FDAS - 5-Storey

The document contains a diagram and details of a proposed ground floor fire alarm system for a four-story residential house renovation. The diagram shows the layout of the ground floor with room dimensions and locations of fire detection devices including smoke detectors and pull stations. It also lists component details like the fire detection and alarm control panel, wiring paths between devices, and device identifiers. The fire alarm system is proposed to help ensure fire safety for the renovated residential building.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views4 pages

FDAS - 5-Storey

The document contains a diagram and details of a proposed ground floor fire alarm system for a four-story residential house renovation. The diagram shows the layout of the ground floor with room dimensions and locations of fire detection devices including smoke detectors and pull stations. It also lists component details like the fire detection and alarm control panel, wiring paths between devices, and device identifiers. The fire alarm system is proposed to help ensure fire safety for the renovated residential building.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

FIRE ALARM SYSTEM

A B C

12.64

3.18 2.91 0.72 5.02 0.34

0.74

2.48
T&B

DOOR
SD SD

ACCORDION
ROOM AREA 2
FDAS

6.97
1

DOWN

P
21.13

19.00
19

0.75
18
17
16
T&B
15
14
13
12 SD P
11

6.38
10
9
8
7
ROOM AREA 1
6

0.43
5
4
3

UP
SD
2.50

3
SERVICE GATE
ACCORDION DOOR
2.04 2

0.51 1.94 0.51 5.45 0.46 2.67

11.54

FIRE DETECTION AND ALAM SYSTEM

M GROUND FLOOR PLAN


1 SCALE: 1:100MTS

PCBJR CONSTRUCTIONS SERVICES PROPOSED FOUR STOREY RESIDENTIAL HOUSE RENOVATION


ENGINEERS - CONTRACTOR - DESIGNERS GROUND FLOOR FIRE ALARM SYSTEM
Email Add; pcbjrcons74@[Link] MR & MRS : JOSEPH TAN
jr02_2005@[Link]
Blk 403 Lot-5 P4 Hydros St., Heritage Homes Office No: (044) 3075203
Loma De Gato Marilao, Bulacan Mobile Nos.: 09171246026/09166446517 332 CP GARCIA ST COR. LIWAYWAY ST. MAGSAYSAY, TONDO MANILA
Smart: 0908-669-2136
FIRE ALARM SYSTEM A B C

12.22

5.89 0.69 5.64

0.72 2.47 2.70 2.14 2.71 0.79

1.01
2.79
T&B T&B

1.82
BEDROOM 1 BEDROOM 2
SD SD

4.41
FDAS

5.92
2

SD

1.69
2 DOWN

0.72

0.91

18.37
16
15

20.36
14
13 T&B
12

2.29
11
P
10
9

6.09
8
7
6
5
SD

4.44
4
3
BEDROOM 3
2
1

UP
SD

0.55
2.63

1.48
3
BALCONY EXTENSION
2.02
FOR 2ND FLOOR
BALCONY

0.49 3.46 1.23

4.69 1.50 0.54 2.44 0.61 1.38

11.16

FIRE DETECTION AND ALAM SYSTEM

M 2ND TO 3RD FLOOR PLAN


2 SCALE: 1:100MTS

PCBJR CONSTRUCTIONS SERVICES PROPOSED FOUR STOREY RESIDENTIAL HOUSE RENOVATION


ENGINEERS - CONTRACTOR - DESIGNERS 2ND TO 3RD FLOOR FDAS WORKS
Email Add; pcbjrcons74@[Link] MR & MRS : JOSEPH TAN
jr02_2005@[Link]
Blk 403 Lot-5 P4 Hydros St., Heritage Homes Office No: (044) 3075203
Loma De Gato Marilao, Bulacan Mobile Nos.: 09171246026/09166446517 132 CP GARCIA ST COR. LIWAYWAY ST. MAGSAYSAY, TONDO MANILA
Smart: 0908-669-2136
FIRE ALARM SYSTEM A B C

13.36

0.78 5.65 0.76 5.31 0.87

1
T&B

3.05
T&B

3.06
BEDROOM 1 BEDROOM 2
SD SD

9.54
4.82
FDAS
3

6.48
SD

1.85
2

0.99
DOWN

0.79

20.09
16
15

22.21
14
13 T&B

2.67
12
11
P
10
9

6.66
8
7
6 SD

10.55
5

4.67
4 BEDROOM 3
3
2
1
UP
SD

SERVICE GATE
2.88

2.22
3
2.16

BALCONY

0.54 2.27 0.97 1.35 1.64 0.59 2.66 0.67 1.51

12.20

FIRE DETECTION AND ALAM SYSTEM

M 4TH FLOOR PLAN


3 SCALE: 1:100MTS

PCBJR CONSTRUCTIONS SERVICES PROPOSED FOUR STOREY RESIDENTIAL HOUSE RENOVATION


ENGINEERS - CONTRACTOR - DESIGNERS 4TH FLOOR FDAS WORKS
Email Add; pcbjrcons74@[Link] MR & MRS : JOSEPH TAN
jr02_2005@[Link]
Blk 403 Lot-5 P4 Hydros St., Heritage Homes Office No: (044) 3075203
Loma De Gato Marilao, Bulacan Mobile Nos.: 09171246026/09166446517 132 CP GARCIA ST COR. LIWAYWAY ST. MAGSAYSAY, TONDO MANILA
Smart: 0908-669-2136
FIRE ALARM SYSTEM A B C

13.36

6.44 0.76 2.34 3.83

1
T&B

3.05

3.06
KITCHEN

FDAS
3
SD

4.85
CONNECTED TO
SMOKE DETECTOR

P
ON 4TH FLOOR

1.82
2

0.79
DOWN

22.27

22.30
19.25
6.39
14.36

2.42
CCTV ROOM

3
0.86

BALCONY
2.09

2.75 9.32

12.08

FIRE DETECTION AND ALAM SYSTEM

M ROOF DECK PLAN


4 SCALE: 1:100MTS

PCBJR CONSTRUCTIONS SERVICES PROPOSED FOUR STOREY RESIDENTIAL HOUSE RENOVATION


ENGINEERS - CONTRACTOR - DESIGNERS ROOF DECK FDAS WORKS
Email Add; pcbjrcons74@[Link] MR & MRS : JOSEPH TAN
jr02_2005@[Link]
Blk 403 Lot-5 P4 Hydros St., Heritage Homes Office No: (044) 3075203
Loma De Gato Marilao, Bulacan Mobile Nos.: 09171246026/09166446517 132 CP GARCIA ST COR. LIWAYWAY ST. MAGSAYSAY, TONDO MANILA
Smart: 0908-669-2136

GROUND FLOOR PLAN
SCALE:                                                          1:100MTS
0.51
1.94
0.51
2.67
11.54
5.45
3
4
2ND TO 3RD FLOOR PLAN
SCALE:                                                          1:100MTS
11.16
T&B
T&B
T&B
BEDROOM 3
BE
FIRE ALARM SYSTEM      
4TH FLOOR PLAN
SCALE:                                                          1:100MTS
12.20
BEDROOM
FIRE ALARM SYSTEM      
ROOF DECK PLAN
SCALE:                                                          1:100MTS
12.08
22.30
T