SOLAR PV MODULE
144 HALF CUT TOPCON CELL
BIFACIAL DUAL GLASS 560-590W
TRANSITION TO A BRIGHTER TOMORROW
SMBB TECHNOLOGY
Better light trapping and current collection to
improve module power output and reliability.
PID Resistance
Excellent Anti-PID performance guarantee via
optimized mass-production process and
materials control.
Higher Power Output
Module power increases 5-25% generally,
bringing significantly lower LCOE and higher IRR.
Auto Bussing & Soldering Technology
Induction based Improved soldering quality
without pollution to module.
Enhanced Mechanical Load
Certified to withstand wind lead (2400 Pascal
and snow load (5400 Pascal).
M10 TOPCON Cell Module
M10-182mm wafer, Ideal for Ultra- large Power Plant
30 YEARS 12 YEARS
WARRANTY FOR PRODUCT WARRANTY
AVAILABLE IN ALL BLACK RANGE LINEAR POWER OUTPUT
C E R T I F I C AT I O N
IEC 61215, IEC 61730
IEC 61701, IEC 62716,
IEC 62853-1 & 2
IDEAL FOR
Residential Commercial Utility Off-grid
SOLAR PV MODULE
144 HALF CUT TOPCON CELL
BIFACIAL DUAL GLASS 560-590W
Model name: PEI-144(XXX)THGB-M10
ELECTRICAL CHARACTERISTICS(STC) TEMPERATURE CHARACTERISTICS
PE PE PE PE PE PE PE Pmax Temperature Coefficient -0.30%/°C
Module Type
TDG560 TDG565 TDG570 TDG575 TDG580 TDG585 TDG590
Maximum Power (Pmp) 560 565 570 575 580 585 590 Voc Temperature Coefficient -0.25%/°C
Open Circuit Voltage (Voc) 51.18 51.22 51.26 51.30 51.34 51.38 51.42 Isc Temperature Coefficient 0.04%/°C
Short Circuit Current (Isc) 13.40 13.50 13.61 13.71 13.83 13.93 14.04 Operating Temperature -40°C To +85°C
Maximum Power Voltage (Vmp) 43.91 43.95 43.99 44.03 44.07 44.11 44.15 Nominal Operating Cell Temperature 42 ± 3°C
Maximum Power Current (Imp) 12.76 12.86 12.96 13.06 13.17 13.27 13.37
Module Efficiency (%) 21.66 21.86 22.05 22.24 22.44 22.63 22.83
Power Tolerance 0 to +5W
Maximum System Voltage 1500V (UL & IEC) 16
Cell temp.=25°C
Maximum Series Fuse Rating 25 Amp 14
Incident Irrad = 1000W/m2 590.1W
* STC - lrradiance 1000 W/m², Module temperature 25°C and AM=1.5 Measuring Tolerance: ±3% 12
Incident Irrad = 800W/m2 460.7W
10
Current [A]
ELECTRICAL CHARACTERISTICS(NOTC) 8 Incident Irrad = 600W/m2 350.2W
6
PE PE PE PE PE PE PE Incident Irrad = 400W/m2 240.1W
Module Type
TDG560 TDG565 TDG570 TDG575 TDG580 TDG585 TDG590 4
Incident Irrad = 200W/m2 115.6W
Maximum Power (Pmp) 412 416 419 423 427 430 434 2
Open Circuit Voltage (Voc) 47.82 47.86 47.90 47.93 47.97 48.01 48.61 0
0 10 20 30 40 50 60
Short Circuit Current (Isc) 10.68 10.76 10.85 10.93 11.02 11.10 11.19 Voltage [V]
600
Maximum Power Voltage (Vmp) 40.74 40.78 40.82 40.86 40.89 40.93 40.97 Cell temp.=25°C 590.1W
Incident Irrad = 1000W/m2
Maximum Power Current (Imp) 10.11 10.19 10.27 10.35 10.43 10.51 10.59 500 Incident Irrad = 800W/m2
Incident Irrad = 600W/m2 460.7W
Module Efficiency (%) 15.95 16.09 16.23 16.38 16.52 16.66 16.76 Incident Irrad = 400W/m2
400 Incident Irrad = 200W/m2
Power [W]
* NOCT - Irradiance 800 W/m², AM 1.5, Ambient temperature 20°C and Wind speed 1m/s Measuring Tolerance: ±3% 350.2W
300
240.1W
PE PE PE PE PE PE PE 200
Gain(80+/-5)%
TDG560 TDG565 TDG570 TDG575 TDG580 TDG585 TDG590
115.6W
10% Power (Pmp) 616.0 621.50 627.0 632.5 638.0 643.5 649.0 100
20% Power (Pmp) 672.0 678.0 684.0 690.0 696.0 702.0 708.0 0
0
30% Power (Pmp) 728.0 734.5 741.0 747.5 754.0 760.5 767.0 10 20 30 40 50 60
Voltage [V]
• Bifacial gains depends on the power plant design and albedo of installation site
Measuring Tolerance: ±3%
• Power Bifaciality=Pmax(Rear)/Pmax(Front) are tested under STC
9
MECHANICAL SPECIFICATIONS
3.5
External Dimension 2278(±2mm)x 1134(±2mm)x35(±1mm)
14
Weight 34 (±3%)Kg
8
Drain Hole
8x3.5 – 16 No’s
Solar Cells 10 BB , Mono PERC-crystalline 91mm x182mm
l
9 5.1 Front Glass 2.0mm ARC Semi Tempered , HS Glass
65
Rear Cover 2.0mm Semi Tempered , HS Glass
14
Mounting Hole Frame Anodized Aluminium Alloy (Silver/Black)
65
9x14 – 8 No’s
Junction Box 3 Split, IP 68 Rated
D
Connector MC 4 Compatible
Earth Hole
10
Mounting Hole
7x10-4 No’s Common Ø5.1-2 No’s Mechanical Load 5400 Pa for Snow Load, 2400 Pa Wind Load
2278
ll
1400
990
400
2.1
Fire Performance TYPE 39 (UL 61730) Or Class C (IEC 61730)
Embossed
33
Earth
Split junction Box Symbol 4.0 mm2
Output Cable
35/30
A A
35 400 mm Length
FRAME PROFILE 35X33 MM (LONG) AND 35X18 MM (SHORT)
Section-AA
10.1
1088
18 PACKING CONFIGURATION
Container 40’HQ
35/30
18MM
B
Pieces per Pallet 31
65 B 35
135
1134 Section-BB Pallet per Container 20
10.1
All Dimension in ± 2mm Pieces per Container 620
FIRST YEAR DEGRADATION < 1.0% YEAR 2-30 POWER DEGRADATION <0.40%
For more details, please contact:
The specification and key features contained in this datasheet may deviate slightly from our actual
PREMIER ENERGIES GROUP products due to the on-going innovation and product enhancement, Premier Energies reserves the right
to make necessary adjustment to the information described herein at any time without further notice.
sales@[Link] | [Link]