0% found this document useful (0 votes)
6 views3 pages

GSA Report Kayong Utara

The document provides solar resource data for Kayong Utara, Indonesia, including annual averages for direct normal irradiation (DNI), global horizontal irradiation (GHI), and specific photovoltaic power output (PVOUT). It details the average air temperature and optimal tilt for PV modules, along with monthly and hourly irradiation profiles. The report is generated by Solargis under contract to The World Bank, offering insights for solar power potential in the region.

Uploaded by

yoksna 212
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views3 pages

GSA Report Kayong Utara

The document provides solar resource data for Kayong Utara, Indonesia, including annual averages for direct normal irradiation (DNI), global horizontal irradiation (GHI), and specific photovoltaic power output (PVOUT). It details the average air temperature and optimal tilt for PV modules, along with monthly and hourly irradiation profiles. The report is generated by Solargis under contract to The World Bank, offering insights for solar power potential in the region.

Uploaded by

yoksna 212
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Kayong Utara

-01.225848°, 109.225109°
Kayong Ut ara, Kalimant an Barat , Indonesia
T ime zone: UT C+07, Asia/Pont ianak [WIB]

access_time Report generated: 21 Dec 2024

SITE INFO

Map data Per year Map

Specific phot ovolt aic PVOUT


1412.8 kWh/kWp
power out put specific

Direct normal irradiat ion DNI 1126.0 kWh/m 2

Global horizont al
GHI 1747.8 kWh/m 2
irradiat ion

Diffuse horizont al
DIF 877.8 kWh/m 2
irradiat ion

Global t ilt ed irradiat ion at


GT I opta 1756.8 kWh/m 2
opt imum angle

Opt imum t ilt of PV


OPTA 5/ 0 °
modules
500 m
Air t emperat ure T EMP 25.8 °C 3000 ft Leaflet | Satellite tiles © Esri

Terrain elevat ion ELE N/A


PVOUT map

Horizon and sunpath

300 km
300 mi Leaflet | PVOUT map © 2024 Solargis

© 2024 The World Bank Group Kayong Utara 1/3


PV ELECTRICITY AND SOLAR RADIATION

Annual averages Average hourly profiles


Direct normal irradiat ion Direct normal irradiat ion [Wh/m 2]

1141.4
Jan Feb Mar Apr

kWh/m 2 per year

0 0 0 0
Monthly averages 0 12 24 0 12 24 0 12 24 0 12 24

Direct normal irradiat ion May Jun Jul Aug

150

0 0 0 0
[kWh/m2 ]

100
0 12 24 0 12 24 0 12 24 0 12 24

Sep Oct Nov Dec


50

0
0 0 0 0
0 12 24 0 12 24 0 12 24 0 12 24
n

ct
ay

ov
l
ar

ec
g
Ju
Ap

Ju

Au
Fe

Se
Ja

O
M

N
M

UT C+07

Average hourly profiles


Direct normal irradiat ion [Wh/m 2]

Jan Fe b Mar Apr May Jun Jul Aug Sep Oc t Nov De c


0-1
1-2
2-3
3-4
4-5
5-6
6-7 20 20 46 82 108 76 50 34 49 73 95 49
7-8 113 127 167 205 201 196 169 145 132 157 183 142
8-9 188 213 244 301 296 291 267 234 215 227 251 201
9 - 10 256 298 302 368 391 386 363 331 294 287 300 237
10 - 11 304 365 380 417 460 446 440 413 363 343 334 274
11 - 12 337 406 406 432 490 486 492 451 398 355 346 305
12 - 13 344 420 426 434 497 509 535 485 428 349 346 305
13 - 14 312 388 391 396 464 504 513 461 398 302 306 267
14 - 15 249 313 290 352 404 441 455 396 305 238 254 218
15 - 16 185 241 256 272 316 340 352 294 208 165 177 151
16 - 17 103 148 164 176 199 220 239 168 93 72 89 87
17 - 18 27 42 42 23 25 30 52 22 6 3 6 11
18 - 19
19 - 20
20 - 21
21 - 22
22 - 23
23 - 24
S um 2,439 2,977 3,115 3,459 3,852 3,926 3,929 3,435 2,890 2,571 2,687 2,247

