CS405 User Guide
CS405 User Guide
0X Rev 2 1
USER GUIDE
[Link]
System Setup
QRS-Card Cardiology Suite 4.0 Overview
The QRS-Card Cardiology Suite is a state-of-the-art ECG device(s) which when interfaced to an IBM ®
compatible personal computer converts the computer into a highly sophisticated Cardiology Suite (Resting ECG,
Stress ECG system, Holter ECG, Ambulatory Blood Pressure Measurement and Spirometry System). Physicians can
run Resting, Stress, Holter, Blood Pressure and PFT tests on patients using a standard Desktop or a notebook computer.
Results of the tests can be viewed on the computer color screen and can be printed automatically (or on demand) at any
time during a test. The results of the tests can be saved on the computer hard disk for future referral or report
generation purposes.
The QRS-Card Cardiology Suite is programmable for treadmill and Ergometers controls. Input of blood pressure
can be performed automatically (screen prompts or direct interface to BP device) at predefined intervals.
WARNINGS
US Customers will be supplied with ONLY software supplied by the device manufacture
(and not the Cardiology Suite ABMP software module).
1. Ambulatory Blood Pressure Recorder
2. Blood Pressure cuff
3. Recorder Carrying pouch
4. Data cable (serial or USB)
5. QRS-Card Cardiology Suite Software
6. User Guide (Supplied on Software CD)
7. Quick Reference Card
8. USB Security Key with Product ID Number (PID)
* For Hardware Installation and Setup see Appendix X
Spirometry
WARNINGS
US Customers will be supplied with ONLY software supplied by the device manufacture (and
not the Cardiology Suite Spiromtery software module).
1. Spirometer
2. Disposable Mouth Piece
3. Data cable (Serial or USB)
4. QRS-Card Cardiology Suite Software
5. User Guide (supplied on software CD)
6. Quick Reference Card
7. USB Security Key with Product ID Number (PID)
* For Hardware Installation and Setup see Appendix X
1. Switch on and boot up your computer with Windows XP, Window 2000 or Windows Vista
2. Insert the QRS-Card Cardiology Suite software CD into the CD drive.
3. Follow the instructions on the screen
4. Once the installation is complete, you are ready to start using your computer for Resting ECG, Stress ECG,
Holter ECG, 24 hour BP and Spirometry .
NOTE: 1. Write down the Product ID (PID) of your QRS-Card ECG device written on the USB Security
Key and also on the back of your QRS-Card (or provided by dealer or distributor). For Demo software Tutorial the
PID is 0001-0001-2000-DEMOU .
Press "CTRL F1" or Select from pulldown menu "HELP" then "About"
1. Connect QRS-Card ECG machine to your computer USB port (or serial port).
(See Appendix X for more help)
2. Start QRS-Card Cardiology Suite Software on your computer
3. Perform one time Setup for your Resting ECG
( File/Resting/Setup or Press CTRL F2 . See Appendix X for more details)
4. Press Resting ECG button (or Hot key F2 ) on the Main Software Screen
5. Type in Patient demographic data
(if Setup screen is displayed then press OK to go to patient demographic data input)
6. Press OK button to start acquire Resting ECG
7. ECG report will be printed manually or automatically
(Auto or Manual print depends upon printing preference under Resting Setup)
Resting DataView
A
SETUP FOR AUTO PRINT:
For Auto Report Print to work: Start Resting Test
a. Printer MUST be attached to the computer
b. Under Resting/Restup (CTL+F2)
i) Print ECG Report Must be checked off
ii) Type of Report
(e.g 12 Lead Standard) must be selected
B
Enter Patient Data
C AUTO PRINT
Must be defined
in Resting Setup
MANUAL PRINT
1. Connect QRS-Card ECG machine to your computer USB port (or serial port).
(See Appendix X for more help)
2. Start your QRS-Card Cardiology Suite Software on your computer
3. Perform one time Setup for your Stress ECG
( File/Stress/Setup or Press CTRL F3 )
See Appendix X for more details
4. Press Stress ECG button (or Hot key F3 ) from the Main Software Screen
5. Type in Patient demographic data
(if Setup screen show then press OK to go to patient demographic data)
6. Press OK button to start acquiring Stress ECG
7. ECG report will be printed after the completion of the Stress Test
Save Demand Finish
Advance Begin Enter Pause
Annotate Print Test
Stage Recovery BP Protocol
Strip
Stress ECG - Acquisition
TREND
HR, BP, ST
SPEED/ELEV
ARRHYTHMIA / RHYTHM
Protocol
Phase Stage
Stress ECG - Acquisition BP
Speed
(Pre, Exercise, METS Stage Time
or Recovery) Elevation Phase Time Heart Rate Target HR
Reference,85%,100%
Page View Full Page /
Complex Strips Trend
Rhythm
FULL DISCLOSURE / RHYTHM / TREND
RHYTHM TREND
Start
Stress Test
A
Pre Test
Phase
C. Acquire Pre Test Phase ECG Perform HYPER Advance
Pre Test C VENT Stage
Exercise
Perform
Phase
Exercise D STAGE E2
Phase ECG
2
STAGE E3
Recovery
STAGE "X"
Phase
Perform
Recovery E
Phase ECG RECOVERY Advance
Phase
3
Complete
Note: Complete ECG for the COMPLETE Stress Test is SAVED Stress F
to computer hard disk which then can EDITED/VIEWED/ Test
PRINTED Manually or Automatically.
