634-4672
101100.A00

2'-10"

2'-10"
3'-6"
PL-01 PL-01

FILL WIDTH 3'-0" 3'-0" E6


A-530
E6 PAPER SHREDDER,
A-530 OWNER PROVIDED

E1 INTERIOR ELEVATION E2 INTERIOR ELEVATION E3 INTERIOR ELEVATION E5 INTERIOR ELEVATION E7 INTERIOR ELEVATION
A-501 A-501 A-501 A-501
1/4" = 1'-0" 1/4" = 1'-0" A-501 1/4" = 1'-0" 1/4" = 1'-0"
1/4" = 1'-0"

PROVIDE BLOCKING AND WALL


MOUNTED PRAGUE SINGLE ROBE
EQ EQ EXPOSED CONCRETE BEAM
F5 F1 HOOK 353655 IN BRUSHED
A-530 A-530
COLUMN BEHIND STAINLESS STEEL FINISH, TYP.
COLUMN
EQ EQ EQ EQ EQ 3'-2 1/4" DOOR SWING
MICROWAVE F3
1'-0"

2'-6" CLEAR A-530 EQ EQ EQ EQ EQ EQ EQ EQ


SHELF

10" 10" 10"


2'-6"
1'-11"
1'-6" CLEAR

PL-01 PL-04 PL-04


4'-0"

VD-01
PL-04
E6 C6
1'-9"

COUNTER CONTINUES
1'-8"

SSM-01 D6

72" AFF
A-530 A-530
A-531
SSM-01 IN FRONT OF COLUMN

48" AFF
1'-0"

8'-0" 1'-0" EQ EQ EQ EQ EQ 1'-0" EQ EQ


2'-10"

2'-10"
3'-0"

PL-01

1'-2" 3'-0" 3'-0" 3'-0" 1'-1"


CART STORAGE
MOVEABLE TABLES
E4 BY OWNER
A-530

D1 INTERIOR ELEVATION D2 INTERIOR ELEVATION D4 INTERIOR ELEVATION D5 INTERIOR ELEVATION


A-501 A-501 A-501 A-501
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

SEAL | DATE 04/01/21

2" CLEAR MIN. A5


A-531 1'-2 7/16"
105500.16
COORD. WITH MANUF.

D6
A-531 SHEET ISSUE
CORRIDOR BEYOND
SSM-01 CORRIDOR BEYOND 1 Construction Documents 04/01/21

6" 6"

RECOMMENDED HEIGHT PER


X

MANUFACTURER

B3 INTERIOR ELEVATION B2 INTERIOR ELEVATION


A-501 A-501
1/4" = 1'-0" 1/4" = 1'-0"

EXPOSED CONCRETE BEAM


COLUMN
A5 DOOR SWING
8'-0"
A-531
105500.16 PROVIDE BLOCKING AND WALL
MOUNTED PRAGUE SINGLE ROBE
HOOK 353655 IN BRUSHED
1'-6 1/32"

4'-0"
STAINLESS STEEL FINISH COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
VD-01 AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL

72" AFF
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000

3'-0"
1 3/16" SHEET TITLE

INTERIOR
RECOMMENDED HEIGHT PER
MANUFACTURER ELEVATIONS
4/1/2021 11:36:33 AM

A1 INTERIOR ELEVATION A7 INTERIOR ELEVATION


A-501 A-501
1/4" = 1'-0" 1/4" = 1'-0"
SHEET NUMBER

A-501
KEYNOTE LEGEND
REFER TO AV FOR
MONITOR SIZE
RHIT MOENCH
101100.A00 VISUAL DISPLAY UNIT
8'-9" ALIGN 2'-2 1/8" 8'-0" 101100.A00 8'-0" 8'-0" 2'-2 1/8" A3
A-531
RENOVATION
PL-02 TYP
101100.A00 5500 Wabash Avenue

1'-6" EQ EQ EQ EQ
Terre Haute, Indiana

4'-0"
E6 VD-01 VD-01 VD-01
A-530
QZ-01
47803

4"

