ADR Calculator v1.22
ADR Calculator v1.22
CPQ Calculations
Storage array: 5500
Node Pairs: 1
Total: 656.9
0.0 TiB
0.0 TiB
0.0 TiB 100.0 TiB 200.0 TiB 300.0 TiB 400.0 TiB
INTERNAL USE ONLY Version 1.22
1
5%
Capacity Summary
Over- Total
Provisioned Reverse Calc. Non-ADR Effective
Capacity of ADR Portion Capacity
71.7 1104.6 + 0.0 = 1104.6 Total Desired Capacity 984.0 TiB
Configured Capacity (CPQ) 656.9 TiB
Total Effective Capacity 1,104.6 TiB
71.7 1,104.6 1,104.6
ADR Usable
Non-ADR Usable
ADR Overhead
HDT Overhead
Pool Buffer
Reduction; 398.8
TiB; 41%
ADR Calculations #1
Capacity for ADR
Lowest tier: % not idle for 24 hours if mult. Tiers
Desired Effective Capacity
Usable before overhead
ADR Overhead
ADR Subtotal
Non-ADR Calculation
Capacity for non-ADR
Lowest tier: % not idle for 24 hours if mult. Tiers
Non-ADR Subtotal
Subtotal
HDT Calculations
Ingest Tier: Initial I/O Buffer
Relocation Buffer
HDT Overhead
Subtotal
ADR Calculations #2
Lowest Tier: Pool free capacity
V 984.0 TiB
W 5%
X 0.0 TiB
Y 2 :1
Z 1
P 0% % to use:
Tier 1 2 3
A 100% 0% 0%
1
This field allows the user to indicate a buffer of free space to avoid the pool filling up completely. This number is based on the
understanding of how quickly the pool might fill up.
This field indicates which HDT tier will receive any new write data. A certain percentage of space is reserved for this data and
capacity being requested.
The maximum recommended ADR effective capacity is based on the cache of the system and the number of node pairs. This n
recommendation and is based on the ability of the system to avoid any cache contention. It is not meant to indicate a limit of
capacity that can be handled by the system.
ADR can be enabled at the LUN level. Thus, in an HDP/HDT pool, the user can provision some LUNs with ADR and some witho
to indicate the portion of the pool that will have LUNs with ADR enabled.
ADR only occurs on the lowest tier. If there is only one tier, then ADR (compression & dedupe) occurs inline (for most cases) a
immediately. If there are multiple tiers (i.e., HDT pool), then ADR is only calculated for the lowest tier capacity. Data that is re
lowest tier by HDT will be deduplicated once the 24 hour timer has completed. If data is accessed, it is moved back to a highe
immediately.
2% of the capacity is reserved by HDT for moving data between tiers. If there is only 1 tier, then this number is not relevant an
zero.
A percentage of capacity is reserved for new data (ingest writes). In flash tiers, there is no need for this buffer, however, lowe
approximately 8% reserved to handle the time delay between receiving the data and the time to move the data to the approp
movement is required).
3% of the pool capacity needs to be reserved for ADR metdata, a heavily accessed data area. Thus, this area is found in the hi
flash. 7% "garbage" area needs to be reserved in the tier in which the new writes are received (ingest write tier).
