Example of VFD Schematic
Example of VFD Schematic
-Q1
I
O
C C
D -FAN 1 -FAN 2 D
E E
30M
All devices shown in this diagram are in open position, drawn out, with operating mechanism discharged and all power source off.
disclosed without its prior written consent. Only those drawings and diagrams remitted after order booking are binding for execution.
All technical information contained in this document is the exclusive property of PT. SCHNEIDER INDONESIA may neither be used nor
F F
08/06/2018
Date 07/08/2018 Project Name Title Front Face & Layout component Drawing Nr. S
Drawn NY OSBL TDAE PROCESSING TYPICAL SCHEMATIC DRAWING
Z-4023938-30-103-1-30
A First Issued 07/08/2018 NY Checked QMR PLANT PROJECT 400V FEEDER/MOTOR 02-MCC-01 Customer Doc. Nr. Sheet 53
Rev N° Modification Date Name Approved IHD Order N° E2030-30927 Switchboard PT. SCHNEIDER INDONESIA 64 Sh.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
FROM FEEDER
02-MCC-01 -XB1 3 BR 4 BR 5
L1 L2 L3
A A
SAS
ES
PE
-XB1 10
PE
-XB1 7
B LCS
B
LOCAL
STOP START
1 3 5 54/C5 PB PB
-Q1 12 14 92 94
-XB1 8 -XB1 6 -XB1 9
11 91
2 4 6
C C
34 32 92 94
-Q1
SD
-F2 54/B3
-XL1 L1 L2 L3 31 91
55/E4
VW3A***
LI6
55/F3
U V W
55/C7
55/C8
-F1
D D
L1
L2
L3
LI1
A1
LI2
LI3
LI4
LI5
LI6
+24
PE1
R1B
R1C
R2C
R1A
R2A
PWR
AI1-
AO1
T1
T2
T3
AI1+
AI2
+10
GND
0V
COM
COM
PA/+
PB
P24
PO
PE2
PC/-
TSXPBSCAxxx
E E
COLLAR
-XL3 -XB1 13 14 15 GROUND
1
2
0V
DC
CHOKES -XBC 1 2 3 4 5 6
55/F3
All devices shown in this diagram are in open position, drawn out, with operating mechanism discharged and all power source off.
disclosed without its prior written consent. Only those drawings and diagrams remitted after order booking are binding for execution.
T
PE2
R
All technical information contained in this document is the exclusive property of PT. SCHNEIDER INDONESIA may neither be used nor
FROM PREVIOUS TO THE NEXT
PROFIBUS PANEL PROFIBUS PANEL
55/A1
55/A2
55/A2
55/A2
REMOTE POTENTIOMETER
F ADJUSTABLE F
08/06/2018
Date 07/08/2018 Project Name Title Power & Control Circuit Drawing Nr. S
Drawn NY OSBL TDAE PROCESSING TYPICAL SCHEMATIC DRAWING
Z-4023938-30-103-1-30
A First Issued 07/08/2018 NY Checked QMR PLANT PROJECT 400V FEEDER/MOTOR 02-MCC-01 Customer Doc. Nr. Sheet 54
Rev N° Modification Date Name Approved IHD Order N° E2030-30927 Switchboard PT. SCHNEIDER INDONESIA 64 Sh.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
54/F2
54/F2
54/F2
54/F2
R
1 2
PE2
-XB1
A A
TWISTED
1 3
-Q5
B 2P 2A B
2 4
22 24 12 14 R1A R2A
-F1 -F1
-XL2 54/D3 54/D3
-K1 -K1
C 21 11 C
55/D8 55/D8
1
+D
PE R1C R2C
-FAN2
1 2
PE
X1 X1 +D X1
PE
+D +D -FAN1 +D A1
-K1
-H4 -H5 -H6
Green Red 2 Amber
X2 X2 PE X2 A2
STOP RUN TRIP
D D
14 55/C5
11
12
24 55/C5
21
22
54/C4
-F2 34 31 32 A1 A2
SCREEN TWISTED
T1
T1
E -ZCT E
T2
T2
11 14 25 26 27
PE
R S T PE
-XB1 11
54/D6
LI6
All devices shown in this diagram are in open position, drawn out, with operating mechanism discharged and all power source off.
-XB1 12
disclosed without its prior written consent. Only those drawings and diagrams remitted after order booking are binding for execution.
