Test Report issued under the responsibility of:
TEST REPORT
IEC 60335-2-15
Safety of household and similar electrical appliances
Part 2: Particular requirements for appliances for heating liquids
Report Number............................... : NBES140100003101
Date of issue .................................. : 2014-03-10
Total number of pages .................... 84
Applicant’s name ........................... : M.K. Eletrodomésticos Mondial S.A.
Address........................................... : Estrada da Volta, 1200 – 44245-000 – Conceição do Jacuípe/BA –
Brasil
Test specification:
Standard ......................................... : IEC 60335-2-15:2002 (Fifth edition) + A1:2005 + A2:2008 in
conjunction with IEC 60335-1:2010 (Fifth Edition)
Test procedure ............................... : Brazil Approval
Non-standard test method ………..: N/A
Test Report Form No. .................... : IEC60335_2_15I
Test Report Form(s) Originator .... : IMQ S.p.A.
Master TRF ..................................... : Dated 2012-03
Copyright © 2012 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .................... : Pressure Cooker
Trade Mark...................................... : None
Manufacturer .................................. : Zhongshan Aixin Electrical Appliance Co., Ltd.
1, Shengye Road, Xingpu Avenue, Maxin Industrial Zone, Huangpu
Town, Zhongshan, Guangdong, China
Model/Type reference .................... : PE-09, PE-12
Ratings............................................ : 220 V sample of PE-12: 220 V; 60 Hz; 900 W; Class I
127 V sample of PE-12: 127 V; 60 Hz; 900 W; Class I
220 V sample of PE-09: 220 V; 60 Hz; 800 W; Class I
127 V sample of PE-09: 127 V; 60 Hz; 800 W; Class I
Page 2 of 84 Report No. : NBES140100003101
Testing procedure and testing location:
Testing Laboratory: SGS-CSTC Standards Technical Services Co., Ltd.
Ningbo Branch
Testing location/ address ........................ : 1-5/F West No. 4 Building, Lingyun Industry Park, No. 1177
Lingyun Road, Ningbo National Hi-Tech Zone, Ningbo,
Zhejiang, China
Associated CB Laboratory: N/A
Testing location/ address ........................ :
Tested by (name + signature) ........: Peterman Pan
Approved by (name + signature) ...: Cindy Xia
Testing procedure: TMP N/A
Testing location/ address ........................ :
Tested by (name + signature) ........:
Approved by (name + signature) ...:
Testing procedure: WMT N/A
Testing location/ address ........................ :
Tested by (name + signature) ........:
Witnessed by (name + signature)..:
Approved by (name + signature) ...:
Testing procedure: SMT N/A
Testing location/ address ........................ :
Tested by (name + signature) ........:
Approved by (name + signature) ...:
Supervised by (name + signature) :
Testing procedure: RMT N/A
Testing location/ address ........................ :
Tested by (name + signature) ........:
Approved by (name + signature) ...:
Supervised by (name + signature) :
TRF No. IEC60335_2_15I
Page 3 of 84 Report No. : NBES140100003101
List of Attachments (including a total number of pages in each attachment):
1. Test report – 84 pages
2. Annex I – Photo documentation – attachement 23 pages
Summary of testing:
The provided samples were tested and found to meet the below standards:
IEC 60335-2-15: 2002 + A1: 2005 + A2: 2008
IEC 60335-1: 2010
After review, full tests were performed on 220 V sample of PE-12 and PE-09. Tests of clause 10, 11, 13,
15, 16, 17 and 19 were performed on 127 V sample of PE-12 and PE-09.
Tests performed (name of test and test clause): Testing location:
All tests above Refer to p. 2
Summary of compliance with National Differences
The requirements of national differences of Brazil were taken into account.
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
TRF No. IEC60335_2_15I
Page 4 of 84 Report No. : NBES140100003101
Test item particulars .................................................. : Pressure Cooker
Classification of installation and use ...................... : Portable appliance
Supply Connection..................................................... : Appliance coupler
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ............: N/A
- test object does meet the requirement ..................: P (Pass)
- test object does not meet the requirement............: F (Fail)
Testing ..........................................................................:
Date of receipt of test item .........................................: 2014-01-10
Date (s) of performance of tests ................................: 2014-01-10 to 2014-03-10
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see annex #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma is used as the decimal separator.
This document is issued by the company under its General Conditions of Service accessible at
[Link] Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that
information contained hereon reflects the Company’s findings at the time of its intervention only and within
the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document
does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of
this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated: (a) the results shown in this document refer only to the sample(s) tested and (b)
such sample(s) are retained for 3 months. This document cannot be reproduced except in full, without prior
approval of the company.
Name and address of factory (ies)........................... : Same as manufacturer
General product information:
The appliances were for household and indoor use only.
There were four models in this report: PE-12 (220 V sample and 127 V sample) and PE-09 (220 V sample and
127 V sample). PE-12 was identical with PE-09 except for the rated power input, rated capacity, heating
element and enclosure color. The 220 V sample was identical with the 127 V sample except for the rated
voltage, heating element, varistor and transformer. Details see photo documentation.
Two main PCBs for 220 V sample and 127 V sample were added for alternative. Compared to the original
Main PCB, the alternative main PCBs cancelled fuse link, X2 capacitor and varistor. Details see photo
documentation.
TRF No. IEC60335_2_15I
Page 5 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
5 GENERAL CONDITIONS FOR THE TESTS
Tests performed according to clause 5, e.g. nature P
of supply, sequence of testing, etc.
5.2 See Note 101 (IEC 60335-2-15:2002) N/A
The test of 19.101 is made after other tests N/A
5.3
(IEC 60335-2-15:2002)
5.101 Induction rice cookers, tested as motor-operated N/A
appliances (IEC 60335-2-15/A2:2008)
6 CLASSIFICATION
6.1 Protection against electric shock: Class I P
Class 0, 0I, I, II, III....................................... ..........:
6.2 Protection against harmful ingress of water IPX0 N/A
Wash boilers and livestock feed boilers shall be at N/A
least IPX3 (IEC 60335-2-15:2002)
7 MARKING AND INSTRUCTIONS
7.1 Rated voltage or voltage range (V)............. .......... : 220 V, 127 V P
Symbol for nature of supply, or................... ..........: N/A
Rated frequency (Hz) ................................. ..........: 60 Hz P
Rated power input (W), or .......................... ..........: 900 W for PE-12, 800 W for P
PE-09
Rated current (A) ....................................... ..........: N/A
Manufacturer's or responsible vendor's name, See copies of marking plates P
trademark or identification mark ................. ..........:
Model or type reference.............................. ..........: PE-12, PE-09 P
Symbol IEC 60417-5172, for class II appliances N/A
IP number, other than IPX0 ........................ ..........: IPX0 N/A
Symbol IEC 60417-5180, for class III appliances, N/A
unless
the appliance is operated by batteries only N/A
Symbol IEC 60417-5036, for the enclosure of N/A
electrically-operated water valves in external hose-
sets for connection of an appliance to the water
mains, if the working voltage exceeds extra-low
voltage
Appliances intended to be partially immersed in N/A
water for cleaning, marked with the maximum level
of immersion and with the substance of the
following: "Do not immerse beyond this level"
(IEC 60335-2-15:2002)
TRF No. IEC60335_2_15I
Page 6 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
For kettles : level mark or other means which N/A
indicate the rated capacity (IEC 60335-2-15:2002)
Unless they cannot be filled beyond their rated N/A
capacity (IEC 60335-2-15:2002)
Mark outside of the kettle if the level is not self- N/A
evident (IEC 60335-2-15:2002)
Marking on the appliance of the closed position of N/A
the lid of pressure cooker, if it is not obvious
(IEC 60335-2-15:2002)
Identification mark and model or type reference of N/A
stand for cordless kettles (IEC 60335-2-15:2002)
7.2 Warning for stationary appliances for multiple N/A
supply
Warning placed in vicinity of terminal cover N/A
7.3 Range of rated values marked with the lower and N/A
upper limits separated by a hyphen
Different rated values marked with the values N/A
separated by an oblique stroke
7.4 Appliances adjustable for different rated voltages, N/A
the voltage setting is clearly discernible
Requirement met if frequent changes are not N/A
required and the rated voltage to which the
appliance is to be adjusted is determined from a
wiring diagram
7.5 Appliances with more than one rated voltage or one N/A
or more rated voltage ranges, marked with rated
input or rated current for each rated voltage or
range, unless
the power input is related to the arithmetic mean N/A
value of the rated voltage range
Relation between marking for upper and lower limits N/A
of rated power input or rated current and voltage is
clear
7.6 Correct symbols used P
Symbol for nature of supply placed next to rated N/A
voltage
Symbol for class II appliances placed unlikely to be N/A
confused with other marking
Units of physical quantities and their symbols P
according to international standardized system
7.7 Connection diagram fixed to appliances to be N/A
connected to more than two supply conductors and
appliances for multiple supply, unless
TRF No. IEC60335_2_15I
Page 7 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
correct mode of connection is obvious N/A
7.8 Except for type Z attachment, terminals for connection to the supply mains indicated
as follows:
- marking of terminals exclusively for the neutral N/A
conductor (letter N)
- marking of protective earthing terminals (symbol N/A
IEC 60417-5019)
- marking not placed on removable parts N/A
7.9 Marking or placing of switches which may cause a N/A
hazard
7.10 Indications of switches on stationary appliances and By letters P
controls on all appliances by use of figures, letters
or other visual means ................................. ..........:
This applies also to switches which are part of a P
control
If figures are used, the off position indicated by the N/A
figure 0
The figure 0 indicates only OFF position, unless no N/A
confusion with the OFF position
7.11 Indication for direction of adjustment of controls N/A
7.12 Instructions for safe use provided P
Details concerning precautions during user P
maintenance
The instructions state that:
- the appliance is not to be used by persons P
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction
- children being supervised not to play with the P
appliance
For a part of class III construction supplied from a N/A
detachable power supply unit, the instructions state
that the appliance is only to be used with the unit
provided
Instructions for class III appliances state that it must N/A
only be supplied at SELV, unless
it is a battery-operated appliance, the battery being N/A
charged outside the appliance
Appliance incorporating an appliance inlet and intended to be immersed for
cleaning, instructions include the following : (IEC 60335-2-15:2002)
- the connector must be remove before cleaning N/A
TRF No. IEC60335_2_15I
Page 8 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- the appliance inlet must be dried before the N/A
appliance is used again
The instructions for use for appliances intended to N/A
be used with a connector incorporating a
thermostat, state that only the appropriate
connector must be used (IEC 60335-2-15:2002)
Unless, kettles are constructed so that a hazard cannot arise from boiling water
being ejected, the instructions for use include the following: (IEC 60335-2-15:2002)
- if the kettle is overfilled, boiling water may be N/A
ejected
The instructions for use for kettles filled through a lid aperture which is situated
below the handle, include the substance of the following: (IEC 60335-2-15:2002)
- Warning: "Position the lid so that steam is directed N/A
away from the handle"
- Warning: "Do not remove the lid while the water is N/A
boiling"
Instructions for cordless kettles state that the kettle N/A
is only to be used with the stand provided
(IEC 60335-2-15:2002)
If the kettle and stand of cordless kettles can be lifted together by gripping the
handle of the kettle, the instructions for use include the substance of the following:
(IEC 60335-2-15:2002)
- "Caution - Ensure that the kettle is switched off N/A
before removing it from its stand"
Instructions for feeding bottle heaters: N/A
- state that the food should not be heated for too N/A
long a period
- state how to check that the correct food N/A
temperature has not been exceeded
The instructions for use for appliances normally P
cleaned after use and not intended to be immersed
in water for cleaning, state that the appliance must
not be immersed (IEC 60335-2-15:2002)
Instruction for pressure cooker : (IEC 60335-2-15:2002)
- state that the ducts in the pressure regulator P
allowing the escape of steam should be checked
regularly to ensure that they are not blocked
- give details of how to open the container safely, P
and
- state that the container must not be opened until P
the pressure has decreased sufficiently
The instructions for use for egg boilers provided with a pricking device contain the
substance of the following : (IEC 60335-2-15:2002)
TRF No. IEC60335_2_15I
Page 9 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- Caution: "Avoid injuries from the egg pricker" N/A
Instructions for espresso coffee-makers incorporating a pressurized reservoir filled
by the user: (IEC 60335-2-15:2002)
- contain information for the safe refilling of the N/A
water reservoir and the substance of the following:
(IEC 60335-2-15/A1:2005)
- WARNING: The filling aperture must not be N/A
opened during use
The instructions including the substance of the following : (IEC 60335-2-15/
A2:2008)
This appliance is intended to be used in household and similar applications as: P
- staff kitchen areas in shops, offices and other P
working environments
- farm houses P
- by clients in hotels, motels and other residential P
type environments
- bed and breakfast type environments P
7.12.1 Sufficient details for installation supplied N/A
For an appliance intended to be permanently N/A
connected to the water mains and not connected by
a hose-set, this is stated
7.12.2 Stationary appliances not fitted with means for N/A
disconnection from the supply mains having a
contact separation in all poles that provide full
disconnection under overvoltage category III, the
instructions state that means for disconnection
must be incorporated in the fixed wiring in
accordance with the wiring rules
7.12.3 Insulation of the fixed wiring in contact with parts N/A
exceeding 50 K during clause 11; instructions state
that the fixed wiring must be protected
7.12.4 Instructions for built-in appliances:
- dimensions of space N/A
- dimensions and position of supporting and fixing N/A
- minimum distances between parts and N/A
surrounding structure
- minimum dimensions of ventilating openings and N/A
arrangement
- connection to supply mains and interconnection of N/A
separate components
TRF No. IEC60335_2_15I
Page 10 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- allow disconnection of the appliance after N/A
installation, by accessible plug or a switch in the
fixed wiring, unless
a switch complying with 24.3 N/A
7.12.5 Replacement cord instructions, type X attachment N/A
with a specially prepared cord
Replacement cord instructions, type Y attachment N/A
Replacement cord instructions, type Z attachment N/A
7.12.6 Caution in the instructions for appliances N/A
incorporating a non-self-resetting thermal cut-out
that is reset by disconnection of the supply mains, if
this cut-out is required to comply with the standard
7.12.7 Instructions for fixed appliances stating how the N/A
appliance is to be fixed
7.12.8 Instructions for appliances connected to the water mains:
- max. inlet water pressure (Pa) : N/A
- min. inlet water pressure, if necessary (Pa) : N/A
Instructions concerning new and old hose-sets for N/A
appliances connected to the water mains by
detachable hose-sets
7.13 Instructions and other texts in an official language English version checked P
7.14 Marking clearly legible and durable, rubbing test as P
specified
7.15 Markings on a main part On the bottom enclosure P
Marking clearly discernible from the outside, if P
necessary after removal of a cover
For portable appliances, cover can be removed or N/A
opened without a tool
For stationary appliances, name, trademark or N/A
identification mark and model or type reference
visible after installation
For fixed appliances, name, trademark or N/A
identification mark and model or type reference
visible after installation according to the instructions
Indications for switches and controls placed on or P
near the components. Marking not on parts which
can be positioned or repositioned in such a way that
the marking is misleading
7.16 Marking of a possible replaceable thermal link or N/A
fuse link clearly visible with regard to replacing the
link
8 PROTECTION AGAINST ACCESS TO LIVE PARTS
TRF No. IEC60335_2_15I
Page 11 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
8.1 Adequate protection against accidental contact with P
live parts
8.1.1 Requirement applies for all positions, detachable P
parts removed
Lamps behind a detachable cover not removed, if N/A
conditions met
Insertion or removal of lamps, protection against N/A
contact with live parts of the lamp cap
Use of test probe B of IEC 61032, with a force not P
exceeding 1 N: no contact with live parts
8.1.2 Use of test probe 13 of IEC 61032, with a force not Class II construction P
exceeding 1 N, through openings in class 0
appliances and class II appliances/constructions: no
contact with live parts
Test probe 13 also applied through openings in No such opening N/A
earthed metal enclosures having a non-conductive
coating: no contact with live parts
See Note 101 (IEC 60335-2-15:2002) N/A
8.1.3 For appliances other than class II, use of test probe N/A
41 of IEC 61032, with a force not exceeding 1 N: no
contact with live parts of visible glowing heating
elements
8.1.4 Accessible part not considered live if:
- safety extra-low a.c. voltage: peak value not N/A
exceeding 42.4 V
- safety extra-low d.c. voltage: not exceeding 42.4 V N/A
- or separated from live parts by protective N/A
impedance
If protective impedance: d.c. current not exceeding N/A
2 mA, and
a.c. peak value not exceeding 0.7 mA N/A
- for peak values over 42.4 V up to and including N/A
450 V, capacitance not exceeding 0,1 µF
- for peak values over 450 V up to and including N/A
15 kV, discharge not exceeding 45 µC
- for peak values over 15kV, the energy in the N/A
discharge not exceeding 350 mJ
8.1.5 Live parts protected at least by basic insulation before installation or assembly:
- built-in appliances N/A
- fixed appliances N/A
- appliances delivered in separate units N/A
TRF No. IEC60335_2_15I
Page 12 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
8.2 Class II appliances and constructions constructed Class II construction P
so that there is adequate protection against
accidental contact with basic insulation and metal
parts separated from live parts by basic insulation
only
Only possible to touch parts separated from live P
parts by double or reinforced insulation
10 POWER INPUT AND CURRENT
10.1 Power input at normal operating temperature, rated (see appended table) P
voltage and normal operation not deviating from
rated power input by more than shown in table 1 ..:
Test carried out at upper and lower limits of the N/A
ranges for appliances with one or more rated
voltage ranges, unless
the rated power input is related to the arithmetic N/A
mean value
10.2 Current at normal operating temperature, rated N/A
voltage and normal operation not deviating from
rated current by more than shown in table 2 .........:
Test carried out at upper and lower limits of the N/A
ranges for appliances with one or more rated
voltage ranges, unless
the rated current is related to the arithmetic mean N/A
value of the range
11 HEATING
11.1 No excessive temperatures in normal use P
11.2 The appliance is held, placed or fixed in position as P
described ...............................................................:
Portable appliances are tested away from the walls P
of the test corner (IEC 60335-2-15:2002)
11.3 Temperature rises, other than of windings, P
determined by thermocouples
Temperature rises of windings determined by N/A
resistance method, unless
the windings are non-uniform or it is difficult to Transformer winding P
make the necessary connections
11.4 Heating appliances operated under normal PE-12: 1,15x900 W=1035 W, P
operation at 1.15 times rated power input (W) .....: 239,6 V for 220 V sample and
139,3 V for 127 V sample;
PE-09: 1,15x800 W=920 W,
231,6 V for 220 V sample and
136,5 V for 127 V sample
TRF No. IEC60335_2_15I
Page 13 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
If the temperature rise limits are exceeded in N/A
appliances incorporating motors, transformers or
electronic circuits and if the power input is lower
than the rated power input, the test is repeated with
the appliance supplied at 1,06 times rated voltage