Print Stress
Sumary Reports G
Multiple Style Reports
WARNINGS
Supplied for use only to outside US Customers
1. Connect QRS-Card ECG machine to your computer USB port (or serial port).
(See Appendix X for more help)
2. Start your QRS-Card Cardiology Suite Software on your computer
3. Perform one time Setup for your HiRes ECG
( File/HiRes/Setup or Press CTRL F4 )
See Appendix X for more details
4. Press HiRes ECG button (or Hot key F4 ) from Main Software Screen
5. Type in Patient demographic data
(if Setup screen show then press OK to go to patient demographic data)
6. Press OK button to start acquiring HiRes ECG
7. ECG report will be printed after the completion of the Stress Test
Note: In addition to placing limb leads at normal place on patient body, V1-V6 leads are places differently
then in Resting or Stress ECG.
V1 - +X
V2 - -X
V3 - +Y
V4 - -Y
V5 - +Z
V6 - -Z
HiRes Acquisition Screen
WARNINGS
US Customers will be supplied with ONLY software supplied by the device manufacture (and not the
Cardiology Suite ABMP software module).
Rest ECG Stress ECG Hi-Res ECG Holter ECG ABP Spirometry Help
Search by Delete
Name, ID Open Patient Print Add Patient
or Date Report New Patient
Test Report
Patient Preview
Database
QRS-Card Cardiology Suit Software Master screen is divided into following sections:
1. Pull Down Menu Selection for various items (File, Utility, Logs and Help)
2. Buttons to QUICKLY access Test or to obtain Help (Resting, Stress, HiRes, Holter,
AMPB, Spriometry & Help)
3. Folders for Patient Names and Test Database
4. Patient Database tools (Search, Open, Print, Email, Add New Patient, Delete Patient)
5. Test Report Preview
Database Tools:
Sort Test
The ECG Tests can be sorted by name , patient ID or date acquired by clicking on the respective
buttons (Partial name or date sort can be typed in the empty space between the database listing and
the tool bar buttons)
Open Test
Use the Open Test command to retrieve a previously saved Test from the QRS database. After selecting
test, The Open Test command can be executed as follows:
Print Test
Use the Print Test command to save and print the selected ECG Test to the QRS database and local printer.
The Print Test command can be executed as follows:
Mail Test
The Mail Out option allows the user to E-mail ECG Test.
Delete a Patient
Highlight the patient or the test to be deleted from the database the execute the following command:
Note: To quickly search for a Name, ID or Date in a large patient database, type partial name, ID or data to jump
to the closet match.
RESTING ECG
Topics
Modes of Operation
Starting a Resting ECG (Acquisition Mode)
Viewing a Resting ECG (Dataview Mode)
Resting ECG Setup
=====================================================
Modes of Operation
During normal operation of the QRS-Card ECG the system performs in either of three modes:
Standby Mode
Standby Mode is while QRS-Card Cardiology Suite Master screen is open and no selection of a test (new ore
review) has been made.
During this mode certain operation like patient search, adding a new patient or delete a patient can be
performed.
Acquisition Mode
The Acquisition Mode supplies the functionality to acquire Resting ECG data. The monitor mode displays
During this mode patient is attached to the QRS-Card and the ECG data is seen in real-time on the computer
screen.
Dataview Mode
The Dataview mode supplies the functionality to view previously acquired ECG data. Open a patient record
to access the Dataview Screen. For more details see Open Test Record.
Resting DataView
Save Strip option is only applicable when selection under Resting setup:
Exit when all task completed is unchecked.
Note: Multiple Resting ECG traces can be saved under this setup.
Print ECG:
During normal Resting ECG this options is not necessary as 10 Seconds ECG trace is
automatically saved and can be printed automatically (or manually)
Note: Only one kind of report can be printed with this option and it requires a HP PCL5 printer
attached to computer for printing this report
Finish Test:
During normal Resting ECG this options is not necessary as after 10 Seconds ECG trace Resting
ECG acquisition is automatically terminated.
This Print button is only applicable when selection under Resting Setup:
Exit when all task completed is unchecked.
To view (or edit) a Resting ECG test, highlight from Main Screen the ECG Test desired then click on the
button on the toolbar. OR
Double click on the Test to be reviewed.
When a Resting test record is opened, the Resting Dataview screen is displayed. Information about the
patient can be viewed and/or edited, data from the test viewed and reports printed. An outline of the
features and options displayed on the Resting Dataview screen is given below, along with any available
links to other relevant topics.
Resting DataView
Resting DataView
Edit
Use the Edit option to view or edit information about the patient and trace recalled from the database. The Edit
option can be executed by the following methods:
View
Page Window
Clicking on the blue in the upper right hand corner or the window will cause the toolbar to be
displayed. Clicking on the crossed out will hide the toolbar.
Rhythm Window
Summary
Pressing summary button provides summarized data for ECG measurements and automatic ECG
Interpretation.
Table
This table provides different amplitude measurements from all 12 ECG leaads
General
This selection provides ECG Complex measurements. Moving measurements marker
(using left mouse button) user can manually over ride the automatic ECG measurements
P Wave
This provides P wave measurement markers. Left mouse button can be used to move the
marker to over ride automatic P wave measurements.
QRS Wave
This provides QRS Complex measurement markers. Left mouse button can be used to
move the individual marker to over ride automatic QRS Complex measurements.