Reverse ADR Calculations
Tier
From forward calculations
From RAID groups capacity
From RAID groups capacity
Percentage of capacity per tier
ADR Ratio for the tier
ADR Overhead perc
Non-ADR Capacity for the tier
Non-Idle percentage
ADR Calculations #1
Capacity for ADR
Lowest tier: % not idle for 24 hours if mult. Tiers
Desired Effective Capacity
Usable before overhead
ADR Overhead
ADR Subtotal
Non-ADR Calculation
Capacity for non-ADR
Lowest tier: % not idle for 24 hours if mult. Tiers
Non-ADR Subtotal
Subtotal
HDT Calculations
Ingest Tier: Initial I/O Buffer
Relocation Buffer
HDT Overhead
Subtotal
ADR Calculations #2
Lowest Tier: Pool free capacity
Chart Display
ADR Usable
Non-ADR Usable
ADR Overhead
HDT Overhead
Pool Buffer
1 2 3
585.22105263
656.929636
T 656.929636
a = T / (all T) 100.00% 0.00% 0.00%
y = if lowest tier, ADRRatio, 1 2 1 1
f = (3% if highest tier)+(7% if ingest tier) 7% 0% 0%
x = A * Non-ADR Capacity 0 0 0
p = if lowest tier, %, 0 0% 0% 0%
z = if tier 1, 0, .08 0% 0% 0%
w = pool space 5% 5% 5%
Final: 1104.5719543 0 0
Non-ADR 0 0
Total: 1104.5719543 0 0
Grand total: 1104.5719543 1104.5719543 1104.5719543
B = (V-X) * A 1104.5719543 0 0
C = if lowest tier, B * P 0 0 0
D=B-C 1104.5719543 0 0
E = D / Y if Tier is lowest 552.28597717 0 0
F = [(if highest, 3%) + (if ingest tier, 7%)] * B 71.797177032 0 0
G=E+F 624.0831542 0 0
H=X*A 0 0 0
C 0 0 0
I=H+C 0 0 0
J=G+I 624.0831542 0 0
O = (N / (1-W)) - N 32.8464818 0 0
T=N+O 656.929636 0 0
Tier 1
552.3 TiB 0.0 TiB 0.0 TiB 552.28598
0.0 TiB 0.0 TiB 0.0 TiB 0
71.8 TiB 0.0 TiB 0.0 TiB 71.797177
0.0 TiB 0.0 TiB 0.0 TiB 0
32.8 TiB 0.0 TiB 0.0 TiB 32.846482
656.929636 0
Reference Tables
Series VSP 5000
RAID Key D
Disk Group VSP 5K-F
Max CBXs 3
CBXs: 1
NodePairList
1 1
2 2
3 3
Max_ADR_Capac 2122.3
DriveListTable
AvailDriveList
Disks Available Part Description Part Number Drive Model Capacity Tag Media Type Shelf Type
1 7TB FMD HD 7RTB-FP 7R0FP 7TB FMD FBX
2 14TB FMD HD 14RTB-FP 14RFP 14TB FMD FBX
3 960GB SSD 960GB-MGM 960MGM 960GB SSD SBX
4 1.9TB SSD 1T9TB-MGM 1T9MGM 1.9TB SSD SBX
5 3.8TB SSD 3R8TB-MGM 3R8MGM 3.8TB SSD SBX
6 7.6TB SSD 7R6TB-MGM 7R6MGM 7.6TB SSD SBX
7 15TB SSD 15R3TB-MGM 15RMGM 15TB SSD SBX
8 30TB SSD 30TB-MGM 30RMGM 30TB SSD SBX
9 1.9TB NVMe 1R9TB-RVM 1R9RVM 1.9TB NVMe NBX
10 3.8TB NVMe 3R8TB-RVM 3R8RVM 3.8TB NVMe NBX
11 7.6TB NVMe 7R6TB-RVM 7R6RVM 7.6TB NVMe NBX
12 15TB NVMe 15R3TB-RVM 15RRVM 15TB NVMe NBX
13 30TB NVMe 30TB-RVM 30RRVM 30TB NVMe NBX
14 375GB SCM 375GB-YVM 375YVM 375GB SCM NBX
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
