0% found this document useful (0 votes)
239 views5 pages

Tinned Copper Conductor Technical Data

The document provides technical data sheets for two types of low voltage power cables and a tinned coated soft drawn bare copper conductor. It includes specifications such as conductor size, electrical characteristics, and construction details, complying with international standards like IEC 60228 and IEC 60502-1. The cables are designed for specific applications with defined temperature limits, resistance values, and current carrying capacities.

Uploaded by

Awais Ali Shah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
239 views5 pages

Tinned Copper Conductor Technical Data

The document provides technical data sheets for two types of low voltage power cables and a tinned coated soft drawn bare copper conductor. It includes specifications such as conductor size, electrical characteristics, and construction details, complying with international standards like IEC 60228 and IEC 60502-1. The cables are designed for specific applications with defined temperature limits, resistance values, and current carrying capacities.

Uploaded by

Awais Ali Shah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TECHNOLOGY DEPARTMENT

TECHNICAL DATA SHEET


FOR
Tinned Coated Soft Drawn Bare Copper Conductor

Product ID: 14111011


Conductor description:
150 mm2 - Tinned Coated Soft Drawn Bare Copper Conductor

Tinned coated soft drawn bare copper conductor with round shape non compacted class 2
stranded, complying with IEC 60228.

1.0 Conductor Dimensions Data:


1.1 Conductor Size: 150 mm2
1.2 Nominal number of wires in the conductor: 37
1.3 Overall diameter (Approx.): 15.4 mm
1.4 Standard length on reel: 1000 m
1.5 Tolerance of length: 5 %
1.6 Reel dimensions: 1100* mm
*Reel dimensions may be varied according to actual length.

2.0 Electrical Characteristics:


2.1 Maximum Conductor DC resistance @ 20 0C: 0.126 Ω/km

3.0 Specifications:
3.1 The conductor is generally according to international standard
- IEC 60228 & ASTM B33

4.0 Drawing:

Description 150 mm², Tinned Coated Soft Drawn Bare Copper Conductor, Round Non-Compacted
1 Tinned Copper Wire
2 Tinned Copper Conductor

Inquiry No: EP-1000339 Product ID: 14111011 Date: 27/08/2023


1
TECHNOLOGY DEPARTMENT

TECHNICAL DATA SHEET


LOW VOLTAGE POWER CABLE

Cable Description:
Cu / XLPE / PVC (FR) 1kV 1X150 mm2 RM
IEC 60502-1 FR-IEC 60332-3.24, outer sheath UV resistant

Design and Construction Data:


Reference Manufacturing Standards IEC/BS EN 60228, IEC 60502-1
Max. Permissible Continuous Conductor Temp °C 90
Max. Conductor Short Circuit Temp for 5 Seconds °C 250
Rated Voltage ' Uo / U ' kV 0.6 / 1.0
Number of Conductors x Cross-Section mm2 1 x 150
Conductor Material & Shape Copper & Stranded Class 2
non-compacted Round Shape
Insulation Material XLPE
Conductor Nominal Insulation Thickness mm 1.40
Insulation Color GREEN
Outer Sheath Material PVC - ST2, flame retardant
Colour of Outer Sheath YELLOW WITH GREEN STRIPES
Approximate Cable Overall Diameter mm 21.2
Electrical Data:
Max Conductor DC resistance @ 20 °C ohms/km 0.1240
Max Conductor AC resistance @ 90 °C Two Cables ohms/km 0.1600
Max Conductor AC resistance @ 90 °C Three Cables/Trefoil ohms/km 0.1606
Formation
Max Conductor Short Circuit Current @ 1 Second kA 21.45
Current Carry Capacity
Laid in air @ 40 °C Ambient Temperature
Free In Flat Shape A 461
Free In Trefoil Shape A 367
In Pipes A 269
Laid in Ground
Direct Laid In Flat Shape A 385
Direct Laid In Trefoil Shape A 363
Laid In Duct A 290
Laid in Ground with the following conditions:
Ambient Ground Temperature: 35 °C
Depth of laying in ground: 0.5 m
Soil Thermal Resistivity: 1.2 °K.m/W
Additional Data:
Maximum pulling Tension kN 7.50
Maximum side wall pressure kN/m 44.1
Minimum Bending Radius mm 170
The Cable shall meet all Test requirements of: IEC/BS EN 60228, IEC 60502-1, IEC 60332-3.24
Packing Data:
Drum Type Non-Returnable
Length of Cable per drum (± 5%) m 1000
Drum Dimensions "Height x Width" (Approx.) m 1.2 x 1.01
Gross Weight (Approximate without Lagging) kg 1,558

