Manufacturer Esaote SpA Esaote SpA Esaote SpA
MyLab Seven MyLab Six MyLab Twice
WHERE MARKETED Worldwide Worldwide Worldwide
FDA CLEARANCE Yes Yes Yes
CE MARK (MDD) Yes Yes Yes
CLINICAL APPLICATIONS Cardiac (adult, Cardiac (adult, Cardiac (adult,
pediatric), vascular, pediatric), vascular, pediatric), vascular,
OB/GYN, general OB/GYN, general OB/GYN, general
imaging (adult, imaging (adult, imaging (adult,
neonatal, pediatric), neonatal, pediatric), neonatal, pediatric),
abdominal, cephalic abdominal, cephalic abdominal, cephalic
(adult, neonatal), (adult, neonatal), (adult, neonatal),
breast, breast, breast,
musculoskeletal, musculoskeletal, musculoskeletal,
pediatric, small parts, pediatric, small parts, pediatric, small parts,
thyroid, thyroid, urology thyroid,
intraoperative/interve intraoperative/interve
ntional, urology ntional, urology
PROBE TYPES, MHz
Linear array 3-18 3.3-18 3.3-22
Convex array 1-8 Not specified Not specified
Phased/vector array 1-8 1-10 1-10
Multifrequency All All probes All probes
Endovaginal Yes Not specified Not specified
Endorectal Yes Not specified Not specified
TEE Yes Not specified Not specified
CW Yes Pedoff and pencil Pedoff and pencil
CW Doppler CW Doppler
Others Volumetric Endocavity, Endocavity,
intraoperative, intraoperative,
microconvex, microconvex,
volumetric, volumetric,
laparoscopic, laparoscopic,
transesophageal, transesophageal,
1.8-18 all 1.8-18 all
multifrequency multifrequency,
probes for point-of-
care unit include
functional buttons,
ultra-high frequency
22 MHz
GRAYSCALE LEVELS 256 256 256
PREPROCESSING Yes Yes Yes
POSTPROCESSING Yes Yes Yes
IMAGING MODES
M-mode display Yes Yes Yes
M-mode and 2-D Yes Yes Yes
3-D (freehand) Noncardiac only Noncardiac only Noncardiac only
3-D (automatic) Not specified Not specified Not specified
4-D (live 3-D) Noncardiac only Noncardiac only Noncardiac only
Harmonic imaging Yes Yes Yes
DOPPLER
Type Color, power, Velo- Color, power, Velo- Color, power, Velo-
power, Xflow, PW, power, Xflow, PW, power, Xflow, PW,
CW CW CW
Frequency display Not specified Not specified Not specified
Velocity display Yes Yes Yes
Power Doppler Yes Yes Yes
Duplex mode Yes Yes Yes
Triplex mode Yes Yes Yes
FUNCTIONALITY
Digital calipers Yes Yes Yes
Selectable dynamic range Yes Yes Yes
Adjustable transmit focus Yes Yes Yes
Dynamic receive focus Yes Yes Yes
Measurements on video Not specified Not specified Yes
replay
PAN/ZOOM
Real-time image Yes Yes Yes
Frozen image Yes Yes Yes
IMAGE STORAGE Not specified Not speecified Not specified
Capacity, number of stored 250 GB HD 250 GB HD 250 GB HD
images
Cine ≤1,000 frames ≤1,000 frames ≤5,000 frames
DICOM 3.0 COMPLIANT Yes Yes Yes
PHYSIOLOGIC DATA Not specified ECG ECG
ANALYSIS PACKAGES
Cardiac scanning No Yes Yes
Vascular scanning Yes Yes Yes
OB/GYN scanning Yes Yes Yes
Stress echo Yes Yes Yes
Others Standard calculation Standard calculation Standard calculation
packages for: packages for: packages for:
Abdomen, breast, Abdomen, breast, Abdomen, breast,
cardiology, cardiology, cardiology,
gynecology, obstetric gynecology, obstetric gynecology, obstetric
with programmable with programmable with programmable
tables, pediatric, tables, pediatric, tables, pediatric,
small parts, thyroid, small parts, thyroid, small parts, thyroid,
transcranial, urology, transcranial, urology, transcranial, urology,
vascular standard vascular, standard vascular, standard
biometry reports and biometry reports and biometry reports and
user programmable user programmable user programmable
reports, generic reports, generic reports, generic
measurements, measurements, measurements,
NUMBER OF USER- Two different Two different Two different
PROGRAMMABLE accounts: accounts: accounts:
PROTOCOLS andministrator and andministrator and andministrator and
user; multiple users, user; multiple users, user; multiple users,
login by user, no limit login by user, no limit login by user, no limit
for programmable for programmable for programmable
protocols protocols protocols
USER-PROGRAMMABLE Yes Not specified Not specified
FORMULAS AND TABLES
NEEDLE GUIDES
Transrectal Yes Yes Yes
Transperineal Yes No Yes
MONITOR Single, 43.2 cm (17") Single 43.2 cm (17") Single, 48.2 cm (19")
LCD, 22.6 cm(8.9") or 48.2 cm (19") HD high resolution LCD,
LCD touchscreen LCD, 22.6 cm (8.9") 22.6 cm (8.9") LCD
LCD touchscreen touchscreen
SPLIT SCREEN Yes Yes Yes
POWER REQUIREMENTS 110/220, 50/60 Hz; 110/220, 50/60 Hz 110/220, 50/60 Hz
system standby
battery
H x W x D, cm (in) [122-143] x 49 x 70 [139-151] x 61 x 65 [148-155] x 63 x 102
([49-58] x 18 x 29) ([54-59] x 24 x 25.5) ([58-61] x 25 x 40)
WEIGHT, kg (lb) 65 (143) 55 (121) 100 (220)
PURCHASE INFORMATION
List price Not specified Not specified Not specified
Warranty 1-5 years 1-5 years 1-5 years
Delivery time, ARO Not specified Not specified Not specified
GREEN FEATURES Not specified Not specified Not specified
OTHER SPECIFICATIONS Reports stored Reports stored Reports stored
automatically in automatically in automatically in
patient file; for patient file. patient file; optional
advanced cardiac 2-in-1 satellite system
users. for added point-of-
care imaging while
freeing main system
for in-depth studies.
UMDNS CODE(S) 15976 15976 15976
LAST UPDATED October 2014 October 2014 October 2014
Supplier Footnotes
Model Footnotes
Data Footnotes
Fukuda Denshi Co Fukuda Denshi Co GE Healthcare USA GE Healthcare USA
Ltd Ltd LOGIQ E9 LOGIQ P5
UF-760 0AG UF-870AG
Worldwide Worldwide, except Worldwide Worldwide
USA
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, Abdominal, Abdominal, breast, Abdominal, breast,
cardiology, OB/GYN, cardiology, OB/GYN, intraoperative, cardiac, endocavity,
small parts, urology, small parts, urology, musculoskeletal, musculoskeletal,
vascular vascular OB/GYN, orthopedic, neontal, OB/GYN,
pediatric and pediatricl, small parts,
neonatal, peripheral, transcranial,
transcranial, urological, vascular
urological, vascular
5-12 5-12 9L-D, 11L-D, ML6- 8L, 9L, 10L, 11L,
15-D, RSP6-16-D 12L, i12L
2-5, 4-9 2-5, 4-9 C1-5-D, M6C-D, 3.5C, 4C, 5CS, 8C,
3CRF E8C, E8CS, BE9C
1-5, 2-5, 3-8 1-5, 2-5, 3-8 S1-5, M4S-D 3S, 5S, 7S, 3Sp, 5Sp
Yes Yes Yes All probes
3-8 4-7 IC5-9-D, RIC5-9-D E8C, E8CS, 4DE7C
NA No IC5-9-D E8C, E8CS, 4DE7C,
BE9CS
Not specified Not specified Not specified Not specified
Not specified Not specified Not specified P6D, P2D
Volume probe 3-6, Volume probe 3-6 Not specified 4D8C, 4D3C-L,
finger probe 5-12 4D5C-L, I739, T739,
ERB
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Including raw data
stored images
Yes Yes Yes Yes
Yes Yes Not specified Yes
No No Not specified Yes
Optional Optional Yes Yes
Optional Optional Yes Yes
Yes Yes Yes Yes
CW, PW CW, PW PW, PDI, color flow PW-HPRF, CWD,
mode PDI
Yes Yes Not specified Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Not specified Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Yes (viewing)
Yes Yes Yes Yes
Yes Yes Yes Yes
CD-R, HDD, printer, CD-R, HDD, printer, CD, DVD, HD, USB HD, DVD-R, CD-R,
USB, VCR USB, VCR videotape, USB
memory stick
160 GB 160 GB 40 GB HDD, 28 GB 40 GB HDD, 28 GB
images images
Yes Yes Not specified 970 frames, ≤60 sec
(192 MB)
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Optional Optional Not specified Not specified
NA None specified M-mode, B-mode, OB/GYN, urological,
Doppler calculations renal, fetal trending,
hip
Not specified Not specified Yes Extensive
OB/GYN, cardiac OB/GYN, cardiac Yes Yes
No No Not specified Yes
No No Not specified Yes, with ERB probe
Single Single Not specified Single 38.1 cm (15")
LCD monitor with
articulating arm
Yes Yes Not specified Yes
110-240 VAC 110-240 VAC 10% Not specified 100-120/220-240
VAC, 50/60 Hz, ≤750
VA
9.8 x 37 x 36 (3.9 x [132-151] x 48 x 83 141 x 58.4 x 83 (55.5 [135-141] x 43 x 64
14.6 x 14.2) ([52-59.4] x 18.9 x x 23 x 32.7) ([49-58] x 17 x 25)
32.7)
6.9 (15.2) 100 (220) Not specified 75 (165)
Not specified Not specified Not specified $45,000
1 year 1 year 1 year 1 year
Not specified 30 days Not specified 2-4 weeks
None specified None specified None specified None specified
None specified. Xtrillion digital-beam- Volume navigation; Raw data; coded
forming chip real-time ultrasound excitation; SRI;
technology provides with CT, MR, CrossXBeam; virtual
underlying foundation ultrasound images; convex; LOGIQView;
for high frame rates, customizable Scan B-flow; ECG option;
high-definition Assistant; raw data; storage drawer; TEE;
imaging, and power assisted TVI and Q-analysis;
increased axial control panel; pulsatile flow
resolution in the XT articulating LCD arm detection; B-steer.
