Functional transparency:
Design-oriented and individual
Curtain wall systems from RP Technik
Mullion-transom curtain wall system, steel add-on curtain walls, and wood and aluminium add-on curtain walls
Unique design and
innovation with expertise
With RP’s curtain wall systems, many architects
and metalworkers have given buildings worldwide
their distinctive features. Owing to its material pro-
perties, steel makes it possible to achieve the very
transparent structures required by cutting-edge
designs. In consultation with planners and users, the
systems are continually being optimised.
Individualised and detailed planning for large-
scale projects is what characterises the specialists
at RP Technik. Numerous examples, from office and
trade fair buildings to shopping malls, railway stations
or airports demonstrate the ways RP curtain wall
systems made of steel can be used in filigree and
unusual architecture.
UNIQUE DESIGN
With RP’s curtain wall systems, many architects and metalworkers have given buildings worldwi-
de their distinctive features. Owing to its material properties, steel makes it possible to achieve
the very transparent structures required by cutting-edge designs.
NARROW FACE WIDTHS AND LOW CONSTRUCTION DEPTHS
The curtain wall systems from RP Technik are characterised by particularly narrow face widths.
Compared to an aluminium curtain wall, 36% less depth is required for an RP Technik steel cur-
tain wall.
WIDEST POSSIBLE SPANS
The steel systems from RP Technik are real powerhouses amongst curtain wall systems and
meet the highest static requirements - making extraordinary spans possible. Even seemingly
impracticable slender geometries with high glass weights can be realized by the overall concept
of the systems.
Your
advantages
in focus
Particularly narrow face widths
with an extraordinary load-bearing
capacity allow for maximum
freedom of design.
Technical properties:
· Wind pressure EN 13116: Pressure up to 3.0 kN/m²
and suction to -4.8 kN/m²
· Air permeability EN 12152: AE
· Tightness against driving rain force EN 12152:
RE / ENV 13050: 400 Pa. / 1200 Pa.
· Heat insulation with rectangular foam piping from
Uf = 0.87 W/(m²K)
· High heat insulation with double foam piping from
Uf = 0.56 W/(m²K)
· Impact strength 14019: E5/15
· Break-in resistance RC2 and RC3
· Sound insulation up to Rw (C; Ctr) = 47 (-2;-7) dB
· Bullet resistant DIN EN 1522 for RP-tec 55-1: FB 4 NS
· Structural glazing / all-glass curtain wall with weather sealing
· Hilti direct fastening system for fixing the base profile on a steel
substructure
· MAG-hole spot welding, suitable for subsequently galvanizing parts
· Nail method for fixing basic profile to a wooden substructure
· 0° roof testing according to EN 13830 / system release for overhead
glazing up to 5° incline
· Bullet proofing FB7 with the RP-ISO-hermetic 60N system
Steel curtain wall Aluminium curtain wall
Your
advantages
in focus
36% lower construction depth with
RP Technik steel curtain wall
Advantages of steel over aluminium:
· The larger span widths of steel curtain walls result
in higher transparency with less material usage.
· With the same profile cross-sections, larger spans
can be achieved with steel profiles.
· Due to a modulus of elasticity that is 3 times higher
than aluminium, steel has a much higher static load
capacity.
· With the same profile cross-sections, the deflection is 3
times lower for steel than for aluminium.
· With the same load and deflection, smaller steel profiles
may be used.
· Lightweight steel constructions offer the optimum conditions
Aluminium Steel
for visual comfort.
· A slender supporting structure allows for a wide range of design
freedom and innovative building structures.