T Wave
This provides T wave measurement markers. Left mouse button can be used to move the
marker to over ride automatic T wave measurements.
Hypertrophy
Provides Hypertrophy scores for Sokolow Lyon, Cornell and Estes.
Interpretation
Provides Computer generated Automatic ECG Interpretation. Typing free text or
accepting Statements from the Statement Libarary can over ride this Automatic ECG
Interpretation box.
Note: For the Automatic Computer Interpretation to work in the Resting test this option
has to be selected in the Resting Setup.
The Interpretation property sheet shows the computer-generated interpretation. The user
can also enter their own interpretation.
Click on the arrow from the computer interpretation box to enter that into the Physician's
Interpretation box. Other interpretations are available in the Statement Library on the
right of the screen. Select the statement desired and click on the arrow to transfer it over
to the Physician's Interpretation box.
If the computer interpretation is not appropriate and no statements from the library can be
found to describe the test record, the physician can add his own interpretation by simply
clicking in the Physician Interpretation box and starting to type.
In a view-only box at the bottom of the screen, the date and time of the computer-
generated interpretation is displayed. If the computer interpretation is not used, the name
of the analyst who overread the interpretation and the physician that confirmed it, along
with the date and time, can be entered.
Report
Checked Off reports can be printed (automatically or manually) to printer attached to the computer.
If selection is made for PDF File Viewer then report will print as PDF file to the computer screen.
Save option button from Adobe Acrobat reader will make the report saved in PDF format, which
can be printed or emailed, if required by the user.
Note: In order to print PDF File Viewer to computer screen, installation of Adobe Acrobat Reader
6.0 or higher on user computer is required (also make sure that correct version of Acrobat Reader
is selected under \Utility\Configuration\Option\PDF . To make sure select Detect )
patient.)
ECG Filter
Electrical Interference
Allows the user to apply a 50Hz or 60Hz filter to smooth out the signal. If desired, the filter can
also be turned off.
Artifact Rejection
If the Artifact Rejection option is chosen, artifacts, like those caused by muscle twitches, will not
be assigned as peaks.
Baseline Drift Reduction
Drift of the baseline will be minimized.
Default Reports:
Checked Off reports can be printed (automatically or manually) as default reports to printer
attached to the computer.
ECG Acquisition
Recorder
Defines if the signal is coming from a QRS Card, a simulated device (QRS demo) or a remote QRS Card.
Sample Rate
Defines the sampling rate, per second.
Length
Defines the length of the ECG trace, in seconds, that is saved.
Average Cycles
Defines the number of beats averaged to make a complex ECG.
Screens
Defines Default parameters for Screen display values e.g. Gain, Speed, Lead Display etc for
Acquisition and Dataview Screens. See Appendix X for more help and details.
Reset Button
Selecting the Reset button will reset all parameters to their default positions.
STRESS ECG
Topics
Modes of Operation
Starting a Stress ECG (Acquisition)
Viewing a Stress ECG (Dataview)
Stress ECG Setup
===================================================================
Modes of Operation:
During normal operation of the QRS-Card ECG the system performs in either of three modes:
Standby Mode
Standby Mode is while QRS-Card Cardiology Suite Master screen is open and no selection of a
test (new ore review) has been made.
During this mode certain operation like patient search, adding a new patient or delete a patient can
be performed.
Acquisition Mode
The Acquisition Mode supply functionality to acquire Stress ECG data (in real-
time). The monitor mode displays an icon, , in the left hand corner of the title bar.
During this mode patient is attached to the QRS-Card and the ECG data is seen in real-
time on the computer screen.
Dataview Mode
The Dataview mode supplies the functionality to view previously acquired Stress ECG data. Open
a patient record to access the Dataview Screen. For more details see Open Test Record.
Save Demand Finish
Advance Begin Enter Pause
Annotate Print Test
Stage Recovery BP Protocol Page View Full Page /
Strip Complex Strips Trend
Rhythm
FULL DISCLOSURE / RHYTHM / TREND
Stress ECG - Acquisition
Protocol
Phase Stage
Stress ECG - Acquisition BP
Speed
(Pre, Exercise, METS Stage Time
Elevation Phase Time Target HR
or Recovery) Heart Rate Reference,85%,100% Stress DataView - Page/Rhythm/Trend
From the Acquisition Screen select File > Stress > Perform Test OR
TREND
HR, BP, ST
SPEED/ELEV
ARRHYTHMIA / RHYTHM
Protocol
Phase Stage
Stress ECG - Acquisition BP
Speed
(Pre, Exercise, METS Stage Time
or Recovery) Elevation Phase Time Heart Rate Target HR
Reference,85%,100%
Clicking on the blue in the upper right hand corner or the window will cause the toolbar to be
displayed. Clicking on the crossed out will hide the toolbar. (see page X under Resting ECG for more
details)
Advance Stage Begin Recovery Blood Pressure Save Strip Print ECG Pause Protocol Finish Test
In general QRS-Card Stress ECG Test has three phases. These Phases are:
1. Pre-Test Phase
2. Exercise Phase
3. Recovery Phase
Note: User Intervention is required in moving during Stages while in Pre-Test mode. While Exercise and
Recovery stages are timed e.g Each Exercise Stage in Bruce protocol is 3 minutes each.
Note: The Advance Stage command can only be accessed when a Stress Test is running.