and XTD ultrasound and lightweight
product lines. transducers.
15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052
August 2014 August 2014 July 2011 June 2014
GE Healthcare USA GE Healthcare USA GE Healthcare USA GE Healthcare USA
LOGIQ P6 LOGIQ S7 LOGIQ S8 Voluson E6
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, breast, Abdominal, Abdominal, Abdominal, breast,
cardiac, endocavity, anesthesia, breast, anesthesia, breast, cardiology,
musculoskeletal, cardiac, MSK, cardiac, MSK, neurological,
neonatal, OB/GYN, neonatal, OB/GYN, neonatal, OB/GYN, OB/GYN, orthopedic,
pediatric, small parts, pediatric, pediatric, pediatric and
transcranial, rheumatology, small rheumatology, small neonatal, small parts,
urological, vascular parts, vascular parts, vascular transcranial, urology,
vascular
8L, 9L, 11L, i12L 9L-D (2-8), 11L-D 9L-D (2-8), ML6-15-D SP10-16-D, 11L-D,
(4.2-12), ML6-15-D (4-15 matrix) 9L-D, RSP6-16-D
(4-15 matrix)
4C, 5CS, 8C, E8C, C1-5-D (1.8-5), 8C C1-5-D (1.8-5), 4C-D, C1-5-D, RAB6-
E8CS, BE9C (3.6-10 microconvex) 3CRF-D D, C4 8-D
3S, 5S, 7S, 3Sp, 5Sp 3Sp-D (1.6-5.5), S4- M5S-D, S4-10-D 3S-D
10-D (3.6-10)
All probes Yes Yes Yes
E8C, E8CS, 4DE7C IC5-9-D (3.6-9 IC5-9-D (3.6-9) end- IC5-9-D, RIC5 9-D
microconvex) fire
E8C, E8CS, 4DE7C, IC5-9-D (3.6-9 IC5-9-D (3.6-9) end- IC5-9-D
BE9CS microconvex) fire
6T P2D (2), P6D (6) Not specified Not specified
P6D, P2D Not specified Not specified Yes
4D3C, 4D5C, I739, L8-18i (5-18 hockey L8-18i-D (5-18 Not specified
T739, ERB stick) hockey stick)
256 256 256 256
Yes Yes Yes Yes
Including raw data Yes Yes Yes
stored images
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Not specified
Yes Yes Yes Yes
Yes Yes No Yes
Yes Yes Yes Yes
PD, PW, CW PW, CW, CDI, PDI PW, CDI, PDI PW-HPRF, CW, PD,
color flow TD, HD
flow
Yes Yes Yes Not specified
Yes Yes Yes Not specified
Yes Yes Yes Not specified
Yes Yes Yes Not specified
Yes Yes Yes Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes (viewing) Yes, DVR Yes, DVR Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
HD, DVD-R, CD-R, Not specified Not specified CD-R, DVD, USB
videotape, USB
memory stick
80 GB HDD, 65 GB Not specified 160 GB HDD 112 GB 280 GB HDD
images
1,200 frames, ≤60 Not specified 891.3 ≤256 MB, ≤8,000 2-D
sec (192 MB) images
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
OB/GYN, urological, Not specified Not specified M-mode, B-mode,
renal, fetal trending, Doppler calculations
hip
Extensive Not specified Not specified Yes
Yes Not specified Not specified Yes
Yes Yes Yes Not specified
No Not specified No Not specified
Single 43.2 cm (17") Single 48.3 cm (19") Single 48.3 cm (19") 48.3 cm (19'')
LCD monitor with LCD with articulating LCD with articulating noninterlaced, high
articulating arm arm arm resolution
Yes Yes Yes Yes
100-120/220-240 Not specified 100-120 or 220-240 100-130/220-240,
VAC, 50/60 Hz, ≤750 VAC 50/60 Hz, ≤1,010 VA
VA
[125-147] x 43 x 64 Not specified [175-115.1] x 58.4 x 129 x 58 x 93 (50.8 x
([49-58] x 17 x 25) 82.6 ([68.9-45.3] x 23 22.8 x 36.6)
x 32.5)
80 (176) Not specified 85 (187.4) 120 (265)
$85,000 $161,440<1> $232,799<1> Not specified
1 year Not specified Not specified Upon request
1-2 weeks Not specified Not specified Not specified
None specified None specified None specified None specified
Raw data; coded Platform is highly Coded harmonic STIC; multiplanar
excitation; SRI-HD; configurable; optional imaging; LOGIQView modes; VCI;
CrossXBeam; virtual scan assistant; (extended FOV); B- SonoVCAD;
convex; LOGIQView; CrossXBeam; multi- Flow, AutoEF (semi- SonoAVC; Scan
B-flow; ECG option; modality query automatic Assistant; floating
storage drawer; TEE; retrieve; B-Flow; B- measurement of user interface;
TVI and Q-analysis; Steer and needle ejection fraction); electrical height
pulsatile flow recognition; volume Scan Assistant; adjustment; raw data.
detection; B-steer. imaging. CrossXBeam; OB
Measure Assistant;
breast and thyroid
productivity
packages; wireless;
raw data (allows
measurements and
image adjustments
after image
acquisition); Power
Assistant;
elastography; Auto
IMT.
15657, 15957, 15976 15976 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052
June 2014 July 2014 July 2014 July 2014
<1>Pricing <1>Pricing
information derived information derived
from ECRI Institute's from ECRI Institute's
PricePaid database. PricePaid database.