(IEC 60335-2-15:2002)
11.5 Motor-operated appliances operated under normal N/A
operation at most unfavourable voltage between
0.94 and 1.06 times rated voltage (V) ...................:
11.6 Combined appliances operated under normal N/A
operation at most unfavourable voltage between
0.94 and 1.06 times rated voltage (V) ...................:
Combined appliances are tested as heating N/A
appliances (IEC 60335-2-15:2002)
11.7 Appliances are operated for the duration specified 11.7.105 P
in 11.7.101 to 11.7.105 (IEC 60335-2-15:2002)
11.7.101 For kettles with temperature limiter : test terminated N/A
after second operation of temperature limiter
(IEC 60335-2-15:2002)
For kettles with thermostat : test terminated 15 min N/A
after the water has attained 95 °C and 5 min after
for others kettles
11.7.102 For cooking pans, egg boilers, feeding-bottle heaters, glue pots, livestock feed
boilers, milk heaters, sterilizers, wash boilers and for appliances that boil water other
than kettles, the fest is terminated: (IEC 60335-2-15/A1:2005)
- appliances without a thermal control, 15 min after N/A
the water in the container has attained a
temperature of 95 °C or the maximum temperature
it can attain if this is lower
- portable appliances : 15 min after the thermal N/A
control has operated for the first time
- fixed appliances : 30 min after the thermal control N/A
has operated for the first time
- appliances with acoustic signal : 1 min after signal N/A
For appliances having heated surface for keeping N/A
the liquid warm : also until steady conditions with
and without the container
11.7.103 Slow cookers, rice cookers, steam cookers and N/A
yoghurt makers are operated until steady conditions
are established (IEC 60335-2-15:2002)
Slow cookers are prewarmed in the dry state if this N/A
instruction is given
11.7.104 Espresso coffee-makers are operated in N/A
accordance with the instructions for use
(IEC 60335-2-15:2002)
TRF No. IEC60335_2_15I
Page 14 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Automatic espresso coffee makers and espresso N/A
coffee makers, the brewing period is the time
necessary to produce the maximum quantity of
coffee allowed by the timer or by the capacity of the
coffee pot (IEC 60335-2-15/A2:2008)
Manual espresso coffee makers, maximum quantity N/A
of coffee to be produced specified in the
instructions, or (IEC 60335-2-15/A2:2008)
the brewing period is the time necessary to produce N/A
100 ml of coffee for each cycle
(IEC 60335-2-15/A2:2008)
Espresso coffee-makers having an outlet for N/A
supplying steam or hot water, the brewing period is
immediately followed by a period during which the
steam or water is supplied for the time stated in the
instructions, or (IEC 60335-2-15/A2:2008)
- espresso coffee makers having an outlet for N/A
supplying steam, 1 min. (IEC 60335-2-15/A2:2008)
- espresso coffee makers having an outlet for N/A
supplying water, the time necessary to produce 100
ml of water (IEC 60335-2-15/A2:2008)
11.7.105 Pressure cookers operated 15 min after attaining Maximum cooking pressure: P
the maximum cooking pressure 70 kPa
(IEC 60335-2-15:2002)
11.8 Temperature rises monitored continuously and not (see appended tables) P
exceeding the values in table 3 :
When an appliance connector incorporates a N/A
thermostat, the temperature rise limit for the pins of
the inlet does not apply (IEC 60335-2-15:2002)
The temperature rise limits of motors, transformers, N/A
components of electronic circuit and parts directly
influenced by them may be exceeded when the
appliance is operated at 1,15 times rated power
input (IEC 60335-2-15:2002)
If the temperature rise of a motor winding exceeds N/A
the value of table 3, or
if there is doubt with regard to classification of N/A
insulation,
tests of Annex C are carried out N/A
Sealing compound does not flow out N/A
Protective devices do not operate, except P
components in protective electronic circuits tested No protective electronic circuits N/A
for the number of cycles specified in 24.1.4
TRF No. IEC60335_2_15I
Page 15 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING
TEMPERATURE
13.1 Leakage current not excessive and electric strength P
adequate
Heating appliances operated at 1.15 times the rated PE-12: 1,15x900 W=1035 W P
power input (W): PE-09: 1,15x800 W=920 W
Motor-operated appliances and combined N/A
appliances supplied at 1.06 times the rated voltage
(V):
Protective impedance and radio interference filters N/A
disconnected before carrying out the tests
13.2 For class 0, class II and class III appliances, N/A
leakage current measured by means of the circuit
described in figure 4 of IEC 60990
For other appliances, a low impedance ammeter Class I appliance P
may be used
Leakage current measurements : (see appended table) P
13.3 The appliance is disconnected from the supply P
Electric strength tests according to table 4: (see appended table) P
No breakdown during the tests P
14 TRANSIENT OVERVOLTAGES
Appliances withstand the transient over-voltages to N/A
which they may be subjected
Clearances having a value less than specified in N/A
table 16 subjected to an impulse voltage test, the
test voltage specified in table 6:
No flashover during the test, unless N/A
of functional insulation if the appliance complies N/A
with clause 19 with the clearance short-circuited
15 MOISTURE RESISTANCE
15.1 Enclosure provides the degree of moisture P
protection according to classification of the
appliance
Compliance checked as specified in 15.1.1, taking N/A
into account 15.1.2, followed by the electric strength
test of 16.3
No trace of water on insulation which can result in a N/A
reduction of clearances or creepage distances
below values specified in clause 29
15.1.1 Appliances, other than IPX0, subjected to tests as N/A
specified in IEC 60529:
TRF No. IEC60335_2_15I
Page 16 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Water valves containing live parts in external hoses N/A
for connection of an appliance to the water mains
tested as specified for IPX7 appliances
15.1.2 Hand-held appliance turned continuously through N/A
the most unfavourable positions during the test
Built-in appliances installed according to the N/A
instructions
Appliances placed or used on the floor or table N/A
placed on a horizontal unperforated support
Appliances normally fixed to a wall and appliances N/A
with pins for insertion into socket-outlets are
mounted on a wooden board
For IPX3 appliances, the base of wall mounted N/A
appliances is placed at the same level as the pivot
axis of the oscillating tube
For IPX4 appliances, the horizontal centre line of N/A
the appliance is aligned with the pivot axis of the
oscillating tube, and
for appliances normally used on the floor or table, N/A
the movement is limited to two times 90° for a
period of 5 min, the support being placed at the
level of the pivot axis of the oscillating tube
Wall-mounted appliances, take into account the N/A
distance to the floor stated in the instructions
Appliances normally fixed to a ceiling are mounted N/A
underneath a horizontal unperforated support, the
pivot axis of the oscillating tube located at the level
of the underside of the support, and
for IPX4 appliances, the movement of the tube is N/A
limited to two times 90° from the vertical for a period
of 5 min
Appliances with type X attachment fitted with a N/A
flexible cord as described
Detachable parts subjected to the relevant N/A
treatment with the main part
However, if a part has to be removed for user N/A
maintenance and a tool is needed, this part is not
removed
15.2 Spillage of liquid does not affect the electrical P
insulation
Appliances with type X attachment fitted with a N/A
flexible cord as described
TRF No. IEC60335_2_15I
Page 17 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Appliances incorporating an appliance inlet tested N/A
with or without an connector, whichever is most
unfavourable
The test is only carried out with the appliance P
connector in position (IEC 60335-2-15:2002)
For cordless kettles, the test with the kettle on N/A
horizontal plane carried out with the kettle both on
and off its stand (IEC 60335-2-15:2002)
For rice cookers, the test carried out with the rice P
container in place (IEC 60335-2-15/A2:2008)
In case of doubt, spillage tests carried out with the P
appliance deviating from the normal position by an
angle not exceeding 5° (IEC 60335-2-15:2002)
Detachable parts are removed P
Overfilling test with additional amount of 0,75 l P
water, over a period of 1 min (l):
The appliance withstands the electric strength test P
of 16.3
No trace of water on insulation that can result in a P
reduction of clearances or creepage distances
below values specified in clause 29
Kettles that can be filled through the spout: N/A
additional overfilling test in conditions as specified
(IEC 60335-2-15:2002, IEC 60335-2-15/A1:2005)
For cordless kettles, the additional test carried out N/A
only with the cordless kettle off its stand, the kettle
being replaced on its stand in order to carry out the
electric strength test of 16.3 (IEC 60335-2-15:2002)
Steam sterilizers : particular overfilling test in N/A
conditions as specified (IEC 60335-2-15/A1:2005)
Espresso coffee makers provided with a removable N/A
coffee pot: particular overfilling test in conditions as
specified (IEC 60335-2-15/A2:2008)
15.3 Appliances proof against humid conditions P
Checked by test Cab: Damp heat steady state in P
IEC 60068-2-78
Detachable parts removed and subjected, if P
necessary, to the humidity test with the main part
Humidity test for 48 h in a humidity cabinet 25 °C, 93 % R.H. P
Reassembly of those parts that may have been P
removed
The appliance withstands the tests of clause 16 P
TRF No. IEC60335_2_15I
Page 18 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
15.101 Appliances to be partially or completely immersed in Not for such use N/A
water for cleaning sufficiently protected against
effects of immersion (IEC 60335-2-15:2002)
Compliance is checked by the tests as specified, N/A
which are carried out on three additional appliances
(IEC 60335-2-15:2002)
No trace of water on insulation which can result in N/A
reduction of creepage distances and clearance
below values specified in 29
15.102 Connecting device of stands for cordless kettles not N/A
affected by water : particular electric strength test
in conditions as specified (IEC 60335-2-15:2002)
Compliance is checked by the test in conditions as N/A
specified (IEC 60335-2-15/A1:2005)
Stand withstanding the test of 16.3 with voltage N/A
reduced to 2500 V for reinforced insulation
(IEC 60335-2-15:2002)
15.103 Interior of rice cookers not affected by water P
(IEC 60335-2-15/A2:2008)
Compliance is checked by the test as specified P
Rice cookers withstanding the electric strength test P
of 16.3
16 LEAKAGE CURRENT AND ELECTRIC STRENGTH
16.1 Leakage current not excessive and electric strength P
adequate
Protective impedance disconnected from live parts N/A
before carrying out the tests
Tests carried out at room temperature and not P
connected to the supply
16.2 Single-phase appliances: test voltage 1.06 times 1,06x127=233,2 V; P
rated voltage (V): 1,06x127=134,6 V
Three-phase appliances: test voltage 1.06 times N/A
rated voltage divided by √3 (V):
Leakage current measurements : (see appended table) P
Limit values doubled if:
- all controls have an off position in all poles, or N/A
- the appliance has no control other than a thermal N/A
cut-out, or
- all thermostats, temperature limiters and energy N/A
regulators do not have an off position, or
- the appliance has radio interference filters N/A
TRF No. IEC60335_2_15I
Page 19 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
With the radio interference filters disconnected, the N/A
leakage current do not exceed limits specified .....:
16.3 Electric strength tests according to table 7............: (see appended table) P
Test voltage applied between the supply cord and (see appended table) P
inlet bushing and cord guard and cord anchorage
as specified ...........................................................:
No breakdown during the tests P
17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS
No excessive temperatures in transformer or Tested with appliance P
associated circuits in event of short-circuits likely to
occur in normal use ...............................................:
Appliance supplied with 1.06 or 0.94 times rated (see appended tables) P
voltage under the most unfavourable short-circuit or
overload likely to occur in normal use (V) .............:
Basic insulation is not short-circuited N/A
Temperature rise of insulation of the conductors of N/A
safety extra-low voltage circuits not exceeding the
relevant value specified in table 3 by more than
15 K
Temperature of the winding not exceeding the value (see appended table) P
specified in table 8
However, limits do not apply to fail-safe N/A
transformers complying with sub-clause 15.5 of IEC
61558-1
19 ABNORMAL OPERATION
19.1 The risk of fire, mechanical damage or electric P
shock under abnormal or careless operation
obviated
Electronic circuits so designed and applied that a P
fault will not render the appliance unsafe .............:
Appliances incorporating heating elements P
subjected to the tests of 19.2 and 19.3, and
if the appliance also has a control that limit the P
temperature during clause 11 it is subjected to the
test of 19.4, and
if applicable, to the test of 19.5 P
Appliances incorporating PTC heating elements are N/A
also subjected to the test of 19.6
Appliances incorporating motors subjected to the N/A
tests of 19.7 to 19.10, as applicable
TRF No. IEC60335_2_15I
Page 20 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Appliances incorporating electronic circuits P
subjected to the tests of 19.11 and 19.12, as
applicable
Appliances incorporating contactors or relays N/A
subjected to the test of 19.14, being carried out
before the tests of 19.11
Appliances incorporating voltage selector switches N/A
subjected to the test of 19.15
Unless otherwise specified, the tests are continued P
until a non-self-resetting thermal cut-out operates,
or
until steady conditions are established P
If a heating element or intentionally weak part N/A
becomes open-circuited, the relevant test is
repeated on a second sample
Kettles are not subjected to the test of 19.2 N/A
(IEC 60335-2-15:2002)
Kettles also subjected to the test of 19.101, unless N/A
the appliance incorporates a non-self-resetting
thermal cut-out, in order to comply with 19.4
(IEC 60335-2-15:2002)
Kettles for which compliance with 19.101 relies on N/A
the operation of a non-self-resetting thermal cut-out
are subjected to the test of 19.102
(IEC 60335-2-15:2002)
19.2 Test of appliances with heating elements with PE-12: 0,85x900=765 W, P
restricted heat dissipation; test voltage (V), power 205,6 V for 220 V sample,
input of 0.85 times rated power input (W) .............: 120,3 for 127 V sample;
PE-09: 0,85x800=680 W,
220,0 for 220 V sample, 117,8
for 127 V sample
(see appended table)
Appliances are placed as near as possible to the P
walls of the test corner (IEC 60335-2-15:2002)
They are tested empty with lids open or closed Tested empty with lid closed P
whichever is the more unfavourable
(IEC 60335-2-15:2002)
Induction rice cookers operating under the N/A
conditions of clause 11 with the rice container
empty (IEC 60335-2-15/A2:2008)
TRF No. IEC60335_2_15I
Page 21 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
19.3 Test of 19.2 repeated; test voltage (V), power input PE-12: 1,24x900=1116 W, P
of 1.24 times rated power input (W) ......................: 247,7 V for 220 V sample,
144,3 for 127 V sample;
PE-09: 1,24x800=992 W,
240,3 for 220 V sample, 142,0
for 127 V sample
(see appended table)
Kettles are operated empty at 1.15 times rated N/A
power input (IEC 60335-2-15:2002)
The test is carried out with the kettle filled with N/A
sufficient water to cover the heating element or if
the heating element is not positioned inside the
container, to a depth of 10 mm :
(IEC 60335-2-15:2002)
19.4 Test conditions as in clause 11, any control limiting (see appended table) P
the temperature during tests of clause 11
short-circuited
Pressure regulators of pressure cookers are P
rendered inoperative together with each protective
device in turn (IEC 60335-2-15:2002)
19.5 Test of 19.4 repeated on Class 0I and I appliances Pressure control and thermal P
with tubular sheathed or embedded heating link were positioned on
elements. No short-circuiting, but one end of the different poles of heating
element connected to the sheath element. Test results were
covered by clause 11 and 19.4
The test repeated with reversed polarity and the P
other end of the heating element connected to the
sheath
The test is not carried out on appliances intended to N/A
be permanently connected to fixed wiring and on
appliances where an all-pole disconnection occurs
during the test of 19.4
19.6 Appliances with PTC heating elements tested at N/A
rated voltage, establishing steady conditions
The working voltage of the PTC heating element is N/A
increased by 5% and the appliance is operated until
steady conditions are re-established. The voltage is
then increased in similar steps until 1.5 times
working voltage or until the PTC heating element
ruptures (V) ...........................................................:
19.7 Stalling test by locking the rotor if the locked rotor N/A
torque is smaller than the full load torque, or
locking moving parts of other appliances N/A
Locked rotor, capacitors open-circuited one at a N/A
time
TRF No. IEC60335_2_15I
Page 22 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Test repeated with capacitors short-circuited one at N/A
a time, unless
capacitor is of class P2 of IEC 60252-1 N/A
Appliances with timer or programmer supplied with N/A
rated voltage for each of the tests, for a period
equal to the maximum period allowed ...................:
Other appliances supplied with rated voltage for a N/A
period as specified ................................................:
Espresso coffee-makers incorporating a pump are N/A
operated for a period of 5 min
(IEC 60335-2-15:2002)
Winding temperatures not exceeding values N/A
specified in table 8 .................................................:
19.8 Multi-phase motors operated at rated voltage with N/A
one phase disconnected
19.9 Running overload test on appliances incorporating N/A
motors intended to be remotely or automatically
controlled or liable to be operated continuously
Motor-operated and combined appliances for which N/A
30.2.3 is applicable and that use overload protective
devices relying on electronic circuits to protect the
motor windings, are also subjected to the test
Winding temperatures not exceeding values as N/A
specified ................................................................:
19.10 Series motor operated at 1.3 times rated voltage for N/A
1 min (V) ................................................................:
During the test, parts not being ejected from the N/A
appliance
19.11 Electronic circuits, compliance checked by P
evaluation of the fault conditions specified in
19.11.2 for all circuits or parts of circuits, unless
they comply with the conditions specified in 19.11.1 N/A
Appliances incorporating an electronic circuit that P
relies upon a programmable component to function
correctly, subjected to the test of [Link], unless
restarting does not result in a hazard N/A
Appliances having a device with an off position P
obtained by electronic disconnection, or a device
placing the appliance in a stand-by mode, subjected
to the tests of 19.11.4
If the safety of the appliance under any of the fault P
conditions depends on the operation of a miniature
fuse-link complying with IEC 60127, the test of
19.12 is carried out
TRF No. IEC60335_2_15I
Page 23 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
During and after each test the following is checked:
- the temperature of the windings do not exceed the P
values specified in table 8
- the appliance complies with the conditions P
specified in 19.13
- any current flowing through protective impedance N/A
not exceeding the limits specified in 8.1.4
If a conductor of a printed board becomes open-circuited, the appliance is
considered to have withstood the particular test, provided both of the following
conditions are met:
- the base material of the printed circuit board N/A
withstands the test of Annex E
- any loosened conductor does not reduce N/A
clearance or creepage distances between live parts
and accessible metal parts below the values
specified in clause 29
19.11.1 Fault conditions a) to g) in 19.11.2 are not applied to circuits or parts of circuits
meeting both of the following conditions:
- the electronic circuit is a low-power circuit, that is, N/A
the maximum power at low-power points does not
exceed 15 W according to the tests specified
- the protection against electric shock, fire hazard, N/A
mechanical hazard or dangerous malfunction of
other parts of the appliance does not rely on the
correct functioning of the electronic circuit
19.11.2 Fault conditions applied one at a time, the appliance operating under conditions
specified in clause 11, but supplied at rated voltage, duration of the tests as
specified:
a) short circuit of functional insulation if clearances N/A
or creepage distances are less than the values
specified in clause 29
b) open circuit at the terminals of any component D1, D2, D3, D4, D5, NTC on P
main PCB and D1 on control
panel PCB: no hazard
c) short circuit of capacitors, unless E1, E2, C1, C2 on main PCB, P
EC1 on control panel PCB: no
hazard
they comply with IEC 60384-14 X2 capacitor on Main PCB P
d) short circuit of any two terminals of an electronic D1, D2, D3, D4, D5, NTC, P
component, other than integrated circuits relay, Q1, Q2 on main PCB
and D1 on control panel PCB:
no hazard;
Varistor on main PCB: fuse
link operated, no hazard.
