0% found this document useful (0 votes)
44 views11 pages

Extrait de Endoscope Overview 2016 - 2017

The document provides an overview of various medical video endoscopes and fiber endoscopes, detailing their specifications such as insertion tube diameter, bending capabilities, working length, and field of view. It includes a range of models for gastroscopes, duodenoscopes, colonoscopes, bronchoscopes, and more, highlighting features like NBI and HDTV compatibility. The information is intended for medical professionals to explore the capabilities and options available in endoscopic technology.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views11 pages

Extrait de Endoscope Overview 2016 - 2017

The document provides an overview of various medical video endoscopes and fiber endoscopes, detailing their specifications such as insertion tube diameter, bending capabilities, working length, and field of view. It includes a range of models for gastroscopes, duodenoscopes, colonoscopes, bronchoscopes, and more, highlighting features like NBI and HDTV compatibility. The information is intended for medical professionals to explore the capabilities and options available in endoscopic technology.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ENDOSCOPE OVERVIEW

2016 / 2017

1
9338
IMAGINE...
Your Thumb Could
Maximize ADR.

Explore the evidence at: www.olympus.eu/proven

2 3
14846
MEDICAL VIDEO ENDOSCOPES
Insertion Distal Channel Working Depth
Bending Bending Field
Tube OD End OD ID Length of Field NBI Comments
(Up/Down) (Left/Right) of View
(mm) (mm) (mm) (mm) (mm)
Video Gastroscopes
2 – 6 (near)
GIF-HQ190* 9.9 9.9 2.8 210°/ 90° 100°/100° 1030 140°  DF, OT, WJ, HDTV
5 – 100

GIF-H190* 9.2 9.2 2.8 210°/ 90° 100°/100° 1030 140° 2 – 100  CF, OT, WJ, HDTV

GIF-1TH190* 10.9 10.0 3.7 210°/90° 100°/100° 1030 140° 2 – 100  CF, OT, WJ, HDTV

GIF-XP190N* 5.8 5.4 2.2 210°/ 90° 100°/100° 1100 140° 3 – 100  OT, HF compatible

GIF-H185* 9.2 9.2 2.8 210°/ 90° 100°/100° 1030 140° 2 – 100  CF, OT, HDTV

GIF-N180 4.9 4.9 2.0 210°/ 120° – 1100 120° 3 – 100  SlimSIGHT

GIF-2TH180** 12.6 12.2 2.8/3.7 210°/ 90° 100°/100° 1030 140° 2 – 100  HDTV

GIF-XTQ160 12.9 12.9 6.0 200°/ 90° 100°/100° 1030 140° 3 – 100 — –

60° (tele) 2 – 3.5 (tele)


GIF-FQ260Z• 10.5 11.0 2.8 210°/ 90° 100°/100° 1030  AFI
140° 7 – 100
Video Duodenoscopes

TJF-Q180V 11.3 13.7 4.2 120°/ 90° 90°/ 110° 1240 100°/ 5° (retro) 5 – 60  V-System

TJF-160VR 11.3 13.5 4.2 120°/ 90° 90°/ 110° 1240 100°/ 5° (retro) 5 – 60 — V-System

TJF-145 12.5 13.2 4.2 120°/ 90° 90°/ 110° 1240 100°/ 5° (retro) 5 – 60 — –

Subject to change without notice. Liability for errors and omissions excepted.
JF-140R 11.0 12.6 3.2 120°/ 90° 90°/ 110° 1240 100°/15° (retro) 5 – 60 — –

Video Choledochoscope

CHF-V** 5.2 4.9 2.0 160°/130° – 380 120° 3 – 50  –

Discover more at: www.nbi-portal.eu


*with CV-190 only **with CV-180 or higher ***with CV-160 or higher ****with EC-10 ENDOCAPSULE system only OT = One-touch Connector DF = Dual Focus CF = Close Focus WJ = WaterJet
• with CV-290/-260SL only ••with CV-290/-260SL/-240/-200 only RIT = Responsive Insertion Technology SG = ScopeGuide VS = Variable Stiffness
4 5
MEDICAL VIDEO ENDOSCOPES
Insertion Distal Channel Working Depth
Bending Bending Field
Tube OD End OD ID Length of Field NBI Comments
(Up/Down) (Left/Right) of View
(mm) (mm) (mm) (mm) (mm)
Video Colonoscopes