GE Healthcare USA GE Healthcare USA GE Healthcare USA GE Healthcare USA
Voluson E8 Expert Voluson P8 Voluson S6 Voluson S8
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, breast, Abdominal, breast, Abdominal, breast, Abdominal, breast,
cardiology, OB/GYN, orthopedic, OB/GYN, orthopedic, OB/GYN, orthopedic,
musculoskeletal, pediatric and pediatric and pediatric and
OB/GYN, orthopedic, neonatal, small parts, neonatal, small parts, neonatal, small parts,
pediatric and urology, vascular urology, vascular urology, vascular
neonatal, small parts,
transcranial, urology,
vascular
SP10-16-D, 9L-D, 12L-R5 12L-RS 12L-RS
11L-D, RSP6-16-D,
RSM5-14
4C-D, C1-5-D, C4-8- 4C-RS, RAB2-6-RS 4C-RS, RAB2-6-RS C1-5-RS, 4C-RS,
D, RAB6-D, RM6C-d RAB6-RS
3S-D Not specified Not specified Not specified
Yes Yes Yes Yes
IC5-9-D, RIC5-9-D, E8C-RS, RICS-9W- E8C-RS, RIC5-9W- E8C-RS, RIC5-9W-
RIC6-12 RS RS RS
IC5-9-D E8C-RS, RICS-9W- E8C-RS, RIC5-9W- E8C-RS, RIC5-9W-
RS RS RS
Not specified Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Not specified Not specified Not specified Not specified
256 256 256 256
Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Not specified Not specified Not specified
No Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Color, tissue, PD, PW-HPRF, PD, HD PW-HPRF, PD, HD PW-HPRF, PD, HD
CW, PW with HPRF, flow, color flow TD flow, color flow TD flow, color flow TD
HD flow
Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Yes Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
HD, MOD, CD-RW, CD-R, DVD, USB CD-R, DVD, USB CD-R, DVD, USB
DVD, USB
280 GB HD 120 GB HDD 120 GB HDD 120 GB HDD
≤256 MB, ≤8,000 2-D ≤256 MB, ≤8,000 2-D ≤256 MB, ≤8,000 2-D ≤256 MB, ≤8,000 2-D
images images images images
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
M-mode, B-mode, M-mode, B-mode, M-mode, B-mode, M-mode, B-mode,
Doppler calculations Doppler calculations Doppler calculations Doppler calculations
Extensive Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Not specified Not specified Not specified Not specified
48.3 cm (19'') 38.1 cm (15'') 48.3 cm (19'') 48.3 cm (19")
noninterlaced, high noninterlaced, high noninterlaced, high
resolution resolution resolution
Yes Not specified Not specified Not specified
100-130/220-240 100-130/220-240 100-130/220-240 100-130/220-240
VAC, 50/60 Hz, VAC, 50/60 Hz, VAC, 50/60 Hz, VAC, 50/60 Hz,
≤1,010 VA ≤1,010 VA ≤1,010 VA ≤1,010 VA
129 x 57.9 x 93 (50.8 Not specified [97.5-172.5] x 62 x [97.5-172.5] x 62 x
x 22.8 x 36.6) 84.8 ([38.4-67.9] x 84.8 ([38.4-67.9] x
24.4 x 33.4) 24.4 x 33.4)
120 (265) Not specified Not specified Not specified
Not specified Not specified Not specified Not specified
Upon request Upon request Upon request Upon request
30-60 days Not specified Not specified Not specified
None specified None specified None specified None specified
Real-time 4-D; real- Auto optimization; Auto optimization; Auto optimization;
time 4-D biopsy; Scan Assistant; raw VCI; SonoVCAD; STIC; multiplanar;
volume calculation data; floating user Scan Assistant; raw multiple rendering
(VOCAL); volume interface. data; floating user modes; OmniView;
contrast imaging interface. VCI; SonoVCAD;
(VCI); SonoVCAD, SonoAVC; Scan
SonoAVC, coded Assistant; raw data;
harmonic imaging floating user
(THI); compound interface.
resolution imaging
(CRI); tissue color
Doppler imaging; 4-D
fetal cardio (STIC);
coded excitation
(CE); auto
optimization
frequency and focus
composite (FFC); B-
flow; virtual convex;
RSP biopsy kit;
DICOM print, store,
worklist, lossy JPEG,
3-D rotation/4-D as
DICOM MF, batch
print/send, spooler,
simultaneous
worklist/local archive.
15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052
July 2014 August 2014 August 2014 August 2014
Hitachi Aloka Hitachi Aloka Hitachi Aloka Hitachi Aloka
America America America America
Arietta 70 Hi Vision Preirus Noblus ProSound Alpha 6
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Radiology, Radiology, Radiology, Breast, interventional
cardiology, vascular, interventional cardiology, urology, radiology,
TEE radiology, OB/GYN, interventional musculoskeletal,
vascular, breast, radiology, OB/GYN, OB/GYN, radiology,
small parts, vascular, breast, small parts, urology,
musculoskeletal small parts, vascular
musculoskeletal,
brachytherapy
3-18 3-18 3-18 4.4-15
1-5 1-10 1-10 2-10
1-9 2-9 1-9 3-8
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes No Yes
Yes Yes Yes Yes
Not specified Pediatric transrectal, Intercostal offset Linear array robotic
through-crystal biopsy, through surgery, 4-way
biopsy guidance, crystal biopsy laparoscopic, End-
neonatal micro- guidance, bi-plane Fire laparoscopic,
convex, offset transrectal, hockey burr-hole guidance,
intercostal convex, stick, 360 degree micro-surgery
linear-hockey stick, pediatric and adult guidance, Hockey-
200 degree field-of- transrectal, 150 Stick linear array,
view micro-convex degree 4-D linear array rigid
endocavity endocavity, single laparoscopic, narrow-
crystal pediatric, 200 view Side-Fire “T”,
degree end-fire linear array 2-way
prostate biopsy laparoscopic, linear
array side-fire “T”,
curved array “I” style
finger-grip, curved
array “T” style finger-
grip, ranial guidance
transducer
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
PW, steerable CW, PW, CW, HPRF-PW, PW, CW, HPRF-PW, PW, CW, HPRF-PW,
HPRF-PW, tissue tissue doppler, Dual tissue Doppler, Dual tissue Doppler, Dual
Doppler, Dual Gate Gate doppler, Fine Gate Doppler, Fine Gate Doppler, D-
Doppler, D-eFlow FLOW FLOW eFLOW
Yes Yes Yes Yes
Yes Yes Yes Yes
Directional Directional Directional Directional
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
HDD, DVD-RAM, HDD, DVD-RAM, HDD, DVD-RAM, HDD, DVD-RAM,
CD-R, USB memory, CD-R, USB memory, CD-R, USB memory, CD-R, USB memory,
USB HDD, PACS USB HDD, PACS USB HDD, PACS USB HDD, PACS
72,000 ~72,000 ~63,000 <150,000 static
images
Not specified Not specified 19,000 frames Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes No Yes
Contrast Echo, General General, urology, Urological
automated segmental musculoskeletal, measurements and
pediatric, small parts calculations,
brachytherapy grid
display, Real-time
Multi-Free Angular M-
Mode
100 22 22 45
Yes Yes Yes Yes
Yes No Yes Yes
No No Yes No
Single Single Single Single
Yes Yes Yes Yes
100-120/200 to 240 V 100/110, 120, 220- 120/240 V, 60 Hz 115/220-240 VAC,
±10%, 50/60 Hz 240 V ±10%, 50/60 50/60 Hz
Hz
[130-175] x 53.5 x 79 [135-1550] x 45 x [112.5-132.6] x 52.1 [130-155] x 42 x 70
([51.2-68.9] x 21.1 x [90-110] ([53-61] x x 51.8 ([44.3-52.2] x ([51-61] x 16.5 x
31.1) 17.7 x [35.4 x 43.3]) 20.5 x 20.4) 27.6)
117 (258) main unit 190 (419) 40 (88.2) 70 (156)
only
Not specified $130,720 $60,000 $101,900
1 year 1 year 1 year 1 year
30-45 days 30-45 days 30-45 days 30-45 days
Not specified None specified None specified None specified
Elastography; Real- Elastography, Real- Power consumption Dual Dynamic
time Virtual time Virtual is only 250 W (550 W Display (DDD).
Sonography (RVS); Sonography (RVS). using cart);
eTRACKING; wave removable console
intensity; Dual contains an internal
Dynamic Display battery allowing
(DDD); Dynamic examinations to be
Slow-motion Display performed even
(DSD). when an external
power source is not
available; supports
wireless LAN for
DICOM
communication.
