General Plumbing Notes & Specs
General Plumbing Notes & Specs
P1 CB1 CB1
150mmØ PVC DP
CB1
150mmØ PVC DP
CB1
GT
DS AV
DS DS DS
1. ALL PLUMBING WORKS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION
OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES, NATIONAL FIRE
50mmØ PVC WP
PROTECTION ASSOCIATION, THE FIRE CODE OF THE PHILIPPINES, NATIONAL KS
BUILDING CODE OF THE PHILIPPINES AND LOCAL REGULATION AND ORDINANCES.
KS
2. THE PLUMBING CONTRACTOR SHALL LOCATE AND DETERMINE THE ACTUAL
LOCATIONS OF EXISTING SANITARY FACILITIES TO COMFORM WITH THE
PROPOSED DESIGN. SV
150mmØ PVC DP
3. ALL PIPES SHALL BE INSTALLED AS INDICATED IN THE WORKING DRAWINGS.
ANY RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER TRADES
SHALL BE UPON THE APPROVAL OF THE SANITARY ENGINEER.
100mmØ PVC SP
ANGULAR SPACE BETWEEN PIPE AND SLEEVE SHALL BE FIILIED WITH COAL TAR,
ASPHALT COMPOUND OR ANY OTHER MATERIALS FOUND EQUALLY APPROVED.
5. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. 75mmØ PVC WP WC
LAV
WC
150mmØ PVC DP
9. ALL B.I. PIPES FOR BRANCH LINES W/ ADEQUATE HANGERS SHALL BE
HYDROSTATICALLY TESTED AT 150 psi FOR A DURATION OF TWO (2) HOURS, AND HB
SHOULD BE WITNESSED AND CERTIFIED BY ENGINEERING REPRESENTATIVE.
AV
10. PIPE MATERIALS AND SPRINKLER HEAD SPECIFICATION SHALL CONFORM TO
150mmØ PVC DP
THE EXISTING BRAND AND REQUIREMENTS.
11. ALL SPRINKLER HEADS SHALL BE RATED AT 165F EXCEPT FOR KITCHEN AT 212F.
16. ALL HORIZONTAL WASTE PIPING 75mm Ø AND SMALLER SHALL BE LAID WITH CB2
A MINIMUM SLOPE OF TWO (2%) PERCENT AND 100mmØ AND LARGER PIPES 150mm x 145mm CHANNEL DRAIN
SHALL HAVE ONE (1%) PERCENT SLOPE.
50mm THK REINF. CONC.
50mmØ PVC WP DETACHABLE COVER 50mm THK
17. ALL CHANGES IN DIRECTION SHALL BE MADE BY THE APPROPRIATE USE OF
FROM KS CONC. PRECAST
FORTY FIVE (45) WYELONG SWEEP QUARTER BEND. ONE EIGHT (1/8) BEND WHEN
THE CHANGE OF FLOW IS FROM HORIZONTAL TO VERTICAL. A SINGLE ONE EIGHT
SANITARY SEWER AND 50mmØ PVC WP
(1/8) BEND COMBINATION MAYBE USE ONLY ON VENT PIPE. 2 STORM DRAINAGE LAYOUT
4" THK CHB
18. NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED ON HORIZONTAL
P1 SCALE: 1:100M.
IN
SOIL OR WASTE LINES. OUT
TO THE NEAREST
PUBLIC CANAL 50mmØ PVC WP
19. PROVIDE PIPE SLEEVES AT WALL OR SLAB ONE SIZE BIGGER THAN THE ACTUAL 50mmØ PVC WP
FROM KS
LINES PASSING THROUGH WALLS OR SLAB TO PROTECT FROM BREAKAGE.
PREPARED BY: ID NO.: PROJECT TITLE: CHECKED BY: SHEET CONTENTS: SHEET NO.
SUBJECT: CET-172 GENERAL PLUMBING NOTES & SPECIFICATION GREASE TRAP DETAIL