Call us at 1-866-299-0989 to purchase this product!
Megaplex-2100/2104
Modular Integrated Access Multiplexers
FEATURES
PCM, ADPCM digitization
Flexible Integrated Access
Multiplexers Integrated data, voice/fax and video traffic with DS0 cross-connect Multiple E1/T1 or fractional E1/T1 main links, with combined TDM capacity of 8 Mbps (124 timeslots)
10/100 Mbps IP access link
for transparent circuit extension over IP, using RADs TDMoIP technology Ring topology support: Self-healing TDM E1/T1 rings Resilient Fast Ethernet Ring (RFER) technology providing Fast Ethernet networks with self-healing protection within 50 msec
and G.723.1 low-bit-rate compressed voice Optional redundant configurations for critical applications Wide range of I/O modules supporting multiple channels: 120 high speed data 132 low speed data 55 full BRI (2B+D) 120 PCM voice Two chassis types: MP-2100 (4U-high) housing up to 12 modules MP-2104 (2U-high) compact version housing up to five modules V5 support for standard POTS and ISDN interface to the local exchange R2 signaling
Ethernet LAN modules Built-in fiber optic and xDSL
modems for reduced deployment and maintenance costs ASCII terminal for local management RADview SNMP management with graphical user-interface on PC or UNIX (HP OpenView) platform Telnet support for remote management
Non-volatile, Flash memory
for software upgrade and configuration download DL (download) and TFTP support for Common Logic software upgrade Standard management protocols: SLIP, PPP, PPPHDLC, IP Over Frame Relay (RFC 1450) and RIP2
Megaplex-2100/2104
Modular Integrated Access Multiplexers
DESCRIPTION
Megaplex-2100/2104 is a modular
integrated access TDM multiplexer, that enables integration of multiple dedicated data, voice, ISDN, video and LAN channels over multiple main (network) links. Megaplex features a traffic payload capacity of up to 124 DS0 timeslots. This 8 Mbps capacity can be transmitted over 4 full E1 or 5 full T1 links, or alternatively, over multiple fractional E1/T1 links. design with wide choice of I/O (user interface) modules supports applications ranging from small campus networks to multi-site corporate networks or extensive carrier access solutions. Due to Megaplexs standards adherence, central office based cross-connect units (DACS) can separate voice and data, sending each to the appropriate carrier or service.
Megaplex enables carriers to
SYSTEM
Chassis
successfully deploy bundled services, ISDN services and Internet access. The integration of a broad range of services makes Megaplex a cost-effective access device, with reduced deployment and maintenance costs.
The chassis is available in two basic
variants: Megaplex-2100 (4U high) chassis providing slots for up to 12 main link and I/O modules Megaplex-2104 (2U high) chassis providing slots for up to 5 main link and I/O modules.
The equipment conforms to
international standards, ensuring compatibility in multi-vendor environments worldwide.
Timing
TDMoIP
Multiple system timing options are
available: Internal crystal oscillator clock Clock received from any link (loopback) Clock from any high speed module channel External station (master) clock Adaptive timing received from any bundle (with ML-IP only). Any clock source can be set as fallback in the event of primary clock source failure.
Megaplexs flexible, modular
Megaplex offers an optional IP
main link module that transmits TDM traffic directly over IP networks. This TDMoIP access module converts user TDM traffic into IP packets transmitted on 10/100BaseT or 100BaseF Ethernet networks. Megaplex with TDMoIP technology provides a cost-effective, versatile and modular solution for transmitting legacy TDM traffic over IP networks. This is especially suitable for large corporations, utilities or power companies that are seeking a gradual migration to IP networks.
Megaplex-2100/2104
Modular Integrated Access Multiplexers
System Redundancy
The Megaplex system also supports
two RAD proprietary types of ring redundancy, provided by its main link modules: E1/T1 Ring: Similar to SDH, the E1/T1 ring features ring redundancy in a closed dual-ring topology: one path propagates data clockwise and the other counterclockwise. Each Megaplex can receive data through two different paths, and selects only the signal received through one of the paths for processing. In case of failure, the failed segment is bypassed by using the second path, providing self-healing in less than five seconds.
Megaplexs modular, distributed
architecture enables redundancy at different levels of the network and provides a system with no single point of failure. attained by an optional redundant power supply and common logic module (MP-2100 chassis only).
System hardware redundancy is
1:1 protection switching on the
main link modules protects against network or cable failure. Additional ML modules can be installed and interconnected via Y-cables to provide protection against ML hardware failures. backup for IP transmissions (functions similarly to E1/T1 link parallel TX redundancy). activates alternate routing. This is achieved by storing multiple configuration databases and flipping (switching) between them in case of any network event.