160° (near) 2 – 6 (near) DF, OT, RIT, SG,


CF-HQ190I/L* 12.8 13.2 3.7 180°/180° 160°/160° 1330/1680 
170° 5 – 100 WJ, HDTV
CF, OT, RIT,
CF-H190I/L* 12.8 13.2 3.7 180°/180° 160°/160° 1330/1680 170° 2 – 100 
WJ, HDTV
CF, OT, RIT, SG,
PCF-H190DI/L* 11.8 11.7 3.2 180°/180° 160°/160° 1330/1680 170° 2 – 100 
WJ, HDTV
CF, OT, RIT,
PCF-H190I/L* 11.5 11.7 3.2 180°/180° 160°/160° 1330/1680 170° 2 – 100 
WJ, HDTV
CF, OT, RIT
PCF-PH190I/L* 9.5 9.7 3.2 180°/180° 160°/160° 1330/1680 140° 2 – 100 
(HFT, PB), HDTV
CF, OT, VS, WJ,
CF-H185I/L* 12.8 12.8 3.7 180°/180° 160°/160° 1330/1680 140° 2 – 100 
HDTV

CF-2T160I/L 13.7 13.8 3.7/3.2 180°/180° 160°/160° 1330/1680 140° 3 – 100 – –

80° (tele) 2 – 3 (tele)


CF-FH260AZI/L• 13.2 14.8 3.2 180°/180° 160°/160° 1330/1680  AFI
140° 7 – 10

Video Enteroscope

SIF-Q180 9.2 9.2 2.8 180°/180° 160°/160° 2000 140° 3 – 100  –

Capsule Endoscope

Subject to change without notice. Liability for errors and omissions excepted.
EC-S10**** 11.0 11.0 – – – 26 160° 0 – 20 – –

Discover more at: www.nbi-portal.eu


*with CV-190 only **with CV-180 or higher ***with CV-160 or higher ****with EC-10 ENDOCAPSULE system only OT = One-touch Connector DF = Dual Focus CF = Close Focus WJ = WaterJet
• with CV-290/-260SL only ••with CV-290/-260SL/-240/-200 only RIT = Responsive Insertion Technology SG = ScopeGuide VS = Variable Stiffness
6 7
MEDICAL VIDEO ENDOSCOPES

Insertion Distal Channel Rotation Working Depth


Bending Field
Tube OD End OD ID Function Length of Field NBI Comments
(Up/Down) of View
(mm) (mm) (mm) (Left/Right) (mm) (mm)
Video Bronchoscopes

BF-1TH190* 6.0 6.2 2.8 180°/130° 120°/120° 600 120° 3 – 100  HDTV, OT

BF-H190* 5.1 5.5 2.0 210°/130° 120°/120° 600 120° 3 – 100  HDTV, OT

BF-Q190* 4.9 4.8 2.0 210°/130° 120°/120° 600 120° 3 – 100  OT

BF-P190* 4.1 4.2 2.0 210°/130° 120°/120° 600 110° 2 – 50  OT


BF-XP190* 2.8 3.1 1.2 210°/130° 120°/120° 600 110° 2 – 50  OT

BF-1TQ180 6.2 6.3 2.8 180°/130° – 600 120° 3 – 100  —

BF-1T180 6.0 6.0 3.0 180°/130° – 600 120° 3 – 100  —

BF-Q180-AC 5.3 5.5 2.0 180°/130° – 600 120° 3 – 100  Autoclavable

BF-Q180 5.1 5.5 2.0 180°/130° – 600 120° 3 – 100  —

BF-P180 4.9 4.9 2.0 180°/130° – 600 120° 3 – 100  —

BF-XT160*** 6.3 6.2 3.2 180°/130° – 600 120° 3 – 100 — —

BF-3C160*** 3.8 3.8 1.2 180°/130° – 600 120° 3 – 100 — —

BF-1T260•• 6.0 5.9 2.8 180°/130° – 600 120° 3 – 100 — –

Subject to change without notice. Liability for errors and omissions excepted.
BF-F260• 5.4 5.5 2.0 180°/130° – 600 120° 3 – 100 — AFI