TRF No. IEC60335_2_15I
Page 24 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
This fault condition is not applied between the two N/A
circuits of an optocoupler
e) failure of triacs in the diode mode N/A
f) failure of microprocessors and integrated circuits IC1 on main PCB and IC1, IC2 P
on control panel PCB: no
hazard
g) failure of an electronic power switching device N/A
Each low power circuit is short-circuited by N/A
connecting the low-power point to the pole of the
supply source from which the measurements were
made
19.11.3 If the appliance incorporates a protective electronic N/A
circuit which operates to ensure compliance with
clause 19, the relevant test is repeated with a single
fault simulated, as indicated in a) to g) of 19.11.2
19.11.4 Appliances having a device with an off position N/A
obtained by electronic disconnection, or
a device that can be placed in the stand-by mode, P
subjected to the tests of [Link] to [Link], the P
device being set in the off position or in the stand-by
mode
Appliances incorporating a protective electronic N/A
circuit subjected to the tests of [Link] to
[Link], the tests being carried out after the
protective electronic circuit has operated, except
that
appliances operated for 30 s or 5 min during the N/A
test of 19.7 are not subjected to the tests for
electromagnetic phenomena.
Surge protective devices disconnected, unless N/A
They incorporate spark gaps N/A
[Link] The appliance is subjected to electrostatic P
discharges in accordance with IEC 61000-4-2, test
level 4
[Link] The appliance is subjected to radiated fields in P
accordance with IEC 61000-4-3, test level 3
[Link] The appliance is subjected to fast transient bursts in P
accordance with IEC 61000-4-4, test level 3 or 4 as
specified
[Link] The power supply terminals of the appliance P
subjected to voltage surges in accordance with IEC
61000-4-5, test level 3 or 4 as specified
Earthed heating elements in class I appliances P
disconnected
TRF No. IEC60335_2_15I
Page 25 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
[Link] The appliance is subjected to injected currents in P
accordance with IEC 61000-4-6, test level 3
[Link] Appliances having a rated current not exceeding 16 P
A are subjected to the Class 3 voltage dips and
interruptions in accordance with IEC 61000-4-11
Appliances having a rated current exceeding 16 A N/A
are subjected to the Class 3 voltage dips and
interruptions in accordance with IEC 61000-4-34
[Link] The appliance is subjected to mains signals in N/A
accordance with IEC 61000-4-13, test level class 2
[Link] The appliance is supplied at rated voltage and P
operated under normal operation. After 60s the
power supply is reduced to a level such that the
appliance ceases to respond or parts controlled by
the programmable component cease to operate
The appliance continues to operate normally, or P
requires a manual operation to restart N/A
19.12 If the safety of the appliance for any of the fault Rated current of fuse link: 10 P
conditions specified in 19.11.2 depends on the A, measured current: 30 A
operation of a miniature fuse-link complying with
IEC 60127, the test is repeated, measuring the
current flowing through the fuse-link; measured
current (A); rated current of the fuse-link (A):
19.13 During the tests the appliance does not emit flames, P
molten metal, poisonous or ignitable gas in
hazardous amounts
Temperature rises not exceeding the values shown (see appended table) P
in table 9:
Compliance with clause 8 not impaired P
If the appliance can still be operated it complies with N/A
20.2
Insulation, other than of class III appliances or class III constructions that do not
contain live parts, withstands the electric strength test of 16.3, the test voltage as
specified in table 4:
- basic insulation (V): 1000 V P
- supplementary insulation (V): 1750 V / 1250 V P
- reinforced insulation (V): 3000 V / 2500 V P
After operation or interruption of a control, P
clearances and creepage distances across the
functional insulation withstand the electric strength
test of 16.3, the test voltage being twice the
working voltage
The appliance does not undergo a dangerous P
malfunction, and
TRF No. IEC60335_2_15I
Page 26 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
no failure of protective electronic circuits, if the N/A
appliance is still operable
Appliances tested with an electronic switch in the off position, or in the stand-by
mode:
- do not become operational, or P
- if they become operational, do not result in a N/A
dangerous malfunction during or after the tests of
19.11.4
If the appliance contains lids or doors that are controlled by one or more interlocks,
one of the interlocks may be released provided that:
- the lid or door does not move automatically to an N/A
open position when the interlock is released, and
- the appliance does not start after the cycle in N/A
which the interlock was released
During the test of 19.4, pressure relief devices of Max. pressure: 170 kPa P
pressure cookers operate before pressure has
reached 350 kPa (IEC 60335-2-15:2002)
Temperature rise of windings of induction rice N/A
cookers not exceeding the values specified in 19.7
(IEC 60335-2-15/A2:2008)
Induction rice cookers: the electric strength test is N/A
carried out immediately after switching off the
appliance (IEC 60335-2-15/A2:2008)
19.101 Kettles operated empty at 0,85 times or 1,15 times N/A
rated power input, whichever is more unfavourable,
thermal cut-out that operates during the test of 19.4
short circuited (IEC 60335-2-15:2002)
During the test, any flames keep within the N/A
enclosure of the kettle and supporting surface does
not ignite (IEC 60335-2-15:2002)
After the test, live parts not be accessible N/A
(IEC 60335-2-15:2002)
19.102 Kettles incorporating two self-resetting thermal cut- N/A
outs operated with one of the thermal cut-out short
circuited, empty at 0.85 or 1.15 times rated power
input, whichever is most unfavourable
(IEC 60335-2-15:2002)
Within 2 s of the thermal cut-out operating, the N/A
kettle is filled with water having a temperature of
15 °C ± 5 °C. After 1 min, the kettle is emptied
(IEC 60335-2-15:2002)
The test is carried out 100 times N/A
(IEC 60335-2-15:2002)
TRF No. IEC60335_2_15I
Page 27 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
19.103 Appliances with detachable liquid containers : N/A
automatic transfer of liquid from one container to
another is liable and safe (IEC 60335-2-15:2002)
Compliance is checked by the test as specified N/A
(IEC 60335-2-15:2002)
After the test, the appliance withstands the tests of N/A
16.3 and (IEC 60335-2-15:2002)
no trace of water on insulation which can result in N/A
reduction of creepage distances and clearances
below values specified in clause 29
(IEC 60335-2-15:2002)
19.14 Appliances operated under the conditions of clause N/A
11, any contactor or relay contact operating under
the conditions of clause 11 being short-circuited
For a relay or contactor with more than one contact, N/A
all contacts are short-circuited at the same time
A relay or contactor operating only to ensure the N/A
appliance is energized for normal use is not short-
circuited
If more than one relay or contactor operates in N/A
clause 11, they are short-circuited in turn
19.15 For appliances with a mains voltage selector switch, N/A
the switch is set to the lowest rated voltage position
and the highest value of rated voltage is applied
20 STABILITY AND MECHANICAL HAZARDS
20.1 Appliances having adequate stability P
Tilting test through an angle of 10°, appliance Empty and filled with water P
placed on an inclined plane/horizontal support, not
connected to the supply mains; appliance does not
overturn
Tilting test repeated on appliances with heating P
elements, angle of inclination increased to 15°
Possible heating test in overturned position; N/A
temperature rise does not exceed values shown in
table 9
20.2 Moving parts adequately arranged or enclosed as to No moving parts N/A
provide protection against personal injury
Protective enclosures, guards and similar parts are N/A
non-detachable, and
have adequate mechanical strength N/A
Enclosures that can be opened by overriding an N/A
interlock are considered to be detachable parts
TRF No. IEC60335_2_15I
Page 28 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Self-resetting thermal cut-outs and overcurrent N/A
protective devices not causing a hazard, by
unexpected reclosure
Not possible to touch dangerous moving parts with N/A
the test probe described
21 MECHANICAL STRENGTH
21.1 Appliance has adequate mechanical strength and is P
constructed as to withstand rough handling
Checked by applying 3 blows to every point of the 0,5 J to enclosure and control P
enclosure like to be weak, in accordance with test panel
Ehb of IEC 60068-2-75, spring hammer test, with
an impact energy of 0,5 J
The appliance shows no damage impairing P
compliance with this standard, and
compliance with 8.1, 15.1 and clause 29 not P
impaired
If doubt, supplementary or reinforced insulation N/A
subjected to the electric strength test of 16.3
If necessary, repetition of groups of three blows on N/A
a new sample
See Note 101 (IEC 60335-2-15:2002) N/A
21.2 Accessible parts of solid insulation having strength P
to prevent penetration by sharp implements
Test not applicable if the thickness of Bottom enclosure and control P
supplementary insulation is at least 1 mm and panel: Min. 2,1 mm
reinforced insulation at least 2 mm
The insulation is tested as specified, and does N/A
withstand the electric strength test of 16.3
22 CONSTRUCTION
22.1 Appliance marked with the first numeral of the IP IPX0 N/A
system, relevant requirements of IEC 60529 are
fulfilled
22.2 Stationary appliance: means to ensure all-pole disconnection from the supply being
provided:
- a supply cord fitted with a plug, or N/A
- a switch complying with 24.3, or N/A
- a statement in the instruction sheet that a N/A
disconnection incorporated in the fixed wiring is to
be provided, or
- an appliance inlet N/A
TRF No. IEC60335_2_15I
Page 29 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Singe-pole switches and single-pole protective N/A
devices for the disconnection of heating elements in
single-phase, permanently connected class 01 and
class I appliances, connected to the phase
conductor
22.3 Appliance provided with pins: no undue strain on N/A
socket-outlets
Applied torque not exceeding 0.25 Nm N/A
Pull force of 50N to each pin after the appliance has N/A
being placed in the heating cabinet; when cooled to
room temperature the pins are not displaced by
more than 1mm
Each pin subjected to a torque of 0.4Nm; the pins N/A
are not rotating, unless
rotating does not impair compliance with this N/A
standard
22.4 Appliance for heating liquids and appliance causing P
undue vibration not provided with pins for insertion
into socket-outlets
22.5 No risk of electric shock when touching the pins of X2 capacitor: 0,1 uF P
the plug, for appliances having a capacitor with
rated capacitance exceeding 0,1µF, the appliance
being disconnected from the supply at the instant of
voltage peak
Voltage not exceeding 34 V (V) .............................: 4V P
22.6 Electrical insulation not affected by condensing P
water or leaking liquid
Electrical insulation of Class II appliances not N/A
affected if a hose ruptures or seal leaks
In case of doubt, test as described N/A
22.6 Drain holes shall be at least 5 mm in diameter or Min. diameter: 5,5 mm P
20 mm² in area with a width of at least 3 mm
(IEC 60335-2-15:2002)
22.7 Adequate safeguards against the risk of excessive P
pressure in appliances containing liquid or gases or
having steam-producing devices
Additional test for espresso coffee-maker : (IEC 60335-2-15:2002)
Appliance operated with coffee filter blocked and N/A
any steam valve closed. The maximum pressure
attained is measured, then the appliance is
subjected to twice the measure pressure for 5 min
(IEC 60335-2-15:2002)
No rupture, no abnormal leakage; appliance fit for N/A
further use (IEC 60335-2-15:2002)
TRF No. IEC60335_2_15I
Page 30 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Maximum pressure test with pressure limiting N/A
devices made ineffective (IEC 60335-2-15:2002)
No explosion nor emission of dangerous jets of N/A
steam (IEC 60335-2-15:2002)
Last test repeated in case of rupture of an N/A
intentionally weak part: the appliance shall be
terminated in the same mode
(IEC 60335-2-15:2002)
All pressure regulators and pressure-relief devices 6x70 kPa= 420 kPa P
of pressure cookers are rendered inoperative and
lids closed. Pressure increased to six times the
rated cooking pressure (IEC 60335-2-15:2002)
No rupture of container (IEC 60335-2-15:2002) P
22.8 Electrical connections not subject to pulling during N/A
cleaning of compartments to which access can be
gained without the aid of a tool, and that are likely to
be cleaned in normal use
22.9 Insulation, internal wiring, windings, commutators P
and slip rings not exposed to oil, grease or similar
substances, unless
the substance has adequate insulating properties N/A
22.10 Not possible to reset voltage-maintained non-self- N/A
resetting thermal cut-outs by the operation of an
automatic switching device incorporated within the
appliance, if:
- a non-self-resetting thermal cut-out is required by N/A
the standard, and
- a voltage maintained non-self-resetting thermal N/A
cut-out is used to meet it
Non-self-resetting thermal motor protectors have a N/A
trip-free action, unless
they are voltage maintained N/A
Reset buttons of non-self-resetting controls so N/A
located or protected that accidental resetting is
unlikely
22.11 Reliable fixing of non-detachable parts that provide P
the necessary degree of protection against electric
shock, moisture or contact with moving parts
Obvious locked position of snap-in devices used for N/A
fixing such parts
No deterioration of the fixing properties of snap-in N/A
devices used in parts that are likely to be removed
during installation or servicing
Tests as described Pull=push=50 N to all parts P
TRF No. IEC60335_2_15I
Page 31 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
22.12 Handles, knobs etc. fixed in a reliable manner P
Fixing in wrong position of handles, knobs etc. P
indicating position of switches or similar
components not possible
Axial force 15 N applied to parts, the shape being N/A
so that an axial pull is unlikely to be applied
Axial force 30 N applied to parts, the shape being Handle P
so that an axial pull is likely to be applied
22.13 Unlikely that handles, when gripped as in normal P
use, make the operator’s hand touch parts having a
temperature rise exceeding the value specified for
handles which are held for short periods only
22.14 No ragged or sharp edges creating a hazard for the P
user in normal use, or during user maintenance
No exposed pointed ends of self-tapping screws or P
other fasteners, likely to be touched by the user in
normal use or during user maintenance
22.15 Storage hooks and the like for flexible cords smooth N/A
and well rounded
22.16 Automatic cord reels cause no undue abrasion or N/A
damage to the sheath of the flexible cord, no
breakage of conductors strands and no undue wear
of contacts
Cord reel tested with 6000 operations, as specified N/A
Electric strength test of 16.3, voltage of 1000 V N/A
applied
22.17 Spacers not removable from the outside by hand or N/A
by means of a screwdriver or a spanner
22.18 Current-carrying parts and other metal parts P
resistant to corrosion
22.19 Driving belts not relied upon to provide the required N/A
level of insulation, unless
constructed to prevent inappropriate replacement N/A
22.20 Direct contact between live parts and thermal N/A
insulation effectively prevented, unless
material used is non-corrosive, non-hygroscopic N/A
and non-combustible
22.21 Wood, cotton, silk, ordinary paper and fibrous or P
hygroscopic material not used as insulation, unless
impregnated N/A
This requirement does not apply to magnesium P
oxide and mineral ceramic fibres used for the
electrical insulation of heating elements
TRF No. IEC60335_2_15I
Page 32 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
22.22 Appliances not containing asbestos P
22.23 Oils containing polychlorinated biphenyl (PCB) not P
used
22.24 Bare heating elements, except in class III N/A
appliances or class III constructions that do not
contain live parts, adequately supported
In case of rupture, the heating conductor is unlikely N/A
to come in contact with accessible metal parts
22.25 Sagging heating conductors, except in class III N/A
appliances or class III constructions that do not
contain live parts, cannot come into contact with
accessible metal parts
22.26 For class III constructions the insulation between N/A
parts operating at safety extra-low voltage and other
live parts complies with the requirements for double
or reinforced insulation
22.27 Parts connected by protective impedance separated N/A
by double or reinforced insulation
22.28 Metal parts of Class II appliances conductively N/A
connected to gas pipes or in contact with water,
separated from live parts by double or reinforced
insulation
22.29 Class II appliances permanently connected to fixed N/A
wiring so constructed that the required degree of
access to live parts is maintained after installation
22.30 Parts serving as supplementary or reinforced N/A
insulation fixed so that they cannot be removed
without being seriously damaged, or
so constructed that they cannot be replaced in an P
incorrect position, and so that if they are omitted,
the appliance is rendered inoperable or manifestly
incomplete
22.31 Neither clearances nor creepage distances over P
supplementary and reinforced insulation reduced
below values specified in clause 29 as a result of
wear
Neither clearances nor creepage distances P
between live parts and accessible parts reduced
below values for supplementary insulation if wires,
screws etc. become loose
22.32 Supplementary and reinforced insulation P
constructed or protected against pollution so that
clearances or creepage distances are not reduced
below the values in clause 29
TRF No. IEC60335_2_15I
Page 33 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Supplementary insulation of natural or synthetic N/A
rubber resistant to ageing, or arranged and
dimensioned so that creepage distances are not
reduced below values specified in 29.2
Ceramic material not tightly sintered, similar N/A
