Manufacturer Esaote SpA Esaote SpA Esaote SpA

MyLab Seven MyLab Six MyLab Twice

WHERE MARKETED Worldwide Worldwide Worldwide

FDA CLEARANCE Yes Yes Yes


CE MARK (MDD) Yes Yes Yes
CLINICAL APPLICATIONS Cardiac (adult, Cardiac (adult, Cardiac (adult,
pediatric), vascular, pediatric), vascular, pediatric), vascular,
OB/GYN, general OB/GYN, general OB/GYN, general
imaging (adult, imaging (adult, imaging (adult,
neonatal, pediatric), neonatal, pediatric), neonatal, pediatric),
abdominal, cephalic abdominal, cephalic abdominal, cephalic
(adult, neonatal), (adult, neonatal), (adult, neonatal),
breast, breast, breast,
musculoskeletal, musculoskeletal, musculoskeletal,
pediatric, small parts, pediatric, small parts, pediatric, small parts,
thyroid, thyroid, urology thyroid,
intraoperative/interve intraoperative/interve
ntional, urology ntional, urology

PROBE TYPES, MHz


Linear array 3-18 3.3-18 3.3-22

Convex array 1-8 Not specified Not specified

Phased/vector array 1-8 1-10 1-10

Multifrequency All All probes All probes

Endovaginal Yes Not specified Not specified

Endorectal Yes Not specified Not specified

TEE Yes Not specified Not specified


CW Yes Pedoff and pencil Pedoff and pencil
CW Doppler CW Doppler

Others Volumetric Endocavity, Endocavity,


intraoperative, intraoperative,
microconvex, microconvex,
volumetric, volumetric,
laparoscopic, laparoscopic,
transesophageal, transesophageal,
1.8-18 all 1.8-18 all
multifrequency multifrequency,
probes for point-of-
care unit include
functional buttons,
ultra-high frequency
22 MHz

GRAYSCALE LEVELS 256 256 256


PREPROCESSING Yes Yes Yes

POSTPROCESSING Yes Yes Yes

IMAGING MODES
M-mode display Yes Yes Yes
M-mode and 2-D Yes Yes Yes
3-D (freehand) Noncardiac only Noncardiac only Noncardiac only
3-D (automatic) Not specified Not specified Not specified
4-D (live 3-D) Noncardiac only Noncardiac only Noncardiac only

Harmonic imaging Yes Yes Yes

DOPPLER
Type Color, power, Velo- Color, power, Velo- Color, power, Velo-
power, Xflow, PW, power, Xflow, PW, power, Xflow, PW,
CW CW CW

Frequency display Not specified Not specified Not specified


Velocity display Yes Yes Yes
Power Doppler Yes Yes Yes
Duplex mode Yes Yes Yes
Triplex mode Yes Yes Yes
FUNCTIONALITY
Digital calipers Yes Yes Yes
Selectable dynamic range Yes Yes Yes
Adjustable transmit focus Yes Yes Yes
Dynamic receive focus Yes Yes Yes
Measurements on video Not specified Not specified Yes
replay
PAN/ZOOM
Real-time image Yes Yes Yes

Frozen image Yes Yes Yes


IMAGE STORAGE Not specified Not speecified Not specified

Capacity, number of stored 250 GB HD 250 GB HD 250 GB HD


images

Cine ≤1,000 frames ≤1,000 frames ≤5,000 frames

DICOM 3.0 COMPLIANT Yes Yes Yes


PHYSIOLOGIC DATA Not specified ECG ECG

ANALYSIS PACKAGES
Cardiac scanning No Yes Yes
Vascular scanning Yes Yes Yes
OB/GYN scanning Yes Yes Yes
Stress echo Yes Yes Yes
Others Standard calculation Standard calculation Standard calculation
packages for: packages for: packages for:
Abdomen, breast, Abdomen, breast, Abdomen, breast,
cardiology, cardiology, cardiology,
gynecology, obstetric gynecology, obstetric gynecology, obstetric
with programmable with programmable with programmable
tables, pediatric, tables, pediatric, tables, pediatric,
small parts, thyroid, small parts, thyroid, small parts, thyroid,
transcranial, urology, transcranial, urology, transcranial, urology,
vascular standard vascular, standard vascular, standard
biometry reports and biometry reports and biometry reports and
user programmable user programmable user programmable
reports, generic reports, generic reports, generic
measurements, measurements, measurements,

NUMBER OF USER- Two different Two different Two different


PROGRAMMABLE accounts: accounts: accounts:
PROTOCOLS andministrator and andministrator and andministrator and
user; multiple users, user; multiple users, user; multiple users,
login by user, no limit login by user, no limit login by user, no limit
for programmable for programmable for programmable
protocols protocols protocols

USER-PROGRAMMABLE Yes Not specified Not specified


FORMULAS AND TABLES
NEEDLE GUIDES
Transrectal Yes Yes Yes
Transperineal Yes No Yes

MONITOR Single, 43.2 cm (17") Single 43.2 cm (17") Single, 48.2 cm (19")
LCD, 22.6 cm(8.9") or 48.2 cm (19") HD high resolution LCD,
LCD touchscreen LCD, 22.6 cm (8.9") 22.6 cm (8.9") LCD
LCD touchscreen touchscreen

SPLIT SCREEN Yes Yes Yes

POWER REQUIREMENTS 110/220, 50/60 Hz; 110/220, 50/60 Hz 110/220, 50/60 Hz


system standby
battery

H x W x D, cm (in) [122-143] x 49 x 70 [139-151] x 61 x 65 [148-155] x 63 x 102


([49-58] x 18 x 29) ([54-59] x 24 x 25.5) ([58-61] x 25 x 40)

WEIGHT, kg (lb) 65 (143) 55 (121) 100 (220)


PURCHASE INFORMATION
List price Not specified Not specified Not specified
Warranty 1-5 years 1-5 years 1-5 years

Delivery time, ARO Not specified Not specified Not specified

GREEN FEATURES Not specified Not specified Not specified


OTHER SPECIFICATIONS Reports stored Reports stored Reports stored
automatically in automatically in automatically in
patient file; for patient file. patient file; optional
advanced cardiac 2-in-1 satellite system
users. for added point-of-
care imaging while
freeing main system
for in-depth studies.

UMDNS CODE(S) 15976 15976 15976

LAST UPDATED October 2014 October 2014 October 2014


Supplier Footnotes
Model Footnotes
Data Footnotes
Fukuda Denshi Co Fukuda Denshi Co GE Healthcare USA GE Healthcare USA
Ltd Ltd LOGIQ E9 LOGIQ P5
UF-760 0AG UF-870AG

Worldwide Worldwide, except Worldwide Worldwide


USA
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, Abdominal, Abdominal, breast, Abdominal, breast,
cardiology, OB/GYN, cardiology, OB/GYN, intraoperative, cardiac, endocavity,
small parts, urology, small parts, urology, musculoskeletal, musculoskeletal,
vascular vascular OB/GYN, orthopedic, neontal, OB/GYN,
pediatric and pediatricl, small parts,
neonatal, peripheral, transcranial,
transcranial, urological, vascular
urological, vascular

5-12 5-12 9L-D, 11L-D, ML6- 8L, 9L, 10L, 11L,


15-D, RSP6-16-D 12L, i12L

2-5, 4-9 2-5, 4-9 C1-5-D, M6C-D, 3.5C, 4C, 5CS, 8C,
3CRF E8C, E8CS, BE9C

1-5, 2-5, 3-8 1-5, 2-5, 3-8 S1-5, M4S-D 3S, 5S, 7S, 3Sp, 5Sp

Yes Yes Yes All probes

3-8 4-7 IC5-9-D, RIC5-9-D E8C, E8CS, 4DE7C

NA No IC5-9-D E8C, E8CS, 4DE7C,


BE9CS
Not specified Not specified Not specified Not specified
Not specified Not specified Not specified P6D, P2D

Volume probe 3-6, Volume probe 3-6 Not specified 4D8C, 4D3C-L,
finger probe 5-12 4D5C-L, I739, T739,
ERB

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Including raw data


stored images

Yes Yes Yes Yes


Yes Yes Not specified Yes
No No Not specified Yes
Optional Optional Yes Yes
Optional Optional Yes Yes

Yes Yes Yes Yes


CW, PW CW, PW PW, PDI, color flow PW-HPRF, CWD,
mode PDI

Yes Yes Not specified Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Not specified Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Yes (viewing)