15657, 15957, 15976 15976 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052
June 2014 June 2014 June 2014 June 2014
Hitachi Aloka Hitachi Aloka Hitachi Aloka Hologic Inc
America America America Aixplorer MultiWave
ProSound Alpha 7 ProSound F37 ProSound F75 Ultrasound System
Worldwide Worldwide Worldwide USA
Yes Yes Yes Yes
Yes Yes Yes Yes
Brachytherapy, Breast, Breast, interventional Abdominal, breast,
breast, cardiology, muscoloskeletal, radiology, endorectal,
musculoskeletal, OB/GYN, radiology, musculoskeletal, endovaginal,
neurosurgery, small parts OB/GYN, radiology, genitourinary,
OB/GYN, radiology, small parts, TEE, musculoskeletal,
small parts, TEE, urology, vascular pediatric, pelvic,
urology, vascular renal, thyroid,
vascular
3-13.3 5-13 2.5-13.33 4-15, 2-10
1.5-13 2-7.5 1.3-10 1-6
1-8 No No NA
Yes Yes Yes Yes
Yes Yes Yes 3-12
Yes Yes Yes 3-12
Yes Yes Yes NA
Yes Yes Yes NA
Pediatric TEE, Not specified Pediatric TEE, 3-D (5-16),
neonatal sector through-crystal microconvex (3-12)
array, linear array biopsy guidance
robotic surgery,
curved array 4-way
laparoscopic, Linear
array 4-way
laparoscopic, linear
array rigid
laparoscopic, phased
array burr-hole, End-
Fire laparoscopic,
linear array micro-
surgery, flexible
linear array, Hockey-
Stick linear array,
narrow-view Side-
Fire “T”, linear array
side-fire “T”, linear
array 2-way
laparoscopic, 60mm
linear, cranial
guidance, curved
array “I” style finger-
grip, curved array “T”
style
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes NA
Yes Yes Yes 2-D
Yes Yes Yes NA
Yes Yes No Yes
Yes Yes Yes NA
Yes Yes Yes Yes
PW, CW, HPRF-PW, PW, CW, HPRF-PW, PW, CW, HPRF-PW, CFI, CPI, dCPI, PW,
tissue Doppler, Dual tissue Doppler, Dual tissue Doppler, Dual UltraFast Doppler
Gate Doppler, D- Gate Doppler, D- Gate Doppler, D-
eFLOW eFLOW eFLOW
Yes Yes Yes Yes
Yes Yes Yes Yes
Directional Directional Directional Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
HDD, DVD-RAM, HDD, DVD-RAM, HDD, DVD-RAM, Not specified
CD-R, USB memory, CD-R, USB memory, CD-R, USB memory,
USB HDD, PACS USB HDD, PACS USB HDD, PACS
<150,000 static <150,000 static <150,000 static >20,000
images images images
~20,000 frames 12,800 frames 61,450 frames ≤3 min @ 30 fps
Yes Yes Yes Yes
Yes Yes Yes Heart rate calculated
from PW Doppler or
M-mode
Yes Yes Yes No
Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Yes Yes No
Contrast echo, Fetal growth analysis, Urological Breast BI-RADS,
automated Real-time Multi-Free measurements and thyroid Thy-RADS,
segmental, motion Angular M-Mode calculations, small abdominal, renal,
analysis, flow parts measurements pelvic, genitourinary,
mediated, dilatation and calculations, musculoskeletal,
analysis, TDI abdominal vascular, pediatric
analysis, Real-time measurements and
Multi-Free Angular M- calculations, Real-
Mode time Multi-Free
Angular M-Mode
45 45 45 NA
Yes Yes Yes Yes
Yes Yes No Yes
Yes No No Yes
Single Single Single Single, 21.5" LCD
Yes Yes Yes Yes
115/200 to 240 V 100-120/200-240 V 115/200 to 240 V 100-120 VAC, 50/60
±10%, 50/60 Hz ±10%, 50/60 Hz ±10%, 50/60 Hz Hz, 1,500 W; 220-
240 VAC, 50/60 Hz
[142-173] x 49 x 79 [130-155] x 42 x 70 [120-168] x 59 x 100 [131-169] x 61 x 105
([56-68] x 19.3 x ([51.2 x 61] x 16.5 x ([47.2-66.1] x 23.2 x ([51-67] x 24 x 41)
31.1) 27.5) 39.4)
108 (238) 65 (143) 170 (375) 97 (214)
$119,000 $32,600 $137,900 $142,000
1 year 1 year 1 year 1 year
30-45 days 30-45 days 30-45 days 30-45 days
None specified None specified None specified None specified
Elastography; remote Dual Dynamic Remote control; Dual Ergonomic cart;
control; Dual Display (DDD). Dynamic Display optimized presets for
Dynamic Display (DDD); Dynamic all clinical
(DDD); Dynamic Slow-motion Display applications; user
Slow-motion Display (DSD); eTracking, customizable presets;
(DSD); eTracking, Wave Intensity. Tissue Tuner; Shear
wave intensity. Wave Elasto;
SonicSoftware
Beamforming and
Scan Conversion;
Ultrafast Doppler
Imaging; Integrated
Touch Screen with
TouchRing and Track
Ball; Interactive Picto
Body Markers;
annotations
packages; full post-
processing in review.
15657, 15957, 15976 15976 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052
June 2014 June 2014 June 2014 August 2014
Mindray Medical Mindray Medical Mindray Medical Mindray Medical
International Ltd International Ltd International Ltd International Ltd
DC 7 DC-8 DC-N3 DC-T6
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, breast, Abdominal, breast, Abdominal, breast, Abdominal, breast,
cardiology, EM, cardiology, EM, cardiology, cardiology, EM,
endocavity, endocavity, endocavity, endocavity,
intraoperative, intraoperative, intraoperative, intraoperative,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
nerve, OB/GYN, nerve, OB/GYN, nerve, OB/GYN, nerve, OB/GYN,
orthopedic, pediatric, orthopedic, pediatric, orthopedic, prostate, orthopedic, pediatric,
prostate, small parts, prostate, small parts, small parts, urology, prostate, small parts,
TCI, urology, TCI, urology, vascular TCI, urology,
vascular vascular vascular
2-16 2.6-16 3.7-16 2-16
1.5-12 1.3-12.8 1.7-11.3 1.5-12
1.3-13.5 1.3-11.4 1.5-5 1.3-8
All transducers All transducers Al transducers All transducers
3.6-10 2.6-12.8 3.4-11 3.6-10
3-11 2.6-12.8 Not specified 3-11
3.5-13.5 3.1-8.2 Not specified 3.1-7.2
5 2 and 5 Not specified 2 and 5
Intraoperative Volume transducer Volume transducer Not specified
transducer, volume
transducer
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes No Yes
Yes Yes Yes Yes
PW/CW PW/CW PW/CW PW/CW
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
8 sets 8 sets 8 sets 8 sets
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
HD, USB, CD-RW HD, USB, DVD-RW, HD, flash memory, HD, USB, CD-RW
DVR USB, CD-RW
320 GB >800 GB or 113,664 270 GB 320 GB
frames
6,156 13,335 frame or 145 ≤12,392 frames or 1,024
sec (mode 169.6 sec
dependent)
Optional Optional Optional Optional
ECG ECG ECG ECG
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Yes
Abdominal, small Abdominal, small Abdominal, small Abdominal, small
parts, endocavity, parts, endocavity, parts, endocavity, parts, endocavity,
urology, prostate, urology, prostate, urology, prostate, urology, prostate,
breast, orthopedic, breast, orthopedic, breast, orthopedic, breast, orthopedic,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
nerve, intraoperative, nerve, intraoperative, nerve, intraoperative nerve, intraoperative,
pediatric, EM, TCI pediatric, EM, TCI pediatric, EM, TCI
Unlimited Unlimited Unlimited Unlimited
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Not specified Not specified Not specified
Single Single Single With external monitor
No No No No
110/220 VAC, 50/60 110/220 VAC, 50/60 110/220 VAC, 50/60 110/220 VAC, 50/60
Hz Hz Hz Hz
135 x 50 x 85 (53.1 x 136 x 59 x 93 (54 x 50 x 141.5 x 74 (19.7 46 x 73 x 129 (18.1 x
19.7 x 33.5) 23 x 37) x 55.7 x 29.1) 28.7 x 50.8)
120 (264.5) 111 (245) 62 (136.7) 95 (209)
Not specified Not specified Not specified Not specified
2 years, for unit from 1 year, for unit from 2 years from date of 2 years, for unit from
date of shipment, date of shipment, shipment, extensions date of shipment,
extensions available extensions available available extensions available
<1 week <1 week <1 week <1 week
None specified None specified None specified None specified
User customization of Elastography, User customization of User customization of
applications; multiple contrast imaging. applications; multiple applications; multiple
calculation packages Meets requirements calculation packages calculation packages
available. Meets of IEC 60601-1 and available. Meets available. Meets
requirements of IEC TUV. requirements of IEC requirements of IEC
60601-1 and TUV. 60601-1 and TUV. 60601-1 and TUV.