RP-ISO-hermetic 45N
Mullion-transom curtain wall systems
RP 1786 CA RP 1787 CA RP 1788 CA RP 1789 CA
RP 1787 CI RP 1788 CI RP 1789 CI
RP 1787 XA RP 1788 XA
RP 1787 ZA RP 1788 ZA
RP 1790 CA RP 1815 CA 306 130 306 135 306 139 ▲
RP 1790 CI RP 1815 CI
RP 1790 XA
RP 1790 ZA
AA = steel S235 JR bright rolled, 6.000 mm
CI = steel continuously hot dip coated,
7.500 mm
Pressure profiles / cover profiles CA = steel continuously hot dip coated,
6.000 mm
CR = steel continuously hot dip coated,
3.000 mm
XA = stainless steel 1.4301 (304),
surface raw material 2B, 6.000 mm
XR = stainless steel 1.4301 (304),
surface raw material 2B, 3.000 mm
ZA = stainless steel 1.4301 (304),
430 055 CA 430 050 XA 411 550 ZA 411 560 ZA outer surface ground, size 220-240,
foiled, 6.000 mm
ZR = stainless steel 1.4301 (304),
outer surface ground, size 220-240,
foiled, 3.000 mm
AL = aluminium EN AW 6060, state T66, 6.000
mm
▲ = Chloroprene
° = self-adhesive
403 831 AL 403 840 AL 403 851 AL 403 890 AL 413 630 AL 413 640 AL 413 690 AL
Gaskets
300 381 300 610 ▲ 300 560 305 180
System section
RP-ISO-hermetic 45N
RP-ISO-hermetic 60N
Mullion-transom curtain wall systems
RP 1800 CA RP 1802 CA RP 1804 CA RP 1806 CA
RP 1802 CI RP 1804 CI RP 1806 CI
RP 1802 XA RP 1804 XA RP 1806 XA
RP 1802 ZA RP 1804 ZA RP 1806 ZA
6,0
200
RP 1807 CA 551 020 (= 6 m) / 551 050 (= 12 m) 305 170 305 175 305 179 ▲
RP 1807 CI
Pressure profiles / cover profiles AA = steel S235 JR bright rolled, 6.000 mm
CI = steel continuously hot dip coated,
7.500 mm
CA = steel continuously hot dip coated,
6.000 mm
CR = steel continuously hot dip coated,
3.000 mm
XA = stainless steel 1.4301 (304),
surface raw material 2B, 6.000 mm
XR = stainless steel 1.4301 (304),
430 065 CA 430 060 XA 411 530 ZA 411 540 ZA
surface raw material 2B, 3.000 mm
ZA = stainless steel 1.4301 (304),
outer surface ground, size 220-240,
foiled, 6.000 mm
ZR = stainless steel 1.4301 (304),
outer surface ground, size 220-240,
foiled, 3.000 mm
AL = aluminium EN AW 6060, state T66, 6.000
mm
403 531 AL 403 560 AL 403 900 AL 403 950 AL 413 510 AL 413 520 AL 413 530 AL 413 540 AL ▲ = Chloroprene
° = self-adhesive
Gaskets
300 381 300 610 ▲ 300 560 305 180
System section
RP-ISO-hermetic 60N
RP-tec 55 / 55 plus
Mullion-transom curtain wall systems
55
35 55 85 115 150 171
RP 91 710 2 RP 91 711 2 RP 91 712 2 RP 91 713 2 RP 91 714 2 RP 91 715 2
RP 91 710 3*) RP 91 711 3 RP 91 712 3 RP 91 713 3
RP 91 710 4*) RP 91 711 4 RP 91 712 4 RP 91 713 4
55
55
20
20
85 115
RP 91 720 2 RP 91 721 2 RP 92 703 2 RP 92 772 2 RP 92 773 2 RP 92 774 2 RP 92 775 2
RP 91 720 3 RP 91 721 3
RP 91 720 4 RP 91 721 4
RA 93 769 6 RA 93 770 6 RA 93 774 6 RA 93 775 6 RA 93 776 6 RA 93 777 6 RA 93 741 6 RA 93 745 6 RA 93 771 6 RA 93 772 6 RA 93 773 6
Pressure profiles / cover profiles
55
15 20 45 25 10 10
RP 92 750 3 RP 92 760 4 RP 92 761 4 RP 92 762 4 RP 92 755 1 RP 92 757 1 RP 92 758 1 RP 92 759 1
53
55
2 12 15 20 25
RP 92 756 1 RP 92 784 1 RP 92 760 1 RP 92 761 1 RP 92 768 1 RP 92 704 1
Gaskets Accessories
RA 93 720 6 RA 93 725 6 RA 93 726 6 RA 93 727 6 RA 93 715 6 RA 93 713 6 RA 93 710 6 RA 93 718 6 RA 93 78x 6 RA 93 790 6