7RTB-FP 7R0FP
14RTB-FP 14RFP
960GB-MGM 960MGM
1T9TB-MGM 1T9MGM
3R8TB-MGM 3R8MGM
7R6TB-MGM 7R6MGM
15R3TB-MGM 15RMGM
30TB-MGM 30RMGM
2R4TB-JGM 2R4JGM
14RTB-H9M 14RH9M
Part Number Drive Mode
7RTB-FP 7R0FP
14RTB-FP 14RFP
960GB-MGM 960MGM
1T9TB-MGM 1T9MGM
3R8TB-MGM 3R8MGM
7R6TB-MGM 7R6MGM
15R3TB-MGM 15RMGM
30TB-MGM 30RMGM
1R9TB-RVM 1R9RVM
3R8TB-RVM 3R8RVM
7R6TB-RVM 7R6RVM
15R3TB-RVM 15RRVM
30TB-RVM 30RRVM
375GB-YVM 375YVM
2R4TB-JGM 2R4JGM
14RTB-H9M 14RH9M
HDW2-F800-300KCM S5C-K300SS
HDW2-F800-600KGM R5C-K600SS
HDW2-F800-600JCM R5D-J600SS
HDW2-F800-1R2JCM S5K-J1R2SS
HDW2-F800-1R2J7M S5K-J1R2SS
HDW2-F800-1R8JGM S5K-J1R8SS
HDW2-F800-1R8J8M S5K-J1R8SS
HDW2-F800-2R4JGM S5K-J2R4SS
HDW2-F800-2R4J8M S5K-J2R4SS
HDW2-F800-4R0H3M S2E-H4R0SS
HDW2-F800-4R0H4M S2E-H4R0SS
HDW2-F800-6R0H9M S2F-H6R0SS
HDW2-F800-6R0HLM S2F-H6R0SS
HDW2-F800-10RHLM R2H-H10RS
HDW2-F800-200MEM B5B-M200S
HDW2-F800-400MEM B5B-M400S
HDW2-F800-400M8M B5B-M400S
HDW2-F800-480MGM B5F-M480S
HDW2-F800-960MGM B5F-M960S
HDW2-F800-1R9MEM B5D-M1R9S
HDW2-F800-3R8MGM R5E-M3R8S
HDW2-F800-7R6MGM R5E-M7R6S
HDW2-F800-1R6FM H1A-P1R6S
HDW2-F800-3R2FM H1B-P3R2SS
HDW2-F800-1R6FN HAE-Q1R6S
HDW2-F800-3R2FN HAE-Q3R2S
HDW2-F800-6R4FN HAE-Q6R4S
HDW2-F810I-7R0FP HAF-Q6R4S
HDW2-F810I-14RFP HAF-Q13RS
HDW-F800-300KCM S5C-K300SS
HDW-F800-600KGM R5C-K600SS
HDW-F800-600JCM R5D-J600SS
HDW-F800-1R2JCM S5K-J1R2SS
HDW-F800-1R2J7M S5K-J1R2SS
HDW-F800-1R8JGM S5K-J1R8SS
HDW-F800-1R8J8M S5K-J1R8SS
HDW-F800-2R4JGM S5K-J2R4SS
HDW-F800-2R4J8M S5K-J2R4SS
HDW-F800-4R0H3M S2E-H4R0SS
HDW-F800-4R0H4M S2E-H4R0SS
HDW-F800-6R0H9M S2F-H6R0SS
HDW-F800-6R0HLM S2F-H6R0SS
HDW-F800-10RHLM R2H-H10RS
HDW-F800-200MEM B5B-M200S
HDW-F800-400MEM B5B-M400S
HDW-F800-400M5M B5B-M400S
HDW-F800-480MGM B5F-M480S
HDW-F800-960MGM B5F-M960S
HDW-F800-1R9MEM B5D-M1R9S
HDW-F800-3R8MGM R5E-M3R8S
HDW-F800-7R6MGM R5E-M7R6S
HDW-F800-1R6FM H1A-P1R6S
HDW-F800-3R2FM H1B-P3R2SS
HDW-F800-1R6FN HAE-Q1R6S
HDW-F800-3R2FN HAE-Q3R2S
HDW-F800-6R4FN HAE-Q6R4S
HDW-F810I-7R0FP HAF-Q6R4S
HDW-F810I-14RFP HAF-Q13RS
HDW-F800-300KCM S5C-K300SS
HDW-F800-600KGM R5C-K600SS
HDW-F800-600JCM R5D-J600SS
HDW-F800-1R2JCM S5K-J1R2SS
HDW-F800-1R2J7M S5K-J1R2SS
HDW-F800-1R8JGM S5K-J1R8SS
HDW-F800-1R8J8M S5K-J1R8SS
HDW-F800-2R4JGM S5K-J2R4SS
HDW-F800-2R4J8M S5K-J2R4SS
HDW-F800-4R0H3M S2E-H4R0SS
HDW-F800-4R0H4M S2E-H4R0SS
HDW-F800-6R0H9M S2F-H6R0SS
HDW-F800-6R0HLM S2F-H6R0SS
HDW-F800-10RHLM R2H-H10RS
HDW-F800-200MEM B5B-M200S
HDW-F800-400MEM B5B-M400S
HDW-F800-400M5M B5B-M400S
HDW-F800-960MGM B5F-M960S
HDW-F800-1R9MEM B5D-M1R9S
