The Innova-Switch is a versatile device that functions as both a mass flow switch for liquids and gases and a point level switch for liquid level detection, operating within a wide temperature range of -100 F to +850 F. It features fast response times, durable construction with 316L stainless steel, and is designed for low maintenance in demanding applications. The device is CE, CENELEC, and CSA approved, making it suitable for various industrial environments.

Uploaded by

MarioOliveirapt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views2 pages

FS420

The Innova-Switch is a versatile device that functions as both a mass flow switch for liquids and gases and a point level switch for liquid level detection, operating within a wide temperature range of -100 F to +850 F. It features fast response times, durable construction with 316L stainless steel, and is designed for low maintenance in demanding applications. The device is CE, CENELEC, and CSA approved, making it suitable for various industrial environments.

Uploaded by

MarioOliveirapt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Innova-Switch ™


Single Channel
Mass Flow or
Point Level Switch

Features

 Mass flow Switch for the

detection of the mass flow rate

of liquids and gases

 Point level switch for liquid level

detection

 Wide operating temperature range


Description
-100 F to +850 F (-70 C to 458 C)
o o o o

 Flow Switch range of 0.01 to 5 fps S ierra Instruments’ Innova-Switch represents the
liquids and 0.1 to 500 fps gases State-of-the-art in gaseous and liquid flow switching or
 Level Switch switches on level liquid level control and continues the Sierra tradition
change 0.03 inch of providing the highest quality mass flow meters and
 Fast flow switch response time controllers in the industry.

of 0.5 to 10 seconds (media Flow and level detection is accomplished by using a


dependent) high-resolution thermal differential technique. The sensor

 Level switch response time consists of a pair of matched Resistance Temperature


Detectors (RTD’s). One RTD is self-heated using a
of 0.1 to 1 second of wetting (media
dependent) constant DC current. The other RTD is unheated and
provides an accurate process temperature reference. The
 CE, CENELEC and CSA approvals
thermal differential created between the reference and
the heated RTD pair is a function of the density and/or
velocity of the media with which the sensor is in contact.
The sensor and wetted parts are of durable 316L
stainless steel, all welded construction with no moving
parts. The switch is easy to install and adjust, giving
reliable, low maintenance performance in the most
demanding applications.

For information online...


[Link]
The information contained herein is subject to change without notice.
Go to [Link] for the most current information.
Dimensional Specifications Operating Specifications
Operating Temperature:
Process: -70 to 200 C (-100 F to 390 F) standard. Medium T to 300 C (572 F)
o o o o o o

optional
Hi T to 485 C (850 F)
o o

Electronics: -40 C to 60 C (-40 F to 140 F). Optional remote electronics for use
o o o o

in medium and Hi T environments


Operating Pressure: to 3000 psia (207 bar)
Input Power: 115 VAC, 50/60Hz standard. 230 VAC, 50/60Hz optional,
24VDC optional. 3.1 Watt maximum
Output: 5A. 250 VAC. DPDT with fail safe capability

Physical Specifications
Wetted Materials: 316 SS standard. Hastelloy, Monel, Inconel or other
materials optional
Enclosure: Explosion Proof; NEMA 3,4X,7,9. CSA, FM, UL, CENELEC and
EECS approved
Process Connection: 0.75” MNPT standard. 0.5” and larger MNPT and vari-
Performance Specifications ous other process connections such as sanitary and flanges optional
Operating Range: Insertion Length: 2.0” standard. 0.5” or greater optional
Flow Switch: Adjustable flow rate (feet per second-fps), typical:0.01 to 5.0 fps Approvals: CE, CSA, CENELEC Class 1 Div 1 Groups B,C,D
liquids and 0.1 to 500 fps gases
Level Switch: Switch on level change of 0.03 inch
Response Time:
Flow Switch: 0.5 to 10 seconds (media dependent)
Level Switch: 0.1 to 1 second (media dependent)
615-LS32
Repeatability: +/- 1% of setpoint (Flow) or 1/32” (0.8mm) Level
Stability: Drift <0.5% from calibrated setpoint over a range of +/-50F.
Temperature compensated through entire range.
Ordering Information

PARENT MODEL NUMBER


615-LS32 Innova-Switch LEVEL Switch
615-FS42 Innova-Switch FLOW Switch

AGENCY APPROVALS NX Non-explosion proof switch


CS CSA approved
CN CENELEC approved

PROCESS CONNECTIONS RA1 Raised face flange 150# 1”


3A1 1.5” Sanitary with 3A stamp RA2 Raised face flange 150# 2”
075 0.75” MNPT (STD) RB1 Raised face flange 300# 1”
050 0.50” MNPT RA1 Raised face flange 300# 2”
100 1” MNPT SPL Special
SENSOR MATERIAL HC Hastalloy C
S6 316SS (STD) IO Iconel 600
S4 304SS MN Monel
SL 304L SS A2 Alloy 20
HB Hastalloy B SM Special Material
INSERTION LENGTH 000.00 0.5” to 120” in .25” increment
002.00 2.00” (STD)

POWER INPUT 24D 24 VDC


110 110 VAC
220 220 VAC

CONFIGURATION RE Remote Electronics


LE Local Electronics (STD)

SPECIAL OPTIONS MT Medium T


00 No special options HT Hi T
CB Calibration Required RTD RTD output
EN Extended Neck TO Thermocouple output
XW Explosion Proof window CA Additional cable
V1 Variable insertion CE CE approval
LT Live (hot) tap
DS Double Sided 615 B IH 8/10