6'-6"
5'-3"
2'-10"
PL-04 Owner

3'-3"
Rose-Hulman Institute of Technology
3'-6" 3'-6" 3'-6"
5500 Wabash Avenue
Terre Haute, Indiana 47803
812-877-1511

G1 INTERIOR ELEVATION G3 INTERIOR ELEVATION G4 INTERIOR ELEVATION G6 INTERIOR ELEVATION


A-502 A-502 A-502 A-502
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040

DOOR SWING
5" 8'-0" EQ EQ 8'-0" 5 1/2" 8'-0" 8'-0" REFER TO AV FOR Structural Engineer
A3 MONITOR SIZE PROVIDE BLOCKING AND WALL
A3 PL-02 TYP
1'-6" CLEAR
MOUNTED PRAGUE SINGLE Fink Roberts & Petrie, Inc.
A-531 PL-02 TYP A-531
EQ EQ
ROBE HOOK 353655 IN BRUSHED 9449 Priority Way W Dr #200
EQ EQ STAINLESS STEEL FINISH Indianapolis, Indiana 46240
1'-6" EQ EQ EQ EQ

1'-6" EQ EQ EQ EQ

EQ

EQ
317-872-8400

4'-0"

4'-0"

4'-0"
VD-01 VD-01 VD-01 VD-01 1'-6" VD-01

6'-6 1/4"

EQ

EQ
6'-6"

Mechanical / Electrical Engineer

72" AFF
R.E. Dimond & Associates, Inc.

5'-0"

5'-0"
101100.A00 101100.A00 8'-0" 732 N Capitol Avenue

3'-0"

3'-0"

3'-0"
REFER TO AV FOR Indianapolis, Indiana 46204
MONITOR SIZE 317-634-4672

E1 INTERIOR ELEVATION E2 INTERIOR ELEVATION E4 INTERIOR ELEVATION E5 INTERIOR ELEVATION


A-502
1/4" = 1'-0"
A-502
1/4" = 1'-0"
A-502
1/4" = 1'-0"
A-502
1/4" = 1'-0" E8 INTERIOR ELEVATION
A-502
1/4" = 1'-0"

PROJECTION SCREEN 2'-6" PROJECTION SCREEN


A6 SEEN AT ANGLE A6 F6
A-531
SEEN AT ANGLE EQ EQ COLUMN BEHIND F5
A-531 F3 A-530
1'-7" 8'-0" 8'-0" 8'-0" 1'-7 1/8" A-530
A-530 COLUMN
8'-0" 8'-0" 8'-0" EQ EQ F3
A-530 2'-6" CLEAR

1'-11"

1'-8"

1'-0"
PL-01 PL-01 9" CLEAR, TYP
4'-0"

1'-11"
4'-0"

VD-01 VD-01 VD-01 VD-01 VD-01 VD-01

4'-0"
PL-01
VD-01

2'-0"
1'-9"
SSM-01 PL-04 PL-04
E6 C6

1'-9"
SSM-01

1'-0"

1'-6" CLEAR
A-530 A-530
8'-0"

2'-10"

2'-10"
3'-3"
3'-0"

PL-01 PL-01

3'-0"

2'-10"
PL-01

3'-0" 3'-0" 60" CLEAR MIN. FILL WIDTH


3'-0" 3'-0" 1'-2"
PAPER SHREDDER,
OWNER PROVIDED
E4
A-530

D1 INTERIOR ELEVATION D3 INTERIOR ELEVATION D5 INTERIOR ELEVATION D6 INTERIOR ELEVATION D7 INTERIOR ELEVATION
A-502 A-502 A-502 A-502 A-502
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

EQ EQ

MECHANICAL SHAFT BEYOND


DOOR SWING COLUMN DOOR SWING
8'-0"
PROVIDE BLOCKING AND PROVIDE BLOCKING AND
3'-0" SEAL | DATE 04/01/21
WALL MOUNTED PRAGUE WALL MOUNTED PRAGUE
SINGLE ROBE HOOK 353655 IN 12C A3 PL-02
1'-6" SINGLE ROBE HOOK A-531 A1
BRUSHED STAINLESS STEEL A1
4'-0"

4'-0"