Use the Advance Stage command to advance the Stress Test to the next Stage. The Advance Stage
command can be accessed the following way:
This button can be used to acquire Pre-Test Stage ECG s. This button can also be used to advance Stages
while in Exercise Phase or in Recovery Phase.
To manually enter Blood Pressure Press button on the Stress Status Bar.
To annotate or mark a Strip to print during final reports press button on the Stress Status Bar
To print a real-time ECG Report press button on the Stress Status Bar.
To pause (and manually control) the exercise stage and the protocol press button on the Stress Status
Bar.
Note: Pressing this Pause Protocol Button will display four additional buttons on the Stress Status bur. This
additional buttons are then used to manually control the Exercise Device (treadmill or Ergometer)
To complete the test (or Stop a test) press button on the Stress Status Bar.
This button is usually pressed while in RECOVERY phase. However this button can be pressed anytime during a test to
FINISH a test or to STOP a Test.
NOTE: In order to Stop a Test in an EMERGENCY SITUATION use TREADMILL EMERGENCY STOP
BUTTON.
REPORTS:
Checked Off reports can be printed (automatically or manually) to printer attached to the computer.
If selection is made for PDF File Viewer then report will print as PDF file to the computer screen (Installation of
Adobe Acrobat 6.0 or higher on computer is required). Save button from Adobe Acrobat reader will make the report
saved in PDF format, which can be printed or emailed, if required.
Edit Selection
This selection is used to review (and edit) any patient demographics information
and ECG device information. Information is subdivided into:
Patient
Test
Medication
Signal
Note: To see more about Editing and Viewing of Patient demographics information see
Appendix X page number Y
View Selection
This selection is used to review (and edit) acquired Stress Test ECG data in
various formats.
RHYTHM TREND
Page tab:
This selection shows full disclosure view of the complete stress test.
Complex tab:
Strips Tab:
Strip shown with time stamp marked in YELLOW are the one, which
are ready to print. These strips can be marked and unmarked by using
the tool bar buttons for marking/unmarking.
Summary Selection
This selection is used to review Stress Test Summary Data. This data include Stress
Summary, tabular data for Stress Test and Summarized Stress Test Interpretation.
Summary Tab
This selection shows Summary of Stress test and the reason for the termination of the
Stress Test (user has the option to overwrite their comments for the Test termination).
Table Tab
This selection shows Stress Test Summary in a tabular format
Interpretation Tab
This selection shows summary of computerize Interpretation of the Stress Test. User has
the option to overwrite the final Stress Test Interpretation with their own interpretation.
Report Selection
Checked Off reports can be printed (automatically or manually) to printer attached to the
computer.
If selection is made for PDF File Viewer then report will print as PDF file to the computer
screen. Save button from Adobe Acrobat reader will make the report saved in PDF
format, which can be printed or emailed, if required.
Note: In order to print PDF File Viewer to computer screen, installation of Adobe
Acrobat Reader 6.0 or higher on user computer is required (also make sure that
correct version of Acrobat Reader is selected under \ Utility \ Configuration \
Option \ PDF . To make sure select Detect )
From the Acquisition Screen select File > Stress > Setup OR
Click on the Stress ECG icon. If the "Show This Window" in the Stress Setup has been previously
checked, the Stress Setup dialog box will automatically be displayed. See below.
Executing Setup causes the system to display the Stress dialog box.
Blood Pressure
Defines whether or not a Blood Pressure reading will be used and if it is, whether it will by taken
automatically by the machine or whether the program will prompt the user to enter the BP
manually.
If NO BP is selected, the user will NOT be prompted for BP input unless the BP tool button is
manually executed.
Display Options
Show This Window
If checked, the Stress dialog box will appear when accessing the Stress Test (File > Stress >
Perform Test or clicking on the Stress ECG icon). If not checked, the Stress ECG Patient
Information dialog box will appear first when accessing the Stress Test.
Show Electrode Position Diagram
If checked, the electrode positioning diagram will be displayed after the Stress ECG Patient
Information dialog box and before the Stress Test starts.
Arrhythmia Screen
If checked, the Arrhythmia screen will be displayed during the Stress test.
Trend Screen
If checked, the Trend screen will be displayed during the Stress Test.
ST Segment Display
This option selects the display lead for the ST Trend Window. Selecting Normal provides the
display of ST for the user selected lead.
The Maximum ST Elevation or Depression Lead option automatically displays the ST values for the
lead that has either the maximum elevation or the maximum depression.
The Maximum ST Elevation Lead option automatically displays the ST values for the lead which
has the maximum ST elevation.
The Maximum ST Depression Lead option automatically displays the ST value for the lead which
has the maximum ST depression.
ECG Filter
Electrical Interference
Allows the user to apply a 50Hz or 60Hz filter to smooth out the signal. If desired, the filter
can also be turned off.
Artifact Rejection
If the Artifact Rejection option is chosen, artifacts, like those caused by muscle twitches,
will not be assigned as peaks.
Baseline Drift Reduction
Drift of the baseline will be minimized.
Reports
Demand
If desired, a printout of the ECG trace can be obtained while the test is running. Chose the number
of pages to be printed ( 1 to 6 pages or a continuous printout). Start the Stress test. Click on the
Print ECG icon and the printout will start from that point. If Continuous is chosen, the printout will
continue until the Print ECG icon is clicked again.