Yes Yes Yes Yes

Yes Yes Yes Yes


CD-R, HDD, printer, CD-R, HDD, printer, CD, DVD, HD, USB HD, DVD-R, CD-R,
USB, VCR USB, VCR videotape, USB
memory stick

160 GB 160 GB 40 GB HDD, 28 GB 40 GB HDD, 28 GB


images images

Yes Yes Not specified 970 frames, ≤60 sec


(192 MB)

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Optional Optional Not specified Not specified
NA None specified M-mode, B-mode, OB/GYN, urological,
Doppler calculations renal, fetal trending,
hip

Not specified Not specified Yes Extensive

OB/GYN, cardiac OB/GYN, cardiac Yes Yes

No No Not specified Yes


No No Not specified Yes, with ERB probe

Single Single Not specified Single 38.1 cm (15")


LCD monitor with
articulating arm

Yes Yes Not specified Yes

110-240 VAC 110-240 VAC 10% Not specified 100-120/220-240


VAC, 50/60 Hz, ≤750
VA

9.8 x 37 x 36 (3.9 x [132-151] x 48 x 83 141 x 58.4 x 83 (55.5 [135-141] x 43 x 64


14.6 x 14.2) ([52-59.4] x 18.9 x x 23 x 32.7) ([49-58] x 17 x 25)
32.7)

6.9 (15.2) 100 (220) Not specified 75 (165)


Not specified Not specified Not specified $45,000
1 year 1 year 1 year 1 year

Not specified 30 days Not specified 2-4 weeks

None specified None specified None specified None specified


None specified. Xtrillion digital-beam- Volume navigation; Raw data; coded
forming chip real-time ultrasound excitation; SRI;
technology provides with CT, MR, CrossXBeam; virtual
underlying foundation ultrasound images; convex; LOGIQView;
for high frame rates, customizable Scan B-flow; ECG option;
high-definition Assistant; raw data; storage drawer; TEE;
imaging, and power assisted TVI and Q-analysis;
increased axial control panel; pulsatile flow
resolution in the XT articulating LCD arm detection; B-steer.
and XTD ultrasound and lightweight
product lines. transducers.

15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052

August 2014 August 2014 July 2011 June 2014


GE Healthcare USA GE Healthcare USA GE Healthcare USA GE Healthcare USA
LOGIQ P6 LOGIQ S7 LOGIQ S8 Voluson E6

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Abdominal, breast, Abdominal, Abdominal, Abdominal, breast,
cardiac, endocavity, anesthesia, breast, anesthesia, breast, cardiology,
musculoskeletal, cardiac, MSK, cardiac, MSK, neurological,
neonatal, OB/GYN, neonatal, OB/GYN, neonatal, OB/GYN, OB/GYN, orthopedic,
pediatric, small parts, pediatric, pediatric, pediatric and
transcranial, rheumatology, small rheumatology, small neonatal, small parts,
urological, vascular parts, vascular parts, vascular transcranial, urology,
vascular

8L, 9L, 11L, i12L 9L-D (2-8), 11L-D 9L-D (2-8), ML6-15-D SP10-16-D, 11L-D,
(4.2-12), ML6-15-D (4-15 matrix) 9L-D, RSP6-16-D
(4-15 matrix)

4C, 5CS, 8C, E8C, C1-5-D (1.8-5), 8C C1-5-D (1.8-5), 4C-D, C1-5-D, RAB6-
E8CS, BE9C (3.6-10 microconvex) 3CRF-D D, C4 8-D

3S, 5S, 7S, 3Sp, 5Sp 3Sp-D (1.6-5.5), S4- M5S-D, S4-10-D 3S-D
10-D (3.6-10)

All probes Yes Yes Yes

E8C, E8CS, 4DE7C IC5-9-D (3.6-9 IC5-9-D (3.6-9) end- IC5-9-D, RIC5 9-D
microconvex) fire
E8C, E8CS, 4DE7C, IC5-9-D (3.6-9 IC5-9-D (3.6-9) end- IC5-9-D
BE9CS microconvex) fire
6T P2D (2), P6D (6) Not specified Not specified
P6D, P2D Not specified Not specified Yes

4D3C, 4D5C, I739, L8-18i (5-18 hockey L8-18i-D (5-18 Not specified
T739, ERB stick) hockey stick)

256 256 256 256


Yes Yes Yes Yes

Including raw data Yes Yes Yes


stored images

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Not specified
Yes Yes Yes Yes
Yes Yes No Yes

Yes Yes Yes Yes


PD, PW, CW PW, CW, CDI, PDI PW, CDI, PDI PW-HPRF, CW, PD,
color flow TD, HD
flow

Yes Yes Yes Not specified


Yes Yes Yes Not specified
Yes Yes Yes Not specified
Yes Yes Yes Not specified
Yes Yes Yes Not specified

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes (viewing) Yes, DVR Yes, DVR Not specified

Yes Yes Yes Yes

Yes Yes Yes Yes


HD, DVD-R, CD-R, Not specified Not specified CD-R, DVD, USB
videotape, USB
memory stick

80 GB HDD, 65 GB Not specified 160 GB HDD 112 GB 280 GB HDD


images

1,200 frames, ≤60 Not specified 891.3 ≤256 MB, ≤8,000 2-D
sec (192 MB) images

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
OB/GYN, urological, Not specified Not specified M-mode, B-mode,
renal, fetal trending, Doppler calculations
hip

Extensive Not specified Not specified Yes

Yes Not specified Not specified Yes

Yes Yes Yes Not specified


No Not specified No Not specified

Single 43.2 cm (17") Single 48.3 cm (19") Single 48.3 cm (19") 48.3 cm (19'')
LCD monitor with LCD with articulating LCD with articulating noninterlaced, high
articulating arm arm arm resolution

Yes Yes Yes Yes

100-120/220-240 Not specified 100-120 or 220-240 100-130/220-240,


VAC, 50/60 Hz, ≤750 VAC 50/60 Hz, ≤1,010 VA
VA

[125-147] x 43 x 64 Not specified [175-115.1] x 58.4 x 129 x 58 x 93 (50.8 x


([49-58] x 17 x 25) 82.6 ([68.9-45.3] x 23 22.8 x 36.6)
x 32.5)

80 (176) Not specified 85 (187.4) 120 (265)


$85,000 $161,440<1> $232,799<1> Not specified
1 year Not specified Not specified Upon request

1-2 weeks Not specified Not specified Not specified

None specified None specified None specified None specified


Raw data; coded Platform is highly Coded harmonic STIC; multiplanar
excitation; SRI-HD; configurable; optional imaging; LOGIQView modes; VCI;
CrossXBeam; virtual scan assistant; (extended FOV); B- SonoVCAD;
convex; LOGIQView; CrossXBeam; multi- Flow, AutoEF (semi- SonoAVC; Scan
B-flow; ECG option; modality query automatic Assistant; floating
storage drawer; TEE; retrieve; B-Flow; B- measurement of user interface;
TVI and Q-analysis; Steer and needle ejection fraction); electrical height
pulsatile flow recognition; volume Scan Assistant; adjustment; raw data.
detection; B-steer. imaging. CrossXBeam; OB
Measure Assistant;
breast and thyroid
productivity
packages; wireless;
raw data (allows
measurements and
image adjustments
after image
acquisition); Power
Assistant;
elastography; Auto
IMT.

