0% found this document useful (0 votes)
37 views5 pages

Load Solution

The document provides details on seismic definition parameters for a proposed 5-story commercial building project located in Bunawan, Davao City, Philippines, including fault information, soil and structure types, seismic coefficients, and load calculations for dead load, fluid load, live load, and special live loads.

Uploaded by

Lorejean R. Flor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views5 pages

Load Solution

The document provides details on seismic definition parameters for a proposed 5-story commercial building project located in Bunawan, Davao City, Philippines, including fault information, soil and structure types, seismic coefficients, and load calculations for dead load, fluid load, live load, and special live loads.

Uploaded by

Lorejean R. Flor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

SEISMIC DEFINITION

 Location of the Project: Bunawan, Panacan Davao City


 Fault Name: Central Davao Fault System
 Fault Segment: New- Carmen Fault
 Distance from the Location: 12.4 km
 Occupancy (Category): 5 – Story Commercial Building (Category III)
 Soil Type: Stiff Soil Profile
 Structure: Concrete
 Moment Resisting Frame: Special Reinforced Concrete
 Seismic Importance Factor, I = 1.0
 Seismic Zone: Zone 4 (Z = 0.4)
 Earthquake Source: M = 7.5 (Type A)
 Near – source Factor, Na = 0.91 (Type A)
 Near – source Factor, Nv = 0.91 (Type A)
 Seismic Coefficient, Ca = 0.44Na = 0.44(0.91) = 0.4004
 Seismic Coefficient, Cv = 0.64Nv = 0.64(0.91) = 0.5804
 Numerical Coefficient, Rx = Ry = 8.5

SEISMIC HAZARD PARAMETERS


FLUIDS (LOAD CASE)

WATER TANK LOAD = (unit weight of water) (height of the tank) = (9.81) (3) = 29.43 kN/m 2

DEADLOAD

For uniformly distributed Wall load = Unit wt. of wall x Thickness of wall x Height of wall

 For exterior wall & Interior wall = 150mm


22x0.15x3.6 =11.88 kN/m
22x0.15x3.4 =11.22 kN/m
22x0.15x1.2 = 3.96 kN/m

 For firewall = 200mm


22x0.2x3.6 =15.84 kN/m
22x0.2x3.4 =14.96 kN/m
22x0.2x1.2 = 5.28 kN/m

 For Glass Wall = 12mm


22x0.012x3.6 = 0.95 kN/m
22x0.012x3.4 = 0.90 kN/m
22x0.012x1.2 = 0.317 kN/m

 Wall at roofdeck
22x0.15x3 = 9.9 kN/m

For stair load


1ST FLOOR TO 2ND FLOOR
3.6 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
2RD FLOOR TO 3RD FLOOR
3.4 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
3RD FLOOR TO 4RD FLOOR
3.4 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
4RD FLOOR TO 5RD FLOOR
3.4 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
UNIFORM LOAD = [(approx. thickness) (1 m width) (unit weight of concrete)] / (width of the stairs) = [(4.471 m
x 2 sides x 0.189m) (1.75 m) (23.56)] / (2) /(5) = 9.95 Kn/M = 10 Kn/m

For weight pressure:


Wp = (Unit wt. of concrete x thickness of the slab) + superimposed loads
Superimposed loads
 Tiles: 1.10
 Mechanical/electrical duct lines: 0.20
 Ceiling: 0.05
kN
Wp = (23.56 3 x 0.125) + (1.10 + 0.20 + 0.05) = 4.295 kpa
m

SPECIAL LIVE LOADS

 COMMON ELEVATOR = F =mg = (907 kg) (9.81) / 1000 = 8.898 kN


Load = (8.898 kN / 2.34 m2) (2) = 7.606 kN/m2

 SERVICE ELEVATOR = F =mg = (1135 kg) (9.81) / 1000 = 11.134 kN


Load = (11.134 kN / 3.75 m2) (2) = 5.938 kN/m2

NSCP 2015 LOAD FACTORS


 SUPERIMPOSED LOADS

 LIVELOAD
 SEISMIC