MX2 Omron Datasheet
MX2 Omron Datasheet
System configuration
Power
supply
MCCB Software
USB cable
Filter
MX2
Braking resistor
DC reactor
Choke
Ground
3G3MX2-AB002-@-E@
C: IP54 ready for customization
MX2 series
E: Europe standard
A: IP20
D: IP54 (Includes Class 2 EMC filter) P: Finless
~
2: Three-phase 200 VAC
4: Three-phase 400 VAC 150: 15,0 kW
200 V class
Single-phase: 3G3MX2-@ B001 B002 B004 B007*1 B015 B022 – – – – –
Three-phase: 3G3MX2-@ 2001 2002 2004 2007 2015 2022 2037 2055 2075 2110 2150
For VT setting 0.2 0.4 0.55 1.1 2.2 3.0 5.5 7.5 11 15 18.5
Motor
kW*2
For CT setting 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
200 VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
200 CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
characteristics
240 CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
Rated output current (A) at VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Rated output current (A) at CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Max. output voltage Proportional to input voltage: 0 to 240 V
Max. output frequency 400 Hz
Single-phase 200 to 240 V 50/60 Hz
Rated input voltage and frequency
supply
Power
400 V class
Three-phase: 3G3MX2-@ 4004 4007 4015 4022 4030 4040 4055 4075 4110 4150
For VT setting 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
Motor
kW*1
For CT setting 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
380 VT 1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
380 CT 1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
characteristics
480 CT 1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
Rated output current (A) at VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Rated output current (A) at CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Max. output voltage Proportional to input voltage: 0 to 480 V
Max. output frequency 400 Hz
Rated input voltage and frequency 3-phase 380 to 480 V 50/60 Hz
supply
Power
current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), LOG1~LOG3 (Logic out-
Output signals
put signals), WAC (capacitor life warning), WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warn-
ing), LOC (Low load), MO1~MO3 (general outputs for Drive Programming), IRDY (inverter ready), FWR (forward operation),
RVR (reverse operation), MJA (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequen-
cy command source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) perfor-
mance monitor), OP (option control signal), NO (no function)
Free-V/f, manual/automatic torque boost, output voltage gain adjustment, AVR function, reduced voltage start, motor data
selection, auto-tuning, motor stabilization control, reverse running protection, simple position control, simple torque control,
torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, non-stop operation at
instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower
limiters, jump frequencies, curve accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine adjustment of start
Standard functions
frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage accel/decel, stop mode
selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold
function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display
restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry,
frequency pull-in restart, frequency matching, overload restriction, over current restriction, DC bus voltage AVR
Analogue inputs 2 analogue inputs 0 to 10 V (10 K), 4 to 20 mA (100 )
Pulse train input terminal 0 to 24 V, up to 32 kHz
Accel/Decel times 0.01 to 3,600.0 s (line/curve selection), 2nd accel/decel setting available
Status indicator LED’s Run, Program, Alarm, Power, Hz, Amps
Display
Digital operator: Available to monitor 32 items: frequency reference, output current, output frequency…
Motor overload protection Electronic Thermal overload relay and PTC thermistor input
Instantaneous overcurrent 200% of rated current
Dual rating:
Protection functions
Degree of protection IP20, Varnish coating on PCB & IP54 (For 3G3MX2-D@ type)
Ambient humidity 90% RH or less (without condensation)
Storage temperature –20°C to 65°C (short-term temperature during transportation)
Ambient temperature*1 10C to 50°C (Both the carrier frequency and output current need to be reduced over 40°C)
Installation Indoor (no corrosive gas, dust, etc.)
Installation height Max. 1,000 m
Vibration 5.9 m/s2 (0.6G), 10 to 55 Hz
*1 Some types of 3G3MX2-D requires special derating depending on installation conditions and carrier frequency selected. Check the manual for details.