RFER: The TDMoIP link module features RADs Resilient Fast Ethernet Ring (RFER) technology for creating self-healing Ethernet ring networks. RFER reroutes traffic within 50 msec of a ring segment failure, providing fast redundancy performance similar to SDH networks. Survivability is further enhanced by RFERs scalable support for multiple rings. RFER can carry up to 40 E1 or 50 T1 links with no limit on the number of nodes.
The built-in, non-blocking, DS0
Bundle redundancy provides
cross-connect matrix enables freely routing any channels timeslots to any link. This allows Megaplex to maximize its efficiency by splitting voice and data channels and redirecting the traffic, via separate links, to the appropriate service. enables routing timeslots from any link to any other link. This facilitates drop insert, bypass or broadcast multi-link applications.
In case of link failure, Megaplex
The cross-connect matrix also
APPLICATIONS
Figure 1. Point-to-Point Topology Megaplex is suitable for integrating all the traffic requirements between two sites, over a wide variety of E1/T1 links: leased lines, fiber optic, HDSL, radio or satellite. Multiple fractional or full E1/T1 links can support load sharing between the links, as well as automatic backup, with prioritization of voice and data services. Link redundancy is supported, providing 1:1 protective switching between any two links (within 50 msec between dual links of same ML module).
Megaplex-2100/2104
Modular Integrated Access Multiplexers
A total of 124 timeslots can be
allocated, either for transmission of I/O channels or for bypassing timeslots between links of different modules.
The V5.2 standard allows
V5.1 AND V5.2 INTERFACE SUPPORT
oversubscription of services based on dynamic, on-demand assignment of timeslots for optimal utilization of a given bandwidth on the physical link. V5.2 main link can serve as a V5.2 endpoint gateway, allowing voice, ISDN and fractional/full E1 services with payload of up to 120 channels.
R2 SIGNALING SUPPORT
Main link (ML) modules support
A Megaplex unit equipped with a
V5, the ETSI standard interface,
operates between the access network and the Class 5 switch for basic telephony, ISDN and semi-permanent leased lines, allowing oversubscription of the number of users/channels over a given V5.2 interface capacity. Megaplex incorporates a V5 main link interface to facilitate connection of residential and SOHO users of PSTN and ISDN services to local exchanges with a V5 interface. standard allowing connection of telephone services to a Class 5 switch without oversubscription.
R2 signaling with transparent MFC/DECADIC, so that Megaplex can be placed between an older R2-PBX and a digital (E1-CAS) PBX. The MFC/DECADIC signaling is not terminated by Megaplex, but passed on to the PBX. In addition to the ITU-T standard R2 protocol, several predefined national PTT protocols, as well as user-defined variations, are also supported. Since the R2 signaling support is provided by the ML, all voice module types support R2.
V5.1 is a static flavor of the V5
Figure 2. Resilient Fast Ethernet Ring (RFER) Provides 50 msec Self-healing IP Networks Megaplex ML-IP with RADs RFER technology, enables corporations, campuses, utilities, and transportation companies to create highly reliable IP networks with 50 msec link protection switching, using dark fiber or copper wire in a ring topology.
Megaplex-2100/2104
Modular Integrated Access Multiplexers
COMMON LOGIC MODULES
Two dedicated ports are provided
The Common Logic (CL) module
controls the Megaplexs operation and is the interface for its configuration and management. It stores the application software and up to 10 configuration databases (depending on complexity) for multiple independent configurations. The CL also stores all system event information. Flash EPROM for software download is provided.
on the CL module for management purposes. One port has a 9-pin DCE interface for direct connection of a management terminal or PC. The other is ordered with one of the following interface options: Ethernet 10BaseT (UTP) Ethernet 10Base2 (BNC) V.24/RS-232 DTE.
Two outbound relays can be
assigned to be triggered by any user-selected major or minor alarm, for routing of Megaplex alarms to outside indicators, such as buzzers and bells.
An input voltage detector,
intended for sensing external events (coming from temperature alarm sensors etc), generates internal alarms, which are sent to the NMS station and reported to the user.
Figure 3. Mesh Corporate Network RADs DXC (Digital Cross-connect) DACS complements Megaplexs own cross-connect capabilities, to provide a comprehensive network solution. DXC enables flexible routing of timeslots between different Megaplex and other E1/T1 equipment sites, together with an integrated network management for easy control and monitoring.
Megaplex-2100/2104
Modular Integrated Access Multiplexers
MAIN LINK MODULES
E1/T1 Main Links
I/O MODULES
Low Speed Data Modules
Up to 11 I/O modules of any kind
can be placed in an MP-2100 chassis (up to 4 I/O modules in an MP-2104). If more I/O modules are required, Megaplex units can be cascaded.