materials or beads alone not used as
supplementary or reinforced insulation
Insulating material in which heating conductors are P
embedded is considered to be basic insulation, not
reinforced insulation
Oxygen bomb test at 70 °C for 96 h and 16 h at N/A
room temperature
22.33 Conductive liquids that are or may become P
accessible in normal use and conductive liquids that
are in contact with unearthed accessible metal parts
are not in direct contact with live parts
Electrodes not used for heating liquids N/A
For class II constructions, conductive liquids that N/A
are or may become accessible in normal use and
conductive liquids that are in contact with unearthed
accessible metal parts, not in direct contact with
basic or reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N/A
For class II constructions, conductive liquids which N/A
are in contact with live parts, not in direct contact
with reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N/A
An air layer not used as basic or supplementary N/A
insulation in a double insulation system if likely to be
bridged by leaking liquid
22.34 Shafts of operating knobs, handles, levers etc. not N/A
live, unless
the shaft is not accessible when the part is removed N/A
22.35 For other than class III constructions, handles, P
levers and knobs, held or actuated in normal use,
not becoming live in the event of a failure of basic
insulation
Such parts being of metal, and their shafts or fixings N/A
are likely to become live in the event of a failure of
basic insulation, are either adequately covered by
insulation material or their accessible parts are
separated from their shafts or fixings by
supplementary insulation
TRF No. IEC60335_2_15I
Page 34 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
This requirement does not apply to handles, levers N/A
and knobs on stationary appliances, other than
those of electrical components, provided they are
reliably connected to an earthing terminal or
earthing contact, or separated from live parts by
earthed metal
Insulating material covering metal handles, levers N/A
and knobs withstand the electric strength test of
16.3 for supplementary insulation
22.36 For appliances other than class III, handles N/A
continuously held in the hand in normal use so
constructed that when gripped as in normal use, the
operators hand is not likely to touch metal parts,
unless
they are separated from live parts by double or N/A
reinforced insulation
22.37 Capacitors in Class II appliances not connected to N/A
accessible metal parts and their casings, if of
metal, separated from accessible metal parts by
supplementary insulation, unless
the capacitors comply with 22.42 N/A
22.38 Capacitors not connected between the contacts of a N/A
thermal cut-out
22.39 Lamp holders used only for the connection of lamps N/A
22.40 Motor-operated appliances and combined N/A
appliances intended to be moved while in operation,
or having accessible moving parts, fitted with a
switch to control the motor. The actuating member
of the switch being easily visible and accessible
If the appliance cannot operate continuously, N/A
automatically or remotely without giving rise to a
hazard, appliances for remote operation being fitted
with a switch for stopping the operation. The
actuating member of the switch being easily visible
and accessible
22.41 No components, other than lamps, containing P
mercury
22.42 Protective impedance consisting of at least two N/A
separate components
Values specified in 8.1.4 not exceeded if any one of N/A
the components are short-circuited or open-
circuited
Resistors checked by the test of 14.1 a) in IEC N/A
60065
Capacitors checked by the tests for class Y N/A
capacitors in IEC 60384-14
TRF No. IEC60335_2_15I
Page 35 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
22.43 Appliances adjustable for different voltages, N/A
accidental changing of the setting of the voltage
unlikely to occur
22.44 Appliances not having an enclosure that is shaped P
or decorated like a toy
22.45 When air is used as reinforced insulation, P
clearances not reduced below the values specified
in 29.1.3 due to deformation as a result of an
external force applied to the enclosure
22.46 For programmable protective electronic circuits N/A
used to ensure compliance with the standard, the
software contains measures to control the
fault/error conditions in table R.1
Software that contains measures to control the N/A
fault/error conditions specified in table R.2 is to be
specified in parts 2 for particular constructions or to
address specific hazards
These requirements are not applicable to software N/A
used for functional purpose or compliance with
clause 11
22.47 Appliances connected to the water mains withstand N/A
the water pressure expected in normal use
No leakage from any part, including any inlet water N/A
hose
22.48 Appliances connected to the water mains N/A
constructed to prevent backsiphonage of non-
potable water
22.49 For remote operation, the duration of operation is to N/A
be set before the appliance can be started, unless
the appliance switches off automatically or can N/A
operate continuously without hazard
22.50 Controls incorporated in the appliance take priority N/A
over controls actuated by remote operation
22.51 There is a control on the appliance manually N/A
adjusted to the setting for remote operation before
the appliance can be operated in this mode
There is a visual indication showing that the N/A
appliance is adjusted for remote operation
These requirements not necessary on appliances that can operate as follows,
without giving rise to a hazard:
- continuously, or N/A
- automatically, or N/A
- remotely N/A
TRF No. IEC60335_2_15I
Page 36 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
22.52 Socket-outlets on appliances accessible to the user N/A
in accordance with the socket-outlet system used in
the country in which the appliance is sold
22.101 Kettles constructed so that the lid does not fall off N/A
when water is poured out (IEC 60335-2-15:2002)
Compliance is checked by the test as specified N/A
(IEC 60335-2-15:2002)
Lid not fall off and water only emitted from the spout N/A
(IEC 60335-2-15:2002)
22.102 Kettles so constructed that there are no sudden jets N/A
of steam or hot water likely to expose the user to a
hazard when the appliance is used as in normal use
(IEC 60335-2-15:2002)
Compliance is checked by inspection during the test N/A
of clause 11
22.103 Appliance coupler of cordless kettles constructed to N/A
withstand the stresses occurring during normal use
(IEC 60335-2-15:2002)
Kettle is inserted into and withdrawn from the stand N/A
10 000 times (1,1 times the rated current) (10 times
per min)
The test is continued for a further 10 000 times N/A
without current flowing
The kettle is suitable for further use and compliance N/A
with 8.1, 16.3, 27.5 and clause 29 not be impaired
22.104 Portable appliances in which water boil with a P
container greater than 3 l is filled to its rated
capacity with the lid closed in accordance with
instructions for use (IEC 60335-2-15:2002)
The plane is slowly inclined to an angle of 25 ° ; if Not overturn N/A
the appliance overturns, it is left in this position for
10 s and then returned to its normal position
The rate of discharge of liquid does not exceed 16 N/A
l/min
22.105 Fixed appliances for boiling water constructed so N/A
that the container is always open to the atmosphere
through an aperture of at least 5 mm in diameter or
20 mm² in area with a width of at least 3 mm
(IEC 60335-2-15:2002)
Aperture not likely to be obstructed in normal use N/A
If the appliance has provisions for discharging N/A
steam or water overflowing, the discharge aperture
shall be at the base of the appliance and discharge
vertically downwards
TRF No. IEC60335_2_15I
Page 37 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
22.106 Espresso coffee-maker: not possible to remove the N/A
filter by a simple operation while there is hazardous
pressure within the container
(IEC 60335-2-15:2002)
22.107 Pressure cookers incorporate a non-self-resetting Silicone ring P
pressure or temperature responsive pressure relief
device (IEC 60335-2-15:2002)
22.108 Pressure cooker: not possible to remove the lid P
when the inner pressure is excessive
(IEC 60335-2-15:2002)
Pressure test at 4 kPa and 100 N P
No hazardous displacement of lid at removal P
22.109 Feeding-bottle heater: visible or audible signal to N/A
indicate the end of the heating period
(IEC 60335-2-15:2002)
22.110 Espresso coffee-makers, incorporating a N/A
pressurized reservoir filled by the user constructed
so that there is no spillage of water or sudden jets
of steam or hot water (IEC 60335-2-15/A1:2005)
When removing the filling cap of the pressurized N/A
reservoir, before the cap is removed completely, the
pressure relieves in a controlled manner
Compliance is checked by inspection during the test N/A
of clause 11 and by removing the filling cap at the
end of the test
23 INTERNAL WIRING
23.1 Wireways smooth and free from sharp edges P
Wires protected against contact with burrs, cooling P
fins etc.
Wire holes in metal well-rounded or provided with N/A
bushings
Wiring effectively prevented from coming into No moving parts N/A
contact with moving parts
23.2 Beads etc. on live wires cannot change their N/A
position, and are not resting on sharp edges
Beads inside flexible metal conduits contained N/A
within an insulating sleeve
23.3 Electrical connections and internal conductors N/A
movable relatively to each other not exposed to
undue stress
Flexible metallic tubes not causing damage to N/A
insulation of conductors
Open-coil springs not used N/A
TRF No. IEC60335_2_15I
Page 38 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Adequate insulating lining provided inside a coiled N/A
spring, the turns of which touch one another
No damage after 10 000 flexings for conductors N/A
flexed during normal use, or
100 flexings for conductors flexed during user N/A
maintenance
Electric strength test of 16.3, 1000 V between live N/A
parts and accessible metal parts
Not more than 10% of the strands of any conductor N/A
broken, and
not more than 30% for wiring supplying circuits that N/A
consume no more than 15W
23.4 Bare internal wiring sufficiently rigid and fixed N/A
23.5 The insulation of internal wiring subjected to the P
supply mains voltage withstanding the electrical
stress likely to occur in normal use
Basic insulation electrically equivalent to the basic N/A
insulation of cords complying with IEC 60227 or IEC
60245, or
no breakdown when a voltage of 2000 V is applied P
for 15 min between the conductor and metal foil
wrapped around the insulation
23.6 Sleeving used as supplementary insulation on N/A
internal wiring retained in position by clamping at
both ends, or
be such that it can only be removed by breaking or N/A
cutting
23.7 The colour combination green/yellow only used for P
earthing conductors
23.8 Aluminium wires not used for internal wiring N/A
23.9 Stranded conductors not consolidated by soldering N/A
where they are subjected to contact pressure,
unless
the contact pressure is provided by spring terminals N/A
23.10 The insulation and sheath of internal wiring, N/A
incorporated in external hoses for the connection of
an appliance to the water mains, at least equivalent
to that of light polyvinyl chloride sheathed flexible
cord (60227 IEC 52)
24 COMPONENTS
24.1 Components comply with safety requirements in P
relevant IEC standards
List of components : (see appended table) P
TRF No. IEC60335_2_15I
Page 39 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
If components have not been tested and found to P
comply with relevant IEC standard for the number
of cycles specified, they are tested in accordance
with 24.1.1 to 24.1.9
For components mentioned in 24.1.1 to 24.1.9 no P
additional tests specified in the relevant component
standard are necessary other than those specified
in 24.1.1 to 24.1.9
Components not tested and found to comply with P
relevant IEC standard and components not marked
or not used in accordance with its marking, tested
under the conditions occurring in the appliance
Lampholders and starterholders that have not being N/A
tested and found to comply with the relevant IEC
standard, tested as a part of the appliance and
additionally according to the gauging and
interchangeability requirements of the relevant IEC
standard
No additional tests specified for nationally P
standardized plugs such as those detailed in
IEC/TR 60083 or connectors complying with the
standard sheets of IEC 60320-1 and IEC 60309
24.1.1 Capacitors likely to be permanently subjected to the P
supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14
If the capacitors have to be tested, they are tested N/A
according to Annex F
24.1.2 Safety isolating transformers complying with IEC N/A
61558-2-6
If they have to be tested, they are tested according N/A
to Annex G
24.1.3 Switches complying with IEC 61058-1, the number N/A
of cycles of operation being at least 10 000
If they have to be tested, they are tested according N/A
to Annex H
If the switch operates a relay or contactor, the N/A
complete switching system is subjected to the test
If the switch only operates a motor staring relay N/A
complying with IEC 60730-2-10 with the number of
cycles of a least 10 000 as specified, the complete
switching system need not be tested
Switches incorporated in espresso coffee-makers N/A
for initiating brewing or steaming tested for
10 000 cycles (IEC 60335-2-15:2002)
TRF No. IEC60335_2_15I
Page 40 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
24.1.4 Automatic controls complying with IEC 60730-1 with the relevant part 2. The number
of cycles of operation being at least:
- thermostats: 10 000 N/A
- temperature limiters: 1 000 N/A
- self-resetting thermal cut-outs: 300 N/A
- voltage maintained non-self-resetting 1 000 N/A
thermal cut-outs:
- other non-self-resetting thermal cut-outs: 30 N/A
- timers: 3 000 N/A
- energy regulators: 10 000 N/A
The number of cycles for controls operating during N/A
clause 11 need not be declared, if the appliance
meets the requirements of this standard when they
are short-circuited
Thermal motor protectors are tested in combination N/A
with their motor under the conditions specified in
Annex D
For water valves containing live parts and that are N/A
incorporated in external hoses for connection of an
appliance to the water mains, the degree of
protection declared for subclause 6.5.2 of IEC
60730-2-8 is IPX7
Self-resetting thermal cut-outs required for N/A
compliance with the test of 19.101 are subjected to
3 000 cycles of operation (IEC 60335-2-15:2002)
24.1.5 Appliance couplers complying with IEC 60320-1 P
However, for appliances classified higher than N/A
IPX0, the appliance couplers complying with IEC
60320-2-3
Interconnection couplers complying with IEC 60320- N/A
2-2
Appliance couplers incorporating thermostats, N/A
thermal cut-outs or fuses in the connectors comply
with IEC 60320-1, except that:
(IEC 60335-2-15:2002)
- the earthing contact of connector is allowed to be N/A
accessible, if contact is not likely to be gripped
during insertion or withdrawal of the connector
- the temperature required for the test of clause 18 N/A
is that measured on the pins of the appliance inlet
during test of clause 11 of this standard
- The breaking-capacity test of clause 19 carried out N/A
using the inlet of the appliance
TRF No. IEC60335_2_15I
Page 41 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- the temperature rise of current-carrying parts N/A
specified in clause 21 not determined
24.1.6 Small lamp holders similar to E10 lampholders N/A
complying with IEC 60238, the requirements for
E10 lampholders being applicable
24.1.7 For remote operation of the appliance via a N/A
telecommunication network, the relevant standard
for the telecommunication interface circuitry in the
appliance is IEC 62151
24.1.8 The relevant standard for thermal links is IEC VDE approved P
60691
Thermal links not complying with IEC 60691 are N/A
considered to be an intentionally weak part for the
purposes of Clause 19
24.1.9 Contactors and relays, other than motor starting P
relays, tested as part of the appliance
They are also tested in accordance with Clause 17 N/A
of IEC 60730-1, the number of cycles of operations
in 24.1.4 selected according to the contactor or
relay function in the appliance ...............................:
24.2 Appliances not fitted with:
- switches or automatic controls in flexible cords P
- devices causing the protective device in the fixed P
wiring to operate in the event of a fault in the
appliance
- thermal cut-outs that can be reset by soldering, N/A
unless
the solder has a melding point of at least 230 ˚C N/A
24.3 Switches intended for all-pole disconnection of N/A
stationary appliances are directly connected to the
supply terminals and have a contact separation in
all poles, providing full disconnection under
overvoltage category III conditions
24.4 Plugs and socket-outlets for extra-low voltage N/A
circuits and heating elements, not interchangeable
with plugs and socket-outlets listed in
IEC/TR 60083 or IEC 60906-1 or with connectors
and appliance inlets complying with the standard
sheets of IEC 60320-1
See Note 101 (IEC 60335-2-15:2002) N/A
24.5 Capacitors in auxiliary windings of motors marked N/A
with their rated voltage and capacitance, and used
accordingly
TRF No. IEC60335_2_15I
Page 42 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Voltage across capacitors in series with a motor N/A
winding does not exceed 1,1 times rated voltage,
when the appliance is supplied at 1,1 times rated
voltage under minimum load
24.6 Working voltage of motors connected to the supply N/A
mains and having basic insulation that is
inadequate for the rated voltage of the appliance,
not exceeding 42 V
In addition, the motors comply with the N/A
requirements of Annex I
24.7 Detachable hose-sets for connection of appliances N/A
to the water mains comply with IEC 61770
They are supplied with the appliance N/A
Appliances intended to be permanently connected N/A
to the water mains not connected by a detachable
hose-set
24.8 Motor running capacitors in appliances for which N/A
30.2.3 is applicable and that are permanently
connected in series with a motor winding, not
causing a hazard in event of a failure
One or more of the following conditions are to be met: N/A
