4/20/2021 BXUV.

N505 - Fire-resistance Ratings - ANSI/UL 263 | UL Product iQ

BXUV.N505 - Fire-resistance Ratings - ANSI/UL 263

Design/System/Construction/Assembly Usage Disclaimer


Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and
use of UL Certified products, equipment, system, devices, and materials.
Authorities Having Jurisdiction should be consulted before construction.
Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for
compliance with applicable requirements. The published information cannot always address every construction nuance
encountered in the field.
When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product
manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for
each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials
and alternate methods of construction.
Only products which bear UL's Mark are considered Certified.

BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United


States
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States
Design Criteria and Allowable Variances

See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
Design Criteria and Allowable Variances

Design No. N505


October 06, 2020

Restrained Beam Rating — 3 Hr.


Unrestrained Beam Rating — 2 Hr.
This design was evaluated using a load design method other than the Limit States
Design Method (e.g., Working Stress Design Method). For jurisdictions employing
the Limit States Design Method, such as Canada, a load restriction factor shall be
used — See Guide BXUV or BXUV7

* Indicates such products shall bear the UL or cUL Certification Mark for
jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

https://iq.ulprospector.com/en/profile?e=14388 1/4
4/20/2021 BXUV.N505 - Fire-resistance Ratings - ANSI/UL 263 | UL Product iQ

Steel Beam — Min size, a W8 x 24 with outside dimensions of 7-7/8 x 6-1/2 in. with a flange thickness of 3/8 in., a web
thickness of 1/4 in., and a cross-sectional area of 7.06 sq in.
1. Normal Weight Concrete — 151 pcf.

2. Steel Floor and Form Units* — 1-1/2 in. fluted type, welded to beam.

3. Drill Screw — No. 8-18 by 1/2 in. long Phillips panhead drill screws, self-drilling and tapping, made of case-hardened steel.

4. Runner Channel — Fabricated from 25 MSG galv steel, 1-11/16 in. deep with 1-in. legs. Fastened to steel deck with drill
screws, 12 in. O.C.

5. Bracket — Same material as runner channel or 24 MSG galv steel angle with 1 and 2-in. legs, and fastened to runner
channels with drill screws (Item 3). Brackets spaced 24 in. O.C.

6. Corner Angle — No. 24 MSG galv steel with 1 and 2-in. legs, fastened to brackets with drill screws (Items 3).

7. Gypsum Board* — 5/8 in. thick. Inner layer fastened with 1 in. long 0.150 in. diam screws and spaced 16 in. OC. Middle
layer attached with 1-5/8 in. long 0.150 in. diam screws spaced 12 in. OC. Outer layer attached with 2-1/4 in. long, 0.150 in.
diam screws spaced 8 in. OC. At least one screw at mid-depth of brackets in each layer. Screws are self-drilling and self-
tapping Phillips head made of case-hardened steel.
AMERICAN GYPSUM CO — Types AG-C, AGX-1, LightRoc.

https://iq.ulprospector.com/en/profile?e=14388 2/4
4/20/2021 BXUV.N505 - Fire-resistance Ratings - ANSI/UL 263 | UL Product iQ

BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO — Type DBX-1.

CABOT MANUFACTURING ULC — Type X, Type Blueglass Exterior Sheathing

CERTAINTEED GYPSUM INC — Types EGRG, GlasRoc, GlasRoc-2, Type C, Type X or Type X-1.

CGC INC — Type C, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRX, ULIX.

CERTAINTEED GYPSUM INC — Types LGFC6A, LGFC-C/A.

GEORGIA-PACIFIC GYPSUM L L C — Types 5, 9, C, DGG, DAP, DAPC, DD, DA, DS, GPFS6, TG-C, GreenGlass Type X, Type X, Veneer Plaster
Base - Type X, Water Rated - Type X, Sheathing - Type X, Soffit - Type X, Type LWX, Veneer Plaster Base-Type LWX, Water Rated-Type LWX,
Sheathing Type-LWX, Soffit-Type LWX, Type LW2X, Veneer Plaster Base - Type LW2X, Water Rated - Type LW2X, Sheathing - Type LW2X,
Soffit - Type LW2X.

NATIONAL GYPSUM CO — Types FSK, FSK-C, FSL, FSMR-C, FSW, FSW-C, FSW-G, FSW-3, FSW-6, FSW-8.

NATIONAL GYPSUM CO — Riyadh, Saudi Arabia — Type FR, or WR.

PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type C, PG-9, PG-11, PG-C, PGS-WRS or PGI.

PANEL REY S A — Type PRC

SIAM GYPSUM INDUSTRY (SARABURI) CO LTD — Type EX-1

THAI GYPSUM PRODUCTS PCL — Type C or Type X

THE SIAM GYPSUM INDUSTRY (SONGKHLA) CO — Types C and SCX

UNITED STATES GYPSUM CO — Type C, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRX, ULIX.

USG BORAL DRYWALL SFZ LLC — Types C, SCX

USG MEXICO S A DE C V — Type C, IP-X1, IP-X2, IPC-AR, SCX, SHX or WRX.

8. Wire Netting — No. 20 SWG hexagonal mesh with 20 SWG longitudinal stiffener at third points of 3-ft wide roll. Installed
on bottom, bent up approx 1-1/2 in. on each side, and secured to sides with same screws used to hold middle layer or
wallboard.

9. Corner Bead — Fabricated from 20 MSG galv steel to form an angle with 1-1/4 in. legs. Legs perforated with 1/4 in. diam
holes approx 1 in. OC. Attached to wallboard with 4d nails approx 12 in. OC in both legs.

10. Joint Compound — 1/32 in. thick on bottom and sides of wallboard from corner beads and feathered out. Paper tape
embedded in joint compound over joints with edges of compound feathered out. Nom 3/32 in. thick gypsum veneer plastic
may be applied to the entire surface of Classified veneer baseboard. Joints reinforced.

11. Protective Material — Spray-Applied Fire Resistive Materials* — Spray applied contour of the units to a thickness of
7/8 in.

https://iq.ulprospector.com/en/profile?e=14388 3/4
4/20/2021 BXUV.N505 - Fire-resistance Ratings - ANSI/UL 263 | UL Product iQ
See Spray-Applied Fire Resistive Materials (CHPX) category for names of manufacturers.

12. Alternate Construction - Steel Framing Members-* — As an alternate to Items 3, 4, 5, 6 and 8 steel clips attached to
both sides of beam flanges 2 ft OC and at ends of beam. Inner layer of gypsum board fastened to steel clips with 1-1/4 in.
long Type S drywall screws. Middle layer fastened to steel clips with 2 in. long Type S drywall screws. 2 in. by 2 in. 25 MSG
angle fastened to clips on bottom portion of assembly with 2 in. long Type S drywall screws. Outer layer of gypsum board
fastened to angle and clips with 2-1/4 in. long Type S drywall screws, spaced 2 ft OC. Screws are self-drilling and self-tapping
Phillips head made of case-hardened steel.
JOHN WAGNER ASSOCIATES INC, DBA GRABBER — Type CB Clip.

* Indicates such products shall bear the UL or cUL Certification Mark for
jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
Last Updated on 2020-10-06

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading
manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission
from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following
format: "© 2021 UL LLC"

https://iq.ulprospector.com/en/profile?e=14388 4/4

You might also like