© 2024 The World Bank Group Kayong Utara 2/3


GLOSSARY

Acro nym Full name Unit T ype o f use


DIF Diffuse horizontal irradiation kWh/m², MJ/m² Average yearly, monthly or daily sum of diffuse horizontal irradiation (©
2024 Solargis)
DNI Direct normal irradiation kWh/m², MJ/m² Average yearly, monthly or daily sum of direct normal irradiation (© 2024
Solargis)
ELE Terrain elevation m, ft Elevation of terrain surface above/below sea level, processed and
integrated from SRT M-3 data and related data products (SRT M v4.1 ©
2004 - 2024, CGIAR-CSI)
GHI Global horizontal irradiation kWh/m², MJ/m² Average annual, monthly or daily sum of global horizontal irradiation (©
2024 Solargis)
GT I Global tilted irradiation kWh/m², MJ/m² Average annual, monthly or daily sum of global tilted irradiation (© 2024
Solargis)
GT I_opta Global tilted irradiation at optimum angle kWh/m², MJ/m² Average annual, monthly or daily sum of global tilted irradiation for PV
modules fix-mounted at optimum angle (© 2024 Solargis)
OPT A Optimum tilt of PV modules ° Optimum tilt of fix-mounted PV modules facing towards Equator set for
maximizing GT I input (© 2024 Solargis)
PVOUT _total Total photovoltaic power output kWh, MWh, GWh Yearly and monthly average values of photovoltaic electricity (AC)
delivered by the total installed capacity of a PV system (© 2024 Solargis)
PVOUT _specific Specific photovoltaic power output kWh/kWp Yearly and monthly average values of photovoltaic electricity (AC)
delivered by a PV system and normalized to 1 kWp of installed capacity
(© 2024 Solargis)
T EMP Air temperature °C, °F Average yearly, monthly and daily air temperature at 2 m above ground.
Calculated from outputs of ERA5 model (© 2024 ECMWF, post-
processed by Solargis)

ABOUT

This pdf report (t he “Work”) is aut omat ically generat ed from t he Global Solar At las online app (ht t ps://globalsolarat las.info/), prepared by
Solargis under cont ract t o The World Bank, based on a solar resource dat abase t hat Solargis owns and maint ains. It provides t he est imat ed
solar resource, air t emperat ure dat a and pot ent ial solar power out put for t he select ed locat ion and input paramet ers of a phot ovolt aic (PV)
power syst em.

Copyright © 2024 The World Bank


1818 H St reet NW, Washingt on DC 20433, USA

The World Bank, comprising t he Int ernat ional Bank for Reconst ruct ion and Development (IBRD) and t he Int ernat ional Development
Associat ion (IDA), is t he commissioning agent and copyright holder for t his Work, act ing on behalf of The World Bank Group. The Work is
licensed by The World Bank under a Creat ive Commons At t ribut ion license (CC BY 4.0 IGO) wit h a mandat ory and binding addit ion (please
refer t o t he GSA websit e for full t erms and condit ions of use ht t ps://globalsolarat las.info/support /t erms-of-use).

The World Bank Group disclaims all warrant ies of any kind relat ed t o t he provision of t he Work.

The Work is made available solely for general informat ion purposes. Neit her t he World Bank, Solargis nor any of it s part ners and affiliat es
hold t he responsibilit y for t he accuracy and/or complet eness of t he dat a and shall not be liable for any errors, or omissions. It is st rongly
advised t hat t he Work be limit ed t o use in informing policy discussions on t he subject , and/or in creat ing services t hat bet t er educat e
relevant persons on t he viabilit y of solar development in areas of int erest . As such, neit her t he World Bank nor any of it s part ners on t he
Global Solar At las project will be liable for any damages relat ing t o t he use of t he Work for financial commit ment s or any similar use cases.
Solargis has done it s ut most t o make an assessment of solar climat e condit ions based on t he best available dat a, soft ware, and knowledge.

Sources: Solar dat abase and PV soft ware © 2024 Solargis

© 2024 The World Bank Group Kayong Utara 3/3

You might also like