CONTRACT NUMBER: 4800001113
Construction of Interchanges 7 & 8 and Highway
55 Improvement Near Royal Places
MATERIAL SUBMITTAL
For
M/S.
AUG-2024
©NEOM [2024]. All rights reserved.
Document history
Revision code Description of changes Purpose of issue Date
01 First Issue For Approval 14, Aug 2024
Document approval
Prepared by Reviewed by Approved by
Name Inayat M Rauf M Yousaf
Job Title PQCS QA QC Manager Project Manager
Signature
Date -Aug-2024 -Aug-2024 -Aug-2024
DOCUMENT CODE : REVISION CODE: 01 PAGE 2 OF 8
Contents
MATERIAL SUBMITTAL FORM ............................................................................................................ 4
TECHNICAL COMPARISON/ COMPLIANCE SHEET .......................................................................... 6
MATERIAL SUBMITTAL DETAILS ....................................................................................................... 8
DOCUMENT CODE : REVISION CODE: 01 PAGE 3 OF 8
MATERIAL SUBMITTAL FORM
Saudi Pan Kingdom Material Submittal
Contractor
(SAPAC) Number
Contract and Work
4800001113 Date 24-Nov-2024
Order Number
Material Description Area of
Detectable Warning
(One item/ system per Application (Mark IC7 & 8 and Highway 55
Tape.
form) on Drawings)
11-140000-
Aconex Reference of Specification 11-140000-000010
0000100267-TYP-ELE- 0244-KAA-INF-SPC
Drawing with Revision Reference -000008
DRG-578003-02
Applicable Code/ Listed in NEOM
- ☒ YES ☐ NO
Standard Mandatory List
Locally Manufactured
Contractor’s
(Identify the Country of ☒ YES ☐ NO
Representative IR
Origin if imported, with
Name & Signature
justification)
Discipline:
☐ Architectural ☐ Civil/ Structure ☐ Mechanical ☒ Electrical ☐ Geotechnical
☐ Telecom, ICT &
☐ Interior Design ☐ Landscape ☐ MEP/ HVAC ☐ Sustainability
ELV
☐ Wet Services ☐ Transportation ☐ Fire Protection ☐ Traffic ☐ Others
Manufacturers/Suppliers:
Name & Address Global Source Trading Company
Local agent/ stockiest/
N/A
merchant (if any)
Delivery Duration (Long
Short Lead
Lead/ Short Lead)
Scheduled Delivery
After Approval Other Details N/A
Date on Site
Checklist for Attachments (as applicable):
☐ Design Mixes (Concrete / Asphalt /
☒ Index & Separators/ Fliers ☒ Drawings/ Specifications
JMF)
☒ Product Data ☒ Test Reports ☐ Mill Certificates
☒ Prequalification Approval
☒ Compliance Certificates ☒ Warranties (Mandatory)
Reference (Mandatory)
☐ LEED Submittals ☒ Source Quality Control Reports ☒ Certificates & Accreditations
☒ Previous Client Approvals ☐ Welding Certificates ☒ Safety Data Sheet
☐ Samples ☐ Mock-ups Record/ Data ☐ Delegated Design Submittals
DOCUMENT CODE : REVISION CODE: 01 PAGE 4 OF 8
☒ Maintenance Data
Lead Materials Engineer’s Review Comments
Engineering Director’s Review Comments
Incorporate Comments
Work May Proceed Revise and resubmit
Status & Proceed
code Issued for
Rejected Review not required
Construction
Project
Signature &
Manager’s
Date
name
NEOM
Signature &
Project
Date
Director
Received by Contractor
Signature &
Name
Date
DOCUMENT CODE : REVISION CODE: 01 PAGE 5 OF 8
Technical Comparison/ Compliance Sheet
Sr. Manufacturer/ Specification Specification Requirements Proposed Material/ Product Drawing Proposed Material/ Compliant Remarks
No. Supplier/ Section/ Sub- Properties/ Specification Reference Product/ Equipment with (Yes/ No) (Justify any
Applicator/ Installer section/ Clause (Approved IFC Model Number and Serial Deviations from
reference with Indicated Number Project
Location) Specification)
Global Source Section 2.4 Warning Tape: Acid -and Global DWT Typ B Warning 11-140000- GDWTEL15-A
01 Trading Company Accessories alkali- resistant, Tapes are 6’’ (152 mm) wide, 0000100267-TYP- GDWTTL15-A
Part A. polyethylene film warning 100 micron thick, plastic coated ELE-DRG-578003- GDWTLV15-A YES N/A
tape manufactured for with continuous aluminum core.
02 GDWTHV15-A
11-140000- marking and identifying The tapes have continuous print
0000100244 underground utilities, (150 in both Arabic and English,
-KAA-INF-S mm) wide and (0.1 mm) indicating the line below
PC-000008
thick, continuously inscribed ‘’ACTION, BURIED Line below’’.
with a description of the The tapes are colored and
utility; colored as follows: printed as per APWA Standard.
Blue: Water systems.
Green: Sewer systems Blue: Water line
Green: Sewer line
11-140000- Detectable Warning Tape: Yes N/A
0000100244 Acid -and alkali- resistant,
-KAA-INF-S
polyethylene film warning
PC-000008
tape manufactured
for marking and identifying
Part B.
underground utilities, a
minimum of (150 mm) wide
and (0.1 mm) thick,
continuously inscribed with a
description of the utility,
with metallic core encased in
a protective
jacket for corrosion
protection, detectable by
DOCUMENT CODE : REVISION CODE: 01 PAGE 6 OF 8
metal detector when tape is
buried up to (750 mm)
deep; colored as follows:
Blue: Water systems.
Green: Sewer systems.
Red: Electric.
Yellow: Gas, Oil, Steam, and YES
dangerous materials.
Yellow: Telephone and other
communications.
Blue: Water System.
Green: Sewer System
WE CERTIFY THAT ALL THE REQUIREMENTS OF THIS SPECIFICATION FOR THE PROPOSED MATERIALS/PRODUCT/EQUIPMENT HAS BEEN COMPARED, AND THE DEVIATIONS FROM THE SPECIFICATION (IF ANY) HAVE BEEN SPECIFICALLY IDENTIFIED AND ARE
DEEMED ACCEPTABLE. PERMISSION TO PROCEED SHALL NOT CONSTITUTE ACCEPTANCE OR APPROVAL OF MATERIALS SELECTED BY CONTRACTOR AND SHALL NOT RELIEVE CONTRACTOR FROM FULL COMPLIANCE WITH CONTRACT TECHNICAL
SPECIFICATIONS, AND APPLICABLE LOCAL AUTHORITIES' SPECIFICATIONS.
Manufacturer/ Supplier Representative
Manufacturer/ Supplier Name Contractor Name Contractor Representative Signature & Stamps
Signature & Stamps
Global Source Trading Company Furqaan Haneef SAPAC
DOCUMENT CODE : 07-001100-4800000936-KTC-STR-MAT-000001 REVISION CODE: 01 PAGE 7 OF 8
Electronic documents once printed, are uncontrolled and may become outdated. Refer to EDMS for current revision.
MATERIAL SUBMITTAL DETAILS
DOCUMENT CODE : REVISION CODE: 01 PAGE 8 OF 8