1'-5 31/32" 353655 IN BRUSHED QZ-01 A-530 QZ-01


VD-01 FINISH VD-01 A-530
STAINLESS STEEL FINISH
6" 6"
72" AFF

72" AFF

QZ-01 A1 A1 QZ-01
5'-0"
A-530 A-530

4'-0"

4'-0"
WD-01 WD-01
3'-0"

3'-0"

1'-8 1/4"

1'-8 1/4"
WD-01 WD-01

FLOOR MOUNTED HVAC UNIT MOP SINK S.S. TRIM V.I.F. REPAIR DRYWALL WHERE 1'-11" S.S. TRIM V.I.F. V.I.F.
TILE WAS REMOVED
REPAIR DRYWALL WHERE
TILE WAS REMOVED SHEET ISSUE
1 Construction Documents 04/01/21

B1 INTERIOR ELEVATION B3 INTERIOR ELEVATION B4 INTERIOR ELEVATION B5 INTERIOR ELEVATION B7 INTERIOR ELEVATION
A-502 A-502 A-502 A-502 A-502
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

A5
A-301
A5
A-301

F2 D5
A-421 A-421

F7
LEVEL 5 FINISH E7 A-540 LEVEL 5 FINISH
A-540

LEVEL 5 FINISH COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

PROJECT NO. 19010.000


SHEET TITLE

INTERIOR
ELEVATIONS
4/1/2021 11:36:48 AM

SHEET NUMBER

INTERIOR ELEVATION INTERIOR ELEVATION


A1
A-502
1/4" = 1'-0"
A5
A-502
1/4" = 1'-0" A-502
REFER TO ENLARGED PLAN 12"
KEYNOTE LEGEND
RHIT MOENCH
LINE OF SOFFIT
RENOVATION

VARIES
5500 Wabash Avenue
CEILING, REF. REFLECTED WOOD BLOCKING, PAINT 1'-0" 6"
CEILING PLAN FOR HEIGHT TO MATCH SOFFIT
MELAMINE INTERIOR

Terre Haute, Indiana

PER ELEVATION
1/2" BACK PANEL ON CLEATS

PER ELEVATION
1/2" BACK PANEL ON CLEATS 1/2" BACK PANEL ON CLEATS PL-01
PER ELEVATION FINISH EXPOSED WOOD BLOCKING AND
FRAMING TO MATCH CABINET DOOR ABOVE 47803
PL-04
CABINET INTERIOR, PLASTIC Owner
LAMINATE ON ALL EXPOSED REF. ENLARGED PLAN
MELAMINE INTERIOR Rose-Hulman Institute of Technology
SURFACES CABINET ABOVE
GENERAL CASEWORK NOTES

PER ELEVATION
5500 Wabash Avenue

EQ
ALL AXPOSED WOOD
Terre Haute, Indiana 47803
812-877-1511
2 1/2"

2 1/2"
ADJUSTABLE SHELVES, ADJUSTABLE SHELVES MICROWAVE BLOCKING TO MATCH

EQ EQ EQ EQ EQ EQ EQ
LINE OF FRAME BEYOND CABINET ABOVE A. PROVIDE FINISHED END PANELS AT ALL EXPOSED CABINET
PLASTIC LAMINATE
ENDS.

EQ
1/4" BACK PANEL B. PROVIDE FILLER PANELS BETWEEN CORNER CABINETS AND
CUTOUT FOR OUTLET, TYP. BETWEEN CABINETS AND WALLS, UNLESS NOTED
REFER TO ELECTRICAL SHELVES - RECESSED IN
OTHERWISE
SIDES. REFER TO

24"
LIGHTING, REFER TO RCP AND LIGHTING, REFER TO RCP AND C. PROVIDE SEALANT BETWEEN BACKSPLASH AND COUNTER
ELECTRICAL DRAWINGS ELECTRICAL DRAWINGS ELEVATION FOR COUNT.
PL-04 AT PERIMETER WALLS.
BASE CABINET AND D. ▐►PROVIDE EASED EDGES AT ALL SOLID SURFACE AND

