Chamber Acceptance Test

1 Shielding Effectiveness (SE)

2 Normalised Site Attenuation (NSA)

3 Site VSWR (Svswr)

4 Field Uniformity (FU)

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Shielding Effectiveness / EN50147-1
Frequency Standard Performance High Performance

H-Field
10 kHz 40 dB  60 dB
100 kHz 60 dB  80 dB
1 MHz 80 dB  100 dB

E-Field
Up to 1 GHz 100 dB  100 dB
10 GHz 80 dB  90 dB
18 GHz 60 dB  70 dB
Magnetic
Shielding effectiveness Electric
Microwave
140
120
100
80
60
40
20
0

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Normalised Site Attenuation / CISPR 16-1-4
CISPR16-1-4 Edition 2.1 (Jan. 2008) and
Standard
other similar standards
Frequency range Chamber is fully compliant from 30 MHz to 1 GHz

Measurement distance 10.0m from antenna reference point to EMI test volume

Height of transmitting (Tx) antenna Horizontal : 1.0m, 2.0m / Vertical : 1.0m, 1.5m

Height of receiving (Rx) antenna Horizontal and vertical polarizations: scan from 1.0 to 4.0m

Polarization Horizontal and vertical

Tx antenna to be located in four positions


Measured position of Tx antenna (centre, front, left and right)

Test volume (cylinder) Diameter : 3.0 m / Height : 3.0 m

Remark Test with metallic ground plane (no absorbers on the floor)

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Site VSWR / CISPR 16-1-4

Standard CISPR16-1-4 Edition 2.1 (Jan. 2008) and other similar standards

Frequency range Chamber is fully compliant from 1 GHz to 18 GHz

Measurement distance 3.0m from antenna reference point to EMI test volume

Height of transmitting (Tx) antenna 1.36m & 3.36m

Height of receiving (Rx) antenna 1.36m & 3.36m

Polarization Horizontal and vertical

Tx antenna to be located in four positions (centre, front, left and


Measured position of Tx antenna right)

Test volume (cylinder) Diameter : 3.0m / Height : 3.0m (from 0.36m to 3.36m)

Test with HYFRAL APM broadband pyramidal absorbers (20x


Remark APM66 + 56x APM30) on the floor and turntable

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Field Uniformity / EN 61000-4-3
Standard IEC 61000-4-3:2006

Frequency range Chamber is fully compliant from 26 MHz to 18 GHz

Measurement distance 3 m from antenna tip to uniform field area

Biconical + LPDA or broadband BiLog antenna (not included in our


Field Generation Antenna
quotation)

Broadband isotropic probe, 16 positions, measured area of 1,5 x 1,5 m,


Receiving antenna
located 0,8 m – 2,3 m over the floor

Polarization Horizontal and vertical

Test with pyramidal absorbers the floor between field generation antenna
Remark
and field uniformity plan area (≈ 6 m²)

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


辐射骚扰测试 (Radiated Emission Test):电波暗室
Radiated Emission (RE) Test Setup: Semi-Anechoic Chamber (SAC)

Pyramidal Absorbers
吸波材料
测试距离:1m、3m、10m
Test Distance

Polarisations (H/V) EMI Antenna


天线极化 测量天线
0°; 90°
EUT

Scan Height
高度扫描
1 – 4m 方位变化
0°- 360°
连接到接收机 Rotation
Connecting from
Test Receiver 反射地平面 传台 Power Supply
Reflection Ground Turntable

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


辐射抗干扰测试 (Radiated Immunity Test):电波暗室
Radiated Immunity (RI) Test Setup: Full-Anechoic Chamber (FAC)

Pyramidal Absorbers
吸波材料
测试距离:1m、3m、10m
Test Distance

Polarisations (H/V) EMI Antenna


天线极化 测量天线
0°; 90°
EUT

地面吸波材料
Floor Absorbers
连接到接收机
Connecting from
Test Receiver Power Supply

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Types of Chambers

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Host Building Requirements
The shielded room must be installed on a smooth plane ground, free of
defects and preserved from any dampness risk.

The requested planarity for the floor must follow the requirements of the
DIN18202 standard: < 1cm / 1m, without exceeding 3cm / 10m.

The floor must be able to withstand the following loads :


- A load of 6 tons under each of the 6 pillars of the structural steel frame
(approximate 30 x 30 cm² surface),
- A linear load of 1000 kg per linear meter all around the perimeter of the
chamber,
- A surface load of 100 kg per square meter for the floor of the chamber.

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Floor Requirement - Turntable
A pit (approximate minimum dimensions 3,5 m x 3,5 m x -1 m) is dug in the host
building floor for easy turntable installation.

This pit will be shielded using welded copper foil which is linked on its periphery
to the floor shielding panels using specific bolted frames.

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Turntable
- Heavy duty, electrically powered, metal top
- Diameter : 1.5m, 2m, 3m, 3.5m, 4m., 5m, 8m etc.
- Max load capacity : 500kg, 1t, 1.5t, 2t, 3t etc.
- Including power supply cable and fibre optics
- Position range : 0° / 360°
- Position accuracy : < 1°
- Electrically driven by brushless servo-motor, through fibre optics
- Remote controllable

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Self Supporting Structures

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Shielded Doors

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Hybrid Absorbers

Plastic Paint - Colours Normal Aqueous Paint

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Properties of Plastic Paint Absorbers

1. The paint coated absorbers are softer than usual.


2. After compression, the absorber shape & materials remain intact – no broken pieces.
3. Chambers will have bright looks and absorbers are long Lasting.
4. The coated paint ensures the carbon powder does not fall out, clean environment.
5. RF performance shall remain constant for many years – High Performance Warranty

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Aesthetic Effects

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Chamber Accessories

CCTV Filters
Antenna Mast

Ferrite Tiles Honeycomb Feedthrough Panels

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Typical 10m Chamber Dimensions

External dimensions Internal Dimensions


Total overall dimensions.* From external shield to shield. From absorbers tips to tips
Length 20000 mm. 19530 mm. 18500 mm.
Width 13800 mm. 12440 mm. 11260 mm.
Height 9700 mm. 8760** mm. 7945** mm.
* approximate dimensions including support steel frame and stiffeners
** assuming a 200mm high raised floor

All dimensions and location of various elements (doors, filters, wall panels,
etc…) can be discussed, modified and finalized on a mutual agreement to
optimize the configuration of the rooms in the parent building and create a
laboratory with optimum ergonomics.

Typical 10m Drawings

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


Ferdinand Chandra: +62 818-0733-1341 [email protected]

PT.TRIDINAMIKA JAYA INSTRUMENT www.tridinamika.com


THANK YOUPT Tridinamika Jaya Instrument
Office : Jl. Boulevard Raya Blok BA3 No. 15 Gading Serpong – Tangerang 15810
Fax : 021 5467617 Telp : 021 54212399 – 54212402 – 5467618 - 54220925

Tridinamika Tridinamika Tridinamika Jaya Instrument TridinamikaTV tridinamika.com

You might also like