Protocol
If checked, an ECG trace will be printed for each time specified by the protocol.
Final
Specifies the type(s) of final reports.
Target Heart Rate
Defines whether the Target Heart Rate is to be calculated from the patient s age or be manually
assigned.
ECG Acquisition
Recorder
Defines if the signal is coming from a QRS Card, a simulated device (QRS demo) or a remote QRS
Card.
Sample Rate
Defines the sampling rate, per second.
Length
Defines the length of the ECG trace, in seconds, that is saved.
Average Cycles
Defines the number of beats averaged to make a complex ECG.
Screens
Defines Default parameters for Screen display e.g. Gain, Speed, Lead Display etc for
Acquisition and Dataview Screens. See Appendix X for more help and details.
Protocol Editor
See Protocol Editor
Defining a New Protocol
Protocol Information
Updating a Protocol
HiRes ECG
WARNINGS
Usage of HiRes ECG Software is ONLY customer Outside of US
Topics
Modes of Operation
Starting a Resting ECG (Acquisition Mode)
Viewing a Resting ECG (Dataview Mode)
HiRes ECG Setup
======================================================
Start a Hi-Res Test by one of the following methods:
From the Acquisition Screen select File > Hi-Res > Perform Test. OR
To view (or edit) a HiRes ECG test, highlight from Main Screen the ECG Test desired then click on the button
on the toolbar. OR
Double click on the Test to be reviewed.
When a Resting test record is opened, the HiRes Dataview screen is displayed. Information about the patient can be
viewed and/or edited, data from the test viewed and reports printed. An outline of the features and options displayed on
the Resting Dataview screen is given below, along with any available links to other relevant topics.
Edit
Use the Edit option to view or edit information about the patient and trace recalled from the database. The Edit
option can be executed by the following methods:
View
Pressing View button provides ECG data in various formats. These views are:
Rhythm View
Complex View
Filtered Complex View
Vector Magnitude view
Summary
Pressing summary button provides summarized data for ECG measurements and automatic ECG
Interpretation.
Report
Checked Off reports can be printed (automatically or manually) to printer attached to the computer.
HI-RES SETUP
The Setup command is used to define various parameters for running a Hi-Res Test. The Setup command
can be accessed by two methods:
From the Acquisition Screen select File > Hi-Res > Setup OR
Click on the Hi-Res ECG icon. If the "Show This Window" in the Hi-Res Setup has been previously
checked, the Hi-Res Setup dialog box will automatically be displayed.
Executing Setup causes the system to display the dialog box.
Sample Rate
Defines the sampling rate, per second.
Length
Defines the length of the ECG trace, in seconds, that is saved.
Average Cycles
Defines the number of beats averaged to make a complex ECG.
Reset
Selecting the Reset button will reset all parameters to their default positions.
The first time you use the PBI Holter system, you need to install the QRS-Card Cardiology Suite
software by using the Setup file on the PBI software CD. Once the software is installed, you will be able to
use the QRS-Card Cardiology Suite software for Holter ECG analysis and report printing. It will take
approximately 1 to 3 minutes for all of the directories to be created and for all of the files to be copied to your
computer hard disk.
In order to install the QRS-Card Holter System software, the following steps are required:
1. Switch on and boot up your computer with Windows XP, 2000 or Vista
2. Insert the QRS-Card Cardiology Suite software CD into the CD drive.
3. Follow the installation instructions on the screen.
5. Once the installation is complete, you are ready to start using your computer to perform Holter ECG
analysis and report printing
NOTE: Write down the Product ID (PID) of your QRS-Card Cardiology Suite software as the
PID and security key provided are required to use the [Link] Demo software Tutorial
the PID is 0001-0001-2000-DEMOU .
Welcome to QRS-Card Cardiology Suite this software offers advanced Holter technology with many
standard features in one package making it forefront of the industry. The advanced analysis techniques
used provide accurate results that can be systematically reviewed with minimal technician involvement.
Standard features include:
Accurate arrhythmia analysis
Preset artifact detection
Simple user interface
Fast load and analysis
Color coded beats and trends
Full disclosure (24 or 48 hours)
3-channel ST analysis
Split-screen superimposition
Multiple report formats
Multiple format page mode
Network compatibility
In Holter ECG data view mode click View button to view downloaded
Beats
Episodes
Page
Strips
The view Holter ECG module has been divided into the above parts to allow for easy navigation and
reclassification of the Holter ECG data.
Demographics
From the Dataview Screen select File > Demographics
When the Demographics option is executed; the Test Information dialog box will be displayed. This is used
to enter patient details.
Bins
All Beats are classified into Beats according to the software's algorithm.
The Beats that match a particular template can be viewed by selecting the desired tab displayed above the
template view window.
The Beats Screen displays Bins, this allows the user to view all similar beats within a single template as a
group and the beats from the selected Bin are displayed in the Rhythm Edit Screen.
R-R Interval
Episodes
List
Trend Screen
The Episodes Screen enables the user to review ECG data through the R-R interval window and the trend
window. Data in both windows is synchronized with the Rhythm Edit Screen as the user highlights the data.
As the ECG data is analyzed the Episodes are evaluated against predefined criteria and are stored in the
following categories:
Fastest Rates
Slowest Rates
Bradycardia
Pause
Isolated VEB
VEB Pair
VEB Run
Bigemny
SVEB Pair
SVEB Run
Recorder Episode
STe Abnormalities
The Strips screen allows the user to review and select which Episodes should be printed in the selected
report.