1'-0"
BASE CABINET AND
BASE PANEL, PLASTIC BASE PANEL, PLASTIC 1'-0" CLEAR COUNTER WHERE QUARTZ SURFACES.◄▌
COUNTER WHERE
LAMINATE VENEER LAMINATE VENEER INDICATED ON ELEVATIONS E. PROVIDE COUNTERTOP SUPPORT BRACKETS AS REQUIRED
INDICATED ON ELEVATIONS
UNLESS NOTED OTHERWISE ON ELEVATIONS. BRACKETS
TO BE SPACED 48" ON CENTER, MINIMUM. Architect
BASE CABINET AND BASE CABINET AND
F. COORDINATE FINAL ELECTRICAL AND DATA OUTLET RATIO
COUNTER WHERE COUNTER WHERE
LOCATIONS IN CASEWORK/MILLWORK WITH ▐►OWNER,
INDICATED ON ELEVATIONS INDICATED ON ELEVATIONS 101 South Pennsylvania Street
ARCHITECT ◄▌PRIOR TO INSTALLATION.
Indianapolis, Indiana 46204
317-633-4040

F1 UPPER CABINET F3 TYP. KITCHEN UPPER CABINET F5 MICROWAVE CABINET F6 CABINET WITH MAIL SLOTS Structural Engineer
A-530 A-530 A-530 A-530
1" = 1'-0" 1" = 1'-0" 1" = 1'-0" 1" = 1'-0"
Fink Roberts & Petrie, Inc.
9449 Priority Way W Dr #200
Indianapolis, Indiana 46240
317-872-8400

Mechanical / Electrical Engineer


TILE BACKSPLASH WHERE R.E. Dimond & Associates, Inc.
OCCURING, REFER TO ELEVATIONS.
732 N Capitol Avenue

PER ELEVATION

PER ELEVATION

PER ELEVATION
Indianapolis, Indiana 46204
PER ELEVATION

ROUTE 1/4" FROM S.S. TOP


SCRIBE TO WALL W/ SILICONE 317-634-4672
ROUTE 1/4" FROM S.S. TOP ROUTE 1/4" FROM S.S. TOP
REFER TO PLUMBING BEAD AT LOC. OF NO SPLASH
SCRIBE TO WALL W/ SILICONE SCRIBE TO WALL W/ SILICONE
DRAWINGS FOR FAUCET AND
REFER TO ENLARGED PLAN BEAD AT LOC. OF NO SPLASH REFER TO ENLARGED PLAN BEAD AT LOC. OF NO SPLASH REFER TO ENLARGED PLAN
24" SINK TYPE. INSTALL FOR ADA COUNTERTOP FINISH PER
COMPLIANCE COUNTER FINISH PER COUNTER FINISH PER ELEVATION
7" min. SOLID SURFACE ELEVATION ELEVATION
COUNTERTOP AND BACK EDGE PULL
SPLASH DOOR PANEL, WOOD
3/4" FIXED APRON PANEL, VENEER FINISH
FINISH PER ELEVATION. 3/4" MDF ADJ. SHELF CLAD IN

EQ
DRAWER

EQ
FACE OF APRON PANEL TO MELAMINE ON STD'S & BRACKETS
DRAWER

EQ
ALIGN WITH FACE OF (RECESSED IN SIDES)
ADJACENT CABINET FRAME. PULL, REFERENCE PLANS, TYPICAL PULL, REFERENCE PLANS, TYPICAL
1/2" BACK PANEL ON CLEATS
PER ELEVATION

PER ELEVATION

PER ELEVATION

PER ELEVATION
EQ
DRAWER
3/4" PANEL, PLASTIC LAMINATE

EQ
VENEER. SHAPE TOP OF MELAMINE INTERIOR
DRAWER
PANEL WITH 1/8" TOLERANCE
27" min.

EQ
AROUND SINK DRAWER

EQ
1/2" BACK PANEL ON CLEATS 1/2" BACK PANEL ON CLEATS
1/2" BACK PANEL ON CLEATS

EQ
GLIDEWALL CLEAT WITH DRAWER DRAWER

EQ
ROLLER CATCH
9" min.

FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR

6" min.
BASE BASE BASE BASE
11" min. SCRIBE TO FLOOR, TYP. SCRIBE TO FLOOR, TYP. SCRIBE TO FLOOR, TYP. SCRIBE TO FLOOR, TYP.

E1 TYP. KITCHEN SINK BASE ADA E3 DRAWER BASE CABINET E4 DRAWER BASE CABINET E6 BASE CABINET
A-530 A-530 A-530 A-530
1" = 1'-0" 1" = 1'-0" 1" = 1'-0" 1" = 1'-0"

ROUTE 1/4" FROM S.S. TOP


PER ELEVATION

PER ELEVATION

PER ELEVATION
SCRIBE TO WALL W/ SILICONE
BEAD AT LOC. OF NO SPLASH
ROUTE 1/4" FROM S.S. TOP
ROUTE 1/4" FROM S.S. TOP
SCRIBE TO WALL W/ SILICONE COUNTERTOP PER
REFER TO ENLARGED PLAN SCRIBE TO WALL W/ SILICONE
25" BEAD AT LOC. OF NO SPLASH REFER TO ENLARGED PLAN ELEVATIONS
BEAD AT LOC. OF NO SPLASH CABINET DOOR
EQ EQ
SOLID SURFACE FINISH ALL EXPOSED WOOD
COUNTERTOP FINISH PER
COUNTERTOP AND BACK BLOCKING AND FRAMING TO MATCH
ELEVATION.
SPLASH SAME FINISH AS CABINET DOOR
BELOW
EASED SUPPORT EDGE PULL
TRASH GROMMET EDGE (BOTH SIDES)
INLCUDE MAGNETIC PUSH LATCH
PULL, REFERENCE PLANS
SEAL | DATE 04/01/21
PER ELEVATION

PER ELEVATION
SLIDING TRASH
PER ELEVATION

SLIDING TRASH BLACK MELAMINE INTERIOR 3/4" DOOR PANEL,


BLACK MELAMINE INTERIOR DRAWER ON
DRAWER ON FINISH PER ELEVATION
DRAWER GLIDES
DRAWER GLIDES
1/2" BACK PANEL ON CLEATS
DRAWER, PLASTIC
DOOR PANEL, PLASTIC TRASH GROMMET
LAMINATE VENEER
LAMINATE VENEER ABOVE SHOWN MELAMINE INTERIOR
DASHED
1/2" BACK PANEL ON CLEATS
1/2" BACK PANEL ON CLEATS

FINISH FLOOR FINISH FLOOR


FINISH FLOOR
(CONTINUE INTO
CABINET INTERIOR)
BASE LINE OF WALL BASE
SHEET ISSUE
SCRIBE TO FLOOR, TYP. SCRIBE TO FLOOR, TYP.
1 Construction Documents 04/01/21

C1 BASE CABINET W/ TRASH C3 BASE CABINET - TRASH DRAWER C4 PLAN DETAIL - TRASH GROMMET C6 BASE CABINET
A-530 A-530 A-530 A-530
1" = 1'-0" 1" = 1'-0" 1 1/2" = 1'-0" 1" = 1'-0"

EXISTING GYP WALL BEYOND

3'-5 1/2"

SHALE EDGE QZ-01 TOP FOR STUDENT SEATING SHALE EDGE

PLAM COUNTER.FINISH EDGES AND


REFER TO ELEV.

EXISTING CONCRETE SLAB ALL EXPOSED FACES IN MATCHING


WD-01
PLAM. REFER TO INTERIOR
WD-01 STAINLESS STEEL DETAILS AND ELEVATIONS FOR
TRIM FINISH DESIGNATION.
1 1/2" 1 1/2"
SCRIBE TO FLOOR
FINISH ALL EXPOSED WOOD
FINISH FLOOR BLOCKING/FRAMING SAME
1"
REFER TO ELEVATION

FINISH AS CABINET/DRAWERS BASE OF


2"

BELOW.
1/2"

MERCHANDISER
3/4"

ALIGN QZ-01

1 1/2"
EXISTING METAL SHALE EDGE
EXISTING MILLWORK ALIGN
FRAME DECK. REFER TO WALL TILE PER COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE
STRUCTURAL ELEVATION AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
PL-02 DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
6"