15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052
June 2014 June 2014 June 2014 June 2014
Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare
North America North America North America North America
ClearVue 350 ClearVue 550 EPIQ HD11 XE
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, Abdominal, Abdominal, OB/GYN, Abdominal, breast,
cardiology, cardiology, fetal, pediatric, TCD, cardiology,
musculoskeletal, musculoskeletal, breast, small parts, endocavity,
OB/GYN, pediatric, OB/GYN, pediatric, musculoskeletal, musculoskeletal,
small parts, TCD, small parts, TCD, prostate, renal, OB/GYN, pediatric,
urology, vascular urology, vascular bladder, contrast, prostate, regional
surgical, anesthesia, small
interventional, parts, surgical, TCD,
intraoperative, vascular
endocavity,
superficial, adult
echo, pediatric echo,
stress echo, fetal
echo, TEE
L12-4 L12-4 VL13-5, L18-5, L15- L15-7io, L12-5, L12-
7io, L12-5 50 mm, 3, L9-3, L8-4
L12-3
C5-2 C5-2 C9-2 PureWave, C8- C9-4, C8-5, C6-3,
5, C5-1 PureWave, C5-2/V6-2, V8-4,
V6-2 3D9-3v
S4-1 S4-1 X5-1 xMatrix S12-4, S8-3, S7-3t,
PureWave, X7-2 S7-2omni, S4-2, S3-1
xMatrix PureWave,
X6-1 xMatrix
PureWave,S12-4,
S8-3, S5-1
PureWave
Broadband Broadband Broadband with 2-D Broadband, optional
optimization 2-D
C9-4v C9-4v C10-3v PureWave, C8-4v, 3D9-3v
3D9-3v
Not specified Not specified C10-4ec BP10-5ec, C9-5ec
Not specified Not specified X7-2t TEE xMatrix Not specified
PureWave, S7-3t
TEE
Not specified Not specified 2, 5 nonimaging Static CW Doppler
None specified None specified 1 PW transcranial; 1 PW Doppler
endocavity, 2
endovaginal
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No No Yes Yes
No No Yes Yes
Multivariate Multivariate Multivariate including Multivariate
pulse inversion and
coded harmonics
PW, steerable CW, PW, steerable CW, PW, steerable CW, PW, steerable CW,
color Doppler, color color Doppler, color Live 3-D Echo, Live CFM, color power
power angio, HPRF power angio, HPRF xPlane, stress echo, angio, HPRF, TDI
contrast, iRotate,
XRES, SonoCT,
AutoScan, strain-
based and shear
wave elastography,
color power angio
imaging
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes iFocus Yes
Yes Yes Yes Yes
No No Yes No
HD zoom HD zoom HD zoom HD zoom
Yes Yes Yes Yes
Internal HD, CD, Internal HD, CD, Internal HD, DVD, Internal HD, DVD,
DVD, USB DVD, USB CD, USB CD, USB
320 GB for data 320 GB 1 TB 160 GB for data
storage storage
1,200 frames 1,200 frames 2,200 frames 1,000 frames
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Yes Yes Stress echo
Yes Yes Yes IMT
Yes Yes Yes Yes
No No Yes Not specified
Abdominal, pediatric Abdominal, pediatric Abdomen, TCD, QLAB 3DQ, 2DQ,
perinatology, SQ, ROI, MVI,
OB/GYN, pediatric, urology
musculoskeletal,
pediatric general
imaging, small parts,
urology, 2-D
quantification,
cardiac and general
imaging 3-D
quantification, M-
mode, IMT, fetal
heart quantification,
cardiac
speckle/strain, mitral
valve, ROI,
panoramic, stress,
elastography,
microvascular
User-configurable User-configurable User-configurable 20 per exam type
protocols protocols protocols
Yes Yes Yes Yes
No No Yes Yes
No No Yes No
Single, 17" high Single, 17" high Single, 21.5" high- Single, 20.4" LCD flat
definition monitor definition monitor definition widescreen, screen
TFT/IPS display, fully
articulating
Yes Yes Singe/dual/quad Yes
100-240 V, 50/60 Hz, 100-240 V, 50/60 Hz, 100-240 V, 50/60 Hz 100/120, 220/240
450 VA 450 VA VAC, 50/60 Hz
[131.5-148.3] x 52 x [136.1-151.9] x 52 x [146-171.5] x 60.6 x [151.1-173.9] x 53.3
58.4 ([41.8-58.4] x 58.4 ([53.6-59.8] x 109.2 ([57.5-67.5] x x 110.5 ([51-58] x 21
20.5 x 23 20.5 x 23 23.9 x 43) x 40)
52 (115) 52 (115) 104.3 (230) 100 (220)
$25,000-50,000 $35,000-60,000 $100,00-250,000 $70,000-120,000
1 year 1 year 1 year 1 year
Not specified Not specified Not specified Not specified
Weighs 25% less, Weighs 25% less, 25% less power None specified
reduces energy 60%, reduces energy 60%, consumption than
reduces disposable reduces disposable iE33 and iU22,
materials 11%, materials 11%, European Union
reduces packaging reduces packaging Restriction of
20% by 20% Hazardous
Substances (RoHS)
compliant
iScan (2-D); iScan (2-D, Color, Independent SonoCT real-time
trapezoid imaging; and Doppler); articulation; SonoCT compound imaging;
anatomic M-mode; trapezoid imaging; and XRES; XRES processing;
High Q, black and panoramic; anatomic PureWave transducer adjustable LCD with
white printer; XRES M-mode; High Q; technology; nSIGHT articulating arm;
processing; Physio SonoCT; black and beamformer QLAB lightweight
ECG. white printer; XRES quantification tools transducers;
processing; Physio for 2-D/3-D, IMT, anatomic M-mode; 2-
ECG. ROI, speckle D; 3-D; 4-D, STIC,
tracking, mitral valve MPR, iSlice; iSCAN
navigation, all one-control
electronic xMatrix optimization; High Q
transducer auto Doppler
technology, live 3-D analysis.
TEE transducer.