‚g‚š ‚`‚k‚l
‚g‚š ‚`‚k‚l
‚` ‚o‚q‚f
‚` ‚o‚q‚f
‚r‚s‚n‚o
‚r‚s‚n‚o ‚q‚t‚m ‚q‚d‚r‚d‚s
‚q‚t‚m ‚q‚d‚r‚d‚s
‚q‚t‚m ‚o‚v‚q
‚R‚f‚R‚l‚w‚Q ?@?@‚h‚m‚u‚d‚q‚s‚d‚q
‚h‚m‚u‚d‚q‚s‚d‚q
‚g‚š ‚`‚k‚l
‚` ‚o‚q‚f
H1 H H1 H ‚q‚t‚m ‚r‚s‚n‚o
‚q‚d‚r‚d‚s
H1 H
t
5
Figure 1
D D Figure 2
Figure 3
D1 D
2,6
D1
D1
D2
D2
Inverter model Dimensions in mm
Voltage class Figure
3G3MX2-A@ W W1 H H1 t D D1 D2 d Weight (kg)
Single-phase B001-E 1 68 56 128 118 – 109 13.5 – – 1.0
200 V B002-E 1.0
B004-E 122.5 27 1.1
B007-E 2 108 96 128 118 170.5 55 4.4 4.5 1.4
B015-E 1.8
B022-E 1.8
Three-phase 2001-E 1 68 56 128 118 – 109 13.5 – – 1.0
200 V 2002-E 1.0
2004-E 122.5 27 1.1
2007-E 145.5 50 1.2
2015-E 2 108 96 128 118 170.5 55 4.4 4.5 1.6
2022-E 1.8
2037-E 3 140 128 128 118 5 170.5 55 4.4 2.0
2055-E 140 122 260 248 6 155 73.3 6 6 3.0
2075-E 3.4
2110-E 180 160 296 284 7 175 97 5 7 5.1
2150-E 220 192 350 336 7 175 84 5 7 7.4
Three-phase 4004-E 2 108 96 128 118 – 143.5 28 – – 1.5
400 V 4007-E 170.5 55 1.6
4015-E 170.5 1.8
4022-E 1.9
4030-E 1.9
4040-E 3 140 128 128 118 5 170.5 55 4.4 4.5 2.1
4055-E 122 260 248 6 155 73.3 6 6 3.5
4075-E 3.5
4110-E 180 160 296 284 7 175 97 5 7 4.7
4150-E 5.2
Option board
67.6 44.9
28.6
60.0
27.9
53.1
Note: Option boards could be fitted inside the IP54 model.
W W
W Ø 4.5
Ø 4.5
Ø 4.5 W1 W1
W1
[Link]. [Link].
[Link].
H1
H1
H
H1
H
H
5 5
5
D Figure 2 D Figure 3
D Figure 1
D1 D1 D1
179.5 309.5
12.5
Figure 1 299.5 Figure 2
12.5
169.5
279.5
150
462.33
482.8
464.74
444
63.5
62.44
298.9
274 317.7
292.7
325
Figure 3
12.5
315 379
Figure 4
11.5
295 369
349
627.04
607
689.85
710.35
18.7
63
281
299.5 311
329.7
Schaffner model
W H L X Y A B M
1×200 V AX-FIM1010-SE@ 70 40 166 156 51 150 50 M5 LINE
AX-FIM1024-SE-V1
AX-FIM1014-SE@ 110 45 166 156 91 150 80 M5
L AX
AX-FIM1024-SE@ 110 50 166 156 91 150 80 M5
LOAD
L1'
N'
AX-FIM3014-SE@ 142 50 171 161 120 150 112 M5