System section
RP-tec 55
End digit 0 = steel S235JR, bright rolled, 6.000 mm
End digit 1 = aluminium EN AW 6060, state T66,
6.000 mm
End digit 2 = steel S280GD continuously hot-dip
coated, 6.000 mm
End digit 3 = stainless steel, 1.4401 (316), surface
raw material 2B, 6.000 mm
End digit 4 = stainless steel, 1.4401 (316), outer
surfaces ground , size 400, foiled, 6.000 mm
End digit 5 = aluminium black, 6.000 mm
R = Delivery length 3.000 mm
*) Price and Delivery on demand
RA 93 79x 6
Narrow face widths and
maximum load-bearing capacity:
Multilateral system
RP-tec 50-1 / 50-1 plus /
50-1 HA / 50-1 HA plus
Steel add-on curtain walls, and wood and aluminium add-on curtain walls
RP 92 706 0 RP 92 706 1 RA 93 761 6 RA 93 762 6 RA 93 765 6 RA 93 766 6 RA 93 767 6 RA 93 768 6
RP 92 706 2
End digit 0 = steel S235JR, bright rolled, 6.000 mm
End digit 1 = aluminium EN AW 6060, state T66,
6.000 mm
RA 93 750 6 RA 93 751 6 RA 93 754 6 RA 93 755 6 RA 93 756 6 End digit 2 = steel S280GD continuously hot-dip
coated, 6.000 mm
End digit 3 = stainless steel, 1.4401 (316), surface
raw material 2B, 6.000 mm
End digit 4 = stainless steel, 1.4401 (316), outer
surfaces ground , size 400, foiled, 6.000 mm
End digit 5 = aluminium black, 6.000 mm
R = Delivery length 3.000 mm
*) Price and Delivery on demand
Pressure profiles / cover profiles
50
50
50
50
48
48
48
32
25 10 10 2 2 15 20 12
RP 92 753 1 RP 92 786 1 RP 92 787 1 RP 92 788 1 RP 92 754 1 RP 92 770 1 RP 92 780 4 RP 92 781 4 RP 92 771 1
50
50
50
50
50
12 15 20 25 30
RP 92 783 1 RP 92 780 1 RP 92 781 1 RP 92 785 1 RP 92 884 1
Gaskets Accessories
RA 93 710 6 RA 93 711 6 RA 93 712 6 RA 93 713 6 RA 93 715 6 RA 93 718 6 RA 93 725 6 RA 93 726 6 RA 93 727 6 RA 93 759 6 RA 93 78x 6 RA 93 790 6
System sections
+50°C
+20°C
+15°C
+10°C
-10°C
Heated curtain wall
RP-tec 50-1 plus, RP-tec 55-1 plus
RP-tec 50-1 RP-tec 50-1 HA RP-tec 50-1 HA plus
RA 93 79x 6
RP-tec 55-1 / 55-1 HA /
55-1 HA plus
Steel add-on curtain walls, and wood and aluminium add-on curtain walls
RP 92 705 0 RP 92 705 1 RA 93 739 6 RA 93 737 6 RA 93 746 6 RA 93 747 6 RA 93 748 6 RA 93 749 6
RP 92 705 2
End digit 0 = steel S235JR, bright rolled, 6.000 mm
End digit 1 = aluminium EN AW 6060, state T66,
6.000 mm
End digit 2 = steel S280GD continuously hot-dip
RA 93 731 6 RA 93 735 6 RA 93 742 6 RA 93 743 6 RA 93 744 6 coated, 6.000 mm
End digit 3 = stainless steel, 1.4401 (316), surface
raw material 2B, 6.000 mm
End digit 4 = stainless steel, 1.4401 (316), outer
surfaces ground , size 400, foiled, 6.000 mm
End digit 5 = aluminium black, 6.000 mm
R = Delivery length 3.000 mm
*) Price and Delivery on demand
Pressure profiles / cover profiles
53,5
55
55
55
55
55
55
53
53
15 20 45 25 10 10 2
RP 92 750 3 RP 92 760 4 RP 92 761 4 RP 92 762 4 RP 92 755 1 RP 92 757 1 RP 92 758 1 RP 92 759 1 RP 92 756 1
55
55
55
55
55
48
32
2 12 12 15 20 25 30
RP 92 770 1 RP 92 771 1 RP 92 784 1 RP 92 760 1 RP 92 761 1 RP 92 768 1 RP 92 834 1
Gaskets Accessories
RA 93 710 6 RA 93 711 6 RA 93 712 6 RA 93 713 6 RA 93 715 6 RA 93 718 6 RA 93 725 6 RA 93 726 6 RA 93 727 6 RA 93 759 6 RA 93 78x 6 RA 93 790 6