- the capacitors are of class P2 according to IEC N/A
60252-1
- the capacitors are housed within a metallic or N/A
ceramic enclosure
- the distance of separation of the outer surface to N/A
adjacent non-metallic parts exceeds 50 mm
- adjacent non-metallic parts within 50 mm N/A
withstand the needle-flame test of Annex E
- adjacent non-metallic parts within 50 mm N/A
classified as at least V-1 according to IEC 60695-
11-10
24.101 Devices incorporated in appliance, other than P
kettles, in order to comply with 19.4 are non-self-
resetting (IEC 60335-2-15:2002)
However, self-resetting thermal cut-outs are N/A
allowed for fixed water boilers, if they have been
tested for 10 000 cycles of operation
Compliance is checked by inspection and during the P
test of 19.4
25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS
25.1 Appliance not intended for permanent connection to fixed wiring, means for
connection to the supply:
TRF No. IEC60335_2_15I
Page 43 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- supply cord fitted with a plug, N/A
- an appliance inlet having at least the same degree P
of protection against moisture as required for the
appliance, or
- pins for insertion into socket-outlets N/A
Appliances incorporating an appliance inlet other N/A
than those standardized in IEC 60320-1 are
supplied with a cord set (IEC 60335-2-15:2002)
25.2 Appliance not provided with more than one means P
of connection to the supply mains
Stationary appliance for multiple supply may be N/A
provided with more than one means of connection,
provided electric strength test of 1250 V for 1 min
between each means of connection causes no
breakdown
25.3 Appliance intended to be permanently connected to fixed wiring provided with one of
the following means for connection to the supply mains:
- a set of terminals allowing the connection of a N/A
flexible cord
- a fitted supply cord N/A
- a set of supply leads accommodated in a suitable N/A
compartment
- a set of terminals for the connection of cables of N/A
fixed wiring, cross-sectional areas specified in 26.6,
and the appliance allows the connection of the
supply conductors after the appliance has been
fixed to its support
- a set of terminals and cable entries, conduit N/A
entries, knock-outs or glands, allowing connection
of appropriate types of cable or conduit, and the
appliance allows the connection of the supply
conductors after the appliance has been fixed to its
support
For a fixed appliance constructed so that parts can N/A
be removed to facilitate easy installation, this
requirement is met if it is possible to connect the
fixed wiring without difficulty after a part of the
appliance has been fixed to its support
25.4 Cable and conduit entries, rated current of N/A
appliance not exceeding 16 A, dimension according
to table 10 (mm) ....................................................:
Introduction of conduit or cable does not reduce N/A
clearances or creepage distances below values
specified in clause 29
25.5 Method for assembling the supply cord to the appliance:
TRF No. IEC60335_2_15I
Page 44 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- type X attachment N/A
- type Y attachment N/A
- type Z attachment, if allowed in relevant part 2 N/A
Type Z attachment is allowed for egg boilers, N/A
feeding bottle heaters, yoghurt makers and stands
of cordless kettles (IEC 60335-2-15:2002)
Type X attachment, other than those with a N/A
specially prepared cord, not used for flat twin tinsel
cords
For multi-phase appliances supplied with a supply N/A
cord and that are intended to be permanently
connected to fixed wiring, the supply cord is
assembled to the appliance by type Y attachment
25.6 Plugs fitted with only one flexible cord P
25.7 Supply cords, other than for class III appliances, being one of the following types:
- rubber sheathed (at least 60245 IEC 53) N/A
- polychloroprene sheathed (at least 60245 IEC 57) N/A
- cross-linked polyvinyl chloride sheathed (at least N/A
60245 IEC 88)
- polyvinyl chloride sheathed. Not used if they are likely to touch metal parts having
a temperature rise exceeding 75 K during the test of clause 11
• light polyvinyl chloride sheathed cord N/A
(60227 IEC 52), for appliances not
exceeding 3 kg
• ordinary polyvinyl chloride sheathed cord H05VV-F P
(60227 IEC 53), for other appliances
- heat resistant polyvinyl chloride sheathed. Not used for type X attachment other
than specially prepared cords
• heat-resistant light polyvinyl chloride N/A
sheathed cord (60227 IEC 56), for
appliances not exceeding 3 kg
• heat-resistant polyvinyl chloride sheathed N/A
cord (60227 IEC 57), for other appliances
Supply cords for class III appliances adequately N/A
insulated
Test with 500 V for 2 min for supply cords of class N/A
III appliances that contain live parts
25.7 Supply cord of livestock feed boilers shall be N/A
polychloroprene sheathed (IEC 60335-2-15:2002)
2
25.8 Nominal cross-sectional area of supply cords not Max. 7,1 A, 3x0,75 mm P
less than table 11; rated current (A); cross-sectional (length≤2 m for 127 V sample)
area (mm²):
TRF No. IEC60335_2_15I
Page 45 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Portable appliances having a rated current of up to N/A
10 A may incorporate a supply cord having a
nominal cross-sectional area of 0,75 mm², if the
length is less than 2 m (IEC 60335-2-15:2002)
25.9 Supply cords not in contact with sharp points or P
edges
25.10 Supply cord of class I appliances have a P
green/yellow core for earthing
25.11 Conductors of supply cords not consolidated by N/A
soldering where they are subject to contact
pressure, unless
the contact pressure is provided by spring terminals N/A
25.12 Insulation of the supply cord not damaged when N/A
moulding the cord to part of the enclosure
25.13 Inlet openings so constructed as to prevent damage N/A
to the supply cord
If the enclosure at the inlet opening is not of N/A
insulating material, a non-detachable lining or
bushing complying with 29.3 for supplementary
insulation provided
If unsheathed supply cord, a similar additional N/A
bushing or lining is required, unless the appliance is
class 0, or N/A
a class III appliance not containing live parts N/A
25.14 Supply cords moved while in operation adequately N/A
protected against excessive flexing
Flexing test, as described:
- applied force (N) ..................................................: N/A
- number of flexings ............................................... : N/A
The test does not result in: N/A
- short-circuit between the conductors, such that the N/A
current exceeds a value of twice the rated current
- breakage of more than 10% of the strands of any N/A
conductor
- separation of the conductor from its terminal N/A
- loosening of any cord guard N/A
- damage to the cord or the cord guard N/A
- broken strands piercing the insulation and N/A
becoming accessible
TRF No. IEC60335_2_15I
Page 46 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
25.15 For appliances with supply cord and appliances to N/A
be permanently connected to fixed wiring by a
flexible cord, conductors of the supply cord relieved
from strain, twisting and abrasion by use of cord
anchorage
The cord cannot be pushed into the appliance to N/A
such an extent that the cord or internal parts of the
appliance can be damaged
Pull and torque test of supply cord, values shown in N/A
table 12: mass (kg); pull (N); torque (not on
automatic cord reel) (Nm) .....................................:
Cord not damaged and max. 2 mm displacement of N/A
the cord
25.16 Cord anchorages for type X attachments constructed and located so that:
- replacement of the cord is easily possible N/A
- it is clear how the relief from strain and the N/A
prevention of twisting are obtained
- they are suitable for different types of supply cord N/A
- cord cannot touch the clamping screws of cord N/A
anchorage if these screws are accessible, unless
they are separated from accessible metal parts by N/A
supplementary insulation
- the cord is not clamped by a metal screw which N/A
bears directly on the cord
- at least one part of the cord anchorage securely N/A
fixed to the appliance, unless
it is part of a specially prepared cord N/A
- screws which have to be operated when replacing N/A
the cord do not fix any other component, unless
the appliance becomes inoperative or incomplete or N/A
the parts cannot be removed without a tool
- if labyrinths can be bypassed the test of 25.15 is N/A
nevertheless withstood
- for class 0, 0I and I appliances they are of N/A
insulating material or are provided with an insulating
lining, unless
failure of the insulation of the cord does not make N/A
accessible metal parts live
- for class II appliances they are of insulating N/A
material, or
if of metal, they are insulated from accessible metal N/A
parts by supplementary insulation
TRF No. IEC60335_2_15I
Page 47 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
After the test of 25.15, under the conditions N/A
specified, the conductors have not moved by more
than 1 mm in the terminals
25.17 Adequate cord anchorages for type Y and Z N/A
attachment, test with the cord supplied with the
appliance
25.18 Cord anchorages only accessible with the aid of a N/A
tool, or
Constructed so that the cord can only be fitted with N/A
the aid of a tool
25.19 Type X attachment, glands not used as cord N/A
anchorage in portable appliances
Tying the cord into a knot or tying the cord with N/A
string not used
25.20 The insulated conductors of the supply cord for N/A
type Y and Z attachment additionally insulated from
accessible metal parts
25.21 Space for supply cord for type X attachment or for connection of fixed wiring
constructed:
- to permit checking of conductors with respect to N/A
correct positioning and connection before fitting any
cover
- so there is no risk of damage to the conductors or N/A
their insulation when fitting the cover
- for portable appliances, so that the uninsulated N/A
end of a conductor, if it becomes free from the
terminal, prevented from contact with accessible
metal parts
2 N test to the conductor for portable appliances; no N/A
contact with accessible metal parts
25.22 Appliance inlets:
- live parts not accessible during insertion or P
removal
Requirement not applicable to appliance inlets P
complying with IEC 60320-1
- connector can be inserted without difficulty P
- the appliance is not supported by the connector P
- not for cold conditions if temp. rise of external N/A
metal parts exceeds 75 K during clause 11, unless
the supply cord is unlikely to touch such metal parts N/A
25.23 Interconnection cords comply with the requirements N/A
for the supply cord, except that:
TRF No. IEC60335_2_15I
Page 48 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- the cross-sectional area of the conductors is N/A
determined on the basis of the maximum current
during clause 11
- the thickness of the insulation may be reduced N/A
If necessary, electric strength test of 16.3 N/A
25.24 Interconnection cords not detachable without the N/A
aid of a tool if compliance with this standard is
impaired when they are disconnected
25.25 Dimensions of pins that are inserted into socket- N/A
outlets compatible with the dimensions of the
relevant socket-outlet.
Dimensions of pins and engagement face in N/A
accordance with the dimensions of the relevant plug
in IEC/TR 60083
25.101 Supply cords of kettles are not longer than N/A
75 cm, unless they are helically coiled
(IEC 60335-2-15:2002)
If a cordless kettle has a cord storage facility, the N/A
length of the cord is measured after storing as
much of the cord as possible
26 TERMINALS FOR EXTERNAL CONDUCTORS
26.1 Appliances provided with terminals or equally P
effective devices for connection of external
conductors
Terminals only accessible after removal of a non- N/A
detachable cover, except
for class III appliances that do not contain live parts N/A
Earthing terminals may be accessible if a tool is N/A
required to make the connections and means are
provided to clamp the wire independently from its
connection
26.2 Appliances with type X attachment and appliances N/A
for the connection of cables to fixed wiring provided
with terminals in which connections are made by
means of screws, nuts or similar devices, unless
the connections are soldered N/A
Screws and nuts not used to fix any other N/A
component, except
internal conductors, if so arranged that they are N/A
unlikely to be displaced when fitting the supply
conductors
If soldered connections used, the conductor so N/A
positioned or fixed that reliance is not placed on
soldering alone, unless
TRF No. IEC60335_2_15I
Page 49 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
barriers provided so that neither clearances nor N/A
creepage distances between live parts and other
metal parts reduced below the values for
supplementary insulation if the conductor becomes
free at the soldered joint
26.3 Terminals for type X attachment and for connection N/A
of cables of fixed wiring so constructed that the
conductor is clamped between metal surfaces with
sufficient contact pressure but without damaging
the conductor
Terminals fixed so that when the clamping means is tightened or loosened:
- the terminal does not become loose N/A
- internal wiring is not subjected to stress N/A
- neither clearances nor creepage distances are N/A
reduced below the values in clause 29
Compliance checked by inspection and by the test N/A
of subclause 9.6 of IEC 60999-1, the torque applied
being equal to two-thirds of the torque specified
(Nm) ......................................................................:
No deep or sharp indentations of the conductors N/A
26.4 Terminals for type X attachment, except those N/A
having a specially prepared cord and those for the
connection of cables of fixed wiring, no special
preparation of conductors such as by soldering, use
of cable lugs, eyelets or similar, and
so constructed or placed that conductors prevented N/A
from slipping out when clamping screws or nuts are
tightened
26.5 Terminals for type X attachment so located or N/A
shielded that if a wire of a stranded conductor
escapes, no risk of accidental connection to other
parts that result in a hazard
Stranded conductor test, 8 mm insulation removed N/A
No contact between live parts and accessible metal N/A
parts and,
for class II constructions, between live parts and N/A
metal parts separated from accessible metal parts
by supplementary insulation only
26.6 Terminals for type X attachment and for connection N/A
of cables of fixed wiring suitable for connection of
conductors with cross-sectional area according to
table 13; rated current (A); nominal cross-sectional
area (mm²).............................................................:
If a specially prepared cord is used, terminals need N/A
only be suitable for that cord
TRF No. IEC60335_2_15I
Page 50 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
26.7 Terminals for type X attachment, except in class III N/A
appliances not containing live parts, accessible after
removal of a cover or part of the enclosure
26.8 Terminals for the connection of fixed wiring, N/A
including the earthing terminal, located close to
each other
26.9 Terminals of the pillar type constructed and located N/A
as specified
26.10 Terminals with screw clamping and screwless N/A
terminals not used for flat twin tinsel cords, unless
conductors ends fitted with means suitable for N/A
screw terminals
Pull test of 5 N to the connection N/A
26.11 For type Y and Z attachment, soldered, welded, N/A
crimped or similar connections may be used
For Class II appliances, the conductor so positioned N/A
or fixed that reliance is not placed on soldering,
welding or crimping alone
If soldering, welding or crimping alone used, N/A
barriers provided so that clearances and creepage
distances between live parts and other metal parts
are not reduced below the values for supplementary
insulation if the conductor becomes free
27 PROVISION FOR EARTHING
27.1 Accessible metal parts of Class 0I and I appliances Class I appliance P
permanently and reliably connected to an earthing
terminal or earthing contact of the appliance inlet
Earthing terminals and earthing contacts not P
connected to the neutral terminal
Class 0, II and III appliances have no provision for N/A
earthing
Safety extra-low voltage circuits not earthed, unless N/A
protective extra-low voltage circuits N/A
27.2 Clamping means of earthing terminals adequately N/A
secured against accidental loosening
Terminals for the connection of external N/A
equipotential bonding conductors allow connection
of conductors of 2.5 to 6 mm², and
do not provide earthing continuity between different N/A
parts of the appliance, and
conductors cannot be loosened without the aid of a N/A
tool
TRF No. IEC60335_2_15I
Page 51 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
27.3 For a detachable part having an earth connection N/A
and being plugged into another part of the
appliance, the earth connection is made before and
separated after current-carrying connections when
removing the part
For appliances with supply cords, current-carrying N/A
conductors become taut before earthing conductor,
if the cord slips out of the cord anchorage
27.4 No risk of corrosion resulting from contact between P
parts of the earthing terminal and the copper of the
earthing conductor or other metal
Parts providing earthing continuity, other than parts P
of a metal frame or enclosure, have adequate
resistance to corrosion
If of steel, these parts provided with an N/A
electroplated coating with a thickness at least 5 µm
Adequate protection against rusting of parts of P
coated or uncoated steel, only intended to provide
or transmit contact pressure
In the body of the earthing terminal is a part of a N/A
frame or enclosure of aluminium or aluminium
alloys, precautions taken to avoid risk of corrosion
27.5 Low resistance of connection between earthing P
terminal and earthed metal parts
This requirement does not apply to connections N/A
providing earthing continuity in the protective extra-
low voltage circuit, provided the clearances of basic
insulation are based on the rated voltage of the
appliance
Resistance not exceeding 0,1 Ω at the specified 0,03 Ω P
low-resistance test (Ω )..........................................:
27.6 The printed conductors of printed circuit boards not N/A
used to provide earthing continuity in hand-held
appliances.