3/4"
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
WD-01 PL-04
PL-03
1'-3"

PROJECT NO. 19010.000


STAINLESS STEEL TRIM
1'-6"

COUNTERTOP 2" SHEET TITLE


SCRIBE TO FLOOR STAINLESS STEEL TRIM
FINISH FLOOR
3/4" RB-03
FINISH FLOOR
SURROUND ABOVE
MILLWORK DETAILS
2"
2"

EXISTING DECK. REFER TO STRUCTURAL 2"


SCRIBE TO FLOOR SCRIBE TO FLOOR
4/1/2021 11:36:51 AM

SHEET NUMBER
A1 INTERIOR DETAIL A3 INTERIOR DETAIL A4 INTERIOR DETAIL A6 INTERIOR DETAIL A7 PLAN DETAIL - COUNTER EDGE
A-530
1" = 1'-0"
A-530
6" = 1'-0"
A-530
1 1/2" = 1'-0"
A-530
1" = 1'-0"
A-530
3" = 1'-0"
A-530
KEYNOTE LEGEND

061053.F05 MISCELLANEOUS ROUGH CARPENTRY,


RHIT MOENCH
RENOVATION
PLYWOOD, 3/4"
092900.B04 GYPSUM BOARD, 5/8"
105500.16 PRIVATE DELIVERY POSTAL SPECIALTIES

5500 Wabash Avenue


Terre Haute, Indiana

1 1/2"
1'-2" 1'-6"
1 1/2"
47803
PL-04 PL-03
PLAM PRIVACY PANEL

REFER TO ELEV.
Owner

10"
PL-03

REFER TO ELEV.
CONCEALED SUIPPORT BRACKET Rose-Hulman Institute of Technology
PL-03 TILE BACKSPLASH 1'-0" 1'-10" GENERAL CASEWORK NOTES
MORTAR BED 5500 Wabash Avenue
Terre Haute, Indiana 47803
POWER/DATA FOR 812-877-1511
5" SOUP

2"
PL-03 REFER TO ENLARGED PLAN CONVENIENCE, COORD. W/ A. PROVIDE FINISHED END PANELS AT ALL EXPOSED CABINET

10"
LINE OF SURROUNDING QZ-01 KETTLES ELECTRICAL ENDS.
COUNTER FINISH PER QZ-01
PANEL BEYOND 2" 1'-0" 2" MITRED CORNER, B. PROVIDE FILLER PANELS BETWEEN CORNER CABINETS AND
ELEVATION 2'-8"
PL-04 EDGE PULL FINISH PER ELEVATION EASED EDGE. EDGE PULL BETWEEN CABINETS AND WALLS, UNLESS NOTED
PL-04 COUNTER
PLAM EDGE PULL
DOOR PANEL, PLAM OTHERWISE
ROUTE 2" DIAMETER 3/4" DOOR PANEL, FINISH
1" FINISH PER ELEVATION C. PROVIDE SEALANT BETWEEN BACKSPLASH AND COUNTER
FINISHED PLAM 5" 2'-0" 1" IN RIBBING TO FEED PER ELEVATION
CUTOUT FOR OUTLET. AT PERIMETER WALLS.
PANEL 3/4" MDF ADJ. SHELF CLAD IN CABLES
D. ▐►PROVIDE EASED EDGES AT ALL SOLID SURFACE AND

EQ
MELAMINE ON STD'S & BRACKETS REFER TO ELEC. FINISHED PLAM PANEL DRAWER 3/4" MDF ADJ. SHELF CLAD IN

EQ
QUARTZ SURFACES.◄▌

EQ
(RECESSED IN SIDES) MELAMINE ON STD'S & BRACKETS
E. PROVIDE COUNTERTOP SUPPORT BRACKETS AS REQUIRED

1'-6"
MICROWAVE 2'-0" (RECESSED IN SIDES)
UNLESS NOTED OTHERWISE ON ELEVATIONS. BRACKETS
REFER TO ELEV.

1/2" BACK PANEL ON CLEATS