15657, 15957, 15976 15976 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052

June 2014 July 2014 July 2014 July 2014

<1>Pricing <1>Pricing
information derived information derived
from ECRI Institute's from ECRI Institute's
PricePaid database. PricePaid database.
GE Healthcare USA GE Healthcare USA GE Healthcare USA GE Healthcare USA
Voluson E8 Expert Voluson P8 Voluson S6 Voluson S8

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Abdominal, breast, Abdominal, breast, Abdominal, breast, Abdominal, breast,
cardiology, OB/GYN, orthopedic, OB/GYN, orthopedic, OB/GYN, orthopedic,
musculoskeletal, pediatric and pediatric and pediatric and
OB/GYN, orthopedic, neonatal, small parts, neonatal, small parts, neonatal, small parts,
pediatric and urology, vascular urology, vascular urology, vascular
neonatal, small parts,
transcranial, urology,
vascular

SP10-16-D, 9L-D, 12L-R5 12L-RS 12L-RS


11L-D, RSP6-16-D,
RSM5-14

4C-D, C1-5-D, C4-8- 4C-RS, RAB2-6-RS 4C-RS, RAB2-6-RS C1-5-RS, 4C-RS,


D, RAB6-D, RM6C-d RAB6-RS

3S-D Not specified Not specified Not specified

Yes Yes Yes Yes

IC5-9-D, RIC5-9-D, E8C-RS, RICS-9W- E8C-RS, RIC5-9W- E8C-RS, RIC5-9W-


RIC6-12 RS RS RS
IC5-9-D E8C-RS, RICS-9W- E8C-RS, RIC5-9W- E8C-RS, RIC5-9W-
RS RS RS
Not specified Not specified Not specified Not specified
Yes Not specified Not specified Not specified

Not specified Not specified Not specified Not specified

256 256 256 256


Yes Not specified Not specified Not specified

Yes Not specified Not specified Not specified

Yes Yes Yes Yes


Yes Not specified Not specified Not specified
No Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


Color, tissue, PD, PW-HPRF, PD, HD PW-HPRF, PD, HD PW-HPRF, PD, HD
CW, PW with HPRF, flow, color flow TD flow, color flow TD flow, color flow TD
HD flow

Yes Not specified Not specified Not specified


Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Not specified Not specified Not specified

Yes Yes Yes Yes

Yes Yes Yes Yes


HD, MOD, CD-RW, CD-R, DVD, USB CD-R, DVD, USB CD-R, DVD, USB
DVD, USB

280 GB HD 120 GB HDD 120 GB HDD 120 GB HDD

≤256 MB, ≤8,000 2-D ≤256 MB, ≤8,000 2-D ≤256 MB, ≤8,000 2-D ≤256 MB, ≤8,000 2-D
images images images images

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
M-mode, B-mode, M-mode, B-mode, M-mode, B-mode, M-mode, B-mode,
Doppler calculations Doppler calculations Doppler calculations Doppler calculations

Extensive Yes Yes Yes

Yes Yes Yes Yes

Not specified Not specified Not specified Not specified


Not specified Not specified Not specified Not specified

48.3 cm (19'') 38.1 cm (15'') 48.3 cm (19'') 48.3 cm (19")


noninterlaced, high noninterlaced, high noninterlaced, high
resolution resolution resolution

Yes Not specified Not specified Not specified

100-130/220-240 100-130/220-240 100-130/220-240 100-130/220-240


VAC, 50/60 Hz, VAC, 50/60 Hz, VAC, 50/60 Hz, VAC, 50/60 Hz,
≤1,010 VA ≤1,010 VA ≤1,010 VA ≤1,010 VA

129 x 57.9 x 93 (50.8 Not specified [97.5-172.5] x 62 x [97.5-172.5] x 62 x


x 22.8 x 36.6) 84.8 ([38.4-67.9] x 84.8 ([38.4-67.9] x
24.4 x 33.4) 24.4 x 33.4)

120 (265) Not specified Not specified Not specified


Not specified Not specified Not specified Not specified
Upon request Upon request Upon request Upon request

30-60 days Not specified Not specified Not specified

None specified None specified None specified None specified


Real-time 4-D; real- Auto optimization; Auto optimization; Auto optimization;
time 4-D biopsy; Scan Assistant; raw VCI; SonoVCAD; STIC; multiplanar;
volume calculation data; floating user Scan Assistant; raw multiple rendering
(VOCAL); volume interface. data; floating user modes; OmniView;
contrast imaging interface. VCI; SonoVCAD;
(VCI); SonoVCAD, SonoAVC; Scan
SonoAVC, coded Assistant; raw data;
harmonic imaging floating user
(THI); compound interface.
resolution imaging
(CRI); tissue color
Doppler imaging; 4-D
fetal cardio (STIC);
coded excitation
(CE); auto
optimization
frequency and focus
composite (FFC); B-
flow; virtual convex;
RSP biopsy kit;
DICOM print, store,
worklist, lossy JPEG,
3-D rotation/4-D as
DICOM MF, batch
print/send, spooler,
simultaneous
worklist/local archive.

15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052

July 2014 August 2014 August 2014 August 2014


Hitachi Aloka Hitachi Aloka Hitachi Aloka Hitachi Aloka
America America America America
Arietta 70 Hi Vision Preirus Noblus ProSound Alpha 6

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Radiology, Radiology, Radiology, Breast, interventional
cardiology, vascular, interventional cardiology, urology, radiology,
TEE radiology, OB/GYN, interventional musculoskeletal,
vascular, breast, radiology, OB/GYN, OB/GYN, radiology,
small parts, vascular, breast, small parts, urology,
musculoskeletal small parts, vascular
musculoskeletal,
brachytherapy

3-18 3-18 3-18 4.4-15

1-5 1-10 1-10 2-10

1-9 2-9 1-9 3-8

Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes No Yes


Yes Yes Yes Yes

Not specified Pediatric transrectal, Intercostal offset Linear array robotic


through-crystal biopsy, through surgery, 4-way
biopsy guidance, crystal biopsy laparoscopic, End-
neonatal micro- guidance, bi-plane Fire laparoscopic,
convex, offset transrectal, hockey burr-hole guidance,
intercostal convex, stick, 360 degree micro-surgery
linear-hockey stick, pediatric and adult guidance, Hockey-
200 degree field-of- transrectal, 150 Stick linear array,
view micro-convex degree 4-D linear array rigid
endocavity endocavity, single laparoscopic, narrow-
crystal pediatric, 200 view Side-Fire “T”,
degree end-fire linear array 2-way
prostate biopsy laparoscopic, linear
array side-fire “T”,
curved array “I” style
finger-grip, curved
array “T” style finger-
grip, ranial guidance
transducer

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


PW, steerable CW, PW, CW, HPRF-PW, PW, CW, HPRF-PW, PW, CW, HPRF-PW,
HPRF-PW, tissue tissue doppler, Dual tissue Doppler, Dual tissue Doppler, Dual
Doppler, Dual Gate Gate doppler, Fine Gate Doppler, Fine Gate Doppler, D-
Doppler, D-eFlow FLOW FLOW eFLOW

Yes Yes Yes Yes


Yes Yes Yes Yes
Directional Directional Directional Directional
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


HDD, DVD-RAM, HDD, DVD-RAM, HDD, DVD-RAM, HDD, DVD-RAM,
CD-R, USB memory, CD-R, USB memory, CD-R, USB memory, CD-R, USB memory,
USB HDD, PACS USB HDD, PACS USB HDD, PACS USB HDD, PACS

72,000 ~72,000 ~63,000 <150,000 static


images

Not specified Not specified 19,000 frames Yes

Yes Yes Yes Yes


Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes No Yes
Contrast Echo, General General, urology, Urological
automated segmental musculoskeletal, measurements and
pediatric, small parts calculations,
brachytherapy grid
display, Real-time
Multi-Free Angular M-
Mode

100 22 22 45

Yes Yes Yes Yes

Yes No Yes Yes


No No Yes No

Single Single Single Single

Yes Yes Yes Yes

100-120/200 to 240 V 100/110, 120, 220- 120/240 V, 60 Hz 115/220-240 VAC,


±10%, 50/60 Hz 240 V ±10%, 50/60 50/60 Hz
Hz

[130-175] x 53.5 x 79 [135-1550] x 45 x [112.5-132.6] x 52.1 [130-155] x 42 x 70


([51.2-68.9] x 21.1 x [90-110] ([53-61] x x 51.8 ([44.3-52.2] x ([51-61] x 16.5 x
31.1) 17.7 x [35.4 x 43.3]) 20.5 x 20.4) 27.6)

117 (258) main unit 190 (419) 40 (88.2) 70 (156)


only
Not specified $130,720 $60,000 $101,900
1 year 1 year 1 year 1 year

30-45 days 30-45 days 30-45 days 30-45 days

Not specified None specified None specified None specified


Elastography; Real- Elastography, Real- Power consumption Dual Dynamic
time Virtual time Virtual is only 250 W (550 W Display (DDD).
Sonography (RVS); Sonography (RVS). using cart);
eTRACKING; wave removable console
intensity; Dual contains an internal
Dynamic Display battery allowing
(DDD); Dynamic examinations to be
Slow-motion Display performed even
(DSD). when an external
power source is not
available; supports
wireless LAN for
DICOM
communication.

