2 × 2.

0 mm² THHN
Cu. WIRE
GENERAL ELECTRICAL NOTES:
CEILING LINE
2 × 50 mm² THHN
Cu. WIRE
1. THE ELECTRICAL INSTALLATIONS SHOWN ON THE PLANS SHALL CONFIRM WITH THE LATEST
EDITION OF THE PHILIPPINE ELECTRICAL CODE, RULES AND REGULATIONS OF THE ELECTRICAL
COMPANY AND THE LOCAL GOVERNMENT WHERE THE PROJECT WILL BE CONSTRUCTED.
SWITCH LINE
2. ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE USED IN THE PROJECT SHALL BE BRAND-NEW
ISECO LP
(2-WIRE 230V SERVICE) 2 × 3.5 mm² THHN AND OF APPROVED QUALITY AND BRAND.
Cu. WIRE 3. ALL ELECTRICAL WIRING INSIDE THE BUILDING SHALL BE THROUGH PVC CONDUIT PIPES NOT
1.60m
SE 1.50m
SMALLER THAN 15 MM DIAMETER.
R.C. TERMINAL 4. THERE SHALL ONLY BE ONE SERVICE DROP FROM THE NEAREST ELECTRICAL COMPANY POLE TO
POST 0.40m
2F THE PROPOSED BUILDING. VERIFY LOCATION IN THE VICINITY MAP.
2 × 80 mm² THHN 5. WIRES TO BE USED FOR CONVENIENCE OUTLET INSIDE THE BUILDING SHALL NOT BE SMALLER
Cu. WIRE
CEILING LINE THAN 3.5 mm² WITH 600V INSULATION.
2 × 38 mm² THHN
Cu. WIRE 2 × 2.0 mm² THHN 6. SERVICE ENTRANCE AND SUB-FEEDER SHALL BE INSTALLED IN RIGID STEEL CONDUIT PIPE AND
Cu. WIRE
SHALL BE USED FOR INSTALLATION OF LIGHTS AND POWER.
M
7. JUNCTION AND PULL BOXES ON PROPER DIMENSION SHALL BE INSTALLED WHEN NECESSARY IF
SWITCH LINE
NOT SHOWN IN THE PLAN.
LP 8. ALL 15 AND 20 AMPERES HOMERUN WITH MORE THAN 30 METERS IN LENGTH SHALL BE 3.5 mm² AND
2 × 3.5 mm² THHN 5.5 mm² RESPECTIVELY UNLESS OTHERWISE SPECIFIED.
1.80m Cu. WIRE
1.60m
1.50m
9. MAXIMUM LOAD FOR EACH HOUSEHOLD LIGHTING OUTLET SHALL BE 100 WATTS. FOR EACH SINGLE
RECEPTACLE SHALL BE CONSIDERED AT NO LESS THAN 180 WATTS RATING.
0.40m 10. OTHER LOADS SHALL FOLLOW THE SPECIFIED REQUIREMENTS STATED FROM THE
GF APPLIANCES/EQUIPMENT.

LEGEND & SYMBOLS


CIRCULAR FLOURESCENT LAMP RANGE OUTLET AIRCONDITION UNIT OUTLET
R ACU S1 SINGLE GANG SWITCH
REFRIGERATOR OUTLET WATER HEATER OUTLET

SINGLE LINE DIAGRAM P


PIN LIGHT
REF

WP
WEATHER PROOF OUTLET
[Link]

[Link]
WASHING MACHINE OUTLET
S2
S3
TWO GANG SWITCH

THREE GANG SWITCH


PANEL BOARD WATER PUMP CIRCUIT BREAKER
[Link]
CIRCUIT HOMERUN
m SWITCH LINE
KILOWATT-HOUR METER SERVICE ENTRANCE CONDUCTOR
AF AMPERE FRAME
CIRCUIT LINE RUN INSIDE WALL OR OVER CEILING
CONVENIENCE OUTLET GROUND WIRE
AT AMPERE TRIP
CIRCUIT LINE RUN INSIDE WALL OR UNDER FLOOR
MCCB MOLDED CASE CIRCUIT BREAKER

COMPANY LOGO : STUDENT : ELECTRICAL ENGINEER : TITLE : SHEET CONTENTS : SHEET NO. :

ENGR. GEORGE P. ALONZO GENERAL ELECTRICAL NOTES

JC
JEAN CARLO P. PARBO PROFESSIONAL ELECTRICAL ENGINEER
BSSE 3-A PRC NO. : 3956

VALID UNTIL : 03-19-2025


PTR NO. : 6644847

DATE ISSUED : 12-06-2024


2 - STOREY HOUSE SINGLE LINE DIAGRAM
E-4
TIN : 155-458-611 ISSUED AT : VIGAN CITY LEGEND