AX-FIM3030-SE@ 140 55 304 290 122 286 112 M5
AX-FIM3050-SE@ 180 55 344 330 160 323 140 M5
Input AC reactor
Single-phase
Dimensions Weight
Voltage Reference
A B C D E F G H kg
200 V AX-RAI02000070-DE 84 113 96 101 66 5 7.5 2 1.22
AX-RAI01700140-DE 84 113 116 101 66 5 7.5 2 1.95
AX-RAI01200200-DE 84 113 131 101 66 5 7.5 2 2.55
AX-RAI00630240-DE 84 113 116 101 66 5 7.5 2 1.95
Three-phase
Dimensions Weight
Voltage Reference
A B2 C2 D E F kg
200 V AX-RAI02800080-DE 120 70 120 80 52 5.5 1.78
AX-RAI00880200-DE 120 80 120 80 62 5.5 2.35
AX-RAI00350335-DE 180 85 190 140 55 6 5.5
AX-RAI00180670-DE 180 85 190 140 55 6 5.5
400 V AX-RAI07700050-DE 120 70 120 80 52 5.5 1.78
AX-RAI03500100-DE 120 80 120 80 62 5.5 2.35
AX-RAI01300170-DE 120 80 120 80 62 5.5 2.50
AX-RAI00740335-DE 180 85 190 140 55 6 5.5
Output AC reactor
Dimensions Weight
Voltage Reference kg
A B2 C2 D E F
200 V AX-RAO11500026-DE 120 70 120 80 52 5.5 1.78
AX-RAO07600042-DE 120 70 120 80 52 5.5 1.78
AX-RAO04100075-DE 120 80 120 80 62 5.5 2.35
AX-RAO03000105-DE 120 80 120 80 62 5.5 2.35
AX-RAO01830180-DE 180 85 190 140 55 6 5.5
AX-RAO01150220-DE 180 85 190 140 55 6 5.5
AX-RAO00950320-DE 180 85 205 140 55 6 6.5
AX-RAO00630430-DE 180 95 205 140 65 6 9.1
AX-RAO00490640-DE 180 95 205 140 65 6 9.1
400 V AX-RAO16300038-DE 120 70 120 80 52 5.5 1.78
AX-RAO11800053-DE 120 80 120 80 52 5.5 2.35
AX-RAO07300080-DE 120 80 120 80 62 5.5 2.35
AX-RAO04600110-DE 180 85 190 140 55 6 5.5
AX-RAO03600160-DE 180 85 205 140 55 6 6.5
AX-RAO02500220-DE 180 95 205 140 55 6 9.1
AX-RAO02000320-DE 180 105 205 140 85 6 11.7
Chokes X
D Motor Dimensions Weight
Reference Øm
diameter kW L W H X Y m kg W Y
AX-FER2102-RE 21 < 2.2 85 22 46 70 – 5 0.1
AX-FER2515-RE 25 < 15 105 25 62 90 – 5 0.2 L
AX-FER5045-RE 50 < 45 150 50 110 125 30 5 0.7
H Ød
Fig 2 Fig 3
Fig 4
Dimensions Weight
Type Fig.