15657, 15957, 15976 15976 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052

June 2014 June 2014 June 2014 June 2014


Hitachi Aloka Hitachi Aloka Hitachi Aloka Hologic Inc
America America America Aixplorer MultiWave
ProSound Alpha 7 ProSound F37 ProSound F75 Ultrasound System

Worldwide Worldwide Worldwide USA

Yes Yes Yes Yes


Yes Yes Yes Yes
Brachytherapy, Breast, Breast, interventional Abdominal, breast,
breast, cardiology, muscoloskeletal, radiology, endorectal,
musculoskeletal, OB/GYN, radiology, musculoskeletal, endovaginal,
neurosurgery, small parts OB/GYN, radiology, genitourinary,
OB/GYN, radiology, small parts, TEE, musculoskeletal,
small parts, TEE, urology, vascular pediatric, pelvic,
urology, vascular renal, thyroid,
vascular

3-13.3 5-13 2.5-13.33 4-15, 2-10

1.5-13 2-7.5 1.3-10 1-6

1-8 No No NA

Yes Yes Yes Yes

Yes Yes Yes 3-12

Yes Yes Yes 3-12

Yes Yes Yes NA


Yes Yes Yes NA

Pediatric TEE, Not specified Pediatric TEE, 3-D (5-16),


neonatal sector through-crystal microconvex (3-12)
array, linear array biopsy guidance
robotic surgery,
curved array 4-way
laparoscopic, Linear
array 4-way
laparoscopic, linear
array rigid
laparoscopic, phased
array burr-hole, End-
Fire laparoscopic,
linear array micro-
surgery, flexible
linear array, Hockey-
Stick linear array,
narrow-view Side-
Fire “T”, linear array
side-fire “T”, linear
array 2-way
laparoscopic, 60mm
linear, cranial
guidance, curved
array “I” style finger-
grip, curved array “T”
style

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes NA


Yes Yes Yes 2-D
Yes Yes Yes NA
Yes Yes No Yes
Yes Yes Yes NA

Yes Yes Yes Yes


PW, CW, HPRF-PW, PW, CW, HPRF-PW, PW, CW, HPRF-PW, CFI, CPI, dCPI, PW,
tissue Doppler, Dual tissue Doppler, Dual tissue Doppler, Dual UltraFast Doppler
Gate Doppler, D- Gate Doppler, D- Gate Doppler, D-
eFLOW eFLOW eFLOW

Yes Yes Yes Yes


Yes Yes Yes Yes
Directional Directional Directional Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


HDD, DVD-RAM, HDD, DVD-RAM, HDD, DVD-RAM, Not specified
CD-R, USB memory, CD-R, USB memory, CD-R, USB memory,
USB HDD, PACS USB HDD, PACS USB HDD, PACS

<150,000 static <150,000 static <150,000 static >20,000


images images images

~20,000 frames 12,800 frames 61,450 frames ≤3 min @ 30 fps

Yes Yes Yes Yes


Yes Yes Yes Heart rate calculated
from PW Doppler or
M-mode

Yes Yes Yes No


Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Yes Yes No
Contrast echo, Fetal growth analysis, Urological Breast BI-RADS,
automated Real-time Multi-Free measurements and thyroid Thy-RADS,
segmental, motion Angular M-Mode calculations, small abdominal, renal,
analysis, flow parts measurements pelvic, genitourinary,
mediated, dilatation and calculations, musculoskeletal,
analysis, TDI abdominal vascular, pediatric
analysis, Real-time measurements and
Multi-Free Angular M- calculations, Real-
Mode time Multi-Free
Angular M-Mode

45 45 45 NA

Yes Yes Yes Yes

Yes Yes No Yes


Yes No No Yes

Single Single Single Single, 21.5" LCD

Yes Yes Yes Yes

115/200 to 240 V 100-120/200-240 V 115/200 to 240 V 100-120 VAC, 50/60


±10%, 50/60 Hz ±10%, 50/60 Hz ±10%, 50/60 Hz Hz, 1,500 W; 220-
240 VAC, 50/60 Hz

[142-173] x 49 x 79 [130-155] x 42 x 70 [120-168] x 59 x 100 [131-169] x 61 x 105


([56-68] x 19.3 x ([51.2 x 61] x 16.5 x ([47.2-66.1] x 23.2 x ([51-67] x 24 x 41)
31.1) 27.5) 39.4)

108 (238) 65 (143) 170 (375) 97 (214)


$119,000 $32,600 $137,900 $142,000
1 year 1 year 1 year 1 year

30-45 days 30-45 days 30-45 days 30-45 days

None specified None specified None specified None specified


Elastography; remote Dual Dynamic Remote control; Dual Ergonomic cart;
control; Dual Display (DDD). Dynamic Display optimized presets for
Dynamic Display (DDD); Dynamic all clinical
(DDD); Dynamic Slow-motion Display applications; user
Slow-motion Display (DSD); eTracking, customizable presets;
(DSD); eTracking, Wave Intensity. Tissue Tuner; Shear
wave intensity. Wave Elasto;
SonicSoftware
Beamforming and
Scan Conversion;
Ultrafast Doppler
Imaging; Integrated
Touch Screen with
TouchRing and Track
Ball; Interactive Picto
Body Markers;
annotations
packages; full post-
processing in review.

15657, 15957, 15976 15976 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052

June 2014 June 2014 June 2014 August 2014


Mindray Medical Mindray Medical Mindray Medical Mindray Medical
International Ltd International Ltd International Ltd International Ltd
DC 7 DC-8 DC-N3 DC-T6

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Abdominal, breast, Abdominal, breast, Abdominal, breast, Abdominal, breast,
cardiology, EM, cardiology, EM, cardiology, cardiology, EM,
endocavity, endocavity, endocavity, endocavity,
intraoperative, intraoperative, intraoperative, intraoperative,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
nerve, OB/GYN, nerve, OB/GYN, nerve, OB/GYN, nerve, OB/GYN,
orthopedic, pediatric, orthopedic, pediatric, orthopedic, prostate, orthopedic, pediatric,
prostate, small parts, prostate, small parts, small parts, urology, prostate, small parts,
TCI, urology, TCI, urology, vascular TCI, urology,
vascular vascular vascular

2-16 2.6-16 3.7-16 2-16

1.5-12 1.3-12.8 1.7-11.3 1.5-12

1.3-13.5 1.3-11.4 1.5-5 1.3-8

All transducers All transducers Al transducers All transducers

3.6-10 2.6-12.8 3.4-11 3.6-10

3-11 2.6-12.8 Not specified 3-11

3.5-13.5 3.1-8.2 Not specified 3.1-7.2


5 2 and 5 Not specified 2 and 5

Intraoperative Volume transducer Volume transducer Not specified


transducer, volume
transducer

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes No Yes

Yes Yes Yes Yes


PW/CW PW/CW PW/CW PW/CW

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

8 sets 8 sets 8 sets 8 sets


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


HD, USB, CD-RW HD, USB, DVD-RW, HD, flash memory, HD, USB, CD-RW
DVR USB, CD-RW

320 GB >800 GB or 113,664 270 GB 320 GB


frames

6,156 13,335 frame or 145 ≤12,392 frames or 1,024


sec (mode 169.6 sec
dependent)

Optional Optional Optional Optional


ECG ECG ECG ECG

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Yes
Abdominal, small Abdominal, small Abdominal, small Abdominal, small
parts, endocavity, parts, endocavity, parts, endocavity, parts, endocavity,
urology, prostate, urology, prostate, urology, prostate, urology, prostate,
breast, orthopedic, breast, orthopedic, breast, orthopedic, breast, orthopedic,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
nerve, intraoperative, nerve, intraoperative, nerve, intraoperative nerve, intraoperative,
pediatric, EM, TCI pediatric, EM, TCI pediatric, EM, TCI

Unlimited Unlimited Unlimited Unlimited

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Not specified Not specified Not specified

Single Single Single With external monitor

No No No No

110/220 VAC, 50/60 110/220 VAC, 50/60 110/220 VAC, 50/60 110/220 VAC, 50/60
Hz Hz Hz Hz

135 x 50 x 85 (53.1 x 136 x 59 x 93 (54 x 50 x 141.5 x 74 (19.7 46 x 73 x 129 (18.1 x


19.7 x 33.5) 23 x 37) x 55.7 x 29.1) 28.7 x 50.8)

120 (264.5) 111 (245) 62 (136.7) 95 (209)


Not specified Not specified Not specified Not specified
2 years, for unit from 1 year, for unit from 2 years from date of 2 years, for unit from
date of shipment, date of shipment, shipment, extensions date of shipment,
extensions available extensions available available extensions available

<1 week <1 week <1 week <1 week

None specified None specified None specified None specified


User customization of Elastography, User customization of User customization of
applications; multiple contrast imaging. applications; multiple applications; multiple
calculation packages Meets requirements calculation packages calculation packages
available. Meets of IEC 60601-1 and available. Meets available. Meets
requirements of IEC TUV. requirements of IEC requirements of IEC
60601-1 and TUV. 60601-1 and TUV. 60601-1 and TUV.