HDW-F800-3R8MGM R5E-M3R8S
HDW-F800-7R6MGM R5E-M7R6S
HDW-F800-1R6FM H1A-P1R6S
HDW-F800-3R2FM H1B-P3R2SS
HDW-F800-1R6FN HAE-Q1R6S
HDW-F800-3R2FN HAE-Q3R2S
HDW-F800-6R4FN HAE-Q6R4S
HDW-F810I-7R0FP HAF-Q6R4S
HDW-F810I-14RFP HAF-Q13RS
HDW-F800-1R6FN HAE-Q1R6S
HDW-F800-3R2FN HAE-Q3R2S
HDW-F800-6R4FN HAE-Q6R4S
HDW-F800-1R6FN HAE-Q1R6S
HDW-F800-3R2FN HAE-Q3R2S
HDW-F800-6R4FN HAE-Q6R4S
HDW-F810I-7R0FP HAF-Q6R4S
HDW-F810I-14RFP HAF-Q13RS
HDW-F800-1R9MEM B5D-M1R9S
HDW-F800-3R8MGM R5E-M3R8S
HDW-F800-7R6MGM R5E-M7R6S
HDW2-F850-480MGM 480MGM
DW2-F850-1R9MEM 1T9MGM
HDW2-F850-3R8MGM 3R8MGM
HDW2-F850-7R6MGM 7R6MGM
DW2-F850-15RMGM 15RMGM
DW2-F850-30RMGM 30RMGM
DW2-F850-600JCM 600JCM
DW2-F850-1R2JCM 1R2JCM
DW2-F850-1R2J7M 1R2JCM
DW2-F850-2R4JGM 2R4JGM
DW2-F850-2R4J8M 2R4JGM
DW2-F850-6R0H9M 6R0H9M
DW2-F850-6R0HLM 6R0H9M
DW2-F850-10RH9M 10RH9M
DW2-F850-10RHLM 10RH9M
DW2-F850-14RH9M 14RH9M
DW2-F850-14RHLM 14RH9M
HDW2-F850-3R2FN 3R2FN
HDW2-F850-7R0FP 7R0FP
HDW2-F850-14RFP 14RFP
HDW2-F850-480MGM 480MGM
HDW2-F850-1R9MEM 1T9MGM
HDW2-F850-3R8MGM 3R8MGM
HDW2-F850-7R6MGM 7R6MGM
DW2-F850-15RMGM 15RMGM
DW2-F850-30RMGM 30RMGM
DW2-F850-600JCM 600JCM
DW2-F850-1R2JCM 1R2JCM
DW2-F850-1R2J7M 1R2JCM
DW2-F850-2R4JGM 2R4JGM
DW2-F850-2R4J8M 2R4JGM
DW2-F850-6R0H9M 6R0H9M
DW2-F850-6R0HLM 6R0H9M
DW2-F850-10RH9M 10RH9M
DW2-F850-10RHLM 10RH9M
DW2-F850-14RH9M 14RH9M
DW2-F850-14RHLM 14RH9M
HDW2-F850-3R2FN 3R2FN
HDW2-F850-7R0FP 7R0FP
HDW2-F850-14RFP 14RFP
HDW2-F850-1R9MEM 1T9MGM
HDW2-F850-3R8MGM 3R8MGM
HDW2-F850-7R6MGM 7R6MGM
DW-F850-15RMGM 15RMGM
DW-F850-30RMGM 30RMGM
HDW2-F850-600JCM 600JCM
HDW2-F850-1R2JCM 1R2JCM
HDW2-F850-1R2J7M 1R2JCM
HDW2-F850-2R4JGM 2R4JGM
HDW2-F850-2R4J8M 2R4JGM
HDW2-F850-6R0H9M 6R0H9M
HDW2-F850-6R0HLM 6R0H9M
HDW2-F850-10RH9M 10RH9M
HDW2-F850-10RHLM 10RH9M
DW-F850-14RH9M 14RH9M
DW-F850-14RHLM 14RH9M
Part Number Drive Mode
Ex90-1R9TB 1R9RVM
Ex90-3R8TB 3R8RVM
Ex90-7R6TB 7R6RVM
Ex90-15R3TB 15RRVM
Ex90-30TB 30RRVM
Shelf Type COG Index Power
FBX 0.31 0.026
FBX 0.62 0.026
SBX 0.09 0.007
SBX 0.09 0.0083
SBX 0.17 0.007
SBX 0.33 0.0083
SBX 0.65 0.0083
SBX 1.26 0.0083
NBX 0.13 0.02
NBX 0.18 0.02
NBX 0.36 0.02
NBX 0.71 0.02
NBX 1.36 0.02
NBX 0.41 0.02
5.5" 12
5.5" 12
2.5" 12
2.5" 0
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 6
3.5" 12
Size (UnuseInterface Speed
5.5" 12
5.5" 12
2.5" 12
2.5" 0
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 8
2.5" 8
2.5" 8
2.5" 8
2.5" 8
2.5" 8
2.5" 6
3.5" 12
2.5" 0
2.5" 0
2.5" 6
2.5" 0
2.5" 0
2.5" 6
2.5" 6
2.5" 6
2.5" 6
3.5" 0
3.5" 0
3.5" 12
3.5" 12
3.5" 12