VPB
VPB Pairs
Bigeminy
SVPB
SVPB Pair
SVT
Pause/Asystole
Patient Episodes
Selected Strips
ST Episodes
Tachy/Brady
Fast rate
Slow rate
ST
List HR & ST Trend
The ST Table screen displays data from the 3 ST channels individually as well as summarized data in the
form of the ST List. The user can synchronize this data with the Rhythm Edit Screen.
The Page view Screen displays the ECG data between the duration of 1 - 30 minutes. The Page view
Screen and Rhythm Edit Screen are synchronized according to user selection of ECG data in Page view
screen.
Page view can be toggle between Full Page View or combination of Page and Rhythm Edit Screen.
This screen allows the user to easily identify many kinds of ECG abnormalities such as changes in P-R
interval, Q-waves, QRS conduction, and ST elevation, by rapidly displaying QRS complexes on top of the
preceding complex against a scale. Therefore the user can use the Superimpose mode to quickly determine
if beats have been classified correctly as any major fluctuations can be identified easily with the help of the
scale.
General
Supraventricular
Ventricular
Supraventricular Runs
Ventricular Runs
Bigeminy
Tachy/Brady
Interval Summary
Paced
Each table contains hourly results for each measurement and summary information for the entire record.
The HRV Screen gives the user graphical display of the ECG data through different parameters. This tool
assists the user to get an overview and analyze the ECG data at first glance.
Use the Blood Pressure command to enter patient blood pressure values data.
The system displays the Blood Pressure Entry Dialog Box when the Blood Pressure command is executed.
Enter the patient blood pressure using this screen. Once entered, the system updates the blood pressure
values.
The Rhythm Edit Screen allows the user to edit ECG data and reclassify beats. Beats classification
are indicated as follows:
To reclassify beats
1. Select the beat(s) from the Bins that you want to reclassify in the Rhythm Edit Screen.
To select a single beat click on the R-wave. To select multiple beats drag the R-waves that
you want to include.
2. Click the desired reclassify button that you want the beat to be reclassified to.
The Episodes Edit window allows the user to edit Episode data and reclassify Episodes.
Episodes classifications are indicated as follows:
To reclassify Episodes
1. Select the Episode(s) from the Episodes list that you want to reclassify in Rhythm Edit Screen
To select a single Episode click on the R-wave. To select multiple Episodes drag the R-
waves that you want to include.
2. Click the desired reclassify button that you want the Episode to be reclassified to.
The selected Episodes will be reclassified and the ECG Edit window will be updated
The selected episodes will be reclassified and the ECG Edit window will be updated
Display Strips
These control which ECG strips are displayed in the Strips mode.
· All - Use to display all strips for a category.
· Marked -Used to display all marked strips from a category.
· Unmarked - Used to display all unmarked strips from a category.
The Rhythm Edit Screen contains the following controls along the top of the window:
The multi-edit pane mode also contains the following additional controls:
· View - Used to select the number of panes displayed when the window is toggled to the multi-
pane mode Choices include 2x2, 4x2, 8x2, and 12x3 panes.
· Mark Row, Mark Page, Mark All - In the Beats and Episodes mode you can use these buttons
to select multiple Edit panes during the editing process.
Tip:
· Double-click in the ECG Edit window to toggle between single and multiple Edit panes.
You can reclassify individual beats displayed in the Page window using the procedure described
in Lessons: Reclassifying beats.
The selected beats will be reclassified and the Rhythm window will be updated.
press
The current time in the record and heart rate are displayed in the top left corner of the
Superimpose window. The ST markers are displayed as vertical lines in the Normal Beats
pane. During scanning the position of the slider at the bottom of the display is continuously
updated to reflect the relative position in the ECG record.
· Click Scan to stop scanning.
Tips:
· Use the slider to jump to different times in the record.
· To quickly re-scan a section of ECG while scanning, move the slider back the desired amount.
To view a table
· Click the table tab you want to display.
The HRV Screen functions give the user several options to view and analyze the ECG data with the help of
several graphical and statistical data views.
WARNINGS
US Customers will be supplied with ONLY software supplied by the device manufacture (and not the
Cardiology Suite ABMP software module).
Topics
Downloading ABMP data
Viewing and Printing ABPM Data
===============================================
Device
Specify the ABPM device used.
Port
Defines which empty com port the device will be using or if a file is being downloaded.
Record
Specifies the location of the data file to be downloaded, including the drive.
Show this Window
If this box is checked the Setup dialog box will appear before each ABPM download. If the box is
unchecked the Setup dialog box will not appear before each download. The download will proceed
in the predesignated fashion.
Default Report
Allows for selection of a default report at the time of download. The type of report can be changed
after the download by opening the ABPM test and selecting File > Print Report in the ABPM
Dataview screen.
To view (or edit) a ABPM test, highlight from Main Screen the ECG Test desired then click on the
button on the toolbar. OR
Double click on the Test to be reviewed.
When a ABPM test record is opened, the ABPM Dataview screen is displayed. Information about the
patient can be viewed and/or edited, data from the test viewed and reports printed. An outline of the
features and options displayed on the ABPM Dataview screen is given below, along with any available
links to other relevant topics.