54/E3
All technical information contained in this document is the exclusive property of PT. SCHNEIDER INDONESIA may neither be used nor
M 0V
3 ~ PTC
F F
08/06/2018
Date 07/08/2018 Project Name Title Power & Control Circuit Drawing Nr. S
Drawn NY OSBL TDAE PROCESSING TYPICAL SCHEMATIC DRAWING
Z-4023938-30-103-1-30
A First Issued 07/08/2018 NY Checked QMR PLANT PROJECT 400V FEEDER/MOTOR 02-MCC-01 Customer Doc. Nr. Sheet 55
Rev N° Modification Date Name Approved IHD Order N° E2030-30927 Switchboard PT. SCHNEIDER INDONESIA 64 Sh.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal type
TERMINAL PLAN Terminal ST2.5 [ 1 - 15 ]
Terminal
Terminal
A A
Terminal
Terminal
-XB1
Function Connection Target Signal Number Connection Target Reference
PH 1 =TYPE C&H (1) +M -Q5 2P 2A:1 55/A5
PH 2 =TYPE C&H (1) +M -Q5 2P 2A:3 55/A5
PH 3 54/A4
B B
PH 4 54/A5
PH 5 Connection is not unique. 54/A5
#1318372222 6 =TYPE C&H (1) +M -F1 :LI2 54/C5
#1318372171 7 =TYPE C&H (1) +C -XB1 :10 54/B4
#1318372201 8 =TYPE C&H (1) +M -F1 :LI1 54/C4
#1318372223 9 =TYPE C&H (1) +M -F1 :LI4 54/C5
#1318372171 10 =TYPE C&H (1) +C -XB1 :7 54/B4
LI6 11 =TYPE C&H (1) +M -F1 :LI6 55/F3
C 0V 12 =TYPE C&H (1) +M -F1 :0V 55/F3 C
#1318372240 13 =TYPE C&H (1) +M -F1 :+10 54/E4
#1318372244 14 =TYPE C&H (1) +M -F1 :AI1+ 54/E4
#1318372245 15 Connection is not unique. 54/E4
D D
E E
All devices shown in this diagram are in open position, drawn out, with operating mechanism discharged and all power source off.
disclosed without its prior written consent. Only those drawings and diagrams remitted after order booking are binding for execution.
All technical information contained in this document is the exclusive property of PT. SCHNEIDER INDONESIA may neither be used nor
F F
08/06/2018
Date 07/08/2018 Project Name Title Terminal List Drawing Nr. V
Drawn NY OSBL TDAE PROCESSING TYPICAL SCHEMATIC DRAWING
Z-4023938-30-103-1-30
A First Issued 07/08/2018 NY Checked QMR PLANT PROJECT 400V FEEDER/MOTOR 02-MCC-01 Customer Doc. Nr. Sheet 56
Rev N° Modification Date Name Approved IHD Order N° E2030-30927 Switchboard PT. SCHNEIDER INDONESIA 64 Sh.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal type
TERMINAL PLAN Terminal ST2.5 [ 1 - 6 ]
Terminal
Terminal
A A
Terminal
Terminal
-XBC
Function Connection Target Signal Number Connection Target Reference
N24 1 =TYPE C&H (1) +C -XBC :2 54/E7
N24 2 =TYPE C&H (1) +C -XBC :1 54/E7
P22 3 =TYPE C&H (1) +C -XBC :4 54/E7
B B
P22 4 =TYPE C&H (1) +C -XBC :3 54/E7
S 5 =TYPE C&H (1) +C -W1 SCREEN TWISTED:GND 54/E7
S 6 54/E7
C C
D D
E E
All devices shown in this diagram are in open position, drawn out, with operating mechanism discharged and all power source off.
disclosed without its prior written consent. Only those drawings and diagrams remitted after order booking are binding for execution.