System sections
RP-tec 55-1 RP-tec 55-1 HA RP-tec 55-1 HA plus
RA 93 79x 6
RP-tec 60-1 / 60-1 HA
Steel add-on curtain walls, and wood and aluminium add-on curtain walls
RP 92 705 0 RP 92 705 1 RA 93 706 6 RA 93 707 6 RA 93 708 6
RP 92 705 2
End digit 0 = steel S235JR, bright rolled, 6.000 mm
End digit 1 = aluminium EN AW 6060, state T66,
6.000 mm
End digit 2 = steel S280GD continuously hot-dip
coated, 6.000 mm
End digit 3 = stainless steel, 1.4401 (316), surface
raw material 2B, 6.000 mm
Pressure profiles / cover profiles End digit 4 = stainless steel, 1.4401 (316), outer
surfaces ground , size 400, foiled, 6.000 mm
End digit 5 = aluminium black, 6.000 mm
R = Delivery length 3.000 mm
*) Price and Delivery on demand
53
60
60
60
58
58
32
2
12 15 20 10 12
RP 92 710 1 RP 92 714 1 RP 92 713 1 RP 92 712 1 RP 92 866 1 RP 92 771 1 RP 92 756 1
Gaskets
RA 93 710 6 RA 93 711 6 RA 93 712 6 RA 93 713 6 RA 93 715 6 RA 93 718 6 RA 93 725 6 RA 93 726 6 RA 93 727 6 RA 93 759 6
System sections
RP-tec 60-1 RP-tec 60-1 HA
RP-tec 80-1 / 80-1 HA
Steel add-on curtain walls, and wood and aluminium add-on curtain walls
RP 92 705 0 RP 92 705 1 RA 93 795 6 RA 93 797 6 RA 93 787 6 RA 93 788 6
RP 92 705 2
End digit 0 = steel S235JR, bright rolled, 6.000 mm
End digit 1 = aluminium EN AW 6060, state T66,
Pressure profiles / cover profiles 6.000 mm
End digit 2 = steel S280GD continuously hot-dip
coated, 6.000 mm
End digit 3 = stainless steel, 1.4401 (316), surface
raw material 2B, 6.000 mm
End digit 4 = stainless steel, 1.4401 (316), outer
surfaces ground , size 400, foiled, 6.000 mm
80
80
78
78
End digit 5 = aluminium black, 6.000 mm
R = Delivery length 3.000 mm
15 20 *) Price and Delivery on demand
RP 92 720 1 RP 92 721 1 RP 92 726 1 RP 92 725 1
Gaskets
RA 93 710 6 RA 93 711 6 RA 93 712 6 RA 93 713 6 RA 93 715 6 RA 93 718 6 RA 93 725 6 RA 93 726 6 RA 93 727 6 RA 93 759 6
System sections
RP-tec 80-1 RP-tec 80-1 HA
RP-tec VARIO
Accessories
RA 93 781 6 - RA 93 785 6 RA 675 415 RA 686 980
Gaskets
RA 93 723 8 RA 93 724 8
System sections
RP-tec VARIO -
in combination with a steel add-on curtain wall
RP-tec VARIO -
in combination with a mullion-transom curtain wall system
Filigree, functional and
transparent: these are the
RP Technik curtain wall systems
Welser Profile Deutschland GmbH
Edisonstraße 23
59199 Bönen / DEUTSCHLAND
Tel (+49 2383) 914-0
Fax (+49 2383) 914-5555
[email protected]
Welser Profile Austria GmbH
3341 Ybbsitz / ÖSTERREICH
Tel (+43 7443) 800-0
Fax (+43 7443) 800-4111
[email protected] 3264 Gresten / ÖSTERREICH
Tel (+43 7487) 410-0
Fax (+43 7487) 410-4111
RP Technik GmbH Profilsysteme
Edisonstraße 4
59199 Bönen / DEUTSCHLAND
Tel (+49 2383) 91 49-0
Fax (+49 2383) 91 49-222
[email protected] Ferdinand-Braun-Straße 26
74074 Heilbronn / DEUTSCHLAND
Imprint
© RP Technik GmbH Profilsysteme
Layout and Outwork: arche-nova.at
www.rp-technik.com
Printed by Becker Druck
Änderungen und Irrtümer vorbehalten.
Modifications and errors reserved.
Sous réserve de modifications et d’erreurs.
edition 01-EN-01.2018 • Art.-Nr. 1161031