They may be used to provide earthing continuity in N/A
other appliances if at least two tracks are used with
independent soldering points and the appliance
complies with 27.5 for each circuit
28 SCREWS AND CONNECTIONS
28.1 Fixings, electrical connections and connections Screws for fixing enclosure, P
providing earthing continuity withstand mechanical PCB and earthing terminal
stresses
Screws not of soft metal liable to creep, such as P
zinc or aluminium
Diameter of screws of insulating material min. 3 mm N/A
TRF No. IEC60335_2_15I
Page 52 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Screws of insulating material not used for any P
electrical connections or connections providing
earthing continuity
Screws used for electrical connections or P
connections providing earthing continuity screwed
into metal
Screws not of insulating material if their P
replacement by a metal screw can impair
supplementary or reinforced insulation
For type X attachment, screws to be removed for N/A
replacement of supply cord or for user
maintenance, not of insulating material if their
replacement by a metal screw impairs basic
insulation
For screws and nuts; torque-test as specified in (see appended table) P
table 14 ..................................................................:
28.2 Electrical connections and connections providing P
earthing continuity constructed so that contact
pressure is not transmitted through non-ceramic
insulating material liable to shrink or distort, unless
there is resiliency in the metallic parts to N/A
compensate for shrinkage or distortion of the
insulating material
This requirement does not apply to electrical connections in circuits of appliances
for which:
• 30.2.2 is applicable and that carry a current N/A
not exceeding 0,5 A
• 30.2.3 is applicable and that carry a current N/A
not exceeding 0,2 A
28.3 Space-threaded (sheet metal) screws only used for N/A
electrical connections if they clamp the parts
together
Thread-cutting (self-tapping) screws and thread N/A
rolling screws only used for electrical connections if
they generate a full form standard machine screw
thread
Thread-cutting (self-tapping) screws not used if they N/A
are likely to be operated by the user or installer
Thread-cutting, thread rolling and space threaded screws may be used in
connections providing earthing continuity provided it is not necessary to disturb the
connection:
- in normal use, N/A
- during user maintenance, N/A
TRF No. IEC60335_2_15I
Page 53 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- when replacing a supply cord having a type X N/A
attachment, or
- during installation N/A
At least two screws being used for each connection N/A
providing earthing continuity, unless
the screw forms a thread having a length of at least N/A
half the diameter of the screw
28.4 Screws and nuts that make mechanical connection P
secured against loosening if they also make
electrical connections or connections providing
earthing continuity
This requirement does not apply to screws in the N/A
earthing circuit if at least two screws are used, or
if an alternative earthing circuit is provided N/A
Rivets for electrical connections or connections N/A
providing earthing continuity secured against
loosening if the connections are subjected to torsion
29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION
Clearances, creepage distances and solid insulation P
withstand electrical stress
For coatings used on printed circuits boards to N/A
protect the microenvironment (Type 1) or to provide
basic insulation (Type 2), Annex J applies ............:
The microenvironment is pollution degree 1 under N/A
type 1 protection
For type 2 protection, the spacing between the N/A
conductors before the protection is applied is not
less than the values specified in Table 1 of IEC
60664-3
These values apply to functional, basic, N/A
supplementary and reinforced insulation ...............:
29.1 Clearances not less than the values specified in P
table 16, taking into account the rated impulse
voltage for the overvoltage categories of table 15,
unless ....................................................................:
for basic insulation and functional insulation they N/A
comply with the impulse voltage test of clause 14
However, if the distances are affected by wear, N/A
distortion, movement of the parts or during
assembly, the clearances for rated impulse voltages
of 1500V and above are increased by 0,5 mm and
the impulse voltage test is not applicable
Impulse voltage test is not applicable:
TRF No. IEC60335_2_15I
Page 54 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- when the microenvironment is pollution degree 3, P
or
- for basic insulation of class 0 and class 01 N/A
appliances
Appliances are in overvoltage category II P
A force of 2 N is applied to bare conductors, other N/A
than heating elements
A force of 30 N is applied to accessible surfaces P
29.1.1 Clearances of basic insulation withstand the P
overvoltages, taking into account the rated impulse
voltage
The values of table 16 or the impulse voltage test of (see appended table) P
clause 14 are applicable ........................................:
Clearance at the terminals of tubular sheathed At the end terminal of heating P
heating elements may be reduced to 1,0 mm if the element
microenvironment is pollution degree 1
Lacquered conductors of windings considered to be P
bare conductors
29.1.2 Clearances of supplementary insulation not less (see appended table) P
than those specified for basic insulation in table 16:
29.1.3 Clearances of reinforced insulation not less than (see appended table) P
those specified for basic insulation in table 16, using
the next higher step for rated impulse voltage:
For double insulation, with no intermediate P
conductive part between basic and supplementary
insulation, clearances are measured between live
parts and the accessible surface, and the insulation
system is treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ......: (see appended table) P
- table F.7a in IEC 60664-1, frequency not N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N/A
kHz
If values of table 16 are largest, the impulse voltage N/A
test of clause 14 may be applied instead, unless
the microenvironment is pollution degree 3, or P
the distances can be affected by wear, distortion, N/A
movement of the parts or during assembly
However, clearances are not specified if the N/A
appliance complies with clause 19 with the
functional insulation short-circuited
TRF No. IEC60335_2_15I
Page 55 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Lacquered conductors of windings considered to be P
bare conductors
However, clearances at crossover points are not P
measured
Clearance between surfaces of PTC heating N/A
elements may be reduced to 1mm
29.1.5 Appliances having higher working voltages than rated voltage, clearances for basic
insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ......: N/A
- table F.7a in IEC 60664-1, frequency not N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N/A
kHz
If clearances for basic insulation are selected from N/A
Table F.7a of IEC 60664-1 or Clause 4 of IEC
60664-4, the clearances of supplementary
insulation are not less than those specified for basic
insulation
If clearances for basic insulation are selected from N/A
Table F.7a of IEC 60664-1, the clearances of
reinforced insulation dimensioned as specified in
Table F.7a are to withstand 160% of the withstand
voltage required for basic insulation
If clearances for basic insulation are selected from N/A
Clause 4 of IEC 60664-4, the clearances of
reinforced insulation are twice the value required for
basic insulation
If the secondary winding of a step-down transformer N/A
is earthed, or if there is an earthed screen between
the primary and secondary windings, clearances of
basic insulation on the secondary side not less than
those specified in table 16, but using the next lower
step for rated impulse voltage
Circuits supplied with a voltage lower than rated N/A
voltage, clearances of functional insulation are
based on the working voltage used as the rated
voltage in table 15
29.2 Creepage distances not less than those appropriate P
for the working voltage, taking into account the
material group and the pollution degree ................:
Pollution degree 2 applies, unless N/A
- precautions taken to protect the insulation; At the end terminal of heating P
pollution degree 1 element
- insulation subjected to conductive pollution; P
pollution degree 3
TRF No. IEC60335_2_15I
Page 56 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
The microenvironment is pollution degree 3 if the P
insulation can be polluted by condensation from
steam produced during normal use of the appliance
(IEC 60335-2-15:2002)
A force of 2 N is applied to bare conductors, other N/A
than heating elements
A force of 30 N is applied to accessible surfaces P
In a double insulation system, the working voltage P
for both the basic and supplementary insulation is
taken as the working voltage across the complete
double insulation system
29.2.1 Creepage distances of basic insulation not less (see appended table) P
than specified in table 17 .......................................:
However, if the working voltage is periodic and has N/A
a frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 17...................................................:
Except for pollution degree 1, corresponding N/A
creepage distance not less than the minimum
specified for the clearance in table 16, if the
clearance has been checked according to the test
of clause 14 ...........................................................:
29.2.2 Creepage distances of supplementary insulation at (see appended table) P
least those specified for basic insulation in table 17,
or ...........................................................................:
Table 2 of IEC 60664-4, as applicable ..................: N/A
29.2.3 Creepage distances of reinforced insulation at least (see appended table) P
double those specified for basic insulation in table
17, or .....................................................................:
Table 2 of IEC 60664-4, as applicable ..................: N/A
29.2.4 Creepage distances of functional insulation not less (see appended table) P
than specified in table 18 .......................................:
However, if the working voltage is periodic and has N/A
a frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 18...................................................:
Creepage distances may be reduced if the N/A
appliance complies with clause 19 with the
functional insulation short-circuited
29.3 Supplementary and reinforced insulation have P
adequate thickness, or a sufficient number of
layers, to withstand the electrical stresses
Compliance checked:
TRF No. IEC60335_2_15I
Page 57 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
- by measurement, in accordance with 29.3.1, or P
- by an electric strength test in accordance with N/A
29.3.2, or
- by an assessment of the thermal quality of the N/A
material combined with an electric strength test, in
accordance with 29.3.3, and
for accessible parts of reinforced insulation N/A
consisting of a single layer, by measurement in
accordance with 29.3.4, or
- as specified in subclause 6.3 of IEC 60664-4 for N/A
insulation that is subjected to any periodic voltage
having a frequency exceeding 30 kHz
29.3.1 Supplementary insulation have a thickness of at Bottom enclosure and control P
least 1 mm panel: Min. 2,1 mm
Reinforced insulation have a thickness of at least 2 N/A
mm
29.3.2 Each layer of material withstand the electric N/A
strength test of 16.3 for supplementary insulation
Supplementary insulation consist of at least 2 layers N/A
Reinforced insulation consist of at least 3 layers N/A
29.3.3 The insulation is subjected to the dry heat test Bb of N/A
IEC 60068-2-2, followed by
the electric strength test of 16.3 N/A
If the temperature rise during the tests of clause 19 N/A
does not exceed the value specified in table 3, the
test of IEC 60068-2-2 is not carried out
29.3.4 Thickness of accessible parts of reinforced N/A
insulation consisting of a single layer not less than
specified in table 19 ...............................................:
30 RESISTANCE TO HEAT AND FIRE
30.1 External parts of non-metallic material, P
parts supporting live parts, and P
parts of thermoplastic material providing P
supplementary or reinforced insulation
sufficiently resistant to heat P
Ball-pressure test according to IEC 60695-10-2 P
External parts tested at 40 °C plus the maximum N/A
temperature rise determined during the test of
clause 11, or at 75 °C, whichever is the higher;
temperature (°C)....................................................:
TRF No. IEC60335_2_15I
Page 58 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Parts supporting live parts tested at 40°C plus the (see appended table) P
maximum temperature rise determined during the
test of clause 11, or at 125 °C, whichever is the
higher; temperature (°C)........................................:
Parts of thermoplastic material providing (see appended table) P
supplementary or reinforced insulation tested at 25
°C plus the maximum temperature rise determined
during clause 19, if higher; temperature (°C) ........:
For coffee makers, egg boilers, steam cookers and N/A
kettles, the temperature rises occurring during the
tests of 19.4, 19.5 and 19.101 are not taken into
account (IEC 60335-2-15:2002)
30.2 Parts of non-metallic material resistant to ignition P
and spread of fire
This requirement does not apply to:
parts having a mass not exceeding 0,5 g, provided P
the cumulative effect is unlikely to propagate flames
that originate inside the appliance by propagating
flames from one part to another, or
decorative trims, knobs and other parts unlikely to P
be ignited or to propagate flames that originate
inside the appliance
Compliance checked by the test of 30.2.1, and in P
addition:
- for attended appliances, 30.2.2 applies N/A
- for unattended appliances, 30.2.3 applies P
For appliances for remote operation, 30.2.3 applies N/A
For base material of printed circuit boards, 30.2.4 P
applies
For water distillers and appliances intended to P
maintain liquid of food at a particular temperature,
30.2.3 applies (IEC 60335-2-15:2002)
For other appliances, 30.2.2 applies N/A
(IEC 60335-2-15:2002)
30.2.1 Parts of non-metallic material subjected to the glow- (see appended table) P
wire test of IEC 60695-2-11 at 550 °C
However, test not carried out if the material is N/A
classified as having a glow-wire flammability index
according to IEC 60695-2-12 of at least 550 °C, or
the material is classified at least HB40 according to N/A
IEC 60695-11-10
TRF No. IEC60335_2_15I
Page 59 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Parts for which the glow-wire test cannot be carried N/A
out need to meet the requirements in ISO 9772 for
material classified HBF
30.2.2 Appliances operated while attended, parts of non- N/A
metallic material supporting current-carrying
connections, and
parts of non-metallic material within a distance of N/A
3mm of such connections,
subjected to the glow-wire test of IEC 60695-2-11 N/A
The test severity is:
- 750 °C, for connections carrying a current N/A
exceeding 0,5 A during normal operation
- 650 °C, for other connections N/A
Glow-wire applied to an interposed shielding N/A
material, if relevant
The glow-wire test is not carried out on parts of material classified as having a glow-
wire flammability index according to IEC 60695-2-12 of at least:
- 750 °C, for connections carrying a current N/A
exceeding 0,5 A during normal operation
- 650 °C, for other connections N/A
The glow-wire test is also not carried out on small parts. These parts are to:
- comprise material having a glow-wire flammability N/A
index of at least 750 °C, or 650 °C as appropriate,
or
- comply with the needle-flame test of Annex E, or N/A
- comprise material classified as V-0 or V-1 N/A
according to IEC 60695-11-10 ..............................:
Glow-wire test not applicable to conditions as N/A
specified ................................................................:
30.2.3 Appliances operated while unattended, tested as P
specified in [Link] and [Link]
The tests are not applicable to conditions as N/A
specified ................................................................:
[Link] Parts of non-metallic material supporting P
connections carrying a current exceeding 0,2 A
during normal operation, and
parts of non-metallic material, other than small N/A
parts, within a distance of 3 mm,
subjected to the glow-wire test of IEC 60695-2-11 (see appended table) P
with a test severity of 850 °C
TRF No. IEC60335_2_15I
Page 60 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Glow-wire applied to an interposed shielding N/A
material, if relevant
The glow-wire test is not carried out on parts of N/A
material classified as having a glow-wire
flammability index according to IEC 60695-2-12 of
at least 850 °C
[Link] Parts of non-metallic material supporting P
connections, and
parts of non-metallic material within a distance of N/A
3mm,
subjected to glow-wire test of IEC 60695-2-11 P
The test severity is:
- 750 °C, for connections carrying a current (see appended table) P
exceeding 0,2 A during normal operation
- 650 °C, for other connections N/A
Glow-wire applied to an interposed shielding N/A
material, if relevant
However, the glow-wire test of 750 °C or 650 °C as appropriate, is not carried out on
parts of material fulfilling both or either of the following classifications:
- a glow-wire ignition temperature according to IEC N/A
60695-2-13 of at least:
• 775 °C, for connections carrying a current N/A
exceeding 0,2 A during normal operation
• 675 °C, for other connections N/A
- a glow-wire flammability index according to IEC N/A
60695-2-12 of at least:
- 750 °C, for connections carrying a current N/A
exceeding 0,2 A during normal operation
- 650 °C, for other connections N/A
The glow-wire test is also not carried out on small parts. These parts are to:
- comprise material having a glow-wire ignition N/A
temperature of at least 775 °C or 675 °C as
appropriate, or
- comprise material having a glow-wire flammability N/A
index of at least 750 °C or 650 °C as appropriate, or
- comply with the needle-flame test of Annex E, or N/A
- comprise material classified as V-0 or V-1 N/A
according to IEC 60695-11-10
TRF No. IEC60335_2_15I
Page 61 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
The consequential needle-flame test of Annex E applied to non-metallic parts that
encroach within the vertical cylinder placed above the centre of the connection zone
and on top of the non-metallic parts supporting current-carrying connections, and
parts of non-metallic material within a distance of 3 mm of such connections if these
parts are those:
- parts that withstood the glow-wire test of IEC P
60695-2-11 of 750 °C or 650 °C as appropriate, but
produce a flame that persist longer than 2 s, or
- parts that comprised material having a glow-wire N/A
flammability index of at least 750 °C or 650 °C as
appropriate, or
- small parts, that comprised material having a N/A
glow-wire flammability index of at least 750 °C or
650 °C as appropriate, or
- small parts for which the needle-flame test of N/A
Annex E was applied, or
- small parts for which a material classification of V- N/A
0 or V-1 was applied
However, the consequential needle-flame test is not carried out on non-metallic
parts, including small parts, within the cylinder that are:
- parts having a glow-wire ignition temperature of at N/A
least 775 °C or 675 °C as appropriate, or
- parts comprising material classified as V-0 or V-1 N/A
according to IEC 60695-11-10, or
- parts shielded by a flame barrier that meets the N/A
needle-flame test of Annex E or that comprises
material classified as V-0 or V-1 according to IEC
60695-11-10
30.2.4 Base material of printed circuit boards subjected to P
the needle-flame test of Annex E
Test not applicable to conditions as specified .......: N/A
31 RESISTANCE TO RUSTING
Relevant ferrous parts adequately protected against P
rusting
Tests specified in part 2 when necessary N/A
32 RADIATION, TOXICITY AND SIMILAR HAZARDS
