Process Flow Chart of ETP, Capacity: 135m3/hr.
05
-
Waste Water Inlet
(a) pH : 10.6
(b) COD : 754mg/l Bar Screen
08/10/2021
(c) BOD : 350mg/l
(d) TSS : 175mg/l
Rotary Screen
(e) TDS : 3560mg/l
-
(f) DO : 1.2mg/l
(g) Temp. : 42 Degree
Aeration Blower
Collection Tank
Engr. Md. Suruz Zaman
Equalization Tank
Increase & Decrease
Filter Back wash DO & Temp.
Water Re-cycle
Engr. Md. Mewanul Kabir
Engr. Md. Maynul Islam
Flash Mixing PAC
Alum
Dosing Platform
Flocculation
Poly
Tank H2O2
Waste Water Treatment Plant for Anowara Knit Composite Limited
Decrease of
Filter Press
COD & TDS
Primary Acid
Sludge Out Clarifier
Biological Tank
Process Flow Chart for ETP
(a) pH : 7-8
(b) DO : 1-3 mg/l
(c) MLSS : 2800-3500mg/
(d) Temp. : 35-40 Degree
RAS
Holding Tank
Sludge
Secondary
Sludge Out Clarifier Aeration Blower
Innovative Engineers
Nabinagor,Savar, Dhaka, Bangladesh.
Office: Sena Shoping Complex,
CONSULTANT NAME:
Air Line
Filter Feed Tank
Filter unit
MGF ACF
Filter Back wash
Outlet
Anowara Knit Composite Limited
Mulayed, Dhaka - Mymensingh Hwy, Mawna Union
CLIENT NAME & ADDRESS
Post Aeration
Air Line (a) pH : 6-9
(b) COD : 200mg/l
(c) BOD : 50mg/l
(d) TSS : 200mg/l
(e) TDS : 2100mg/l
(f) DO : 4.8-8mg/l
Treat Water (g) Temp. : 36 Degree