Tan Delta Test - Purpose, Principle, Circuit, Modes and Testing

The Tan Delta Test is a method used to assess the quality of insulating oil in transformers by measuring the dissipation factor and capacitance values at different voltage levels. This test helps identify insulation degradation and ensures the reliable operation of transformers. The document details the principles, testing process, and various modes of the Tan Delta Test, emphasizing its importance in transformer maintenance.

Uploaded by

Ranjit Raval
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
239 views7 pages

Tan Delta Test - Purpose, Principle, Circuit, Modes and Testing

The Tan Delta Test is a method used to assess the quality of insulating oil in transformers by measuring the dissipation factor and capacitance values at different voltage levels. This test helps identify insulation degradation and ensures the reliable operation of transformers. The document details the principles, testing process, and various modes of the Tan Delta Test, emphasizing its importance in transformer maintenance.

Uploaded by

Ranjit Raval
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

HOME ELECTRICAL › ELECTRONICS › COMMUNICATION › ROBOTICS PROJECTS ›

Projects › Project Ideas IC › Embedded Sensors Components Tools › Infographic

What is Tan Delta Test : Its Principle and Mo


Well, we all know that there are extensive applications of transformers across many domains. So,
more crucial to dig deep into the concept of transformer maintenance which involves oil tests, equi
testing, and many others. More concentration is necessary to perform dissolved gas testing where
analyses the entire electrical condition of the transformer. As transformer oil is utilized in circuit bre
cables, and switches, one has to test the conditioning of the oil too. This is because oil augments t
dielectric properties and hence Tan Delta Test is Used to know the condition of oil in the transforme
article provides a clear and detailed description of what is Tan Delta Test, its principle, different me
and various modes

What is the Tan Delta Test?


Tan Delta which is also termed as Dielectric Dissipation or Loss Angle or Power Factor testing met
which is performed for testing of insulating oil to know the quality level of the oil. This kind of testin
methodology is carried out at two temperature levels. The results that are obtained from the two te
compared and then consideration is taken in the quality level of the coil. If the test results are good
is continued in service and when the test results are not as expected, then either replacement or c
oil takes place.

Purpose
The main purpose of the tan delta test is to make sure of maintaining a secure and reliable funct
the transformer. With the calculation of dissipation factor and capacitance values, it provides the re
insulation behavior of bushings and in windings too.

Start a Design
Step by Step
Free online Transformer/
Inductor/Magnetic Design and
Calculator

poweresim.com

Variation in the capacitance value, for instance, it indicates partial kind of breakdowns in bushings
automated movement of windings. Insulation deprivation, aging of the equipment, enhancement in
energy levels is transformed into heat. The amount of losses in these is calculated as the dissipatio
factor.

With the tan delta testing method, one can easily know the dissipation factor and the capacitance v
the required level of frequencies. So, any kind of aging factor can be identified earlier and the
corresponding action can be implemented.

Principle of Tan Delta Test

When a pure insulator has a connection between the earth and the line, then it performs like a cap
an ideal kind of insulator, as the insulating substance functions as a dielectric, which is totally pure
the passage of current through the material holds only capacitive material. There will be no resistiv
element for the electric current that is flowing from the line to the earth via insulator as in the insula
component, there will be no presence of impurities. The tan delta test circuit diagram is shown a
follows:
Tan Delta Test Circuit

In a pure capacitive material, the capacitive current precedes the voltage level by 900. As a genera
insulating material is totally pure, and even because of the aging properties of the components, the
contaminations such as moisture and dirt might get added. These contaminations create a conduc
for the current. As a result, leakage current that flows from line to earth via the insulator holds resis
elements.

Therefore, it is pointless to claim that, for a good quality of insulator, this resistive element of leaka
current is correspondingly minimal. In the other aspect, the behavior of an insulator might be know
proportion of the resistive element to that of the capacitive element. For good quality of insulator, th
proportion is correspondingly less and this is termed as tanδ or tan delta. In a few cases, this is als
expressed as a dissipation factor. With the below-depicted vector diagram, it can be known.

Tan Delta Test Vector Diagram

Where the x-axis represents the level of system voltage which is the resistive element of leakage c
IR. As this capacitive element of leakage current IC precedes by 900, it is taken across the y-axis.

And now, the whole leakage current is given by IL(IC + IR)

And from the diagram, tanδ is (IR /IC)

tanδ = (IR /IC)


Tan Delta Testing Process

The below process explains the method of tan delta testing in a step-by-step manner.

