STRUCTURE AND FUNCTION, MAINTENANCE STANDARD Machine monitor

T/M initial learning setting


Learning for correcting the solid difference of transmission

Learning data reset


Issue the learning data reset command to reset all learning data
stored in the non-volatile memory.

Display of T/M initial learning and procedure for resetting data

1. Hold down the „ SW and < SW for 5 seconds or more at the


same time, and change to the ID entry screen. (Figure 1)

2. Use the < and > SW to enter ID, and press the ‘ SW to en-
ter the service person screen.

3. Use the < and > SW to display the sensor initialization selec-
tion screen (Figure 2), and press the ‘ SW to decide the
value.

4. Use the < and > SW to display the T/M initial learning screen
(Figure 3) of set item 1.

5. Press the ‘ SW; the T/M initial learning set screen


(Figure 4) appears.

6. -1 When the initial learning is not executed, the initial learn-


ing reset screen (Figure 4) appears.
-2 When the initial learning is executed, the initial learning
set screen (Figure 4) appears.

7. If the „ SW is pressed here, the initial learning reset confir-


mation screen (Figure 5) appears.

8. -1 When resetting, use the < switch to select [YES], then


press the „ SW.
-2 When not resetting, select NO, then press the „ SW.

9. Press the „ SW: the learning state set or reset screen


(Figure 4) appears.

Press the „ SW, and confirm that the monitor indicator is in the
initial learning reset state (Figure 4). Resetting is then complet-
ed. If the initial learning is required, reset once even when the
monitor indicator first displays the learning reset state.

WA470-5H / WA480-5H 10-269


Machine monitor STRUCTURE AND FUNCTION, MAINTENANCE STANDARD

Initial learning procedure

Preparation for machine

1. Start the engine.

2. Display the T/M oil temperature on the real-time monitor.

3. Operate the gear shift lever and forward-reverse lever to oil


the inside of the transmission sufficiently.

N2 Î F2 Î F1 Î F2 Î F3 Î F4 Î F3 Î F2 Î N2 Î R2
Î N2

Each speed level must be held for 2 sec. or more.

4. Lift the T/M oil temperature to 55 to 70°C.

The learning operation must be performed at the specified oil


temperature; so, exactly adjust the oil temperature.

Confirm that the machine is normal (no fault is detected).

Initial learning procedure


1. Execute the initial learning from the machine standby state
above. (Do not stop the engine.)

2. Use the real-time monitor to confirm that the T/M oil temper-
ature is in the range from 55 to 70°C.

The T/M controller [ECMV OIL TEMP] is displayed on the


real-time monitor. If the T/M oil temperature is illegal, adjust
it to 55 to 70°C.

3. Operate the gear shift lever and forward-reverse lever to


change the transmission.

N2 Î F2 Î F1 Î F2 Î F3 Î F4 Î F3 Î F2 Î N2 Î R2
Î N2

For the first N2, hold for 5 sec. or more, and hold for 3 sec.
or more at each speed level.

Operate the machine in the engine low idling, manual switch


ON, T/M cut-off switch OFF, and (lock-up switch OFF)
states.

The gear shift must be operated at actual travel or on-base


travel.

4. After all the initial learning is completed, the initial learning


set screen (TUNED) appears.

Ordinarily, the initial learning is completed by performing the


gear shift operation until this initial learning set screen
(TUNED) appears.

10-270 WA470-5H / WA480-5H