Appliance does not emit harmful radiation or P
present a toxic or similar hazard due to their
operation in normal use
Compliance is checked by the limits or tests N/A
specified in part 2, if relevant
A ANNEX A (INFORMATIVE)
ROUTINE TESTS
TRF No. IEC60335_2_15I
Page 62 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
Description of routine tests to be carried out by the P
manufacturer
B ANNEX B (NORMATIVE)
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
Not such appliance N/A
C ANNEX C (NORMATIVE)
AGEING TEST ON MOTORS
No such motor N/A
D ANNEX D (NORMATIVE)
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that N/A
incorporate thermal motor protectors necessary for
compliance with the standard
Test conditions as specified N/A
E ANNEX E (NORMATIVE)
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with IEC 60695-11-5, with the following
modifications:
7 Severities
The duration of application of the test flame is (see appended table) P
30 s ± 1 s
9 Test procedure
9.1 The specimen so arranged that the flame can be P
applied to a vertical or horizontal edge as shown in
the examples of Figure 1
9.2 The first paragraph does not apply P
If possible, the flame is applied at least 10 mm from P
a corner
9.3 The test is carried out on one specimen P
If the specimen does not withstand the test, the test N/A
may be repeated on two additional specimens, both
withstanding the test
11 Evaluation of test results
The duration of burning not exceeding 30 s P
However, for printed circuit boards, the duration of P
burning not exceeding 15 s
F ANNEX F (NORMATIVE)
CAPACITORS
No such capacitor N/A
TRF No. IEC60335_2_15I
Page 63 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
G ANNEX G (NORMATIVE)
SAFETY ISOLATING TRANSFORMERS
No such transformer N/A
H ANNEX H (NORMATIVE)
SWITCHES
No such switches N/A
I ANNEX I (NORMATIVE)
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE
RATED VOLTAGE OF THE APPLIANCE
No such motors N/A
J ANNEX J (NORMATIVE)
COATED PRINTED CIRCUIT BOARDS
No PCB under such consideration N/A
K ANNEX K (NORMATIVE)
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is P
extracted from IEC 60664-1
Overvoltage category is a numeral defining a P
transient overvoltage condition
Equipment of overvoltage category IV is for use at N/A
the origin of the installation
Equipment of overvoltage category III is equipment N/A
in fixed installations and for cases where the
reliability and the availability of the equipment is
subject to special requirements
Equipment of overvoltage category II is energy P
consuming equipment to be supplied from the fixed
installation
If such equipment is subjected to special N/A
requirements with regard to reliability and
availability, overvoltage category III applies
Equipment of overvoltage category I is equipment N/A
for connection to circuits in which measures are
taken to limit transient overvoltages to an
appropriate low level
L ANNEX L (INFORMATIVE)
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES
Information for the determination of clearances and P
creepage distances
M ANNEX M (NORMATIVE)
POLLUTION DEGREE
TRF No. IEC60335_2_15I
Page 64 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
The information on pollution degrees is extracted P
from IEC 60664-1
Pollution
The microenvironment determines the effect of P
pollution on the insulation, taking into account the
macroenvironment
Means may be provided to reduce pollution at the P
insulation by effective enclosures or similar
Minimum clearances specified where pollution may P
be present in the microenvironment
Degrees of pollution in the microenvironment
For evaluating creepage distances, the following degrees of pollution in the
microenvironment are established:
- pollution degree 1: no pollution or only dry, non- At the end terminal of heating P
conductive pollution occurs. The pollution has no element
influence
- pollution degree 2: only non-conductive pollution N/A
occurs, except that occasionally a temporary
conductivity caused by condensation is to be
expected
- pollution degree 3: conductive pollution occurs or P
dry non-conductive pollution occurs that becomes
conductive due to condensation that is to be
expected
- pollution degree 4: the pollution generates N/A
persistent conductivity caused by conductive dust or
by rain or snow
N ANNEX N (NORMATIVE)
PROOF TRACKING TEST
The proof tracking test is carried out in accordance with IEC 60112 with the
following modifications:
7 Test apparatus P
7.3 Test solutions P
Test solution A is used (see appended table) P
10 Determination of proof tracking index (PTI) P
10.1 Procedure P
The proof voltage is 100V, 175V, 400V or 600V ...: 175 V P
The test is carried out on five specimens P
In case of doubt, additional test with proof voltage N/A
reduced by 25V, the number of drops increased to
100
TRF No. IEC60335_2_15I
Page 65 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Clause Requirement - Test Result - Remark Verdict
10.2 Report
The report states if the PTI value was based on a N/A
test using 100 drops with a test voltage of (PTI-25)
V
O ANNEX O (INFORMATIVE)
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of resistance P
to heat and fire
P ANNEX P (INFORMATIVE)
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES
No intended for such use N/A
Q ANNEX Q (INFORMATIVE)
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits P
R ANNEX R (NORMATIVE)
SOFTWARE EVALUATION
No software N/A
TRF No. IEC60335_2_15I
Page 66 of 84 Report No.: NBES140100003101
IEC 60335-2-15
10.1 TABLE: Power input deviation P
Input deviation of/at: P rated (W) P measured (W) dP Required dP Remark
220 V (220 V sample 900 889,0 -1,2 % +5 %/-10 %
of PE-12)
127 V (127 V sample 900 867,9 -3,6 % +5 %/-10 %
of PE-12)
220 V (220 V sample 800 832,4 +4,1 % +5 %/-10 %
of PE-09)
127 V (127 V sample 800 798,2 -0,2 % +5 %/-10 %
of PE-09)
11.8 (1) TABLE: Heating test, thermocouples (220 V sample of PE-12) P
Test voltage (V) ........................................................ : 1,15x900 W=1035 W, 239,6 V
Ambient (°C)............................................................. : T1=22,2 °C, T2=22,4 °C
Thermocouple locations dT (K) Max. dT (K)
Supply cord insulation 14,2 50
Pin of appliance inlet 19,3 45
Internal wiring 37,4 175 (T200-25)
Main PCB 32,6 120 and clause 30.1
Main PCB box 37,3 Clause 30.1
Control panel PCB 28,6 120 and clause 30.1
Pri. winding of transformer 39,2 80 (class 120)
Sec. winding of transformer 33,7 80 (class 120)
Transformer bobbin 35,0 Clause 30.1
Wire connector 32,3 Clause 30.1
Ambient of relay 30,8 60 (T85-25)
X2 capacitor surface 32,5 60 (T85-25)
Varistor surface 30,7 60 (T85-25)
Ambient of thermal link 34,2 Reference
Silicone tube for thermal link 29,2 145
Silicone tube for NTC 93,3 145
Ambient of NTC 93,0 Reference
Ambient of pressure control 44,9 175 (T200-25)
Lid handle 19,6 60
Appliance grip 8,8 60
Relief valve knob 18,4 60
TRF No. IEC60335_2_15I
Page 67 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Control panel buttons 18,2 60
Metal enclosure 19,0 Reference
Control panel 14,4 Clause 30.1
Bottom enclosure 25,9 Clause 30.1
Test corner 17,9 65
11.8 (2) TABLE: Heating test, thermocouples (127 V sample of PE-12) P
Test voltage (V) ........................................................ : 1,15x900 W=1035 W, 139,3 V
Ambient (°C)............................................................. : T1=22,6 °C, T2=22,1 °C
Thermocouple locations dT (K) Max. dT (K)
Supply cord insulation 15,7 50
Pin of appliance inlet 23,5 45
Internal wiring 43,8 175 (T200-25)
Main PCB 39,4 120 and clause 30.1
Main PCB box 36,8 Clause 30.1
Control panel PCB 28,8 120 and clause 30.1
Pri. winding of transformer 36,1 80 (class 120)
Sec. winding of transformer 35,3 80 (class 120)
Transformer bobbin 33,5 Clause 30.1
Wire connector 36,1 Clause 30.1
Ambient of relay 35,3 60 (T85-25)
X2 capacitor surface 33,2 60 (T85-25)
Varistor surface 34,1 60 (T85-25)
Ambient of thermal link 39,1 Reference
Silicone tube for thermal link 31,1 145
Silicone tube for NTC 97,7 145
Ambient of NTC 93,5 Reference
Ambient of pressure control 49,5 175 (T200-25)
Lid handle 19,8 60
Appliance grip 7,9 60
Relief valve knob 17,4 60
Control panel buttons 16,6 60
Metal enclosure 16,6 Reference
Control panel 14,7 Clause 30.1
Bottom enclosure 27,2 Clause 30.1
TRF No. IEC60335_2_15I
Page 68 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Test corner 15,3 65
11.8 (3) TABLE: Heating test, thermocouples (220 V sample of PE-09) P
Test voltage (V) ........................................................ : 1,15x800 W=920 W, 231,6 V
Ambient (°C)............................................................. : T1=20,0 °C, T2=20,3 °C
Thermocouple locations dT (K) Max. dT (K)
Supply cord insulation 14,3 50
Pin of appliance inlet 21,3 45
Internal wiring 47,3 175 (T200-25)
Main PCB 33,2 120 and clause 30.1
Main PCB box 43,0 Clause 30.1
Control panel PCB 36,4 120 and clause 30.1
Pri. winding of transformer 33,4 80 (class 120)
Sec. winding of transformer 32,0 80 (class 120)
Transformer bobbin 31,9 Clause 30.1
Wire connector 37,2 Clause 30.1
Ambient of relay 29,8 60 (T85-25)
X2 capacitor surface 31,5 60 (T85-25)
Varistor surface 31,4 60 (T85-25)
Ambient of thermal link 36,4 Reference
Silicone tube for thermal link 31,8 145
Silicone tube for NTC 100,7 145
Ambient of NTC 97,1 Reference
Ambient of pressure control 52,2 175 (T200-25)
Lid handle 26,9 60
Appliance grip 12,5 60
Relief valve knob 25,4 60
Control panel buttons 17,0 60
Metal enclosure 18,1 Reference
Control panel 13,9 Clause 30.1
Bottom enclosure 24,8 Clause 30.1
Test corner 15,6 65
11.8 (4) TABLE: Heating test, thermocouples (127 V sample of PE-09) P
Test voltage (V) ........................................................ : 1,15x800 W=920 W, 136,5 V
TRF No. IEC60335_2_15I
Page 69 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Ambient (°C)............................................................. : T1=20,9 °C, T2=20,8 °C
Thermocouple locations dT (K) Max. dT (K)
Supply cord insulation 15,6 50
Pin of appliance inlet 22,1 45
Internal wiring 39,6 175 (T200-25)
Main PCB 32,2 120 and clause 30.1
Main PCB box 41,4 Clause 30.1
Control panel PCB 30,6 120 and clause 30.1
Pri. winding of transformer 34,5 80 (class 120)
Sec. winding of transformer 33,5 80 (class 120)
Transformer bobbin 31,8 Clause 30.1
Wire connector 32,0 Clause 30.1
Ambient of relay 30,5 60 (T85-25)
X2 capacitor surface 31,7 60 (T85-25)
Varistor surface 30,4 60 (T85-25)
Ambient of thermal link 36,2 Reference
Silicone tube for thermal link 34,4 145
Silicone tube for NTC 95,9 145
Ambient of NTC 100,9 Reference
Ambient of pressure control 47,8 175 (T200-25)
Lid handle 25,1 60
Appliance grip 12,0 60
Relief valve knob 18,4 60
Control panel buttons 15,5 60
Metal enclosure 20,5 Reference
Control panel 13,5 Clause 30.1
Bottom enclosure 25,6 Clause 30.1
Test corner 16,5 65
13.2 (1) TABLE: Leakage current (220 V sample of PE-12) P
Heating appliances: 1.15 x rated input .................. : 1,15x900 W=1035 W
Motor-operated and combined appliances:
1.06 x rated voltage ................................................ :
Leakage current between I (mA) Max. allowed I (mA)
TRF No. IEC60335_2_15I
Page 70 of 84 Report No.: NBES140100003101
IEC 60335-2-15
L/N and accessible earthed metal parts 0,03 0,75
L/N and accessible plastic parts 0,01 0,35 peak
13.2 (2) TABLE: Leakage current (127 V sample of PE-12) P
Heating appliances: 1.15 x rated input .................. : 1,15x900 W=1035 W
Motor-operated and combined appliances:
1.06 x rated voltage ................................................ :
Leakage current between I (mA) Max. allowed I (mA)
L/N and accessible earthed metal parts 0,03 0,75
L/N and accessible plastic parts 0,01 0,35 peak
13.2 (3) TABLE: Leakage current (220 V sample of PE-09) P
Heating appliances: 1.15 x rated input .................. : 1,15x800 W=920 W
Motor-operated and combined appliances:
1.06 x rated voltage ................................................ :
Leakage current between I (mA) Max. allowed I (mA)
L/N and accessible earthed metal parts 0,03 0,75
L/N and accessible plastic parts 0,01 0,35 peak
13.2 (4) TABLE: Leakage current (127 V sample of PE-09) P
Heating appliances: 1.15 x rated input .................. : 1,15x800 W=920 W
Motor-operated and combined appliances:
1.06 x rated voltage ................................................ :
Leakage current between I (mA) Max. allowed I (mA)
L/N and accessible earthed metal parts 0,03 0,75
L/N and accessible plastic parts 0,01 0,35 peak
13.3 (1) TABLE: Electric strength (220 V sample of PE-12 and PE-09) P
Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
L/N and accessible earthed metal parts 1000 No
Internal wiring and accessible plastic parts 1750 No
L/N and accessible plastic parts 3000 No
13.3 (2) TABLE: Electric strength (127 V sample of PE-12 and PE-09) P
Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
TRF No. IEC60335_2_15I
Page 71 of 84 Report No.: NBES140100003101
IEC 60335-2-15
L/N and accessible earthed metal parts 1000 No
Internal wiring and accessible plastic parts 1250 No
L/N and accessible plastic parts 2500 No
16.2 (1) TABLE: Leakage current (220 V sample of PE-12) P
Single phase appliances: 1.06 x rated voltage ......: 1,06x220=233,2 V
Three phase appliances 1.06 x rated voltage
divided by √3:..........................................................:
Leakage current between I (mA) Max. allowed I (mA)
L/N and accessible earthed metal parts 0,04 0,75
L/N and accessible plastic parts 0,02 0,25
16.2 (2) TABLE: Leakage current (127 V sample of PE-12) P
Single phase appliances: 1.06 x rated voltage ......: 1,06x127=134,6 V
Three phase appliances 1.06 x rated voltage
divided by √3:..........................................................:
Leakage current between I (mA) Max. allowed I (mA)
L/N and accessible earthed metal parts 0,04 0,75
L/N and accessible plastic parts 0,02 0,25
16.2 (3) TABLE: Leakage current (220 V sample of PE-09) P
Single phase appliances: 1.06 x rated voltage ......: 1,06x220=233,2 V
Three phase appliances 1.06 x rated voltage
divided by √3:..........................................................:
Leakage current between I (mA) Max. allowed I (mA)
L/N and accessible earthed metal parts 0,04 0,75
L/N and accessible plastic parts 0,02 0,25
16.2 (4) TABLE: Leakage current (127 V sample of PE-09) P
Single phase appliances: 1.06 x rated voltage ......: 1,06x127=134,6 V
Three phase appliances 1.06 x rated voltage
divided by √3:..........................................................:
Leakage current between I (mA) Max. allowed I (mA)
L/N and accessible earthed metal parts 0,04 0,75
L/N and accessible plastic parts 0,02 0,25
TRF No. IEC60335_2_15I
Page 72 of 84 Report No.: NBES140100003101
IEC 60335-2-15
16.3 (1) TABLE: Electric strength (220 V sample of PE-12 and PE-09) P
Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
L/N and accessible earthed metal parts 1250 No
Internal wiring and accessible plastic parts 1750 No
L/N and accessible plastic parts 3000 No
Supply cord and accessible metal parts 1250 No
16.3 (2) TABLE: Electric strength (127 V sample of PE-12 and PE-09) P
Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
L/N and accessible earthed metal parts 1250 No
Internal wiring and accessible plastic parts 1250 No
L/N and accessible plastic parts 2500 No
Supply cord and accessible metal parts 1250 No
17 (1) TABLE: Overload protection, temperature rise (220 V sample of PE-12) P
Test voltage (V): 1,06x220=233,2 V
Ambient, t1 (°C): 19,3
Ambient, t2 (°C): 18,9
Thermocouple locations T (°C) Max. T (°C)
Pri. winding of transformer 94,6 165
Sec. winding of transformer 104,7 165
Remark: 1) Test condition: the output winding was loaded with 1,5 times the rated output current, the
transformer was operated at 1,06 times the rated input voltage. 2) Until steady conditions were established.
17 (2) TABLE: short circuit secondary terminals of transformer, temperature rise (220 V P
sample of PE-12)
Test voltage (V): 1,06x220=233,2 V
Ambient, t1 (°C): 19,5
Ambient, t2 (°C): 19,7
Thermocouple locations T (°C) Max. T (°C)
Pri. winding of transformer 113,7 165
Sec. winding of transformer 131,8 165
Remark: 1) Test condition: secondary terminals of transformer was short circuit, the transformer was operated
at 1,06 times the rated input voltage. 2) Until steady conditions were established.
TRF No. IEC60335_2_15I
Page 73 of 84 Report No.: NBES140100003101
IEC 60335-2-15
17 (3) TABLE: Overload protection, temperature rise (127 V sample of PE-12) P
Test voltage (V): 1,06x127=134,6 V
Ambient, t1 (°C): 19,4
Ambient, t2 (°C): 19,6
Thermocouple locations T (°C) Max. T (°C)
Pri. winding of transformer 96,4 165
Sec. winding of transformer 101,7 165
Remark: 1) Test condition: the output winding was loaded with 1,5 times the rated output current, the
transformer was operated at 1,06 times the rated input voltage. 2) Until steady conditions were established.
17 (4) TABLE: short circuit secondary terminals of transformer, temperature rise (127 V P
sample of PE-12)
Test voltage (V): 1,06x127=134,6 V
Ambient, t1 (°C): 19,0
Ambient, t2 (°C): 19,1
Thermocouple locations T (°C) Max. T (°C)
Pri. winding of transformer 122,9 165
Sec. winding of transformer 133,1 165
Remark: 1) Test condition: secondary terminals of transformer was short circuit, the transformer was operated
at 1,06 times the rated input voltage. 2) Until steady conditions were established.
19.13 (1) TABLE: Abnormal operation, temperature rises (220 V sample of PE-12) P
Thermocouple locations dT (K) Max. dT (K)
Supply cord insulation 62,7 150
Test corner 95,1 150
Ambient of thermal link 157,2 Reference
Control panel 48,7 Clause 30.1
Bottom enclosure 160,5 Clause 30.1
Pri. winding of transformer 87,6 °C 165 °C
Sec. winding of transformer 86,9 °C 165 °C
Remark: the most unfavourable results were recorded.
19.13 (2) TABLE: Abnormal operation, temperature rises (127 V sample of PE-12) P
Thermocouple locations dT (K) Max. dT (K)
TRF No. IEC60335_2_15I
Page 74 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Supply cord insulation 60,2 150
Test corner 96,7 150
Ambient of thermal link 155,2 Reference
Control panel 52,2 Clause 30.1
Bottom enclosure 163,5 Clause 30.1
Pri. winding of transformer 88,0 °C 165 °C
Sec. winding of transformer 85,1 °C 165 °C
Remark: the most unfavourable results were recorded.
19.13 (3) TABLE: Abnormal operation, temperature rises (220 V sample of PE-09) P
Thermocouple locations dT (K) Max. dT (K)
Supply cord insulation 78,4 150
Test corner 58,8 150
Ambient of thermal link 156,8 Reference
Control panel 56,7 Clause 30.1
Bottom enclosure 142,1 Clause 30.1
Pri. winding of transformer 108,1 °C 165 °C
Sec. winding of transformer 107,2 °C 165 °C
Remark: the most unfavourable results were recorded.
19.13 (4) TABLE: Abnormal operation, temperature rises (127 V sample of PE-09) P
Thermocouple locations dT (K) Max. dT (K)
Supply cord insulation 76,2 150
Test corner 61,3 150
Ambient of thermal link 157,9 Reference
Control panel 60,4 Clause 30.1
Bottom enclosure 140,5 Clause 30.1
Pri. winding of transformer 108,5 °C 165 °C
Sec. winding of transformer 107,7 °C 165 °C
Remark: the most unfavourable results were recorded.
24.1 TABLE: Components P
Object / part No. Manufacturer/ Type / model Technical data Standard Mark(s) of
trademark conformity
TRF No. IEC60335_2_15I
Page 75 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Plug Ching Cheng Wire EL-223 250 V~, 10 A, 2P+E ABNT NBR NM TUV*
Material Co., Ltd. 60884-1 (06/UL-BRAB-
NBR 14136 0009)
(Alternative) Various Various 250 V~, 10 A, 2P+E ABNT NBR NM Brazil
60884-1 approval
NBR 14136
2
Supply cord Ningbo Yunhuan H05VV-F 3x0,75 mm IEC 60227-5 TUV*
Electronics Group (Length≤2 m for (MC, FCV-
Corporation 127 V sample) 8332-Revisao
04)
2
(Alternative) Various H05VV-F 3x0,75 mm IEC 60227-5 Brazil or VDE
(Length≤2 m for approval
127 V sample)
Connector Ching Cheng Wire EL-701 250 V~, 10 A, C13 IEC 60320-1 UL*
Material Co., Ltd. EL-701B (07/UL-BRAP-
0001)
Appliance inlet Steady Electronics 2107 250 V~, 10 A, C14, IEC 60320-1 VDE*
Corporation T70 (40011923)
(Alternative) Yueqing Yanhui DB-14 250 V~, 10 A, C14, IEC 60320-1 VDE*
Electronic Co., Ltd. T70 (40032008)
(Alternative) Yueqing Huaconn HC-99 250 V~, 10 A, C14, IEC 60320-1 VDE*
Electronics Co., T70 (40032734)
Ltd.