15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052
June 2014 June 2014 June 2014 June 2014
Philips Healthcare Philips Healthcare Philips Healthcare Philips Healthcare
North America North America North America North America
HD15 HD7 XE HD9 iU22
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Not specified Not specified Yes
Abdominal, breast, Abdominal, breast, Abdominal, breast, Abdominal, breast,
cardiology, cardiology, cardiology, cardiology,
endocavity, endocavity, endocavity, endocavity,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
OB/GYN, pediatric, OB/GYN, pediatric, OB/GYN, pediatric, OB/GYN, pediatric,
prostate, regional prostate, regional prostate, regional prostate, regional
anesthesia, small anesthesia, small anesthesia, small anesthesia, small
parts, surgical, TCD, parts, surgical, TCD, parts, surgical, TCD, parts, surgical, TCD,
vascular vascular vascular vascular
L15-7io, L12-5, L12-3 15-6L, L12-5, L12-3 L12-5, L9-3 L17-5, L15-7io, L12-
5, L9-3, L8-4
C9-4, C8-5, C6-3, C8-5, C8-4v, C6-3, C9-4ec, C8-5, C8-4v, C9-4, C9-5sec, C8-5,
C5-2, C5-1 E6509, C5-2 C6-3, C5-2 C8-4v, C5-2, C5-1
PureWave, C10-3v
PureWave, V6-2,
3D9-3v
S8-3, S7-2t S5-2 S8, S4-2, S12, S7- S4-2 S7-2omni, S5-1
PureWave 2omni PureWave, S4-1
Broadband, optional Broadband Broadband, optional Broadband, optional
2-D 2-D 2-D
C8-4v C8-4v C8-4v, C9-4ec C8-4v, 3D9-3v
BP10-5ec C8-4v, C9-4ec C9-4ec C9-5ec
Not specified Not specified Not specified Not specified
D2cwc D1914c, D5009V D2cwc, D5cwc Static CW Doppler
Not specified Not specified Not specified X6-1 xMATRIX, X3-1
xMATRIX, X7-2
xMATRIX, PW
Doppler, VL13-5
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes NA Yes Yes
Yes NA NA 4-D and live volume
Multivariate Multivariate Multivariate Multivariate
PW, steerable CW, PW, steerable CW, PW, steerable CW, PW, steerable CW,
CFM, color power CFM, color power CFM, color power CFM, color power
angio, HPRF, TDI angio, HPRF, TDI angio, HPRF, TDI angio, HPRF, TDI
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Automatic iFOCUS
Yes Yes Yes Yes
No No No No
HD zoom HD zoom HD zoom HD zoom
Yes Yes Yes Yes
Internal HD, DVD, Internal HD, DVD, Internal HD, DVD, Internal HD, DVD,
CD, USB CD, USB CD, USB CD, USB
250 GB for data 500 GB system hard 140 GB for patient 160 GB for data
storage disk capacity data storage
1,000 frames 1,000 frames 5,000 frames in 2-D ≤10 min digital
capture
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Stress echo Stress echo Yes Stress echo
IMT Yes Yes IMT
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
QLAB, 3DQ, 2DQ, Pediatric, urology Radiology, urology QLAB, 3DQ, 2DQ,
ROI, MVI, SQ, TMQ ROI, MVI, SQ, TMQ
radiology, cardiology, radiology, cardiology,
urology urology
40 per transducer 5 per clinical Not specified 40 per transducer
application
Yes Yes Yes Yes
Yes Yes Yes Yes
No No No No
Single, 20.4" LCD flat Single, LCD flat Single, LCD flat Single, 22"
screen screen screen widescreen LCD flat
screen
Yes Yes Yes Yes
100/120, 220/240 100/120, 220/240 100/120, 220/240 100/120, 220/240
VAC, 50/60 Hz VAC, 50/60 Hz VAC, 50/60 Hz VAC, 50/60 Hz
[138-155] x 57 x 110 [131.1-148.3] x 55 x 127.8 x 51 x 88.5 (51 [139-162] x 56 x 109
([54.3-61] x 22.4 x 102.4 ([51.8-58.4] x x 20.4 x 35.4) ([55-64] x 22 x 43)
43.5) 21.6 x 40.3)
100 (220) 75 (165) 101 (222) 156.5 (345)
$95,000-120,000 $35,000-60,000 $60,000-80,000 $150,000-300,000
1 year 1 year 1 year 1 year
Not specified Not specified Not specified Not specified
None specified None specified Reduced energy Weighs 22% less,
consumption by 18% eliminates 82% of
and packaging mercury, reduces
material weight by energy 37%, uses
25%, the percentage 20% less packaging,
of the product which offers a 30%
can be recycled improvement in
increased by 15% for weight of recyclable
a total life cycle material
assessment
improvement of 2%
SonoCT real-time Trapezoid imaging, Trapezoid imaging; iCOMMAND voice
compound imaging; panoramic, panoramic; control; SonoCT real-
XRES processing; moveable, rotatable lightweight time compound
tilt/swivel LCD; control panel; transducers; imaging; XRES
lightweight adjustable LCD with anatomic M-mode; 2- processing;
transducers; articulating arm, D, 3-D, 4-D STIC, adjustable monitor
anatomic M-mode; 2- stress echo, 3-D MPR, iSlice; iSCAN and control panel;
D; 3-D; iSCAN one- imaging/data one control one-control image
control optimization; management and optimization; High Q optimization; 2-D; 3-
High Q auto Doppler reporting; tissue auto Doppler D; 4-D, MPR, STIC;
analysis, trapezoid, harmonic imaging, analysis. iSlice; Live Volume;
panoramic; contrast; iSlice, and xPlane;
SmartExam workflow iSCAN one-control SmartExam workflow
protocols. optimization, High Q protocols;
auto Doppler AutoDoppler;
analysis. Vascular Plaque;
quantification; Fetal
Heart Navigator.
15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,
15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052
June 2014 June 2014 June 2014 June 2014
Philips Healthcare Samsung Medison Samsung Medison Samsung Medison
North America America Inc America Inc America Inc
Sparq ACCUVIX-XG SONOACE R5 SONOACE R7
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Regional anesthesia, Abdominal, breast, Abdominal, breast, Abdominal, breast,
pain management, cardiology, extremity, cardiology, extremity, cardiology, extremity,
emergency medicine, general, neonatal, general, neonatal, general, neonatal,
critical care, TEE OB/GYN, pediatric, OB/GYN, pediatric, OB/GYN, pediatric,
renal, surgery, renal, surgery, renal, surgery,
urology, vascular urology, vascular urology, vascular
L12-4 L3-8, L5-13IS, LF5- LN5-12, LN5-12/40, L3-8, HL5-12ED, L5-
12, LS5-13 LN5-12/60 12/50EP
C6-2 C1-4EC, C2-6IC C2-8, CN2-8 C2-8
S4-2 P2-4BA, P3-8CA, P4- Not specified P2-4AH
12CA
Broadband All probes All probes All probes
C9-4v VR5-9, EV4-9/10ED EVN4-9 EV4-9/10ED
Not specified ER4-9/10ED EC4-9 ER4-9/10ED
X7-2t Not specified Not specified Not specified
Not specified 2 CW, 4 CW Not specified Not specified
None specified C4-9/10ED, 3DC2-6, C2-4/20, CN4-9 3DC2-6, 3DC4-8ET
3DV4-8, 3DV5-9,
3DV6-12
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No Yes Yes Yes
No Yes No Yes
No Yes No Yes
Multivariate Yes Yes Yes
PW, steerable CW, PW, CW, color PW, color PW, CW, color
color power angio, Doppler/power Doppler/power Doppler/power
HPRF, TDI, color Doppler imaging with Doppler Doppler imaging with
Doppler quad-beam receiving quad-beam receiving
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No No No No
HD zoom Yes Yes Yes
No Yes Yes Yes
Internal HD, CD, Built-in CD/DVD, Built-in CD/DVD, Built-in CD/DVD,
DVD, USB external USB flash, external USB flash, external USB flash,
external USB MO external USB MO external USB MO
drive, cine, SonoView drive, cine, SonoView drive, cine, SonoView
320 GB 500 GB HD; 250,000 160 GB HD; 80,000 250 GB HD; 100,000
images images images
1,000 frames 5,400 511 7,084
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No Not specified Not specified Not specified
Cardiac Yes Yes Yes
measurements and
calculations, OB/GYN
measurements and
calculations,
abdominal
User-configurable Yes Yes Yes
protocols
Yes Yes Yes Yes
No Yes Yes Yes
No Yes Yes Yes
Single, 17" high 19" LCD high 15" LCD high 17" LCD high
definition monitor resolution monitor, 9" resolution resolution
touchscreen
Yes Dual and Quad view Dual Dual
100-240 V, 50/60 Hz, 110/220 VAC, 50/60 110/220 VAC, 50/60 110/220 VAC, 50/60
500 VA Hz Hz Hz
[82.6-111] x 53.3 x 134 x 54 x 88.5 (52.7 134 x 45 x 70 (52.7 x 134 x 45 x 70 (52.7 x
63.5 ([32.5-43.7] x 21 x 21.2 x 34.8) 17.7 x 27.5) 17.7 x 27.5)
x 25)
66.2 (146) 106.6 (235) 52 (114) 61 (134.5)
$50,000-100,000 Not specified Not specified Not specified
1 year 1 year 1 year 1 year
Not specified Depends on location Depends on location Depends on location
Packaging weight None specified None specified None specified
reduced 25%, energy
consumption reduced
50%, product weight
reduced 17%,
recyclability of
system improved by
10%
AutoScan; CPU card including CPU card including CPU card including
cleanability of UI; Pentium Core 2 Duo Geode Processor; Pentium Core 2 Duo
height adjustment; Processor; DDR2 512 MB main Processor; DDR2
needle visualization. SDRAM 4 GB main memory; SDRAM 4 GB main
memory; DVI/LAN/sound memory;
DVI/LAN/sound functions; 5 USB DVI/LAN/sound
functions; 6 USB ports; image filing; functions; 5 USB
ports; image filing; 3- digital beamformer; ports; image filing; 3-
D color; digital trapezoidal mode; 3 D color; digital
beamformer; probe ports. beamformer;
trapezoidal mode; 3 trapezoidal mode; 3
probe ports; STIC. probe ports.