L H M I T G N kg
AX-REM00K1400-IE 1 105 27 36 94 - - - 0.2
AX-REM00K2070-IE
AX-REM00K2120-IE
AX-REM00K2200-IE
AX-REM00K4075-IE 200 27 36 189 - - - 0.425
AX-REM00K4035-IE
AX-REM00K4030-IE
AX-REM00K5120-IE 260 27 36 249 - - - 0.58
AX-REM00K6100-IE 320 27 36 309 - - - 0.73
AX-REM00K6035-IE
AX-REM00K9070-IE 2 200 61 100 74 211 40 230 1.41
AX-REM00K9020-IE
AX-REM00K9017-IE
AX-REM01K9070-IE 3 365 73 105 350 70 - - 4
AX-REM01K9017-IE
AX-REM02K1070-IE 4 310 100 240 295 210 - - 7
AX-REM02K1017-IE
AX-REM03K5035-IE 365 100 240 350 210 - - 8
AX-REM03K5010-IE
Breaker, MCCB or
GFI
R MX2 U (T1)
Power source, (L1) Motor
3-phase or
1-phase, per S V (T2)
inverter model (L2)
W (T3)
T
N(L3)
PD/+1 DC reactor
Intelligent inputs, 24 V (optional)
7 terminals
P24 + – P/+
Forward Braking
Note: For the wiring of Brake unit
intelligent I/O and 1 RB resistor (optional)
analog inputs, be sure to (optional)
use twisted pair/ 2 N/–
shielded cable. Attach Input
the shielded wire for 3/GS1 circuits
each signal to its AL2
Relay contacts,
respective common 4/GS2 type 1 Form C
terminal at the inverter AL0
end only. [5] configurable as
Input impedance of each
5/PTC discrete input or
intelligent input is 4.7 k thermistor input AL1
6
Open collector output
Output circuit
7/EB Freq. arrival signal
11/EDM Load
Thermistor
Short bar PLC
(Source type)
L 12 Load
GND for logic inputs
L +
–
Meter CM2
Termination resistor (200 GND for logic outputs
EO
(Change by slide switch)
L SP
Meter
RS485 Serial communication port
transceiver (RS485/ModBus)
AM
L
L
10 VDC
SN
Analog reference
H
0~10 VDC +
O – RJ45 port
RS485
Approx.10 k (Optional operator port)
4~20 mA transceiver
OI
Approx.100 L
Pulse train input USB (mini-B) port
24 VDC 32 kHz max. L USB (PC communication port)
EA transceiver USB power: Self power
L
L
L Option port Option port connector
GND for analog signals controller
L
L
P/+, RB Braking resistor terminals Connect option braking resistor (if a braking torque is required)
Grounding For grounding (Grounding should conform to the local grounding code.)
3/GS1 Multi-function Input selection 3/safe stop input 1 Factory setting: External trip
4/GS2 Multi-function Input selection 4/safe stop input 2 Factory setting: Reset 27 VDC max
5/PTC Multi-function Input selection 5/PTC thermistor input Factory setting: Multi-step speed reference 1
7/EB Multi-function input selection 7/Pulse train input B Factory setting: Jog
5 to 24 VDC
10 VDC 2 mA
EO Pulse train output LAD frequency
32 kHz max
H Frequency reference power supply 10 VDC 10 mA max
Analog input
signal
11/EDM Discrete logic output 1/EDM output Factory setting: During Run
27 VDC, 50 mA max
12 Discrete logic output 2 Factory setting: Frequency arrival type 1 EDM based on
