0% found this document useful (0 votes)
50 views1 page

Assignment 2

The document contains 18 questions about refrigeration and air conditioning topics including defining terms, representing processes on psychrometric charts, listing air filters and heat sources, explaining humidification, dehumidification, and occupant load calculation processes, differentiating between comfort and industrial air conditioning, and explaining summer, winter, and split air conditioning systems.

Uploaded by

missaakankshau
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views1 page

Assignment 2

The document contains 18 questions about refrigeration and air conditioning topics including defining terms, representing processes on psychrometric charts, listing air filters and heat sources, explaining humidification, dehumidification, and occupant load calculation processes, differentiating between comfort and industrial air conditioning, and explaining summer, winter, and split air conditioning systems.

Uploaded by

missaakankshau
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

AssignmentNo.

2 : Refrigeration and Air Conditioning


1 Define following Terms used in air conditioning 4 Marks
a) Sensible heat
b) Latent Heat
c) Sensible Heat factor
d) Bypass Factor
2 Represent Heating and Humidification process on Psychrometric chart. 2 Marks
3 Represent Cooling and Dehumidification process on Psychrometric chart. 2 Marks
4 Enlist various Air Filters used in Air Conditioning 2 Marks
5 Explain the process of Humidification by Air washing with neat sketch. 4 Marks
6 Explain Spray type Dehumidifier with neat sketch 4 Marks
7 Air is dehumidified from initial condition of 320c DBT and 80% RH to 250c DBT and 2 Marks
150c WBT. Find moisture removed and decrease in enthalpy of dry air.
8 With the help of Psychrometric chart find the properties of air at 260 c DBT and 50% 2 Marks
relative humidity
a) Dew Point temperature,
b) Wet Bulb Temperature,
c) Enthalpy of Air,
d) Sp. Humidity of air.
9 An office space is to be conditioned for 60 people. The outdoor conditions are the 4 Marks
dry bulb temperature 400c and 70% RH. Quantity of air supplied 0.4 m3/min/person
a) Capacity of cooling coil
b) Capacity of heating coil
c) Amount of water vapour removed per hour
Assume that inlet air has 200 c DBT and 60% relative humidity.
Air is conditioned first by cooling and humidification and then heating.
10 In cooling application, moist air enters a refrigeration coil at the rate of 100 kg of dry 4 Marks
air per minute at 350c and 50 % RH. The apparatus dew point temperature is 500c
and bypass factor is 0.15. Determine the outlet state of moist air and cooling
capacity of coil.
11 List the sources which contribute to Sensible Heat Gain in air conditioning. 4 Marks
12 List any four latent heat gain sources considered for cooling load calculations’. 2 Marks
13 Explain how Occupants load is calculated for Heat load calculation in Air 4 Marks
conditioning.
14 Differentiate between Comfort air conditioning and Industrial Air Conditioning. 4 Marks
15 Explain summer air conditioning system. 4 Marks
16 Explain Winter air conditioning system. 4 Marks
17 Explain Split Air conditioning system with neat sketch 4 Marks
18 Explain desirable properties of insulating material used in air conditioning system. 4 Marks

You might also like