Sub-rate multiplexer modules for
low speed (2.4 to 19.2 kbps) synchronous and asynchronous data channels employ standard X.50, X.58 or SDM (DS0-B) multiplexing techniques.
Megaplex TDM E1/T1 main link
modules allow direct connection to a wide range of services, eliminating the need for external equipment. Multiple active links can operate in each chassis. Additional modules can also be installed for link redundancy. used for a broad range of configurations: from single link non-redundant operation, to multiple full or fractional E1/T1 link applications supporting drop & insert and broadcast. fiber optic modems (range up to 100 km/62 miles) or E1 link modules with xDSL modems (range up to 10.6 km/6.6 miles) are available. These special links reduce the cost of local loop solutions by lowering equipment deployment and maintenance costs. increase efficiency and support 1:1 protective switching between the two links within 50 msec.
High Speed Data Modules
Low speed modules with
High speed data interface modules
provide leased line data services, operating at multiples of 56 or 64 kbps, up to 2.048 Mbps, connecting routers, bridges, front-end processors, etc.
The various ML modules can be
sync/async V.24/RS-232 channels, with independent channel rates up to 64 kbps are available. End-to-end control signals are also supported.
E1 interface modules with built-in
Voice/Fax and Voice Compression Modules
E1/T1 link modules with built-in
xDSL modems enable cost-effective long range deployment of high speed services over 2- or 4-wire copper lines. Range is up to 4.0 km. extend ISDN services over non-ISDN facilities, supporting data, voice and video applications. The U interface modules include IDSL technology for last mile applications.
Voice/fax modules provide
ISDN BRI (U or S) modules
The dual-trunk main link modules
toll-quality voice transmission using standard PCM (ITU-T G.711), as well as ADPCM (G.726), MPMLQ (G.723.1), or P-CELP 4.8 kbps compression. Standard analog interfaces are available for direct connection to POTS, public payphones, LB (local battery) field phones, PBX extensions or 2/4-wire E&M trunks. Alternatively, voice compression modules with E1 and T1 digital PBX interfaces are available. Loop, wink and ground-start signaling are also supported.
TDMoIP Main Link
The unique ML-IP main link
module converts the TDM bit stream delivered over the internal Megaplex back plane into IP packets, for transmission over IP networks. ML-IP provides three Ethernet ports, with 10/100BaseT or 100BaseF interfaces. The module conforms to IEEE 802.3 and 802.3u and provides reliable, high quality of service (QoS), including VLAN tagging and priority labeling (ToS). bundles with VLAN tagging for supporting point-to-multipoint applications. Duplicate bundles can be transmitted simultaneously on different paths for redundancy.
ML-IP places TDM timeslots into IP
GUI-based RADview Network Management System for Megaplex-2100/2104
Megaplex-2100/2104
Modular Integrated Access Multiplexers
Digital voice compression modules
connect PBX trunks with greater bandwidth utilization (compression ratio of up to 10:1). The modules employ a choice of high quality voice compression methods, including G.723.1 at 6.4 kbps per channel, or G.729A at 8 kbps. The modules support Group III fax and modem relay, at user-selectable standard rates of up to 14.4 kbps, featuring transparent timeslot transfer, voice activity detection, silence suppression, and comfort noise generation. Module versions are offered with single/dual T1 (up to 24/48 channels), or single/dual E1 (up to 30/60 channels) interfaces.
The user-friendly GUI-based
RADview network management applications facilitate management of both individual units and entire networks. enables end-to-end path management of MAP devices, providing physical and logical graphic views of all network links and service paths of the system.
The signaling monitoring capability
useful for voice application diagnostics enables Megaplex to display a snapshot of the current ABCD signaling bit states of any selected timeslot that carries voice traffic. frequency of occurrence, are stored in CLs alarm status buffer. Last 256 alarms are kept in a separate alarm history buffer. read online by the management system from any node. User-set alarm masking, filtering and inversion, as well as 5-level prioritization are also supported.
The RADview-SC/TDM application
All alarms, including state and
The management connection can
LAN Modules
Ethernet router/bridge modules
enable LAN to LAN extension over E1/T1 services, offering various L2 capabilities.
MANAGEMENT
Megaplex can be fully configured
locally, using an ASCII terminal. It can also be managed remotely via Telnet, SNMP element management applications, or end-to-end path management application. management station by means of its SNMP agent (via a SLIP/PPP or TCP/IP connection). Network management applications provide centralized control of all network nodes, including interface configuration, connection setup, alarms and monitoring.
be established by the following methods: Out-of-band, using the Ethernet management port. This simple and efficient method takes advantage of IP bandwidth on demand, while saving link bandwidth for user traffic Inband over a dedicated timeslot, supporting standard PPP, FR encapsulation, and RIP2 protocols Over a modem link or over a FRAD, via the control port of the remote unit.