Digital output
ISO13849-1
signals
SP
Serial communication terminal RS485 Modbus communication
SN
Enclosure 100 mm
50 mm 100 mm
DC reactor MX2
Power
supply MCCB
R/L1
S/L2
T/L3
+1 P/+2
DC reactor
200 V class 400 V class
Max. applicable Current value Inductance Max. applicable Current value Inductance
motor output kW Reference A mH motor output kW Reference A mH
0.2 AX-RC21400016-DE 1.6 21.4 0.4 AX-RC43000020-DE 2.0 43.0
0.4 AX-RC10700032-DE 3.2 10.7 0.7 AX-RC27000030-DE 3.0 27.0
0.7 AX-RC06750061-DE 6.1 6.75 1.5 AX-RC14000047-DE 4.7 14.0
1.5 AX-RC03510093-DE 9.3 3.51 2.2 AX-RC10100069-DE 6.9 10.1
2.2 AX-RC02510138-DE 13.8 2.51 3.0 AX-RC08250093-DE 9.3 8.25
3.7 AX-RC01600223-DE 22.3 1.60 4.0 AX-RC06400116-DE 11.6 6.40
5.5 AX-RC01110309-DE 30.9 1.11 5.5 AX-RC04410167-DE 16.7 4.41
7.5 AX-RC00840437-DE 43.7 0.84 7.5 AX-RC03350219-DE 21.9 3.35
11.0 AX-RC00590614-DE 61.4 0.59 11.0 AX-RC02330307-DE 30.7 2.33
15.0 AX-RC00440859-DE 85.9 0.44 15.0 AX-RC01750430-DE 43.0 1.75
Output AC reactor
200 V class 400 V class
Max. applicable Current value Inductance Max. applicable Current value Inductance
Reference Reference
motor output kW A mH motor output kW A mH
0.4 AX-RAO11500026-DE 2.6 11.50 1.5 AX-RAO16300038-DE 3.8 16.30
0.75 AX-RAO07600042-DE 4.2 7.60
1.5 AX-RAO04100075-DE 7.5 4.10
2.2 AX-RAO03000105-DE 10.5 3.00 2.2 AX-RAO11800053-DE 5.3 11.80
3.7 AX-RAO01830160-DE 16.0 1.83 4.0 AX-RAO07300080-DE 8.0 7.30
5.5 AX-RAO01150220-DE 22.0 1.15 5.5 AX-RAO04600110-DE 11.0 4.60
7.5 AX-RAO00950320-DE 32.0 0.95 7.5 AX-RAO03600160-DE 16.0 3.60
11 AX-RAO00630430-DE 43.0 0.63 11 AX-RAO02500220-DE 22.0 2.50
15 AX-RAO00490640-DE 64.0 0.49 15 AX-RAO02000320-DE 32.0 2.00
Power
supply
B E
MCCB Software
USB cable
A B B B
Input AC Remote operator LCD 5 lines remote Installation accessory
reactor extension cable operator
A
Filter
C
Communication option board
MX2 D
Braking resistor
A
A DC reactor
Choke
A
Motor Output AC reactor
Ground
3G3MX2
Specifications Model
Constant torque Variable torque
Voltage class Standard (IP20) Finless IP54
Max motor kW Rated current A Max motor kW Rated current A
Single-phase 0.1 1.0 0.2 1.2 3G3MX2-AB001-E 3G3MX2-AB001-P-E 3G3MX2-DB001-E/EC
200 V 0.2 1.6 0.4 1.9 3G3MX2-AB002-E 3G3MX2-AB002-P-E 3G3MX2-DB002-E/EC
0.4 3.0 0.55 3.5 3G3MX2-AB004-E 3G3MX2-AB004-P-E 3G3MX2-DB004-E/EC
0.75 5.0 1.1 6.0 3G3MX2-AB007-E 3G3MX2-AB007-P-E 3G3MX2-DB007-EC
1.5 8.0 2.2 9.6 3G3MX2-AB015-E 3G3MX2-AB015-P-E 3G3MX2-DB015-EC
2.2 11.0 3.0 12.0 3G3MX2-AB022-E 3G3MX2-AB022-P-E 3G3MX2-DB022-EC
Three-phase 0.1 1.0 0.2 1.2 3G3MX2-A2001-E 3G3MX2-A2001-P-E 3G3MX2-D2001-E/EC
200 V 0.2 1.6 0.4 1.9 3G3MX2-A2002-E 3G3MX2-A2002-P-E 3G3MX2-D2002-E/EC
