technical data

air conditioning systems


Indoor Units

FTX-GV1B
technical data

air conditioning systems


Indoor Units

FTX-GV1B
• Indoor Units • R-410A • FTX-GV1B

TABLE OF CONTENTS
FTX-GV1B

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 5


Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4 Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wiring diagram ....................................................... 8

6 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

• Split Sky Air • Indoor Units 1


• Indoor Units • R-410A • FTX-GV1B

1 Features

t i y n k U S B 1 r AVt o 0G i o 1- ld 4X npT- RFS•I 3D air flow combines vertical and horizontal auto-swing to circulate a • Titanium apatite photocatalytic air purification filter absorbs
stream of warm/cool air right to the corners of even large spaces microscopic particles, decomposes odours and even deactivates
• Indoor / outdoor unit silent operation: “Silent” buttons on the remote bacteria and viruses
control lower the operation sound of the indoor and/or outdoor unit by • Daikin’s special dry programme reduces humidity in the room without
3dBA variation in room temperature
• Home leave operation saves energy during absence • 24-Hour On/Off timer
• Powerful mode can be selected for rapid cooling • Night set mode saves energy by preventing overcooling or
overheating during night time
• Auto-restart after power failure

2 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTX-GV1B

2 Specifications

2-1 Technical Specifications FTX50GV1B FTX60GV1B FTX71GV1B


Decoration panel Colour White
Air direction control Right, Left, Horizontal, Downward
Air filter Removable/washable/Mildew proof
Dimensions Packing Height mm 1,147
Width mm 337
Depth mm 366
Unit Height mm 290
Width mm 1,050
Depth mm 238
Weight Unit kg 12
Packed Unit kg 17
Heat Exchanger Dimensions Length mm 863
Nr of Rows 2
Fin Pitch mm 1.4
Nr of Stages 16
Passes Quantity 4
Tube type 7Hi-XD
Fin Type ML fin (Multi louvre)
Fan Type Cross flow fan
Air Flow Rate Cooling High m³/min 14.7 16.2 17.4
Nominal m³/min 12.4 13.6 14.6
Low m³/min 10.3 11.4 11.6
Silent Operation m³/min 9.5 10.2 10.6
Heating High m³/min 16.1 17.4 19.7
Nominal m³/min 13.9 15.1 16.9
Low m³/min 11.5 12.7 14.3
Silent Operation m³/min 10.2 11.4 12.7
Cooling High cfm 519 572 614
Nominal cfm 438 480 516
Low cfm 364 403 410
Silent Operation cfm 335 360 374
Heating High cfm 568 614 696
Nominal cfm 491 533 597
Low cfm 406 448 505
Silent Operation cfm 360 403 448
Fan Motor Model KFD-280-23-8A
Number of steps 5 + silent, + auto
Motor Speed (cooling) High rpm 1,240 1,330 1,410
Medium rpm 1,080 1,170 1,220
Low rpm 930 1,010 1,040
Silent Operation rpm 860 920 950
Speed (heating) High rpm 1,270 1,360 1,520
Medium rpm 1,110 1,200 1,330
Low rpm 960 1,040 1,150
Silent Operation rpm 870 950 1,040
Fan Motor Output (high) W 43
Cooling Sound Power High dBA 62 61 62
Sound Pressure High dBA 43 45 46
Nominal dBA 33 41 42
Low dBA 34 36 37
Silent Operation dBA 31 33 34
Heating Sound Power High dBA 62 60 62
Sound Pressure High dBA 42 44 46
Nominal dBA 38 40 42
Low dBA 33 35 37
Silent Operation dBA 30 32 34
Refrigerant Type R-410A

• Split Sky Air • Indoor Units 3


• Indoor Units • R-410A • FTX-GV1B

2 Specifications

2-1 Technical Specifications FTX50GV1B FTX60GV1B FTX71GV1B


Piping connections Liquid (OD) Diameter (OD) mm 6.35
Gas Diameter (OD) mm 12.7 12.7 15.9
Drain Diameter (OD) mm 18 18 18
Power input Cooling Nom. kW 0.034 0.040 0.045
Heating Nom. kW 0.036 0.045 0.060
Temperature control Microcomputer control

2-2 Electrical Specifications FTX50GV1B FTX60GV1B FTX71GV1B


Power Supply Phase 1~
Frequency Hz 50
Voltage V 220-230-240
Current Nominal running Cooling A 0.16-0.15-0.15 0.19-0.21-0.19 0.21-0.20-0.19
current (RLA) - 50Hz Heating A 0.17-0.16-0.16 0.28-0.27-0.26 0.28-0.27-0.26
Wiring connections For Power Supply Quantity 3
Remark 4 for interunit wiring (included earth wiring)