BF-260•• 4.9 4.9 2.0 180°/130° – 600 120° 3 – 100 — –

Mobile Airwayscopes

MAF-TM 5.2 5.1 2.6 180°/130° – 600 90° 3 – 50 — Fibervideoscope

MAF-GM 4.1 3.9 1.5 120°/120° – 600 90° 4 – 50 — Fibervideoscope

Video Pleuroscope (Medical Thoracoscopy)

LTF-160 7.0 7.0 2.8 160°/130° – 270 120° 3 – 100 — Autoclavable

*with CV-190 only **with CV-180 or higher ***with CV-160 or higher ****with EC-10 ENDOCAPSULE system only OT = One-touch Connector DF = Dual Focus CF = Close Focus WJ = WaterJet
•with CV-290/-260SL only ••with CV-290/-260SL/-240/-200 only RIT = Responsive Insertion Technology SG = ScopeGuide VS = Variable Stiffness

tapered part of distal end 2.9 mm
8 9
MEDICAL FIBER ENDOSCOPES
Insertion Distal Channel Working Depth
Bending Bending Field
Tube OD End OD ID Length of Field Comments
(Up/Down) (Left/Right) of View
(mm) (mm) (mm) (mm) (mm)
Gastrointestinal Fiberscopes

CF-E3I/L 12.9 13.8 3.2 180°/180° 160°/160° 1330/1680 140° 5 – 100 –

GIF-E3 9.8 9.8 2.8 210°/ 90° 100°/100° 1025 120° 3 – 100 –

CHF-BP30 3.4 3.1 1.2 160° 130° 1870 90° 1 – 50 Baby scope

Fiber Bronchoscopes

BF-1T60 6.0 5.9 3.0 180°/130° – 600 120° 3 – 50 –

BF-P60 5.0 4.9 2.2 180°/130° – 600 120° 3 – 50 –

BF-MP60 4.4 4.0 2.0 180°/130° – 600 120° 3 – 50 –

BF-XP60 2.8 2.8 1.2 180°/130° – 600 90° 2 – 50 –

BF-3C40 3.6 3.3 1.2 180°/130° – 550 120° 3 – 50 –

BF-N20 2.2 1.8 – 160°/90° – 550 75° 2 – 50 –

BF-TE2 6.0 5.9 2.8 180°/130° – 600 120° 3 – 50 –

BF-PE2 5.0 4.9 2.2 180°/130° – 600 120° 3 – 50 –

10 11 Subject to change without notice. Liability for errors and omissions excepted.
ENDOSCOPY INTEGRATION

The ENDOALPHA system is the total integration solution for Recovery Area
endoscopy, consisting of modular components that are combined Patient comfort and safety in perfection
to meet the individual needs of the hospital. Utmost support – a central overview of the status of the
rooms, support smooth processes and
throughout the workflow from patient reception to the examination,
a stressless atmosphere.
via the reprocessing and recovery areas, ending in the doctor’s
office and training room facilities.
· Access to status of endoscopy room
· Patient-care documentation for
recovery nurse

9335
Examination Room
A high level of ergonomics, efficiency,
and communication in a modern and
friendly ambience.
Doctor’s Office
· Optimized workspace and patient In the office but with an optimal audio/
comfort video connection to the examination
· Integrated HD documentation system rooms. Access from the PC to all data
· Saving space, examination, and and images and reporting system.
9337

cleaning time
· Access to centralized patient/
procedure information
9334
· Audio/video connection to
examination rooms
· Tools for activity and cost analysis
Reprocessing Area
Hygiene supports and secures the
endoscope’s workflow with full
traceability and documentation of all Training / Meeting Room
relevant reprocessing steps. The media center for training, courses,
and seminars with advanced video
· ETD Double and ETD4 washer management, including live video and
disinfectors bidirectional communication from
· EDC Plus Drying and storage cabinets examination rooms.
3284

· ETS Endoscope transport solutions


· Access/display of departmental
9337

activity information
· IP audio/video routing and multi-
display functionality

12 13
ENDOSCOPIC ULTRASOUND

Insertion Channel Bending Working Ultrasound Endoscopic Field Depth


Frequency Scanning
Tube OD ID (Up/Down Length Field of of View of Field
(MHz) Mode
(mm) (mm) Left/Right) (mm) View (Forward/Oblique) (mm)
Ultrasonic Videoscopes for EUS