2.5" 12
2.5" 12
3.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 6
2.5" 0
5.5" 6
5.5" 6
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
2.5" 0
2.5" 0
2.5" 6
2.5" 0
2.5" 0
2.5" 6
2.5" 6
2.5" 6
2.5" 6
3.5" 0
3.5" 0
3.5" 12
3.5" 12
3.5" 12
2.5" 12
2.5" 12
3.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 6
2.5" 0
5.5" 6
5.5" 6
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
2.5" 0
2.5" 0
2.5" 6
2.5" 0
2.5" 0
2.5" 6
2.5" 6
2.5" 6
2.5" 6
3.5" 0
3.5" 0
3.5" 12
3.5" 12
3.5" 12
2.5" 12
2.5" 12
3.5" 12
2.5" 12
2.5" 12
2.5" 6
2.5" 0
5.5" 6
5.5" 6
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
5.5" 12
2.5" 12
2.5" 6
2.5" 0
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 6
2.5" 6
2.5" 6
2.5" 6
2.5" 6
3.5" 12
3.5" 12
3.5" 12
3.5" 12
3.5" 12
3.5" 12
5.5" 12
5.5" 12
5.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 6
2.5" 6
2.5" 6
2.5" 6
2.5" 6
3.5" 12
3.5" 12
3.5" 12
3.5" 12
3.5" 12
3.5" 12
5.5" 12
5.5" 12
5.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 12
2.5" 6
2.5" 6
2.5" 6
2.5" 6
2.5" 6
3.5" 12
3.5" 12
3.5" 12
3.5" 12
3.5" 12
3.5" 12
Size (UnuseInterface Speed
2.5" 8
2.5" 8
2.5" 8
2.5" 8
2.5" 8
Maximum Drive/Shelf Calculator
ArrayTable Model Min BEDs Max BEDs Paths CTL Boxes Boxes Per PathDrives in Cont
G350-S 1 1 1 1 8 SFF
G350-L 1 1 1 1 8 LFF
G370-S 1 1 1 1 12 SFF
G370-L 1 1 1 1 12 LFF
G700 1 1 4 0 12
G900 1 2 4 0 6
G900-E 1 2 4 0 6
G200-S 1 1 1 1 8 SFF
G200-L 1 1 1 1 8 LFF
G400 1 1 2 0 8
G600 1 1 2 0 12
G800 1 2 4 0 6
G800-E 1 2 4 0 6
5100 1 1 4 0 8
5100H 1 1 4 0 8
5500 1 3 12 0 8
5500H 1 3 12 0 8
E590 1 1 1 NVMe
E790 1 1 1 NVMe
E990 1 2 0 NVMe
HUS110-S 1 1 11 SFF
HUS110-L 1 1 11 LFF
HUS130-S 2 1 11 SFF
HUS130-L 2 1 11 LFF
HUS150 4 0 11
HUS VM 1 3
VSP 1 2
G1000 1 2
G1000-U 1 2
G1500 1 2
F1500 1 2
Spin/SSD FMD
G200-S 264
G200-L 252
G400 480
G600 720
G800 1440
G350-S 264
G350-L 252
G370-S 384
G370-L 372
G700 1200
G900 1440
F350 192
F370 288
F700 864 432
F900 1152 576
RAID Level Selection
Index A B C D
1 RAID-10 2+2 RAID-10 1+1 RAID-10 2+2 RAID-10 2+2
2 RAID-10 4+4 RAID-10 2+2 RAID-10 4+4 RAID-10 4+4
3 RAID-5 3+1 RAID-10 3+3 RAID-5 3+1 RAID-5 3+1
4 RAID-5 6+1 RAID-10 4+4 RAID-5 7+1 RAID-5 7+1
5 RAID-5 7+1 RAID-10 5+5 RAID-6 6+2 RAID-6 6+2
6 RAID-6 6+2 RAID-10 6+6 RAID-6 14+2
7 RAID-6 12+2 RAID-10 7+7
8 RAID-6 14+2 RAID-10 8+8
9 RAID-5 2+1
10 RAID-5 3+1
11 RAID-5 4+1
12 RAID-5 5+1
13 RAID-5 6+1
14 RAID-5 7+1
15 RAID-5 8+1
16 RAID-5 9+1
17 RAID-5 10+1
18 RAID-5 11+1
19 RAID-5 12+1
20 RAID-5 13+1
21 RAID-5 14+1
22 RAID-5 15+1
23 RAID-6 2+2
24 RAID-6 3+2