4 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTX-GV1B

3 Dimensional drawing & centre of gravity


3-1 Dimensional drawing
FTX50-60GV Air flow (indoor)
(For performance and maintenance)
The mark shows piping direction

performance)
(Space for
Rear Rear

Min. 30
Left Right
(Space for
maintenance)
Min. 50 Min. 50

(Including (Space for


REQUIRED SPACE maintenance)
installation plate)

Operation lamp
Model name
Signal receiver plate
Indoor unit on/off
switch Terminal block
Room temp. thermistor with earth
(inside) terminal (inside)
Intelligent eye sensor
Timer lamp Drain hose for VP13
Gas pipe ø12.7 Cut (connection part
Front grille fixing screws Home leave lamp (the lenght of pipe outside I.D. 14.0, O.D. 18.0)
Flaps (inside) the unit: about 430) (The hose length
Liquid pipe ø 6.4 Cut of outside the unit:
Signal (the lenght of pipe outside the about 530)
transmitter unit: about 480)
BLADE ANGELS
Horizontal blade
(automatic)
Cooling Heating Dry

Infrared Fan Vertical blade (automatic) Wall hole


remote control ø 80 hole
Wall hole for STANDARD LOCATIONS OF WALL HOLES
embedded piping
ø 80 hole

3D055875A

FTX71GV
Air flow (indoor)
(For performance and maintenance)
The mark shows piping direction

performance)
(Space for
Rear Rear

Min. 30
Left Right
(Space for
maintenance)
Min. 50 Min. 50

(Including (Space for


REQUIRED SPACE maintenance)
installation plate)

Operation lamp
Model name
Signal receiver plate
Indoor unit on/off
switch Terminal block
Room temp. thermistor with earth
(inside) terminal (inside)
Intelligent eye sensor
Timer lamp Drain hose for VP13
Gas pipe ø15.9 Cut (connection part
Front grille fixing screws Home leave lamp (the lenght of pipe outside I.D. 14.0, O.D. 18.0)
Flaps (inside) the unit: about 430) (The hose length
Liquid pipe ø 6.4 Cut of outside the unit:
Signal (the lenght of pipe outside the about 530)
transmitter unit: about 480)
BLADE ANGELS
Horizontal blade
(automatic)
Cooling Heating Dry

Infrared Fan Vertical blade (automatic) Wall hole


remote control ø 80 hole
Wall hole for STANDARD LOCATIONS OF WALL HOLES
embedded piping
ø 80 hole

3D055876A

• Split Sky Air • Indoor Units 5


• Indoor Units • R-410A • FTX-GV1B

3 Dimensional drawing & centre of gravity


3-2 Centre of gravity
FTX50-71GV

4D065971A

6 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTX-GV1B

4 Piping diagram

FTX50-60GV Indoor unit

(7.9 CuT)

Heat exchanger

Thermistor on heat exch.

Cross flow fan


Field piping

(6.4 CuT)

Fan motor
Field piping

(12.7 CuT) (12.7 CuT)

Refrigerant flow
Cooling
Heating 4D040081V

FTX71GV Indoor unit

(7.9 Cut)

Heat exchanger

Thermistor on heat exch.

Cross flow fan


Field piping

(6.4 Cut)

Fan motor
Field piping

(15.9 Cut) (12.7 Cut)

Refrigerant flow
Cooling
Heating 4D040082T

• Split Sky Air • Indoor Units 7


• Indoor Units • R-410A • FTX-GV1B

5 Wiring diagram
5-1 Wiring diagram
FTX50-71GV

Field wiring

RECTIFIER

Outdoor

Transmission CAUTION
circuit Note that operation will restart
automatically if the main power
supply is turned off and then back
on again.

LED1 LED2 LED3

Intelligent eye
sensor

Indoor
Signal
receiver
infrared
remote
control

FG Frame ground PCB1~PCB5 Printed circuit board


FU Fuse R1T,R2T Thermistor
H1~H3 Harness S1~S38 Connector
H1P~H3P Pilot lamp S1W Operation switch
M1F Fan motor X1M Terminal strip
M1S, M2S Swing motor Protective earth

3D038530T

8 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTX-GV1B

6 Sound data
6-1 Sound pressure spectrum
FTX50GV
Cooling Heating
Octave band sound pressure level dB (0 dB = 0.0002μ bar)

Octave band sound pressure level dB (0 dB = 0.0002μ bar)


Approximate Approximate
threshold hearing threshold hearing
for continuous for continuous
noise noise