0.4 3.0 0.55 3.5 3G3MX2-A2004-E 3G3MX2-A2004-P-E 3G3MX2-D2004-E/EC
0.75 5.0 1.1 6.0 3G3MX2-A2007-E 3G3MX2-A2007-P-E 3G3MX2-D2007-E/EC
1.5 8.0 2.2 9.6 3G3MX2-A2015-E 3G3MX2-A2015-P-E 3G3MX2-D2015-EC
2.2 11.0 3.0 12.0 3G3MX2-A2022-E 3G3MX2-A2022-P-E 3G3MX2-D2022-EC
3.7 17.5 5.5 19.6 3G3MX2-A2037-E 3G3MX2-A2037-P-E 3G3MX2-D2037-EC
5.5 25.0 7.5 30.0 3G3MX2-A2055-E - 3G3MX2-D2055-EC
7.5 33.0 11 40.0 3G3MX2-A2075-E - 3G3MX2-D2075-EC
11 47.0 15 56.0 3G3MX2-A2110-E - 3G3MX2-D2110-EC
15 60.0 18.5 69.0 3G3MX2-A2150-E - 3G3MX2-D2150-EC
Three-phase 0.4 1.8 0.75 2.1 3G3MX2-A4004-E 3G3MX2-A4004-P-E 3G3MX2-D4004-EC
400 V 0.75 3.4 1.5 4.1 3G3MX2-A4007-E 3G3MX2-A4007-P-E 3G3MX2-D4007-EC
1.5 4.8 2.2 5.4 3G3MX2-A4015-E 3G3MX2-A4015-P-E 3G3MX2-D4015-EC
2.2 5.5 3.0 6.9 3G3MX2-A4022-E 3G3MX2-A4022-P-E 3G3MX2-D4022-EC
3.0 7.2 4.0 8.8 3G3MX2-A4030-E 3G3MX2-A4030-P-E 3G3MX2-D4030-EC
4.0 9.2 5.5 11.1 3G3MX2-A4040-E 3G3MX2-A4040-P-E 3G3MX2-D4040-EC
5.5 14.8 7.5 17.5 3G3MX2-A4055-E - 3G3MX2-D4055-EC
7.5 18.0 11 23.0 3G3MX2-A4075-E - 3G3MX2-D4075-EC
11 24.0 15 31.0 3G3MX2-A4110-E - 3G3MX2-D4110-EC
15 31.0 18.5 38.0 3G3MX2-A4150-E - 3G3MX2-D4150-EC
A Input AC reactors
Inverter AC Reactor
Voltage Model 3G3MX2-@ Reference
AB002 / AB004 AX-RAI02000070-DE
AB007 AX-RAI01700140-DE
1-Phase 200 VAC
AB015 AX-RAI01200200-DE
AB022 AX-RAI00630240-DE
A2002 / A2004 / A2007 AX-RAI02800080-DE
A2015 / A2022 / A2037 AX-RAI00880200-DE
3-Phase 200 VAC
A2055 / A2075 AX-RAI00350335-DE
A2110 / A2150 AX-RAI00180670-DE
A4004 / A4007 / A4015 AX-RAI07700050-DE
A4022 / A4030 / A4040 AX-RAI03500100-DE
3-Phase 400 VAC
A4055 / A4075 AX-RAI01300170-DE
A4110 / A4150 AX-RAI00740335-DE
A DC reactors
200V 1-phase 200V 3-phase 400V 3-phase
Inverter DC Reactor Inverter DC Reactor Inverter DC Reactor
3G3MX2-AB001 AX-RC10700032-DE 3G3MX2-A2001 AX-RC21400016-DE 3G3MX2-A4004 AX-RC43000020-DE
3G3MX2-AB002 3G3MX2-A2002 3G3MX2-A4007 AX-RC27000030-DE
3G3MX2-AB004 AX-RC06750061-DE 3G3MX2-A2004 AX-RC10700032-DE 3G3MX2-A4015 AX-RC14000047-DE
3G3MX2-AB007 AX-RC03510093-DE 3G3MX2-A2007 AX-RC06750061-DE 3G3MX2-A4022 AX-RC10100069-DE
3G3MX2-AB015 AX-RC02510138-DE 3G3MX2-A2015 AX-RC03510093-DE 3G3MX2-A4030 AX-RC08250093-DE
3G3MX2-AB022 AX-RC01600223-DE 3G3MX2-A2022 AX-RC02510138-DE 3G3MX2-A4040 AX-RC06400116-DE
3G3MX2-A2037 AX-RC01600223-DE 3G3MX2-A4055 AX-RC04410167-DE
3G3MX2-A2055 AX-RC01110309-DE 3G3MX2-A4075 AX-RC03350219-DE
– 3G3MX2-A2075 AX-RC00840437-DE 3G3MX2-A4110 AX-RC02330307-DE
3G3MX2-A2110 AX-RC00590614-DE 3G3MX2-A4150 AX-RC01750430-DE
3G3MX2-A2150 AX-RC00440859-DE –
B Accessories
Types Model Description Functions
AX-OP05-E LCD remote operator 5 Line LCD remote operator with copy function, cable length max. 3m.