15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052

June 2014 June 2014 June 2014 June 2014


Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare
North America North America North America North America
ClearVue 350 ClearVue 550 EPIQ HD11 XE

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Abdominal, Abdominal, Abdominal, OB/GYN, Abdominal, breast,
cardiology, cardiology, fetal, pediatric, TCD, cardiology,
musculoskeletal, musculoskeletal, breast, small parts, endocavity,
OB/GYN, pediatric, OB/GYN, pediatric, musculoskeletal, musculoskeletal,
small parts, TCD, small parts, TCD, prostate, renal, OB/GYN, pediatric,
urology, vascular urology, vascular bladder, contrast, prostate, regional
surgical, anesthesia, small
interventional, parts, surgical, TCD,
intraoperative, vascular
endocavity,
superficial, adult
echo, pediatric echo,
stress echo, fetal
echo, TEE

L12-4 L12-4 VL13-5, L18-5, L15- L15-7io, L12-5, L12-


7io, L12-5 50 mm, 3, L9-3, L8-4
L12-3

C5-2 C5-2 C9-2 PureWave, C8- C9-4, C8-5, C6-3,


5, C5-1 PureWave, C5-2/V6-2, V8-4,
V6-2 3D9-3v

S4-1 S4-1 X5-1 xMatrix S12-4, S8-3, S7-3t,


PureWave, X7-2 S7-2omni, S4-2, S3-1
xMatrix PureWave,
X6-1 xMatrix
PureWave,S12-4,
S8-3, S5-1
PureWave

Broadband Broadband Broadband with 2-D Broadband, optional


optimization 2-D
C9-4v C9-4v C10-3v PureWave, C8-4v, 3D9-3v
3D9-3v
Not specified Not specified C10-4ec BP10-5ec, C9-5ec

Not specified Not specified X7-2t TEE xMatrix Not specified


PureWave, S7-3t
TEE
Not specified Not specified 2, 5 nonimaging Static CW Doppler

None specified None specified 1 PW transcranial; 1 PW Doppler


endocavity, 2
endovaginal

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
No No Yes Yes
No No Yes Yes

Multivariate Multivariate Multivariate including Multivariate


pulse inversion and
coded harmonics
PW, steerable CW, PW, steerable CW, PW, steerable CW, PW, steerable CW,
color Doppler, color color Doppler, color Live 3-D Echo, Live CFM, color power
power angio, HPRF power angio, HPRF xPlane, stress echo, angio, HPRF, TDI
contrast, iRotate,
XRES, SonoCT,
AutoScan, strain-
based and shear
wave elastography,
color power angio
imaging

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes iFocus Yes
Yes Yes Yes Yes
No No Yes No

HD zoom HD zoom HD zoom HD zoom

Yes Yes Yes Yes


Internal HD, CD, Internal HD, CD, Internal HD, DVD, Internal HD, DVD,
DVD, USB DVD, USB CD, USB CD, USB

320 GB for data 320 GB 1 TB 160 GB for data


storage storage

1,200 frames 1,200 frames 2,200 frames 1,000 frames

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

Yes Yes Yes Stress echo


Yes Yes Yes IMT
Yes Yes Yes Yes
No No Yes Not specified
Abdominal, pediatric Abdominal, pediatric Abdomen, TCD, QLAB 3DQ, 2DQ,
perinatology, SQ, ROI, MVI,
OB/GYN, pediatric, urology
musculoskeletal,
pediatric general
imaging, small parts,
urology, 2-D
quantification,
cardiac and general
imaging 3-D
quantification, M-
mode, IMT, fetal
heart quantification,
cardiac
speckle/strain, mitral
valve, ROI,
panoramic, stress,
elastography,
microvascular

User-configurable User-configurable User-configurable 20 per exam type


protocols protocols protocols

Yes Yes Yes Yes

No No Yes Yes
No No Yes No

Single, 17" high Single, 17" high Single, 21.5" high- Single, 20.4" LCD flat
definition monitor definition monitor definition widescreen, screen
TFT/IPS display, fully
articulating

Yes Yes Singe/dual/quad Yes

100-240 V, 50/60 Hz, 100-240 V, 50/60 Hz, 100-240 V, 50/60 Hz 100/120, 220/240
450 VA 450 VA VAC, 50/60 Hz

[131.5-148.3] x 52 x [136.1-151.9] x 52 x [146-171.5] x 60.6 x [151.1-173.9] x 53.3


58.4 ([41.8-58.4] x 58.4 ([53.6-59.8] x 109.2 ([57.5-67.5] x x 110.5 ([51-58] x 21
20.5 x 23 20.5 x 23 23.9 x 43) x 40)

52 (115) 52 (115) 104.3 (230) 100 (220)


$25,000-50,000 $35,000-60,000 $100,00-250,000 $70,000-120,000
1 year 1 year 1 year 1 year

Not specified Not specified Not specified Not specified

Weighs 25% less, Weighs 25% less, 25% less power None specified
reduces energy 60%, reduces energy 60%, consumption than
reduces disposable reduces disposable iE33 and iU22,
materials 11%, materials 11%, European Union
reduces packaging reduces packaging Restriction of
20% by 20% Hazardous
Substances (RoHS)
compliant
iScan (2-D); iScan (2-D, Color, Independent SonoCT real-time
trapezoid imaging; and Doppler); articulation; SonoCT compound imaging;
anatomic M-mode; trapezoid imaging; and XRES; XRES processing;
High Q, black and panoramic; anatomic PureWave transducer adjustable LCD with
white printer; XRES M-mode; High Q; technology; nSIGHT articulating arm;
processing; Physio SonoCT; black and beamformer QLAB lightweight
ECG. white printer; XRES quantification tools transducers;
processing; Physio for 2-D/3-D, IMT, anatomic M-mode; 2-
ECG. ROI, speckle D; 3-D; 4-D, STIC,
tracking, mitral valve MPR, iSlice; iSCAN
navigation, all one-control
electronic xMatrix optimization; High Q
transducer auto Doppler
technology, live 3-D analysis.
TEE transducer.

15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052

June 2014 June 2014 June 2014 June 2014


Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare
North America North America North America North America
HD15 HD7 XE HD9 iU22

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Not specified Not specified Yes
Abdominal, breast, Abdominal, breast, Abdominal, breast, Abdominal, breast,
cardiology, cardiology, cardiology, cardiology,
endocavity, endocavity, endocavity, endocavity,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
OB/GYN, pediatric, OB/GYN, pediatric, OB/GYN, pediatric, OB/GYN, pediatric,
prostate, regional prostate, regional prostate, regional prostate, regional
anesthesia, small anesthesia, small anesthesia, small anesthesia, small
parts, surgical, TCD, parts, surgical, TCD, parts, surgical, TCD, parts, surgical, TCD,
vascular vascular vascular vascular

L15-7io, L12-5, L12-3 15-6L, L12-5, L12-3 L12-5, L9-3 L17-5, L15-7io, L12-
5, L9-3, L8-4

C9-4, C8-5, C6-3, C8-5, C8-4v, C6-3, C9-4ec, C8-5, C8-4v, C9-4, C9-5sec, C8-5,
C5-2, C5-1 E6509, C5-2 C6-3, C5-2 C8-4v, C5-2, C5-1
PureWave, C10-3v
PureWave, V6-2,
3D9-3v
S8-3, S7-2t S5-2 S8, S4-2, S12, S7- S4-2 S7-2omni, S5-1
PureWave 2omni PureWave, S4-1

Broadband, optional Broadband Broadband, optional Broadband, optional


2-D 2-D 2-D
C8-4v C8-4v C8-4v, C9-4ec C8-4v, 3D9-3v

BP10-5ec C8-4v, C9-4ec C9-4ec C9-5ec

Not specified Not specified Not specified Not specified


D2cwc D1914c, D5009V D2cwc, D5cwc Static CW Doppler

Not specified Not specified Not specified X6-1 xMATRIX, X3-1


xMATRIX, X7-2
xMATRIX, PW
Doppler, VL13-5

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes NA Yes Yes
Yes NA NA 4-D and live volume

