0% found this document useful (0 votes)
46 views2 pages

Wireless LAN Adapter Installation Guide

Uploaded by

Dida
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views2 pages

Wireless LAN Adapter Installation Guide

Uploaded by

Dida
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

3P427537-1A Website

• For details on specifications, setting methods,


Names of Parts
M15B190A and FAQ, see our website.
A Wireless LAN connection adapter
WIRELESS LAN CONNECTION ADAPTER [BRP072A43]
URL SETUP button
INSTALLATION MANUAL http://daikincomfort.com/DuctlessWireless
POWER lamp (green)
lights when running. Use when connecting to a
[Resetting the connection adapter]
router (wireless LAN • If the [SETUP] button and the [MODE]
access point). button are held down together for 5
RUN lamp (orange) seconds, all lamps will begin blinking.
Safety Considerations lights when connecting to a If the [SETUP] button is pressed in
router (wireless LAN access this state, settings will revert to factory
• Do not use this product near medical equipment or persons using point).
Give this installation manual to the customer when installation is default values.
completed. cardiac pacemakers or defibrillators. This product may cause MODE button (Data including network settings and
life-threatening electromagnetic interference. AP lamp (yellow) Switches modes
• Read these Safety Considerations carefully to ensure correct power consumption history are
• Do not use this product near auto-control equipment such as lights when connected directly (RUN/AP) when held
installation. automatic doors or fire alarm equipment. to a smartphone.
erased.)
down.
• Be sure to complete trial operation of the air conditioner / heat pump, Doing so may result in accidents due to malfunctioning.
in advance, in accordance with the instructions in the installation • Immediately turn off the circuit breaker for the air conditioner / heat
manual for the air conditioner / heat pump. pump if there is an abnormal odor or sound, the unit is overheating,
• Meanings of WARNING and CAUTION symbols: or smoke is emanating from the unit.

WARNING : Indicates a potentially hazardous situation which, if


not avoided, could result in death or serious injury.
There is a risk of fire or malfunction.
Request an inspection by your dealer.
Installation Position Wiring Outline
• Turn off the circuit breaker for the air conditioner / heat pump if the
CAUTION : Indicates a potentially hazardous situation which, if product was dropped or the case is damaged.
not avoided, may result in minor or moderate injury. A Wireless LAN connection Inside the indoor unit
There is a risk of fire or electric shock.
It may also be used to alert against unsafe practices. adapter S21 S601
Request an inspection by your dealer.
WARNING • Do not install the wireless LAN connection adapter in the plenum S602
G HA PCB
• Only qualified personnel must carry out the installation work. of the building. Doing so may result in fire. G HA PCB
Installation must be done in accordance with this installation Electrical wiring box
manual. Improper installation may result in electric shock, fire, or CAUTION S403 H or J Harness
equipment damage. A Wireless LAN
• Do not install this product where gas leakage could be exposed connection adapter
• Use only specified accessories and parts for installation work. to open flames. Printed-circuit board
Failure to use specified parts may result in electric shock, fire, the If the gas leaks and builds up around the product, it may catch fire. of the indoor unit
product falling, or equipment damage. D Connection cord
• Touch a nearby metal object (doorknob, aluminum sash, etc.) to
• Before touching electrical parts, turn off the air conditioner / heat
discharge static electricity from your body before touching this set.
pump.
Static electricity from your body can damage this set.
• Electrical work must be performed in accordance with relevant
local and national regulations and with the instructions in this • Grip the connector when disconnecting the connection cord from
installation manual. Always use a dedicated circuit. the outlet.
Otherwise fire or electric shock can occur.
HA PCB Installation Procedure (1)
Failure to comply may result in electric shock or fire.
• Do not disassemble, modify, or repair. • Do not use where small children can get access.
Doing so may result in fire, electric shock, or injury. There is a risk of injury to small children.
• Do not handle this product with wet hands. Type A model Type B model Other models
Doing so may result in electric shock or fire.
• Do not use this product near a microwave oven. Not fitted with an S21 connector Not fitted with an S21 connector Fitted with an S21 connector
• Do not allow this product to get wet or use it when bathing or
similar activities using water. This can affect wireless LAN communications. (1 flap) (2 flaps)
Failure to comply may result in electric shock or fire.

Accessories 1 flap 2 flaps


etc.