Edit
Use the Edit option to view or edit information about the patient and trace recalled from the database. The Edit
option can be executed by the following methods:
Parameters on how the ECG was obtained, such as the sampling rate and use of filters, are contained on this
property sheet.
VIEW
Use View option to see ABPM data in four different ways:
ALL views seen simultaneously
Trend data only
Pie data only
Bar data only
Summary
Pressing summary button provides summarized data for ABPM measurements (Summary, Hourly, Actual
Measurements) and location to type physician Interpretation.
Report
Checked Off reports can be printed (automatically or manually) to printer attached to the computer.
UTILITY
Topics
Configuration
Physicians
Clinics
Technicians
Import Reports
Queue System
Rebuild
CONFIGURATOIN:
Configuration Section is used to setup various default parameters of using QRS-Card Cardiology Suite
Software. These options include:
Reporting
Database
Measurements
Options
GDT Interface
Real-Time Print
Email
REPORTING
Use the Reporting Configuration Property Sheet to set the default values for reporting ECG results.
Access the property sheet by the following method:
Select Utility > Configuration and click on the Reporting tab in the Configuration Setup property box.
Complex
Gain
Defines the Gain for ECG complexes to be printed on the Stress or Hi-Res ECG reports. Options
are 5, 10, 20 or 40 mm/mV.
Speed
Defines the Speed for ECG complexes to be printed on the Stress or Hi-Res ECG reports. Options
are 25, 50 or 100 mm/sec.
Lead 1
Defines the 1st complex lead to be printed on the Stress or Hi-Res ECG reports.
Lead 2
Defines the 2nd complex lead to be printed on the Stress or Hi-Res ECG reports.
Lead 3
Defines the 3rd complex lead to be printed on the Stress or Hi-Res ECG reports.
Rhythm
Gain
Defines the Gain for the ECG to be printed on the ECG reports. Options are 5, 10 or 20 mm/mV.
Speed
Defines the Speed for the ECG to be printed on the ECG reports. Options are 5, 10, 25 or 50
mm/sec.
Lead 1
Defines the 1st ECG Lead for the three lead ECG reports.
Lead 2
Defines the 2nd ECG Lead for the three lead ECG reports.
Lead 3
Defines the 3rd ECG Lead for the three lead ECG reports.
Hi-Res Complex/Vector Magnitude
Gain
Defines the Gain to be printed on Hi-Res reports. Options are 50, 100, 500 or 1000 mm/mV.
Speed
Defines the Speed to be printed on Hi-Res reports. Options are 50, 100 or 200 mm/sec
DATABASE
The Database property sheet allows the user to select the location of ECG data files and the
names of the individual files. This property sheet can be accessed by the following method:
Select Utility > Configuration and select the Database tab in the Configuration Setup property box.
Root:
Description: Defines the default root directory for all ECG data files.
Below the Root are all the default database file names.
Browse
The Browse button allows change of the root directory.
Reset
The Reset button sets all parameters back to their factory-set defaults.
Logging
Customer support may ask for this to be checked in order to pinpoint a problem.
Note: ECG database is in published SCP format. Each test is a separate file. These files are
stored in qrsdb4/files folder. It is important the user backup these individual SCP file for data
security purposes.
MEASUREMENTS:
Select Utility > Configuration and select the Measurements tab in the Configuration Setup property box.
The options contained in the Measurements Configuration property sheet are advanced settings to adapt the
system to special needs.
Reset
The Reset button sets all parameters back to their factory-set defaults.
OPTIONS:
Select Utility > Configuration and select the Option tab in the Configuration Setup property box
This option selects St Value s parameters, Multitask message display and PDF File Viewer Setup.
GDT:
Select Utility > Configuration and select the GDT tab in the Configuration Setup property box
This option is Only for German Medical Office EMR software Interface.
REALTIME PRINT
Select Utility > Configuration and select the Real Time Print tab in the Configuration Setup property box
This option is used to Enable or Disable Real Time Printer and to Setup Real Time Report Parameters.
EMAIL
Select Utility > Configuration and select the EMAIL tab in the Configuration Setup property box
This option is used to Setup Server Parameter for Sending and Receiving ECG s via Email.
PHYSICIAN
Select Utility > Physician then property box will appear
Names of attending and referring Physicians database are stored using this option.
Add:
Select to enter new Physician or Referring Physician name
Update:
Select to update on an existing entry in Physician database
Delete:
Select to delete an entry in Physician database
Export:
Select to Export a listing of an existing Physician database in text format
Import:
Select to Import an existing text format Physician list into Physician database
Clinics
Select Utility > Clinics then property box will appear
This option is use to Enter Clinics Names for a multi-practice medical office.
Add:
Select to Add a new Clinic name in the Clinic database
Update:
Select to update an existing Clinic name and address
Delete:
Select to Delete an existing Clinic name in the database
Export:
Select to Export an existing Clinic database to text format
Import:
Select to Import a text format Clinics names into Clinics database
Technician
Select Utility > Technician then property box will appear
This option is used to input Technician s name acquiring the ECG data
Add:
Select to Add a new Technician Name in the database
Update:
Select to Update an existing Technician name in the technician database
Delete:
Select to Delete an existing technician name from the database
Export:
Select to Export an existing technician database to text format
Import:
Select to Import a text format technician names into technician database
Import Reports
Select Utility > Import Reports then property box will appear
The Import Report option is used to import any new ECG report formats supplied by Pulse Biomedical or to
import any changes made to already existing report formats. The Import Report command can be accessed
by the following method:
Executing the Import Report command will cause the system to display the Import QRS Report dialog box.