15657, 15957, 15657, 15957, 15657, 15957, 15657, 15957,
15976, 16241, 18052 15976, 16241 15976, 16241 15976, 16241
June 2014 July 2011 July 2011 July 2011
Samsung Medison Siemens Medical Siemens Medical Siemens Medical
America Inc Solutions USA Inc Solutions USA Inc Solutions USA Inc
SONOACE X6 ACUSON Antares ACUSON S2000 ACUSON X150
Ultrasound Platform
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, breast, Abdominal, breast, Abdominal, Abdominal,
cardiology, extremity, cardiac imaging, cardiology, cardiology, early
general, neonatal, endorectal, echocardiography obstetrics,
OB/GYN, pediatric, endovaginal, (adult, pediatric, musculoskeletal,
renal, surgery, intraoperative, neonatal), OB/GYN,
urology, vascular musculoskeletal, endorectal, orthopedics, renal,
neonatal, OB/GYN, endovaginal, small parts, vascular
pediatric, renal, small intraoperative,
parts, stress echo, musculoskeletal,
transcranial, urology, neonatal, OB/GYN,
vascular renal, small parts,
transcranial, urology,
vascular
HL5-12ED, L5- 4-1, 10-4, 13-5, 9-4, 4-9, 6-14, 6-18 13-5, 10-5, 9-5
12/50EP 10-5, 7-3
C3-7ED, C4-9ED 6-2, 4-1, 7-2, 5-1 1.5-4.5, 3.75-9, 2.5-6 5-2
P2-4AH, CW2M, 1-4.21, 1.54-4, 2.5-8 1-4, 2-4.5, 3-8, 4-10 4-2, 8-4
CW4M
All probes All transducers All transducers All transducers
NEV4-9ES, NER4- 9-4 3.75-9 5-8
9ES
Not specified 9-4 3.75-9 5-8
Not specified Multiplane TEE Multiplane TEE Not specified
Not specified 5, 2.1, 2 CW Doppler 2 and 5 CW Doppler Not specified
pencils pencil, 2.5-7
Not specified 5-1; 7-2 fourSight 4-D 4-9 fourSight 4-D; 5- None
transducers; 7-3 14 intraoperative
intraoperative
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No Yes Yes Not specified
No Yes Yes Not specified
Yes Yes Yes Yes
PW, CFM PW, CW, HPRF, PW, CW, HPRF, PW, color Doppler,
color Doppler, power color Doppler velocity power Doppler, 2-D,
Doppler, M-mode, (CDV), color Doppler M-mode
color Doppler M- energy (power), M-
mode, DTI mode, color Doppler
M-mode, DTI
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No Yes No Yes
Read zoom/write Yes Yes Yes
zoom
Yes Yes Yes Yes
Built-in CD/DVD, DIMAQ-IP DIMAQ-IP DIMAQ-IP
external USB flash, workstation workstation workstation CD-RW,
external USB MO CD-R/DVD-R, S-VHS CD-R/DVD-R, DVR S-VHS VCR, DICOM,
drive, cine, SonoView VCR, DICOM, syngo record, DICOM, syngo Dynamics
Dynamics syngo Dynamics
35,000 images 80 GB; ≤32,000 1.5 TB; >606,350 ≤120,000; 40 GB
images images
511 200 MB 200 MB 545 frames
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
No Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Urology, renal, Urology, renal, Urology, testes,
transcranial, breast, transcranial, breast, thyroid, orthopedic
testes, thyroid, auto testes, thyroid,
Doppler trace and abdomen, auto
calculations Doppler trace and
calculations
Not specified >100 >100 ≤32
Yes Yes Yes Yes
Yes Yes Yes Yes
No No No No
Dual LCD Single, 19" flat-panel Single, 19" flat-panel Single, 15" flat-panel
LCD with in-plane LCD with in-plane LCD, articulating arm
switching technology switching technology
and articulating arm and articulating arm
Dual, quad SonoView Dual Dual, live dual Dual
110/220 VAC, 50/60 98-132/90-110/196- 98-132/90-110/196- 100-120/200-240
Hz 264 VAC, 50/60 Hz, 264 VAC, 50/60 Hz, VAC, 50/60 Hz, 600
1,200 VA 1,200 VA VA
138 x 48.3 x 69.1 [147-132] x 61 x 92 [147-132] x 61 x 92 136 x 52 x 85 (53.5 x
(54.3 x 19 x 27.2) ([58-52] x 24 x 36) ([58-52] x 24 x 36) 20 x 33.5)
60.8 (134) 159 (350) 159 (350) 93 (205)
Not specified Not specified Not specified Not specified
1 year 1 year 1 year 1 year
Depends on location Not specified Not specified Not specified
None specified None specified Standby power None specified
CFM; DICOM 3.0; MISA beam- 2-D and tissue All-digital
freehand 3-D; image formation technology; harmonic imaging architecture;
filing. precision upsampling; (THI); Advanced synthetic aperture
GigaProcessing SieClear spatial technology; digital
technology; high- compounding; color dynamic receive
density active Doppler velocity; focusing; Hanafy lens
aperture; channel-to- color Doppler energy; transducer
signal architecture; M-mode; M-mode technology; barcode
ErgoDynamic design; and THI; M-mode scanner.
syngo software; color and color Doppler
SieScape panoramic velocity; PW and CW
imaging; patented Doppler; Advanced
phase inversion fourSight technology;
technology; cadence Axius direct
contrast pulse ultrasound research
sequencing interface; Cadence
technology option; 3- contrast agent
Scape real-time 3-D imaging technology;
imaging; Advanced Cadence contrast
SieClear pulse sequencing
compounding with (CPS) technology;
dynamic tissue Clarify vascular
contrast enhancement (VE)
enhancement technology; color
technology; TEQ SieScape panoramic
technology for 2-D imaging; DTI Doppler
and spectral Doppler; tissue imaging
extend technology, capability; Dynamic
eSie Touch elasticity TCE tissue contrast
imaging, Fatty Tissue enhancement
Imaging (FTI), technology; eSie
Amnioscopic Touch elasticity
rendering, fourSight imaging; Fatty Tissue
4-D imaging; Imaging (FTI);
fourSight EV9F4 4-D fourSight 4-D
endovaginal transducer
transducer; fourSight technology; SieClear
ViewTool offline multi-view spatial
analysis; Clarify compounding;
vascular SieScape panoramic
enhancement imaging; syngo Auto
technology; ECG; OB measurements;
arterial health syngo Auto Left
package with IMT; Heart (Auto LH);
15657, 15957, velocity vector
15657, 15957, syngo
15657,eSieCalcs
15957, 15657, 15957,
15976, 16241 15976, 16241, 18052 15976, 16241, 18052 15976, 16241, 18052
July 2011 July 2011 July 2011 July 2011
Siemens Medical Toshiba America Toshiba America Toshiba America
Solutions USA Inc Medical Systems Medical Systems Medical Systems
ACUSON X300 Inc Inc Inc
Aplio 300SE Aplio 500 Xario 200
Worldwide Worldwide Worldwide Worldwide
Yes Yes Yes Yes
Yes Yes Yes Yes
Abdominal, Abdominal, Abdominal, Abdominal,
cardiology, cranial, cardiology, general- cardiology, general- cardiology, general
early obstetrics, purpose, purpose, purpose,
emergency medicine, interventional, interventional, interventional,
musculoskeletal, musculoskeletal, musculoskeletal, musculoskeletal,
OB/GYN, OB/GYN, small parts, OB/GYN, small parts, OB/GYN, small parts,
orthopedics, prostate, urology, vascular urology, vascular urology, vascular
renal, small parts,
urology, vascular
13-5, 10-5, 10-3 10-4 (vascular), 11-5 10-4 (vascular), 11-5 10-4 (vascular), 11-5
(carotid), 14-5 (small (carotid), 14-5 (small (carotid), 14-5 (small
parts), 18-7 (small parts), 18-7 (small parts), 18-7 (small
parts, MSK), 6-3 parts, MSK), 6-3 parts, MSK), 6-3
(abdominal biopsy) (abdominal biopsy) (abdominal biopsy)
8-5, 5-2 10-3 (pediatric), 6-2 10-3 (pediatric), 6-2 10-3 (pediatric), 6-2
(abdomen), 11-4 (abdomen), 6-1 (abdomen), 6-1
(neonatal head, (abdomen), 11-4 (abdomen), 11-4
pediatric abdomen) (neonatal head, (neonatal head,
pediatric abdomen) pediatric abdomen)