A Wireless LAN B Serial number C Installation manual WARNING


connection adapter sticker *1 (multi-language) Be sure to turn OFF the power at the time of installation work.
1 1 1
Touching any electric parts with the power turned ON may cause electric shock.

D Connection E Fastening tape F Mounting screw


cord (1.6m) *2
1. Remove the front panel, service lid, and front grille in accordance with the installation
1 1 2 manual for the air conditioner.
2. Install the G HA PCB.
G Home automation H Harness (with ferrite core) *3 J Harness (without ferrite core) *3 Installation procedures for the G HA PCB differ by model type.
printed-circuit Refer to the relevant section.
1 1 1
board
(HA PCB) *3 For Type A model Proceed to “HA PCB Installation Procedure (2) Type A ”
*1 Attach to the sticker attachment area on this document and keep safe.
*2 Do not use extension or other cords.
*3 Not used with air conditioners fitted with an S21 connector. For Type B model Proceed to “HA PCB Installation Procedure (2) Type B ”

[About the SSID and KEY] For Other models Connect the D connection cord to the S21 connector in accordance with the
• The [SSID] and [KEY] shown on the B serial number sticker are
[Sticker attachment area] installation manual for the air conditioner.
necessary when connecting the air conditioner and a smartphone via Attach the B serial number sticker to the (It is not necessary to install the G HA PCB.) After making the connection, return
wireless LAN. sticker attachment area and keep safe. the front grille, service lid, and front panel to their original positions.

HA PCB Installation Procedure (2) Type A HA PCB Installation Procedure (2) Type B

3. Remove the electrical wiring box cover. 3. Remove the electrical wiring box cover.
• Disengage the hooks to remove the electrical wiring box cover. • Disengage the hooks to remove the electrical wiring box cover.

Hooks

Electrical wiring box cover Electrical wiring box cover Hooks

4. Remove the electrical wiring box (if necessary). 4. Remove the electrical wiring box (if necessary).
If there is workspace on the right-hand side of the indoor unit, the installation work can be conducted without removing the If there is workspace on the right-hand side of the indoor unit, the installation work can be conducted without removing the
electrical wiring box. Connect the G HA PCB without removing the electrical wiring box, if possible. electrical wiring box. Connect the G HA PCB without removing the electrical wiring box, if possible.
1) Disconnect the inter-unit wire. 1) Disconnect the inter-unit wire.
2) Disconnect the fan motor connector (S200) and swing motor connector (S6). 2) Disconnect the fan motor connector (S200) and swing motor connector (S6).
3) Disconnect the thermistor and ground wire from the heat exchanger (2 screws). 3) Disconnect the thermistor and ground wire from the heat exchanger (2 screws).
(Some models may not have ground wire.) (Some models may not have ground wire.)
4) Remove the mounting screw of the electrical wiring box (1 screw). 4) Remove the mounting screw of the electrical wiring box (1 screw).

Ground wire* S200 S6


Ground wire* S200
(Green/Yellow) S6 (Green/Yellow)

Ground wire* Ground wire*


(Green) (Green)
Inter-unit wire Inter-unit wire

Thermistor Thermistor
• Make sure that the • Make sure that the
mounting bracket of the mounting bracket of the
thermistor will not fall off. thermistor will not fall off.
Mounting screw of electrical
* The position of the ground wire may differ depending on the model. wiring box * The position of the ground wire may differ depending on the model. Mounting screw of electrical
wiring box
5. Install the HA PCB to the electrical wiring box. 5. Install the HA PCB to the electrical wiring box.
1) Attach the H harness (with ferrite core), by connecting it to the S601 and S602 connectors on the G HA PCB. (See Fig. 2) 1) Attach the J harness (without ferrite core), by connecting it to the S601 and S602 connectors on the G HA PCB. (See Fig. 2)
2) Insert the connector of the H harness (with ferrite core) into the S403 connector Fig. 1 2) Insert the connector of the J harness (without ferrite core) into the S403 connector Fig. 1
on the electrical wiring box. (See Fig. 2) on the electrical wiring box. (See Fig. 2)
3) Install the G HA PCB to the electrical wiring box. (See Fig. 2) 3) Install the G HA PCB to the electrical wiring box. (See Fig. 2)
4) Insert the D connection cord into the S21 connector (white) on the G HA PCB. (See Fig. 3) 4) Insert the D connection cord into the S21 connector (white) on the G HA PCB. (See Fig. 3)
• Insert the connector of the D connection cord without the cord anchor. (See Fig. 1) • Insert the connector of the D connection cord without the cord anchor. (See Fig. 1)
Cord anchor Cord anchor
5) Route the D connection cord as shown in the figure. (See Fig. 3) 5) Route the D connection cord as shown in the figure. (See Fig. 3)
D Connection cord D Connection cord