To import a report format, highlight the desired report and click on Open. The new report is now ready for
use. To make changes to the format of an existing report go to Windows Explorer. In the directory
containing the QrsCard software, click on the report to be modified with the right mouse button. Select
Open. The existing report format will open on the Notepad. Make the desired changes and save them.
Return to the QrsCard software and the Import Report option. Highlight the modified report and click on
Open. The modified report is now ready for use.
Open
Highlight one or all reports then select this option to import report(s) into report database
Queue System
Select Utility > Queue System then property box will appear
The Queue System places the ECG traces from the patient Tests database in the queue system. At a later time, the user
can dump the queue to a printer, E-mail the traces, or export the traces to an external file (one not connected to the QRS
databases). Using the Queue system, the user can also receive ECG traces via E-mail or import a trace from an external
file.
After the test is complete, the Queue System command can be executed by the following method:
The system will display the QRS Queue System dialog box.
Dump Queue
Clicking on Dump Queue will dump the entire selected queue to the appropriate output device and
the Queue Dump dialog box appears. The Queue Dump dialog box shows the status of the queue
dump. Any errors that occurred will be listed.
Delete Queue
Clicking on Delete Queue will delete all items in the type of queue selected.
Reset Errors
Clicking on Reset Errors will reset any errors that occurred when dumping a queue.
Add
Clicking on Add will cause the system to display the appropriate Add dialog box for the
selected output device. See the Available Queues below for more information.
Update
Clicking on Update will bring up the Update QRS Queue Entry dialog box.
Details of the selected item can be edited in this dialog box. In particular, the type of
report selected for a particular queue item can be edited using this option.
Delete
Clicking on Delete in the bottom section of the dialog box allows the user to delete
individual items from a particular queue.
Print Queue
To add to the Print Queue, double-click on Printer under Available Queues in the Queue Detail Dialog Box
or highlight Printer and click on the Add button. The Add Entries to QRS Print Queue Dialog Box will be
displayed.
Select the test and the type of report desired, add any comments necessary and click on Add. Click on the
Close button to exit this dialog box. The selected traces will be copied to the Print Queue. Select Dump and
the traces will be printed.
To aid in finding an encounter, the user may sort the database by name, ID or date/time the encounter was
obtained by clicking on the appropriate heading name.
Mail In
The Mail In option allows the user to receive ECG traces via E-mail.
Note: For best results, connect to the Internet before entering the Queue System.
As the Queue System is accessed, a message "Retrieving message X or X" will appear if E-mail has been
sent to you since you last logged onto the Internet. The Mail In option in the Available Queue box will show
the number of messages.
Highlight Mail In and click on Dump Queue. The messages will be dumped directly into your database.
Note: Be aware that the time on the encounter is when the test was taken not when it was e-mailed or
dumped into the database.
Mail Out
The Mail Out option allows the user to E-mail ECG traces.
Note: For best results, connect to the Internet before entering the Queue System.
To add to the Mail Out Queue, double-click on the Mail Out option under Available Queues or highlight Mail
Out and click on the Add button. The Add Entries to QRS Mail Out Box Queue Dialog Box will appear.
Highlight the encounter to be E-mailed and using the directory option, enter the recipient E-mail address.
Click on Add to the queue. Click on Close to exit the dialog box. Click on Dump Queue to start the E-mail
process.
Queue Import
Selecting the Import Queue option will allow the user to import ECG trances from an external file.
To add to the Import Queue, double-click on Import under Available Queues or highlight Import and click on
the Add button. The Add Entries to QRS Import Queue Dialog Box will be displayed.
Select the file to be imported and the format to be used and click Apply.
Queue Export
Selecting the Export Queue option will allow the user to export ECG traces to an external file.
To export a file(S) double click on Export under Available Queues or highlight Export and click on the Add
button. The Add Entries to QRS Export Queue Dialog Box will be displayed.
Select the file(S) to be exported and click on Add Encounter. Click on the Close button to exit this dialog
box. The files will be copied to the Export Queue. Select Dump. The selected files will be exported into the
Windows Temporary (TAMP) Directory.
Rebuild
Select Utility > Rebuild then property box will appear
This selection is used to rebuild (Re-Index) a corrupted, bad database or merging of the database.
This selection can also be used if two or more database needs to be combined together into one
database (e.g copy both database *.SCP files into qrsdb4\files folder the select Rebuild
command)
LOGS MENU
Log files are created each time the STWIN program is run. This file keep track of all operation performed by
the user. More importantly this files keep logs of any errors occur during the usage of the program.
Viewing of the file can very helpful in finding any user problems with the program.
Status
Use the Status command to display the status log. The Status command can be executed by the following
method:
From the Logs Menu select Status .
When the Status command is executed the system displays the Log View Dialog Box. This log file shows
the most recent events the system executed.
Error
Use the Error command to display the error log. The Error command can be executed by the following
method:
From the Logs Menu select Error.
Executing the Error command causes The system displays the Log View Dialog Box when the Error
command is executed. This log file shows the most recent errors that the system encountered.
Note: Error Log file is the MOST IMPORTANT file for trouble shooting the QRS-
Card Hardware and software. During technical support call to PBI the information contain in this
file will assist PBI the most information to solve or diagnose the problem over telephone.