130°/ 90° 5/6/7.5/10/12* Electronic 360°


GF-UE160-AL5 11.8 2.2 1250 360° 100°/ 55° 3 – 100
90°/90° radial array

130°/90° Electronic curved


GF-UCT180 12.6 3.7 1250 180° 100°/55° 3 – 100 5/6/7.5/10/12*
90°/90° linear array

130°/ 90° Electronic curved


GF-UCT140-AL5 12.6 3.7 1250 180° 100°/ 55° 3 – 100 5/6/7.5/10/12*
90°/90° linear array

130°/ 90° Electronic curved


GF-UC140P-AL5 11.8 2.8 1250 180° 100°/ 55° 3 – 100 5/6/7.5/10/12*
90°/90° linear array

180°/90° Forward Viewing,


TGF-UC180J 12.6 3.7 1245 90° 120°/0° 3 – 100 5/6/7.5/10/12* electronic curved
90°/90° linear array
Ultrasonic Endoscope for EBUS

120°/ 90° Electronic curved


BF-UC180F** 6.3 2.2 600 60° 80°/35° 2 – 50 5/6/7.5/10/12*
– linear array

Ultrasonic Rectal Probes

rigid Mechanical
RU-75M-R1 12.0 – 150 360° – – 7.5
rigid radial

Subject to change without notice. Liability for errors and omissions excepted.
rigid Mechanical
RU-12M-R1 12.0 – 150 360° – – 12
rigid radial

*with EU-ME2. Please contact your Olympus representative for compatibility with other systems.
**fibervideoscope for best ratio between outer diameter and working channel size.
***equipped with 0.035" guidewire port at the distal end.

14 15
ENDOSCOPIC ULTRASOUND

Frequency Working Insertion Tube Comp. Biopsy Comp. Biopsy Scanning


Model
(MHz) Length (mm) OD (mm) Channel (mm) Channel (mm) Mode

Ultrasonic Miniature Probes

MH-246R
UM-2R/3R 12/20 2050 2.5 2.8 3.7 Mechanical radial
Balloon Sheath

K-201 / K-202
UM-S20-17S 20 2150 max. 1.8 2.0 2.0 Mechanical radial
GuideSheathKit

K-203 / K-204
UM-S20-20R 20 2050 max. 2.0 2.2• 2.6 Mechanical radial
GuideSheathKit

MAJ-643R
UM-BS20-26R 20 2050 Use only with balloon sheath 2.8 Mechanical radial
Balloon Sheath

UM-G20-29R*** 20 2050 max. 2.9 3.2 Not used with balloon sheath Mechanical radial

UM-DG20-31R*** 20 2050 max. 3.1 3.7 Not used with balloon sheath
Mechanical
helical for
Dual Plane
UM-DP12-25R 12 2050 2.5 2.8
Reconstruction
Not used with balloon sheath (DPR)

Subject to change without notice. Liability for errors and omissions excepted.
UM-DP20-25R 20 2050 2.5 2.8

*with EU-ME2. Please contact your Olympus representative for compatibility with other systems.
**fibervideoscope for best ratio between outer diameter and working channel size.
***equipped with 0.035” guidewire port at the distal end.
•2.0 mm in bronchoscopes

16 17
SURGICAL VIDEO ENDOSCOPES
Insertion Distal End Channel Working Depth of
Bending Bending Direction Field
Tube OD OD ID Length Field NBI HDTV/SDTV
(Up/Down) (Left/Right) of View of View
(mm) (mm) (mm) (mm) (mm)
ENDOEYE Laparoscopes