Fig. 2 S403 S601 Fig. 3 S21 connector (white) Fig. 2 J Harness (without ferrite core) Fig. 3
G HA PCB S21 connector (white)
G HA PCB To S403
S403
Electrical connector
wiring box
S602

S602 G HA PCB
To S403 H Harness S601
G HA PCB
connector (with ferrite core)
How to attach the G HA PCB
How to attach the G HA PCB

Spacer Back of the


Back of the G HA PCB
G HA PCB
D Connection D Connection
cord Spacer cord
Electrical wiring box
Electrical wiring box

6. Return the electrical wiring box cover and electrical wiring box (if it was removed) to their 6. Return the electrical wiring box cover and electrical wiring box (if it was removed) to their
original positions. original positions.
7. Return the front grille, service lid, and front panel to their original positions in accordance 7. Return the front grille, service lid, and front panel to their original positions in accordance
with the installation manual for the air conditioner. with the installation manual for the air conditioner.

01_EN_3P427537-1A.indd 1 2/22/2016 3:07:07 PM


Wireless LAN Connection Adapter Installation Procedure All types Preparation Before Configuring Connection Settings All types

The customer is responsible for providing the following.


The following procedures are also applicable to air • Smartphone or tablet PC
conditioners fitted with an S21 connector. (Supported OS: Android 4.0.3 or later; iOS 7.0 or later.)
• Internet line and communicating device
1. Remove the upper case of the A Wireless LAN connection adapter (Modem/router or a similar device)
• Wireless LAN access point
A wireless LAN connection adapter. Do not press the Upper (The corresponding channel for the wireless LAN connection adapter is 1-11.)
Press a slot-head screwdriver* into the dent between the screwdriver into case
• [DAIKIN Mobile Controller] (No Cost)
upper and lower cases of the A wireless LAN connection the hole for the
adapter to remove. (Be careful not to damage the case.) connection cord.
* Use a slot-head screwdriver with a wide head (0.2 inches Installation method of online controller
(5mm) or wider is recommended). Lower For Android Phones/Tablets For iPhones/iPads
Slot-head screwdriver case
(1) Open the [Google Play]. (1) Open the [App Store].
(2) Search for [Daikin Comfort Control]. (2) Search for [Daikin Comfort Control].
(3) Follow the directions on the screen to install. (3) Follow the directions on the screen to install.

2. Attach the D connection cord to the Connector Ensure that the connector on
the D connection cord is
A wireless LAN connection adapter. firmly inserted all the way.
1) Attach the connector of the D connection cord.
2) Fasten the D connection cord to the notch in the lower
Cord anchor Configuring Connection Settings (1) All types
case of the A wireless LAN connection adapter. Fasten the D connection
cord and ensure that Check whether the router to be used supports WPS.
external force is not
transmitted. If WPS is supported Proceed to Simple setup If WPS is not supported Proceed to Advanced setup

Simple setup
3. Install the lower case of the A wireless F Mounting screws When attaching the E fastening tape
LAN connection adapter to a wall, a • Attach it to the reverse side of the lower case. 1. Check that the [POWER] lamp is continuously lit and the [RUN] lamp
pillar, or similar location. is blinking.
Do not block the • If the [POWER] lamp is lit and the [RUN] lamp is not lit, hold down the [MODE] button on the
• Install the lower case so as to allow the upper case to be holes at the top
adapter for about 2 seconds to prompt the [RUN] lamp to begin blinking. (Blinking begins in
easily removed for maintenance purposes. and bottom.
about 30 seconds.) [MODE]
• Do not install outdoors or anywhere it is likely to get wet. button
• Do not install it near the sensor part of the indoor unit. E Fastening tape
Do not
fasten the • Depending on the type of the wall, there is a
screws possibility of damaging the wall, and the
2. Press the [WPS] button on the router (wireless LAN access point).
• Operation procedures for the [WPS] button vary by router (wireless LAN access point). [WPS] button
into the adapter falling.
indoor unit. Please install it after consulting with the client. For details, refer to the instruction manual for the router.

