Alarm and Monitoring List Torlak Shipyard [Link].
63 RA-B10801
Engine Safety Stop
Q'ty/ Loca-
Eng. Supply
tion Specifications
Over Speed 1 M Control Operated at 118~120% of rated speed by Over
Panel Speed Signal(12) of above Speed Relay
Lub. Oil Press. Low 1 M E Press. switch Abnormal ON≦0.15MPa
Auto Slowdown
Q'ty/ Loca-
Eng. Supply
tion Specifications
H.T.F.W. Press. Low 1 M E Press. transmitter Abnormal ON≦0.03MPa
with override function
H.T.F.W. Temp. High 1 M E Temp. switch Abnormal ON≧100℃
with override function
Monitoring Equipments
Gauges fitted on Eng. Alarm or Remote display
Parts Name Q'ty/ Q'ty/
Eng. Specifications Eng. Specifications
Tachometer
(For Engine)
1 Electrical (0~1200min-1 ) 5
Tachometer
(For Propeller)
1 Electrical (-300~+300min-1 ) 5
Tachometer 1 Electrical (0~50000min )
-1 Eng.
Cont.
Sensor 4-20mA (Range:0~50000min-1 )
(For Turbo-charger) Panel Alarm≧44400min-1
Kind of Press. Gauge Bourdon tube, Size:φ60
Glycerin filled Type
P Lub. Oil 1 Scale : 0~1.0MPa 1 Sensor 4-20mA(0~1.0MPa)
R at Eng. inlet Normal : 0.55~0.60MPa Alarm ≦ 0.20MPa
E (shipyard supply)
S Lub. Oil - Scale : 0~1.0MPa 1 Sensor 4-20mA(0~1.0MPa)
S at LO filter inlet
U Fuel Oil 1 Scale : 0~2.0MPa 1 Sensor 4-20mA(0~1.0MPa)
R at Eng. inlet Normal : 0.5~0.55MPa Alarm ≦ 0.40MPa
E (shipyard supply)
High Temp. Fresh Water 1 Scale : 0~0.6MPa 1 Sensor 4-20mA(0~0.6MPa)
at Eng. inlet Alarm ≦ 0.03MPa
(shipyard supply)
Low Temp. Fresh Water 1 Scale : 0~0.6MPa 1 Sensor 4-20mA(0~0.6MPa)
at Eng. inlet Alarm ≦ 0.03MPa
(shipyard supply)
Boost Air at Eng. inlet 1 Scale : 0~0.6MPa
Starting Air at Eng. Inlet 1 Scale : 0~2.5MPa 1 Press Switch for Alarm
Normal : 0.9~1.1MPa Abnormal OFF ≦ 0.8MPa
Gauges fitted on Eng. Alarm or Remote display
Parts Name Q'ty/ Q'ty/
Eng. Specifications Eng. Specifications
Kind of Thermometer Bar type Thermometer
with Protective case
T Lub. Oil Engine 1 Scale : 0~100℃ 1 Sensor Pt 100 Ω(0~200℃)
E inlet Alarm ≧ 85℃
M (shipyard supply)
P Lub. Oil 1 Scale : 0~100℃
E Cooler inlet
R High Temp. Engine 1 Scale : 0~120℃
A Fresh Water inlet
T Engine 1 Scale : 0~120℃ 1 Sensor Pt 100 Ω(0~200℃)
U outlet Alarm ≧ 95℃
R (shipyard supply)
E Low Temp. Lub. Oil 1 Scale : 0~100℃
Fresh Water Cooler inlet
A/C inlet 1 Scale : 0~100℃
A/C outlet 1 Scale : 0~100℃
Fuel Oil Engine Inlet 1 Scale : 0~200℃ 1 Sensor Pt 100 Ω(0~200℃)
Alarm ≧ ○℃(at 17mm2/s)
Alarm ≦ ○℃(at 9mm2/s)
(shipyard supply)
Exh. Gas Each Cyl. 6 Scale : 0~500℃
outlet
T/C inlet 2 Scale : 0~650℃
T/C outlet 1 Scale : 0~500℃
Boost Air A/C inlet 1 Scale : 0~300℃
A/C outlet 1 Scale : 0~300℃ 1 Sensor Pt 100 Ω(0~200℃)
Alarm ≧ 75℃
(shipyard supply)
O F.O. Leakage Tank of 1 Abnormal OFF at High Level
T High Press. Pipes
H Differencial Press. of 1 Differencial Press. Indicator 1 Alarm (s/y monitoring system)
E Lub. Oil Strainer Abnormal OFF ≧ 0.12MPa
R Differencial Press. of 1 Alarm switch
S No.2 Fuel Oil Strainer Abnormal OFF ≧ 0.07MPa
Differencial Press. of 1 Alarm switch
No.3 Fuel Oil Strainer Abnormal OFF ≧ 0.07MPa
L.O. Low Press. Switch for 1 Press Switch for Alarm
T/C Inlet Abnormal OFF ≦ 0.2MPa