Inquiry No.: EP-1000339 eanwar 27/08/2023

Product ID: 19925825 Page 1 / 2


TECHNOLOGY DEPARTMENT

TECHNICAL DATA SHEET


LOW VOLTAGE POWER CABLE

Cable Marking:
BAHRA CABLES CO. KSA 1 X 150 mm² Cu / XLPE / PVC 600 / 1000 V IEC 60502-1 FR IEC 60332-3.24
Manufacturing Year - Meter marked
Cable Drawing

1 2

Description Cu / XLPE / PVC (FR) 1kV 1X150 mm2 RM Approx. Diameter


1 Core
Stranded Copper Conductor with round shape 15.22
XLPE insulated 18.02
2 PVC-FR Outer Sheathing 21.22

Inquiry No.: EP-1000339 eanwar 27/08/2023


Product ID: 19925825 Page 2 / 2
TECHNOLOGY DEPARTMENT

TECHNICAL DATA SHEET


LOW VOLTAGE POWER CABLE

Cable Description:
Cu / XLPE / PVC (FR) 1kV 1X120 mm2 RM
IEC 60502-1 FR-IEC 60332-3.24, outer sheath UV resistant

Design and Construction Data:


Reference Manufacturing Standards IEC/BS EN 60228, IEC 60502-1
Max. Permissible Continuous Conductor Temp °C 90
Max. Conductor Short Circuit Temp for 5 Seconds °C 250
Rated Voltage ' Uo / U ' kV 0.6 / 1.0
Number of Conductors x Cross-Section mm2 1 x 120
Conductor Material & Shape Copper & Stranded Class 2
non-compacted Round Shape
Insulation Material XLPE
Conductor Nominal Insulation Thickness mm 1.20
Insulation Color GREEN
Outer Sheath Material PVC - ST2, flame retardant
Colour of Outer Sheath YELLOW WITH GREEN STRIPES
Approximate Cable Overall Diameter mm 19.3
Electrical Data:
Max Conductor DC resistance @ 20 °C ohms/km 0.1530
Max Conductor AC resistance @ 90 °C Two Cables ohms/km 0.1966
Max Conductor AC resistance @ 90 °C Three Cables/Trefoil ohms/km 0.1971
Formation
Max Conductor Short Circuit Current @ 1 Second kA 17.16
Current Carry Capacity
Laid in air @ 40 °C Ambient Temperature
Free In Flat Shape A 409
Free In Trefoil Shape A 326
In Pipes A 237
Laid in Ground
Direct Laid In Flat Shape A 345
Direct Laid In Trefoil Shape A 327
Laid In Duct A 258
Laid in Ground with the following conditions:
Ambient Ground Temperature: 35 °C
Depth of laying in ground: 0.5 m
Soil Thermal Resistivity: 1.2 °K.m/W
Additional Data:
Maximum pulling Tension kN 6.00
Maximum side wall pressure kN/m 39.0
Minimum Bending Radius mm 154
The Cable shall meet all Test requirements of: IEC/BS EN 60228, IEC 60502-1, IEC 60332-3.24
Packing Data:
Drum Type Non-Returnable
Length of Cable per drum (± 5%) m 1000
Drum Dimensions "Height x Width" (Approx.) m 1.2 x 1.01
Gross Weight (Approximate without Lagging) kg 1,280

Inquiry No.: EP-1000339 eanwar 27/08/2023

Product ID: 19928587 Page 1 / 2


TECHNOLOGY DEPARTMENT

TECHNICAL DATA SHEET


LOW VOLTAGE POWER CABLE

Cable Marking:
BAHRA CABLES CO. KSA 1 X 120 mm² Cu / XLPE / PVC 600 / 1000 V IEC 60502-1 FR IEC 60332-3.24
Manufacturing Year - Meter marked
Cable Drawing

1 2

Description Cu / XLPE / PVC (FR) 1kV 1X120 mm2 RM Approx. Diameter


1 Core
Stranded Copper Conductor with round shape 13.87
XLPE insulated 16.27
2 PVC-FR Outer Sheathing 19.27

Inquiry No.: EP-1000339 eanwar 27/08/2023


Product ID: 19928587 Page 2 / 2