3. Hold down the [SETUP] button on the adapter for about 2 seconds.
Check that the • The [RUN] lamp will begin to blink more rapidly, and will change to a continuous light once a
4. Return the adapter case to its D connection cord is connection between the router (wireless LAN access point) and the adapter has been
original condition. securely fastened. established.
Close the adapter by hooking the top of the If a connection fails to establish, repeat procedures from step 1 of “Simple setup”.
upper case on the top clip of the lower case. Top clip of lower
If a connection still cannot be established, follow the procedures in “Advanced setup”.
case (In some cases, a connection cannot be established using the steps in “Simple setup” owing
to compatibility issues.)
4. Connect the smartphone (tablet PC) and the router (wireless LAN
Push until you hear a click.
access point).
• A connection can be established by opening the smartphone's Wi-Fi network list, selecting
the [SSID] for the router and entering its password.
5. Tap the installed app [Daikin Comfort Control] to start it.
5. Turn on the power supply, wait until the • If the connected air conditioner is listed in the units overview screen, setup is complete.
initialization is complete, and check that If it is not listed, tap (refresh) in the top right corner of the units overview screen.
the [POWER] lamp of the A wireless Note
LAN connection adapter lights up. • If an upgrade is available for your adapter, the notification icon “ ” will be displayed on the
units overview screen. Tap it to upgrade your firmware.
When turning on the power, always
attach the upper adapter case.

Configuring Connection Settings (2) All types Troubleshooting


The following table provides brief descriptions of how to handle problems or uncertainties when you install the product or make
Advanced setup • All steps are demonstrated using iOS. connection settings. Check our website for details.
URL • FAQ can be viewed via smartphone
1. Check that the [AP] lamp is lit (continuously). http://daikincomfort.com/DuctlessWireless/FAQ (tablet PC). To access, please scan
If the [AP] lamp is not lit, hold down the [MODE] button on the adapter the 2D barcode.
for about 2 seconds to prompt the [AP] lamp to light up (continuously).
(Lights in about 10 seconds.)
[MODE]
button When this happens Explanation and where to check
[RUN] lamp does not light up The [RUN] lamp blinks.
(continuously).  Perform Simple setup or Advanced setup again.
2. Connect the smartphone (tablet PC) directly with the adapter via wireless LAN.  Check that the [SSID] and password for the adapter are entered correctly.
• Open the smartphone's Wi-Fi network list, select the [SSID] (DaikinAP *****) shown on the B serial number sticker, or the  Move the router (wireless LAN access point) closer to the adapter.
A wireless LAN connection adapter, and then enter the [KEY].  The smartphone or router (wireless LAN access point) in use may not be supported.
Check our website for details.

3. Tap the installed app [Daikin Comfort Control] to start it.

4. Make the wireless connection settings.


After-sale Service
2
1
For inquiries concerning after-sale service, contact your dealer and advise them of the following details:
• Model name
* • Date of installation
• Conditions at the time of failure (as precisely as possible)
• Your address, name, and telephone number

(1) Tap [Configure (2) Select your home (3)


This telecommunication equipment is in compliance with FCC/IC requirements.
the wireless network from the Enter the password.
connection]. list. Tap [Connect].
FCC CAUTION
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
(4) Follow the on-screen instructions from here onward to complete setup.
operate the equipment.
(5) After implementing the setting above and the product and router (wireless LAN access point) are connected, the [RUN] lamp will light. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
If this blinks for 1 minute or longer, check the power to the router (wireless LAN access point), network name and the password and start
again from the first procedure. This device complies with Part 15 of FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
* To set the wireless connection manually, tap [Advanced network settings], turn off interference that may cause undesired operation of this device.
[Automatic IP address (DHCP)], fill in the required information for the Wi-Fi router, tap [ ]
and then tap [Connect] on the wireless connection screen. Follow the on-screen instructions
and then continue as in step (5). This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio
frequency (RF) Exposure Guidelines and RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment should be
installed and operated keeping the radiator at least 8 inches (20cm) or more away from person’s body.

Contains FCC ID:VPYLBYD


Contains IC: 772C-LBYD

5. Connect the smartphone (tablet PC) and the router (wireless LAN access point), and
then start [Daikin Comfort Control].
• Refer to step 4 and step 5 of “Simple setup”.

3P427537-1A

01_EN_3P427537-1A.indd 2 2/22/2016 3:07:09 PM