0% found this document useful (0 votes)
38 views3 pages

New RS232 485 Data Protocol of UL202

The UL202 RS232/RS485 Protocol document outlines the standard protocols for RS232 and RS485 communication, including details on data formats, codes for software and hardware status, and examples of data output. It specifies default baud rates, network addresses, and the interpretation of various codes related to liquid level and temperature measurements. Additionally, it provides a quick installation guide reference for users with new firmware.

Uploaded by

offorma Nwafor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views3 pages

New RS232 485 Data Protocol of UL202

The UL202 RS232/RS485 Protocol document outlines the standard protocols for RS232 and RS485 communication, including details on data formats, codes for software and hardware status, and examples of data output. It specifies default baud rates, network addresses, and the interpretation of various codes related to liquid level and temperature measurements. Additionally, it provides a quick installation guide reference for users with new firmware.

Uploaded by

offorma Nwafor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

UL202 RS232/RS485 Protocol

Version 2020-03

1. Protocol 14: Standard Protocol for RS232


(Default Protocol,Baud Rate:9600)
Liquid Level Real-time
Header Signal Software Hardware Valid End
Tilt
Version Minute Value (Value A, Value Temperature
Code Strength Code Code Signal Code
Angle
After Smooth) (ValueB)

*XD 4230 00 2067 99 0 0 2063 0578 27 #


0A
Liquid Level Value (Value A, After smooth)is generally used in measurement to make fuel report
Ascall Code :*XD,4190,00,2067,9900,2063,0578,270A#

a. 4230:
4 means protocol version : 4 means 14, which is default protocol version
23 means Firmware Version
0 means Hardware Version.
b. 2067 will be used as liquid level for GPS tracker server
c. 0578 is temperature of fuel, which is ( 578-400)*0.1=17.8 Celsius Degrees
d. 0A indicates the tilt angle of tank(0A is Hexadecimal , the value changed to decimal is
10)

1. Software Code

Software Code Explanation

0 Normal Data, everything OK


1 Power on, smooth value depends on real time value only

3 Weak signal, valid data quantity=0, smooth value will keep showing latest correct value

2. Hardware Code
Code Code
0 Normal.

1 Sensor Disconnect.
2 Sensor Fall off.
3 System Voltage anomaly.
UL202 RS232/RS485 Protocol
2. Protocol 16: Omnicom LLS protocol Only for RS485 or RS232

LLS protocol follow LLS protocol 07 commands, which output automatically.


Default Baud Rate: 19200
Default Net Address: 1
The data are HEX, which are transmitted with a lower byte ahead.
1) Data Output Format

2) Example & Description:


3E 01 07 14 DC 04 DC 04 67
3E Prefix
01 Default Network Address is 1
07 Default Operation code Command
14 Probe Temperature in Celsius Degree
DC04 Smooth Fuel Level Height (used for GPS Tracker/DVR)
It is lower byte ahead. DC 04 needs to switched to 04 DC, which means 1244 in
Decimal , unit 0.1mm.
So DC04 smooth value means 124.4mm height
DC04 Real time Fuel Level Height
67 Checksum
UL202 RS232/RS485 Protocol

3. Quick Guide for Installation:

Refer to 2020Jan Quick Guide for UL202 with New


firmware.pdf