ENDOEYE FLEX 3D, 10 mm 10.0 10.0 — 100°/ 100° 100°/ 100° 370 0° 80° 18 – 100  HDTV

ENDOEYE HD II, 10 mm 0° 10.0 10.0 — — — 325 0° 90° 21 – 200  HDTV

ENDOEYE HD II, 10 mm 30° 10.0 10.0 — — — 330 30° 90° 21 – 200  HDTV

ENDOEYE FLEX, 10 mm 10.0 10.0 — 100°/ 100° 100°/100° 370 0° 100° 18 – 200  HDTV

ENDOEYE HD II, 5 mm 0° 5.4 5.4 — — — 325 0° 90° 21 – 200  HDTV

ENDOEYE HD II, 5 mm 30° 5.4 5.4 — — — 330 30° 90° 21 – 200  HDTV

ENDOEYE FLEX, 5 mm 5.4 5.3 — 100°/ 100° 100°/100° 370 0° 85° 18 – 100  HDTV

Cystoscopes

CYF-VH/-VHA/-VHR 5.5 2.7 2.2 220°/130° — 380 0° 120° 3 – 50  HDTV

CYF-V2/VA2 5.4 4.8 2.2 210°/ 120° — 380 0° 120° 3 – 50  SDTV

Ureteroscopes

URF-V2 2.8 2.83 1.2 275°/275° — 670 0° 80° 2 – 50  SDTV

URF-V 3.3 2.8 1.2 180°/275° — 670 0° 90° 2 – 50  SDTV

Rhinolaryngoscopes

ENF-VH 3.6 3.9 — 130°/130° — 300 0° 110° 3 – 50  HDTV

Subject to change without notice. Liability for errors and omissions excepted.
ENF-V3 2.9 2.6 — 130°/130° — 300 0° 90° 3 – 50  SDTV

ENF-V2 3.4 3.2 — 130°/130° — 300 0° 90° 5 – 50  SDTV

ENF-VT2 4.9 4.8 2.0 130°/130° — 365 0° 90° 2 – 40  SDTV

ENF-VQ 3.6 3.9 — 130°/130° — 300 0° 90° 5 – 50  SDTV

Tracheal Intubation Scope

LF-V 4.1 3.8 1.2 120°/120° — 600 0° 120° 3 – 50 — SDTV

Mobile Airwayscopes

MAF-GM 4.1 3.9 1.5 120°/120° — 600 0° 90° 4 – 50 — SDTV

MAF-TM 5.2 5.1 2.6 180°/130° — 600 0° 90° 3 – 50 — SDTV

Discover more at: www.nbi-portal.eu


All rigid endoscopes are compatible with EXERA III / VISERA ELITE via 3 CCD HD camera heads (HDTV),
1 CCD HD camera heads (HDTV) and via VISERA camera heads (SDTV).

18 19
SURGICAL FIBER ENDOSCOPES

Insertion Tube Distal End Channel Bending Bending Working Field Depth of
OD (mm) OD (mm) ID (mm) (Up/Down) (Left/Right) Length (mm) of View Field (mm)
Ureteroscope

URF-P6 2.65 1.7 1.2 275°/275° – 700 90° 2 – 50


Cystoscope

CYF-5/5A 5.5 4.6 2.4 210°/120° – 380 120° 3 – 50


Rhinolaryngoscopes

ENF-GP 3.6 3.4 – 130°/130° – 300 85° 5 – 50

ENF-P4 3.6 3.4 – 130°/130° – 300 85° 2.5 – 50

ENF-XP 2.2 1.8 – 130°/130° – 300 75° 2.5 – 50

ENF-T3 5.0 4.8 2.2 130°/130° – 365 85° 5 – 50


Tracheal Intubation Scopes

LF-P 2.2 1.8 – 120°/120° – 600 75° 3 – 50

LF-GP 4.1 3.8 1.5 120°/120° – 600 90° 4 – 50

LF-DP 3.1 3.1 1.2 120°/120° – 600 90° 3 – 50

LF-TP 5.2 5.1 2.6 180°/130° – 600 90° 3 – 50


Choledochoscopes

CHF-CB30L 2.8 2.7 1.2 120°/120° – 700 75° 2.5 – 50

Subject to change without notice. Liability for errors and omissions excepted.
CHF-CB30S 2.8 2.7 1.2 120°/120° – 450 75° 2.5 – 50

CHF-P60 5.2 4.9 2.2 160°/130° – 380 120° 4 – 50


Hysteroscope

HYF-XP 3.1 3.0 1.2 100°/100° – 230 100° 2 – 50

All fiber endoscopes are compatible with EXERA III / VISERA ELITE via 3 CCD HD camera heads (HDTV),
1 CCD HD camera heads (HDTV) and via VISERA camera heads (SDTV).

20 21