All technical information contained in this document is the exclusive property of PT. SCHNEIDER INDONESIA may neither be used nor
F F
08/06/2018
Date 07/08/2018 Project Name Title Terminal List Drawing Nr. V
Drawn NY OSBL TDAE PROCESSING TYPICAL SCHEMATIC DRAWING
Z-4023938-30-103-1-30
A First Issued 07/08/2018 NY Checked QMR PLANT PROJECT 400V FEEDER/MOTOR 02-MCC-01 Customer Doc. Nr. Sheet 57
Rev N° Modification Date Name Approved IHD Order N° E2030-30927 Switchboard PT. SCHNEIDER INDONESIA 64 Sh.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
BILL OF MATERIALS
Device Designation Description Technical Data Reff/Part Number Manufacturer Panel Location Remarks
-ZCT Zero Current Transformer - *** Schneider Electric =TYPE C&H (1) +C -
A A
-H4 Indication Lamp Green Colour Dia 22mm, 230~240VAC/DC YW1P-1EQM3-G Idec =TYPE C&H (1) +D -
-H5 Indication Lamp Red Colour Dia 22mm, 230~240VAC/DC YW1P-1EQM3-R Idec =TYPE C&H (1) +D -
-H6 Indication Lamp Amber Colour Dia 22mm, 230~240VAC/DC YW1P-1EQM3-A Idec =TYPE C&H (1) +D -
-F1 Remote cables 2 RJ45 3M VW3A1104R30 Schneider Electric =TYPE C&H (1) +M -
-F1 Profibus Connector w/o Terminal - 490NAD91104 Schneider Electric =TYPE C&H (1) +M -
-F1 Remote Graphic terminal - VW3A1101 Schneider Electric =TYPE C&H (1) +M -
B -F1 Profibus communication card - VW3A3307 Schneider Electric =TYPE C&H (1) +M - B
-F1 Variable speed drive ATV71 **kW 380-480VAC 50/60Hz ATV71** Schneider Electric =TYPE C&H (1) +M -
-F2 Vigirex 0.03A-30A, 220-240VAC 50/60/400Hz, RH99M 56173 Schneider Electric =TYPE C&H (1) +M -
-FAN1 Fan 230VAC 165m3/h IP.54 c/w: NSYCVF165M230PF Sarel =TYPE C&H (1) +D -
-FAN2 Fan 230VAC 165m3/h IP.54 c/w: NSYCVF165M230PF Sarel =TYPE C&H (1) +D -
-K1 Module R/C 110-240VAC for RSB RZM041FU7 Schneider Electric =TYPE C&H (1) +M -
-K1 Plastic maintaining clamp for RSB RSZR215 Schneider Electric =TYPE C&H (1) +M -
C -K1 Auxiliary relay 2 change-over contacts 230VAC RSB2A080P7 + RSZE1S48M Schneider Electric =TYPE C&H (1) +M - C
-Q1 Moulded case circuit Breaker NSX Type 3P Fix c/w: *** Schneider Electric =TYPE C&H (1) +M -
-Q1 Trip contacts or Auxiliary contacts OF/SDE 29450 Schneider Electric =TYPE C&H (1) +M -
-Q1 Trip contacts or Auxiliary contacts OF/SDE 29450 Schneider Electric =TYPE C&H (1) +M -
-Q5 Miniature Circuit Breaker iC60H 2P, 2A, C Curve A9F84202 Schneider Electric =TYPE C&H (1) +M -
D -XL1 Passive filters In: **A ** Schneider Electric =TYPE C&H (1) +M - D
-XL2 Motor chokes **A *** Schneider Electric =TYPE C&H (1) +M -
-XL3 DC chokes **mH **A *** Schneider Electric =TYPE C&H (1) +M -
E E
All devices shown in this diagram are in open position, drawn out, with operating mechanism discharged and all power source off.
disclosed without its prior written consent. Only those drawings and diagrams remitted after order booking are binding for execution.
All technical information contained in this document is the exclusive property of PT. SCHNEIDER INDONESIA may neither be used nor
NOTES :
*** : DETAIL SEE SINGLE LINE DIAGRAM.
F F
08/06/2018
Date 07/08/2018 Project Name Title Bill Of Materials Drawing Nr. =TYPE C&H (1) V
Drawn NY OSBL TDAE PROCESSING TYPICAL SCHEMATIC DRAWING
Z-4023938-30-103-1-30 +D
A First Issued 07/08/2018 NY Checked QMR PLANT PROJECT 400V FEEDER/MOTOR 02-MCC-01 Customer Doc. Nr. Sheet 58
Rev N° Modification Date Name Approved IHD Order N° E2030-30927 Switchboard PT. SCHNEIDER INDONESIA 64 Sh.
1 2 3 4 5 6 7 8