Pressure control Foshan Li An Da YL-113E 250 V~, 10 A, IEC 61058-1 VDE*
Electric Appliance YL-113F T200, 1E4 (40020732)
Co., Ltd. YL-113C
Thermal link Therm-O-Disc G4A00 250 V~, 10 A, IEC 60691 VDE*
Europe B.V. Tf: 144 °C (40017228)
(Alternative) Zhongshan Sheng SPF139 250 V~, 10 A, IEC 60691 VDE*
Ping Thermal Tf: 142 °C (40004430)
Protectors Co., Ltd.
(Alternative) Zhongshan Longde RY142 250 V~, 10 A, IEC 60691 TUV*
Electrial Co., Ltd. Tf: 142 °C (B 13 05
67446 021)
Internal wiring Shenzhen Mysun 3122 200 °C, 300 V, IEC 60335-2-15 UL*
Insulation Materials 18 AWG IEC 60335-1 (E239689)
Co., Ltd. +tested with
appliance
(Alternative) Foshan City 3122 200 °C, 300 V, IEC 60335-2-15 UL*
Shunde Zhenglang 18 AWG IEC 60335-1 (E313243)
Metalware Electric +tested with
Apparatus Co., Ltd. appliance
TRF No. IEC60335_2_15I
Page 76 of 84 Report No.: NBES140100003101
IEC 60335-2-15
(Alternative) Nizing Electric Co., 3122 200 °C, 300 V, IEC 60335-2-15 UL*
Ltd. 18 AWG IEC 60335-1 (E215834)
+tested with
appliance
(Alternative) Zhuhai Hengwange 3122 200 °C, 300 V, IEC 60335-2-15 UL*
Electronics Co., 18 AWG IEC 60335-1 (E314186)
Ltd. +tested with
appliance
(Alternative) Zhongshan Hualan 3122 200 °C, 300 V, IEC 60335-2-15 UL*
Electronic Co., Ltd. 18 AWG IEC 60335-1 (E303124)
+tested with
appliance
PCB material Shandong Jinbao ZD-68(G)F V-1 IEC 60335-2-15 UL*
Electronics Co., IEC 60335-1 (E141940)
Ltd. +tested with
appliance
(Alternative) Kingboard KB-3152 V-0 IEC 60335-2-15 UL*
Laminates IEC 60335-1 (E123995)
Holdings Ltd. +tested with
appliance
X2 capacitor Shunde Da Hua HD 104 GPF 275 V~, 0,1 uF, IEC 60384-14 VDE*
Electric Co., Ltd. 40/085/21/C or (40027182)
40/105/21/C
(Alternative) Foshan Shunde MKP-X2 275 V~, 0,1 uF, IEC 60384-14 VDE*
Fongming 40/085/21/C or (40025702)
Electronic Tech. 40/105/21/C
Co., Ltd.
Varistor Guangxi New 10D471K 2500 V~, 25 A, IEC 61051-2-2 VDE*
(for 220 V Future Information 40/85/21 IEC 61051-2 (40030322)
sample) Industry Co., Ltd. IEC 61051-1
(Alternative) Dongguan 471KD10 2500 V~, 25 A, IEC 61051-2-2 VDE*
(for 220 V Littelfuse 40/85/56 IEC 61051-2 (40026161)
sample) Electronics Co., IEC 61051-1
Ltd.
Varistor Guangxi New 10D221K 2500 V~, 25 A, IEC 61051-2-2 VDE*
(for 127 V Future Information 40/85/21 IEC 61051-2 (40030322)
sample) Industry Co., Ltd. IEC 61051-1
(Alternative) Dongguan 221KD10 2500 V~, 25 A, IEC 61051-2-2 VDE*
(for 127 V Littelfuse 40/85/56 IEC 61051-2 (40026161)
sample) Electronics Co., IEC 61051-1
Ltd.
Relay Tianchang City HRW-112LM 250 V~, 10 A; IEC 61810-1 TUV*
Tianren Precision 12 V d.c., T85, 1E4 (R 50151826)
Elect. Co., Ltd.
(Alternative) Ningbo Songle SRU-12VDC- 250 V~, 15 A; IEC 61810-1 TUV*
Relay Co., Ltd. SL-A 12 V d.c., T85, 1E5 (R 50056114)
TRF No. IEC60335_2_15I
Page 77 of 84 Report No.: NBES140100003101
IEC 60335-2-15
NTC Zhongshan Aixin IEC 60335-2-15 Tested with
Electrical IEC 60335-1 appliance
Appliance Co., Ltd
Transformer (for Foshan Shunde EI35- Marked: IEC 60335-2-15 Tested with
220 V sample) Jingwei Electrical & 10501501X input 220 V~, IEC 60335-1 appliance
Electronics Co., output: 10,5 V~,
Ltd. 150 mA, class 120
Transformer (for Foshan Shunde EI35- Marked: IEC 60335-2-15 Tested with
127 V sample) Jingwei Electrical & 10501501X input 127 V~, IEC 60335-1 appliance
Electronics Co., output: 10,5 V~,
Ltd. 150 mA, class 120
- Transformer Jiangmen City XUEW-UL@ Class 130 IEC 60335-2-15 UL*
winding Jiang Ci Electrical IEC 60335-1 (E192838)
Appliances +tested with
Enterprise Co., Ltd. appliance
- Insulation Technol Tape 365S*(a) 130 °C IEC 60335-2-15 UL*
paper (Singapore) PTE 366F*(b) IEC 60335-1 (E148410)
Ltd. 363S*(c) +tested with
368F*(d) appliance
-Transformer Foshan Shunde PBT IEC 60335-2-15 Tested with
bobbin Jingwei Electrical & IEC 60335-1 appliance
Electronics Co.,
Ltd.
Fuse link XC Electronics 5F-Series 250 V~, 10 A, F IEC 60127-2 VDE*
(Shen Zhen) Corp. IEC 60127-1 (40009609)
Ltd.
Heating element Zhongshan Aixin 220 V~, 900 W IEC 60335-2-15 Tested with
(for 220 V Electrical IEC 60335-1 appliance
sample of PE- Appliance Co., Ltd.
12)
Heating element Zhongshan Aixin 127 V~, 900 W IEC 60335-2-15 Tested with
(for 127 V Electrical IEC 60335-1 appliance
sample of PE- Appliance Co., Ltd.
12)
Heating element Zhongshan Aixin 220 V~, 800 W IEC 60335-2-15 Tested with
(for 220 V Electrical IEC 60335-1 appliance
sample of PE- Appliance Co., Ltd.
09)
Heating element Zhongshan Aixin 127 V~, 800 W IEC 60335-2-15 Tested with
(for 127 V Electrical IEC 60335-1 appliance
sample of PE- Appliance Co., Ltd.
09)
Silicone tube Shenzhen SGS-15 IEC 60335-2-15 UL*
Wahchangwei SGS-25 IEC 60335-1 (E233804)
Industrial Co., Ltd. SGS-40 +tested with
appliance
TRF No. IEC60335_2_15I
Page 78 of 84 Report No.: NBES140100003101
IEC 60335-2-15
(Alternative) Jiangyin Yuanda HST* 600 V, 200 °C, IEC 60335-2-15 UL*
Electrical Material VW-1 IEC 60335-1 (E246632)
Co., Ltd. +tested with
appliance
(Alternative) CHERN-FWUH HST-1* 600 V, 200 °C, IEC 60335-2-3 UL*
Enterprise Co., Ltd. VW-1 IEC 60335-1 (E221462)
+tested with
appliance
(Alternative) Shenzhen SRS-70* 600 V, 200 °C, IEC 60335-2-15 UL*
Wahchangwei VW-1 IEC 60335-1 (E233803)
Industrial Co., Ltd. +tested with
appliance
Bottom Zhongshan Aixin PP Min. thickness: 2,1 IEC 60335-2-15 Tested with
enclosure/ Electrical mm IEC 60335-1 appliance
control panel Appliance Co., Ltd.
(red for PE-12)
Bottom Zhongshan Aixin PP Min. thickness: 2,1 IEC 60335-2-15 Tested with
enclosure/ Electrical mm IEC 60335-1 appliance
control panel Appliance Co., Ltd.
(black for PE-09)
PCB box Zhongshan Aixin PP Min. thickness: 1,0 IEC 60335-2-15 Tested with
Electrical mm IEC 60335-1 appliance
Appliance Co., Ltd.
Wire connector Zhongshan Aixin PP IEC 60335-2-15 Tested with
Electrical IEC 60335-1 appliance
Appliance Co., Ltd.
Alternative main Zhongshan Aixin IEC 60335-2-15 Tested with
PCB for all Electrical IEC 60335-1 appliance
models (without Appliance Co., Ltd.
fuse link, X2
capacitor and
varistor)
1)
An asterisk indicates a mark which assures the agreed level of surveillance
28.1 TABLE: Threaded part torque test P
Threaded part identification Diameter of thread Column number Applied torque ( Nm )
(mm) (I, II, or III)
Screws for fixing enclosure 3,9 II 1,2
Screws for fixing PCB 2,9 II 0,5
Screws for fixing earthing 3,5 II 0,8
terminal
29.1 TABLE: Clearances P
Overvoltage category ... : II
Type of insulation:
TRF No. IEC60335_2_15I
Page 79 of 84 Report No.: NBES140100003101
IEC 60335-2-15
Rated impulse Min. cl Basic Functional Supplementary Reinforced Verdict / Remark
voltage (V): (mm)
330 0,5* N/A
500 0,5* N/A
800 0,5* N/A
1 500 0,5*/** N/A
2)
2 500 1,5 1) 3) 2) P
2)
4 000 3,0 4) P
6 000 5,5** N/A
8 000 8,0** N/A
10 000 11,0** N/A
*) The value is increased to 0,8mm for pollution degree 3
*) If the construction is affected by wear, distortion, movement of the parts or during assembly, the value is
increased by 0,5 mm
Remark:
1) Basic insulation:
Between earthed heating tube and live parts (outside of sealing ring): Cl.=Cr.=4,5 mm
Between earthed heating tube and live parts (inside of sealing ring): Cl.=Cr.=1,4 mm
2) Supplementary insulation:
Internal wire to accessible plastic enclosure (Min.): Cl.=Cr.=4,4 mm
3) Functional insulation:
Between L/N of appliance inlet: Cl.=Cr.=3,6 mm
4) Reinforced insulation:
Between accessible plastic enclosure and live parts: Cl.=Cr.=12,0 mm
29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P
Working voltage Creepage distance
(V) (mm)
Pollution degree
1 2 3 Type of insulation
Material group Material group
) ) )
I II IIIa/IIIb I II IIIa/IIIb B* S* R* Verdict
≤50 0,2 0,6 0,9 1,2 1,5 1,7 1,9 N/A
≤50 0,2 0,6 0,9 1,2 1,5 1,7 1,9 N/A
≤50 0,4 1,2 1,8 2,4 3,0 3,4 3,8 N/A
>50 and ≤125 0,3 0,8 1,1 1,5 1,9 2,1 2,4 N/A
>50 and ≤125 0,3 0,8 1,1 1,5 1,9 2,1 2,4 N/A
TRF No. IEC60335_2_15I
Page 80 of 84 Report No.: NBES140100003101
IEC 60335-2-15
>50 and ≤125 0,6 1,6 2,2 3,0 3,8 4,2 4,8 N/A
>125 and ≤250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 1) P
>125 and ≤250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 2) P
>125 and ≤250 1,2 2,6 3,6 5,0 6,4 7,2 8,0 4) P
>250 and ≤400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A
>250 and ≤400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A
>250 and ≤400 2,0 4,0 5,6 8,0 10,0 11,2 12,6 N/A
>400 and ≤500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 N/A
>400 and ≤500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 N/A
>400 and ≤500 2,6 5,0 7,2 10,0 12,6 14,2 16,0 N/A
>500 and ≤800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A
>500 and ≤800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A
>500 and ≤800 3,6 6,4 9,0 12,6 16,0 18,0 20,0 N/A
>800 and ≤1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A
>800 and ≤1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A
>800 and ≤1000 4,8 8,0 11,2 16,0 20,0 22,0 25,0 N/A
>1000 and ≤1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A
>1000 and ≤1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A
>1000 and ≤1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0 N/A
>1250 and ≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A
>1250 and ≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A
>1250 and ≤1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0 N/A
>1600 and ≤2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A
>1600 and ≤2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A
>1600 and ≤2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0 N/A
>2000 and ≤2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0 N/A
>2000 and ≤2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0 N/A
>2000 and ≤2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0 N/A
>2500 and ≤3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A
>2500 and ≤3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A
>2500 and ≤3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0 N/A
>3200 and ≤4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A
>3200 and ≤4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A
>3200 and ≤4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0 N/A
TRF No. IEC60335_2_15I
Page 81 of 84 Report No.: NBES140100003101
IEC 60335-2-15
>4000 and ≤5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A
>4000 and ≤5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A
>4000 and ≤5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0 N/A
>5000 and ≤6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A
>5000 and ≤6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A
>5000 and ≤6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0 N/A
>6300 and ≤8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A
>6300 and ≤8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A
>6300 and ≤8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0 N/A
>8000 and ≤10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A
>8000 and ≤10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A
>8000 and ≤10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0 N/A
>10000 and ≤12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A
>10000 and ≤12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A
>10000 and ≤12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0 N/A
)
* , B=Basic, S=Supplementary and R=Reinforced
29.2 TABLE: Creepage distances, functional insulation P
Working voltage Creepage distance
(V) (mm)
Pollution degree
1 2 3
Material group Material group
I II IIIa/IIIb I II IIIa/IIIb Verdict / Remark
≤50 0,2 0,6 0,8 1,1 1,4 1,6 1,8 N/A
>50 and ≤125 0,3 0,7 1,0 1,4 1,8 2,0 2,2 N/A
>125 and ≤250 0,4 1,0 1,4 2,0 2,5 2,8 3,2 P
>250 and ≤400 0,8 1,6 2,2 3,2 4,0 4,5 5,0 N/A
>400 and ≤500 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A
>500 and ≤800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A
>800 and ≤1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A
>1000 and ≤1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A
>1250 and ≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A
>1600 and ≤2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A
>2000 and ≤2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N/A
TRF No. IEC60335_2_15I
Page 82 of 84 Report No.: NBES140100003101
IEC 60335-2-15
>2500 and ≤3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A
>3200 and ≤4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A
>4000 and ≤5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A
>5000 and ≤6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A
>6300 and ≤8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A
>8000 and ≤10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A
>10000 and ≤12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A
TRF No. IEC60335_2_15I
Page 83 of 84 Report No. : NBES140100003101
IEC 60335-2-15
TABLE 30 RESISTANCE TO HEAT, FIRE AND TRACKING (appended table) P
2)
Component Manufacturer Type Ball pressure test Tracking Glow wire test Needle- Verdict
test flame
75°C cl. 11 125°C cl. 19 [CTI/ PTI] GWT GWT GWT GWT GWFI test 1)
+40°C +25°C 550°C 650°C 750°C 850°C 850°C
PCB 1,2 175 V X X X P
PCB box 1,4 175 V X X X P
Transformer 0,9 175 V X X X P
bobbin
Wire connector 1,7 175 V X X X P
Bottom 1,0 X X P
enclosure/
control panel (red
for PE-12)
Bottom 1,0 X X P
enclosure/
control panel
(black for PE-09)
Appliance inlet X X X P
Relay X X X P
X2 capacitor X X P
Varistor X X P
Silicone tube X X P
TRF No. IEC60335_2_15I
Page 84 of 84 Report No. : NBES140100003101
IEC 60335-2-15
Remark:
1)
surrounding parts are subjected to the needle-flame test of Annex E
2)
impression diameters are stated in mm
3)
All alternative components were tested and the most unfavourable results were recorded.
<End of Report>
TRF No. IEC60335_2_15I
Page 1 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: PE-12
View:
[ X ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: PE-12
View:
[ ] general
[ X ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 2 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Marking on control panel for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: PE-12
View:
[ ] general
[ ] front
[ X ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 3 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: PE-12
View:
[ ] general
[ ] front
[ ] rear
[ X ] right
[ ] left
[ ] top
[ ] bottom
Detail of: PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ X ] left
[ ] top
[ ] bottom
Page 4 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ X ] top
[ ] bottom
Detail of: PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ X ] bottom
Page 5 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Open view of lid for PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Level marking of container for PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 6 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Lid for PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Relief valve Safety valve
Detail of: Open view of PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 7 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Appliance inlet position for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Open view for PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 8 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Open view for PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Position of
thermal link
and pressure
control
Detail of: Appliance inlet for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 9 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Open view of PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Safety device
position for all
models
Detail of: Main PCB for all models (except for transformer and varistor)
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 10 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Earthing terminal for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: NTC position for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 11 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Main PCB for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Position of
fuse link,
X2 capacitor
and varistor
Detail of: Main PCB for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 12 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Transformer for 220 V sample
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Transformer for 127 V sample
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 13 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Control PCB for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Control PCB for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 14 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Control panel
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Two layers of
insulation
cover for all
models
Detail of: Earthing terminal for all models
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 15 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Heating element for 127 V of PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Heating element for 127 V of PE-12
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 16 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: PE-09
View:
[ X ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: PE-09
View:
[ ] general
[ X ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 17 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: PE-09
View:
[ ] general
[ ] front
[ X ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: PE-09
View:
[ ] general
[ ] front
[ ] rear
[ X ] right
[ ] left
[ ] top
[ ] bottom
Page 18 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ X ] left
[ ] top
[ ] bottom
Detail of: PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ X ] top
[ ] bottom
Page 19 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ X ] bottom
Detail of: Open view of lid for PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 20 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Level marking of container for PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Open view for 127 V sample of PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 21 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Heating element for 127 V sample of PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Open view for 220 V sample of PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 22 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Heating element for 127 V sample of PE-09
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Detail of: Alternative main PCB for 127 V sample (without fuse link, X2 capacitor and varistor)
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
Page 23 of 23
Annex I Photo documentation Report No.: NBES140100003101
Pressure Cooker
PE-09, PE-12
Detail of: Alternative main PCB for 220 V sample (without fuse link, X2 capacitor and varistor)
View:
[ ] general
[ ] front
[ ] rear
[ ] right
[ ] left
[ ] top
[ ] bottom
<End of Annex I>