25 RAID-6 4+2
26 RAID-6 5+2
27 RAID-6 6+2
28 RAID-6 7+2
29 RAID-6 8+2
30 RAID-6 9+2
31 RAID-6 10+2
32 RAID-6 11+2
33 RAID-6 12+2
34 RAID-6 13+2
35 RAID-6 14+2
36 RAID-6 15+2
37 RAID-6 16+2
38 RAID-6 17+2
39 RAID-6 18+2
40 RAID-6 19+2
41 RAID-6 20+2
42 RAID-6 21+2
43 RAID-6 22+2
44 RAID-6 23+2
45 RAID-6 24+2
46 RAID-6 25+2
47 RAID-6 26+2
48 RAID-6 27+2
49 RAID-6 28+2
Col Indx: 7
E F Available Selections
RAID-10 2+2 RAID-10 2+2 RAID-10 2+2 RAID-10 2+2 RAID-10
RAID-10 4+4 RAID-10 4+4 RAID-10 4+4 RAID-10 4+4 RAID-10
RAID-5 3+1 RAID-5 3+1 RAID-5 3+1 RAID-5 3+1 RAID-5
RAID-5 4+1 RAID-5 7+1 RAID-5 7+1 RAID-5 7+1 RAID-5
RAID-5 6+1 RAID-6 6+2 RAID-6 6+2 RAID-6 6+2 RAID-6
RAID-5 7+1 RAID-6 14+2 RAID-6 14+2 RAID-6
RAID-6 6+2 0 0
RAID-6 12+2 0 0
RAID-6 14+2 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
AvailRAIDLevels
2+2 RAID-10 2+2
4+4 RAID-10 4+4
3+1 RAID-5 3+1
7+1 RAID-5 7+1
6+2 RAID-6 6+2
14+2 RAID-6 14+2
Capacity key RAID-10 2+2 RAID-10 4+4 RAID-5 3+1 RAID-5 6+1
VSP 5000-15TB-SSD 29391580672 29391580672 29391580672
VSP 5000-1.9TB-SSD 3692306432 3692306432 3692306432
VSP 5000-30TB-SSD 58781068800 58781068800 58781068800
VSP 5000-3.8TB-SSD 7384614912 7384614912 7384612864
VSP 5000-7TB-FMD 13743892480 13743892480 13743887360
VSP 5000-14TB-FMD 27487788544 27487788544 27487788544
VSP 5000-7.6TB-SSD 14769228800 14769228800 14769226752
VSP 5000-960GB-SSD 1846153216 1846153216 1846153216
VSP 5000-1.9TB-NVMe 3692306432 3692306432 3692306432
VSP 5000-3.8TB-NVMe 7384614912 7384614912 7384615424
VSP 5000-7.6TB-NVMe 14769228800 14769228800 14769230848
VSP 5000-15TB-NVMe 29391580672 29391580672 29391580672
VSP 5000-30TB-NVMe 58781068800 58781068800 58781068800
VSP 5000-375GB-SCM 732580864 732580864 732580864
VSP 5000-2.4TB-SAS 4503072768 4503072768 4503072768
VSP 5000-10TB-NL-SAS 19121793024 19121793024 19121789952
VSP 5000-14TB-NL-SAS 26770512916 26770512916 26770512916
RAID-5 7+1 RAID-6 6+2 RAID-6 12+2 RAID-6 14+2
29391580672 29391580672 29391580672
3692303360 3692307456 3692306432
58781068800 58781068800 58781068800
7384614912 7384612864 7384609792
13743882240 13743882240 13743881216
27487788544 27487788544 27487788544
14769225728 14769199104 14769219584
1846152192 1846149120 1846153216
3692303360 3692307456 3692306432
7384614912 7384612864 7384609792
14769225728 14769199104 14769219584
29391580672 29391580672 29391580672
58781068800 58781068800 58781068800
732580864 732580864 732580864
4503070720 4503070720 4503070720
19121786880 19121786880 19121780736
26770512916 26770512916 26770512916