Multivariate Multivariate Multivariate Multivariate


PW, steerable CW, PW, steerable CW, PW, steerable CW, PW, steerable CW,
CFM, color power CFM, color power CFM, color power CFM, color power
angio, HPRF, TDI angio, HPRF, TDI angio, HPRF, TDI angio, HPRF, TDI

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Automatic iFOCUS
Yes Yes Yes Yes
No No No No

HD zoom HD zoom HD zoom HD zoom

Yes Yes Yes Yes


Internal HD, DVD, Internal HD, DVD, Internal HD, DVD, Internal HD, DVD,
CD, USB CD, USB CD, USB CD, USB

250 GB for data 500 GB system hard 140 GB for patient 160 GB for data
storage disk capacity data storage

1,000 frames 1,000 frames 5,000 frames in 2-D ≤10 min digital
capture

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

Stress echo Stress echo Yes Stress echo


IMT Yes Yes IMT
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
QLAB, 3DQ, 2DQ, Pediatric, urology Radiology, urology QLAB, 3DQ, 2DQ,
ROI, MVI, SQ, TMQ ROI, MVI, SQ, TMQ
radiology, cardiology, radiology, cardiology,
urology urology

40 per transducer 5 per clinical Not specified 40 per transducer


application

Yes Yes Yes Yes

Yes Yes Yes Yes


No No No No

Single, 20.4" LCD flat Single, LCD flat Single, LCD flat Single, 22"
screen screen screen widescreen LCD flat
screen

Yes Yes Yes Yes

100/120, 220/240 100/120, 220/240 100/120, 220/240 100/120, 220/240


VAC, 50/60 Hz VAC, 50/60 Hz VAC, 50/60 Hz VAC, 50/60 Hz

[138-155] x 57 x 110 [131.1-148.3] x 55 x 127.8 x 51 x 88.5 (51 [139-162] x 56 x 109


([54.3-61] x 22.4 x 102.4 ([51.8-58.4] x x 20.4 x 35.4) ([55-64] x 22 x 43)
43.5) 21.6 x 40.3)

100 (220) 75 (165) 101 (222) 156.5 (345)


$95,000-120,000 $35,000-60,000 $60,000-80,000 $150,000-300,000
1 year 1 year 1 year 1 year

Not specified Not specified Not specified Not specified

None specified None specified Reduced energy Weighs 22% less,


consumption by 18% eliminates 82% of
and packaging mercury, reduces
material weight by energy 37%, uses
25%, the percentage 20% less packaging,
of the product which offers a 30%
can be recycled improvement in
increased by 15% for weight of recyclable
a total life cycle material
assessment
improvement of 2%
SonoCT real-time Trapezoid imaging, Trapezoid imaging; iCOMMAND voice
compound imaging; panoramic, panoramic; control; SonoCT real-
XRES processing; moveable, rotatable lightweight time compound
tilt/swivel LCD; control panel; transducers; imaging; XRES
lightweight adjustable LCD with anatomic M-mode; 2- processing;
transducers; articulating arm, D, 3-D, 4-D STIC, adjustable monitor
anatomic M-mode; 2- stress echo, 3-D MPR, iSlice; iSCAN and control panel;
D; 3-D; iSCAN one- imaging/data one control one-control image
control optimization; management and optimization; High Q optimization; 2-D; 3-
High Q auto Doppler reporting; tissue auto Doppler D; 4-D, MPR, STIC;
analysis, trapezoid, harmonic imaging, analysis. iSlice; Live Volume;
panoramic; contrast; iSlice, and xPlane;
SmartExam workflow iSCAN one-control SmartExam workflow
protocols. optimization, High Q protocols;
auto Doppler AutoDoppler;
analysis. Vascular Plaque;
quantification; Fetal
Heart Navigator.

15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,


15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052

June 2014 June 2014 June 2014 June 2014


Philips Healthcare Samsung Medison Samsung Medison Samsung Medison
North America America Inc America Inc America Inc
Sparq ACCUVIX-XG SONOACE R5 SONOACE R7

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Regional anesthesia, Abdominal, breast, Abdominal, breast, Abdominal, breast,
pain management, cardiology, extremity, cardiology, extremity, cardiology, extremity,
emergency medicine, general, neonatal, general, neonatal, general, neonatal,
critical care, TEE OB/GYN, pediatric, OB/GYN, pediatric, OB/GYN, pediatric,
renal, surgery, renal, surgery, renal, surgery,
urology, vascular urology, vascular urology, vascular

L12-4 L3-8, L5-13IS, LF5- LN5-12, LN5-12/40, L3-8, HL5-12ED, L5-


12, LS5-13 LN5-12/60 12/50EP

C6-2 C1-4EC, C2-6IC C2-8, CN2-8 C2-8

S4-2 P2-4BA, P3-8CA, P4- Not specified P2-4AH


12CA

Broadband All probes All probes All probes

C9-4v VR5-9, EV4-9/10ED EVN4-9 EV4-9/10ED

Not specified ER4-9/10ED EC4-9 ER4-9/10ED

X7-2t Not specified Not specified Not specified


Not specified 2 CW, 4 CW Not specified Not specified

None specified C4-9/10ED, 3DC2-6, C2-4/20, CN4-9 3DC2-6, 3DC4-8ET


3DV4-8, 3DV5-9,
3DV6-12

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
No Yes Yes Yes
No Yes No Yes
No Yes No Yes

Multivariate Yes Yes Yes


PW, steerable CW, PW, CW, color PW, color PW, CW, color
color power angio, Doppler/power Doppler/power Doppler/power
HPRF, TDI, color Doppler imaging with Doppler Doppler imaging with
Doppler quad-beam receiving quad-beam receiving

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No No No No

HD zoom Yes Yes Yes

No Yes Yes Yes


Internal HD, CD, Built-in CD/DVD, Built-in CD/DVD, Built-in CD/DVD,
DVD, USB external USB flash, external USB flash, external USB flash,
external USB MO external USB MO external USB MO
drive, cine, SonoView drive, cine, SonoView drive, cine, SonoView

320 GB 500 GB HD; 250,000 160 GB HD; 80,000 250 GB HD; 100,000
images images images

1,000 frames 5,400 511 7,084

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
No Not specified Not specified Not specified
Cardiac Yes Yes Yes
measurements and
calculations, OB/GYN
measurements and
calculations,
abdominal

User-configurable Yes Yes Yes


protocols

Yes Yes Yes Yes

No Yes Yes Yes


No Yes Yes Yes

Single, 17" high 19" LCD high 15" LCD high 17" LCD high
definition monitor resolution monitor, 9" resolution resolution
touchscreen

Yes Dual and Quad view Dual Dual

100-240 V, 50/60 Hz, 110/220 VAC, 50/60 110/220 VAC, 50/60 110/220 VAC, 50/60
500 VA Hz Hz Hz

[82.6-111] x 53.3 x 134 x 54 x 88.5 (52.7 134 x 45 x 70 (52.7 x 134 x 45 x 70 (52.7 x


63.5 ([32.5-43.7] x 21 x 21.2 x 34.8) 17.7 x 27.5) 17.7 x 27.5)
x 25)

66.2 (146) 106.6 (235) 52 (114) 61 (134.5)


$50,000-100,000 Not specified Not specified Not specified
1 year 1 year 1 year 1 year

Not specified Depends on location Depends on location Depends on location

Packaging weight None specified None specified None specified


reduced 25%, energy
consumption reduced
50%, product weight
reduced 17%,
recyclability of
system improved by
10%
AutoScan; CPU card including CPU card including CPU card including
cleanability of UI; Pentium Core 2 Duo Geode Processor; Pentium Core 2 Duo
height adjustment; Processor; DDR2 512 MB main Processor; DDR2
needle visualization. SDRAM 4 GB main memory; SDRAM 4 GB main
memory; DVI/LAN/sound memory;
DVI/LAN/sound functions; 5 USB DVI/LAN/sound
functions; 6 USB ports; image filing; functions; 5 USB
ports; image filing; 3- digital beamformer; ports; image filing; 3-
D color; digital trapezoidal mode; 3 D color; digital
beamformer; probe ports. beamformer;
trapezoidal mode; 3 trapezoidal mode; 3
probe ports; STIC. probe ports.

