0% found this document useful (0 votes)
134 views2 pages

Specsheet 75

The document provides specifications for a 75 kVA diesel generator set including details about the generator, engine, alternator, fuel system, lubrication system, cooling system, and control panel. Key specifications include a 75/60 KVA/KW rating, 3-cylinder inline diesel engine, 380-440V 50Hz 4-pole alternator, 150L fuel tank, 8.5L lube oil sump, and centrigual water cooling system.

Uploaded by

ahmadhafiz.eng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views2 pages

Specsheet 75

The document provides specifications for a 75 kVA diesel generator set including details about the generator, engine, alternator, fuel system, lubrication system, cooling system, and control panel. Key specifications include a 75/60 KVA/KW rating, 3-cylinder inline diesel engine, 380-440V 50Hz 4-pole alternator, 150L fuel tank, 8.5L lube oil sump, and centrigual water cooling system.

Uploaded by

ahmadhafiz.eng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Diesel Generator Set Specifications Sheet- 75 kVA

Generator Specifications:
Alternator Specification:
Genset Manufacturer Greaves Power
Voltage 380-440V
Genset Rating Prime Power
Frequency 50Hz
Genset Output ( KVA / KW ) 75 / 60
Current @ 0.8PF (Amps) 104.3
Genset Model GPW II-PII-75
Type 4 Pole , Rotating field
Engine rating or Max. Power at rated RPM, in
74.5 (101.2) Brushless (Permanent
KW (BHP) Exciter Type
Engine Model 3G11ITAG26 magnet optional)
6, fixed.
Engine Type TCAC
Leads: Quantity , type 12, re connectable (Optional)
No. of Cylinders / Cylinder arrangement 3 / Inline
Voltage regulator Solid State
Displacement (L) 3.66 Insulation Class H ,
Bore & Stroke (mm) 108 X 133 Temperature rise 125 Deg. C (Class H)
Compression ratio 16.8 Bearing: Quantity , type 1,Sealed
Rated RPM 1500 Flexible disc, closed
Coupling
coupled
Governor: Type /Class of Governing Mechanical/G2
Over speed trip (rpm) 1650 Voltage regulation : No load to full load 2 Phase sensing,±1%
One step load acceptance 100% of rating
Air cleaner type / Qty Dry / 01 Unbalance load capability 25% of rated current
Exhaust system
Standard scope of supply:
Maximum allowable back pressure, kPa 4.5
Engine with direct injection, water cooled engine,3 cylinder, in-line, 4 stroke,
rated at 1500 RPM, conforming to ISO 3046 / BS 5514 has the following
specifications:
- Mechanical FIP
- Mechanical governor / Electronic Governor (Optional)
Engine Electrical system: - Turbocharger, exhaust manifold, stainless steel exhaust flexible connection
Charging alternator Voltage / Current (DC) 12V / 35Amps - Radiator Cooled, with turbocharged after cooled
-Plate Type lube oil cooler
Starter Motor rated voltage (DC) 12 -Filters-fuel, lube oil
12V, 88 AH - Dry type replaceable paper element air cleaner
Battery Voltage (DC) / Capacity (AH) - Flywheel housing and flywheel to suit single bearing alternator
- Starting motor – Electric, battery charging alternator
- First fill lube oil and coolant
Fuel System: Alternator: Meccalte / (Optional -Stamford/ Crompton Greaves /equivalent)
Recommended Fuel
HSD -brushless alternator
- Self-excited, self-regulated
Fuel tank capacity ( Ltr) 150 - Class ‘H’ insulation limited to temperature rise of class H
- Salient pole revolving field
Fuel consumption - LPH at % load - Single bearing
100% 17.57 - Automatic voltage regulator
75% 12.63
Acoustic enclosure – Engine alternator assembly mounted on AVM with Silencer
50% 9.8 and S.S exhaust bellow suitably optimized to meet stringent sound & emission
25% 5.5 standards as laid down by MOEF / CPCB
- Base rail with draw-out type fuel tank is provided with a drain plug, air
Vent, inlet and outlet connections, level indicator, manhole etc.
Lubricating Oil system : - Sub-base fuel tank with 11 hours capacity at 75% load.
- 12/24 V dry, batteries with connecting leads and terminals
Lube oil sump capacity 8.5 -90% gloss RAL9003 white pure polyester powder coated, base in black colour.
Oil change period (Hrs) 500
Control panel: RAL 9003 W hite Powder coated control panel manufactured with
Oil consumption ( % of SEC) 0.2 CRCA sheet , Control Panel is having following features:
-W ater and lube oil drain outlets located on the outer surface- Leading to ease of
Oil filter quantity (Nos) /type 01 / spin on type maintenance and cleanliness.
 - MCCB of suitable rating with short circuit protection
15W40 - Controller which displays voltage, current, KW, PF, Frequency, KWh.
Recommended Oil Grade Greaves Maxtherm - Indicating lamps for “Load On” and “Set Running”
API CI4
- Current transformers of suitable ratings
- Copper cable of suitable capacity with incoming and
Oil Cooler Water cooled Outgoing terminations
- Control fuses duly wired and ferruled

Power cables: Uninyvin copper conductor cables between Alternator & Control
Cooling System : panel inside the canopy.
Cooling system is designed for max ambient
50
temp, Deg. C at rated load Literature:
Radiator System capacity, including engine, (L) 20 Ltr Operation Manual
General maintenance & installation Guideline
Water pump type Centrifugal, Gear Driven Foundation Drawing
Parts manual
Generator Controller (GADC-321)

CONTROLER TYPE FEATURES DISPLAY PARAMETER AUDIO VISUAL WARNING SHUT DOWN WITH AUDIO
VISUAL ANNUNCIATION
Compact and
microprocessor based fully
Engine Oil pressure Low Oil pressure Low Oil Pressure
configurable control Unit.

Greaves Advance Digital Graphic display Coolant temperature High Coolant temperature High Coolant temperature
Controller
The unique integrated DG
set controller Fuel level indication % Low Battery Voltage Engine Over speed

Incorporate both engine


and alternator parameter in Battery voltage Low fuel Level Engine underspend
one console
Fully configurable digital
out put Engine rpm Low Fuel

All parameter are settable Over load


DG set Running Hours
and password protected
Generator Volts –
Remote start Phase – Neutral & Under voltage
Phase - Phase
Generator Current Over voltage
(Amps)
Power factor Over frequency
KWHR Under frequency
KW

Optional Items:
Open Unit (For Export) Exhaust silencer-Hospital/ Residential grade,
stainless steel, Flexible pipe.
Cooling System: Heater Kit for -20 Deg. C Operation / Heater Kit for -30 [Link]
Fuel System: Flexible Fuel Lines / SS fuel lines / Fuel Pressure Gauge/fuel
Electrical Systems: Alternator Space Heater / Higher Rating Battery / Battery flow meter
Charger / Battery Heater / Copper Bus Bar / Sealable kW h / Earth Fault Relay /
Remote Annunciator / Remote monitoring / RTD/BTD Temperature Scanner Enclosed Unit:-Sound Enclosure – Super silent / External 990 Lt. Fuel Tank
AMF &Synchronizing System: AMF panel / AMF with Auto-synchronization Miscellaneous: Air Cleaner (Heavy Duty)/Air Cleaner Restriction Indicator
(Deep Sea / W oodward) Digital / Closed crankcase ventilation

Typical Enclosed GENSET Dimensions & weight

Model Rating Length(mm) Width(mm) Height(mm) Weight(kg)

GPWII-PII-75 75 2800 1150 1540 1270