Alarm status can be automatically
NEBS-COMPLIANT EQUIPMENT
Megaplex-2100 is also offered in a
special NEBS-compliant version which meets the Type 3 and Type 4 requirements, and permits reliable operation in harsher environmental conditions. Contact your RAD distributor for more information on NEBS-compliant equipment.
DIAGNOSTICS
Megaplex incorporates test features
for rapid fault detection and easy maintenance. Upon power-up, all system and modules perform self-testing. Any problems are reported to the management system. Loopbacks, BERTs and tone injections can be run on individual channels or main links, towards both the network and user side.
Megaplex communicates with the
Megaplex-2100/2104
Modular Integrated Access Multiplexers
SPECIFICATIONS
Main Link and I/O Modules Configuration
By ASCII Terminal or PC, connected to terminal interface or via Telnet Using RADview SNMP management system See accompanying data sheets
Physical MP-2104 (2U-high)
Built-in power supply (optional built-in voice ringer or ISDN power feeder is available) 1 CL module slot 5 slots for I/O and ML modules Height: 9 cm (3.5 in) (2U) Width: 44 cm (17 in) Depth: 33 cm (13 in) Weight: less than 6 kg (13 lb)
(All weights are for fully loaded units)
Maximum Output Power
MP-2100 (without Ringer): AC: 200W DC: 200W MP-2104: AC: 120W DC: 120W ACw/Ringer: 225W DCw/Ringer: 290W
Maximum Input Power
MP-2100 (without Ringer): AC: 250W DC: 250W MP-2104: AC: 160W DC: 160W ACw/Ringer: 300W DCw/Ringer: 350W
Physical MP-2100 (4U-high)
2 power supply module slots 2 CL module slots 12 slots for I/O and ML modules Height: 18 cm (7 in) (4U) Width: 44 cm (17 in) Depth: 33 cm (13 in) Weight: less than 12 kg (26 lb)
Power Supply Input
MP-2100: AC: 100, 115 or 230 VAC DC: 24 or -48 VDC MP-2104: AC: 100, 115 or 230 VAC DC: 24 or -48 VDC
Environment
Temperature Operating: 0 to 45C (32 to 113F) (NEBS version: up to 55C (+131F) Storage: -20 to+70C (-4 to +160F Humidity: up to 90%, non-condensing
NEBS-Compliant Megaplex-2100 Chassis
Megaplex-2100/2104
Modular Integrated Access Multiplexers
ORDERING
BASIC UNITS
Standard Megaplex-2100/2104 systems are comprised of a Basic Unit, as well as Main Link and I/O Modules, which are ordered separately. Basic units include a chassis, single Common Logic (CL) module, single power supply, and power supply cables. See separate module data sheets for main link and I/O module details and ordering information.
ORDERING OPTIONS * Specify power supply input voltage: 100 for 100 VAC 115 for 115 VAC 230 for 230 VAC 24 for 24 VDC 48 for -48 VDC
SUPPLIED ACCESSORIES AC power cord (with AC power supply only) DC adapter plug (with DC power supply only)
MP-2100/*/&/2# 4U-high chassis with 12 module slots and CL.2 common logic module MP-2104/*/+/2# 2U-high chassis with 5 module slots and CL.2 common logic module SYSTEM MODULES
System modules can be ordered separately for redundancy or special requirements
RM-MP-MX-23/19 & Specify redundancy (MP-2100 only): Hardware kit for mounting one R for full (2 x PS, 2 x CL) MP-2100 unit into both 19-inch and RP for partial (2 x PS, 1 x CL) ETSI 23-inch racks Default is for 1 x PS, 1 x CL MP2104/RM + Specify RI for built-in ringer Hardware kit for mounting one (MP-2104 only) MP-2104 unit into both 19-inch and # Specify CL second management port ETSI 23-inch racks (in addition to standard 9-pin DCE port): UTP for Ethernet 10BaseT (UTP) BNC for Ethernet 10Base2 (BNC) V24 for V.24/RS-232 DTE OPTIONAL ACCESSORIES CBL-DB9F-DB9M-STR Control port cable
MP-2100M-PS200/* Higher Power Supply Module for MP-2100 (available only for AC input) MP-2100M-CL.2/# Common Logic Module
[Link] International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel: 972-3-6458181 Fax: 972-3-6498250 Email: market@[Link] North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel: (201) 529-1100 Toll free: 1-800 444-7234 Fax: (201) 529-5777 Email: market@[Link] 764-100-03/06
19882006 RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
Specifications are subject to change without prior notice.