4-2 3-2 (TCD), 4-2 (adult 3-2 (TCD), 4-2 (adult 3-2 (TCD), 4-2 (adult
heart), 5-2 (adult heart), 5-2 (adult heart), 5-2 (adult
heart), 6-3 (pediatric heart), 6-3 (pediatric heart), 6-2
heart), 6-2 heart), 6-2 (abdomen), 9-4
(abdomen), 9-4 (abdomen), 9-4 (neonatal head)
(neonatal head) (neonatal head)
All transducers Yes All multifrequency Yes
probes
9-4 3-11 3-11 3-11
9-4 10-5 (biplane) 10-5 (biplane) 10-5 (biplane)
Not specified Adult multiplane TEE Adult multiplane TEE Adult multiplane TEE
(8-2), pediatric TEE (8-2), pediatric TEE (8-2)
(7-3) (7-3)
2 CW Doppler pencil 2 MHz, 5 MHz 2 MHz, 5 MHz 2 MHz, 5 MHz
Not specified 4-D volume imaging Dynamic microslice 4-D volume imaging
for radiology, 1.5 D array (6-2), 4-D for radiology,
intraoperative volume imaging for intraoperative
radiology,
intraoperative
256 256 256 256
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes No No No
Not specified No No No
Not specified Yes Yes Yes
Yes Yes Yes Yes
PW, color Doppler, PW, CW, pencil CW, PW, CW, pencil CW, PW, CW, pencil CW,
power Doppler, steerable CW, CDI, steerable CW, CDI, steerable CW, CDI,
directional power power, advanced power, advanced power, advanced
Doppler, CW, DTI, 2- dynamic flow, TDI dynamic flow, Superb dynamic flow, TDI
D, M-mode Microvascular
Imaging, TDI
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
DIMAQ-IP HDD, CD, DVD, HDD, CD, DVD, HDD, CD, DVD,
workstation DICOM, USB DICOM, USB DICOM, USB
CD-R/RW,
DVD-R/RW, DICOM,
syngo Dynamics
≤95,780; 80 GB 320 GB HDD x 2, 320 GB HDD x 2, 500 GB HDD, 175
≤87,000 images ≤87,000 images GB
(HDD) (HDD)
2,729 frames ≤4,095 ≤4,095 ≤4,095
Yes Yes Yes Yes
Not specified Not specified Not specified Not specified
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Optional Not specified Not specified Yes
Urology, breast, Gall bladder, Gall bladder, Gall bladder,
testes, thyroid, common bile duct, common bile duct, common bile duct,
orthopedic, optional liver, pancreas, liver, pancreas, liver, pancreas,
stress echo imaging kidney, spleen, 2-D kidney, spleen, kidney, spleen,
wall motion tracking, prostate, prostate,
prostate, elastography, 2-D elastography, user-
elastography, user- wall motion tracking, programmable
programmable user-programmable calculations
calculations calculations
≤32 Unlimited Unlimited Unlimited
Yes Yes Yes Yes
No Yes Yes Yes
No No No No
Single, 15" flat-panel 19" LCD with handle 19" LCD with handle 19" LCD with handle
LCD with in-plane
switching technology
and articulating arm
Dual Yes Yes Yes
100-120/200-240 100-120/220-240 100-120/220-240 100-120/220-240
VAC, 50/60 Hz, 600 VAC, 50/60 Hz VAC, 50/60 Hz VAC, 50/60 Hz
VA
138 x 52 x 88 (54 x [134.1-173.8] x 518 x [139-179] x 58.4 x [130.5-169.9] x 47.3
20 x 35) 879 ([52.8-68.4] x [89-101] ([54.7-70.5] x 78.5 ([51.4-66.9] x
20.4 x 34.6) x 23 x [35-39.8]) 18.6 x 30.9)
102 (225) 125 (275) 145 (319) 75 (165)
Not specified Not specified Not specified Not specified
1 year 1 year 1 year 1 year
Not specified 30 days 30 days 30 days
Standby power Reduced power Reduced power Reduced power
consumption, uses consumption, uses consumption, uses
recycled materials for recycled materials for recycled material for
construction and construction and construction and
packaging; meets packaging, meets packaging; meets
Toshiba's ECP Toshiba's ECP Toshiba's ECP
standard standard standard
All-digital Differential-THI; pulse Differential THI; pulse Differential-THI; pulse
architecture; TGO subtraction THI; subtraction THI; subtraction THI;
system optimization ApliPure+; trapezoid ApliPure+; trapezoid ApliPure+; trapezoid
technology; Clarify scan; Quick Scan; scan; Quick Scan; scan; Quick Scan;
vascular QuickAssist QuickAssist QuickAssist
enhancement Protocols; QuickStart protocols; QuickStart Protocols; QuickStart
technology; SieClear presets; advnanced presets; advanced presets, advanced
multiview spatial dynamic flow; dynamic flow; dynamic flow;
compounding; panoramic view; TDI; panoramic view; TDI; panoramic view; TDI;
Dynamic TCE tissue stress echo, 4-D stress echo; 4-D 4-D volume imaging
contrast volume imaging volume imaging package for
enhancement package for package; MicroPure; radiology;
technology, syngo radiology; MicroPure; elastography; auto- elastography; auto-
auto OB elastography; auto- IMT; precision IMT; precision
measurements, IMT; precision imaging, Dynamic imaging; Vascularity
SynAps synthetic imaging; Vascularity MicroSlice, Index; iSTYLE
aperture technology; Index, iSTYLE Vascularity Index; customizable control
Hanafy lens customizable control CT/MR/UL fusion, console and TCS.
technology; DTO console and TCS. FlyThru Technology;
dynamic tissue ISTYLE customizable
optimization; arterial control console and
health package with TCS.
IMT; Axius-assisted
ejection fraction,
barcode scanner; 50
minutes battery
powered scanner.
15657, 15957, 15976 15976 15976
15976, 16241, 18052
March 2010 July 2014 July 2014 July 2014
ZONARE Medical ZONARE Medical
Systems Inc Systems Inc
z.one ultra ZS3
Worldwide Worldwide
Yes Yes
Yes Yes
Anesthesiology, ED, OB, pediatric,
cardiology, ED, OB, radiology, shared
pediatric, radiology, services, vascular
vascular
3-14 3-20
2-9 10-3
1-10 1-10
Yes Yes
4-9 4-9
4-9 4-9
Not specified Yes
Not specified Not specified
Not specified None specified
256 256
ZST Sound Speed ZST Sound Speed
Comp Comp
Auto gain/DGC Yes
Yes Yes
Yes Yes
Yes No
Yes Yes
Yes No
Yes Yes
Color, power, PW, Color, power, PW,
CW, auxiliary CW CW
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
No No
Yes Yes
Yes Yes
Not specified Not specified
1,000,000 >1,000,000
≤300 sec ≤300 sec;
retrospective imaging
parameters available
Yes Yes
Not specified Not specified
Yes Yes
Yes Yes
Yes Yes
Not specified Not specified
Abdominal, arterial, Abdominal, arterial,
pediatric, hip pediatric, hip
Not specified Not specified
Not specified Not specified
Yes Yes
Yes Yes
Scan engine 14.7 cm 48 cm (19") high
(5.8") high-resolution resolution color LCD
color LCD; SmartCart mounted on
48 cm (19") high- articulating arm
resolution color LCD
Yes Yes
100-120/220-240 100-120/220-240
VAC, 50/60 Hz VAC, 50/60 Hz
7.3 x 25 x 25 (2.9 x [128-157] x 51 x 72
9.8 x 9.8); SmartCart: ([50.5-62] x 20.1 x
[128-160] x 51.1 x 28.2)
71.6 ([50.5-63] x 20.1
x 28.2)
2.49 (5.5); 57 (125) 66 (147)
SmartCart
$50,000-100,000 $105,000-150,000
1 year 5 years
Not specified 90 days
Reduces heat Reduces heat
generation, generation,
decreases decreases
greenhouse gas greenhouse gas
emissions, requires emissions, requires
fewer natural fewer natural
resources, recycling resources, recycling
plan meets plan meets
requirements of requirements of
Waste Electrical and Waste Electrical and
Electrical Equipment Electrical Equipment
(WEEE) directive (WEEE) directive
Convertible None specified.
ultrasound system
instantly converts
from a full-featured,
cart-based system
(SmartCart) to a 2.5
kg (5.5 lb) premium
compact ultrasound
system (scan
engine).
15976 15657, 15957,
15976, 16241, 18052
February 2013 August 2014