15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,


15976, 16241, 18052 15976, 16241 15976, 16241 15976, 16241

June 2014 July 2011 July 2011 July 2011


Samsung Medison Siemens Medical Siemens Medical Siemens Medical
America Inc Solutions USA Inc Solutions USA Inc Solutions USA Inc
SONOACE X6 ACUSON Antares ACUSON S2000 ACUSON X150
Ultrasound Platform

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Abdominal, breast, Abdominal, breast, Abdominal, Abdominal,
cardiology, extremity, cardiac imaging, cardiology, cardiology, early
general, neonatal, endorectal, echocardiography obstetrics,
OB/GYN, pediatric, endovaginal, (adult, pediatric, musculoskeletal,
renal, surgery, intraoperative, neonatal), OB/GYN,
urology, vascular musculoskeletal, endorectal, orthopedics, renal,
neonatal, OB/GYN, endovaginal, small parts, vascular
pediatric, renal, small intraoperative,
parts, stress echo, musculoskeletal,
transcranial, urology, neonatal, OB/GYN,
vascular renal, small parts,
transcranial, urology,
vascular

HL5-12ED, L5- 4-1, 10-4, 13-5, 9-4, 4-9, 6-14, 6-18 13-5, 10-5, 9-5
12/50EP 10-5, 7-3

C3-7ED, C4-9ED 6-2, 4-1, 7-2, 5-1 1.5-4.5, 3.75-9, 2.5-6 5-2

P2-4AH, CW2M, 1-4.21, 1.54-4, 2.5-8 1-4, 2-4.5, 3-8, 4-10 4-2, 8-4
CW4M

All probes All transducers All transducers All transducers

NEV4-9ES, NER4- 9-4 3.75-9 5-8


9ES
Not specified 9-4 3.75-9 5-8

Not specified Multiplane TEE Multiplane TEE Not specified


Not specified 5, 2.1, 2 CW Doppler 2 and 5 CW Doppler Not specified
pencils pencil, 2.5-7

Not specified 5-1; 7-2 fourSight 4-D 4-9 fourSight 4-D; 5- None
transducers; 7-3 14 intraoperative
intraoperative

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
No Yes Yes Not specified
No Yes Yes Not specified

Yes Yes Yes Yes


PW, CFM PW, CW, HPRF, PW, CW, HPRF, PW, color Doppler,
color Doppler, power color Doppler velocity power Doppler, 2-D,
Doppler, M-mode, (CDV), color Doppler M-mode
color Doppler M- energy (power), M-
mode, DTI mode, color Doppler
M-mode, DTI

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No Yes No Yes

Read zoom/write Yes Yes Yes


zoom
Yes Yes Yes Yes
Built-in CD/DVD, DIMAQ-IP DIMAQ-IP DIMAQ-IP
external USB flash, workstation workstation workstation CD-RW,
external USB MO CD-R/DVD-R, S-VHS CD-R/DVD-R, DVR S-VHS VCR, DICOM,
drive, cine, SonoView VCR, DICOM, syngo record, DICOM, syngo Dynamics
Dynamics syngo Dynamics
35,000 images 80 GB; ≤32,000 1.5 TB; >606,350 ≤120,000; 40 GB
images images

511 200 MB 200 MB 545 frames

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

No Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Urology, renal, Urology, renal, Urology, testes,
transcranial, breast, transcranial, breast, thyroid, orthopedic
testes, thyroid, auto testes, thyroid,
Doppler trace and abdomen, auto
calculations Doppler trace and
calculations

Not specified >100 >100 ≤32

Yes Yes Yes Yes

Yes Yes Yes Yes


No No No No

Dual LCD Single, 19" flat-panel Single, 19" flat-panel Single, 15" flat-panel
LCD with in-plane LCD with in-plane LCD, articulating arm
switching technology switching technology
and articulating arm and articulating arm

Dual, quad SonoView Dual Dual, live dual Dual

110/220 VAC, 50/60 98-132/90-110/196- 98-132/90-110/196- 100-120/200-240


Hz 264 VAC, 50/60 Hz, 264 VAC, 50/60 Hz, VAC, 50/60 Hz, 600
1,200 VA 1,200 VA VA

138 x 48.3 x 69.1 [147-132] x 61 x 92 [147-132] x 61 x 92 136 x 52 x 85 (53.5 x


(54.3 x 19 x 27.2) ([58-52] x 24 x 36) ([58-52] x 24 x 36) 20 x 33.5)

60.8 (134) 159 (350) 159 (350) 93 (205)


Not specified Not specified Not specified Not specified
1 year 1 year 1 year 1 year

Depends on location Not specified Not specified Not specified

None specified None specified Standby power None specified


CFM; DICOM 3.0; MISA beam- 2-D and tissue All-digital
freehand 3-D; image formation technology; harmonic imaging architecture;
filing. precision upsampling; (THI); Advanced synthetic aperture
GigaProcessing SieClear spatial technology; digital
technology; high- compounding; color dynamic receive
density active Doppler velocity; focusing; Hanafy lens
aperture; channel-to- color Doppler energy; transducer
signal architecture; M-mode; M-mode technology; barcode
ErgoDynamic design; and THI; M-mode scanner.
syngo software; color and color Doppler
SieScape panoramic velocity; PW and CW
imaging; patented Doppler; Advanced
phase inversion fourSight technology;
technology; cadence Axius direct
contrast pulse ultrasound research
sequencing interface; Cadence
technology option; 3- contrast agent
Scape real-time 3-D imaging technology;
imaging; Advanced Cadence contrast
SieClear pulse sequencing
compounding with (CPS) technology;
dynamic tissue Clarify vascular
contrast enhancement (VE)
enhancement technology; color
technology; TEQ SieScape panoramic
technology for 2-D imaging; DTI Doppler
and spectral Doppler; tissue imaging
extend technology, capability; Dynamic
eSie Touch elasticity TCE tissue contrast
imaging, Fatty Tissue enhancement
Imaging (FTI), technology; eSie
Amnioscopic Touch elasticity
rendering, fourSight imaging; Fatty Tissue
4-D imaging; Imaging (FTI);
fourSight EV9F4 4-D fourSight 4-D
endovaginal transducer
transducer; fourSight technology; SieClear
ViewTool offline multi-view spatial
analysis; Clarify compounding;
vascular SieScape panoramic
enhancement imaging; syngo Auto
technology; ECG; OB measurements;
arterial health syngo Auto Left
package with IMT; Heart (Auto LH);
15657, 15957, velocity vector
15657, 15957, syngo
15657,eSieCalcs
15957, 15657, 15957,
15976, 16241 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052

July 2011 July 2011 July 2011 July 2011


Siemens Medical Toshiba America Toshiba America Toshiba America
Solutions USA Inc Medical Systems Medical Systems Medical Systems
ACUSON X300 Inc Inc Inc
Aplio 300SE Aplio 500 Xario 200

Worldwide Worldwide Worldwide Worldwide

Yes Yes Yes Yes


Yes Yes Yes Yes
Abdominal, Abdominal, Abdominal, Abdominal,
cardiology, cranial, cardiology, general- cardiology, general- cardiology, general
early obstetrics, purpose, purpose, purpose,
emergency medicine, interventional, interventional, interventional,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
OB/GYN, OB/GYN, small parts, OB/GYN, small parts, OB/GYN, small parts,
orthopedics, prostate, urology, vascular urology, vascular urology, vascular
renal, small parts,
urology, vascular

13-5, 10-5, 10-3 10-4 (vascular), 11-5 10-4 (vascular), 11-5 10-4 (vascular), 11-5
(carotid), 14-5 (small (carotid), 14-5 (small (carotid), 14-5 (small
parts), 18-7 (small parts), 18-7 (small parts), 18-7 (small
parts, MSK), 6-3 parts, MSK), 6-3 parts, MSK), 6-3
(abdominal biopsy) (abdominal biopsy) (abdominal biopsy)

8-5, 5-2 10-3 (pediatric), 6-2 10-3 (pediatric), 6-2 10-3 (pediatric), 6-2
(abdomen), 11-4 (abdomen), 6-1 (abdomen), 6-1
(neonatal head, (abdomen), 11-4 (abdomen), 11-4
pediatric abdomen) (neonatal head, (neonatal head,
pediatric abdomen) pediatric abdomen)
4-2 3-2 (TCD), 4-2 (adult 3-2 (TCD), 4-2 (adult 3-2 (TCD), 4-2 (adult
heart), 5-2 (adult heart), 5-2 (adult heart), 5-2 (adult
heart), 6-3 (pediatric heart), 6-3 (pediatric heart), 6-2
heart), 6-2 heart), 6-2 (abdomen), 9-4
(abdomen), 9-4 (abdomen), 9-4 (neonatal head)
(neonatal head) (neonatal head)

