UL202 RS232/RS485 Protocol
Version 2020-03
1. Protocol 14: Standard Protocol for RS232
(Default Protocol,Baud Rate:9600)
Liquid Level Real-time
Header Signal Software Hardware Valid End
Tilt
Version Minute Value (Value A, Value Temperature
Code Strength Code Code Signal Code
Angle
After Smooth) (ValueB)
*XD 4230 00 2067 99 0 0 2063 0578 27 #
0A
Liquid Level Value (Value A, After smooth)is generally used in measurement to make fuel report
Ascall Code :*XD,4190,00,2067,9900,2063,0578,270A#
a. 4230:
4 means protocol version : 4 means 14, which is default protocol version
23 means Firmware Version
0 means Hardware Version.
b. 2067 will be used as liquid level for GPS tracker server
c. 0578 is temperature of fuel, which is ( 578-400)*0.1=17.8 Celsius Degrees
d. 0A indicates the tilt angle of tank(0A is Hexadecimal , the value changed to decimal is
10)
1. Software Code
Software Code Explanation
0 Normal Data, everything OK
1 Power on, smooth value depends on real time value only
3 Weak signal, valid data quantity=0, smooth value will keep showing latest correct value
2. Hardware Code
Code Code
0 Normal.
1 Sensor Disconnect.
2 Sensor Fall off.
3 System Voltage anomaly.
UL202 RS232/RS485 Protocol
2. Protocol 16: Omnicom LLS protocol Only for RS485 or RS232
LLS protocol follow LLS protocol 07 commands, which output automatically.
Default Baud Rate: 19200
Default Net Address: 1
The data are HEX, which are transmitted with a lower byte ahead.
1) Data Output Format
2) Example & Description:
3E 01 07 14 DC 04 DC 04 67
3E Prefix
01 Default Network Address is 1
07 Default Operation code Command
14 Probe Temperature in Celsius Degree
DC04 Smooth Fuel Level Height (used for GPS Tracker/DVR)
It is lower byte ahead. DC 04 needs to switched to 04 DC, which means 1244 in
Decimal , unit 0.1mm.
So DC04 smooth value means 124.4mm height
DC04 Real time Fuel Level Height
67 Checksum
UL202 RS232/RS485 Protocol
3. Quick Guide for Installation:
Refer to 2020Jan Quick Guide for UL202 with New
firmware.pdf