operator
3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator
Digital
3G3AX-OP01 LED remote operator LED remote operator, cable length max. 3m
4X-KITMINI Mounting kit for LED operator Mounting kit for LED operator on panel
3G3AX-OP05-H-E Operator holder Holder to put the AX-OP05-E inside of the cabinet
Accessories
Cat. No. SysCat_I113E-EN-05 In the interest of product improvement, specifications are subject to change without notice.
AX-
Drives, reactance 5,5kW 200V 22A AC output 1,15mH 319459 Buy on EAN
RAO01150220-DE
AX-REM00K6035-
Drives, Brake Resistance 600W 35ohm protected 324023 Buy on EAN
IE
AX-REM00K9020-
Drives, Brake Resistance 900W 20ohm protected 324024 Buy on EAN
IE
AX-REM00K9017-
Drives, Brake Resistance 900W 17ohm protected 324027 Buy on EAN
IE
AX-RC43000020-
Frequency converters, DC reactor 43mH 2A 400V 319455 Buy on EAN
DE
AX-RC27000030-
Frequency converters, DC reactor 27mH 3A 400V 319454 Buy on EAN
DE
AX-RC14000047-
Drives, 400V DC reactor 4,7a 14mH 319452 Buy on EAN
DE
AX-REM00K1400-
Drives, Brake Resistance 400ohm protected 190W 324010 Buy on EAN
IE
AX-RAI03500100-
Drives, 400V AC reactance 2,2-4kW 10A 3,5mH 319004 Buy on EAN
DE
AX-RAI00180670-
Drives, 11-15kW 200V 67A AC reactance 0,18mH 319008 Buy on EAN
DE
AX-RAI02800080-
Drives, 200V AC reactance 0,2-1,5kW 8A 2,8mH 319000 Buy on EAN
DE
AX-RAI00350335-
Drives, 200V AC reactance 5,5-7,5kW 33,5A 0,35mH 319002 Buy on EAN
DE
AX-RAI07700050-
Drives, 400V AC reactance 0,4-1,5kW 5A 7,7mH 319003 Buy on EAN
DE
AX-RAI00880200-
Drives, 200V AC reactance 2,2-4kW 20A 0,88mH 319006 Buy on EAN
DE
AX-REM00K2120-
Drives, Brake Resistance 120ohm protected 200W 324017 Buy on EAN
IE
AX-REM00K5120-
Drives, Brake Resistance 120ohm protected 500W 324016 Buy on EAN
IE
AX-REM00K2200-
Drives, Brake Resistance 200ohm protected 200W 324015 Buy on EAN
IE
AX-REM00K2070-
Drives, Brake Resistance 200W 70ohm protected 324012 Buy on EAN
IE
AX-REM00K9070-
Drives, Brake Resistance 900W 70ohm protected 324019 Buy on EAN
IE
AX-REM00K6100-
Drives, Brake Resistance 100ohm protected 600W 324018 Buy on EAN
IE
AX-
Drives, reactance AC 200V 1.5kW 7.5A Output 4,1mH 319465 Buy on EAN
RAO04100075-DE
AX-REM00K4035-
Drives, Brake Resistance 400W 35ohm protected 324014 Buy on EAN
IE
AX-REM00K4075-
Drives, Brake Resistance 400W 75ohm protected 324013 Buy on EAN
IE
Frequency converters, lift console accessory 3G3RX 356399 3G3AX-OP05-H-E Buy on EAN