Octave band center frequency - IEC (Hz) 3D050979B Octave band center frequency - IEC (Hz) 3D050979B
NOTES 50Hz NOTES 50Hz
Scale 220-240V Scale 220-240V
1 Over All (dB): H L 1 Over All (dB): H L
(B,G,N is already rectified) A 43 34 (B,G,N is already rectified) A 42 33
2 Measuring place: measure in anechoic room. 2 Measuring place: measure in anechoic room.
3 Operation noise differs with operation and ambient conditions. 3 Operation noise differs with operation and ambient conditions.
4 Location of microphone. 4 Location of microphone.
1m 1m
JISC9612 JISC9612
The operation noise The operation noise
0.8m

0.8m
measuring method is in measuring method is in
accordance with JISC9612 accordance with JISC9612

3D050979B

FTX60GV
Cooling Heating
Octave band sound pressure level dB (0 dB = 0.0002μ bar)

Octave band sound pressure level dB (0 dB = 0.0002μ bar)

Approximate Approximate
threshold hearing threshold hearing
for continuous for continuous
noise noise

Octave band center frequency - IEC (Hz) 3D051227D Octave band center frequency - IEC (Hz) 3D051227D
NOTES 50Hz NOTES 50Hz
Scale 220-240V Scale 220-240V
1 Over All (dB): H L 1 Over All (dB): H L
(B,G,N is already rectified) A 45 36 (B,G,N is already rectified) A 44 35
2 Measuring place: measure in anechoic room. 2 Measuring place: measure in anechoic room.
3 Operation noise differs with operation and ambient conditions. 3 Operation noise differs with operation and ambient conditions.
4 Location of microphone. 4 Location of microphone.
1m 1m
JISC9612 JISC9612
The operation noise The operation noise
0.8m

0.8m

measuring method is in measuring method is in


accordance with JISC9612 accordance with JISC9612

3D051227D

• Split Sky Air • Indoor Units 9


• Indoor Units • R-410A • FTX-GV1B

6 Sound data
6-1 Sound pressure spectrum
FTX71GV
Cooling Heating
Octave band sound pressure level dB (0 dB = 0.0002μ bar)

Octave band sound pressure level dB (0 dB = 0.0002μ bar)


Approximate Approximate
threshold hearing threshold hearing
for continuous for continuous
noise noise

Octave band center frequency - IEC (Hz) 3D051225D Octave band center frequency - IEC (Hz) 3D051225D
NOTES 50Hz NOTES 50Hz
Scale 220-240V Scale 220-240V
1 Over All (dB): H L 1 Over All (dB): H L
(B,G,N is already rectified) A 46 37 (B,G,N is already rectified) A 46 37
2 Measuring place: measure in anechoic room. 2 Measuring place: measure in anechoic room.
3 Operation noise differs with operation and ambient conditions. 3 Operation noise differs with operation and ambient conditions.
4 Location of microphone. 4 Location of microphone.
1m 1m
JISC9612 JISC9612
The operation noise The operation noise
0.8m

0.8m
measuring method is in measuring method is in
accordance with JISC9612 accordance with JISC9612

3D051225D

10 • Split Sky Air • Indoor Units


Daikin’s unique position as a manufacturer of air Daikin Europe N.V. is approved by LRQA for its Quality The present publication is drawn up by way of information only and does not
conditioning equipment, compressors and Management System in accordance with the ISO9001 constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
refrigerants has led to its close involvement in standard. ISO9001 pertains to quality assurance regarding compiled the content of this publication to the best of its knowledge. No
environmental issues. For several years Daikin has design, development, manufacturing as well as to services express or implied warranty is given for the completeness, accuracy,
had the intension to become a leader in the provision related to the product. reliability or fitness for particular purpose of its content and the products and
of products that have limited impact on the services presented therein. Specifications are subject to change without
environment. This challenge demands the eco design prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or
and development of a wide range of products and an indirect damage, in the broadest sense, arising from or related to the use
energy management system, resulting in energy and/or interpretation of this publication. All content is copyrighted by Daikin
conservation and a reduction of waste. Europe N.V..
Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for

Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B- 8400 Oostende

ISO14001 assures an effective environmental


management system in order to help protect human health
and the environment from the potential impact of our
activities, products and services and to assist in
maintaining and improving the quality of the environment.
the environmont is set in the EMAS and ISO 14001 systems.

Daikin units comply with the European regulations that


guarantee the safety of the product.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
Copyright Daikin

VRV® products are not within the scope of the Eurovent


www.daikin.eu certification programme.
BE 0412 120 336
RPR Oostende

You might also like