The requirements necessary for this test such as cable, potential transformer, bushings, current
transformer, and winding on which this testing is conducted has to be initially separated from the
system.
The minimal frequency level of test voltage is applied along with the equipment where the insula
be analyzed.
At first, normal voltage levels are applied. When the tan delta values are as expected at this volt
level, then the applied voltage level is increased by 2 times as of applied voltage.
The values of the tan delta are recorded by the tan delta controller.
To the tan delta calculating component, a loss angle analyzer is connected which compares tan
values at higher and general voltage levels and delivers accurate results.

It has to be noted that the testing procedure to be carried out at very minimal frequency levels.

It is more recommended to conduct testing at minimal frequency levels, because when the applied
level is more, then the capacitive reactance of the insulator device reaches very minimal, therefore
capacitive element of the current reaches more. As the resistive element is practically constant; it i
on the applied voltage level and the insulator’s conductivity value.

Whereas at increased frequency level the capacitive current, is more, and then the amplitude of th
amount of both the capacitive and resistive elements of the current reaches very high. So, the nec
level of power for the tan delta test would become more that seems to be not acceptable. Because
the power constraint for dissipation factor analysis, very minimal frequency test voltage is required

Predicting the Test Results

These exist mainly two approaches to analyze the situation of the insulation method at the time of
testing. The first is, evaluating the past test results to know the worsening of insulation conditions b
of the aging effect. Whereas the second scenario is to verify the insulation behavior directly from ta
value. Here, there is no necessity of assessing past results with that tanδ test values.

When the insulation results are accurate, then the loss factor values are nearly similar for the entir
voltage values. But, in the case when the insulation results are not accurate, then the tanδ values
increased for a higher level of voltages. The increasing tanδ corresponds that, high resistive curren
element, happens in insulation. These outcomes might be matched with the outcomes of past teste
insulators, to go with the appropriate decision either the equipment has to be substituted or not.

This is the way that how to test the result tan delta testing can be done.

What are the Different Modes of the Tan Delta Test?


When it comes to tan delta test, there are essentially three modes of power factor testing. Those a

GST Guard – This calculates the amount of current leakage to the ground. This method elimina
current leakage through red or blue leads. Whereas in UST, the ground is termed to be guard be
grounded edges are not calculated. When the UST method is applied on the device, then the cu
measurement is only through blue or red leads. The current flow through ground lead gets autom
bypassed to the AC source and thus excluded from the calculation.
UST Mode – This is employed for the calculation of insulation in between ungrounded leads of t
equipment. Here the individual portion of isolation has to be separated and analyze it having no
insulation connected to it.
GST Mode – In this final mode of operation, both the leakage pathways are calculated by the te
apparatus. The current, capacitance values, UST, and GST guards, loss in watts need to be equ
GST test parameters. This provides the entire behavior of the test.

When the summing value of GST Guard and UST is not equal to the GST parameters, then it can
known that there is some crashing in the test set, or might the test terminal are not correctly design

On the whole, this is a detailed explanation of the Tan Delta Test. Here, in this article, we are comp
aware of what is a tan delta test, its principle, purpose of it, methods, and testing technique. Also k
about what are LV to earth test, HV to earth test, and LV-HV tan delta testing methodologies?
SHARE THIS POST:

Facebook Twitter Google+ LinkedIn Pinterest

‹ PREVIOUS

Electronics Interview Questions & Ans


MTech Projects for Electronics and Electrical
Engineering

RELATED CONTENT
Loop Antenna : Design, Corner Reflector : Working, Space Division Multiplexing : Microstrip Antenna :
Working, Types, Radiation Types, Calculation, radiation Diagram, Working, Advantages, Construction, Working
Pattern & Its Applications pattern & Its Applications Disadvantages & Its Feeding Methods & It
Applications Applications

CATEGORIES RECENT COMMENTS

Communication K BALAJI on Simple Electronic Circuits for


Beginners
Electrical
Anny Arbert on Gyroscope Sensor Working
Electronics
and Its Applications
Project Ideas
Abhuday dangi on What is a UJT
Robotics Relaxation Oscillator – Circuit Diagram and
Applications
Technology
Satyadeo Vyas on Construction and
Working of a 4 Point Starter

Advertise With Us Disclaimer Report Violation Image Usage Policy

Copyright 2013 - 2025 © Elprocus

You might also like