All transducers Yes All multifrequency Yes


probes
9-4 3-11 3-11 3-11

9-4 10-5 (biplane) 10-5 (biplane) 10-5 (biplane)

Not specified Adult multiplane TEE Adult multiplane TEE Adult multiplane TEE
(8-2), pediatric TEE (8-2), pediatric TEE (8-2)
(7-3) (7-3)
2 CW Doppler pencil 2 MHz, 5 MHz 2 MHz, 5 MHz 2 MHz, 5 MHz

Not specified 4-D volume imaging Dynamic microslice 4-D volume imaging
for radiology, 1.5 D array (6-2), 4-D for radiology,
intraoperative volume imaging for intraoperative
radiology,
intraoperative

256 256 256 256


Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes No No No
Not specified No No No
Not specified Yes Yes Yes

Yes Yes Yes Yes


PW, color Doppler, PW, CW, pencil CW, PW, CW, pencil CW, PW, CW, pencil CW,
power Doppler, steerable CW, CDI, steerable CW, CDI, steerable CW, CDI,
directional power power, advanced power, advanced power, advanced
Doppler, CW, DTI, 2- dynamic flow, TDI dynamic flow, Superb dynamic flow, TDI
D, M-mode Microvascular
Imaging, TDI

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes

Yes Yes Yes Yes

Yes Yes Yes Yes


DIMAQ-IP HDD, CD, DVD, HDD, CD, DVD, HDD, CD, DVD,
workstation DICOM, USB DICOM, USB DICOM, USB
CD-R/RW,
DVD-R/RW, DICOM,
syngo Dynamics
≤95,780; 80 GB 320 GB HDD x 2, 320 GB HDD x 2, 500 GB HDD, 175
≤87,000 images ≤87,000 images GB
(HDD) (HDD)
2,729 frames ≤4,095 ≤4,095 ≤4,095

Yes Yes Yes Yes


Not specified Not specified Not specified Not specified

Yes Yes Yes Yes


Yes Yes Yes Yes
Yes Yes Yes Yes
Optional Not specified Not specified Yes
Urology, breast, Gall bladder, Gall bladder, Gall bladder,
testes, thyroid, common bile duct, common bile duct, common bile duct,
orthopedic, optional liver, pancreas, liver, pancreas, liver, pancreas,
stress echo imaging kidney, spleen, 2-D kidney, spleen, kidney, spleen,
wall motion tracking, prostate, prostate,
prostate, elastography, 2-D elastography, user-
elastography, user- wall motion tracking, programmable
programmable user-programmable calculations
calculations calculations

≤32 Unlimited Unlimited Unlimited

Yes Yes Yes Yes

No Yes Yes Yes


No No No No

Single, 15" flat-panel 19" LCD with handle 19" LCD with handle 19" LCD with handle
LCD with in-plane
switching technology
and articulating arm

Dual Yes Yes Yes

100-120/200-240 100-120/220-240 100-120/220-240 100-120/220-240


VAC, 50/60 Hz, 600 VAC, 50/60 Hz VAC, 50/60 Hz VAC, 50/60 Hz
VA

138 x 52 x 88 (54 x [134.1-173.8] x 518 x [139-179] x 58.4 x [130.5-169.9] x 47.3


20 x 35) 879 ([52.8-68.4] x [89-101] ([54.7-70.5] x 78.5 ([51.4-66.9] x
20.4 x 34.6) x 23 x [35-39.8]) 18.6 x 30.9)

102 (225) 125 (275) 145 (319) 75 (165)


Not specified Not specified Not specified Not specified
1 year 1 year 1 year 1 year

Not specified 30 days 30 days 30 days

Standby power Reduced power Reduced power Reduced power


consumption, uses consumption, uses consumption, uses
recycled materials for recycled materials for recycled material for
construction and construction and construction and
packaging; meets packaging, meets packaging; meets
Toshiba's ECP Toshiba's ECP Toshiba's ECP
standard standard standard
All-digital Differential-THI; pulse Differential THI; pulse Differential-THI; pulse
architecture; TGO subtraction THI; subtraction THI; subtraction THI;
system optimization ApliPure+; trapezoid ApliPure+; trapezoid ApliPure+; trapezoid
technology; Clarify scan; Quick Scan; scan; Quick Scan; scan; Quick Scan;
vascular QuickAssist QuickAssist QuickAssist
enhancement Protocols; QuickStart protocols; QuickStart Protocols; QuickStart
technology; SieClear presets; advnanced presets; advanced presets, advanced
multiview spatial dynamic flow; dynamic flow; dynamic flow;
compounding; panoramic view; TDI; panoramic view; TDI; panoramic view; TDI;
Dynamic TCE tissue stress echo, 4-D stress echo; 4-D 4-D volume imaging
contrast volume imaging volume imaging package for
enhancement package for package; MicroPure; radiology;
technology, syngo radiology; MicroPure; elastography; auto- elastography; auto-
auto OB elastography; auto- IMT; precision IMT; precision
measurements, IMT; precision imaging, Dynamic imaging; Vascularity
SynAps synthetic imaging; Vascularity MicroSlice, Index; iSTYLE
aperture technology; Index, iSTYLE Vascularity Index; customizable control
Hanafy lens customizable control CT/MR/UL fusion, console and TCS.
technology; DTO console and TCS. FlyThru Technology;
dynamic tissue ISTYLE customizable
optimization; arterial control console and
health package with TCS.
IMT; Axius-assisted
ejection fraction,
barcode scanner; 50
minutes battery
powered scanner.

15657, 15957, 15976 15976 15976


15976, 16241, 18052

March 2010 July 2014 July 2014 July 2014


ZONARE Medical ZONARE Medical
Systems Inc Systems Inc
z.one ultra ZS3

Worldwide Worldwide

Yes Yes
Yes Yes
Anesthesiology, ED, OB, pediatric,
cardiology, ED, OB, radiology, shared
pediatric, radiology, services, vascular
vascular

3-14 3-20

2-9 10-3

1-10 1-10

Yes Yes

4-9 4-9

4-9 4-9

Not specified Yes


Not specified Not specified

Not specified None specified

256 256
ZST Sound Speed ZST Sound Speed
Comp Comp
Auto gain/DGC Yes

Yes Yes
Yes Yes
Yes No
Yes Yes
Yes No

Yes Yes
Color, power, PW, Color, power, PW,
CW, auxiliary CW CW

Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes

Yes Yes
Yes Yes
Yes Yes
Yes Yes
No No

Yes Yes

Yes Yes
Not specified Not specified

1,000,000 >1,000,000

≤300 sec ≤300 sec;


retrospective imaging
parameters available

Yes Yes
Not specified Not specified

Yes Yes
Yes Yes
Yes Yes
Not specified Not specified
Abdominal, arterial, Abdominal, arterial,
pediatric, hip pediatric, hip

Not specified Not specified

Not specified Not specified

Yes Yes
Yes Yes

Scan engine 14.7 cm 48 cm (19") high


(5.8") high-resolution resolution color LCD
color LCD; SmartCart mounted on
48 cm (19") high- articulating arm
resolution color LCD

Yes Yes

100-120/220-240 100-120/220-240
VAC, 50/60 Hz VAC, 50/60 Hz

7.3 x 25 x 25 (2.9 x [128-157] x 51 x 72


9.8 x 9.8); SmartCart: ([50.5-62] x 20.1 x
[128-160] x 51.1 x 28.2)
71.6 ([50.5-63] x 20.1
x 28.2)

2.49 (5.5); 57 (125) 66 (147)


SmartCart
$50,000-100,000 $105,000-150,000
1 year 5 years

Not specified 90 days

Reduces heat Reduces heat


generation, generation,
decreases decreases
greenhouse gas greenhouse gas
emissions, requires emissions, requires
fewer natural fewer natural
resources, recycling resources, recycling
plan meets plan meets
requirements of requirements of
Waste Electrical and Waste Electrical and
Electrical Equipment Electrical Equipment
(WEEE) directive (WEEE) directive
Convertible None specified.
ultrasound system
instantly converts
from a full-featured,
cart-based system
(SmartCart) to a 2.5
kg (5.5 lb) premium
compact ultrasound
system (scan
engine).

15976 15657, 15957,


15976, 16241, 18052

February 2013 August 2014